Designing an Extractables and Leachables Study
|
|
- Marilyn Lambert
- 6 years ago
- Views:
Transcription
1 Designing an Extractables and Leachables Study 1
2 2 Overview
3 Background InformaAon Materials of Construction What addiaves are used? MulAlayer films? PrinAng Inks? Finished Packaging Which surfaces does the product contact? Are there interacaons between components? Is there opportunity for non- product contact components to migrate? Are there any processing aids used? 3
4 Use CondiAons How will it be used? How should it be extracted? Extractables challenge the use condi/on Temperature Solvent Strength Time Leachables mimic the most stringent use condi/on 4
5 ExtracAon Strategies Cut and Cover MulAlayer Films Cap Liners Printed Packaging Containers based on Homo-polymers Irregularly shaped Large Simple containers systems Extraction Irregularly shaped ArAcles requiring two- sided extracaon Cut and Cover Very large containers ExtracAon 5
6 ExtracAon Strategies MulAlayer Films Cap Liners Printed Packaging MulAlayer Films Printed Packaging Bags Small containers Tubing Non-permeable Printed containers Full Fill Extraction 6
7 ExtracAon Strategies MulAlayer Films Cap Liners Printed Packaging MulAlayer Films Printed Packaging MulA- layer Printed materials Coated materials Product contacts one side One- Sided Extraction 7
8 ExtracAon Strategies Tubing MulAlayer Films Cap Liners Printed Packaging MulAlayer Films Printed Packaging Complex systems In- Line filters Connectors Flow Through Extraction 8
9 ExtracAon Strategies MulAlayer Films Cap Liners Printed Packaging MulAlayer Films Printed Packaging Direct analysis of the enare aracle Very high sensiavity No risk of volaales loss Large Volume Dynamic Headspace 9
10 ExtracAon Solvent From the background informaaon provided for a container closure system the probable extractables were: Expected Extractable Type Log P Boiling point Erucamide Hydrophobic C Linear Alkanes Hydrophobic C Dibutylphthalate Hydrophobic C Dimethoxyethane VolaAle C Irganox 1010 Non- volaale 23 N/A Irgafos 168 Non- volaale 15.5 N/A Tinuvin 770 Basic 6.3 N/A Stearic acid Acidic C Sodium benzenesulfonate Anionic N/A N/A 10
11 Effect of Solvent Polarity Agilent 1290 Infinity UHPLC; Agilent 6520 QTOF- MS Column: Agilent Zorbax Eclipse Plus C8; 1.8 µm, mm Electrospray IonizaAon (ESI); Polarity: posiave 11
12 Extract PreparaAon Example: 250 ml per bag Worst case 3 bags per day Product contact surface area 310 cm 2 Safety concern threshold (SCT) = 0.15µg/ day AET( µμg/bag )= 0.15 µμg day /3 bags day =0.05 µμg/bag Extract Vol. (ml)= 310 cm 2 /6 cm 2 ml =52 ml LOD= 0.05 µμg bag /52 ml bag 1 ng ml 12
13 13 QualitaAve Analysis
14 ConcentraAon of Extracts Extractables & Leachables can be lost during concentration Loss depends on VolaAlity of the analyte(s) Extract handling Best PracAces Mild condiaons Method validaaon Headspace analysis 14
15 QualitaAve Analysis No universal analyhcal technique exists for E&L analysis QTOF- GCMS HGCMS QTOF- LCMS Headspace GCMS VolaAles QTOF- GCMS VolaAles Semi- volaales Non- polar analytes QTOF- LCMS Polar/ionizable ICP- MS Metals 15
16 ExtracAon CondiAons - - Ethanol Extract- - Expected Extractables Type Log P Boiling point Erucamide Hydrophobic C Linear Alkanes Hydrophobic C Dibutylphthalate Hydrophobic C Dimethoxyethane VolaAle C Irganox 1010 Non- volaale 23 N/A Irgafos 168 Non- volaale 15.5 N/A Tinuvin 770 Basic 6.3 N/A Stearic acid Acidic C Sodium benzenesulfonate Anionic N/A N/A 16
17 QualitaAve Analysis Agilent 1290 Infinity UHPLC; Agilent 6520 QTOF- MS Column: Agilent Zorbax Eclipse Plus C8; 1.8 µm, mm Electrospray IonizaAon (ESI) 17
18 QualitaAve Analysis Agilent 7890B GC; Agilent 7200 QTOF- MS Column: DB- 5MS UI; 0.25 mm 30 m, 0.25 µm Electron Impact IonizaAon 18
19 QualitaAve Analysis Agilent 6890 GC; Agilent 5973 inert MSD Electron Impact IonizaAon 19
20 QualitaAve Analysis Technique Analyte Boiling Point ( C) HGCMS QTOF- GCMS QTOF- LCMS Dimethoxyethane 85 C Hexadecane 286 C Linear Alkanes C Dibutylphthalate 340 C Tinuvin 770 >350 C Irgafos 168 N.A. Stearic Acid 361 C Erucylamide 474 C Irganox 1010 Non- VolaAle 20
21 IdenAficaAon of Unknowns Database Searches Commercial Databases (NIST, Wiley) Jordi Proprietary AddiAve and Oligomer Databases QTOF- GC / QTOF- LC Molecular Formula GeneraAon (MFG) MS/MS for QTOF - LCMS CI for QTOF- GCMS 21
22 IdenAficaAon of Unknowns Score Diff. m/z Best Match Species Mass DBE (MFG) (ppm) C 16 H 35 N O 2 [M+H]
23 IdenAficaAon of Unknowns Fragment Ion Best Match Score Possible Structure [C 16 H 34 N O] [C 14 H 32 N O] [C 4 H 12 N O 2 ] [C 4 H 10 N O]
24 QuanAtaAve Strategies Relative Quantitation QuanAficaAon of compounds observed is performed against surrogate standards Accuracy depends on the surrogate standard used Estimated Analyte Conc.= Observed Analyte Peak Area/Surrogate Peak Area Surrogate Conc. 24
25 25 QuanAtaAve Strategies
26 QuanAtaAve Strategies Formal Quantitation Confirmed compounds are quanafied against an analyacal standard at a series of concentraaons Methodologies: External StandardizaAon Standard AddiAon Requires high purity analyacal standards 26
27 27 QuanAtaAve Strategies
28 QuanAtaAve Method Development QuanAtaAve Methods Dynamic Headspace GCMS UHPLC- UV UHPLC- CAD QTOF- GCMS In formal quanataaon limit of quanataaon (LOQ) can be improved using: Targeted MS/MS Large Volume InjecAon 28
29 QuanAtaAve Method Development Agilent 1290 Infinity UHPLC Column: Zorbax SB- C18, 1.8 µm, mm Mobile Phase: H 2 O ACN Grad. DetecAon: 230 nm (DAD) 29
30 2D UHPLC Quaternary Pump Column 1 VWD Loop Valve Waste FLD DAD Column 2 VWD Variable Wavelength Detector DAD Diode Array Detector FLD Fluorescence Detector Binary Pump 30
31 QuanAtaAve Method Development Column: Zorbax SB- C18; 1.8 µm, mm Mobile Phase: H 2 O ACN Gradient DetecAon: 230 nm (VWD) CollecAon Mode: Heart- curng; minutes (40 µl) 31
32 QuanAtaAve Method Development Column: Eclipse Plus Phenyl- Hexyl; 1.8 µm, mm Mobile Phase: H 2 O ACN IsocraAc DetecAon: 230 nm (DAD) 32
33 QuanAtaAve Method Development Column: Eclipse Plus Phenyl- Hexyl; 1.8 µm, mm Mobile Phase: H 2 O ACN IsocraAc DetecAon: Fluorescence; 225 nm excitaaon, 310 nm emission 33
34 A SUCCESSFUL STUDY HAS: 1. Appropriate ExtracAon CondiAons 2. Careful ConcentraAon of Extracts 3. DefiniAve IdenAficaAons 4. Accurate QuanAficaAon 34
Extractables and Leachables from Single Use Bioprocess Systems
Extractables and Leachables from Single Use Bioprocess Systems 1 Founded in 1980 Medical Devices Food Packaging P harmaceutical Over Extractables Leachables 1,000 Projects Annually IDENTIFICATION QUANTIFICATION
More informationMass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System
Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationApplication Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-
Analysis of Pharmaceutical Substances Using HPLC and UHPLC Methods Backward Compatibility for Validated Analytical Procedures and Methods Comparing the Infi nity LC and the Infi nity II LC Application
More informationEffective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate
Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,
More informationProbing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION
Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is
More informationIdentification of Steroids in Water by Ion Trap LC/MS/MS Application
Identification of Steroids in Water by Ion Trap LC/MS/MS Application Environmental Author Paul Zavitsanos and Christine Miller Agilent Technologies, Inc. Centerville Road Wilmington, DE 9- USA Abstract
More informationApplication Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.
Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2
More informationBenefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University
Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University Mass Spectrometry Structure Elucidation Selective and Sensitive Detection Identification
More informationApplication Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.
Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling Application Note Food 1 Agilent 12 Infinity 1 Author Siji Joseph Agilent Technologies, Inc. Bangalore,
More informationChiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System
Application Note Small Molecule Pharmaceutical Chiral Screening for SFC and UHPLC with the Agilent 16 Infinity II SFC/UHPLC Hybrid System Author Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany
More informationUsing Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.
Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in
More informationSeparation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement
Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Application Note Food Testing & Agriculture Author Edgar Naegele Agilent Technologies,
More informationQualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection
Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D
More informationPerformance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat
Performance Characteristics of the Agilent 9 Infinity II Multicolumn Thermostat Technical Overview Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview
More informationCannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D
More informationAuthors. Abstract. Introduction. Environmental
Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,
More informationRapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit
Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent
More informationLipidomic Analysis by UPLC-QTOF MS
Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material
More information2D-LC as an Automated Desalting Tool for MSD Analysis
2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja
More informationANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.
Vodovodna 95, 1000 LJUBLJANA, SLOVENIA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine
More informationAnalytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP
Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract
More informationANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 N-methyl-2AI ( C10H13N) N-methyl-2,3-dihydro-1H-inden-2-amine
More informationTransferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC
Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Application Note Environmental Author Melanie Metzlaff Agilent Technologies, Inc. Waldbronn, Germany Abstract
More informationANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate
Vodovodna 95 1000 Ljubljana SLOVENIJA ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate Remark other NPS detected: none Sample
More informationEdgar Naegele. Abstract
Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in
More informationANALYTICAL REPORT 1, 2
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1, 2 Phenibut (C10H13NO2) 4-amino-3-phenylbutanoic acid
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationHPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil
HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil Application Note Authors Xueqi Li, Selina Wang UC Davis Olive Center Robert
More informationImpurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF
Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE
More informationAgilent 1220 Infinity LC System Performance Specifications
IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance
More informationANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine.
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine
More informationProfiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography
Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Application Note Metabolomics Author Yuqin Dai Agilent Technologies, Inc. 31 Stevens Creek Blvd,
More informationANALYTICAL REPORT 1, 2
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1, 2 4-MEAP (C14H21NO) 2-(ethylamino)-1-(4-methylphenyl)pentan-1-one
More informationHigh-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System
High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System Application Note Food, Hydrocarbon Processing Authors Michael Woodman Agilent Technologies,
More informationPHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,
PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES DR. A. RAMESH, Ph.D, D.Sc., raamesh_a@yahoo.co.in 1 OBJECTIVES Determination of persistence and photolysis
More informationANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one
More informationSelectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants
Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More informationJournal of Chemical and Pharmaceutical Research
Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(2):770-775 Validation of Rapid Liquid Chromatographic
More informationSUPPLEMENTARY MATERIAL
SUPPLEMENTARY MATERIAL Artepillin C, is it a good marker for quality control of Brazilian Green Propolis? Cui-ping Zhang 1, Xiao-ge Shen 1, Jia-wei Chen 1, Xia-sen Jiang 1, Kai Wang 2, Fu-liang Hu 1 *
More informationAm I getting the very best value from my UHPLC analyses?
Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run
More informationFig.1. Denatonium benzoate (DB) chemical structure
ILIADE code 280 CLEN Method Determination of Denatonium Benzoate in Alcoholic Products by HPLC-UV 1 Scope The purpose of this method is verification of fulfilment of the legislative requirements on denatured
More informationReduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa
Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Application Note Small Molecule Pharmaceuticals & Generics Author Mike Chang Agilent Technologies, Inc. 5 Commercentre
More informationQualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution
Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Application Note Food Testing Author Edgar Naegele
More informationAutomated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System
Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography
More informationSue D Antonio Application Chemist Cedar Creek, TX
Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis
More informationLOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016
LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES Gilles Frache Materials Characterization Day October 14 th 2016 1 MOLECULAR ANALYSES Which focus? LOCALIZATION of molecules by Mass Spectrometry
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Sean Orlowicz LC/MS Product Specialist Agilent Technologies 31August Agilent s > 40 year heritage in mass spectrometry 1971, 5930A GC/MS 1971-2011 2005,
More informationFat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column
Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C8 Bonded Column Application Note Food Authors Rongjie FU Agilent Technologies (Shanghai) Co. Ltd. Ying Lun Road Waigaoqiao Free
More informationIncreasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System
Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 129 Infinity LC System Application Note Pharmaceutical and Chemical Analysis
More informationThe One Minute Chromatographer
The One Minute Chromatographer Agilent Technologies, Inc. 2013 Page 1 Sub 1 Minute Separations with RRHD Columns Agilent ZORBAX RRHD SB-C18, 2.1 x 100mm, 1.8 µm H2O (0.05% Formic acid) / 2-98 % Acetonitrile
More informationOnline 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution
Online D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 19 Infinity D-LC Solution Comprehensive and Multiple Heart-Cutting D-LC Analysis for Highest Resolution Application Note
More informationMALAYSIAN MALAYSIAN COCOA WORKSHOP ON THE SAFE USE OF PESTICIDES IN COCOA AND HARMONIZED
COCOA WORKSHOP ON THE SAFE USE OF PESTICIDES IN COCOA AND HARMONIZED Pesticides - Commonly used in cocoa production Residue problems - health hazard GAP & Legislation CODEX Alimentarius - introduced and
More informationComprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids
PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki
More informationAgilent 1260 Infinity Analytical SFC System
Agilent 1260 Infinity Analytical SFC System Installation Instructions: Checkout Procedure This technical note describes the checkout procedures for the Agilent 1260 Infinity Analytical SFC System. Contents
More informationSteviol Glycosides from Stevia rebaudiana Bertoni
0 out of 21 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 Steviol Glycosides from Stevia rebaudiana Bertoni This monograph
More informationComparison of Relative Quantification of Monoclonal Antibody N-glycans Using Fluorescence and MS Detection
Comparison of Relative Quantification of Monoclonal ntibody N-glycans Using Fluorescence and MS Detection pplication Note iotherapeutics & iologics uthors scar Potter and Gregory Staples gilent Technologies,
More informationACE C18-AR Use the Power!
combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety
More informationDevelopment and Validation of RP-HPLC Method for the Estimation of Gemigliptin
Human Journals Research Article September 2018 Vol.:13, Issue:2 All rights are reserved by Hajera Khan et al. Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin Keywords: Gemigliptin,
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationAnalysis of Antioxidants in Vegetable Oils Using the Agilent 1260 Infinity Hybrid SFC/UHPLC System with MS Detection
Analysis of Antioxidants in Vegetable Oils Using the Agilent Infinity Hybrid SFC/UHPLC System with MS Detection Application Note Food Analysis & Agriculture Authors Maria Rambla-Alegre, Melissa N. Dunkle,
More informationQualification of Drug Product Contact Materials used in Small Volume Parenterals (SVP): Chemistry Considerations Edward J. Smith, Ph.D.
PQRI Workshop Thresholds and Best Practices for Parenteral and Ophthalmic Drug Products (PODP) Qualification of Drug Product Contact Materials used in Small Volume Parenterals (SVP): Chemistry Considerations
More informationAnalysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column
Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic
More informationAnalysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN
Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words
More informationWorkflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF
APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Joanne Mather PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Urine
More informationQuantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System
Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for
More informationAnalysis of HMF by HPLC
COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationAgilent Technologies Prep LC Columns
Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies
More informationConverting a CHP Method for Insulin to Agilent Poroshell 120 Columns
Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory
More informationAnalytical Workflow for Extractable and Leachable Impurities
Analytical Workflow for Extractable and Leachable Impurities AAPS 2015 26 October 2015, Orlando FL Kyle D Silva The world leader in serving science WHAT are EXTRACTABLES and LEACHABLES? 2 3 What is E&L
More informationAnalysis of bisphenol A leaching from baby feeding bottles
Agilent Application Solution Analysis of bisphenol A leaching from baby feeding bottles Application Note Consumer Products Author Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India Abstract
More informationEnhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase
Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Subhra Bhattacharya and Stephen C. Roemer Thermo Fisher Scientific Global Chemicals, Fair Lawn, NJ, USA AbstrAct Liquid
More informationAnalytical and Preparative SFC Columns
Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...
More informationAccumulation and transformation of inorganic and organic arsenic in rice and role of
Supplementary Information: Accumulation and transformation of inorganic and organic arsenic in rice and role of thiol-complexation to restrict their translocation to shoot Seema Mishra 1,2 *, Jürgen Mattusch
More informationApplication Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products
High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C.
More informationA Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer
A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract
More informationSepax Technologies, Inc.
Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid
More informationSummary Chapter 8 CHAPTER 8. Summary. Page 173
CHAPTER 8 Summary Page 173 Chapter 2: Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitative Estimation of PEG 400 and its Applications A rapid sensitive and selective MRM based method
More informationQuantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer
application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate
More informationMaximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system
Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author
More information4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column
Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method
More informationDevelopment of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid
Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary
More informationDetermination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry
Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent
More informationApplication Note. Authors. Abstract. Food
Determination of Hormones in Shrimp by Agilent 129 Infinity LC with Agilent Poroshell 12 LC Column and Agilent Bond Elut QuEChERS for Sample Preparation Application Note Food Authors Rongjie Fu and Andy
More informationAnalytical Challenges in Veterinary Toxicology: Bromethalin
Analytical Challenges in Veterinary Toxicology: Bromethalin Mike Filigenzi, Birgit Puschner, Linda Aston, Robert Poppenga CAHFS-UC Davis School of Veterinary Medicine First things first: Acknowledgements
More informationExtended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions
Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions Application Note Targeted Proteomics Authors Linfeng Wu, Christine A. Miller, Jordy Hsiao, Te-wei Chu, Behrooz
More informationChiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System
Chiral Multicolumn Method Development on the Agilent 126 Infinity II SFC System Application Note Small Molecule Pharmaceuticals Author Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Abstract
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationUptake and Metabolism of Phthalate Esters by Edible Plants
1 Supporting Information for 2 3 Uptake and Metabolism of Phthalate Esters by Edible Plants 4 Jianqiang Sun, Xiaoqin Wu, Jay Gan * 5 6 7 Department of Environmental Sciences, University of California,
More informationDetermination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.
Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are
More informationSUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM
SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM UNITED KINGDOM WOMEN DO NOT DECREASE OVER TWELVE MONTHS
More informationDevelopment and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma
1 Development and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma Rohini Narayanaswamy University At Buffalo, The State University of New York
More informationUltra High Definition Optimizing all Analytical Dimensions
Ultra High Definition Optimizing all Analytical Dimensions Sensitivity Dynamic Range Signal Response Linearity Separation Speed Peak Capacity Chromatogram Mass Spectrum Mass Accuracy Resolving Power Acquisition
More informationANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION
ANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION Overview This document describes the test program for qualifying Agilent LCMS systems. The following tables list all MS source-specific OQ
More informationInfinityLab Purification Capillary Kits
InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies Contents Abbreviations 3 List of Modules 4 Overview
More informationApproaches for the determination of NIAS as a part of Safety-By-Design
Approaches for the determination of NIAS as a part of Safety-By-Design M. Driffield 1, M. Garcia-Lopez 1, E.L. Bradley 1, P.T.K. Oldring 2 1 Fera Science Ltd, 2 Valspar Corp. malcolm.driffield@fera.co.uk
More informationANALYTICAL REPORT. 1-(1,3-diphenylpropan-2-yl)pyrrolidine (C19H23N) 1-(1,3-diphenylpropan-2-yl)pyrrolidine
Vodovodna 95, 1000 LJUBLJANA, SLOVENIA E: nfl@policija.si Remark other NPS detected: none ANALYTICAL REPORT 1-(1,3-diphenylpropan-2-yl)pyrrolidine (C19H23N) 1-(1,3-diphenylpropan-2-yl)pyrrolidine Sample
More information