Kenny Guida, DMP, DABR March 21 st, 2015

Size: px
Start display at page:

Download "Kenny Guida, DMP, DABR March 21 st, 2015"

Transcription

1 Kenny Guida, DMP, DABR March 21 st, 2015

2 Breast Cancer Treatment planning and delivery Hypofractionation Trials Hybrid Planning History Techniques RTOG 1005 Trial Hybrid-VMAT Research project

3 3D Tangents Hard Wedges Not as popular these days Increase dose to contralateral breast Hot spots EDW, Virtual Wedge Limited in field size Collimator rotation and MLCs Field-in-Field Increasingly popular technique Use of multiple subfields can yield homogenous plan and reduce hotspots

4 3D Boost Wedge Pair Cone-down tangents 3 Field in some cases Electron Boost Single field Treat to % IORT Boost If positive margins, deliver WBRT postoperatively

5 Free breathing Use of 2+ cm of flash compensates for patient motion associated with breathing when treating patient with tangents Breathold becoming more popular these days effort to reduce heart dose in some patients Setup Wing board or Breast board Prone breast board seeing more implementation Imaging 2D matching with MV portal imaging 3D matching with OBI available on many linacs

6 Whole Breast 200cGy x 25 fx 180cGy x 25 fx 180cGy x 28 fx Boost 200cGy x 5 fx 200cGy x 8 fx

7 ASTRO 2013 Choosing Wisely Don t initiate whole breast radiotherapy as a part of breastconservation therapy in women 50 with early-stage invasive breast cancer without considering shorter treatment schedules.

8 Possibility of treating patients to a lower total dose in fewer fractions, but with increased dose per fraction as compared to the clinical norm Benefits: Patient convenience Shorter duration Lower cost for entire treatment Favorable rates of late effects and loco-regional tumor control

9 Potential holdups Early stage T1-T2, N0 (maybe N1) No chemotherapy Patient size Few trials with 10 years of follow up Not as much information and data available as standard fractionation Reimbursement system in US Conventional fraction efficacy Early and late effects? Prescribed dose and fractionation What works best? Trials in Canada/UK/US have different Rx doses, number of fractions, and boost/no boost

10 Typical Treatment Regimens: Canada (OCOG) 4272cGy in 16fx UK START A 4160cGy or 3900cGy in 13fx START B 4000cGy in 15fx Other Italy 4000cGy in 15fx WB + 300cGy x 3fx boost

11 Ontario Clinical Oncology Group OCOG 4250cGy in 16fx vs 5000cGy in 25fx 1234 patients HF vs CF N0, negative margins, invasive breast cancer with breast-conserving surgery Small to moderately sized breasts Shortened course did not compromise local tumor control 10 year risk of local recurrence was 6.2% with Hypofraction compared to 6.7% with conventional fractionation No observed differences in terms of overall survival or death due to breast cancer

12 RT after surgery, chemotherapy and endocrine treatment followed if prescribed Boost dose given at physician discretion START A UK 3900cGy or 4160cGy in 13fx vs 5000cGy in 25fx Moderate or marked breast induration, telangiectasia, and edema were significantly less common in 3900cGy group Normal tissue effects did not differ between 4160 and 5000cGy groups START B UK 40Gy in 15fx over 3 weeks for HF arm Small but significant improvement in rates of disease-free survival, mets, and overall survival when compared to CF Breast shrinkage, telangiectasia, and edema were significantly less common in 4000cGy group

13

14 Phase III Trial of Accelerated Whole Breast Irradiation with Hypofractionation plus Concurrent Boost vs. Standard Whole Breast Irradiation plus Sequential Boost for Early Stage Breast Cancer Patient population: Stage 0, I, II Breast cancer resected by lumpectomy ± neoadjuvant systemic therapy Arm 1: Standard fractionation WBRT 50Gy (25Fx x 2Gy) Optional hypofraction 42.7Gy (16Fx x 2.67Gy) Sequential boost 12Gy (6Fx x 2Gy) Optional boost of 14Gy (7Fx x 2Gy) Arm 2: Hypofractionation WBRT 40.05Gy (15Fx x 2.67Gy) Concurrent boost to 48Gy Gy (15Fx x 53cGy)

15 Goals of the protocol Evaluation of biological equivalence for both the whole breast and boost dose to the breast tissue Major focus - lumpectomy bed (highest risk for recurrence is area immediately around the lumpectomy site) Comparison of early and late stage toxicity after standard and hypofractioned courses Late effects include telangiectasia, breast shrinkage, and fibrosis How dose hypofractionation with a boost affect cosmesis?

16 Is tumor bed boost needed? Canada no boost UK and US generally includes tumor bed boost Especially for younger patients and patients with close margins 85% of American and 75% of European physicians deliver boost dose even with negative margins What is the optimal method? Still unanswered by hypofractionated protocols Concomitant boost of 50cGy/fx and sequential boost of 300cGy x 3fx proven effective Slight increase in acute and late skin toxicity

17 Can hypofractionation be used for patients with large breasts? Canada excludes patients with separation of over 25cm Vicini patients with large breast volumes (>1600cc) saw more acute skin toxicity Harsolia 59% of patients with large breast volumes (>1600cc) developed G2 and G3 skin reactions Ciammella significant correlation between acute skin toxicity and breast volume (P = )

18 Is there a way to deliver WB plus a boost while reducing hotspots? Technique suitable for all patients Technique that integrates boost, based on European trials and RTOG 1005 IMRT / VMAT could be that solution but we generally see an increase in low dose spray outside of the target region Could lead to secondary malignancies Breathing motion could be an issue What if we combine the best aspects of 3D and IMRT

19 Described by Charles Mayo as a technique that combines static and IMRT beams treated concurrently The prescribed dose is delivered via static fields and IMRT, with a split favoring the static fields more Separate prescriptions needed in treatment planning for static and IMRT beams, a Plan Sum can add the components together

20 Inverse optimization in Hybrid IMRT planning Can offer the potential of increased conformity Planner has ability to set constraints on PTVs and OARs during planning process Saved optimization guidelines can be used on whole subsets of patients to speed up the planning process Can reduce planning time Mayo suggests optimization time of mins Yields consistent results Can be useful for difficult anatomy Large separation, OAR in field, non uniform shape, etc.

21 Mayo (UMass): Compared wedged-field tangents, FIF, IMRT-only tangents, and 4 and 6 field hybrid plans 4-field hybrid conventional open field tangents plus 2 IMRT tangents Comparable to FIF in dosimetry, but significantly faster planning time 6-field hybrid conventional open field tangents plus 4 IMRT tangents 2 IMRT fields aligned with tangents, 2 anterior oblique IMRT fields Created the most conformal dose distribution, however low dose spray increased for surrounding normal tissue

22 Mayo (UMass): Mayo, et. al. Hybrid IMRT Plans-Concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time. IJROBP Pages

23 Mayo, et. al. Hybrid IMRT Plans-Concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time. IJROBP Pages

24 Asbury (University of Maryland): Static tangents in conjunction with IMRT beams using same beam angles as tangents IMRT beams were inversely optimized 2 separate Rx s for static and IMRT fields Benefits: Help achieve desired dose coverage and reduce hotspots in breast Suitable for patients that are more difficult to plan with tangential fields (ex wide separation, non-uniform shape, deep lumpectomy beds)

25

26 Technique: Use of static tangents and VMAT arcs to deliver a simultaneously integrated boost to the lumpectomy bed while delivering a uniform dose throughout the breast Potential benefits: Increased conformity Reduce hotspots Adaptable for all patients Ease of planning

27 Scheme Contouring Lots of contouring OARs GTVs CTVs PTVs Plan the tangents first Generate a VMAT plan Optimize with tangent plan as the Base Dose

28 Contouring GTV Lumpectomy excision cavity volume, clips, seroma CTVs Lumpectomy GTV + 1cm expansion, excludes 5mm skin contour, should not cross midline Breast apparent glandular tissue visualized on CT, exclude 5mm skin contour, follow RTOG Breast Atlas guidelines PTVs Lumpectomy CTV + 7mm expansion (excludes heart) Breast CTV + 7mm expansion PTV eval Lumpectomy PTV eval exclude part outside of breast, exclude 5mm skin contour Breast PTV eval exclude 5mm skin contour, posteriorly no deeper than anterior surface of ribs For DVH analysis only OARs: Heart Lungs (ipsilateral and contralateral) Contralateral breast Thyroid

29 Planning the Tangents Determine optimal beam angles Avoid entry/exit into contralateral breast Shape MLCs 5mm aperture for the breast PTV Add 2cm or more for flash Determine beam energy Depending on anatomy and separation Can incorporate high energy photons into tangents Plan with only 6MV for VMAT

30 Planning the Tangents Determining the appropriate weight of the tangents A good starting point is to have 2400cGy (60% WB dose) adequately cover the breast PTV eval Can use plan normalization to cover the breast PTV eval with adequate dose If plan sum with VMAT is subpar, one can increase weight of tangential plan

31 VMAT Planning Use of 2 Arcs Increase conformity and yield more homogenous dose within breast PTV Arc angles went from one tangent angle to the other Base Dose Planning Use tangent plan as base dose Allows VMAT to fill in the cracks Enables coverage of Breast PTV and simultaneously boosts Lumpectomy PTV

32 Slappa da bass, mon!

33 Varian Eclipse Can optimize an IMRT or VMAT plan from an existing dose Can be another plan or same plan Plan can be 3D, IMRT, or VMAT Can be employed in either DVO or PRO algorithms Precalculated dose distributions taken into account during optimization process Fill in gaps from previous plan in plan sum Improve homogeneity in tumor volumes Improve conformity

34

35 VMAT Optimization Set PTV and OAR goals Helper contours Breast-Lumpectomy Helps increase homogeneity in breast and enable lumpectomy simultaneously-integrated boost Interactive optimization Helpful in determining ability to meet constraints Allows one to optimize on fly Can change constraints during optimization

36 Delivery Integrated boost will require separate plan to be moded up at treatment machine Delivery time for tangents should be similar between FiF and static fields Arc delivery should also be comparable to boost fields Delivery time for 2 or 3 boost fields with wedges or EDW would be similar to 2 partial arcs

37 Other Caveats QA IMRT QA would be required for VMAT fields Increase in workload for physicists, unless they are already performing QA for FiF plans QA device for VMAT would be needed ArcCheck, EPID, Matrixx RMM Decisions regarding RMM would need to be made Monitor each patient If 4DCT is available, it could be helpful to determine amount of motion Consider on a patient-by-patient basis

38 Ideal Breast PTV eval D 95 95% WB Rx Dose (3800cGy) D 30 Lump Rx Dose (4800cGy) D % WB Rx Dose (4320cGy) Lumpectomy PTV eval D 95 95% Lump Rx Dose (4560cGy) D 5 110% Lump Rx Dose (5280cGy) D max 115% Lump Rx Dose (5520cGy) Acceptable Breast PTV eval D 90 90% WB Rx Dose (3600cGy) D 35 Lump Rx Dose (4800cGy) D % WB Rx Dose (4480cGy) Lumpectomy PTV eval D 95 90% Lump Rx Dose (4320cGy) D % Lump Rx Dose (5280cGy) D max 120% Lump Rx Dose (5520cGy)

39 Ideal Heart left D 5 < 1600cGy D 30 < 800cGy Mean < 320cGy Heart - right D max < 1600cGy D 10 < 800cGy Mean < 320cGy Acceptable Heart left D 5 < 2000cGy D 35 < 800cGy Mean < 400cGy Heart - right D max < 2000cGy D 15 < 800cGy Mean < 400cGy

40 Ideal Ipsilateral Lung D 15 < 1600cGy D 35 < 800cGy D 50 < 400cGy Contralateral Lung D 10 < 400cGy Acceptable Ipsilateral Lung D 20 < 1600cGy D 40 < 800cGy D 55 < 400cGy Contralateral Lung D 15 < 400cGy

41 Ideal Contralateral Breast D max < 240cGy D 5 < 144cGy Thyroid D max < 96cGy Acceptable Contralateral Breast D max < 384cGy D 5 < 240cGy Thyroid D max < 144cGy

42 Retrospective study 9 patients previously treated with FiF+3D boost 5 Left, 4 Right PTV eval volume ranged from 448cc to 1560cc (average = 938cc) Played by the RTOG 1005 rules MLC shaping for tangents PTV coverage OAR sparing All Hybrid-VMAT plans planned with set of tangents and 2 partial arcs 6X and 18X used on tangents 6X used for ARCs

43

44 Ideal Acceptable Total Structure Volume Goal Volume Goal Hybrid FiF+3D > 95% 3800 > 90% Breast < 30% 4800 < 35% PTVeval < 50% 4320 < 50% CI95.95 to 2.0 CI95.85 to Lumpectomy PTVeval Heart (Left) Heart (Right) Ipsilateral Lung > 95% 4560 > 95% < 5% 5280 < 10% max pt dose 5520 max pt dose CI95.95 to 2.5 CI95.9 to < 5% 1600 < 5% <30% 800 <35% mean 320 mean % % <10% 800 <15% mean 320 mean < 15% 1600 < 20% < 35% 800 < 40% < 50% 400 < 55% Contralateral Lung < 10% 400 < 15% Contralateral dmax 240 dmax Breast < 5% 144 < 5% Thyroid dmax 96 dmax

45 Ideal Acceptable Total Structure Volume Goal Volume Goal Hybrid FiF+3D > 95% 3800 > 90% Breast < 30% 4800 < 35% PTVeval < 50% 4320 < 50% CI95.95 to 2.0 CI95.85 to Lumpectomy PTVeval > 95% 4560 > 95% < 5% 5280 < 10% max pt dose 5520 max pt dose CI95.95 to 2.5 CI95.9 to

46 Ideal Acceptable Total Structure Volume Goal Volume Goal Hybrid FiF+3D < 5% 1600 < 5% Heart (Left) <30% 800 <35% mean 320 mean % % Heart (Right) <10% 800 <15% mean 320 mean < 15% 1600 < 20% Ipsilateral Lung < 35% 800 < 40% < 50% 400 < 55% Contralateral Lung < 10% 400 < 15% Contralateral Breast dmax 240 dmax < 5% 144 < 5% Thyroid dmax 96 dmax

47

48

49 Hybrid FiF + 3D

50

51

52

53 Hybrid FiF + 3D

54 Hybrid FiF+3D

55

56

57

58

59

60

61

62

63

64

65 Hybrid-VMAT improves: Conformity! CI 95 for both the breast and lumpectomy PTV eval volumes dropped considerably with this approach Less normal tissue receiving high dose and less breast tissue receiving boost dose Lumpectomy CI 95 dropped from 2.27 to 1.54 with hybrid VMAT Breast CI 95 dropped from 1.49 to 1.22 with hybrid VMAT

66 Hybrid-VMAT improves: Planning time Inverse optimization allows for one to import pre-set goals for dose-volumes and weighting Simply loading optimization gets process rolling quickly No setting up FiF simply set tangents, select energy and weight beams to your liking No determining best 3D boost approach, boost taken care of during VMAT optimization More experience less planning time and better results

67 Hybrid-VMAT drawbacks: Low dose spray What is acceptable? See higher volumes of lung and heart receiving more low dose Plans met acceptable DVH goals at the minimum, set by RTOG Possible increase in secondary cancer risk due to low dose spray associated with VMAT RMM issues Insurance coverage Plan is more complex to deliver

68 Free breathing What about FLASH? Can create a flash structure to optimize to Respiratory Motion Management Can perform respiratory gating Minimize variation of breast motion via DIBH and ABC Tsai, et. al. - could cut up arcs into smaller arcs to deliver during a breathhold to control motion Can monitor breathing motion from 4D CT scan to determine magnitude of motion

69 Introduction of VMAT beams could increase risk of secondary cancers More low dose spray associated with VMAT than tangential beam delivery More beam on time increase in head leakage and collimator scatter Abo-Madyan, et. al. reported secondary cancer risk after 3D or FiF delivery for breast cancer was about 34% lower than IMRT or VMAT using linear modeling About 50% lower when using linear-exponential model

70 Hypofractionation has a future in radiation therapy for breast cancer in the US Still no best practice for lumpectomy boost when delivering hypofractionation No boost, cone down, or SIB? Hybrid planning can yield very conformal plans that meet clinical tolerances Could be a useful tool in treating WB + SIB in the future

71 VU Softball Champs 2011

72 Phase I and II Studies safety and efficacy Freedman 2007 WB 225cGy x 20 (4500cGy), SIB 280cGy x 20 (5600cGy) IMRT acceptable treatment modality No grade 3 skin toxicity, all grade 2 and lower resolved in 6 weeks post treatment 5 year local recurrence was 1.4% Chadha cgy to whole breast in 15 fx 4500cGy to boost volume concomitantly Conventional whole breast irradiation No grade 3 toxicities

73 Phase I and II Studies safety and efficacy Formenti cGy to whole breast in 15 fx 4800cGy to boost volume concomitantly IMRT acceptable treatment modality Grade 1-2 dermatitis in 67% of patients 2 Grade 3 toxicites 1 skin, 1 fatigue Breast pain grade 1 8%, grade 2 2% 1 regional node recurrence

74 3 Phase I and II Studies safety and efficacy Ciamella Italy patients on trial T1-T2, N0-N1 267cGy x 15 + possible boost Boost of 300cGy x 3 for patients with high risk factors (age < 50, close margins) Cosmesis good or excellent in 92% of patients Acute skin toxicity of G1 (79%), G2 (12%), G3 (1 patient) Late skin toxicity of G1 or G2 in <20%, no G3, corresponded with boost delivery

75 Compared to IMRT plans, Hybrid plans for lung and esophageal patients were seen to reduce lung dose (V20, V13, and V5) Hybrid planning also reduced potential magnitude of motion-induced dose distribution deviations

76

Clinical experience with TomoDirect System Tangential Mode

Clinical experience with TomoDirect System Tangential Mode Breast Cancer Clinical experience with TomoDirect System Tangential Mode European Institute of Oncology Milan, Italy Disclosure & Disclaimer An honorarium is provided by Accuray for this presentation The

More information

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer Tony Kin Ming Lam Radiation Planner Dr Patricia Lindsay, Radiation Physicist Dr John Kim, Radiation Oncologist Dr Kim Ann Ung,

More information

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413 NSABP PROTOCOL B-39B RTOG PROTOCOL 0413 (A RANDOMIZED PHASE III STUDY OF CONVENTIONAL WHOLE BREAST IRRADIATION WBI) VERSUS PARTIAL BREAST IRRADIATION (PBI) FOR WOMEN WITH STAGE 0, I, OR II BREAST CANCER

More information

Partial Breast Irradiation using adaptive MRgRT

Partial Breast Irradiation using adaptive MRgRT Partial Breast Irradiation using adaptive MRgRT Shyama Tetar, radiation-oncologist VUmc Amsterdam 15-12-2017 5 th Vumc SBRT symposium 2017 Current practice Breast conserving treatment (BCT) Breast conserving

More information

Post-Lumpectomy Radiation Techniques and Toxicities

Post-Lumpectomy Radiation Techniques and Toxicities Post-Lumpectomy Radiation Techniques and Toxicities Laura Willson, MD Abbott Northwestern Hospital Dept. of Radiation Oncology February 2, 2019 Learning Objectives How radiation therapy works Standard

More information

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures***

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** Review the clinical targets for breast RT as a function of cancer stage Learn about innovative

More information

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10 Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10 Simon Goodall Radiation Oncology Physicist Genesis Care Western Australia Introduction

More information

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population A Dosimetric Comparison of Whole-Lung Treatment Techniques in the Pediatric Population Corresponding Author: Christina L. Bosarge, B.S., R.T. (R) (T) Indiana University School of Medicine Department of

More information

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse Peters et al. Radiation Oncology 2014, 9:153 RESEARCH Open Access A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse Samuel Peters

More information

PRONE BREAST WHAT S THE BIG DEAL? Rachel A. Hackett CMD, RTT

PRONE BREAST WHAT S THE BIG DEAL? Rachel A. Hackett CMD, RTT PRONE BREAST WHAT S THE BIG DEAL? Rachel A. Hackett CMD, RTT BREAST CANCER TREATMENT OPTIONS Surgical Options For the breast: Breast conserving surgery (lumpectomy) Breast Conservation Therapy = surgery

More information

The Physics of Oesophageal Cancer Radiotherapy

The Physics of Oesophageal Cancer Radiotherapy The Physics of Oesophageal Cancer Radiotherapy Dr. Philip Wai Radiotherapy Physics Royal Marsden Hospital 1 Contents Brief clinical introduction Imaging and Target definition Dose prescription & patient

More information

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia IMRT - the physician s eye-view Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia The goals of cancer therapy Local control Survival Functional status Quality of life Causes

More information

IMRT Planning Basics AAMD Student Webinar

IMRT Planning Basics AAMD Student Webinar IMRT Planning Basics AAMD Student Webinar March 12, 2014 Karen Chin Snyder, MS Senior Associate Physicist Department of Radiation Oncology Disclosures The presenter has received speaker honoraria from

More information

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida American Association of Medical Dosimetrists 2015 Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida Most

More information

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO Investigations and research Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO M. Kunze-Busch P. van Kollenburg Department of Radiation Oncology, Radboud University Nijmegen Medical

More information

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T) Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer Scott Boulet BSc, RT(T) Outline Background Objectives Design Results Discussion Conclusion Acknowledgements Questions Background

More information

Protocol of Radiotherapy for Breast Cancer

Protocol of Radiotherapy for Breast Cancer 107 年 12 月修訂 Protocol of Radiotherapy for Breast Cancer Indication of radiotherapy Indications for Post-Mastectomy Radiotherapy (1) Axillary lymph node 4 positive (2) Axillary lymph node 1-3 positive:

More information

Additional Questions for Review 2D & 3D

Additional Questions for Review 2D & 3D Additional Questions for Review 2D & 3D 1. For a 4-field box technique, which of the following will deliver the lowest dose to the femoral heads? a. 100 SSD, equal dmax dose to all fields b. 100 SSD, equal

More information

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS ICTP SCHOOL ON MEDICAL PHYSICS FOR RADIATION THERAPY DOSIMETRY AND TREATMENT PLANNING FOR BASIC AND ADVANCED APPLICATIONS March

More information

Recent Advances in Breast Radiotherapy

Recent Advances in Breast Radiotherapy Recent Advances in Breast Radiotherapy Dr Anna Kirby Consultant Clinical Oncologist 2 The Royal Marsden Overview: Key innovations 1. 2D to 3D planning 2. Hypofractionation 3. Intensity modulated radiotherapy

More information

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD Dosimetry Planning CPT Codes: 77295, 77300, 77301, 77306, 77307, 77321, 77316, 77317, 77318, 77331, 77399 Original Date: April, 2011 Last Reviewed

More information

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook

More information

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,

More information

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer 1 Charles Poole April Case Study April 30, 2012 Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer Abstract: Introduction: This study

More information

Treatment Planning for Breast Cancer: Contouring Targets. Julia White MD Professor

Treatment Planning for Breast Cancer: Contouring Targets. Julia White MD Professor Treatment Planning for Breast Cancer: Contouring Targets Julia White MD Professor Outline 1. RTOG Breast Cancer Atlas 2. Target development on Clinical Trials Whole Breast Irradiation 2-D Radiotherapy

More information

Chapters from Clinical Oncology

Chapters from Clinical Oncology Chapters from Clinical Oncology Lecture notes University of Szeged Faculty of Medicine Department of Oncotherapy 2012. 1 RADIOTHERAPY Technical aspects Dr. Elemér Szil Introduction There are three possibilities

More information

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize

More information

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation 2017 AAMD 42 nd Annual Meeting Neil C. Estabrook, MD 6 / 14 / 2017 7/5/2017 1 Conflicts of Interest None

More information

Evaluation of three APBI techniques under NSABP B-39 guidelines

Evaluation of three APBI techniques under NSABP B-39 guidelines JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 1, WINTER 2010 Evaluation of three APBI techniques under NSABP B-39 guidelines Daniel Scanderbeg, a Catheryn Yashar, Greg White, Roger Rice,

More information

Fiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach

Fiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach Fiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach Jesse McKay, MS, DABR Erlanger Health System Chattanooga, TN JASTRO 2014, Yokohama Japan Disclosure I have

More information

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments Radiation Damage Comparison between Intensity Modulated Radiotherapy () and Field-in-field (FIF) Technique In Breast Cancer Treatments Huisi Ai 1 and Hualin Zhang 2 1. Department of Radiation Oncology,

More information

Implementation of Hybrid IMRT Breast Planning

Implementation of Hybrid IMRT Breast Planning Implementation of Hybrid IMRT Breast Planning Dianne Kearns, Richard Ferguson & Suzanne Smith Dosimetrist Manager Department of Clinical Physics and Bio-Engineering, NHS Greater Glasgow & Clyde Summary

More information

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T) SBRT TREATMENT PLANNING: TIPS + TRICKS Rachel A. Hackett CMD, RT(T) OUTLINE Brief radiobiology review 3D CRT Tx Planning VMAT Tx Planning Protocols Other Sites Oligomets Spine Liver Kidney Adrenal Gland

More information

3D-CRT Breast Cancer Planning

3D-CRT Breast Cancer Planning 3D-CRT Breast Cancer Planning Tips and Tricks Bednář, V. 3D-CRT Obsolete or not? There are more advanced techniques than 3D-CRT, but 3D-CRT has some advantages: Availability and price Forward planning

More information

Radiation Therapy: From Fallacy to Science

Radiation Therapy: From Fallacy to Science 27 th Annual Management of Colon and Rectal Diseases 2.23.2019 Radiation Therapy: From Fallacy to Science Hadi Zahra, MD, DABR Radiation Oncologist CHI Health Henry Lynch Cancer Center Assistant Clinical

More information

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction 1 The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Megan E. Sullivan, B.S., R.T.(T)., Patrick A. Melby, B.S. Ashley Hunzeker, M.S., CMD, Nishele Lenards, M.S., CMD, R.T. (R)(T),

More information

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction 1 The Effects of DIBH on Liver Dose during Right-Breast Treatments Megan E. Sullivan B.S.R.T.(T)., Patrick A. Melby, B.S. Ashley Hunzeker, M.S., CMD, Nishele Lenards, M.S., CMD Medical Dosimetry Program

More information

SIMPLE IMPLEMENTATION OF A DIBH TANGENTIAL IMRT TECHNIQUE FOR LEFT-SIDED BREAST CANCER

SIMPLE IMPLEMENTATION OF A DIBH TANGENTIAL IMRT TECHNIQUE FOR LEFT-SIDED BREAST CANCER SIMPLE IMPLEMENTATION OF A DIBH TANGENTIAL IMRT TECHNIQUE FOR LEFT-SIDED BREAST CANCER Dominique Mathieu MD MSc, Nicolas Côté MSc, Andrée-Anne Bernard MD, Noémie Lahaie RTT, Stéphane Bedwani PhD, Jean-François

More information

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD Barbara Agrimson, BS RT(T)(R), CMD Disclaimer This presentation will mention equipment by trade name.

More information

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

The role of Radiation Oncologist: Hi-tech treatments for liver metastases The role of Radiation Oncologist: Hi-tech treatments for liver metastases Icro Meattini, MD Radiotherapy-Oncology Unit AOU Careggi Hospital Florence University, Italy Liver Metastases - Background The

More information

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session Stereotactic Body Radiation Therapy Quality Assurance Educational Session J Perks PhD, UC Davis Medical Center, Sacramento CA SBRT fundamentals Extra-cranial treatments Single or small number (2-5) of

More information

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT Purpose The purpose of this curriculum outline is to provide a framework for multidisciplinary training for radiation oncologists, medical

More information

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast 1 Angela Kempen February Case Study February 22, 2012 3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast History of Present Illness: JE is a 45 year-old Caucasian female who underwent

More information

New Technologies in Radiation Oncology. Catherine Park, MD, MPH Advocate Good Shepherd Hospital

New Technologies in Radiation Oncology. Catherine Park, MD, MPH Advocate Good Shepherd Hospital New Technologies in Radiation Oncology Catherine Park, MD, MPH Advocate Good Shepherd Hospital Breast Radiation Early Stage Breast Cancer Whole Breast Radiation Delivered to the whole breast Boost to the

More information

Is there a preferred IMRT technique for left-breast irradiation?

Is there a preferred IMRT technique for left-breast irradiation? JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 3, 2015 Is there a preferred IMRT technique for left-breast irradiation? Marloes Jeulink, a Max Dahele, Philip Meijnen, Ben J. Slotman, Wilko

More information

ASTRO econtouring for Lymphoma. Stephanie Terezakis, MD

ASTRO econtouring for Lymphoma. Stephanie Terezakis, MD ASTRO econtouring for Lymphoma Stephanie Terezakis, MD Disclosures No conflicts to disclose 1970 Total Lymphoid Irradiation (TLI) 1995 Involved-Field Radiotherapy (IFRT) 2008 Involved Node Radiotherapy

More information

8/3/2016. Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patients. Acknowledgement. Overview

8/3/2016. Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patients. Acknowledgement. Overview Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patients Liyong Lin, PhD, Assistant Professor Department of Radiation Oncology University of Pennsylvania Acknowledgement

More information

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem Original Article Treatment Planning Evaluation of Sliding Window and Multiple Static Segments Technique in Intensity Modulated Radiotherapy for Different Beam Directions Teyyiba Kanwal, Muhammad Khalid,

More information

Prone Breast, Pre- Surgery. A case study; The OSU Way.

Prone Breast, Pre- Surgery. A case study; The OSU Way. Prone Breast, Pre- Surgery. A case study; The OSU Way. Karla Kuhn, CMD, RT(R)(T) Lee Culp, M.S. CMD, RT(T) June 2017 The Ohio State University Comprehensive Cancer Center Arthur G. James Cancer Hospital

More information

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 Lung Spine Phantom Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 The study groups are requesting that each institution keep the phantom for no more than 2 week. During this

More information

Electron Beam ET - Reloaded Therapy - Reloaded

Electron Beam ET - Reloaded Therapy - Reloaded 8/4/216 Electron Beam ET - Reloaded Therapy - Reloaded Qiuwen Wu, Ph.D. Department of Radiation Oncology Duke University 1 Introduction: e vs. γ vs. p Electron Photon Proton Depth dose and lateral profiles

More information

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016 TomoTherapy Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA May 2016 TomoTherapy The Facts Greek Tomo = slice Advanced form of IMRT 3D computerised tomography (CT) imaging immediately prior

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy Intensity Modulated Radiation Therapy (IMRT) of Head and Neck File Name: Origination: Last CAP Review: Next CAP Review: Last Review: intensity_modulated_radiation_therapy_imrt_of_head_and_neck

More information

Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation

Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 3, 2015 Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation Harumitsu Hashimoto, 1,3a Motoko Omura,

More information

San Antonio Breast Cancer Symposium 2010 Highlights Radiotherapy

San Antonio Breast Cancer Symposium 2010 Highlights Radiotherapy San Antonio Breast Cancer Symposium 2010 Highlights Radiotherapy Kathleen C. Horst, M.D. Assistant Professor Department of Radiation Oncology Stanford University The Optimal SEquencing of Adjuvant Chemotherapy

More information

Overview of Advanced Techniques in Radiation Therapy

Overview of Advanced Techniques in Radiation Therapy Overview of Advanced Techniques in Radiation Therapy Jacob (Jake) Van Dyk Manager, Physics & Engineering, LRCP Professor, UWO University of Western Ontario Acknowledgements Glenn Bauman Jerry Battista

More information

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER Romanian Reports in Physics, Vol. 67, No. 3, P. 978 986, 2015 VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER D. ADAM 1, 2, M.D. SUDITU 1, 2, R. POPA 1, 2, V. CIOCALTEI

More information

Normal tissue dose in pediatric VMAT Piotr Zygmanski

Normal tissue dose in pediatric VMAT Piotr Zygmanski Normal tissue dose in pediatric VMAT Piotr Zygmanski Department of Radiation Oncology Brigham and Women s Hospital Radiation induced effects in children Risk of inducing 2 nd cancers higher than for adults

More information

Radiation Therapy for breast with Tomotherapy: When?

Radiation Therapy for breast with Tomotherapy: When? Radiation Therapy for breast with Tomotherapy: When? Roberto Orecchia Chair of Radiation Therapy at the University of Milan, IEO & CNAO Quarto incontro italo-francese sul carcinoma mammario: Problematiche

More information

Savita Dandapani, MD, PhD City of Hope Duarte, CA

Savita Dandapani, MD, PhD City of Hope Duarte, CA Savita Dandapani, MD, PhD City of Hope Duarte, CA Financial Disclosures Accuray Funding Outline TomoTherapy at City of Hope: TBI TMI Recent experience at City of Hope with TomoDirect : TomoDirect for Lower

More information

Leila E. A. Nichol Royal Surrey County Hospital

Leila E. A. Nichol Royal Surrey County Hospital 2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry

More information

Implementation of advanced RT Techniques

Implementation of advanced RT Techniques Implementation of advanced RT Techniques Tibor Major, PhD National Institute of Oncology Budapest, Hungary 2. Kongres radiološke tehnologije, Vukovar, 23-25. September 2016. Current RT equipments at NIO,

More information

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY doi:10.1016/j.ijrobp.2009.03.029 Int. J. Radiation Oncology Biol. Phys., Vol. 75, No. 1, pp. 253 259, 2009 Copyright Ó 2009 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/09/$ see front

More information

Intensity Modulated Radiotherapy (IMRT) of the Thorax

Intensity Modulated Radiotherapy (IMRT) of the Thorax Medical Policy Manual Medicine, Policy No. 136 Intensity Modulated Radiotherapy (IMRT) of the Thorax Next Review: August 2018 Last Review: November 2017 Effective: December 1, 2017 IMPORTANT REMINDER Medical

More information

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study imedpub Journals http://www.imedpub.com Archives Archives in Cancer in Cancer Research Research ISSN 2254-681 Abstract Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast

More information

Treatment Planning & IGRT Credentialing for NRG SBRT Trials

Treatment Planning & IGRT Credentialing for NRG SBRT Trials Treatment Planning & IGRT Credentialing for NRG SBRT Trials Hania Al Hallaq, Ph.D. Department of Radiation & Cellular Oncology The University of Chicago Learning Objectives Explain rationale behind credentialing

More information

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI

More information

Hypofractionated Radiotherapy for breast cancer: Updated evidence

Hypofractionated Radiotherapy for breast cancer: Updated evidence 2 rd Bangladesh Breast Cancer Conference, Dhaka, December 2017 Hypofractionated Radiotherapy for breast cancer: Updated evidence Tabassum Wadasadawala Associate Professor of Radiation Oncology Tata Memorial

More information

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D. Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, 2014 Pamela Myers, Ph.D. Introduction o o o o o Outline GRID compensator Purpose of SFRT/GRID therapy Fractionation

More information

COMPARISON OF THREE CONCOMITANT BOOST TECHNIQUES FOR EARLY-STAGE BREAST CANCER

COMPARISON OF THREE CONCOMITANT BOOST TECHNIQUES FOR EARLY-STAGE BREAST CANCER doi:10.1016/j.ijrobp.2005.07.004 Int. J. Radiation Oncology Biol. Phys., Vol. 64, No. 1, pp. 168 175, 2006 Copyright 2006 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/06/$ see front

More information

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n.

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n. University of Groningen Optimising CT guided radiotherapy for breast cancer Laan, Hans Paul van der IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite

More information

Advances in external beam radiotherapy

Advances in external beam radiotherapy International Conference on Modern Radiotherapy: Advances and Challenges in Radiation Protection of Patients Advances in external beam radiotherapy New techniques, new benefits and new risks Michael Brada

More information

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer Tan Chek Wee 15 06 2016 National University Cancer Institute, Singapore Clinical Care Education Research

More information

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 IROC Liver Phantom Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 The study groups are requests that each institution keep the phantom for no more than 2 weeks. During

More information

Many vendors are beginning to allow couch motion during radiation delivery.

Many vendors are beginning to allow couch motion during radiation delivery. Dynamic Couch Motion Many vendors are beginning to allow couch motion during radiation delivery. Varian developer mode allows institutions to perform research using these types of treatments. Tomotherapy

More information

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology Treatment Planning for Lung Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology Outline of Presentation Dosimetric planning strategies for SBRT lung Delivery techniques Examples

More information

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy 1 Donovan EM, 1 Brooks C, 1 Mitchell A, 2 Mukesh M, 2 Coles CE, 3 Evans PM, 1 Harris EJ 1 Joint Department of Physics, The Royal Marsden/Institute

More information

Follow this and additional works at:

Follow this and additional works at: The University of Toledo The University of Toledo Digital Repository Theses and Dissertations 2015 Comparison of radiation treatment plans for breast cancer between 3D conformal in prone and supine positions

More information

Mesothelioma XRT: From Old School to New School. A brief walk down memory lane at UCLA

Mesothelioma XRT: From Old School to New School. A brief walk down memory lane at UCLA Mesothelioma XRT: From Old School to New School A brief walk down memory lane at UCLA Sherri Alexander, RTT CMD Thanks Michael Selch MD Percy Lee MD Amar Kishan MD Sharon Qi, Phd Julie Kang, MD Objectives

More information

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University Content 1.Introduction 2.Methods and materials 3.Results and discussion 4.Conclusion

More information

RTTs role in lung SABR

RTTs role in lung SABR RTTs role in lung SABR Bart van Baaren Lineke van der Weide VU Medical Centre SBRT symposium VUMC 16 December 2017 Flow chart lung SABR Pre-treatment imaging Treatment planning On-line imaging Treatment

More information

Beam Direction RAO LAO. Pt supine. LL Treatment couch LPO RPO. WHA Consulting. Wilson Apollo

Beam Direction RAO LAO. Pt supine. LL Treatment couch LPO RPO. WHA Consulting. Wilson Apollo Beam Direction AP RAO LAO Pt supine RL LL Treatment couch RPO LPO PA Wilson Apollo DELIVERY TECHNOLOGY & CODING Based on FORDS Manual Equipment Dose Delivery Method Modality Code Comments Zeiss Intrabeam

More information

Breast Conservation Therapy

Breast Conservation Therapy May 18, 2018 Breast Conservation Therapy One Treatment No Longer Fits All Presenter: Paul B. Fowler, MD Radiation Oncology, MGSH/MUMH 1 Objectives: 1. Define stages of breast cancer that are candidates

More information

PEDIATRIC ORBITAL TUMORS RADIOTHERAPY PLANNING

PEDIATRIC ORBITAL TUMORS RADIOTHERAPY PLANNING PEDIATRIC ORBITAL TUMORS RADIOTHERAPY PLANNING ANATOMY ANATOMY CONT ANATOMY CONT. ANATOMY CONT. EYE OF A CHILD Normal tissue tolerance doses (in conventional #) TD 5/5 TD 50/5 Endpoint Gy Gy Optic nerve

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy Intensity Modulated Radiation Therapy (IMRT) of the Chest File Name: Origination: Last CAP Review: Next CAP Review: Last Review: intensity_modulated_radiation_therapy_imrt_of_the_chest

More information

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical sites. The final aim will be to be able to make out these

More information

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy Guidelines for Planning and Irradiating the RPC Liver Phantom. Revised Dec 2005 Credentialing for this protocol requires four steps:

More information

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas 1 Carol Boyd Comprehensive Case Study July 11, 2013 Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas Abstract: Introduction:

More information

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015 IROC Lung Phantom 3D CRT / IMRT Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015 The IROC requests that each institution keep the phantom for no more than 2 weeks. During

More information

GUIDELINES FOR RADIOTHERAPY IN EARLY BREAST CANCER

GUIDELINES FOR RADIOTHERAPY IN EARLY BREAST CANCER GUIDELINES FOR RADIOTHERAPY IN EARLY BREAST CANCER Authors: Dr N Thorp/ Dr P Robson On behalf of the Breast CNG Written: Originally - December 2008 Reviewed: Updated - December 2011 Agreed: Breast TSG

More information

IMAT: intensity-modulated arc therapy

IMAT: intensity-modulated arc therapy : intensity-modulated arc therapy M. Iori S. Maria Nuova Hospital, Medical Physics Department Reggio Emilia, Italy 1 Topics of the talk Rotational IMRT techniques: modalities & dedicated inverse-planning

More information

La Pianificazione e I Volumi di Trattamento

La Pianificazione e I Volumi di Trattamento TRATTAMENTI INTEGRATI NEL CARCINOMA DELLA VULVA La Pianificazione e I Volumi di Trattamento PAOLO MUTO Direttore UOC Radioterapia ISTITUTO NAZIONALE TUMORI IRCCS Fondazione Pascale di Napoli Minimize collateral

More information

Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed

Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed Take home message Preliminary data shows CRT technique in NSCLC allows dose escalation to an unprecedented level maintaining cancer

More information

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT) Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT) James Kavanaugh, MS DABR Department of Radiation Oncology Division of Medical Physics Outline Importance

More information

Image Guided Stereotactic Radiotherapy of the Lung

Image Guided Stereotactic Radiotherapy of the Lung Image Guided Stereotactic Radiotherapy of the Lung Jamie Marie Harris, MS DABR Avera McKennan Radiation Oncology September 25, 2015 Stereotactic Body Radiotherapy - Clinical Dose/Fractionation - Normal

More information

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018 It s All About Margins Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018 Why margins? The smaller the better! Short Introduction Erasmus MC has been using the CyberKnife Robotic Radiosurgery System

More information

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist Automated Plan Quality Check with Scripting Rajesh Gutti, Ph.D. Clinical Medical Physicist Veera.Gutti@BSWHealth.org Outline Introduction - BSW Automation in Treatment planning Eclipse Scripting API Script

More information

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington Sarcoma and Radiation Therapy Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington Objective: Helping you make informed decisions Introduction Process Radiation

More information

RADIOTHERAPY IN BREAST CANCER :

RADIOTHERAPY IN BREAST CANCER : RADIOTHERAPY IN BREAST CANCER : PAST, PRESENT, FUTURE Dr Jyotirup Goswami Consultant Radiation Oncologist Narayana Cancer Institute Narayana Superspecialty Hospital Breast cancer is the classic paradigm

More information

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain 1 Carol Boyd March Case Study March 11, 2013 Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain History of Present Illness:

More information