ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE
|
|
- Ruth Ryan
- 6 years ago
- Views:
Transcription
1 AFFICHEURS DÉPORTÉS - REMOTE INTERFACES ATyS D10 & D20 Notice d utilisation - Operating instructions F GB MAKE YOUR BUSINESS SAFE SOCOMEC GROUP SWITCHING PROTECTION & UPS
2 F Sommaire PRÉSENTATION GÉNÉRALE ATyS D10 et D20 3 INSTALLATION ATyS D10 et D20 4 Montage 4 Raccordements 4 Caractéristiques 4 UTILISATION ATyS D10 5 Affichage 5 UTILISATION ATyS D20 6 Affichage 6 Clavier 7 Version logiciel 7 Programmation 8 Exploitation 18 Fonctionnement 20 Visualisation 20 GB Summary GENERAL PRESENTATION ATyS D10 & D20 23 INSTALLATION ATyS D10 & D20 24 Mounting 24 Connection 24 Characteristics 24 ATYS D10 25 Display 25 ATyS D20 26 Display 26 Keypad 27 Software version Control and Test modes 38 Operational sequences 40 Visualisation 40 2
3 GENERAL PRESENTATION ATyS D10 & D20 ATyS D10 and D20 models are remote interfaces designed for easy integration on front panels. They can be connected to ATyS 6e, 6m and C30 products to allow remote access to display or control features. 23
4 INSTALLATION ATyS D10 & D20 Mounting Door fixing: 2 holes, diameter 22.5 mm Maximum thickness of the door: 20 mm 96 x 96 Ø ATYS 161 A = = ATYS 147 A 1 Door drilling (1) RJ45 plug for ATyS connection Connection Connection only on AtyS 6e, 6m or C30 products. > Cable RJ45 type 8/8 not isolated Type RJ45 ATyS C30 > Maximum cable length 3m > Tightning torque 4 N.m ATYS 313 A GB ATyS D10/D20 Characteristics > IP IP21 standard IP54 using gasket > Operation Temperature: -10 to + 55 C hygrometry: 80% humidity at 55 C 95% humidity at 40 C 24
5 ATyS D10 Display ATyS D10 allows remote display of transfer system positions, sources availability and operational mode. and operations remain available directly on master product (ATyS 6e, 6m or C30). Source 1 available Power On ATyS Product faulty, transfer error Possible to reset after error disappearance the power supplies of the master product (ATyS 6e, 6m, C30) for 3 minutes Source 2 available Transfer system in position 1 ATYS 145 B Transfer system in Automatic mode Transfer system in position 0 Transfer system in position 2 25
6 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation Display ATyS D20 allows remote display of transfer system positions, sources availability, operational mode and metering. and operations (Test and Control) are also available. Master product (ATyS 6e, 6m or C30) display is deactivated as soon as the remote interface is connected. Power On Manual mode active Padlock* Product faulty, transfer error Possible to reset after error disappearance: switch off the power supplies of the master product (ATyS 6e, 6m, C30) for 3 minutes Source 1 available Source 2 available Transfer system in position 1 Transfer system in position 2 Transfer system in position 0 Transfer system in automatic mode ATYS 146 B Control mode active Test mode active mode active * only on ATyS 6e and 6m 26
7 Display Priority source Phases (wires) displayed Units Informations source 1 source 2 sources 1 & 2 (split screen) Power factor Capacitive or inductive Signed values (power) Values Keypad ATYS 146 C ATYS 318 A Access to AUT, Test, Control and Prog modes Direct Access to Test and Control functionalities or navigation Allows main menu access in visualisation mode or validation Software version Software version of the master product is displayed immediately after ATyS 6e, 6m or C30 power on. ATYS 319 A 27
8 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation > Enter into programming mode Step 1: Press the mode push button until Prog led is blinking Step 2: Press validation push button. PROG led becomes fixed and access code is displayed Step 3: Enter access code (1000 factory default) using keypad left, right, top and bottom Step 4: Press validation push button to enter programming mode > mode exit Step 1: Press the ESC push button when not entering any value, to come back to main programming menu Step 2: Press again on ESC push button to exit programming New Active mode (Automatic or Manual) depends on information from the master device (ATyS 6e, 6m ou C30) 28
9 > Navigation in programming mode Step 1: To access required menu, press navigation push buttons left and right Step 2: To access parameter to modify press navigation push buttons top and bottom Step 3: To modify the parameter, press push button right to make the required parameter blinking Step 4: Press push buttons top and bottom to increment or decrement the value of the parameter Step 5: Press validation push button to validate In case of parameter displayed on 2 lines, press validation push button after first line modification to access next one ESC push button allows to come back to main menu or to cancel the modification 29
10 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation ARCHITECTURE OF THE PROGRAMMING MENU ATYS 327 A * 30
11 * * * * only on Atys 6m option on ATyS 6e & 6m * only on ATyS C30 visible if option LS selected and active 31
12 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation VARIABLES CHARACTERISTICS > Setup LCD Denomination Setting range Default values nt Type of network 1BL, 2BL, 2NBL 4NBL (cf. ATyS 6 or C30 instruction manual) 3NBL, 4NBL, 41NBL, 42NBL Un Network Nominal voltage 100 to 480 V 400 V Phase-Neutral voltage for 1BL & 41NBL Phase-Phase voltage for others ScE Source 1 - Switch I or II configuration I, II I Source 1 (controlled and displayed) linked to switch I or II (depending on cabling) Fn Network nominal Frequency 50 or 60 Hz 50 Hz Ct* CTs primary current 50 to 5000/5 A 500/5 A (5 A secondary CT) Gen Genset start signal state NO, NC NO Normally opened or closed Pri Network priority selection 1, 2 1 Keypad selection (1 or 2) Also possible via external contact Using option Mtf Manual Retransfer Yes, No No Activation of the feature LoG Type of control logic selection IMP, CON, bre* IMP Impulse, contactor or breaker* AC* Number of position auxiliary contacts used, depending on transfer 0, 2, 3 2 device type (switch, contactor, breaker) rn1 Allows 0 position command after loss of main source (source 1) Yes, No No rn2 Allows 0 position command after loss of emergency source (source 2) Yes, No No CrS Number of permutation counter Reset Yes, No No CP code modification 0001 to Possible to change the code * only on AtyS 6m only on ATyS 6e & 6m * only on ATyS C30. 32
13 > Voltage thresholds LCD Denomination Setting range Default values ou Network 1 over voltage threshold % 115% ouh Network 1 over voltage threshold hysteresis % 110% (< ou) uu Network 1 under voltage threshold 80-98% 85% uuh Network 1 under voltage threshold hysteresis 81-99% 95% (> uu) ou Network 2 over voltage threshold % 115% ouh Network 2 over voltage threshold hysteresis % 110% (< ou) uu Network 2 under voltage threshold 80-98% 85% uuh Network 2 under voltage threshold hysteresis 81-99% 95% (> uo) Values defined are % of nominal values. Hysteresis thresholds must be programmed according to over and under voltage thresholds (respectively under & above). > Frequency thresholds LCD Denomination Setting range Default values of Network 1 over frequency threshold 101 to 120% 105% ofh Network 1 over frequency threshold hysteresis % 103% (< of) uf Network 1 under frequency threshold 80-99% 95% ufh Network 1 under frequency threshold hysteresis % 97% (> uf) of Network 2 over frequency threshold % 105% ofh Network 2 over frequency threshold hysteresis % 103% (< of) uf Network 2 under frequency threshold 80-99% 95% ufh Network 2 under frequency threshold hysteresis % 97% (> uf) Values defined are % of nominal values. Hysteresis thresholds must be programmed according to over and under frequency thresholds (respectively under & above). 33
14 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation > Timers LCD Denomination Setting range Default values Mft Main Failure Timer From 0 to 60 s 5 s Delays priority network failure detection dtt Delay on transfer timer From 0 to 60 s 5 s Emergency network stability validation before transfer OMf O Main Failure Timer From 0 to 20 s 0 s Rest in O position when transferring from main network to emergency network Mrt Main Return Timer From 0 to 30 min 1 min Main network stability validation before re-transfer OMr O Main Return Timer From 0 to 20 s 5 s Rest in O position when re-transferring from emergency network to main network Cdt Cool Down Timer From 0 to 10 min 4 min Allows generator cooling down period after load s retransfer from emergency source (generator) to Main source > Communication Only on ATyS 6e or 6m in case of optional communication module. LCD Denomination Setting range Default values Add Device address 1 to bd Communication speed 2400, 4800, 9600, , StoP Stop bit 1, 2 1 PAr Parity bit No, Odd, Even No 34
15 > Inputs/Outputs 2 inputs (In1, In2) and 2 outputs (Ou1, Ou2) as standard on ATyS C30. Possibility to connect 2 modules 2 Inputs/2 Outputs on ATyS 6e & 6m. - First module: In1, In2, Ou1, Ou2 - Second module In3, In4, Ou3, Ou4. Refer to ATyS C30, 6e or 6m instruction manual for terminals identification. Input/ Output Function Relay State I1 to I4 Ft1, Ft2, Ft3, Ft4, Pri, NO or NC Mtf, S2A, Man, TOL, TFL, EJP, CTS O1 to O4 S1A, S2A, LS, / NO Input (In2, Ft2) and output (Ou1, S1A) programming example: Step 1: Press right push button to make first variable blinking (Ft2 ou S1A) Step 2: press top and bottom push buttons to modify the variable Step 3: press validation Step 4: press bottom push button to acces no variable selection ATYS 328 A 35
16 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation Variables description Inputs Variable Ft1 Ft2 Ft3* Ft4* Pri Mtf S2A Man CTS TOL TFL Description Fault input 1. The fault led is blinking as soon as the input is active and Ft1 is displayed on LCD. Reset when the input is de-activated Fault input 2. The fault led is blinking as soon as the input is active and Ft2 is displayed on LCD. Reset when the input is de-activated Fault input 3. The fault led is blinking as soon as the input is active and Ft3 is displayed on LCD. The transfer switch is immediately driven in 0 position. Keypad action (Esc) necessary to Reset the fault Fault input 4. The fault led is blinking as soon as the input is active and Ft4 is displayed on LCD. The transfer switch is immediately driven in 0 position. Keypad action (Esc) necessary to Reset the fault Priority network selection. Network 1 has priority when input is not activated. Network 2 has priority if input is active Remote manuel re-transfer. Feature identical to manual re transfert on keypad. Re-transfer from priority network to backup network is allowed from input activation (1 s front). The Mtf variable in the setup menu must be selected (Yes) to allow input recognition Information source 2 available (Genset) used instead of voltage/frequency measurement from ATyS (inhibited when S2A is selected) Information transfer system in manual mode. All automatic commands (+ test on load and control commands) are inhibited as soon as the input is activated Remote transfer control. Possible to initiate transfer from priority source to backup source before DTT ends. If DTT is set to its maximum value (60s), the transfer is initiated as soon as the input is activated (1 s front) Remote test on load. Started from input activation. Re-transfer is blocked until input de-activation Remote test off load. Started from input activation (remote genset start/stop) EJP 2 inputs one automatically affected to EJP input 1 for EJP advice, to start generator input 2 to transfer on emergency source Retransfer is activated when input 2 disapears * only on ATyS C30, specific fault operation (Ft2 and Ft3) only as option on ATyS C30, standard features on ATyS 6e et 6m. Outputs Variable S1A S2A LS Description Source 1 available. Output activated as soon as source 1 is considered available (similar to front led source 1) Source 2 available. Output activated as soon as source 2 is considered available (similar to front led source 2) Load shedding relay. LS timer corresponds to time available to disconnect the shed loads. The relay is activated before permutation on standby network according to LS timer. The relay is de-activated after retransfer on mains network and LS timer countdown 36
17 LOAD SHEDDING CONFIGURATION LS variable allows associated LS timer configuration. Output Associated funciton Setting range Default value O1 to O4 LS 0 to 60 s ( DTT)* 2 * In case of DTT variable configuration below LS, LS will be automatically set to to DTT value. > Example: load shedding configuration Step 1: Press right push button to make first variable blinking (LS) function Step 2: press push buttons top and bottom to modify the variable Step 3: Press validation Step 4: Press bottom push button to access timer value configuration ATYS 329 A GB timer 37
18 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation Control and Test modes It is possible to start test sequences or to control electrically the changeover system from keypad. NAVIGATION > Enter Control or Test modes Step 1: Press mode push button to make test or control led blinking Step 2: Press validation push button to make control or test led become fixed CONTROL MODE Access code is displayed directly TEST MODE It is possible to test leds and LCD without entering any code by pressing directly Test on load or test off load access codes are displayed after pressing or Enter the code 4000 using left, right, top and bottom push buttons Press validation push button to enter 38
19 Control and Test modes > Exit control or test modes Press ESC push button The new operational mode (automatic or manual) depends on information from master ATyS (6e, 6m ou C30) > Control or Test modes use Direct access by pressing and To start a test (off load or on load) or to control the changeover switch electrically, press, and push buttons 39
20 ATyS D20 Display Keypad Software version Control and Test modes Operational sequences Visualisation Operational sequences Refer to ATyS 6e, 6m or C30 manuals for more information on operational sequences and controls: sources control, tests cycles, loss of priority source sequence, priority source return sequence. Visualisation It is possible to display controlled parameters in both automatic and manual modes (but not during programming). No code is required to perform visualisation. Permutation cycles have priority over visualisation and display timer countdown during cycle operation. > If both sources are available: One visualisation screen is split into 2 parts and displays simultaneously voltage and frequency values on both networks. If a timer is active, on one of the source, its countdown is displayed instead of voltage and frequency values. Examples: Without keypad activation or any operational sequence during 5 minutes, the LCD comes back to default display mode and stops the backlight. > If only one source is present: During permutation cycle, voltage and frequency values of the available source (active) are displayed on 2 lines. The name of the active timer and its countdown are displayed on remaining 2 lines. Out of a permutation cycle, phase to phase voltages and frequency are displayed. Examples: ATYS 331 A ATYS 332 A Press left, right, top & bottom push buttons to access available screens Press navigation push button to navigate in visualisation, displaying all available screens 40
21 Visualisation ARCHITECTURE OF VISUALISATION MENU * * * * * * ATYS 333 A * only on AtyS 6e & 6m only U3-1 on AtyS C30 * only on ATyS 6m visible if option LS selected and active 41
22
23
24 SOCOMEC - Ref.: A - 02/05 HEAD OFFICE SOCOMEC GROUP SWITCHGEAR AND UPS S.A. capital R.C. Strasbourg B 1, rue de Westhouse - B.P Benfeld Cedex Tél Fax SALES MANAGEMENT DIVISION SOCOMEC 95, rue Pierre Grange Fontenay-sous-Bois Cedex Tél Fax This document is not contractual. SOCOMEC reserves the right to modify features without prior notice in view of continued improvements.
ATyS Bypass Enclosed solution from 40 to 3200 A
ATyS Bypass Enclosed solution from 40 to 3200 A A complete enclosed range of ATyS dedicated to bypass function Architecture SINGLE LINE DOUBLE LINE Voltage Sensing Voltage Sensing RANGE FROM 40 TO 3200
More informationATyS d H Remotely Operated Transfer Switching Equipment
Instruction Manual ATyS d H Remotely Operated Transfer Switching Equipment www.socomec.com/ en/atys-dh Contents. GERAL SAFETY INSTRUCTIONS... 4. INTRODUCTION.... 5 3. THE ATyS FAMILY PRODUCT RANGE... 6
More informationATyS Motorised and automatic changeover switches from 125 to 3200 A
ATyS Motorised and automatic changeover switches from 125 to 3200 A A totally safe transfer, whatever the application The design of the products in the ATyS family, based on proven load break switch technology,
More informationATyS S Remote Transfer Switching Equipment for Auto Mains Failure and Auto Transfer Switching applications up to 125 A
ATyS S Remote Transfer Switching Equipment for Auto Mains Failure and Auto Transfer Switching applications up to 125 A SOCOMEC: an independent manufacturer attentive to your needs The benefit of a specialist:
More informationArmstrong IVS 102 Drive Specification
Armstrong IVS 102 Drive Specification Part I: General Description 1. This specification covers complete variable frequency drives (VFDs) designated on the drawing schedules to be variable speed. All standard
More informationMini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port
AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides
More informationRDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE
RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE USER MANUAL Franklin Control Systems 11/11/2013 Table of Contents 1. Safety precautions... 1 2. Legends & Introduction... 2 3. Installation and wiring... 3 4. Setup...
More information2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage
«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to
More informationInstallation Instructions
Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing
More informationINSTRUCTION MANUAL. Arc Protection Unit
INSTRUCTION MANUAL AQ 110 Arc Protection Unit Instruction manual AQ 110 arc protection unit 2 (80) Revision 1.2 Date July 2011 Changes - Sensor chapter revised. (Fiber pictures and point sensor connections).
More informationDosimeter Setting Device
Instruction Manual Dosimeter Setting Device For Electronic Personal Dosimeter Dose-i (Unit:Sv, Version:1.05 English) WTA529748 a 1 / 38 Foreword Thank you for purchasing the Dosimeter Setting Device; a
More informationGraphical User Interface for Windows for MCM Module
Page 1 of 8 Installation:- Please ensure that you have the latest updated GUI and download the GUIv.x.x.x.x.ZIP from our website. Extract the folder to a temporary location (These files can be deleted
More informationTrane TR150 Variable Frequency Drive Guide Specification Section GENERAL II. PRODUCTS
Trane TR150 Variable Frequency Drive Guide Specification Section 15172 I. GENERAL A. This specification covers all variable frequency drives (VFDs) designated on the drawing schedules. All standard and
More informationSPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input
US Drives Inc. 2221 Niagara Falls Boulevard P.O. Box 281 Niagara Falls, NY 14304-0281 Tel: (716) 731-1606 Fax: (716) 731-1524 Visit us at www.usdrivesinc.com GUIDE Phoenix EX AC Drive Closed Loop AC Vector
More informationEpilepsy Sensor Transmitter
Epilepsy Sensor Transmitter Installation Guide t: 01977 661234 f: 01977 660562 e: enquiries@tunstall.com w: uk.tunstall.com Version: V0.1 (421V0R1.18) Contents 1. Features and Introduction... 3 Your Epilepsy
More informationVLT HVAC Drive. Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification. Section 15172
VLT HVAC Drive Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification I. PART 1- GENERAL A. DESCRIPTION Section 15172 1. This specification covers complete a variable frequency
More informationFor Electric Personal Dosimete Dose-i
Instruction Manual Dosime eter Setting Device For Electric Personal Dosimete er Dose-i (Unit:rem, Version:1.05 English) Issued on March 2015 WTA529893 1 / 38 Foreword Thank you for purchasing the Dosimeter
More informationprotection system 2014
POWER protection system 2014 GEWISS GROUP GEWISS is an international leader in the production of systems and components for low voltage electrical installations. The fact that development is seen as a
More informationEvolve 3 & 5 Service Manual
Evolve 3 & 5 Service Manual 1 Product Browse 2 Contents CHAPTER 1: SERIAL NUMBER LOCATION... 5 CHAPTER 2: CONSOLE INSTRUCTIONS 2.1 Console Overview... 6 2.1.1 Evolve 3 Console Overview... 6 2.1.2 Evolve
More informationASCO Power Control Systems Overview
ASCO Power Control Systems Overview POWER CONTROL CHALLENGES Today more than ever, continuous electrical power is essential for providing mission-critical services. Whether it s a hospital providing critical
More informationVLT HVAC Drive. Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification. Section 15172
VLT HVAC Drive Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification I. PART 1- GENERAL A. DESCRIPTION Section 15172 1. This specification covers complete a variable frequency drives
More informationDosimeter Setting Device System NRZ
User s Manual Dosimeter Setting Device System NRZ For Dosimeter NRF series (Units: msv Version:0.26 English) TA5C0903 b 1 / 50 Preface Thank you for purchasing the Dosimeter Setting Device; a product by
More informationLexium 05 motion control
00 0 V single-phase supply voltage Servo drive/servo motor combinations Lexium 0A or 0B servo drive/brh or BSH servo motor combinations Servo motors Lexium 0A and 0B servo drives 00 0 V single-phase supply
More informationDIVISION 15 - MECHANICAL. Section Variable Frequency Drives. Introduction
DIVISION 15 - MECHANICAL Section 15870 Variable Frequency Drives Introduction This specification is to cover a complete variable frequency motor drive (VFD) consisting of a pulse width modulated (PWM)
More informationRLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.
RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,
More informationSNJB College of Engineering Department of Computer Engineering
1. Intel s programmable device (8253) facilitates the generation of accurate time delays. a) counter b) timer c) both a & b d) none of these 2. The programmable timer device (8253) contains three independent
More informationUsing a previously saved session Select a route Route direction and guiding pop-up
Content A word from the product manager...4 1. Product composition...4 2. Charging the battery...4 3. Switch on and set the product...4 4. Installing the heart rate monitor belt...5 5. Key functions...5
More informationNOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION
COLLECTIVE VENTILATION NOE LOBBY RANGE NOE LOBBY 4 4 C - 1/2 hrs CMV/Collective extraction units Flow rate 4 to 114 m 3 /h 4 4 COLLECTIVE VENTILATION Ventilation unit PULLEY/BELT TRANSMISSION 4 to 114
More informationuser manual VFD 4X control panel INSTALLATION - OPERATION
user manual VFD 4X control panel INSTALLATION - OPERATION Z1080818 M03-171B ISSUED 11/2018 07/2014 READ READ AND UNDERSTAND UNDERSTAND THIS MANUAL THIS MANUAL PRIOR PRIOR TO OPERATING TO OPERATING OR SERVICING
More informationSED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options
SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency
More informationComfort, the Intelligent Home System. Comfort Scene Control Switch
Comfort, the Intelligent Home System Comfort Scene Control Sitch Introduction...1 Specifications...3 Equipment...3 Part Numbers...3 Identifying the SCS Version...4 Contents...4 Assembly...4 Settings...5
More informationSST Series Digital Thermostats Modbus Network Communication Guide
Modbus Guide UG6.90C Product SST SST Series Digital Thermostats Modbus Network Communication Guide UG6.90C - 1/5 MODBUS OVERVIEW MODBUS REGISTERS REGISTER WRITES (FUNCTION CODE 6) The SST thermostats can
More informationVariable Frequency Drives
Variable Frequency Drives Date : Feb 09, 2015-07:30 AM - Feb 10, 04:30 PM Event URL : http:///events/variable-frequency-drives-feb-2015-rochester- Organizer : American Traincoâ Venue : Location : Rochester
More informationRLS /M MX SERIES
The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above
More informationNC DOUBLE OPPOSING HEAD DRILL
NC DOUBLE OPPOSING HEAD DRILL 720ATD 720ATD 1800 x 1100 mm 2600 x 1600 mm 3000 x 2200 mm 3000 x 2600 mm 1. GENERAL PERFORMANCE 720ATD/20 Maximum glass dimension 3000 x 2600 Total weight Maximum Glass weight
More informationRiGO801 Laboratory Requirements
RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4
More informationQUICK SETUP GUIDE SECULIFE DFBASE
QUICK SETUP GUIDE SECULIFE DFBASE SECULIFE DFBASE is a microprocessor-based instrument that is used in the testing of defibrillators. It measures the energy output and provides information about the defibrillator
More informationSpaceControl for automated glucose control
SpaceControl for automated glucose control Instructions for use g Valid for software I9305_C Contents Contents 1 About this document...4 1.1 Purpose... 4 1.2 Additional valid instructions for use... 4
More informationSYSTEM RANGE DOMESTIC RANGE
CONTROL - SYSTEM WHITE ONE-WAYSWITCHES GW 20 571-16AX 1P - GW 20 572-16AX 1P - Backlit GW 20 583-16AX 1P - GW 20 503 2P - 16AX - GW 20 504 2P - 16AX - Backlit - GW 20 584 2P - 16AX - GW 20 005 2P - 10AX
More informationCerus P-Series General Specifications Section 15172
Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178
More informationTechnical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives
This Technical Tip assists users in applying Yaskawa iqpump1000 and iqpump Micro products to pump systems and provides useful information on: running without a transducer fixing Fdb-L or Feedback Loss
More informationAMBCO 1000+P AUDIOMETER
Model 1000+ Printer User Manual AMBCO 1000+P AUDIOMETER AMBCO ELECTRONICS 15052 REDHILL AVE SUITE #D TUSTIN, CA 92780 (714) 259-7930 FAX (714) 259-1688 WWW.AMBCO.COM 10-1004, Rev. A DCO 17 008, 11 13 17
More informationHanwell Instruments Ltd. Instruction Manual
Hanwell Instruments Ltd Instruction Manual Document Title RL5000 Sensors - User Guide Document No. IM4177 Issue No. 3 Hanwell Instruments Ltd 12 Mead Business Centre Mead Lane Hertford SG13 7BJ UNITED
More informationRaySafe i3 INSTALLATION & SERVICE MANUAL
RaySafe i3 INSTALLATION & SERVICE MANUAL 2017.06 Unfors RaySafe 5001104-1.1 All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical
More informationVMA Demo Unit. Introduction. This document provides information on how to set up and operate the VMA Demo Unit. Figure 1: VMA Demo Unit
Application Specific Controllers Technical Manual 636.3 VMA Controller Section Technical Bulletin Issue Date 0199 VMA Demo Unit Introduction This document provides information on how to set up and operate
More informationRLS /M MX SERIES
RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.
More informationArt " colour display videophone
27 mm 144 mm 182 mm BUS1 BUS2 GND +12VM GND +VAUX C NO -DOL +DOL AL-LB GND LB AL SW SW1 1 2 3 4 5 6 7 8 SW1 1 2 3 4 5 6 7 8 1 2 3 4 SW3 1 2 3 4 SW3 VR1 PT3 PT2 PT1 SW1 Fig. 1 Fig. 2 DESCRIPTI An intelligent
More informationS201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.
ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker
More informationActivant Acclaim. Using smit and p21adm. AIX suite: course 3 of 3
Activant Acclaim Using smit and p21adm AIX suite: course 3 of 3 Objectives Use smit p21 Including specific menus and their operation Access p21adm SMIT An acronym for System Management Interface Tools
More informationSleep Apnea Therapy Software Clinician Manual
Sleep Apnea Therapy Software Clinician Manual Page ii Sleep Apnea Therapy Software Clinician Manual Notices Revised Notice Trademark Copyright Sleep Apnea Therapy Software Clinician Manual 103391 Rev A
More informationStandard Products ACT15530 CMOS Manchester Encoder / Decoder May 16, 2005
Standard Products ACT15530 CMOS Manchester Encoder / Decoder www.aeroflex.com/avionics May 16, 2005 FEATURES MIL-STD-1553 Compatible 1.25 Megabit/sec Maximum Data Rate Sync Identification and Lock-in Clock
More informationINSTRUCTION MANUAL PIPELINE-PRO.CO.UK
INSTRUCTION MANUAL PIPELINE-PRO.CO.UK 01 PIPELINE PRO Manufactured in Germany, The PIPELINE PRO is a variable wattage e-cigarette available in two sizes to fit either the 18500 or 18650 battery. We recommend
More informationArt. 6272N 3.5" colour display videophone
27 mm 144 mm 1 182 mm +VD +20 V1 V/V2 GNDV L LB AL DOL EXTC S1 S2 COM 2 3 DSW1 DSW2 4 5 PT3 PT2 6 7 8 PT1 VR1 SW1 Fig. 1 ART. 6272N VX2200 6200 SERIES VIDEOPHONE FOR SYSTEMS USING COMPOSITE VIDEO SIGNAL
More informationACCELERATOR OWNER'S MANUAL
ACCELERATOR OWNER'S MANUAL Accelerator Series Instruction Manual Table of Content Introduction pg. 3 Buttons pg. 3 Major Functions Modes: pg. 4 Menu System pg. 4 Home Time Display pg. 4 Dual Time View
More informationWelcome! With a little effort you can have a big effect
Pausit version 1.9 User Guide Welcome! Copyright 2014 Pausit AB medföljer programvaran Pausit With a little effort you can have a big effect Life today, both at work and play, demands a constant fast pace,
More informationPROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1
.1. Overview P-1-1.2. PROFIBUS Converter/Repeater P-2-1.3. PROFIBUS Gateway P-3-1.4. PROFIBUS Remote I/O Modules P-4-1.5. PROFIBUS I/O Unit P-5-1 Overview.1. Overview PROFIBUS (Process Field Bus) is a
More informationMCC Human Machine lnterface
MCC Human Machine lnterface User Manual - Version 1.0 Corporate Office: 1349 Jacobsburg Road, Wind Gap, PA 18091 Production Facility: 3370 Fox Hill Road, Easton, PA 18045 Sales: 800.642.9396 Email: sales@icscarwashsystems.com
More informationSIPROTEC. Overcurrent Time Protection 7SJ80. Motor Protection 7SK80. Preface. Table of contents. Data in the PROFIBUS DP messages 1
Preface SIPROTEC Overcurrent Time Protection 7SJ80 Table of contents Data in the PROFIBUS DP messages 1 Standard mapping 3-1 2 Standard mapping 3-2 3 Index Motor Protection 7SK80 Communication Modules
More informationUser Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW
User Manual 2010 Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW Home Phone Connect Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now
More informationE2 Programming Start Up Guide for the M400 drive.
E2 Programming Start Up Guide for the M400 drive. 6 Necessary Applications Condenser M400 Drive VFD Status VFD Control Reset VFD Health VFD PCT HZ Added Application to Reduce Energy and Increase Life Cycle
More informationversion User s Guide nnnnnnnnnnnnnnnnnnnnnn AUTOMATIC POULTRY SCALES BAT2 Lite
version 1.02.0 User s Guide nnnnnnnnnnnnnnnnnnnnnn AUTOMATIC POULTRY SCALES BAT2 Lite 1. INTRODUCTION... 2 1.1. Scales Description... 2 1.2. Basic Technical Parameters... 2 1.3. Factory Setup of the Scales...
More informationRL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw
RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more
More informationPower Xpert FMX Operation of the busbar earthing panel
Operation of the busbar earthing panel User Manual 6101.599 G01 03 User Manual Power Xpert FMX Operation of a busbar earthing panel 6101.599 G01 03 English language Eaton Industries (Netherlands) B.V.
More informationBeltone Solus Pro 1.9 Fitting Guide
Beltone Solus Pro 1.9 Fitting Guide Table of Contents Table of Contents... 2 Getting started... 3 Start Screen... 3 Assigning Devices... 4 Connection Process... 5 MSG Calibration... 5 Gain Adjustment...
More informationDatasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA
More informationVariable Speed Drive Specification
Variable Speed Drive Specification Part 1 General A. Description 1. This specification describes an AC variable speed Direct Torque Control or sensorless vector equivalent drive (VFD) used to control the
More informationRLS /E-EV MX SERIES
RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,
More informationSED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass
Document No. 129-405 SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Product Description The SED2 VFD NEMA Type 3R/3RHE, Bypasses are companion packages for the family of SED2
More informationLiquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More information510Ic Owner s Manual CONSOLE OVERVIEW & GENERAL NOTES CONSOLE KEYPAD FUNTION
CONSOLE OVERVIEW & GENERAL NOTES A primary feature of the 510Ic is the ability to control and monitor the user s workout program via the brilliant LCD console. At any time, the user may view their speed,
More informationSystem Multiplexer / Permissive Module
System Multiplexer / (Cat 2030-MLXxxx-SYSx) ATTETIO: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: rior to beginning the installation and wiring process,
More informationFrequently Asked Questions
Frequently Asked Questions How does the SMRT-Y work? The SMRT-Y sensor accurately measures the moisture level in the soil. When the soil is dry, the SMRT-Y allows the irrigation controller to water as
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.
More information3100 & 7200 Programming Sheet V2.6
3100 & 7200 Programming Sheet V2.6 Main Board Version: V1.88B for 3100 & V1.8A PC for 7200 (voice) GSM Board Version: GSM V1.5A Enter Installer Programming Mode: [ Ж ] + [ MODE ] + [ 5 digits Installer
More informationDesktop Fitting Guide for Phonak Brio 3
Phonak Target 5.3.3 Desktop Fitting Guide for Phonak Brio 3 The Phonak Target fitting software is intended to be used by qualified hearing care professionals to configure, program, and fit hearing aids
More informationTechnical Data Sheet SONOFLOW CO.55/xxx(H) V2.0
The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on
More informationPortable Equine Nebuliser System. User Manual
Portable Equine Nebuliser System User Manual Table of Contents INTENDED USE... 3 SAFETY INFORMATION... 3 TECHNICAL SPECIFICATION... 4 INSTRUCTIONS FOR USE... 6 MAINTENANCE... 12 TROUBLESHOOTING... 13 WARRANTY...
More informationSiemens Parts SIPROTEC. Overcurrent Time Protection 7SJ80. Motor Protection 7SK80. Voltage and Frequency Protection 7RW80. Preface.
Preface SIPROTEC Overcurrent Time Protection 7SJ80 Motor Protection 7SK80 Table of contents Data in the PROFIBUS DP messages 1 Standard mapping 31 2 Standard mapping 32 3 Standard mapping 33 4 Index Voltage
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationUser s Manual for Eclipse(AccuCap)
InnoCaption Agent Program User s Manual for Eclipse(AccuCap) VER 2.1.4 InnoCaptionAgent Ver 2.1.4 2015-10-12 InnoCaption 1 / 24 InnoCaption Agent User s Manual for Eclipse Table of Contents 1. GENERAL...
More informationBruker D8 Discover User Manual (Version: July 2017)
University of Minnesota College of Science and Engineering Characterization Facility Eulerian cradle Reference 2θ (two-theta): Detector angle (GADDS angle # 1) Bruker D8 Discover User Manual (Version:
More informationResting and Stress ECG
Operating Manual Resting and Stress ECG 1 Safety 2 Hardware 3 Software 4 Hygiene Part 3: Operating characteristics: custo diagnostic 5.0 and higher for Windows MSW 0001 DK 1660 Version 002 13/06/2018 2018
More informationTriAuto mini Compact, Cordless Endodontic Handpiece
TriAuto mini Compact, Cordless Endodontic Handpiece Thinking ahead. Focused on life. Lightweight with Compact Head and Body The refined, compact design of TriAuto mini s head and body is very small and
More informationI AM SAFER. Reliable X-ray technology that reduces radiation exposure
I AM SAFER Reliable X-ray technology that reduces radiation exposure EN 40 cm / 80 cm / 110 cm (16 / 31 / 43 ) 70 cm (27 ) 9 cm (3,5 ) 36 cm (14 ) 79 cm / 119 cm / 149 cm (31 / 46 / 59 ) 87 cm (34 ) 81
More informationPhonak Fast Facts. Audéo B-Direct
Phonak Fast Facts Audéo B-Direct Phonak is introducing Audéo B-Direct, a new extension of the successful RIC hearing aid family for mild to severe hearing loss. Powered by Phonak Belong technology, Phonak
More informationPIPELINE PRO 2 MANUAL
PIPELINE PRO 2 MANUAL PIPELINE-PRO.CO.UK 01 PIPELINE PRO 2 The PIPELINE PRO 2 is a German made high-end mod for use with 18650 batteries and has 5 different modes. Variable Watt, Temperature Control (with
More informationRooter S. Compact, Cordless Endodontic Motor
EN Rooter S Compact, Cordless Endodontic Motor Lightweight with compact head and body The refined, compact design of Rooter S head and body is very small and lightweight. With this motor, the dentist can
More informationOperation Manual for Audiometer
Operation Manual for Audiometer PDD-401 0197 PISTON Ltd. 1121 Budapest Pihenő út 1. C pavilon v.3.080 Table of Content TABLE OF CONTENT...1 QUICK PREVIEW...3 INSTALLATION...3 DAILY ROUTINE...4 ICON DESCRIPTIONS...5
More informationRLS /E MX SERIES
RLS 310 610/E MX SERIES The RLS/E-MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,
More informationHRM Triax 15 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.
1 Information is power. HRM Triax 15 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition. Used properly this heart rate monitor will
More informationMonitor Instructions for Models: CHB-R6 CHB-UV6
Monitor Instructions for Models: CHB-R6 CHB-UV6 Power supply: output DC 9v/ 1000mA transformer adaptor TABLE OF CONTENTS Function Buttons ----------------------------------------------------------------------------
More informationLexium 05 Servo Drives. Motion control The high concentrate solution for your machines
Lexium 05 Servo Drives Motion control The high concentrate solution for your machines Lexium 05 Servo Drives Leveraging ingenuity and intelligence for ease of use Top grade performance With this new generation
More informationCROS System Initial Fit Protocol
CROS System Initial Fit Protocol Our wireless CROS System takes audio from an ear level microphone and wirelessly transmits it to the opposite ear via Near-Field Magnetic Induction (NFMI) technology, allowing
More informationAC CENTRIFUGAL FORWARD CURVED FAN 133 x 190
Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double
More informationCONSOLE GUIDE & SET-UP INSTRUCTIONS
CONSOLE GUIDE & SET-UP INSTRUCTIONS TABLE OF CONTENTS MTX Console Guide Console Features... 1 Dynamic Display (LCD)... 2 Keypad Buttons... 5 Software Management... 7 Optional Accessories... 8 CROSS CiRCUIT
More informationMedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator
MedRx HLS Plus An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid Hearing Loss Simulator The Hearing Loss Simulator dynamically demonstrates the effect of the client
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationGLOOKO FOR ios MIDS USER GUIDE
GLOOKO FOR ios MIDS USER GUIDE October 2018 IFU-0001 13 Glooko MIDS is cleared for US only Rx only TABLE OF CONTENTS TABLE OF CONTENTS MOBILE INSULIN DOSING SYSTEM (MIDS)... 2 Intended Use... 2 Warnings...
More informationLabVIEW PROFIBUS VISA Driver DP-Master
LabVIEW PROFIBUS VISA Driver DP-Master Getting Started V1.35 27.04.2017 Project No.: 5303 Doc-ID.: LabVIEW PROFIBUS VISA Driver KUNBUS d:\project\5302_df_profi_ii\anwenderdoku\labview\version 1.35\gettingstarted_win_dp-master_e.doc
More information