Time-optimization of a chromatographic method for monitoring a multistep enzymatic conversion of epoxides to 1,2-diols

Size: px
Start display at page:

Download "Time-optimization of a chromatographic method for monitoring a multistep enzymatic conversion of epoxides to 1,2-diols"

Transcription

1 MAHA NAIM Time-optimization of a chromatographic method for monitoring a multistep enzymatic conversion of epoxides to 1,2-diols Thesis Bachelor of Science in Chemistry March 2014 Bachelor Degree project in Chemistry (15 hp) Department of Chemistry BMC Supervisor: Mikael Widersten and Åsa Janfalk Carlsson

2 Abstract The enzymatic conversion of selected epoxides into diols and ketones was monitored by time optimized reversed phase chromatography. Reaction samples were first analyzed isocratically to identify the components of different peaks. In the next step the samples were run with a gradient elution to shorten the retention time between the compounds in the multistep reaction with retained separation of a good quality. The use of a mm reversed phase C-18 column with an optimized water and acetonitrile gradient allowed an analysis time of the compounds in the multistep reaction could be optimized to 20 min, with good resolution. This result represents an improvement compared to earlier protocols that required 45 min and 74 min respectively. Svensk sammanfattning Den enzymatiska omvandlingen av utvalda epoxider till dioler och ketoner övervakades med en tidsoptimerad reversed phase kromatografi. Reaktionsprover analyserades först sokratiskt för att identifiera föreningarna med olika toppar. I nästa steg analyserades proverna med en gradienteluering för att kunna förkorta analystiden mellan föreningarna i multistegsreaktionen med bibehållen god separation Användningen av en mm reversed phase C-18-kolonn med optimerad vatten- och acetonitrilgradient tillät att analystiden av föreningarna i multistegsreaktionen kunde optimeras till 20 min med en god upplösning. Detta resultat är en förbättring jämfört med tidigare protokoll som krävde 45 respektive 74 min. 2

3 List of abbreviations AdhA Rhodococcus ruber alcohol dehydrogenase A Diol 1 Diol 2 2,3-EPB HPLC Ketone 1 ketone 2 NAD + PDA SO StEH1 1-phenyl-1,2-ethanediol 3-phenyl-1,2-propanediol 2,3-epoxyprobylbenzene high performance liquid chromatography 2-hydroxyacetophenone 1-hydroxy-3-phenylpropan-2-one nicotinamide adenine dinucleotide photodiode array detector styrene oxide Solanum tuberosum epoxide hydrolase 1a 3

4 Table of contents Abstract...2 Svensk sammanfattning...2 List of abbreviations...3 Table of contents...4 Introduction...5 Aim of the project...5 Materials and Methods...7 Equipment...7 Chemicals and materials...7 Sample preparation...7 Gradient experiment...8 The substrates...9 Results The isocratic separation of SO, 2,3-EPB and the reaction products of SO Shortening of the analysis time by gradient elution Discussion Conclusion Personal reflection Acknowledgements References Appendix

5 Introduction Aim of the project The main aim of the project was to develop a time optimized analysis of the compounds in the multistep reaction (Figure 1). The research project was first run by Professor Mikael Widersten and his coworkers to study enzymatic conversion of epoxides, using a multistep enzyme approach. As a starting point, selected epoxides are hydrolyzed by the enzyme epoxide hydrolase 1a from Solanum tuberosum (StEH1) to form the corresponding diols. These diols are further converted into ketones by alcohol dehydrogenase A from Rhodococcus ruber (AdhA), (Figure 1). StEH1 H 2O AdhA NAD + Figure 1- Styrene oxide is hydrolyzed by the enzyme StEH1 to form a diol. The diol is then converted into a ketone by alcohol dehydrogenase AdhA. The epoxides used here are styrene oxide (SO) and 2,3-epoxypropylbenzene (2,3-EPB). The hydrolysis of 2,3-EPB cannot be measured by spectrophotometer due to similar absorbance spectra for the epoxide and the diol. As a Consequence HPLC was used to monitor the reaction shown in figure 1. In early protocol based on reversed phase chromatography each sample required 80 minutes. Thus, it is desirable to reduce the analysis time. The actual separation principle used here was a reversed phase chromatography that employs a nonpolar stationary phase, in this case a short C-18 column was used. The C-18 name refers to a stationary phase based on microporous silica particles that are derivatized with 18- carbon hydrocarbon chains. The requirement was to maintain a sufficiently good resolution, which 5

6 means not only to obtain as short analysis time as possible, but also to get a good separation between the compounds. The packed column efficiency increases as the particles size of the stationary phase decreases. The experimental factors that could influence the resolution were the flow rate, gradient elution and the column height. The resolution is often described by the plate number (N) which corresponds to the number of discrete distributions that would give the same results. In isocratic elution, the plate number can be estimated from the peak width (W) and the elution volume (Ve) as N = 16 (Ve/W) 2. The height of the theoretical plate is L/N, where the N increases linearly with L, meaning that the resolution increases with L. The Van Deemter equation (eq. 1) tells how the flow rate and the column affects the plate height (H). The term A stands for longitudinal diffusion, the term B for the equilibrium between the stationary phase and the mobile phase, and the term C is a constant and due to the properties of the column packing. H = A v + B v + C eq. 1 In packed columns the terms A, B and C all contribute to band broadening. A decrease of the particle size will normally influence both the B and C terms thus decreasing the plate height (H), resulting in sharper peaks. [1]. An isocratic elution was used in the experiment to identify the peak of each compound. Isocratic elution represent the case where the mobile phase composition is unchanged during the elution process. If one solvent mixture could not give a rapid elution of all components a gradient elution is often used (Figure 2). Gradient elution provides continuous change of the composition of the solvent to increase the eluent strength. We designed a stepwise linear gradient with two different slopes, one until the ketone was eluted and one to elute the epoxide. Short analysis time can be obtained in many ways, for example by using the shortest possible nonpolar C-18-column, changing the flow rate and the composition of the mobile phase, and by using a gradient elution. 6

7 Materials and Methods Equipment High performance liquid chromatography (HPLC) was carried out using a Chromolith performance RP-18 e column with dimensions of 100x2 mm, using H2O/acetonitrile adjusted to ph3.0 with formic acid is the mobile phase. The system also consisted of a sampler (Shimadzu SIL-10AF), pumps (LC 20AD) and detector (Shimadzu SPDM20A photometric unit). Our experiment was carried out at a flow rate of 0.38 ml/min [2]. The detector was a photodiode array (PDA). Chemicals and materials Styrene oxide, 1-Phenyl-1-2-ethanediol and 2-hydroxyacetophenone were obtained from Sigma Aldrich. 2,3-epoxyprobylbenzene was obtained from TCI. The epoxide hydrolase StEH1 was expressed in E.coli transformed by the plasmid pgtacsteh1-5h, that is a pgtacplasmid with a gene for StEH1 that was extended by 5 histidines by the researchers. Alcohol dehydrogenase AdhA extended by 5 histidines was expressed in E.coli strain BL21-A1. All other chemicals were of analytical grades. Sample preparation Reference sample The compounds styrene oxide, 1-Phenyl-1-2-ethanediol (diol 1) and 2-hydroxyacetophenone (ketone 2) were dissolved in H2O to 3 mm concentration. The incubation samples were prepared as described in appendix 1, Table A1. The compound 2,3-epoxyprobylbenzene (2,3-EPB) was first mixed with only the enzyme StEH1 to obtain the corresponding 3-phenyl-1,2-propanediol (diol 2), to identify the peak of the diol 2. Then 2,3-EPB was mixed with both the enzymes StEH1 and AdhA to obtain the corresponding 3-phenyl-1,2-propanediol (diol 2) and 1-Hydroxy-3-phenylpropan-2-one (ketone 2). The compound 2,3-EPB and the enzymes were dissolved in 0.1M sodium phosphate ph 7.9 to 30 mm concentration. The incubation samples were prepared as described in appendix 2, Table A5. 7

8 Gradient experiment Figure 2- An example of a gradient employed. Gradient elution (dark blue) with acetonitrile (%) plotted over time (min). The gradient was increased from 15 % acetonitrile to 30 % acetonitrile between 5 min and 7 min. And then increased to 90 % acetonitrile between 7 min and 20 min and maintained at 90% acetonitrile for 5 min. Between the time 25:00 and 25:01 the gradient decreased from 90% to 15% to end the experiment. The same general method was used to all the experiments but with different gradients (Table 3). 8

9 The substrates 1- Separation of reaction products with styrene oxide as a starting substrate StEH1 SO H2O 1-Phenyl-1-2-ethanediol (diol 1) AdhA NAD + 2-hydroxyacetophenone (ketone 1) Figure 3- A reaction scheme with SO as starting substrate. SO, diol 1 and ketone 1 were bought from Sigma Aldrich, the compounds were mixed together at 3 mm each in H2O. The sample then run in HPLC and a gradient was used to obtain a shorter analysis time with maintained separation (Table 3 and 4). The experiments in Table 3 were run in duplicate to document the reproducibility. 9

10 2- Separation of reaction products with 2,3-epoxypropylbenzene as a starting substrate StEH1 2,3-EPB H2O 3-phenyl-1,2-propanediol (diol 2) AdhA NAD+ 1-Hydroxy-3-phenylpropan-2-one (ketone 2) Figure 4- A reaction scheme with 2,3-EPB as starting substrate. 2,3-EPB was bought from TCI thus could be analyzed directly whereas diol 2 and ketone 2 were made by the enzymatic reaction in Figure 4. The peaks to the diol 2 and the ketone 2 in this reaction were identified by preparing two samples, one containing only 2,3-EPB (30 mm) and StEH1 to form diol 2 [3] and one containing epoxide 2 (3 mm), StEH1; and AdhA to form the ketone 2 (Table A5). The experiment 3 in table 7 was run in duplicate. 10

11 Results The isocratic separation of SO, 2,3-EPB and the reaction products of SO In order to develop a time optimized analysis of the compounds SO, 2,3-EPB, diol 1 and ketone 1 in the multistep reaction, their analysis times in the unoptimized system were needed to be known. The molecular weight (Mw), concentration, and volume of the compounds are given in Table A1, Appendix 1. The samples were run isocratically with 15% acetonitrile / 85% H2O at a flow rate of 0.38ml/min (Table 2). Table 2- The compounds and their retention time Compounds Retention time (min) SO ,3-EPB ~30 Diol Ketone When the epoxides where run with the longer HPLC C18-column with dimensions of 25 cm x 4.6 mm, 5 µm, the SO had analysis time of 45 min and 2,3-EPB, 75 min, thus by changing the column, the analysis times were decreased. 11

12 Shortening of the analysis time by gradient elution Separation of the substrate styrene oxide and its products A mixture of compounds was prepared as follows: 0.36 µl SO (3 mm) was mixed with 30 µl diol 1 (3 mm) and 30µl ketone 1 (3 mm) in water to a final volume of 1 ml. The sample was then analyzed by a gradient elution (Figure 2), (Table 3 and 4). Table 3- The conditions that were used during isocratic elution and gradient elution. Experiment 1 (isocratic elution) 2 (gradient elution) 3 (gradient elution) 4 (gradient elution) Conditions 15% acetonitrile / 85% H 2O At time 15:00 15:01 min the gradient increased from 15% to 30% acetonitrile. 15:01 20:00 min the gradient increased to 80% acetonitrile. 20:00-20:01 min the gradient decreased to 0% acetonitrile. At time 5:00 7:00 min the gradient increased from 15% to 30% acetonitrile. 7:00 20:00 min the gradient increased to 90% acetonitrile and maintained at it for more 5 min. 25:00-25:01 min the gradient decreased to 15% acetonitrile. At time 00:00 15:00 min the gradient increased from 0% to 90% acetonitrile. 15:00 20:00 min the gradient was decreased to 15% acetonitrile. 20:00-20:01 min the gradient increased to 90% acetonitrile. 20:01-20:03 min the gradient decreased to 15% acetonitrile Table 4- The retention time of the compounds with isocratic elution and gradient elution. Experiment Flow rate (ml/min) Ret. time of diol 1 (min) Ret. time of ketone 1 (min) Ret. time of SO (min) Graph Figure Figure Figure 7 12

13 The traces of experiments 2, 3 and 4 with absorption at 220nm (mau) plotted versus time (min) are shown in Figures 5, 6 and m AU Extract-220nm4nm (1.00) 5.427/ / / m in Figure 5- Retention times of, from left to right, diol 1, ketone 1 and SO in experiment m AU Extract-220nm4nm (1.00) 9.696/ / / m in Figure 6- Retention times of diol 1, ketone 1 and SO in experiment 3. 13

14 1000 m AU Extract-220nm4nm (1.00) / / / m in Figure 7- Retention times of diol 1, ketone 1 and SO in experiment 4. The analysis time was decreased from 45 min to 20 min by using a shorter C-18 column for SO, changing the flow rate and using an optimized gradient. Separation of 2,3-epoxypropylbenzene and its products The diol and the ketone formed from 2,3-EPB, Figure 3, are not commercially available, but could be obtained from the reaction shown in Figure 1. To obtain the ketone, 1-hydroxy-3-phenylpropan-2-one (ketone 2), 2,3-EPB has to be incubated with epoxide hydrolase (StEH1) to obtain phenyl-1.2-propanediol (diol 2). Thereafter, the diol is converted by alcohol dehydrogenase (AdhA) to give ketone 2. Zink is needed to stabilize AdhA and for the enzyme to function. The co-factor NAD + is also needed. To identify the peaks that correspond to the diol and the ketone in this reaction, two samples were prepared (Table A5). Sample 1 contained only 2,3-EPB (30 mm) and StEH1 to obtain diol 2, and sample 2 contained 2,3-EPB (3 mm), StEH1, and AdhA to obtain ketone 2. The retention time of epoxide 2 is approximately 33 min (Table 6). Samples 1 and 2 were first analyzed with isocratic elution, each sample was run for 100 min with 15% acetonitrile/85% H2O (Table 6). Table 6- The retention time of the substrates with isocratic elution. Compounds Retention time (min) 2,3-EPB 32.9 Diol Ketone 2 - Ketone 2 was not obtained because only a very small amount of it was formed, that did not give a clearly visible peak. Since no ketone 2 peak was obtained, a gradient optimized for 14

15 separation of the diol 2 and epoxide 2 only. The mixture was prepared right before the experiment was run to prevent degradation of 2,3-EPB (Tables 7 and 8). Table 7- Conditions used during isocratic and gradient elution. Experiment 1 (isocratic elution) 2 (gradient elution) 3 (gradient elution) Conditions 15% acetonitrile / 85% H 2O At time 5:00 7:00 min the gradient increased from 15% to 30% acetonitrile. 7:00 10:00 min the gradient increased to 80% acetonitrile. 20:00-30:00 min the gradient was increased to 90% acetonitrile. 30:00-30:03 min the gradient was decreased to 15 % acetonitrile. At time 5:00 7:00 min the gradient increased from 15% to 30% acetonitrile. 7:00 10:00 min the gradient increased to 80% acetonitrile. 25:00-30:00 min the gradient was increased to 90% acetonitrile. 30:00-30:03 min the gradient was decreased to 15 % acetonitrile. Table 8- Retention times of compounds with isocratic and gradient elution. Experiment Flow rate (ml/min) Ret. time of diol 2 (min) Ret. time of 2,3-EPB (min) Graph Figure Figure 9 Good separation between the diol 2 and 2,3-EPB was obtained, and good reproducibility was also obtained. 15

16 Chromatograms of experiment 2 and 3, where peaks are detected at 225 nm (figure 8 and 9). 500 m AU Extract-225nm4nm (1.00) / / m in Figure 8- Retention times of, from left to right, diol 2 and 2,3-EPB in experiment m AU Extract-225nm4nm (1.00) / / m in Figure 9- Retention times of diol 2 and 2,3-EPB in experiment 3. 2,3-EPB has absorption maximum of 225 nm where also the diol 2 appears clearly. As can be seen in Figure 8, there is a peak that coelutes with the epoxide peak. It was identified as a degradation product that was formed in the sample. The analysis time was decreased from 75 min to 20 min by using the shorter C-18 column for 2,3-EPB, using gradient elution and could not be decreased more without sacrificing the resolution. 16

17 Discussion The HPLC was chosen because many compounds are not volatile enough for gas chromatography. Since the compounds that we wanted to elute are nonpolar, a nonpolar stationary phase was used with polar mobile phase and a gradient with less polar compound [1]. The mobile phase used here consisted of MilliQ-H2O and acetonitrile adjusted to ph 3 with formic acid. Acetonitrile dissolve both ionic and nonpolar compounds and has a high eluent strength that elutes all compounds rapidly. Acetonitrile was also added to the samples due to solubility problems [4]. The reason why a shorter non-polar C-18 column was used is to obtain good separation at shorter time [5]. The gradient was used to elute tight bound compounds, in this case epoxides, faster. Epoxides are nonpolar compounds why they bound tightly to the nonpolar column. When the acetonitrile concentration is increased, it elutes the epoxides faster because it has a high eluent strength. The diols and the ketones are weakly bound to the column because they are polar, more polar than the epoxides, why they elute faster through the column. 150µl was suitable for a good detectability [6]. The starting substrate styrene oxide By using a shorter C-18 column, changing the flow rate and the gradient, the analysis time of the important compounds could be decreased from 45 min, when a longer C-18 column was used, to 20 min. When the flow rate was increased, sharper peaks with retained separation between the compounds were obtained (Figures 5, 6 and 7). The gradient allowed a good separation for diol 1 and ketone 1 together with a shorter analysis time for SO. The flow rate could not be increased higher than 0.40 ml/min since the shorter C-18 column cannot tolerate higher pressure than 180 bar. The results were as expected, by using higher gradient, as high as 80% or 90% acetonitrile with flow rate of 0.38 ml/min SO was eluted earlier. The analysis times of the compounds could not be further decreased for this system. The reproducibility was checked to confirm the results from the first experiments (Table 3). The results showed good reproducibility for experiment 3 and 4. The reproducibility for experiment 2 could not be tested due storage problems. The start substrate 2,3-epoxypropylbenzene By using the shorter C-18 column and gradient elution, the compounds analysis times could be decreased. The analysis time was decreased from 80 min, when a longer C-18 column was used, to 20 min with good separation. 17

18 Conclusion A gradient and a shorter nonpolar C18-column with dimensions of 100x2 mm were used to shorten the analysis times of the compounds in a multistep reaction. As an example, it would save h if 100 samples were analyzed. A further advantage of shorter analysis times of the compounds is that less solvents would be used. Good reproducibility could also be obtained with the protocol that was used. Personal reflection Shortening the retention time of the epoxides, diols and ketones with retained separation is highly important, since many samples need to be run in HPLC, which is very time consuming. Reducing the analysis times of the compounds helps the researchers to detect the properties of the compounds faster and thus they may detect a treatment. This is why this project was important. To improve the experiment further I would change the flow rate and gradient to obtain better separation between the compounds. I would also try to obtain the ketone 1- Hydroxy-3-phenylpropan-2-one by increasing the concentration of the substrate 2,3-EBP even more. Acknowledgements A big thank You to PhD. Student Åsa Janfalk Carlsson and Prof. Mikael Widersten for supervision. 18

19 References [1] Daniel C. Harris and Michelson Laboratory, High Performance liquid Chromatography, in Quantitative Chemical Analysis, W. H. Freeman and Company, [2]. Janfalk Carlsson. Å, Bauer P., Ma H. and Widersten M., Obtaining optical purity for product diols in enzyme-catalyzed epoxide hydrolysis: contributions from changes in both enantioand regioselectivity, Biochemistry 51, , [3] G. Ann, M. Widersten, Modification of Substrate Specificity Resulting in an Epoxide Hydrolase with Shifted Enantiopreference for (2,3-Epoxypropyl)benzene, Volume 11, , [4] Goldberg A.P., Nowakowska E., Antle P.E., Retention-optimization strategy for the highperformance liquid chromatographic ion-pair separation of samples containing basic compounds, Journal of chromatography 316, , [5] Bahowick J.T., Synovec E.R., Correlation of quantitative analysis Precision to retention time precision and chromatographic resolution for rapid, short-column analysis, Anal. Chem. 67, , [6] L.R. Snyder, J.W. Dolan, J.R. Grant, Gradient elution in high-performance liquid chromatography : I. Theoretical basis for reversed-phase systems, Journal of chromatography Volume 165, 3-30,

20 Appendix Appendix 1. The molecular weight (Mw), concentration, and volume of the compounds SO, diol 1 and ketone 1, see table A1. Table A1- The Mw, mass, concentration, volume and retention time of the compounds. Sample Substance Physical state Mixed with Molecoular weight (g/mol) Mass Conc. (mm) Volume (ml) Retention time (min) 1 SO Liquid Water µl phenyl-1.2- Solid Acetonitrile mg ethanediol 3 2- hydroxyacetophenone Solid Acetonitrile mg Acetonitrile was added due to solubility problems. Appendix 2. The volumes that were used for sample 1 and sample 2, with 2,3-EPB as a start substrate, see Table A5. Table A5- The volume of the substrates and enzymes that were used for sample 1 and 2. Sample Epoxide 2.3-EPB (µl) StEH1 (µl) AdhA (µl) NAD + (µl) Zink (µm) Buffer 0.1M Sodium phosphate ph 7.9 (µl)

21 Appendix 3. Some of the gradient experiments that were run with SO styrene oxide as a start substrate, but failed to give good and shorter retention time. See Table A9 and A10. Table A9- The conditions that were used during isocratic elution and gradient elution. Experiment Conditions 1 15% acetonitrile / 85% H 2O (isocratic elution) 2 At time 15:00 15:01 min the gradient increased from 0% to 15% acetonitrile. 15:01 20:00 min the gradient increased to 80% acetonitrile. 20:00 20:03 min the gradient was still at 80% acetonitrile (gradient elution) 3 At time 7:00 9:00 min the gradient increased from 0% to 15% acetonitrile. 9:00 21:00 min the gradient increased to 30% acetonitrile and maintained at it for more 4 min. 25:00-25:01 min the gradient was decreased to 15% acetonitrile. (gradient elution) 4 At time 7:00 9:00 min the gradient increased from 0% to 15% acetonitrile. 9:00 21:00 min the gradient increased to 90% acetonitrile and maintained at it for more 4 min. 25:00-25:01 min the gradient was decreased to 15% acetonitrile. (gradient elution) 5 At time 8:00 8:01 min the gradient increased from 0% to 20% acetonitrile. 8:01 11:00 min the gradient increased to 90% acetonitrile. 11:01-11:03 min the gradient was decreased to 20% acetonitrile. (gradient elution) Table A10- The retention time of the compounds with isocratic elution and gradient elution. Experiment Flow rate (ml/min) Ret. time of 1-Phenyl-1-2- ethanediol (min) Ret. time of 2- hydroxyacetophenone (min) Ret. time of SO (min) Graph Figure Figure Figure Figure 13 21

22 The graph of experiments 2, 3 and 4 with absorption at 220nm (mau) are plotted versus time (min). The diol 1 and ketone 1 did not have time to form, see figure A m AU Extract-220nm,4nm (1.00) / / / m in Figure A10- Retention times of, from left to right, diol 1 and SO in experiment 2. The graph of experiment 3 with absorption at 220 nm (mau) are plotted versus time (min). The peaks of the diol 1, ketone 1 and SO could either be stuck together or did not have enough time to form, see figure A11. m AU 25 Extract-220nm4nm (1.00) / / / / / m in Figure A11- Retention times of the compounds in experiment 3 are unknown. 22

23 The graph of experiment 4 with absorption at 220 nm (mau) are plotted versus time (min). The diol 1 and ketone 1 did not have enough time to form, see figure A m AU Extract-220nm4nm (1.00) / / / m in Figure A12- Retention times of the diol 1 and SO in experiment 4. The graph of experiment 5 with absorption at 220nm (mau) are plotted versus time (min). The diol 1 and ketone 1 did not have enough time to form and give a good absorbance. Good absorbance is 500 mau, see figure A13. m AU Extract-220nm4nm (1.00) / / / m in Figure A13- Retention times of the diol 1 and SO in experiment 5. The reason why these experiments failed may depends on that the gradient was too high that the diol 1 and ketone 1 did not have enough time to form, or the peaks got stuck together because of that. 23

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK

More information

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012)

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012) July 2012 RITONAVIRI COMPRESSI RITONAVIR TABLETS Final text for addition to The International Pharmacopoeia (July 2012) This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

SUMMARY, CONCLUSION & RECOMMENDATIONS

SUMMARY, CONCLUSION & RECOMMENDATIONS 196 Chapter-5 SUMMARY, CONCLUSION & RECOMMENDATIONS 197 CHAPTER 5 5.1 Summary, Conclusion and Recommendations Summary and Conclusion are drawn based on the work carried out by the author on development

More information

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 129 Infinity LC System Application Note Pharmaceutical and Chemical Analysis

More information

Columns for HPLC. Columns for HPLC

Columns for HPLC. Columns for HPLC Basic principles of preparative HPLC Basically, preparative HPLC follows the same rules as analytical scale chromatography. However, there are important differences in the aims of the two techniques. In

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(1):138-144 Simultaneous RP HPLC determination of Latanoprost

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

Studies on Stationary Phase Selectivity for Solid-Core Particles

Studies on Stationary Phase Selectivity for Solid-Core Particles Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) June 2010 TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) This monograph was adopted at the Forty-fourth WHO Expert Committee on Specifications for Pharmaceutical

More information

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent

More information

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE WORLD JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES Ramalakshmi et al. SJIF Impact Factor 6.647 Volume 7, Issue 2, 1010-1018 Research Article ISSN 2278 4357 METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC

More information

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets Journal of PharmaSciTech 0; ():- Research Article Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets * Sayyed Hussain,

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (11):236-242 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F

More information

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives

More information

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes

More information

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol. 3, No.2, pp 605-609, April-June 2011 RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem

More information

CHAPTER 8 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) ANALYSIS OF PHYTOCHEMICAL CONSTITUENTS OF M. ROXBURGHIANUS AND P. FRATERNUS PLANT EXTRACTS

CHAPTER 8 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) ANALYSIS OF PHYTOCHEMICAL CONSTITUENTS OF M. ROXBURGHIANUS AND P. FRATERNUS PLANT EXTRACTS CHAPTER 8 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) ANALYSIS OF PHYTOCHEMICAL CONSTITUENTS OF M. ROXBURGHIANUS AND P. FRATERNUS PLANT EXTRACTS CHAPTER 8: HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

Isolation of five carotenoid compounds from tangerine tomatoes

Isolation of five carotenoid compounds from tangerine tomatoes Isolation of five carotenoid compounds from tangerine tomatoes Thesis Thomas Haufe Advisor: Steven J. Schwartz, Ph.D Department of Food Science and Technology Presented in fulfillment of the requirements

More information

Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography

Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography Jack E. Silver, jsilver@teledyne.com, Paul Bellinghausen, Nancy Fowler, and Ruth Pipes, Teledyne Isco, Inc.,

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION http://www.rasayanjournal.com Vol.4, No.3 (2011), 666-672 ISSN: 0974-1496 CODEN: RJCABP DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR IN BULK AND ITS PHARMACEUTICAL FORMULATION V.Kalyan Chakravarthy*

More information

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high

More information

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2

More information

Supporting Information

Supporting Information Notes Bull. Korean Chem. Soc. 2013, Vol. 34, No. 1 1 http://dx.doi.org/10.5012/bkcs.2013.34.1.xxx Supporting Information Chemical Constituents of Ficus drupacea Leaves and their α-glucosidase Inhibitory

More information

Fig.1. Denatonium benzoate (DB) chemical structure

Fig.1. Denatonium benzoate (DB) chemical structure ILIADE code 280 CLEN Method Determination of Denatonium Benzoate in Alcoholic Products by HPLC-UV 1 Scope The purpose of this method is verification of fulfilment of the legislative requirements on denatured

More information

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form S. LAVANYA* 1, SK. MANSURA BEGUM 1, K. NAGAMALLESWARA RAO 2, K. GAYATHRI DEVI 3 Department of pharmaceutical

More information

IAM Chromatography. Introduction

IAM Chromatography. Introduction IAM Chromatography IAM Drug Discovery Columns Introduction References: 1. Regis 1998-99 Chromatography Catalog A simple, rapid method to predict drug transport across biological barriers has been a long

More information

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Application Note Environmental Author Melanie Metzlaff Agilent Technologies, Inc. Waldbronn, Germany Abstract

More information

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract JJC Jordan Journal of Chemistry Vol. 4 No.4, 2009, pp. 357-365 Development and Validation of Analytical Method for Fluconazole and Fluconazole Related Compounds (A, B, and C) in Capsule Formulations by

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION http://www.rasayanjournal.com Vol.4, No.1 (2011), 165-171 ISSN: 0974-1496 CODEN: RJCABP DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR AND ITS PHARMACEUTICAL FORMULATION V. Kalyana Chakravarthy * and

More information

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW 132 CHAPTER 6 DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF PARACETAMOL, TRAMADOL HYDROCHLORIDE AND DOMPERIDONE IN A COMBINED DOSAGE FORM 6.1 INTRODUCTION

More information

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Method development and validation of tenofovir disoproxil fumerate and emtricitabine in combined tablet

More information

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector application Note Liquid Chromatography Author Njies Pedjie PerkinElmer, Inc. Shelton, CT 06484 USA Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped

More information

Determination of taurine in energy drinks by high-performance liquid chromatography

Determination of taurine in energy drinks by high-performance liquid chromatography Determination of taurine in energy drinks by high-performance liquid chromatography Brad McConn Department of Chemistry, Concordia College, 901 8 th St S, Moorhead, MN 56562 Abstract The concentration

More information

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms Asian Journal of Chemistry Vol. 22, No. 7 (2010), 5067-5071 RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms A. LAKSHMANA RAO*, G. TARAKA RAMESH and J.V.L.N.S. RAO Department of Pharmaceutical

More information

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki

More information

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method International Journal of Chemical and Pharmaceutical Sciences 2017, Mar., Vol. 8 (1) ISSN: 0976-9390 IJCPS Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

2D-LC as an Automated Desalting Tool for MSD Analysis

2D-LC as an Automated Desalting Tool for MSD Analysis 2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras) C 19 H 30 N 5 O 10 P. C 4 H 4 O 4 Relative molecular mass. 635.5. Chemical names. bis(1-methylethyl) 5-{[(1R)-2-(6-amino-9H-purin-9-yl)-1-methylethoxy]methyl}-5-oxo-2,4,6,8-tetraoxa-5-λ 5 - phosphanonanedioate

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 11(4), 2013, 1607-1614 ISSN 0972-768X www.sadgurupublications.com DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

More information

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Method development of cytotoxic drugs selectivity IAC Seminar, 06.03.2015 Content Introduction Definition

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015) August 2015 Document for comment 1 2 3 4 5 CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA (AUGUST 2015) DRAFT FOR COMMENT 6 Should you have any comments

More information

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC METHOD APPROVALS Norvin Pharma Inc. Author Analytical Laboratory Approver Analytical Laboratory Group Leader Approver Manager Quality Control Chemistry

More information

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow APPLICATIN NTE 7601 Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow Authors Sylvia Grosse, Mauro De Pra, Frank Steiner Thermo Fisher Scientific, Germering, Germany

More information

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory

More information

Scholars Research Library

Scholars Research Library Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 2010, 2(5): 46-52 (http://derpharmachemica.com/archive.html) ISSN 0975-413X CODEN (USA): PCHHAX Development and

More information

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD 170 Original Article SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD *Lakshmana Rao A, 1 Bhaskara Raju V *V.V. Institute of Pharmaceutical Sciences, Gudlavalleru,

More information

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW 51 CHAPTER 2 SIMULTANEOUS ESTIMATION OF PIOGLITAZONE, GLIMEPIRIDE AND GLIMEPIRIDE IMPURITIES IN COMBINATION DRUG PRODUCT BY A VALIDATED STABILITY-INDICATING RP-HPLC METHOD 2.1 INTRODUCTION OF DOSAGE FORM

More information

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC Analysis of Counterfeit Antidiabetic Drugs by UPLC with the Agilent 1 Infinity Mobile LC Application Note Small Molecule Pharmaceuticals & Generics Author Sonja Schneider Agilent Technologies, Inc. Waldbronn,

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(2):770-775 Validation of Rapid Liquid Chromatographic

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method ISSN: 0973-4945; CODEN ECJAO E- Chemistry http://www.e-journals.net 2012, 9(1), 340-344 Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by PLC Method V.

More information

An Investigative Study of Reactions Involving Glucosinolates and Isothiocyanates

An Investigative Study of Reactions Involving Glucosinolates and Isothiocyanates An Investigative Study of Reactions Involving Glucosinolates and Isothiocyanates Alzea Chrisel H. Alea 1, Diane Elaine T. Co 2 and Marissa G Noel 3* 1,2,3Chemistry Department, De La Salle University, 2401

More information

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms OPEN ACCESS Eurasian Journal of Analytical Chemistry ISSN: 1306-3057 2017 12(2):31-44 DOI 10.12973/ejac.2017.00152a A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide

More information

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector application Note UHPLC Author Njies Pedjie PerkinElmer, Inc. Shelton, CT 06484 USA Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector Introduction Foods

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC Asian Journal of Chemistry Vol. 21, No. 8 (9), 5979-5983 Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC V. KIRAN KUMAR* and N. APPALA RAJU Department of Pharmaceutical Analysis, Sree Chaitanya

More information

World Journal of Pharmaceutical Research

World Journal of Pharmaceutical Research World Journal of Pharmaceutical ReseaRch Volume 3, Issue 3, 4527-4535. Research Article ISSN 2277 715 DEVELOPMENT AND VALIDATION OF STABILITY INDICATING HPLC METHOD FOR ESTIMATION OF RAMOSETRON Zarana

More information

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE Int. J. Chem. Sci.: 6(1), 2008, 441-446 A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE S. APPALA RAJU, ARVIND B. KARADI and SHOBHA MANJUNATH HKES s College of Pharmacy,

More information

Column Stability and Performance under High Temperature HPLC Conditions

Column Stability and Performance under High Temperature HPLC Conditions Column Stability and Performance under High Temperature HPLC Conditions Stephanie J. Marin Brian Jones, Dale Felix, Jody Clark Selerity Technologies, Inc. Salt Lake City, UT www.selerity.com Introduction

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES RPID ND SENSITIVE PLC/V/MS METD FR SIMVSTTIN ND LV S TT IN IN S P P RT F C L E NING V L I DT I N S T DIES Erin Chambers, Diane Diehl, and Jeff Mazzeo Waters Corporation, Milford, M, S BCKGRND tilizing

More information

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C.

More information

A biocatalytic hydrogenation of carboxylic acids

A biocatalytic hydrogenation of carboxylic acids Electronic Supplementary Information (ESI) for: A biocatalytic hydrogenation of carboxylic acids Yan Ni, Peter-Leon Hagedoorn,* Jian-He Xu, Isabel Arends, Frank Hollmann* 1. General Chemicals All the carboxylic

More information

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at  RESEARCH ARTICLE Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), 26-30 26 Available online at http://jddtonline.info RESEARCH ARTICLE METHOD DEVELOPMENT AND ITS VALIDATION FOR QUANTITATIVE SIMULTANEOUS

More information

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2 JPSBR: Volume 5, Issue 2: 2015 (151-155) ISS. 2271-3681 A ew Gradient RP- HPLC Method for Quantitative Analysis of : (3-luoro-4- Morpholin-4-yl-Phenyl)-Carbamic Acid Methyl Ester and its Related Substances

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2014, 5(5):91-98 ISSN: 0976-8688 CODEN (USA): PSHIBD A novel RP-HPLC method development and validation of Perindopril Erbumine in

More information

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column P-CN54E Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column Pittcon 5 9-6P Kenichiro Tanaka, William Hedgepeth, Yuki Sato Shimadzu Scientific Instruments,

More information

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079 Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for

More information

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine- Analysis of Pharmaceutical Substances Using HPLC and UHPLC Methods Backward Compatibility for Validated Analytical Procedures and Methods Comparing the Infi nity LC and the Infi nity II LC Application

More information

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET International Journal of Pharma and Bio Sciences RESEARCH ARTICLE ANALYTICAL CHEMISTRY DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET K.MYTHILI *, S.GAYATRI,

More information

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India. International Journal On Engineering Technology and Sciences IJETS RP-HPLC Method development and validation for the Simultaneous Estimation of Metformin and Empagliflozine in Tablet Dosage Form Shaik

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (http://scholarsresearchlibrary.com/archive.html)

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (http://scholarsresearchlibrary.com/archive.html) Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (6):217-223 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

Analysis of HMF by HPLC

Analysis of HMF by HPLC COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl

More information

Development and Validation of a RPLC Method for the Determination of 2-Phenoxyethanol in Senselle Lubricant Formulation

Development and Validation of a RPLC Method for the Determination of 2-Phenoxyethanol in Senselle Lubricant Formulation Research Paper Development and Validation of a RPLC Method for the Determination of 2-Phenoxyethanol in Senselle Lubricant Formulation G. A. SHABIR*, T. K. BRADSHAW, G. Q. SHAR 1 AND S. A. ARAIN 2 Oxford

More information

Jagua (Genipin-Glycine) Blue (Tentative)

Jagua (Genipin-Glycine) Blue (Tentative) 0 out of 9 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 Jagua (Genipin-Glycine) Blue (Tentative) This monograph was also

More information

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40 International Research Journal of Pharmaceutical and Applied Sciences Available online at www.irjpas.com Int. Res J Pharm. App Sci., 2012; 2(4):35-40 Research Article Estimation of Fesoterodine fumarate

More information

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16 Asian Journal of Pharmaceutical Technology & Innovation ISSN: 2347-8810 Research Article Received on: 30-03-2016 Accepted on: 01-04-2016 Published on: 15-04-2016 Corresponding Author: *Pankti M. Shah,

More information

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC Chapter III Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC 1. INTRODUCTION Phenolics compounds are naturally present antioxidants, found in a variety of plant

More information

Supplementary Material

Supplementary Material Supplementary Material Antimicrobial mechanism of theaflavins: They target 1-deoxy-D-xylulose 5-phosphate reductoisomerase, the key enzyme of the MEP terpenoid biosynthetic pathway Xian Hui, Qiao Yue,

More information

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 19 Infinity LC system Application Note Food Authors Standard solution Gerd Vanhoenacker, Frank David, Pat Sandra Research

More information