Modern Hadron Therapy Gantry Developments. 16th Jan 2014
|
|
- Herbert Boyd
- 5 years ago
- Views:
Transcription
1 Modern Hadron Therapy Gantry Developments 16th Jan 2014
2 Protect, Enhance, and Save Lives IBA ProteusONE
3 THE TREND: MORE COMPACT, CHEAPER Access to PT is key ProteusPLUS ProteusONE ft² / 1672 m² 3600 ft² / 334 m²
4 PROTEUS ONE, THE SAFEST WAY TO COMPACT IMPT Proven Proteus PBS Technology IGPT - Enabled Patient and Staff Centric ALARA Neutron Sources Shielded Small footprint Patient and Staff Centric Pencil Beam Scanning
5 PROTEUS ONE, THE SAFEST WAY TO COMPACT IMPT IMPT powered by PBS 3D Cone-Beam CT* Image- Guided PT Patient and staff-friendly open environment
6 Protect, Enhance, and Save Lives The early concept
7 TREATMENT MODE SPECIFICATIONS Treatment mode Type Active Scanning allowing at least lateral multiple repainting and potentially volumetric repainting Field size 20 cm X 20 cm minimum à 20 X 25 cm ideally with 25 cm in the Y direction (// to the axis of the GTR or horizontal in a FBR) Patching fields Yes (and well managed by TPS and PTS) Distal fall-off Maximum 2 mm above physical limit Lateral Penumbra (spot size) No degradation compare to Proteus 235 Several Spot Tune ID Yes to increase the spot size when needed (same Proteus 235) Treatment time No degradation compare to Proteus 235 / at least (1 liter, 2 min, 2 gray) and the goal will remain at 1 min Dose Accuracy No degradation compare to Proteus 235 SAD At least 2 m Range and modulation Max range is 32 gr/cm² Min range will be 0.5 g:cm² with the use of accessories for ranges lower than 7.5 gr/cm² and to keep the width of any proton peak always equal or greater than 5 mm. Accessory Holder An accessory drawer must be installed at the end of the nozzle It will be remotely controlled as to a) tune the distance between the drawer and isocenter b) insert / retract the accessory in the beam path
8 The Early sketch (Summer 2009)
9 SCANNING PROPERTIES Final magnet EFB at 120 cm from patient Combined scanning magnet upstream Treatment field of 22 x 25 cm at isocenter Pole faces of the 60 magnet adjusted to have an identical SAD of 3.15 m in both H & V planes (changed later) Ion chambers and telescopic accessory drawer on the exit of the last 60 dipole
10 ProteusPLUS 1 ROOM ONLY provides simplification opportunities 55.8 ft / 17 m 62.3 ft / 19 m
11 COMBINING THE ESS IN THE GANTRY
12 SIZE COMPARISON ProteusPLUS ProteusONE ft² / 1672 m² 3600 ft² / 334 m²
13 Protect, Enhance, and Save Lives Development
14 IT STARTED WITH OPTICS Combining ESS and gantry was never done before Q 1 G 1 Q 2 G 1 B 1 G 1 Q 3 G 1 Q 4 G 1 Q 5 G 1 Q 6 G 1 Q 7 G 1 B 2 G 1 B 2 G 1 B 3 G 1 D E G R P 1 G 1 S L I X S L I Y P 2 G 1 S L I T P 4 G 1 S C A N I C 1 I S O C Doubly achromatic Dispersion: ~3 cm/%
15 AND A FIRST LARGE GAP MAGNET MODEL Upstream scanning was new to IBA This magnet is key for gantry dimensioning (and power)
16 IT QUICKLY BECAME MORE COMPLICATED «Compact» also means new problems to solve New magnets: Rotating quads, stronger than standard quads Scanning magnets Bending magnets models Spot size vs. scan angle and magnet crosstalk! MT23 Poster & article Gantry structure Impact on instrumentation Stray fields
17 AT A GLANCE Scan magnets and quads Scanning magnets Combined XY vs. twins Compactness, field quality & power consumption => Two magnets selected Entrance rotating quads optimization Small diameter Grooves are for pipings
18 AT A GLANCE Bending magnets : 1.5 m radius, small gap, 1.53 T, #blocks 60 : 1.6m radius, large gap, 1,4 T
19 INTEGRATED INTO GANTRY It is crowded but everything fits in
20 IN THE MEANTIME Industrialization Subcontracting Integration of imaging V&V as well as QC procedures Patient enclosure Procurement plan for the next ones!
21 Protect, Enhance, and Save Lives Patient experience (colors)
22 PATIENT CHOOSES THEME MEDICAL ENV. AS USUAL Welcome Set-up Prepare Irradiation
23 PATIENT CHOOSES THEME THE PATIENT CHOOSES! Welcome Set-up Prepare Irradiation
24 PATIENT CHOOSES THEME DESIGNED FOR KIDS Welcome Set-up Prepare Irradiation
25 Protect, Enhance, and Save Lives Integration Belgium - Shreveport
26 ASSEMBLY, MECHANICS AND INTEGRATION IN BELGIUM Mechanics integration, GRF, cabling, testing shipping in a single box
27 TRANSPORT AND RIGGING Shipment in October 13 - Here s the box
28 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
29 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
30 Shreveport Rigging SHREVEPORT RIGGING Protect, Enhance, and Save Lives
31 Shreveport Rigging SHREVEPORT RIGGING Protect, Enhance, and Save Lives
32 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
33 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
34 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
35 SHREVEPORT RIGGING Protect, Enhance, and Save Lives
36 Protect, Enhance, and Save Lives Integration Beam tests started
37 MECHANICS & ROTATION
38 1ST End December On second shift because of an unfortunate beam dump!
39 CURRENT STATUS Now, we re busy with models vs. experiment crosschecks (we have to deal with ESS = losses along the line => beam size) Approvals and commisionning (CGBL FDA filing OK) => Multi-site, multi department and interdisciplinary teamwork 1st patient expected before ASTRO 2014 which means: exactly 5 years after first concept drawings!
40 THANK YOU FOR YOUR ATTENTION
Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne
Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne Terry Wu, Ph.D. Chief Physicist, Radiation Oncology Department Willis-Knighton Cancer Center/Proton Therapy Center Shreveport,
More informationLearning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan
Overview of Quality Assurance in Proton Therapy Omar Zeidan AAPM 2012 Charlotte, NC July 30 st, 2012 Learning Objectives Understand proton beam dosimetry characteristics and compare them to photon beams
More informationHeavy Ion Tumor Therapy
Heavy Ion Tumor Therapy Applications Bence Mitlasoczki 25.06.2018 Heidelberg 1. Source (H 2 /CO 2 ) 2. Linac 3. Synchrotron 4. Guide 5. Treatment rooms 6. X-ray system 7. Gantry 8. Treatment room with
More informationJefferies Healthcare Conference
Jefferies Healthcare Conference Jean-Marc BOTHY - CSO June 8, 2017 2017 IBA SA Disclaimer This presentation may contain forward-looking statements concerning industry outlook, including growth drivers;
More informationProton Beam Therapy at Mayo Clinic
Proton Beam Therapy at Mayo Clinic Jon J. Kruse, Ph.D. Mayo Clinic Dept. of Radiation Oncology Rochester, MN History of Proton Therapy at Mayo 2002: Decided to consider particle therapy analysis and education
More informationThe Heidelberg Ion Therapy Center. Thomas Haberer Heidelberg Ion Therapy Center Hadron Therapy Workshop, Erice 2009
The Heidelberg Ion Therapy Center Thomas Haberer Heidelberg Ion Therapy Center Hadron Therapy Workshop, Erice 2009 Goal The key element to improve the clinical outcome is local l control! entrance channel:
More informationPlans for the Precision Cancer Medicine Institute University of Oxford
Plans for the Precision Cancer Medicine Institute University of Oxford STFC & Particle Accelerators and Beams group workshop on particle accelerators for medicine 17 th February 2015 Claire Timlin The
More informationProton Treatment. Keith Brown, Ph.D., CHP. Associate Director, Radiation Safety University of Pennsylvania
Proton Treatment Keith Brown, Ph.D., CHP Associate Director, Radiation Safety University of Pennsylvania Proton Dose vs. Depth Wilson,. R.R. Radiological use of fast protons. Radiology 47:487-491, 1946.
More informationCharacterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning
Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning Supervisors Prof. V. Patera PhD R. Van Roermund Candidate Annalisa Patriarca
More informationH. Röcken, M. Abdel-Bary, E. Akcöltekin, P. Budz, T. Stephani, J. Wittschen
: Medical Operation of the 2 nd Machine, Production and Commissioning Status of Machines No. 3 to 7 H. Röcken, M. Abdel-Bary, E. Akcöltekin, P. Budz, T. Stephani, J. Wittschen VARIAN Medical Systems Particle
More informationThe first year of operation of PSI s new SC cyclotron and beam lines for proton therapy.
The first year of operation of PSI s new SC cyclotron and beam lines for proton therapy. Marco Schippers, Jürgen Duppich, Gudrun Goitein, Eugen Hug, Martin Jermann, Anton Mezger,Eros Pedroni, for the PROSCAN
More informationSUMITOMO Particle Therapy Technologies
55 th AAPM annual meeting Particle Beam Therapy Symposium SUMITOMO Particle Therapy Technologies August 3, 2013 Yukio Kumata Experience accelerators for science Current Status proton and carbon Future
More informationPractical Challenges and Opportunities for Proton Beam Therapy. M. F. Moyers Loma Linda University Medical Center
Practical Challenges and Opportunities for Proton Beam Therapy M. F. Moyers Loma Linda University Medical Center Outline I. Introduction II. Registration and Immobilization III. Beam Shaping IV. Localization
More informationEfficient Dosimetry for Proton Therapy
Efficient Dosimetry for Proton Therapy Why IBA Dosimetry? IBA Dosimetry offers the full product range tailored to fit any Proton Therapy QA needs. PT treatment safety, as well as most efficient dosimetry
More informationProf. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center
The Heidelberg Ion Beam Therapy Center A Hospital-based Facility Dedicated to Precision and Flexibility Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center Carbon Ion Therapy
More informationABSTRACTS. of the NIRS International Seminar on the Heavy Charged Particle Therapy for Cancer and the XXVII PTCOG MEETING.
P ROTON THERAPY C O- OPERATIVE GROUP Chair Michael Goitein Ph. D. Department of Radiation Oncology Massachusetts General Hospital Boston MA 02114 (617) 724-9529 (617) 724-9532 Fax Secret ary Janet Sisterson
More informationPlanning for the Installation of a Compact Superconducting Proton Therapy Unit in a Busy Medical Center Environment
Planning for the Installation of a Compact Superconducting Proton Therapy Unit in a Busy Medical Center Environment Barry W. Wessels, Ph.D. Director of Medical Physics and Dosimetry Case Western Reserve
More informationCOMPACT IMAGE-GUIDED IMPT SOLUTION PROTON THERAPY MADE EASY.
ProteusONE COMPACT IMAGE-GUIDED IMPT SOLUTION PROTON THERAPY MADE EASY www.iba-proteusone.com PROTON THERAPY. A TRUE SUCCESS IN CANCER CARE Proton therapy is used today to treat many cancers and is particularly
More informationThe Advantages of Particle Therapy and the Status of the Heidelberg Iontherapy Center
The Advantages of Particle Therapy and the Status of the Heidelberg Iontherapy Center Thomas Haberer, Scientific Technical Director, Heidelberg Ion Therapy Center Situation / Indications 2/3 patients suffer
More informationTraceability and absorbed dose standards for small fields, IMRT and helical tomotherapy
Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy Simon Duane, Hugo Palmans, Peter Sharpe NPL, UK Stefaan Vynckier UCL, Brussels, Belgium LNE-LNHB / BIPM workshop,
More informationPresent Status and Future Developments in Proton Therapy
Present Status and Future Developments in Proton Therapy Alfred R. Smith Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030,
More informationThe Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation. Presented at EPAC 2008, Genova D. Ondreka, GSI
The Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation Presented at EPAC 2008, Genova D. Ondreka, GSI Introduction Heidelberg Ion Therapy Centre: Europe's first dedicated particle therapy facility
More informationDiscuss the general planning concepts used in proton planning. Review the unique handling of CTV / ITV / PTV when treating with protons
Mark Pankuch, PhD Discuss the general planning concepts used in proton planning Review the unique handling of CTV / ITV / PTV when treating with protons Pencil Beam distributions and PBS optimization Cover
More informationUnrivaled, End-to-End
PHANTOMS Unrivaled, End-to-End Stereotactic QA Industry-leading 0.1mm accuracy minimizes errors at each link in the stereotactic quality assurance chain. Stereotactic radiosurgery (SRS) is governed by
More informationSemiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry
DETECTORS Always perfectly oriented. Semiflex 3D 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry The New Reference Class Full 3D Geometry For FFF and FF Beams Semiflex 3D 3D Detector
More informationRoad Map for the development of hadron therapy and associated nuclear medicine methods at JINR:
НТС ОЭЗ, 07 октября 2011 Road Map for the development of hadron therapy and associated nuclear medicine methods at JINR: Development of 3D conformal Proton therapy Design of various devices for proton
More informationSemiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry
DETECTORS Always perfectly oriented. Semiflex 3D 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry The New Reference Class Full 3D Geometry For FFF and FF Beams Semiflex 3D 3D Detector
More informationBeam Loss and Collimation in the ESS Linac
Beam Loss and Collimation in the ESS Linac Ryoichi Miyamoto (ESS) B. Cheymol, H. Danared, M. Eshraqi, A. Ponton, J. Stovall, L. Tchelidze (ESS) I. Bustinduy (ESS-Bilbao) H. D. Thomsen, A. I. S. Holm, S.
More informationCustom-Made Products / Scientific Research Instruments
Synchrotron Radiation Instruments Double Crystal Monochromator A double crystal monochromator is an instrument that extracts light of a specific wavelength using crystal diffraction. Light of various wavelengths
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Laser Cutting Head BIMO-FSC for Flexible Flat Sheet Cutting The use of fibre lasers for cutting applications is growing steadily. The
More informationStatus of Proton Therapy: results and future trends
Status of Proton Therapy: results and future trends E. Pedroni Paul Scherrer Institute Division of Radiation Medicine CH-5232 Villigen PSI Abstract The number of centres investigating proton therapy in
More informationApplication(s) of Alanine
Application(s) of Alanine Simon Duane Radiotherapy Standards User Group, 5 June 2007 Outline Alanine/EPR dosimetry characteristics, usage (dis)advantages for reference dosimetry Traceable dosimetry for
More informationThe Heidelberg Ion Therapy Center and PARTNER. Thomas Haberer Heidelberg Ion Therapy Center
The Heidelberg Ion Therapy Center and PARTNER Thomas Haberer Heidelberg Ion Therapy Center Goal The key element to improve the clinical outcome is local control! entrance channel: low physical dose low
More informationIntegrating the Radixact into a Highly Comprehensive Center
Integrating the Radixact into a Highly Comprehensive Center Alonso N. Gutiérrez, PhD, MBA ASTRO Meeting 2018 Disclosures An honorarium is provided by Accuray for this presentation (donated) Accuray and
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Modules 40 Laser light cable receiver Cover slide in front of collimation 9 46,5 0,2 86,5 64,4 2,5 131,2 Collimation module with manual
More informationIII. Proton-therapytherapy. Rome SB - 5/5 1
Outline Introduction: an historical review I Applications in medical diagnostics Particle accelerators for medicine Applications in conventional radiation therapy II III IV Hadrontherapy, the frontier
More informationIntroduction to Ion Beam Cancer Therapy
Introduction to Ion Beam Cancer Therapy Andrew M. Sessler (with some slides from David Robin) Lawrence Berkeley National Laboratory Berkeley, CA 94720 Cyclotron 10, Lanzhou September 10, 2010 Contents
More informationIMPT with Carbon Ions
IMPT with Carbon Ions PTCOG 48, Heidelberg, 28.09.-03.10.2009 Malte Ellerbrock Medical Physics Expert Heidelberg Ion-Beam Therapy Center HIT Betriebs GmbH am Universitätsklinikum Heidelberg http://www.hit-centrum.de
More informationAccelerator Seminar, April 2013
, H. Röcken VARIAN Medical Systems Particle Therapy GmbH Friedrich-Ebert-Str. 1 D-51429 BERGISCH GLADBACH GERMANY OUTLINE Why having a Superconducting Cyclotron? Some Basics VARIAN PT Cyclotrons: ProBeam
More informationWorkshop on Hadron Beam Therapy of Cancer Erice, Sicily April 24-May
IONTRIS Synchrotron based PT Solutions from Siemens AG Workshop on Hadron Beam Therapy of Cancer Erice, Sicily April 24-May 1 2009 Matthias Herforth VP Business Development and Communications Siemens AG
More informationWe bring quality to light. LGS 350 Goniophotometer
We bring quality to light. LGS 350 Goniophotometer The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination
More informationFirst Technology Safety Systems. Design Freeze Status. Flex-PLI-GTR Development
Based on TEG-047 29 Nov. 2007 JAMA-JARI JARI First Technology Safety Systems Design Freeze Status Flex-PLI-GTR Development Full Calibration Test Procedures Bernard Been FTSS Europe Comments addressed from
More informationSHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES
SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES MELISSA C. MARTIN, M.S., FACR, FAAPM PRESIDENT AAPM - 2017 PRESIDENT - THERAPY PHYSICS INC., GARDENA, CA MELISSA@THERAPYPHYSICS.COM AAPM Spring
More informationNew Treatment Research Facility Project at HIMAC
New Treatment Research Facility Project at Koji Noda Research Center for Charged Particle Therapy National Institute of Radiological Sciences IPAC10, Kyoto, JAPAN, 25th May, 2010 Contents 1. Introduction
More informationNuclear Associates
Nuclear Associates 37-013 GARD Users Manual March 2005 Manual No. 37-013-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective
More information*Chien-Yi Yeh, Ji-Hong Hong * 葉健一洪志宏
林口 Proton Therapy in Ti Taiwan *Chien-Yi Yeh, Ji-Hong Hong * 葉健一洪志宏 Chang Gung Memorial Hospital at Lin-Kou, Taiwan 林口長庚紀念醫院 OCPA2010 at Beijing, China Aug. 5, 2010 Outline 1. The principle of proton radiotherapy
More informationOnline Care, Online Control, Online Confidence
Online Care, Online Control, Online Confidence * Online Treatment Monitoring and much more! Designed for Efficiency provides you with online control and online confidence of treating your patients exactly
More informationph fax
This product is available through: JRT Associates www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 5 Nepperhan Avenue, Suite 2B 3120 Deming Way Middleton WIElmsford, 53562-1461 NY
More informationANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0
ANATOMIC Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0 SCREEN LAYOUT Take screenshot Surgical step Dynamic navigation zone Information area and buttons 2 SCREEN LAYOUT Indicates action when yellow
More informationPREDICTION OF ABSORBED DOSE DISTRIBUTIONS AND NEUTRON DOSE EQUIVALENT VALUES IN PROTON BEAM RADIATION THERAPY
PREDICTION OF ABSORBED DOSE DISTRIBUTIONS AND NEUTRON DOSE EQUIVALENT VALUES IN PROTON BEAM RADIATION THERAPY IDENTIFICATION NUMBER: ANS-RT-PROTON-01 BENCHMARK CLASSIFICATION: Radiation Therapy BENCHMARK
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC Optical System Perfectly Focused on Highest Productivity The BIMO-FSC s optical system is set-up modularly. This provides different options for
More informationCovator The Height-Adjustable Bucky Table with Integrated Mobile Column System
Covator The Height-Adjustable Bucky Table with Integrated Mobile Column System 1 Extremely high flexibility and effortless patient positioning thanks to the floating tabletop with height adjustment. Covator
More informationMS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for
More informationAspects of Industrialization of Accelerators for Particle Therapy ICABU, November 11, 2013, Daejeon
Aspects of Industrialization of Accelerators for Particle Therapy ICABU, November 11, 2013, Daejeon Introduction Why Particle Therapy? PT Milestones What is meant by Industrialization Examples Protons-only:
More informationAPPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS
APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination
More informationClinical Report for Wanjie Proton Therapy Center. Li Jiamin, MD Wanjie Proton Therapy Center
Clinical Report for Wanjie Proton Therapy Center Li Jiamin, MD Wanjie Proton Therapy Center General Information Wanjie Proton Therapy Center was founded in June 2001 The first patient was treated in Dec.
More informationState-of-the-art proton therapy: The physicist s perspective
State-of-the-art proton therapy: Tony Lomax, Centre for Proton Radiotherapy, Paul Scherrer Institute, Switzerland Overview of presentation 1. State-of-the-art proton delivery 2. Current challenges 3. New
More informationBruker D8 Discover User Manual (Version: July 2017)
University of Minnesota College of Science and Engineering Characterization Facility Eulerian cradle Reference 2θ (two-theta): Detector angle (GADDS angle # 1) Bruker D8 Discover User Manual (Version:
More informationSRT-100 Skin cancer TReaTmenT Simplified
SRT-100 Skin cancer treatment simplified More Patients, Few Choices Cases of skin cancer have been on the rise for decades, and are dramatically escalating as the population ages. According to the Centers
More informationProton Therapy Dosimetry & Clinical Implementation. Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine
Proton Therapy Dosimetry & Clinical Implementation Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine Outline» Proton Therapy Basics» Why Proton Therapy? (Dosimetric Superiority)»
More informationPAN CEPH 3D CONE BEAM
PAN CEPH 3D CONE BEAM 2D - 3D panoramic units PANORAMIC CEPHALOMETRIC 3D CONE BEAM IMAGING I-MAX TOUCH Tactile & naturally intuitive panoramic imaging Discover the simplicity and efficiency this unit can
More informationBICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:
BICOE Breast Imaging Center of Excellence What is it? - Requirements William Geiser, MS DABR Senior Medical Physicist MD Anderson Cancer Center Houston, Texas wgeiser@mdanderson.org ACR Accreditation in:
More informationWHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation
Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions
More informationOverview. Proton Therapy in lung cancer 8/3/2016 IMPLEMENTATION OF PBS PROTON THERAPY TREATMENT FOR FREE BREATHING LUNG CANCER PATIENTS
IMPLEMENTATION OF PBS PROTON THERAPY TREATMENT FOR FREE BREATHING LUNG CANCER PATIENTS Heng Li, PhD Assistant Professor, Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX, 773
More informationFlowmeters and. Specialty Products
Flowmeters and Specialty Products Chrome Flowmeter Durable, Accurate, Precise, Dependable 1MFA9005 4MFA1001 1MFA2001 1MFA1101 6MFA1001 1MFA3001 1MFA3501 1MFA1001 Specifications Model Gas Scale Increments
More informationSpiderX. Portable Residual Stress X-Ray Diffractometer.
Portable Residual Stress X-Ray Diffractometer www.gnr.it About SpiderX GNR Analytical Instrument offers equipment based on X-Ray Diffraction to measure residual stress state and retained austenite content.
More informationEvaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases
Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook
More informationUse of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments
Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments Alana Hudson *1 1 Tom Baker Cancer Centre, Department of Medical Physics, 1331
More informationInstallation Guide for ultrasonic transducers
Installation Guide for ultrasonic transducers 1 1. Welcome at systec Thank you very much for using deltawave. This document provides you with all necessary information to install the transducers accurately
More informationTreatment Planning (Protons vs. Photons)
Treatment Planning Treatment Planning (Protons vs. Photons) Acquisition of imaging data Delineation of regions of interest Selection of beam directions Dose calculation Optimization of the plan Hounsfield
More informationTHE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin
THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY S.V. Akulinichev, A. V. Andreev, V.M. Skorkin Institute for Nuclear Research of the RAS, Russia THE PROJECT OF NEUTRON SOURCES FOR THE NEUTRON
More informationIMAGE-GUIDED RADIATION THERAPY
IMAGE-GUIDED RADIATION THERAPY Your Single Source Oncology Solutions Provider Plan. Target. Treat. At Best NOMOS, we design products and solutions that help medical professionals treat a variety of cancers.
More informationIROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015
IROC Liver Phantom Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 The study groups are requests that each institution keep the phantom for no more than 2 weeks. During
More informationClinical Education A comprehensive and specific training program. carry out effective treatments from day one
Proton Therapy Clinical Education A comprehensive and specific training program carry out effective treatments from day one Forewarned is forearmed Although over 100,000 patients have been treated in proton
More informationA new geometric and mechanical verification device for medical LINACs
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 A new geometric and mechanical verification device for medical LINACs Keith T. Welsh,* Robert A. Wlodarczyk, and L. E. Reinstein
More informationDiode calibration for dose determination in total body irradiation
Iran. J. Radiat. Res., 2008; 6 (1): 43-50 Diode calibration for dose determination in total body irradiation M.Allahverdi 1*, Gh. Geraily 1, M. Esfehani 3,A. Sharafi 2,A. Shirazi 1 1 Department of Medical
More information8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit
MR-Linac is a research programme. It is not available for sale and its future availability cannot be guaranteed 8/2/2017 Clinical Implementation of an MR-Guided Treatment Unit Geoffrey S. Ibbott, Ph.D.
More informationRadiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada
Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Overview Introduction Overview Introduction Brachytherapy Radioisotopes in contact with the tumor Overview
More informationBICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives
BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation William Geiser, MS DABR Senior Medical Physicist MD Anderson Cancer Center Houston, Texas wgeiser@mdanderson.org 1 Introduction Objectives
More informationSCIENTIFIC AND TECHNOLOGICAL DEVELOPMENT OF HADRONTHERAPY
SCIENTIFIC AND TECHNOLOGICAL DEVELOPMENT OF HADRONTHERAPY SAVERIO BRACCINI * Albert Einstein Centre for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse
More informationTreatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize
More informationHelical tomotherapy radiation leakage and shielding considerations
Helical tomotherapy radiation leakage and shielding considerations John Balog a TomoTherapy Incorporated, 1240 Deming Way, Madison, WI 53717 and Department of Medical Physics, University of Wisconsin at
More informationBICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives
BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation William Geiser, MS DABR Senior Medical Physicist MD Anderson Cancer Center Houston, Texas wgeiser@mdanderson.org 1 Introduction Objectives
More informationIROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014
IROC Head and Neck Phantom Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014 The study groups are requesting that each institution keep the phantom for a period of time
More informationWe bring quality to light. LGS 1000 Goniophotometer
We bring quality to light. LGS 1000 Goniophotometer Instrument description Measurement options Spatial radiation patterns Luminous flux integration Specifications Key features at a glance Goniophotometer
More informationVerification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams
Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams Reduan A a, Mazurawati M b, Nur Iziana M a, Nik Ruzman NI b, Ahmad Z a and Ahmad Lutfi Y b a School of Health
More informationTHE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS
International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION
More informationPress release Regulated information
IBA TRADING UPDATE - THIRD QUARTER 2013 Pick up in revenues over H1 2013 due to good order book conversion Company on track to be selected for eight new proton therapy (PT) rooms in 2013 REBIT margin for
More informationProLift Product Line. Innovative aluminum patient hoist solutions. I lightweight I user-friendly I mobile I ergonomic
ProLift Product Line Innovative aluminum patient hoist solutions I lightweight I user-friendly I mobile I ergonomic www.novacare.de The ProLift Product Line The light solution for heavy tasks! The novacare
More informationDC-6. Diagnostic Ultrasound System
DC-6 Diagnostic Ultrasound System MINDRAY is proud to introduce DC-6, a color Doppler ultrasound system for general applications. DC-6 incorporates the latest digital ultrasound image processing technology
More informationResults of dose control and measurement plans applied for SPEAR3 commissioning year (FY04)
SLAC-PUB-12309 February 2007 Results of dose control and measurement plans applied for SPEAR3 commissioning year (FY04) Hesham Khater, James Liu, Alyssa Prinz, Jim Allan and Sayed Rokni Radiation Protection
More informationTHE BEST IN PROTON THERAPY TODAY AND TOMORROW
THE BEST IN PROTON THERAPY TODAY AND TOMORROW The figures speak for themselves As the leading provider of Proton Therapy, IBA is committed to making this advanced treatment available to cancer patients
More informationDebate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete
Austin, TX July 21, 2014 Debate Motion "Arc Based Techniques Will Make Conventional IMRT Obsolete AGAINST the Motion: Peter Balter, Ph.D. Potential Conflicts of Interest: Dr. Balter has research support/collaborations
More informationIBA Dosimetry Company Presentation. Patient Safety & Quality Control
IBA Dosimetry Company Presentation Patient Safety & Quality Control IBA Mission Protect, enhance and save lives Protect, Enhance, and Save Lives - 2 - The History of IBA Dosimetry A story of innovation
More informationSpecifics of treatment planning for active scanning and IMPT
Specifics of treatment planning for active scanning and IMPT SFUD IMPT Tony Lomax, Centre for Proton Radiotherapy, Paul Scherrer Institute, Switzerland Treatment planning for scanning 1. Single Field,
More informationMAGNUM FITNESS SYSTEMS : 5000 Series
MAGNUM FITNESS SYSTEMS : 5000 Series > POWER AND STYLE follow the lead Thirty years of industry experience, innovation and customer feedback result in aesthetics that draw users into exercise. Exceptional
More informationIMRT QA: Point Dose Measurements or 2D Array?
QA for IMRT IMRT QA: Point Dose Measurements or D Array? General Linac QA for IMRT MLC checks Dose linearity at low MU Patient-specific measurements Performed using various methods Purpose is to verify
More informationTriAuto mini Compact, Cordless Endodontic Handpiece
TriAuto mini Compact, Cordless Endodontic Handpiece Thinking ahead. Focused on life. Lightweight with Compact Head and Body The refined, compact design of TriAuto mini s head and body is very small and
More informationAssessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 1, 2015 Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit
More information