The dependence of binocular contrast sensitivities on binocular single vision in normal and amblyopic human subjects

Size: px
Start display at page:

Download "The dependence of binocular contrast sensitivities on binocular single vision in normal and amblyopic human subjects"

Transcription

1 Journal of Physiology (2002), 540.2, pp DOI: /jphysiol The Physiological Society The dependence of binocular contrast sensitivities on binocular single vision in normal and amblyopic human subjects A. S. Hood and J. D. Morrison Institute of Biomedical and Life Sciences, West Medical Building, University of Glasgow, Glasgow G12 8QQ, UK We have measured monocular and binocular contrast sensitivities in response to medium to high spatial frequencies of vertical sinusoidal grating patterns in normal subjects, anisometropic amblyopes, strabismic amblyopes and non-amblyopic esotropes. On binocular viewing, contrast sensitivities were slightly but significantly increased in normal subjects, markedly increased in anisometropes and esotropes with anomalous binocular single vision (BSV) and significantly reduced in esotropes and exotropes without BSV. Application of a prismatic correction to the strabismic eye in order to achieve bifoveal stimulation resulted in a significant reduction in contrast sensitivity in esotropes with and without anomalous BSV, in exotropes and in non-amblyopic esotropes. Control experiments in normal subjects with monocular viewing showed that degradative effects of the prism occurred only with high prism powers and at high spatial frequencies, thus establishing that the reduced contrast sensitivities were the consequence of bifoveal stimulation rather than optical degradation. Displacement of the image of the grating pattern by 2 deg in normal subjects and anisometropes by a dichoptic method to simulate a small angle esotropia had no effect on the contrast sensitivities recorded through the companion eye. By contrast, esotropes showed similar reductions in contrast sensitivity to those obtained with the prism experiments, confirming a fundamental difference between subjects with normal and abnormal ocular alignments. The results have thus established a suppressive action of the fovea of the amblyopic eye acting on the companion, non-amblyopic eye and indicate that correction of ocular misalignments in adult esotropes may be disadvantageous to binocular visual performance. (Resubmitted 18 October 2001; accepted 18 January 2002) Corresponding author J. D. Morrison: Institute of Biomedical and Life Sciences, West Medical Building, University of Glasgow, Glasgow G12 8QQ, UK. jdm1u@udcf.gla.ac.uk Amblyopia is a relatively common condition in man, with an incidence of %, in which the visual acuity through one eye is subnormal despite the absence of any overt pathologies (von Noorden, 1990). It arises as a result of deprivation of adequate visual stimulation during early childhood and once established is, in many cases, irreversible. The major causes are occlusion, squint (strabismus) or unequal refraction between the two eyes (anisometropia). Strabismus falls into two main categories: an inward deviation of one eye (esotropia) or, less frequently, an outward deviation (exotropia). Deviations in other directions arise but are not considered further. An important but unanswered question concerns the quality of vision that amblyopes have on binocular viewing. When visual performance is measured as the contrast sensitivity for the just supra-threshold detection of vertically orientated, sinusoidal grating patterns of different spatial frequencies, the contrast sensitivities are enhanced on binocular viewing compared with monocular viewing by some 40 % (Campbell & Green, 1965a; Ross et al. 1985; Pardhan & Gilchrist, 1990). The situation in amblyopes who are combining visual information from a normal eye and an amblyopic eye is far from clear. With respect to reaction times for detection of a grating pattern, those for binocular viewing have been shown to be no different from those for monocular viewing with the non-amblyopic eye, thus implying that the contribution from the amblyopic eye has been disregarded (Levi et al. 1979). In testing this assumption, the type of binocular vision must be taken into account. Simple anisometropic amblyopes have normal binocular single vision (BSV), which is not the case in strabismics. On binocular viewing, esotropes and exotropes are characterized by suppression of the visual input from the misaligned eye so that BSV is absent. However, in esotropes with a small to moderate angle deviation and in microtropes who are defined as having esotropia of 5 deg or less, abnormal retinal correspondence may develop between the fovea of the normal eye and the extrafoveal region aligned with the visual axis of the deviating eye; in these cases, anomalous BSV may develop (Lyle & Wybar, 1967).

2 608 A. S. Hood and J. D. Morrison J. Physiol We have, therefore, undertaken contrast sensitivity measurements in different categories of amblyopes with particular regard being paid to the status of their BSV i.e. whether present, absent or anomalous. First, binocular contrast sensitivities were compared with those for monocular viewing. Since all types of amblyopes show a loss of contrast sensitivity at high spatial frequencies (Hess & Howell, 1977; Leguire et al. 1989), we carried out our determinations over the high spatial frequency limb of the contrast sensitivity function. Second, bifoveal viewing in strabismics was effected by a prism that compensated for the angle of squint and the effects on contrast sensitivity were determined. It was then ascertained with dichoptic viewing whether a shift of the retinal image in one eye affected the contrast sensitivities through the other eye in normal subjects. Our results have shown that binocular contrast sensitivities depend on the presence or absence of BSV rather than the type of amblyopia. METHODS Subjects A total of 42 subjects participated in the experiments. Each subject gave his/her informed consent to participation in the study, which conformed to the requirements of the Declaration of Helsinki and the Western District Ethics Committee of the Greater Glasgow Health Board, UK. Visual assessments For each subject, the following assessments were carried out. Visual acuity. This was determined as the best Snellen acuity for each eye, with additional spherical or cylindrical refraction if necessary. The subjective refraction was then confirmed objectively by retinoscopy using a streak retinoscope at a working distance of 1 m. Fixation pattern. The uniocular fixation pattern was determined by ophthalmoscopy in which the subject was requested to fixate the central graticule of the ophthalmoscope. By observation of the small glint of light reflected by the foveola, fixation was assessed as being foveal if the glint was located centrally or extra-foveal if located non-centrally. For the latter, the deviation in degrees was determined from the graticule circles. It was also noted whether the fixation was steady, unsteady or, in the presence of eccentric fixation, wandering (Duke Elder & Wybar, 1973). Extra-ocular muscle balance. Non-strabismic subjects may exhibit heterophoria, which is an imbalance in eye position in the absence of a visual image and is compensated for on normal viewing. By contrast, strabismic subjects exhibit heterotropia, which is an error of alignment during normal viewing. The direction and magnitude of heterophoria and heterotropia were determined with the prism and cover test carried out with the subject fixating at the viewing distance employed in the experiments. The principle of this test is that when one eye is covered, since there is no visual input to guide fixation, that eye will assume its resting position. Hence, on rapid removal of the cover, the eye will be seen to move from its resting position in order to fixate the visual scene. Temporal movement on removal of the cover is indicative of esophoria since the eye must have assumed a nasally directed resting position. The converse is true for exophoria. In practice, this test is carried out alternating the cover over each eye in turn. By placing the appropriate power of prism in front of the dominant eye in normal subjects or the nonamblyopic eye in amblyopes and an alternate cover test carried out, no movement of the eyes is seen. In normal subjects, the prism power equals the magnitude of heterophoria and in strabismics it equals the magnitude of heterotropia and any associated heterophoria. In the cases of microtropia without identity, the magnitude of the manifest deviation was determined by the simultaneous prism and cover test (Dale, 1982). The reason for this is that microtropes who possess anomalous BSV fall into two groups: microtropes with identity who use the parafoveal point which serves as a pseudofovea in both monocular and binocular viewing and microtropes without identity who use a different parafoveal point in monocular and binocular viewing. In the simultaneous prism and cover test, a prism positioned baseout is placed in front of the squinting eye while the non-amblyopic eye is occluded. When the angle of microtropia has been neutralized by the prism, no movement of this eye occurs behind the prism on occlusion of the non-amblyopic eye. This test gives the magnitude of microtropia. BSV status. The presence or absence of BSV was determined by application of three tests. The Bagolini Striated Lornette generates a line of light at 45 deg in one eye and 135 deg in the other eye. In cases of normal or anomalous BSV, a saltire is perceived, the central part of which may or may not be absent in anomalous BSV, whereas in the absence of BSV one diagonal of the saltire is completely absent (Lyle & Wybar, 1967). The macular Worth four-dot test consists of two laterally placed green spots, a superior red spot and an inferior white spot. The subject views through a red filter in one eye and a green filter in the other. If normal or anomalous BSV is present, the subject reports the presence of the four spots of light. If central suppression is present in one eye, then the number of spots reported is that seen by the other eye viz. three spots with the green filter or two spots with the red filter. The Four Dioptre Prism Reflex Test involves placing a prism of power 4 (resulting in ~2 deg deviation) in front of the subject s eye in order to deflect the incoming light rays from a point light source: this leads to a conjugate movement in both eyes as the eye behind the prism re-establishes foveal fixation. In subjects with normal BSV, this is then followed by a compensatory movement of the nonprism eye in order to regain fusion of the image while, when central suppression is present, no subsequent movement is observed (Irvine, 1944; Romano & von Noorden, 1969). Accommodation. The amplitude of accommodation was determined monocularly by adding concave lenses in order to stimulate an increase in accommodation that is equal and opposite to the concave lens. The amplitude of accommodation was the largest power of concave lens with which the subject still possessed best Snellen acuity. Horizontal pupil diameter was estimated for distance viewing with the millimetre rule on the handle of the Romanes occluder. Stimulus display The stimulus display consisted of a vertical sinusoidal grating pattern generated on a Tektronix 606B monitor (Tektronix UK Ltd, Bracknell, UK) with a P31 phosphor of peak emission at 520 nm. Fixation was guided by a centrally placed small black spot. The display had a surround of similar hue and luminance to the display. The timebase of the monitor was provided by the ramp output of a Tektronix 5103 oscilloscope running at 0.5 ms div _1, which was fed into the X input of the monitor. A uniform green raster was generated by feeding a 770 khz triangular wave into the Y input of the monitor. Sine wave

3 J. Physiol Binocular contrast sensitivities 609 modulation of the raster horizontally across the monitor was obtained by feeding a variable sine wave from a Farnell LFP1 oscillator (Farnell Instruments Ltd, Wetherby, UK) into the Z input of the monitor. A stationary sinusoidal grating pattern was obtained by using the trigger output of the oscillator to trigger the Tektronix 5103 oscilloscope which was also used to monitor the frequency and amplitude of the Z modulation sine wave. A calibration graph between the contrast of the sinusoidal grating pattern and the Z modulation voltage was determined psychophysically by the method of Campbell & Green (1965b). The luminance of the display, measured with a UDT Optometer (Optilas Ltd, Milton Keynes, UK), was 8.4 cd m _2 and the room illumination was 1 mcd. Contrast sensitivity measurements These were made by the ascending method which provides values very similar to those derived psychometrically based on 50 % detection (Morrison & Reilly, 1986). Starting with a uniform display, the subject increased the display contrast via a 10-turn potentiometric control unit until the grating pattern was just detectable, at which point the peak-to-peak Z modulation voltage was measured. This was repeated six times and a mean contrast threshold was calculated. The reciprocal of this value is the contrast sensitivity. Initially, the subject carried out practice runs at 10, 20 and 30 cycles deg _1 before undertaking the main experiments which were as follows. Binocular and monocular contrast sensitivities. In order to compare the binocular contrast sensitivities with those for monocular viewing, determinations were undertaken in normal subjects over the range 10_40 cycles deg _1 in 5 cycles deg _1 steps in pseudo-random order for, first, viewing monocularly with the right eye, second, with the left eye and, third, for binocular viewing. For monocular viewing, the companion eye was occluded. In amblyopic subjects, monocular viewing was first with the normal eye and then with the amblyopic eye. This was followed by binocular viewing which, in anisometropes, was bifoveal and, in strabismics, was foveal with the normal eye and extra-foveal with the strabismic eye. In these subjects, an additional spatial frequency of 8 cycles deg _1 was tested since vision at higher spatial frequencies with the amblyopic eye was curtailed. Control monocular experiments. The possibility that the presence of illumination per se in the companion eye may have affected the contrast sensitivities of the test eye was investigated by comparing monocular viewing with the companion eye occluded against the companion eye viewing through a diffuser. The diffuser, which consisted of medium duty polythene stretched over a trial lens blank, was effective in degrading the highest contrast with minimal loss of luminance. Six contrast threshold readings taken in two groups of three readings were obtained for each viewing condition at 10, 20 and 30 cycles deg _1. Prismatic correction in strabismics. The effect of bifoveal viewing was determined in strabismics by application of a full diameter prism of appropriate power and orientation, which neutralized the angle of heterotropia as determined with the prism and cover test or simultaneous prism and cover test. The power of the prism was divided between both eyes and generally did not exceed 8 D. In microtropes without identity, the angle of deviation neutralized was equal to the difference between the eccentric point in the microtropic eye used on binocular viewing and the pseudofovea used by that eye on monocular viewing. For ease of terminology, this is still referred to as bifoveal viewing. In these experiments binocular contrast sensitivities were determined over the range 8 40 cycles deg _1. Dichoptic viewing in normal subjects. For comparison with the results from bifoveal viewing in strabismic amblyopes, normal subjects undertook binocular viewing in which the image in one eye was displaced eccentrically from the fovea. This could not be achieved prismatically since an external prism would induce a compensatory translation of the eye in order to maintain bifoveal viewing and hence binocular fusion. Thus, in order to effect stimulation of non-corresponding retinal points, dichoptic viewing of the grating pattern was undertaken. The grating pattern which had a subtense of 2 deg was viewed through an optical system consisting of a 2 inch (50.8 mm) beamsplitter and front silvered mirrors as shown in Fig. 1. Positioned at 2 deg to the left of the centre of the grating pattern was a green light-emitting diode (LED) of subtense 5 min arc. When the right eye fixated on the LED, the grating pattern was located 2 deg temporally, thus Figure 1. Schematic representation of the dichoptic viewing apparatus This shows the path from the cathode ray tube (CRT) display and light emitting diode (LED) to the left eye (LE) and right eye (RE) of the subject who is positioned at the lower margin of the figure, looking upwards. The beams are divided by the beamsplitter BS. The reflected beams are further reflected through 90 deg by the front silvered mirror M1. The right eye may thus view either both the LED and CRT or, after occlusion of the CRT beam by the movable occluder O2, the LED beam alone. Of the beams transmitted by the beamsplitter, the LED beam is occluded by the fixed occluder O1. The CRT beam is reflected twice through 90 deg by the front silvered mirrors M2 and M3. The two CRT beams are equalized by inclusion of the neutral density filter ND. Mirror M1 is mounted on a rotatable stage to allow adjustment of its orientation.

4 610 A. S. Hood and J. D. Morrison J. Physiol falling on the nasal retina and simulating an esotropia of that magnitude. The left eye and right eye grating pattern beams were equalized by inclusion of the appropriate neutral density filter in the path of one beam. Contrast sensitivities were then determined over the range 5 40 cycles deg _1 for: (i) left eye foveal viewing of the grating pattern, (ii) left eye foveal viewing of the grating pattern together with right eye foveal viewing of the green LED in order to determine whether the superimposed image of the LED affected the left eye contrast sensitivities, and (iii) left eye foveal viewing of the grating pattern together with right eye foveal viewing of the green LED and right eye eccentric viewing of the grating pattern, in order to determine whether the eccentric grating pattern affected the left eye contrast sensitivities. These experiments were also performed on simple anisometropic amblyopes in whom foveal viewing of the grating pattern was made with the non-amblyopic eye and eccentric viewing of the grating pattern was made with the amblyopic eye. Dichoptic viewing in strabismics. In order to test the repeatability of the results for bifoveal viewing in strabismics, the dichoptic apparatus was also employed in a number of these subjects. Monocular contrast sensitivities were first determined for foveal viewing of the grating pattern with the non-amblyopic eye. The use of the green LED to guide fixation of the strabismic eye was not practicable in these subjects since they exerted a constant magnitude of heterotropia. Therefore, the apparatus was first arranged for bifoveal viewing for a normal subject without the LED. After the angle of heterotropia in the strabismic subject had been determined, the apparatus was adjusted in order to effect bifoveal stimulation in that subject. This procedure was followed for each strabismic subject. Control prism experiments. In order to determine whether the prisms used for prismatic correction in strabismics had any degradative effect on contrast sensitivity, control experiments were undertaken by placing a prism in front of one eye which then executed a compensatory translation to maintain foveal fixation. Contrast sensitivities were determined over the range 8 40 cycles deg _1 for normal viewing and with prisms of power 2, 4, 6, 8, 10 and 12 D. The prism was placed base-out in cases of esophoria and base-in in cases of exophoria. Binocular and monocular contrast sensitivities, prismatic correction in strabismics and control prism experiments were carried out at a viewing distance of 2.86 m. Control monocular experiments, dichoptic viewing in normal subjects and dichoptic viewing in strabismics were carried at 2.43 m. The display subtense was arranged to be 2 deg for both viewing distances. The total combined experimental time for binocular and monocular contrast sensitivities and prismatic correction in strabismics was 3 4 h, for control monocular experiments the total time was h, and for dichoptic viewing in normal subjects, dichoptic viewing in strabismics and control prism experiments the total combined time was 2 3 h. The experiments were carried out at a measured pace with frequent breaks. Statistical analysis Analyses of the data were performed post hoc at the end of each group of experiments with the Minitab 11 (Minitab Ltd, Coventry, UK) statistical package (Ryan & Joiner, 1994). Depending on the subject group, the difference between better eye and poorer eye viewing, binocular and better eye viewing, viewing with and without a prism and, in the dichoptic viewing experiments, viewing in the absence and presence of the eccentrically located grating pattern was calculated at each spatial frequency. The dependence of the calculated difference on spatial frequency was tested by linear regression analysis. In all cases, the differences in contrast sensitivity were not related to spatial frequency (R 2 < 56 %, P >0.1). This allowed the calculation for each subject of a mean overall difference which was the difference in contrast sensitivity between the two viewing states averaged over the spatial frequency range. These values were expressed as a percentage of the reference contrast sensitivities, e.g. better eye viewing in the comparison between binocular and better eye viewing. Within each group of subjects, these values were compared against zero, i.e. application of Student s paired t test. Between different groups of subjects, the values were compared with a two sample t test. Values are given as the mean ± S.E.M. The relationships between logarithm contrast sensitivity and spatial frequency and between contrast sensitivity differences and decimal Snellen acuity were analysed by linear regression analysis. Statistical significance was taken when P <0.05. RESULTS Initially, the subject groups were based on the criteria that normal vision required a Snellen acuity of 6/6 or better, corrected if necessary, while amblyopia was defined as 6/9 or poorer. All amblyopic subjects had uniocular amblyopia of varying severity. Normal subjects had foveolar fixation in both eyes and normal BSV. Simple anisometropic amblyopes also had foveolar fixation in both eyes and normal BSV together with a refractive error difference between eyes of at least 1.00 D in any meridian without the presence of microtropia. Microtropes exhibited an esotropia of no more than 10 D, the presence of superimposed heterophoria, extra-foveolar fixation and central suppression in the microtropic eye, and well established anomalous BSV. Esotropic amblyopes with anomalous BSV consisted of small to moderate angle esotropes who exhibited an absence of heterophoria, foveolar fixation in each eye for monocular viewing, and anomalous BSV. Esotropic and exotropic amblyopes without BSV exhibited heterotropia, showed an absence of BSV and the state of fixation of the amblyopic eye, i.e. whether foveolar or eccentric, was not critical. Non-amblyopic esotropes and exotropes exhibited Snellen acuity of 6/6 or better in both eyes, heterotropia of constant magnitude and no clinical evidence of BSV as indicated by the presence of constant central and peripheral suppression. However, after completion of the contrast sensitivity measurements, several anomalies became apparent. Two of the original 11 normal subjects showed a mean overall difference in contrast sensitivity between eyes of 40 and 43 % despite having Snellen acuities of 6/5: these were significantly different from the distribution for the remaining nine subjects (P <0.001). On the basis that these subjects could not be considered normal, they were excluded from the normal group. In two non-amblyopic esotropes, mean overall differences between eyes of 44 and 51 % suggested that the poorer eye was amblyopic and these subjects were incorporated into the group of

5 J. Physiol Binocular contrast sensitivities 611 Figure 2. Comparison of binocular and monocular contrast sensitivities Comparisons of the mean logarithm contrast sensitivities against the spatial frequency of the sinusoidal grating pattern display for binocular viewing (0), viewing through the better or non-amblyopic eye (1) and viewing through the poorer or amblyopic eye (9) for representative subjects. For each subject, the change in contrast sensitivity averaged over the range of spatial frequencies is shown for the poorer eye (PE) and binocular viewing (BIN) compared with the better eye taken as 100 %. A, normal subject with BSV: PE = _17 %, BIN= +11 %. B, anisometropic amblyope with BSV: PE = _65 %, BIN= +28 %. C, esotropic amblyope with anomalous BSV: PE = _40 %, BIN= +37 %. D, esotropic amblyope without BSV: PE = _44 %, BIN= _26 %. E, exotropic amblyope without BSV: PE = _56 %, BIN= _29 %. F, nonamblyopic esotrope without BSV: PE = _18 %, BIN= _14 %. All changes for PE and BINare significant (P <0.05). The S.E.M. is smaller than the symbol size and symbols falling on the x axis denote that that spatial frequency was not detected.

6 612 A. S. Hood and J. D. Morrison J. Physiol Table 1. Clinical data for revised groups of subjects Subject category n Age (years) LE or NE RE or AE Diff (Sph Eq) Tropia Normal + BSV /4 6/5 6/4 6/ DS 0 Anisometropes + BSV /4 6/6 6/9 6/ DS 0 Esotropes + absv /4 6/6 6/9 6/ DS 4 6 D Esotropes _ BSV /5 6/6 6/9 6/ DS 6 30 D Exotropes _ BSV /4 6/9 6/4 6/ DS D Non-amblyp Eso _ BSV /4 6/6 6/4 6/ DS D BSV, binocular single vision (+ present, _ absent); absv, anomalous binocular single vision; LE, left eye; NE, normal eye; RE, right eye; AE, amblyopic eye; Diff (Sph Eq), difference in refraction in spherical equivalents; Tropia, magnitude of esotropia or exotropia in prism dioptres. esotropic amblyopes without BSV. Similarly, two nonamblyopic exotropes whose mean overall differences were 41 and 44 % were incorporated into the group of exotropic amblyopes without BSV. Finally, on the basis of the similarity of the magnitude of esotropia and the contrast sensitivity results, the microtropes and esotropic amblyopes with anomalous BSV were combined into one group. The revised groups are shown in Table 1. In addition, all subjects had adequate accommodation to focus the displays and there were no abnormalities in pupil diameters, which were broadly equal within the precision of the measurements. Monocular and binocular contrast sensitivities Over the range of spatial frequencies studied, logarithm contrast sensitivity declined monotonically until the high spatial frequency cut-off was reached (Fig. 2A). For each of the nine normal subjects, the relationship was well described by a straight line of negative slope which was statistically significant (R 2 > 87 %, P <0.02). In terms of the mean overall contrast sensitivity, one eye performed better than the companion eye with a range of mean differences over the spatial frequency range studied of 6 29 %. For the group as a whole, the mean overall difference between the better eye and the poorer eye was 18 ± 3 %, which was statistically significant (P =0.002). The amblyopic groups, as might be expected, showed a much more pronounced reduction between the better eye and the amblyopic eye, reflecting the downwards shift of the contrast sensitivity function (Fig. 2B E). The mean overall reduction in anisometropes was 45 ± 9 % (range _8 to _88 %); in esotropes with anomalous BSV, it was 53 ± 7 % (range _26 to _87 %); in esotropes without BSV, it was 60 ± 7 % (range _31 to _51 %); and in exotropes without BSV, it was 57 ± 1 % (range _41 to _87 %). In each case the difference was statistically significant (P =0.001). In the two non-amblyopic esotropes, the mean overall reductions were 18 and 22 % (Fig. 2F), which were similar to the values for the normal subjects. A further outcome was that the non-amblyopic eye of our amblyopic subjects did not perform as well as the better eye of our normal subjects, which was inferred from the following analysis. For each subject the contrast sensitivity values were summed over the range cycles deg _1 and the values for the normal group were normalized so that they gave a mean value of 100 % for the group. This normalization factor was then applied to the results of the amblyopic subjects, which are shown in Table 2. The mean value for the 30 amblyopes was 76.1 %, which was significantly different from that of the normal group (P =0.008). Hence, these results indicate that the nonamblyopic eye of amblyopes was, in fact, not normal. With respect to the comparison between binocular and better eye viewing, the normal group showed an overall mean increase of 13 ± 5 % (range 3 49 %) which, while small, was nonetheless statistically significant (P =0.02) (Fig. 2A). Both the anisometropes and esotropes with anomalous BSV showed much larger increases in the mean overall contrast sensitivity of 35 ± 7 % (range +6 to +77 %) and 38 ± 11 % (range +15 to +67 % with one subject at _26 %), respectively (P <0.01) (Fig. 2B and C). The enhancement present in the anisometropic group was significantly higher than that of the normal group (P =0.03), as was the enhancement shown by the esotropes with anomalous BSV after the omission of one subject who showed a reduction (P =0.01). By contrast, the groups without BSV showed different results. Binocular contrast sensitivities showed a mean overall reduction of 14 ± 3 % (range _5 to _26 %) in esotropes without BSV and 26 ± 6 % (range _11 to _41 %) in exotropes without BSV (Fig. 2D and E). These reductions, which were significant (P =0.003), were not related to the depth of amblyopia expressed as the decimal Snellen acuity (R 2 = 0 %, P=0.71). The two non-amblyopic esotropes showed a mean overall increase of 2 % and a decrease of 14 % (Fig. 2F). When the binocular contrast sensitivities over the range cycles deg _1 were normalized and summed, the amblyopes with BSV collectively showed a mean value which was 20.5 % less than that for the normal group (Table 2, P=0.025). Hence, while the binocular contrast sensitivities of amblyopes with BSV showed a marked increased over those of their non-amblyopic eye alone, they still did not attain the values of normal subjects.

7 J. Physiol Binocular contrast sensitivities 613 Table 2. Percentage change in total contrast sensitivity Subject category n Better eye (%) P Binocular (%) P Normal + BSV ± ± 5.9 Anisometropes + BSV ± ± Esotropes + absv ± ± Esotropes _ BSV ± ± Exotropes _ BSV ± ± All amblyopes ± Amblyopes with BSV ± Comparison of contrast sensitivities of amblyopic groups against the normal group whose values were normalized to give a mean of 100 %. Values are expressed as means ± S.E.M. and P values were obtained with Student s two-sample t test. BSV, binocular single vision (+ present, _ absent); absv, anomalous binocular single vision. Control monocular experiments These experiments were undertaken to determine whether an isoluminant uniform display presented to the companion eye affected the contrast thresholds of the test eye. Comparisons were made at 10, 20 and 30 cycles deg _1 between the contrast sensitivities when the companion eye viewed through the diffuser against when the companion eye was occluded. In two normal subjects, two esotropes without BSV and an exotrope without BSV, no significant differences occurred at any of the three spatial frequencies tested (P >0.05). The mean overall differences between the diffuser and occluder contrast sensitivities were +2.0 and +5.5 % for the two normal subjects, +7.8 and +4.3 % for the two esotropes and _1.5 % for the exotrope. Prismatic correction in strabismics The application of the appropriate prismatic correction to effect bifoveal stimulation in strabismics on binocular viewing caused a significant reduction in contrast sensitivity compared with natural binocular viewing in these groups (Fig. 3A D). In the esotropes with anomalous BSV, the mean overall reduction was 25 ± 4 % (range _7 to _39 %) (P =0.0002) and, in the esotropes without BSV, it was 27 ± 5 % (range _4 to _44 %) (P =0.003) (Fig. 3A and B). Three exotropes without BSV showed a reduction (range _6 to _44 %) while one exotrope showed an increase of 8 % giving a mean reduction of 15 ± 11 % which was not significant (P =0.26) (Fig. 3C). The two non-amblyopic esotropes without BSV showed reductions of 33 and 53 % Figure 3. Bifoveal viewing experiments Comparisons of the mean logarithm contrast sensitivities against the spatial frequency of the sinusoidal grating pattern display between normal binocular viewing (1) and binocular viewing with bifoveal stimulation effected by prismatic correction (8) for representative subjects. The percentage difference between binocular viewing with the prism (BIN+ D) and binocular viewing is given for each subject. A, esotropic amblyope with anomalous BSV: (BIN+ D) = _37 %. B, esotropic amblyope without BSV: (BIN+ D) = _44 %. C, exotropic amblyope without BSV: (BIN+ D) = _44 %. D, non-amblyopic esotrope without BSV: (BIN+ D) = _33 %. The reductions are all significant (P <0.05). The S.E.M. is smaller than the symbol size and symbols falling on the x axis denote that that spatial frequency was not detected.

8 614 A. S. Hood and J. D. Morrison J. Physiol Figure 4. Control prism experiments Mean logarithm contrast sensitivity against the spatial frequency of the sinusoidal grating pattern display between normal viewing with the better eye (1) and viewing through a prism of stated power (9) for a representative subject. *Statistical significance (P <0.05). The S.E.M. is smaller than the symbol size and symbols falling on the x axis denote that that spatial frequency was not detected. Figure 5. Dichoptic viewing experiments Comparisons of the logarithm contrast sensitivities against the spatial frequency of the sinusoidal grating pattern display between normal monocular viewing of the display with the better or non-amblyopic eye and foveal viewing of the green LED in the other eye (1 in A D) and monocular viewing of the display with the better or non-amblyopic eye and foveal viewing of the green LED together with eccentric viewing of the grating display by the other eye (8 in A D). The percentage difference as a result of additionally viewing the eccentric display (ECC) is given for each subject. A, normal subject: ECC = +2 % (not significant). B, anisometropic amblyope: ECC = _1 % (not significant). C, esotropic amblyope with anomalous BSV: ECC = _25 % (P <0.01). D, esotropic amblyope without BSV: ECC = _33 % (P <0.01). The S.E.M. is smaller than the symbol size and symbols falling on the x axis denote that that spatial frequency was not detected.

9 J. Physiol Binocular contrast sensitivities 615 (Fig. 3D). Hence, out of the 22 strabismics in whom bifoveal stimulation was effected, 21 showed showed a reduction in contrast sensitivity. This reduction was not related to the depth of amblyopia expressed as the decimal Snellen acuity (R 2 = 0 %, P =0.48). Control prism experiments Monocular contrast sensitivities were determined for the better eye of four normal subjects for viewing through prisms of increasing power. Comparison of the contrast sensitivities at each spatial frequency with and without the prism showed that there were no significant changes over the range 8 35 cycles deg _1 with prisms of power 2, 4, 6 and 8 D (P >0.05). For the subject shown in Fig. 4 A D, no significant changes occurred at 8 25 cycles deg _1 with 10 and 12 D (P >0.05) while significant reductions did occur at cycles deg _1 (P<0.05). In the group data, with prisms of 10 and 12 D, no significant changes occurred at 8 15 cycles deg _1 (P>0.05) while significant reductions did occur at cycles deg _1 (P<0.05). This indicated that degradation did occur, but only with the largest prism powers at the higher spatial frequencies. Dichoptic viewing in normal and strabismic subjects Since prisms could not be used to create an eccentrically positioned image in normal subjects, recourse was made to dichoptic stimulation in which one eye fixated on the green LED so that the grating pattern was positioned 2 deg temporally. Contrast sensitivities were determined monocularly over the range 5 35 cycles deg _1 in six normal subjects. The range of spatial frequencies was slightly truncated compared with previous experiments due to the reduced luminance of the CRT display resulting from division of the beam. With the left eye viewing the grating pattern, the superimposition of the green LED seen by the right eye had no effect on the monocular contrast sensitivities of the left eye alone (P =0.43). Comparison of the former set of results with contrast sensitivities for left eye foveal viewing of the grating pattern and right eye foveal viewing of the green LED with the eccentrically located grating pattern also showed no significant change. The mean overall difference between the results with and without the eccentrically located grating pattern in the right eye was _1 ± 1 % (P =0.17). In two anisometropes, Figure 6. Summary of results Overall percentage change in contrast sensitivity averaged over the spatial frequencies studied. Columns show mean ± S.E.M. except where n =2 where mean only is shown. A, differences between binocular and better/nonamblyopic eye monocular viewing in normal subjects (Normal, n =9), anisometropes with BSV (Aniso, n =9), esotropes with anomalous BSV (Eso + BSV, n =9), esotropes without BSV (Eso _ BSV, n =7), exotropes without BSV (Exo _ BSV, n =4) and non-amblyopic esotropes without BSV (nonameso, n =2). B, difference between bifoveal viewing effected by prismatic correction and normal binocular viewing (Prism Binocular _ Binocular) for the same heterotropes as in A. C, differences between normal monocular viewing with the better/non-amblyopic eye plus foveal viewing of the green LED together with eccentric viewing of the grating display by the other eye and normal monocular viewing with the better/non-amblyopic eye plus foveal viewing of the green LED in the other eye (Eccentric _ Monocular) for six normal subjects, two anisometropes, two esotropic amblyopes with anomalous BSV and three esotropic amblyopes without BSV.

10 616 A. S. Hood and J. D. Morrison J. Physiol the mean overall contrast sensitivity change was +2 and _1 %. These results, which are illustrated in Fig. 5A and B, showed that the eccentrically positioned grating pattern was without effect on contrast sensitivities recorded through the companion eye. By contrast, under conditions of bifoveal stimulation, two esotropic amblyopes with anomalous BSV showed mean overall reductions in contrast sensitivity of 23 and 25 % (Fig. 5C), while three esotropic amblyopes without BSV showed reductions of 33, 33 and 50 % (Fig. 5D). Clearly, the presence of the grating pattern image on the fovea of the strabismic eye caused a marked reduction in contrast sensitivity, thus confirming the results of the prism experiments. DISCUSSION Our measurements of contrast sensitivities over the high spatial frequency limb of the contrast sensitivity function have produced two clear cut results. The first, which is summarized in Fig. 6A, shows that the presence of BSV was associated with binocular facilitation in nine normal subjects and in 17 out of 18 amblyopes with normal or anomalous BSV. Furthermore, the amount of binocular facilitation was significantly greater in both anisometropes and esotropes with anomalous BSV than in normal subjects. The second result, which is summarized in Fig. 6B, is that in esotropic amblyopes with and without BSV, non-amblyopic esotropes without BSV and exotropes without BSV, bifoveal stimulation effected by prismatic correction caused a marked reduction in contrast sensitivities compared with normal binocular viewing. Subjects with BSV or anomalous BSV On binocular viewing by normal subjects, the mean increase in contrast sensitivity of 13 % compared with the better eye was less than previous reports of 40 % (Campbell & Green, 1965a; Ross et al. 1985; Pardhan & Gilchrist, 1990). The value reported by Campbell & Green (1965a) is for comparison against the mean value, while Ross et al. (1985) and Pardhan & Gilchrist (1990) did not state the basis of their comparisons. Against the better eye, our result is comparable with the 17 % increase in contrast sensitivity recorded by Marshall et al. (2001) and the 10 % reduction in reaction time recorded by Blake et al. (1980). A possible confounding factor in the interpretation of our results was that monocular contrast sensitivities were obtained with the companion eye occluded so that the presence of a bright field in this eye on binocular viewing may have had a depressive action on the binocular contrast sensitivities. However, since monocular contrast sensitivities were not affected when the companion eye viewed through a diffuser compared with when the eye was occluded, this can be excluded. This is in agreement with previous results for contrast sensitivities (Campbell & Green, 1965a; Pardhan & Gilchrist, 1990) and reaction times for detection of a grating pattern (Harwerth et al. 1980). The increases in binocular contrast sensitivities of 35 and 38 % in anisometropes and esotropes with anomalous BSV have no precedents in the literature. A small number of microtropes has been shown to have a small improvement in visual acuity on binocular viewing while a single anisometrope showed none (Sireteanu et al. 1981). In another study, a small number of anisometropes was shown to have an absence of binocular summation at low spatial frequencies (Holopigian et al. 1986). By contrast, in patients with Duane syndrome who had reduced abduction but attained and maintained BSV by adopting an abnormal head posture, binocular summation was 32 % when compared with the better eye (Marshall et al. 2001); this complements the present results very well. Amblyopes without BSV The absence of BSV was associated with binocular inhibition which occurred in all 11 heterotropes without BSV. Whether a reduction also occurs in non-amblyopic esotropes without BSV cannot be resolved from our sample of two subjects. Since monocular contrast sensitivities were the same irrespective of whether the companion eye was occluded or illuminated, which is consistent with the reaction time data of Levi et al. (1979), this confirms that the binocular inhibition required the presence of spatial contrast and not just illumination. Pardhan & Gilchrist (1990) have demonstrated an inhibitory action on monocular contrast sensitivities of a positive defocusing lens of 2 3 DS worn in front of the companion eye in normal subjects. This, however, is unlikely to be related to the inhibition present in amblyopes since it can be accounted for by the 180 deg phase shift (i.e. contrast reversal) of the defocused image and the subsequent combination of out-of-phase images (Hopkins, 1955). Nor is the binocular inhibition a straightforward manifestation of suppression as conventionally understood. Normally, suppression is exerted by the normal eye on the input from the strabismic eye, though not in the reverse direction (Travers, 1938; Sireteanu, 1982). The suppression affects the fovea and the region of nasal retina aligned with the visual axis of esotropes and may encompass the intervening retina (Lyle & Wybar, 1967) while, in exotropes, the suppression area may consist of the entire temporal retina of the deviating eye (Jampolsky & Schlor, 1955). While the operation of suppression, as conventionally understood, accounts for the absence of binocular enhancement in heterotropes without BSV, it does not explain the reduction of contrast sensitivities to below those of the non-amblyopic eye. This may be regarded as suppression of the non-amblyopic eye by the amblyopic eye, which is a new finding. An additional result of importance is that, in all types of amblyope, the non-amblyopic eye had subnormal contrast sensitivities (Table 2) which confirms the previous

11 J. Physiol Binocular contrast sensitivities 617 reports of Leguire et al. (1990) and Holopigian et al. (1991) though not of Hess & Howell (1977) who concluded that the non-amblyopic eye was normal. Bifoveal viewing All heterotropes, regardless of whether BSV was present or absent, showed marked reductions in binocular contrast sensitivities on binocular viewing. An effect of prismatic degradation in our experiments may be excluded since this occurred only for prism powers of at least 10 and 12 D and, then, only at higher spatial frequencies (Fig. 4). The only group which might have been affected were the two nonamblyopic esotropes who required 18 and 40 D and who detected spatial frequencies of up to 30 cycles deg _1. Further evidence, which excludes prismatic degradation as an important factor, is that the reduction in contrast sensitivity was also reproduced in the dichoptic viewing experiments in five esotropes who had previously undertaken the prism experiments (Fig. 6C). Hence, it may be asserted with confidence that bifoveal stimulation results in diminished contrast sensitivities that may be inferred to arise from an inhibitory action of the neural input of the fovea of the misaligned eye. In these cases, the fovea of the misaligned eye may be deemed to be non-corresponding to the fovea of the normal eye, irrespective of whether or not the individual had anomalous BSV. This is in marked contrast to normal subjects and anisometropes, both of whom possess normal BSV. In these groups, there was no reduction in contrast sensitivity on binocular viewing when one grating pattern was located eccentrically, which indicates that the eccentric pattern was essentially disregarded. This is consistent with the lack of effect of an illuminated field in one eye on the contrast sensitivities through the other eye. Hence, the binocular inhibition present on bifoveal viewing is specific to the presence of ocular misalignment. While this again represents the operation of suppression of the non-amblyopic eye by the amblyopic eye, it would be premature to view it as conventional suppression working in the reverse direction. Conventional suppression is inversely related to the depth of amblyopia (Holopigian et al. 1988), which is not the case with suppression phenomenon we have described (see Results). The model In order to explain our results, a model is presented in Fig. 7, which shows the proposed neural projections in normal and amblyopic subjects. The question as to whether the differences in inputs arise from reduced numbers of neurones or from reduced firing rates is deferred until later. The basis of the neural projections to both left and right visual cortices is that the grating pattern which subtended 2 deg is viewed by the central fovea from which 50 % nasal retinal ganglion cells project temporally and 50 % temporal retinal ganglion cells project nasally within in a vertical strip of visual field of width 1 deg (Bunt et al. 1977). Additionally, callosal fibres projecting between the V1 V2 boundary extend into V1 by mm (Van Essen & Zeki, 1978), which corresponds to about 0.1 deg (Daniel & Whitteridge, 1961), leading to further bilateral representation of the central foveal projections. For normal viewing (Fig. 7A), convergence of the left and right eye inputs onto the binocular integrating centre occurs at visuotopically corresponding locations in the left and right cortices which, while shown as primary visual cortex, may reside in prestriate cortex. The strong excitatory inputs (shown in blue) are proposed to be balanced by mutual inhibition (shown in red) so that the overall binocular facilitation is rather modest. A difference arises in anisometropes for whom the excitatory inputs are shown to be slightly reduced for the normal eye and markedly reduced for the amblyopic eye (Fig. 7B). The mutual inhibition is proposed to be of high threshold so that it may be reduced or, as shown in Fig. 7B, absent. The net effect is enhancement of binocular facilitation compared with normal. This is not the state of affairs in esotropes without BSV (Fig. 7C) in whom the stimulated part of the right eye (nasal retina) is shown as projecting to a different binocular integrating centre (dotted circle) in the left hemisphere, since this is a non-corresponding retinal area. This input is proposed to weakly stimulate its own binocular integrating centre while exerting appreciable inhibition on the integrating centre innervated by the left eye. This would account for the inhibition recorded on binocular viewing. A comparable arrangement may be proposed for exotropes without BSV with the difference that, since the image falls on the temporal retina which projects ipsilaterally, the inhibitory interactions occur in the right hemisphere. In esotropes with anomalous BSV, a new retinal correspondence has been established so that the nasal retina of the right (esotropic) eye has an excitatory projection to the same binocular integrating centre as the left eye (Fig. 7D). As in the case of anisometropes, the mutual antagonism mechanism is proposed to be subthreshold so that binocular facilitation occurs. The projections activated during the deviation of the image in the right eye either prismatically or dichoptically are represented by R*. In normal subjects and anisometropes, the image that falls on the nasal retina projects to a binocular integrating centre in the contralateral hemisphere, which is proposed to be essentially disconnected from the binocular integrating centre for foveal viewing (Fig. 7A and B). By contrast, in both esotropes without BSV and esotropes with anomalous BSV, stimulation of the fovea of the right eye is proposed to lead to inhibition of the binocular integrating centre for foveal viewing (Fig. 7C and D). This is a marked difference from normal subjects and anisometropes. Comparisons with psychophysical data Steady viewing of a high contrast display is a well established method of investigating the characteristics of

Normal and amblyopic contrast sensitivity functions in central and peripheral retinas

Normal and amblyopic contrast sensitivity functions in central and peripheral retinas Normal and amblyopic contrast sensitivity functions in central and peripheral retinas Joseph Thomas Contrast sensitivity functions (CSF's)for temporally modulated sine wave gratings were established at

More information

OPTO 5320 VISION SCIENCE I

OPTO 5320 VISION SCIENCE I OPTO 5320 VISION SCIENCE I Monocular Sensory Processes of Vision: Color Vision Mechanisms of Color Processing . Neural Mechanisms of Color Processing A. Parallel processing - M- & P- pathways B. Second

More information

THE OUTCOME OF STRABISMUS SURGERY IN CHILDHOOD EXOTROPIA

THE OUTCOME OF STRABISMUS SURGERY IN CHILDHOOD EXOTROPIA THE OUTCOME OF STRABISMUS SURGERY IN CHILDHOOD EXOTROPIA J. M. KEENAN and H. E. WILLSHAW Birmingham SUMMARY The results of squint surgery in 42 children with primary, non-paralytic, childhood are analysed.

More information

DEVELOPMENT OF NORMAL BINOCULAR VISION IN EARLY

DEVELOPMENT OF NORMAL BINOCULAR VISION IN EARLY Brit. J. Ophthal. (1965) 49, 154 DEVELOPMENT OF NORMAL BINOCULAR VISION IN EARLY CONVERGENT STRABISMUS AFTER ORTHOPHORIA* BY From the University Eye Clinic, Parma, Italy A fundamental difference exists,

More information

August [KZ 0811] Sub. Code: 6041 B.Sc. OPTOMETRY DEGREE EXAMINATION. THIRD YEAR Paper I BINOCULAR VISION Q.P. Code :

August [KZ 0811] Sub. Code: 6041 B.Sc. OPTOMETRY DEGREE EXAMINATION. THIRD YEAR Paper I BINOCULAR VISION Q.P. Code : August 2011 [KZ 0811] Sub. Code: 6041 DEGREE EXAMINATION. Paper I BINOCULAR VISION Q.P. Code : 806041 Time : Three hours Maximum : 100 marks Answer All questions. I. Elaborate on : (3 x 10 = 30) 1. Development

More information

Think Outside the Box. Strabismus & Amblyopia. Prescribing. Amblyopia 5/9/2017. Goals of today s lecture: Kacie Monroe, OD, FCOVD. Peripheral Movement

Think Outside the Box. Strabismus & Amblyopia. Prescribing. Amblyopia 5/9/2017. Goals of today s lecture: Kacie Monroe, OD, FCOVD. Peripheral Movement Think Outside the Box Strabismus & Kacie Monroe, OD, FCOVD Goals of today s lecture: Define success in treatment Determine the best path to get there Spoiler: it may not be what you think Provide specific

More information

Paediatric Ophthalmology Assessment. Justin Mora 2017

Paediatric Ophthalmology Assessment. Justin Mora 2017 Paediatric Ophthalmology Assessment Justin Mora 2017 History Visual developmental milestones Aware of people in the room, reaching for objects, following toys, alignment should be central and stable

More information

BINOCULAR DEPTH PERCEPTION IN SMALL-ANGLE

BINOCULAR DEPTH PERCEPTION IN SMALL-ANGLE Brit. J. Ophthal. (1959) 43, 662. BINOCULAR DEPTH PERCEPTION IN SMALL-ANGLE STRABISMUS* BY E. J. NAYLOR AND A. STANWORTH Department of Ophthalmology, University of Manchester MEASUREMENTS of the binocular

More information

Author: Ida Lucy Iacobucci, 2015

Author: Ida Lucy Iacobucci, 2015 Author: Ida Lucy Iacobucci, 2015 License: Unless otherwise noted, this material is made available under the terms of the Creative Commons Attribution-NonCommercial-Share Alike 4.0 License: http://creativecommons.org/licenses/by-nc-sa/4.0/

More information

BINOCULAR MECHANISMS IN SMALL-ANGLE

BINOCULAR MECHANISMS IN SMALL-ANGLE Brit. J. Ophthal. (1959) 43, 648. BINOCULAR MECHANISMS IN SMALL-ANGLE STRABISMUS* BY A. STANWORTH AND DAPHNE DA CUNHA University of Manchester and Manchester Royal Eye Hospital THE purpose of treatment

More information

SPATIAL FREQUENCY (CPD) Contrast evoked potentials in strabismic and anisometropic amblyopia. DENNIS M. LEVI 10; 6 :

SPATIAL FREQUENCY (CPD) Contrast evoked potentials in strabismic and anisometropic amblyopia. DENNIS M. LEVI 10; 6 : Number 6 Reports 571 Contrast evoked potentials in strabismic and anisometropic amblyopia. DENNIS. VI AND RONALD S. HARWERTH. Steady-state visual evoked potentials were elicited by the appearance I disappearance

More information

A contrast paradox in stereopsis, motion detection and vernier acuity

A contrast paradox in stereopsis, motion detection and vernier acuity A contrast paradox in stereopsis, motion detection and vernier acuity S. B. Stevenson *, L. K. Cormack Vision Research 40, 2881-2884. (2000) * University of Houston College of Optometry, Houston TX 77204

More information

RETINOSCOPY HANDBOOK FOR CLINICIANS

RETINOSCOPY HANDBOOK FOR CLINICIANS RETINOSCOPY HANDBOOK FOR CLINICIANS Author: Sarah Wassnig B.Optom(OcTher), MPH New England College of Optometry created this handbook for the use of Orbis International trainees. This publication is the

More information

Differences in vernier discrimination for gratings between strabismic and anisometropic amblyopes. Dennis M. Levi and Stanley Klein

Differences in vernier discrimination for gratings between strabismic and anisometropic amblyopes. Dennis M. Levi and Stanley Klein Differences in vernier discrimination for gratings between strabismic and anisometropic amblyopes Dennis M. Levi and Stanley Klein Two gratings composed of lines were displayed one above the other, and

More information

Amblyopia ( lazy eye ) is a visual developmental disorder

Amblyopia ( lazy eye ) is a visual developmental disorder Reviews Unilateral Amblyopia Affects Two Eyes: Fellow Eye Deficits in Amblyopia Kimberly Meier 1 and Deborah Giaschi 2 1 Department of Psychology, University of British Columbia, Vancouver, British Columbia,

More information

Outline: Vergence Eye Movements: Classification I. Describe with 3 degrees of freedom- Horiz, Vert, torsion II. Quantifying units- deg, PD, MA III.

Outline: Vergence Eye Movements: Classification I. Describe with 3 degrees of freedom- Horiz, Vert, torsion II. Quantifying units- deg, PD, MA III. Outline: Vergence Eye Movements: Classification I. Describe with 3 degrees of freedom- Horiz, Vert, torsion II. Quantifying units- deg, PD, MA III. Measurement of Vergence:- Objective & Subjective phoria

More information

Suprathreshold spatial frequency detection and binocular interaction in strabismic and anisometropic amblyopia

Suprathreshold spatial frequency detection and binocular interaction in strabismic and anisometropic amblyopia Suprathreshold spatial frequency detection and binocular interaction in strabismic and anisometropic amblyopia Dennis M. Levi, Ronald S. Harwerth, and Ruth E. Manny We have investigated suprathreshold

More information

Microtropia Versus Bifoveal Fixation in Anisometropic Amblyopia

Microtropia Versus Bifoveal Fixation in Anisometropic Amblyopia ye (1991) 5, 576-584 Microtropia Versus Bifoveal Fixation in Anisometropic Amblyopia S. J. HARDMAN LA, M. P. SNAD, J. LOADS, M. P. RBINSTIN Nottingham Summary Microtropia with identity is a unique condition

More information

Southampton Eye Unit. Orthoptic Induction Pack

Southampton Eye Unit. Orthoptic Induction Pack Southampton Eye Unit Orthoptic Induction Pack 1 Orthoptics Orthoptics is an Allied Health Profession. It is a graduate profession with a 3 year degree course offered at Liverpool and Sheffield Universities,

More information

Binocular Luminance Summation in Humans With Defective Binocular Vision

Binocular Luminance Summation in Humans With Defective Binocular Vision Binocular Luminance Summation in Humans With Defective Binocular Vision Ruxandra Sirereanu Subjects with no functional binocularity (no stereopsis and no peripheral fusion) show much less binocular summation

More information

A mblyopia is the commonest childhood vision disorder

A mblyopia is the commonest childhood vision disorder 1552 EXTENDED REPORT Refractive adaptation in amblyopia: quantification of effect and implications for practice C E Stewart, M J Moseley, A R Fielder, D A Stephens, and the MOTAS cooperative... See end

More information

Patients and methods. There are 2 categories of patients with unilateral

Patients and methods. There are 2 categories of patients with unilateral British Journal of Ophthalmology, 1982, 66, 680-684 Results of treatment of anisohypermetropic amblyopia ithout strabismus DHAN KRISHNA SEN From the Department of Ophthalmology, Maulana Azad Medical College

More information

The Royal College of Ophthalmologists. Parent Information Squint/Strabismus

The Royal College of Ophthalmologists. Parent Information Squint/Strabismus Parent Information Squint/Strabismus This leaflet is designed to answer some of the general queries relating to squint in childhood. The Children s Eye Care Team An OPHTHALMOLOGIST is a doctor who specialises

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association Sensorimotor and Neurobehavioral Status Exams Page 1 of 5 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Sensorimotor and Neurobehavioral Status Exams for Optometric

More information

What do we perceive?

What do we perceive? THE VISUAL SYSTEM Aditi Majumder What do we perceive? Example: Switch off the light in room What we perceive Not only the property of the scene But also that of the visual system Our perception is filtered

More information

In most forms of strabismus, a patient s motor fusion mechanisms. Binocular Vision with Primary Microstrabismus

In most forms of strabismus, a patient s motor fusion mechanisms. Binocular Vision with Primary Microstrabismus Binocular Vision with Primary Microstrabismus Ronald S. Harwerth and Patricia M. Fredenburg PURPOSE. Patients with primary microstrabismus have a high degree of binocularity, which suggests that their

More information

Notes compiled for Pediatrics. Ophthalmology. (Med I, Block 5, OP)

Notes compiled for Pediatrics. Ophthalmology. (Med I, Block 5, OP) Notes compiled for Pediatrics Ophthalmology (Med I, Block 5, OP) Amblyopia and Strabismus University of Manitoba Faculty of Medicine MedII/OP7 Dr. P. Shuckett 2008-09 Objectives: 1. To state how to measure

More information

Neural circuits PSY 310 Greg Francis. Lecture 05. Rods and cones

Neural circuits PSY 310 Greg Francis. Lecture 05. Rods and cones Neural circuits PSY 310 Greg Francis Lecture 05 Why do you need bright light to read? Rods and cones Photoreceptors are not evenly distributed across the retina 1 Rods and cones Cones are most dense in

More information

Type of strabismus and changes to fusion measures

Type of strabismus and changes to fusion measures Type of strabismus and changes to fusion measures Carla Costa Lança, PhD Lisbon School of Health Technology carla.costa@estesl.ipl.pt There is no actual or potential conflict of interest in relation to

More information

Binocular Vision and Stereopsis Following Delayed Strabismus Surgery

Binocular Vision and Stereopsis Following Delayed Strabismus Surgery Binocular Vision and Stereopsis Following Delayed Strabismus Surgery Davood Gharabaghi, MD 1, Minoo Azadeh, MD 2 Abstract Purpose: Patients with infantile or childhood strabismus who do not achieve visual

More information

Lateral Geniculate Nucleus (LGN)

Lateral Geniculate Nucleus (LGN) Lateral Geniculate Nucleus (LGN) What happens beyond the retina? What happens in Lateral Geniculate Nucleus (LGN)- 90% flow Visual cortex Information Flow Superior colliculus 10% flow Slide 2 Information

More information

1. The responses of on-center and off-center retinal ganglion cells

1. The responses of on-center and off-center retinal ganglion cells 1. The responses of on-center and off-center retinal ganglion cells 2. Responses of an on-center ganglion cell to different light conditions 3. Responses of an on-center ganglion cells to different light

More information

The Effect of Successful Surgical Alignment on Improvement of Binocular Vision in Adults with Childhood Strabismus

The Effect of Successful Surgical Alignment on Improvement of Binocular Vision in Adults with Childhood Strabismus The Effect of Successful Surgical Alignment on Improvement of Binocular Vision in Adults with Childhood Strabismus Dima Andalib, MD 1 Reza Nabie, MD 1 Bayan Poormohammad, MD 2 Abstract Purpose: To evaluate

More information

Physiology of suppression in strabismic amblyopia

Physiology of suppression in strabismic amblyopia British Journal of Ophthalmology 1996; 80: 373-377 373 PERSPECTIVE Physiology of suppression in strabismic amblyopia Richard Harrad, Frank Sengpiel, Colin Blakemore It is 100 years since von Graefe first

More information

LISC-322 Neuroscience Cortical Organization

LISC-322 Neuroscience Cortical Organization LISC-322 Neuroscience Cortical Organization THE VISUAL SYSTEM Higher Visual Processing Martin Paré Assistant Professor Physiology & Psychology Most of the cortex that covers the cerebral hemispheres is

More information

10/4/2016. Organic (systemic) Form deprivation (structural) Strabismic Refractive Isometric Anisometric

10/4/2016. Organic (systemic) Form deprivation (structural) Strabismic Refractive Isometric Anisometric Marc B. Taub, OD, MS, FAAO, FCOVD Chief, Vision Therapy and Rehabilitation Southern College of Optometry Editor in Chief, Optometry & Visual Performance A difference in the VA of the two eyes of at least

More information

Visual Deficits in Amblyopia

Visual Deficits in Amblyopia Human Amblyopia Lazy Eye Relatively common developmental visual disorder (~2%) Reduced visual acuity in an otherwise healthy and properly corrected eye Associated with interruption of normal early visual

More information

Management of Diplopia Indiana Optometric Association Annual Convention April 2018 Kristine B. Hopkins, OD, MSPH, FAAO

Management of Diplopia Indiana Optometric Association Annual Convention April 2018 Kristine B. Hopkins, OD, MSPH, FAAO Management of Diplopia Indiana Optometric Association Annual Convention April 2018 Kristine B. Hopkins, OD, MSPH, FAAO For patients with diplopia, the clinician must differentiate monocular from binocular

More information

V1 (Chap 3, part II) Lecture 8. Jonathan Pillow Sensation & Perception (PSY 345 / NEU 325) Princeton University, Fall 2017

V1 (Chap 3, part II) Lecture 8. Jonathan Pillow Sensation & Perception (PSY 345 / NEU 325) Princeton University, Fall 2017 V1 (Chap 3, part II) Lecture 8 Jonathan Pillow Sensation & Perception (PSY 345 / NEU 325) Princeton University, Fall 2017 Topography: mapping of objects in space onto the visual cortex contralateral representation

More information

Reports. Accommodative and fusional components of fixation disparity. JOHN L. SEMMLOW AND GEORGE HUNG.

Reports. Accommodative and fusional components of fixation disparity. JOHN L. SEMMLOW AND GEORGE HUNG. Reports Accommodative and fusional components of fixation disparity. JOHN L. SEMMLOW AND GEORGE HUNG. Traditional measurements of fixation disparity, like other binocidar measurements, confound influences

More information

City, University of London Institutional Repository

City, University of London Institutional Repository City Research Online City, University of London Institutional Repository Citation: Conway, M. L., Thomas, J. and Subramanian, A. (2012). Is the Aligning Prism Measured with the Mallett Unit Correlated

More information

Differences in temporal frequency tuning between the two binocular mechanisms for seeing motion in depth

Differences in temporal frequency tuning between the two binocular mechanisms for seeing motion in depth 1574 J. Opt. Soc. Am. A/ Vol. 25, No. 7/ July 2008 Shioiri et al. Differences in temporal frequency tuning between the two binocular mechanisms for seeing motion in depth Satoshi Shioiri, 1, * Tomohiko

More information

Lighta part of the spectrum of Electromagnetic Energy. (the part that s visible to us!)

Lighta part of the spectrum of Electromagnetic Energy. (the part that s visible to us!) Introduction to Physiological Psychology Vision ksweeney@cogsci.ucsd.edu cogsci.ucsd.edu/~ /~ksweeney/psy260.html Lighta part of the spectrum of Electromagnetic Energy (the part that s visible to us!)

More information

Visual Selection and Attention

Visual Selection and Attention Visual Selection and Attention Retrieve Information Select what to observe No time to focus on every object Overt Selections Performed by eye movements Covert Selections Performed by visual attention 2

More information

The Time Course of Inreroculor Suppression in Normal and Amblyopic Subjects

The Time Course of Inreroculor Suppression in Normal and Amblyopic Subjects Investigative Ophthalmology & Visual Science. Vol. 32, No. 9, August 1991 Copyright Association for Research in Vision and Ophthalmology The Time Course of Inreroculor Suppression in Normal and Amblyopic

More information

Factors involved in the production of amblyopia

Factors involved in the production of amblyopia Brit. J. Ophthal. (I 974) 58, 158 Factors involved in the production of amblyopia G. K. VON NOORDEN From the Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, U.S.A. If amblyopia

More information

Cambridge CB2 3EG (Received 8 November 1972)

Cambridge CB2 3EG (Received 8 November 1972) J. Physiol. (1973), 232, pp. 149-162 149 With 8 text-figures Printed in Great Britain PSYCHOPHYSICAL EVIDENCE FOR SUSTAINED AND TRANSIENT DETECTORS IN HUMAN VISION BY J. J. KULIKOWSKI AND D. J. TOLHURST*

More information

Detecting disorder in spatial vision

Detecting disorder in spatial vision Vision Research 40 (2000) 2307 2327 www.elsevier.com/locate/visres Detecting disorder in spatial vision Dennis M. Levi a, *, Stanley A. Klein b, Vineeta Sharma a,1, Lisa Nguyen a a Uni ersity of Houston,

More information

Supplementary Online Content

Supplementary Online Content Supplementary Online Content Gao TY, Guo CX, Babu RJ, et al; the BRAVO Study Team. Effectiveness of a binocular video game vs placebo video game for improving visual functions in older children, teenagers,

More information

Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice

Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice Valerie M. Kattouf O.D. Chief, Pediatric/Binocular Vision Service FAAO, FCOVD Illinois College of Optometry Associate Professor

More information

"A" AND "V" PHENOMENA*t

A AND V PHENOMENA*t Brit. J. Ophthal. (1966) 50, 718 "A" AND "V" PHENOMENA*t DHANWANT SINGH, GURBUX SINGH, L. P. AGGARWAL, AND PREM CHANDRA BY From the Department of Ophthalmology, Government Medical College, Patiala, and

More information

Strabismus. Nathalie Azar, MD Pediatric Ophthalmology for the Non-Ophthalmologist April 7, 2018 TERMINOLOGY:

Strabismus. Nathalie Azar, MD Pediatric Ophthalmology for the Non-Ophthalmologist April 7, 2018 TERMINOLOGY: Strabismus Nathalie Azar, MD Pediatric Ophthalmology for the Non-Ophthalmologist April 7, 2018 TERMINOLOGY: Strabismus comes from the Greek word Strabismos which means to squint. For accuracy when describing

More information

It has been estimated that up to 10

It has been estimated that up to 10 It has been estimated that up to 10 per cent of primary care patients attend an eye examination complaining of some form of binocular vision anomaly. With the ever-increasing use of computers in the workplace

More information

SENSES: VISION. Chapter 5: Sensation AP Psychology Fall 2014

SENSES: VISION. Chapter 5: Sensation AP Psychology Fall 2014 SENSES: VISION Chapter 5: Sensation AP Psychology Fall 2014 Sensation versus Perception Top-Down Processing (Perception) Cerebral cortex/ Association Areas Expectations Experiences Memories Schemas Anticipation

More information

Adaptation of the Vestibulo-Ocular Reflex in Amblyopia

Adaptation of the Vestibulo-Ocular Reflex in Amblyopia Adaptation of the Vestibulo-Ocular Reflex in Amblyopia Carol A. Wesfall and Clifton M. Schor Adaptation of the vestibulo-ocular reflex (VOR) is demonstrated by changes in gain in response to discrepancies

More information

Amblyopia Definition 9/25/2017. Strabismic Amblyopia. Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice

Amblyopia Definition 9/25/2017. Strabismic Amblyopia. Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice Amblyopia 101: How to use Current Amblyopia Research in Clinical Practice Valerie M. Kattouf O.D. Chief, Pediatric/Binocular Vision Service FAAO, FCOVD Illinois College of Optometry Associate Professor

More information

Article 4 Effect of Test Target Size on Phoria and Horizontal Fusional Vergence

Article 4 Effect of Test Target Size on Phoria and Horizontal Fusional Vergence Article 4 Effect of Test Target Size on Phoria and Horizontal Fusional Vergence Ayishetu Oshoke Shuaibu, OD, Department of Optometry, University of Benin, Edo State, Nigeria Oseleonomhen Monica Odigie,

More information

NIH Public Access Author Manuscript J AAPOS. Author manuscript; available in PMC 2006 April 25.

NIH Public Access Author Manuscript J AAPOS. Author manuscript; available in PMC 2006 April 25. NIH Public Access Author Manuscript Published in final edited form as: J AAPOS. 2005 December ; 9(6): 542 545. The Effect of Amblyopia Therapy on Ocular Alignment Michael X. Repka, MD a, Jonathan M. Holmes,

More information

THE SYMPTOM of diplopia can

THE SYMPTOM of diplopia can Recently Acquired Diplopia in Adults With Long-standing Strabismus Burton J. Kushner, MD CLINICAL SCIENCES Background: The evaluation and management of recentonset diplopia in an adult with a history of

More information

Incidence of Amblyopia in Strabismic Population

Incidence of Amblyopia in Strabismic Population Original Article Incidence of Amblyopia in Strabismic Population Mian M. Shafique, NaeemUllah, Nadeem H. Butt, Muhammad Khalil, Tayyaba Gul Pak J Ophthalmol 2007, Vol. 23 No. 1.................................................................................................

More information

REFERENCES. Amblyopic abnormality involves neural mechanisms concerned with movement processing. INGO RENTSCHLER, RUDOLF

REFERENCES. Amblyopic abnormality involves neural mechanisms concerned with movement processing. INGO RENTSCHLER, RUDOLF Volume 20 Number 5 Reports 695 terrupt the light quite as abruptly as a mechanical shutter. There is reason to believe, however, that the differences in waveform, particularly in the first section of the

More information

Intermittent Exotropia, When to Recommend Glasses and When to Perform Surgery?

Intermittent Exotropia, When to Recommend Glasses and When to Perform Surgery? Med. J. Cairo Univ., Vol. 86, No. 1, March: 289-296, 2018 www.medicaljournalofcairouniversity.net Intermittent Exotropia, When to Recommend Glasses and When to Perform Surgery? SHAIMAA H.M. SOKEER, M.Sc.;

More information

Maldevelopment of Visual Motion Processing in Humans Who Had Strabismus with Onset in Infancy

Maldevelopment of Visual Motion Processing in Humans Who Had Strabismus with Onset in Infancy The Journal of Neuroscience September 1986, 6(9): 2495258 Maldevelopment of Visual Motion Processing in Humans Who Had Strabismus with Onset in Infancy Lawrence Tychsen*,-f and Stephen G. Lisberger* *Division

More information

THE SEVEN PRIMARY POSITIONS OF GAZE*t

THE SEVEN PRIMARY POSITIONS OF GAZE*t Brit. J. Ophthal. (1967) 51, 105 THE SEVEN PRIMARY POSITIONS OF GAZE*t BY Brooklyn, New York THE existence of multiple primary positions of gaze and the need for investigating the changing binocular status

More information

TUMBLING E RESOLUTION PERIMETRY IN GLAUCOMA

TUMBLING E RESOLUTION PERIMETRY IN GLAUCOMA Tumbling E resolution perimetry in glaucoma 179 TUMBLING E RESOLUTION PERIMETRY IN GLAUCOMA FERGAL A. ENNIS 1, ROGER S. ANDERSON 1, WINSTON S. McCLEAN 1 and SIMON J.A. RANKIN 2 1 Vision Science Research

More information

American Association of Certified Orthoptists AAPOS Workshop 2013:

American Association of Certified Orthoptists AAPOS Workshop 2013: American Association of Certified Orthoptists AAPOS Workshop 2013: DVD - A Conceptual, Clinical and Surgical Overview Friday April 5, 2013 Boston, Massachusetts 1 Moderators: Edward L Raab, MD, JD Alex

More information

Specific deficits of flicker sensitivity in glaucoma and ocular hypertension

Specific deficits of flicker sensitivity in glaucoma and ocular hypertension Specific deficits of flicker sensitivity in glaucoma and ocular hypertension Christopher W. Tyler Temporal modulation sensitivity for a 5 flickering field was measured in central and peripheral retina

More information

INTRODUCTION TO BINOCULAR VISION TESTING: LECTURE 1

INTRODUCTION TO BINOCULAR VISION TESTING: LECTURE 1 INTRODUCTION TO BINOCULAR VISION TESTING: LECTURE 1 Dr Hilary Gaiser OD, MSc Assistant Professor of Optometry New England College of Optometry This presentation has been created for Orbis International

More information

Open Access Journal of Ophthalmology

Open Access Journal of Ophthalmology Esotropia Anurag Narula 1 * and Shilpa Singh 2 1Safdarjung Hospital, VMMC, India 2Visitech Eye Centre, India *Corresponding author: Anurag Narula, Consultant, Safdarjung Hospital, Vardhman Short Communication

More information

Vision Science III Handout 15

Vision Science III Handout 15 Vision Science III Handout 15 NYSTAGMUS Nystagmus describes a pattern of eye movements in which the eyes move to and fro, usually with alternating Slow and Fast phases. Nystagmus occurs normally in some

More information

Anomalous Retinal Correspondence: Neuroanatomic Mechanism in Strabismic Monkeys and Clinical Findings in Strabismic Children

Anomalous Retinal Correspondence: Neuroanatomic Mechanism in Strabismic Monkeys and Clinical Findings in Strabismic Children Anomalous Retinal Correspondence: Neuroanatomic Mechanism in Strabismic Monkeys and Clinical Findings in Strabismic Children Agnes M. F. Wong, MD, a Gregg T. Lueder, MD, a Andreas Burkhalter, PhD, b and

More information

Ocular Motility in Health and Disease

Ocular Motility in Health and Disease Ocular Motility in Health and Disease Contents: Extraocular Muscles Eye Movements Single Binocular Vision Strabismus Amblyopia Objectives: By the end of this course the undergraduate student should be

More information

This 3-year-old presented with an alternating esotropia of two-month duration. Her initial

This 3-year-old presented with an alternating esotropia of two-month duration. Her initial Management of Significant Refractive Error Abstract: This case report is of a child who was referred to me by a practicing optometrist. This 3-year-old presented with an alternating esotropia of two-month

More information

Visual Physiology. Perception and Attention. Graham Hole. Problems confronting the visual system: Solutions: The primary visual pathways: The eye:

Visual Physiology. Perception and Attention. Graham Hole. Problems confronting the visual system: Solutions: The primary visual pathways: The eye: Problems confronting the visual system: Visual Physiology image contains a huge amount of information which must be processed quickly. image is dim, blurry and distorted. Light levels vary enormously.

More information

Strabismus: Esotropia and Exotropia

Strabismus: Esotropia and Exotropia OPTOMETRIC CLINICAL PRACTICE GUIDELINE Vision Service Plan is proud to underwrite this landmark series of Clinical Practice Guidelines. These Guidelines will be a significant patient care information resource

More information

Howell Modified Test for qualitative and quantitative assessment of near phoria

Howell Modified Test for qualitative and quantitative assessment of near phoria Howell Test for qualitative and quantitative assessment of near phoria A.V. Kriuchko, ophthalmologist Optic Rehabilitation Center OKTAR; Poltava (Ukraine) E-mail: lkkz@ukr.net Key-words: binocular vision,

More information

Screening in a School for Visual Acuity and Amblyopia

Screening in a School for Visual Acuity and Amblyopia Original Article Screening in a School for Visual Acuity and Amblyopia Ejaz Ahmad Javed, Muhammad Sultan ABSTRACT Objective: To detect the visual acuity by Snellen visual acuity chart and then to find

More information

The lowest level of stimulation that a person can detect. absolute threshold. Adapting one's current understandings to incorporate new information.

The lowest level of stimulation that a person can detect. absolute threshold. Adapting one's current understandings to incorporate new information. absolute threshold The lowest level of stimulation that a person can detect accommodation Adapting one's current understandings to incorporate new information. acuity Sharp perception or vision audition

More information

J. Physiol. (I957) I37,

J. Physiol. (I957) I37, 488 J. Physiol. (I957) I37, 488-508 THE RECIPROCAL ACTIONS OF ACCOMMODATION AND CONVERGENCE BY E. F. FINCHAM AND J. WALTON From the Institute of Ophthalmology, Judd Street, London, W.C. 1 and the Northampton

More information

HYPOTHESIS INTRODUCTION. Trans Am Ophthalmol Soc 2006;104:

HYPOTHESIS INTRODUCTION. Trans Am Ophthalmol Soc 2006;104: THE INFLUENCE OF REFRACTIVE ERROR MANAGEMENT ON THE NATURAL HISTORY AND TREATMENT OUTCOME OF ACCOMMODATIVE ESOTROPIA (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS) BY BRADLEY CHARLES BLACK MD ABSTRACT Purpose:

More information

Depth aliasing by the transient-stereopsis system

Depth aliasing by the transient-stereopsis system Vision Research 39 (1999) 4333 4340 www.elsevier.com/locate/visres Depth aliasing by the transient-stereopsis system Mark Edwards *, Clifton M. Schor School of Optometry, Uni ersity of California, Berkeley,

More information

Article. Reverse-Engineering of Hyperopic Anisometropic Refractive Amblyopia. Leonard J. Press, OD, FAAO, FCOVD; Daniel J.

Article. Reverse-Engineering of Hyperopic Anisometropic Refractive Amblyopia. Leonard J. Press, OD, FAAO, FCOVD; Daniel J. Article Reverse-Engineering of Hyperopic Anisometropic Refractive Amblyopia Leonard J. Press, OD, FAAO, FCOVD; Daniel J. Press, OD, FCOVD Private Practice, Fair Lawn, NJ Abstract Background. Uncompensated

More information

Double Vision as a Presenting Symptom in Adults Without Acquired or Long- Standing Strabismus

Double Vision as a Presenting Symptom in Adults Without Acquired or Long- Standing Strabismus Double Vision as a Presenting Symptom in Adults Without Acquired or Long- Standing Strabismus Sara Shippman, C.O. Larisa Heiser, C.O. Kenneth R. Cohen, M.D., F.A.C.S. Lisabeth Hall, M.D. ABSTRACT Background:

More information

Carlson (7e) PowerPoint Lecture Outline Chapter 6: Vision

Carlson (7e) PowerPoint Lecture Outline Chapter 6: Vision Carlson (7e) PowerPoint Lecture Outline Chapter 6: Vision This multimedia product and its contents are protected under copyright law. The following are prohibited by law: any public performance or display,

More information

CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System

CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System Lecturer: Jitendra Malik Scribe: Ryan White (Slide: layout of the brain) Facts about the brain:

More information

Improvement in Vernier Acuity in Adults With Amblyopia

Improvement in Vernier Acuity in Adults With Amblyopia Improvement in Vernier Acuity in Adults With Amblyopia Practice Makes Better Dennis M. Levi* Uri Polat,^ and Ying-Sheng Hu* Purpose. To determine the nature and limits of visual improvement through repetitive

More information

Lateral interactions in visual perception of temporal signals: cortical and subcortical components

Lateral interactions in visual perception of temporal signals: cortical and subcortical components PSYCHOLOGY NEUROSCIENCE Psychology & Neuroscience, 2011, 4, 1, 57-65 DOI: 10.3922/j.psns.2011.1.007 Lateral interactions in visual perception of temporal signals: cortical and subcortical components Claudio

More information

ANDERSON-KESTENBAUM OPERATION FOR

ANDERSON-KESTENBAUM OPERATION FOR Brit. J. Ophthal. (1963) 47, 339. ANDERSON-KESTENBAUM OPERATION FOR ASYMMETRICAL GAZE NYSTAGMUJS* BY A. STERNBERG-RAAB 2nd Eye Hospital, Budapest Medical School, Hungary (Head of Department, Prof. Tibor

More information

Supplementary Note Psychophysics:

Supplementary Note Psychophysics: Supplementary Note More detailed description of MM s subjective experiences can be found on Mike May s Perceptions Home Page, http://www.senderogroup.com/perception.htm Psychophysics: The spatial CSF was

More information

Preoperative Factors Influencing Effectiveness of Surgery in Adult Strabismus

Preoperative Factors Influencing Effectiveness of Surgery in Adult Strabismus ELSEVIER Preoperative Factors Influencing Effectiveness of Surgery in Adult Strabismus Fumiko Umazume, Hiroshi Ohtsuki and Satoshi Hasebe Department of Ophthalmology, Okayama University Medical School,

More information

Extraocular Muscles and Ocular Motor Control of Eye Movements

Extraocular Muscles and Ocular Motor Control of Eye Movements Extraocular Muscles and Ocular Motor Control of Eye Movements Linda K. McLoon PhD mcloo001@umn.edu Department of Ophthalmology and Visual Neurosciences Your Eyes Are Constantly Moving. Yarbus, 1967 Eye

More information

LEA Color Vision Testing

LEA Color Vision Testing To The Tester Quantitative measurement of color vision is an important diagnostic test used to define the degree of hereditary color vision defects found in screening with pseudoisochromatic tests and

More information

Richman Face Dot Test Paddle

Richman Face Dot Test Paddle Introduction and Purpose Richman Face Dot Test Paddle Developed by Jack Richman, OD, FAAO, FCOVD Professor, Pediatric Optometry/ Binocular Vision Services New England Eye Institute New England College

More information

Senses are transducers. Change one form of energy into another Light, sound, pressure, etc. into What?

Senses are transducers. Change one form of energy into another Light, sound, pressure, etc. into What? 1 Vision 2 TRANSDUCTION Senses are transducers Change one form of energy into another Light, sound, pressure, etc. into What? Action potentials! Sensory codes Frequency code encodes information about intensity

More information

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology. Visual Suppression in Intermittent Exotropia during Binocular Alignment

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology. Visual Suppression in Intermittent Exotropia during Binocular Alignment Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology Visual Suppression in Intermittent Exotropia during Binocular Alignment Ignacio Serrano-Pedraza, Vina Manjunath, Olaoluwakitan Osunkunle, Michael

More information

Convergence accommodation to convergence (CA/C) ratio: stability with different levels of convergence demand

Convergence accommodation to convergence (CA/C) ratio: stability with different levels of convergence demand : 60 64 Convergence accommodation to convergence (CA/C) ratio: stability with different levels of convergence demand KOMAL J. HIRANI BMedSci (Hons) AND ALISON Y. FIRTH MSc DBO(T) Academic Unit of Ophthalmology

More information

Introduction to Physiological Psychology

Introduction to Physiological Psychology Introduction to Physiological Psychology Vision ksweeney@cogsci.ucsd.edu cogsci.ucsd.edu/~ksweeney/psy260.html This class n Sensation vs. Perception n How light is translated into what we see n Structure

More information

7. Sharp perception or vision 8. The process of transferring genetic material from one cell to another by a plasmid or bacteriophage

7. Sharp perception or vision 8. The process of transferring genetic material from one cell to another by a plasmid or bacteriophage 1. A particular shade of a given color 2. How many wave peaks pass a certain point per given time 3. Process in which the sense organs' receptor cells are stimulated and relay initial information to higher

More information

Temporal Feature of S-cone Pathway Described by Impulse Response Function

Temporal Feature of S-cone Pathway Described by Impulse Response Function VISION Vol. 20, No. 2, 67 71, 2008 Temporal Feature of S-cone Pathway Described by Impulse Response Function Keizo SHINOMORI Department of Information Systems Engineering, Kochi University of Technology

More information

Amblyopia: is visual loss permanent?

Amblyopia: is visual loss permanent? 952 Ophthalmology and Vision Science, Queen s University, Royal Victoria Hospital, Belfast BT 12 6BA M K El Mallah U Chakravarthy P M Hart Corrrespondence to: Usha Chakravarthy u.chakravarthy@qub.ac.uk

More information