Chemical Analysis Business Operations Waters Corporation Milford MA

Size: px
Start display at page:

Download "Chemical Analysis Business Operations Waters Corporation Milford MA"

Transcription

1 The Detection and Identification of Unknown Contaminants During ToF Screening and Structural Elucidation for Pesticides in River Water Using an Integrated Software Approach Chemical Analysis Business Operations Waters Corporation Milford MA

2 Streamlined Screening Workflow Prepare samples Generic sample extraction Pre concentrate and clean-up Acquire comprehensive sample data High resolution chromatography and MS detection Simultaneous molecular ion and fragment ion data Locate and identify known components Maximise MS information Determine significance with quantification 4 Identify unknown peaks of interest Deconvolution of molecular ion and fragment ion data Comparing against known good sample or controls 5 Elucidate structures of unknowns Elemental composition determinations, online search Software based mass spectral interpretation 211 Waters Corporation COMPANY CONFIDENTIAL 2

3 Screening Enabling Technologies Oasis HLB SPE Efficient water extraction Xevo G2 QTof QuanTOF technology 2, resolution MS E enabled POSI±IVE workflow software Targeted screening using compound database ChromaLynx XS, MassFragment Locate and identify non-targeted unknown components

4 Rapid and Comprehensive data Rapid and Comprehensive data acquisition

5 Speed AND Resolution MS E with rapid chromatography Fastnet_431_water68 F Da e4 28 datapoints across spiroxamine peak Fastnet_431_water68 Fragments = 14 data points F Da e4 MS E = All the masses in ONE injection m/z = M =. ppm Fastnet_431_water F Da 9.4e4 Time Hundreds of Pesticides, <85 seconds m/z = M = 1.3 ppm Time Precursors = 14 data points

6 Speed AND Resolution MS E with rapid chromatography Fastnet_431_water68 F Da e4 Fastnet_131_water7 1 1: TOF MS ES Da 1.2e5 Ultra fast for simple matrices Medium speed for normal matrices Time Fastnet_631_water_15 1 1: TOF MS ES Da Time e4 Maximum resolution for the most complex matrices 3.42 Time

7 Comprehensive Data Acquisition - UPLC/MS E Simple, patented method for unbiased data acquisition Catalogs complex samples in a single analysis Comprehensive record of precursor and fragment ion data

8 Comprehensive Fragment ion High Speeds LE LE m1 sec EE D. EE MS E is a UNBIASED process All ions all the time Bateman et al, Anal Chem (22) Silva et al, MCP (25) *Patented technology EE EE 211 Waters Corporation COMPANY CONFIDENTIAL 8

9 Matrix Tolerance

10 In Spectrum Dynamic range - Matrix Tolerance 1 XIC m/z TIC m/z Time Malaoxon in sewage effluent,.2 µg/l Theoretical mass = m/z

11 Stability and Selectivity

12 Mass Stability Essential for High Quality Data Thiabendazole 2 ppb Scan No. Measured Mass M (mda) M (ppm) RMS = Excellent mass accuracy across peak m/z m/z 22.5

13 Targeted Screening Narrow XIC Windows mda 1 XIC fragment m/z mda mda mda Mass accuracy + stability ypermits use of narrow XICs XIC precursor m/z TIC mda T 1.3 mda.9 Time Fenuron m/z Thiabendazole High selectivity for precursors and fragments with MS E

14 Reducing False Positives Narrow XIC Windows Monuron m/z Fenazox m/z Cymoxamil m/z mda Mass extraction window 3. mda

15 S l ti it i i hi h l ti Selectivity gains using high resolution fragment ions

16 Comprehensive Data Acquisition - Resolve Isobaric Precursors with MS E 1 Desmetryn m/z Desmetryn Simetryn m/z Desmetryn m/z Simetryn m/z Time Simetryn or Desmetryn? m/z m/z Selective MS E fragment in standards

17 Screening Against a Target List of Screening Against a Target List of Compounds

18 Experimental 2 ml UK River Water Oaisis HLB Cartridge (2x concentration) ACQUITY UPLC System Runtime: 5 min Flow Rate:.6 ml/min Injection: 3. L Column: ACQUITY BEH C 18, 1.7 m, 2.1 x 5 mm (45 o C) Mobile Phase: A) Ammonium Acetate in Water. B) Ammonium Acetate in Methanol Time (min) Flow rate (ml/min) A B Curve Initial Waters Corporation COMPANY CONFIDENTIAL 18

19 Experimental Continued MS system: Xevo G2 QTof (Figure 1) Ionization mode: ESI positive Analyser: Resolution mode (>2K resolution) Scan time: 1.1 s Capillary voltage: 1. kv Sampling cone: 3. V Source temp: 12 o C Desolvation temp: 55 o C Mass range: m/z 5 1 MS E Low energy: 6. V MS E High energy: V LockSpray solution: Leucine enkephalin LockSpray masses: m/z and m/z Waters Corporation COMPANY CONFIDENTIAL 19

20 Screening against a Target List Non-selective sample extraction Non-Targeted (Unbiased) Data Acquisition Acquire single comprehensive dataset with independent precursor and fragment information Generate list of prospective compounds Quantify Targeted Data Analysis Compound databases nw-xic -RT - Mass error - Isotope patterns - Fragment ion data Quantitation of positives Benefits Utilise U-HPLC speed Precursors & Fragments in single injection Good selectivity it from UPLC & MS resolution, mass accuracy & stability, use of fragment ions Reduced false positives Required sensitivity for regulatory use & discovery of unknowns Works with complex matrices Screen & Quantify

21 Targeted Screening River Water MS E fragment ions 59 compounds targeted, 5 detected within tolerances MS E molecular ions Overview of all detected compounds in all samples

22 River Water Screening Codeine Detection M: +.4 mda M: mda M: +.1 mda M: -.1 mda MassFragment

23 Discovery & Identification of Discovery & Identification of Unknown Residues

24 Unknown Discovery and Identification Non-selective sample extraction Non-Targeted (Unbiased) Data Acquisition Acquire single comprehensive dataset with independent precursor and fragment information Non-Targeted Data Analysis Application Managers o Identify using spectral libraries o Compare o Detect t and identify transformation products Generate component list S List of detected known compounds Spectral deconvolution Apply application managers o Detect and identify markers of sample differentiation Elucidate structure of unknowns DISCOVERY o Apply structural elucidation tools o Confirm identity

25 Example Workflow Acquire single comprehensive dataset with independent precursor and fragment information DISCOVERY Spectral deconvolution Compare samples Use Acc Mass and isotope profile filters Non-Targeted Data Analysis Component List Detect Unknown Propose Elemental Composition 1 2 Search database for candidates Provide structure and fragment ion spectra to Massfragment Propose Candidate Structure Test Candidate Structure Confirm Candidate (Standard + MS/MS)

26 Non-Targeted Components Deconvoluting river water sample 1 deconvoluted non-targeted components Codeine detected in non-target mode

27 Non-Targeted Components Comparison with control sample 1 Unique components in each sample Unusual Chlorinated component 3 rd highest abundance

28 Non-Targeted Component Elucidating structure of unknown Unknown component RT 2.28min, m/z Elecomp and i-fit proposed C 6 H 13 O 4 PCl 3 as candidate

29 Non-Targeted Component Elucidating structure of unknown C 6 H 12 O 4 PCl 3 entered into Chemspider search ([M+H] + ) ChemSpider proposed a number of structures Tris(2-chloroethyl) Phosphate is a commonly used flame retardant and the top hit

30 Non-Targeted Component MassFragment and MS E MS E fragments m/z M = -.3 mda m/z M = -1.1 mda 4 Precursor m/z M = -.1 mda Unknown component in river water

31 Non-Targeted Component Isotope Model Comparison Isotope model based on proposed formula Original acquired mass spectrum ChemSpider result 211 Waters Corporation COMPANY CONFIDENTIAL 31

32 Non-Targeted Components Comparison with control sample 1 Another unusual compound not detected in the control

33 Non-Targeted Component Emerging g contaminants in river water Time Time Unknown component RT min, m/z Elecomp and i-fit ChemSpider proposed proposed C 15 H 13 N 2 O as Carbamazepine candidate 2

34 Non-Targeted Component MassFragment and MS E MS E fragments m/z M = -.3 Da MS/MS spectrum Precursor 4 1 m/z m/z M = +.3 Da m/z m/z Unknown component in river water Carbamazepine standard

35 Conclusions Compounds as diverse as the anticonvulsant mood stabilizing drug carbamazepine, the analgesic compound codeine and the flame retardant tris(2-chloroethyl) phosphate were discovered in the river water blank using this non-targeted structural elucidation workflow approach. The MS E functionality enables the acquisition of both low energy (precursor ion) and high energy (fragment ion) data in a single rapid screening run. MS E fragment ion data can be used to help with unequivocal identification of detected compounds. The compare functionality, elemental composition, and mass fragment strategies in the workflow provide powerful tools for screening, detection, and identification of true nontargeted species in environmental matrices. 211 Waters Corporation COMPANY CONFIDENTIAL 35

36 Many Thanks Riches E, 1 Morphet J, 1 Major H, 1 Keenan G, 2 Giela A, 2 Rosnack K, 3 1 Waters Corporation, Atlas Park, Simonsway, Manchester M22 5PP; eleanor_riches@waters.com 2 SASA, Roddinglaw Road, Edinburgh, Scotland EH12 9FJ; george.keenan@sasa.gsi.gov.uk 3 Waters Corporation, 34 Maple Street, Milford, MA, 1757; ken_rosnack@waters.com 211 Waters Corporation COMPANY CONFIDENTIAL 36

37 QUESTIONS? Chemical Analysis Business Operations Waters Corporation Milford MA

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System. Fast and Sensitive in vitro Metabolism Study of Rate and Routes of Clearance for Ritonavir using UPLC CUPLED with the Xevo QTof MS System Jose Castro-Perez, Kate Yu, John Shockcor, Henry Shion, Emma Marsden-Edwards,

More information

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications Ignatius J. Kass Senior Field Marketing Manager Pharmaceutical MS Challenges in Pharmaceutical Sample Analysis Quantitative

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS [ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,

More information

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Yoann Deceuninck 1, Emmanuelle Bichon 1, Paul Silcock 2, Fabrice Monteau

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS Ying Qing Yu Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F I T

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical

More information

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices

More information

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry Michael McCullagh, 1 Kieran Neeson, 2 and Antonietta Gledhill 1 Waters Corporation,

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

Small Molecule Science: Experimental designs for achieving ultra trace analysis

Small Molecule Science: Experimental designs for achieving ultra trace analysis Small Molecule Science: Experimental designs for achieving ultra trace analysis Michael P. Balogh Principal scientist Waters Corporation 211 Waters Corporation 1 www.cosmoscience.org The Society for Small

More information

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS Yun Wang Alelyunas, Henry Shion, Mark Wrona Waters Corporation, Milford, MA, USA APPLICATION BENEFITS mab LC-MS method which enables users to achieve highly sensitive bioanalysis of intact trastuzumab

More information

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism Elizabeth Want, 1 Stephen McDonald 2 1 Imperial College, London, UK 2 Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S UPLC /MS E was used to profile diagnostic metabolites in a

More information

SYNAPT G2-S High Definition MS (HDMS) System

SYNAPT G2-S High Definition MS (HDMS) System SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business

More information

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate

More information

COMBINED USE OF GC TOF MS AND UPLC-QTOF MS FOR INVESTIGATIVE ANALYSIS OF HONEYBEE POISONING

COMBINED USE OF GC TOF MS AND UPLC-QTOF MS FOR INVESTIGATIVE ANALYSIS OF HONEYBEE POISONING COMBINED USE OF GC TOF MS AND UPLC-QTOF MS FOR INVESTIGATIVE ANALYSIS OF HONEYBEE POISONING Tania Portolés 1, María Ibáñez 1, Juan V. Sancho 1, Francisco J. López 1, Félix Hernández 1, Antonietta Gledhill

More information

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Mark Ritchie and Evelyn Goh Waters Pacific Pte Ltd., Singapore A P P L I C AT ION B E N E F I T S Delivers a rapid 10-min MRM method

More information

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification 22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and

More information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F

More information

Ultra High Definition Optimizing all Analytical Dimensions

Ultra High Definition Optimizing all Analytical Dimensions Ultra High Definition Optimizing all Analytical Dimensions Sensitivity Dynamic Range Signal Response Linearity Separation Speed Peak Capacity Chromatogram Mass Spectrum Mass Accuracy Resolving Power Acquisition

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection Jane Cooper, 1 Baiba Cabovska 2 1 Waters Corporation, Wilmslow, UK 2 Waters

More information

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS Paul Silcock and Diana Uria Waters Corporation, Manchester, UK AIM To demonstrate the use of UPLC -TOF to characterize and detect

More information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Joanne Mather, Steve Cubbedge, Debadeep Bhattacharya, and Robert S. Plumb Waters Corporation, Milford, MA, U.S. A P P L

More information

Moving from targeted towards non-targeted approaches

Moving from targeted towards non-targeted approaches Gesundheitsdirektion Moving from targeted towards non-targeted approaches Anton Kaufmann Official Food Control Authority of the Canton of Zurich () Switzerland 2 Overview I From single residue to multi

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE

More information

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION Marian Twohig 1, Nicholas Ellor 1, Keith Worrall 2, Tim Jenkins 2, Gordon Kearney 2 1 Waters Corporation, 1 Cummings Center, Beverly, MA

More information

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD Claude R. Mallet Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S This

More information

Analysis of drugs of abuse in biological matrix using Time of Flight technology

Analysis of drugs of abuse in biological matrix using Time of Flight technology Analysis of drugs of abuse in biological matrix using Time of Flight technology Niclas Stephanson, PhD Department of Clinical Pharmacology Karolinska University Hospital Karolinska Institutet Stockholm,

More information

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE) Removal of Triton X- from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE) Jonathan P. Danaceau, Erin Chambers, and Kenneth J. Fountain Waters Corporation, 34 Maple Street, Milford, MA USA

More information

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1 Development of an SPE-LC/MS/MS Assay for the Simultaneous Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid in Support of Alzheimer s Research Dr. Erin E. Chambers Waters Corporation Presented

More information

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin

More information

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids Jeremy Netto, 1 Stephen Wong, 1 Federico Torta, 2 Pradeep Narayanaswamy, 2

More information

How to Use TOF and Q-TOF Mass Spectrometers

How to Use TOF and Q-TOF Mass Spectrometers How to Use TOF and Q-TOF Mass Spectrometers October 2011 What do TOF and Q-TOF offer? TOF Fast scanning of full spectrum High resolution full scan spectra Accurate mass measurements Q-TOF Fast scanning

More information

Increased Identification Coverage and Throughput for Complex Lipidomes

Increased Identification Coverage and Throughput for Complex Lipidomes Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive

More information

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Mark Benvenuti, Gareth Cleland, and Jennifer Burgess Waters Corporation, Milford, MA, USA

More information

Amadeo R. Fernández-Alba

Amadeo R. Fernández-Alba % of compounds % of compounds % of compounds % of compounds Amadeo R. Fernández-Alba LC-Orbitrap QExactive Focus Instrumental LOQ 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% %.1 mg/g.2 mg/g Tomato.5 mg/g ddms2 Target

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information

The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples

The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples WA20259 The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples Michael S. Young and Kevin M. Jenkins Waters Corporation, 34 Maple Street, Milford, MA 01757 Introduction

More information

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Larry T. Taylor, 1 Jinchuan Yang, 2 and Giorgis Isaac 2 1 Department of

More information

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University Mass Spectrometry Structure Elucidation Selective and Sensitive Detection Identification

More information

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary

More information

Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid

Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid Giorgis Isaac, Stephen McDonald, Giuseppe Astarita Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S

More information

A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species

A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species Bharathi Avula, 1 Kate Yu, 2 Yan-Hong Wang, 1 Jordan Blodgett, 2 Alan Millar, 2 and

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT ABSTRACT The traditional study of in vivo drug metabolism in plasma or urine samples is often complicated by the presence of many endogenous compounds. Several mass spectrometric techniques are often applied

More information

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System Mary E. Lame, Erin E. Chambers, Sukhdev S. Bangar, and Kenneth J. Fountain

More information

UPLC-HRMS: A tool for multi-residue veterinary drug methods

UPLC-HRMS: A tool for multi-residue veterinary drug methods AOAC, Paris, November 23-24, 2009 UPLC-HRMS: A tool for multi-residue veterinary drug methods Anton Kaufmann Official Food Control Authority of the Canton of Zurich (Kantonales Labor Zürich) The challenge

More information

Agilent s LC/MS Portfolio and Applications Examples

Agilent s LC/MS Portfolio and Applications Examples Agilent s LC/MS Portfolio and Applications Examples Sean Orlowicz LC/MS Product Specialist Agilent Technologies 31August Agilent s > 40 year heritage in mass spectrometry 1971, 5930A GC/MS 1971-2011 2005,

More information

for new contaminants at ultra trace level by using high resolution mass spectrometry

for new contaminants at ultra trace level by using high resolution mass spectrometry Non-targeted screening for new contaminants at ultra trace level by using high resolution mass spectrometry Dr Igor Fochi LSMS Product Specialist Thermo Fisher Scientific What is Environmental Analysis

More information

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK HIGH-THRUGHPUT REACTIVE METABLITE SCREEIG FR DICLFEAC BY UPLC AD XEV TQ MS WITH SCAWAVE Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford,

More information

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives Lieve Dillen Drug Safety Sciences Analytical Sciences, Non-regulated Bioanalysis Presentation outline

More information

PosterREPRINT SIMULTANEOUS QUANTIFICATION OF PSYCHOTHERAPEUTIC DRUGS IN HUMAN PLASMA BY TANDEM MASS SPECTROMETRY

PosterREPRINT SIMULTANEOUS QUANTIFICATION OF PSYCHOTHERAPEUTIC DRUGS IN HUMAN PLASMA BY TANDEM MASS SPECTROMETRY OVERVIEW A simple and rapid LC-MS/MS method has been developed which allows the simultaneous quantification of a panel of commonly prescribed psychotherapeutic drugs in human plasma and whole blood. INTRODUCTION

More information

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids Elizabeth J. Want, 1 Muireann Coen, Perrine Masson, Hector C. Keun, Jake T.M. Pearce, Michael D. Reily, Donald Robertson,

More information

Paul Silcock 1, Anna Karrman 2, and Bert van Bavel 2. Aim. Introduction. Sample preparation

Paul Silcock 1, Anna Karrman 2, and Bert van Bavel 2. Aim. Introduction. Sample preparation ADVANCING perfluorinated compound analysis USING SIMULTANEOUS matrix monitoring Paul Silcock 1, Anna Karrman 2, and Bert van Bavel 2 1 Waters Corporation, Manchester, UK 2 MTM Research Centre, Dept. of

More information

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden Noora Perkola Finnish Environment Institute Nordic MS Symposium November 9, 2011, Båstad, Sweden Artificial Sweeteners Used as additives in various food products to replace sugar 4 non-caloric sweeteners

More information

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data LECO Corporation; Saint Joseph, Michigan USA Key Words: Pegasus GC-HRT, GHB, Hair,

More information

PosterReprint OVERVIEW

PosterReprint OVERVIEW OVERVIEW A rapid multi-residue GC/MS method was developed for pesticides in foodstuffs. Plum extract was used as an example matrix. Analysis time was reduced from minutes to minutes. pesticides were analysed

More information

[ application note note ] ]

[ application note note ] ] [ application note note ] ] A NA LYSIS F SY IS F L AV N E S F RM A DIETA RY SU P P L EM ENT USING U P L C W IT H P DA AND S Q D E T EC T I N Antonietta Gledhill Waters Corporation, Manchester, UK. INT

More information

Phospholipid characterization by a TQ-MS data based identification scheme

Phospholipid characterization by a TQ-MS data based identification scheme P-CN1716E Phospholipid characterization by a TQ-MS data based identification scheme ASMS 2017 MP-406 Tsuyoshi Nakanishi 1, Masaki Yamada 1, Ningombam Sanjib Meitei 2, 3 1 Shimadzu Corporation, Kyoto, Japan,

More information

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation,

More information

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA Challenges of Polar Compound Analysis Routine LC/MS-based analyses usually rely on using reversed-phase column chemistries (e.g. C 18, C 8, C 4 ) in their LC methodology. However, one of the shortcomings

More information

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Emmanuelle Claude, Mark Towers, and Kieran Neeson Waters Corporation, Manchester,

More information

Sunil Kulkarni Product Specialist Agilent Technologies

Sunil Kulkarni Product Specialist Agilent Technologies Drug Residue Analysis by LC/MS methods Sunil Kulkarni Product Specialist Agilent Technologies Outline General Drug Residue information Veterinary drug residue Analysis by LC/MS QQQ and Q-TOF method Analytical

More information

Identification of Ginsenosides Using the SCIEX X500R QTOF System

Identification of Ginsenosides Using the SCIEX X500R QTOF System Identification of Ginsenosides Using the SCIEX X500R QTOF System Wang Sha, Cheng Haiyan, Liu Ting, Li Lijun, Jin Wenhai[Author] SCIEX, Pacific Applications Support Center (Beijing). China Background Ginseng

More information

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry Mass Spectrometry Laboratory AIMS Instrumentation & Sample Report Documentation AB Sciex QStar XL chemistry UNIVERSITY OF TORONTO AIMS Mass Spectrometry Laboratory Department of Chemistry, University of

More information

An Untargeted Exposure Study of Small Isolated Populations Using Atmospheric Gas Chromatography Coupled with High Resolution Mass Spectrometry

An Untargeted Exposure Study of Small Isolated Populations Using Atmospheric Gas Chromatography Coupled with High Resolution Mass Spectrometry An Untargeted Exposure Study of Small Isolated Populations Using Atmospheric Gas Chromatography Coupled with High Resolution Mass Spectrometry Pierre Dumas, 1 Lauren Mullin, 2 Paul Goulding, 3 and Adam

More information

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010 MASS SPECTROMETRY BASED METABOLOMICS Pavel Aronov ABRF2010 Metabolomics Research Group March 21, 2010 Types of Experiments in Metabolomics targeted non targeted Number of analyzed metabolites is limited

More information

NON TARGETED SEARCHING FOR FOOD

NON TARGETED SEARCHING FOR FOOD NON TARGETED SEARCHING FOR FOOD CONTAMINANTS USING ORBITRAP HIGH RESOLUTION MASS SPECTROMETRY Michal Godula 1, Adrian Charlton 2 and Klaus Mittendorf 1 1 Thermo Fisher Scientific, Dreieich, Germany 2 Food

More information

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection Christopher J. Hudalla, Stuart Chadwick, Fiona Liddicoat, Andrew Peck, and

More information

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis Michael S Young and Kim Van Tran Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Efficient, timesaving multiclass/ multiresidue methodology

More information

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS A RAPID AD SESITIVE AALYSIS METD OF SUDA RED I, II, III & IV I TOMATO SAUCE USIG ULTRA PERFORMACE LC MS/MS Choon Keow G, aomi TAAKA, Michelle KIM, Swee Lee YAP Waters Asia, Regional Technology Center,

More information

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Claude Mallet, 1 Jennifer Simeone, 2 Paul Rainville 3 1 Workflow Integration Group, Separations Technologies,

More information

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in uman Plasma Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, 34 Maple Street,

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

LC-Based Lipidomics Analysis on QTRAP Instruments

LC-Based Lipidomics Analysis on QTRAP Instruments LC-Based Lipidomics Analysis on QTRAP Instruments Junhua Wang and Paul RS Baker SCIEX LC-Based Lipidomics Analysis Topics Covered Lipid extraction techniques Hydrophilic Interaction Chromatography (HILIC)

More information

Michal Godula Thermo Fisher Scientific. The world leader in serving science

Michal Godula Thermo Fisher Scientific. The world leader in serving science Resolving the food authenticity challenges using advanced isotopic ratio and Thermo Scientific Orbitrap high resolution mass spectrometry tools in practice Michal Godula Thermo Fisher Scientific The world

More information

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES RPID ND SENSITIVE PLC/V/MS METD FR SIMVSTTIN ND LV S TT IN IN S P P RT F C L E NING V L I DT I N S T DIES Erin Chambers, Diane Diehl, and Jeff Mazzeo Waters Corporation, Milford, M, S BCKGRND tilizing

More information

Towards High Resolution MS in Regulated Bioanalysis

Towards High Resolution MS in Regulated Bioanalysis Towards High Resolution MS in Regulated Bioanalysis Benno Ingelse MSD 3 rd EB focus meeting June 12 th 13 th Brussels, Belgium Contributors Gary Adamson Ken Anderson Kevin Bateman Cynthia Chavez-Eng Inhou

More information

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms Erin E. Chambers and Kenneth J. Fountain Waters Corporation, Milford,

More information

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No. Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are

More information

Sue D Antonio Application Chemist Cedar Creek, TX

Sue D Antonio Application Chemist Cedar Creek, TX Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis

More information

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

LC-MS/MS Solutions for Comprehensive Cannabis Analysis MODERN CANNABIS LC-MS/MS ANALYSIS TOTAL SOLUTION LC-MS/MS Solutions for Comprehensive Cannabis Analysis PIONEERING YOUR ANALYTICAL TESTING REQUIREMENTS Your Partner for LC-MS/MS Solutions for Cannabis

More information

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for

More information

Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples

Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples Mark A. McDowall Pharmaceutical Discovery & Life Sciences Waters Corporation, Manchester, UK 2011 Waters

More information

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material

More information

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Food Safety Authors M. H. Blokland, P. W. Zoontjes, S. S. Sterk, and L. A. van Ginkel, National Institute of Public Health and

More information

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT. Objective The aim of the study presented is to determine the presence of target Gingkolides in Gingko biloba leaf extract. The data presented shows Gingkolides determined to be present in the extract analyzed.

More information

Profiling and Quantitation of Metabolomic Signatures for Breast Cancer Cell Progression

Profiling and Quantitation of Metabolomic Signatures for Breast Cancer Cell Progression Profiling and Quantitation of Metabolomic Signatures for Breast Cancer Cell Progression Henry Shion, 1 Irwin Kurland, 2 Sumanta Goswami, 2,3 David Kusin, 3 Haitao Lu, 2 Bhavapriya Vaitheesvaran, 2 John

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words

More information

[ APPLICATION NOTE ] A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research APPLICATION BENEFITS

[ APPLICATION NOTE ] A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research APPLICATION BENEFITS A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research Mary Lame, Caitlin Dunning, and Erin Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring

More information

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D

More information

Strengthening Results. Advanced Chromatography with Mass Detection

Strengthening Results. Advanced Chromatography with Mass Detection Strengthening Results Advanced Chromatography with Mass Detection UV Detection Why Not Use UV For Everything? Identification Difficult selectivity in complex matrices Sensitivity Need sufficient molar

More information

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS Kayleigh Arthur K.Arthur@lboro.ac.uk Introduction LC-MS is a highly used technique for untargeted profiling analyses

More information

Dienes Derivatization MaxSpec Kit

Dienes Derivatization MaxSpec Kit Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information