1 Basic principles of preparative HPLC Basically, preparative HPLC follows the same rules as analytical scale chromatography. However, there are important differences in the aims of the two techniques. In analytical HPLC chromatographers focus on peak shape, and resolution of all eluted analytes, whereas in preparative chromatography yield and purity of the final product, as well as cost-effectiveness of the method, are emphasized. throughput Typical relation between feed volume and resolution w w min demands on preparative separations 1 yield purity w w min = peak width = minimum peak width V 0 This chapter discusses the most important parameters, which have to be taken into account in preparative method development. Definition of the production rate includes information about the required purity of the isolated product. That is, the user has to define the minimum resolution of the product peak from neighbouring peaks. The parameters determining the resolution between two peaks are relative retention α (ratio of both k values), the plate number of the column and the k value (formulas see chapter Basic terms and definitions on page 173). The relative retention is determined by the chromatographic system, i.e. mobile and stationary phases. Proper choice of column and eluent will produce the required selectivity and resolution of the chromatographic system for the sample to be separated. In practice, one often has to use a non-optimal system, e.g. because of sample solubility or because of incompatibility of a chromatographically desirable eluent with the following work-up or application steps of the isolated product after chromatography. For a detailed discussion of the term resolution please refer to the paper by L.R. Snyder 1. For maximising throughput, preparative HPLC columns are often overloaded (for details concerning overload phenomena see below). Under these conditions the resolution depends on the sample mass and on the injection volume. With increasing feed volume V 0 the resolution remains almost constant, until from a certain value it decreases linearly with further increase of the feed volume (for details about volume overload see below). R R max 1 R = resolution R max = maximum resolution V 0 = feed volume V 0 61

2 Basic principles of preparative HPLC When speaking about the production rate of a preparative separation, the term loadability of the column should be considered, too. According to general understanding, this is the maximum sample size (with defined sample mass and volume) under which a column still provides optimum selectivity. The chemical literature contains several propositions for definition of the loadability 3 6. In practice, however, these theoretical approaches are seldom used, because the maximum injection size is determined empirically: one injects increasing amounts, until the peaks just touch. However, it should be noted, that for the same injection size the loadability for dilute samples is higher than for concentrated ones 7. The parameters which are important for the optimisation of the mass loadability of a column can be described by the following formula. Mass loadability of a column 2 M C 1 πr 2 d = lkda S C P l M = maximum sample mass C 1, C 2 = constants r = column radius l = column length K = partition coefficient d = packing density A S = adsorbent surface d P = particle diameter The significance of the individual parameters can be easily seen. However, two terms should be noted in detail: column length l and particle diameter d P. As can be seen from the term d P 2 /l, the mass loadability of the column decreases with increasing plate number (l/d P 2 is proportional to the plate number N). Experimentally, this relation can be easily shown with columns of different plate numbers. N The preceding diagram shows the dependence of the separation efficiency of two columns from the mass loading. The two columns were run under the same conditions, but with packings of different particle size (d P ) 8 If an increased loadability is required for a given separation efficiency, it is recommended to increase particle size and column length, the increase in column length being the square of the increase in particle diameter. This will produce a welcome side effect: the relative permeability of the column will also increase quadratically, and the pressure drop of the column will decrease quadratically as shown in the table below. Influence of particle size and column length on loadability and permeability for constant separation efficiency l [cm] d p [µm] rel. loadability rel. permeability As can be seen from the following formula, the volume loadability linearly depends on the dead volume of the column used, and otherwise it only depends on the k values of the components to be separated and on the separation efficiency of the column. Volume loadability of a column 3) 2 V L = V 0 ( α 1)k A ( 2+ k A + k B ) N V 0 = dead volume V L = maximum overload volume α = relative retention (k B /k A ) N = plate number k A,k B = capacity factors column 1 column 2 mass loading loadability column 1 loadability column 2 g (component i) g (adsorbent) 62

3 Basic principles of preparative HPLC In addition to the loadability of the column used for a preparative separation another consideration can be important for the optimisation of the production rate 9. The production rate is directly proportional to the column diameter, the linear flow velocity of the mobile phase, the concentration of the component to be isolated (unless under mass overload conditions) and the term [1/N H 0 /l] 1/2, where H 0 is the plate height of the column under ideal conditions, l is the column length, and N is the plate number required for separation of the desired product with the purity required. The following limiting cases can be distinguished: l < H 0 N: Here a negative value is generated under the square root with the result of a physically meaningless production rate: the plate number of the column is smaller than required. l = H 0 N: The column plate number is just sufficient for the separation. The corresponding column length is a critical value where the production rate is zero. l > H 0 N: Further increase of the column length results in increasing production rates. Production rate [mg/h] ,5 particle size [µm] 0 0 0,5 1 1, column length [m] Since in practice optimisation of the production rate of a desired substance often results in overload conditions of the column, we briefly wish to discuss the related phenomena. Typical cases, which can cause column overload conditions, are e.g. samples with low solubility in the mobile phase or injection of too large a sample volume, highly concentrated samples, samples which are dissolved in a solvent with much better solvation characteristics than the mobile phase. Here sample concentration at the column inlet can cause problems. When considering overload phenomena, one has to distinguish between concentration overload, volume overload and mass overload conditions. Concentration overload The concentration of the analytes in the injected sample solutions is increased, while the injection volume is kept constant. With increasing overload peaks are more and more distorted, with the peak shape approaching a triangle. Fronting as well as tailing can occur. Simultaneously, with increasing overload the peak maxima are shifted, in most cases towards the dead time. This type of overload is called concentration overload. A concentration overload is only possible, if the solubility of the analytes in the sample solution is large enough. Volume overload If the solubility of the analytes is low, overload can only be obtained if, for a given sample concentration, the injection volume is continuously increased. Increasing sample volume results in peak broadening, approaching a rectangular shape. However, peaks remain symmetrical and from a certain overload peak heights remain constant. This type of overload is called volume overload. A characteristic of volume overload is constant retention volumes of the peak fronts even under overload conditions 3. The rectangular peak shape obtained by volume overload is shown in the following chromatograms. The relation between column length and production rate can be seen in the diagram above, where typical values for production rates are plotted versus column length. The figure shows different curves for columns with different particle sizes and hence different separation efficiencies. It should be noted, that after a steep rise at relatively short column lengths the slope of these curves decreases drastically approaching a saturation value. This is reached when 1/N is much larger than H 0 /l. 63

4 Basic principles of preparative HPLC Volume overload is demonstrated for the separation of a 3- component mixture of benzene, naphthalene and anthracene and a 2-component mixture of naphthalene and anthracene. The masses of the solutes injected were kept constant in all cases. 3-component mixture 2-component mixture Transition from elution development towards frontal analysis caused by volume overload sample volume A 10 µl 0 µl A B C B C sample volume 1 µl sample volume 2 ml 3 ml sample volume 1 ml sample volume 2 ml A B C A B C sample volume 2 ml sample volume 4 ml sample volume 6 ml sample volume 3 ml sample volume 6 ml B+C A B C The constant retention volumes of the peak fronts combined with the rectangular peak shapes, however, allow a peak assignment with the aid of frontal analysis even for an otherwise insufficient resolution. When injecting such large volumes, certain precautions have to be taken when employing injection procedures with valve and sample loop. Improper injection can result in the concentration profile of the sample taking the form of a Poisson curve which will make frontal analysis difficult or impossible 3. For the decrease of separation efficiency under volume overload conditions one can make the following estimate: The plate heights will increase by about 20% when the sample volume is about 1.5% of the column void volume, and they will about double when the sample volume increases to about 3 3.5% 5. sample volume 16 ml A+B+C A A+B B+C C 64

5 Basic principles of preparative HPLC Mass overload If the injected sample mass (calculated from injection volume and concentration) exceeds a certain value, the local concentration of the sample in the column can be so large, that equilibration is no longer possible: this case is called mass overload. Mass overload is much more complex than volume overload and is based on three main effects 3 : Dispersion effects. The sample is distributed along the column by the mobile phase until it contacts sufficient adsorbent to permit equilibrium with the stationary phase. This phenomenon results in band spreading similar to volume overload. Deactivation of the adsorbent. In addition to dispersion effects a massive sample charge will occupy a significant portion of the stationary phase resulting in a changed effective polarity of the mobile phase compared to the stationary phase. This can cause reduced retention which will also affect components of the sample with lower concentration. Non-linear adsorption isotherms, caused by large sample concentrations, result in peak tailing. Thus, mass overload can be recognised by changed retention volumes of the peak fronts of all components of a mixture to be separated. Peak broadening and tailing will mainly affect the sample components which are present in excess relative to the column load capacity (see chromatograms on the left). Mass overload for the separation of benzene, naphthalene and anthracene B N A The figure shows mass overload for the separation of benzene, naphthalene and anthracene. The amount of benzene injected is increased from 180 µg via 8.1 mg to 16.9 mg, while the amounts of naphthalene and anthracene are kept constant. If the aim of a preparative separation is to obtain as much of the pure compound per time unit as possible, overload of the column will in most cases be necessary. In practice combinations of concentration and volume overload are most often used. With diluted samples volume overload will occur more often, while concentrated sample solutions will show a tendency towards concentration and mass overload. Often both effects are present and peaks approach the shape of a trapezoid. Concentration overload is to be preferred, because it allows separation of larger sample amounts. References: 1) L.R. Snyder, J. Chromatogr. Sci. 10 (1972) 200 and 369 2) A. Wehrli, U. Hermann and J. F. K. Huber, J. Chromatogr. 125 (1976) 59 3) R. P. W. Scott, P. Kucera, J. Chromatogr. 119 (1976) 467 4) L. R. Snyder, Anal. Chem. 39 (1967) 698 5) W. Beck, I. Halasz, Z. Anal. Chem. 291 (1978) 340 6) T. Roumeliotis, K. K. Unger, J. Chromatogr. 185 (1979) 445 7) J. J. De Stefano, H. C. Beachell, J. Chromatogr. Sci 10 (1972) 654 8) A. W. J. De Jong, H. Poppe, J. C. Kraak, J. Chromatogr. 209 (1981) 432 9) K. P. Hupe, H. H. Lauer, J. Chromatogr. 203 (1981) 41 10) V. R. Meyer, Praxis der Hochleistungs-Flüssigchromatographie, Otto Salle Verlag, Frankfurt, 7. Aufl., 1992 B B N A N A 65

6 Scale-up from analytical to preparative HPLC amount of adsorbent sample volume amount of analyte flow rate Scale-up factor } = f(id) However, overloading a column always means a considerable loss of separation efficiency. For this reason, overloading the chromatographic system must show sufficient resolution. Consequently, for optimising a preparative separation, the chromatographic selectivity has to be optimised under analytical conditions to reach a resolution as high as possible. The higher the selectivity for a given phase system, the more a column can be overloaded. For preparative separations under overload conditions stationary phases with larger mean particle sizes are usually sufficient. Prerequisite for a successful transfer from established analytical methods to the preparative scale are stationary phases with equal selectivity for both methods. However, heavy overload can also change the chromatographic selectivity relative to analytical conditions. For separation of larger amounts of a substance there are two general approaches: linear scale-up of the analytical system overloading the column In the case of linear scale-up the column length is kept constant and the column cross section is increased proportionally to the sample mass. Eluent flow and sample volume are adapted correspondingly. As in analytical HPLC, stationary phases with small particle sizes are used. The separation efficiency of the prep column is more or less the same compared with the analytical column. Peaks remain sharp and symmetrical. The procedure of linear scale-up is not very economical, since large columns and large amounts of eluents are required, and the substance yield is relatively low. For example, more than 5 kg stationary phase and l mobile phase are necessary to separate less than 1 g of a substance mixture in one run. For this reason linear scale-up alone is only used in exceptional cases, e.g. if for difficult separations the high separation efficiency is needed for the isolation of (in most cases small amounts of) substances with very high purity. A better way is overloading the column, since for a given yield less stationary phase and less eluent are required. This procedure allows injection and separation of amounts in the lower milligram range on an analytical HPLC column. For preparative separations on the gram or kilogram scale overloading is combined with a linear scale-up of the chromatographic system. Procedure for scale-up In general, an analytical chromatogram is used as a starting point for a preparative separation. It is necessary to find conditions, which separate the sample mixture isocratically with good resolution, since gradients are not recommended for preparative separations, because they require large efforts in every respect. If necessary, proper sample preparation may be required. The better the resolution in the analytical chromatogram, the larger the load on the preparative column can be. After optimisation of the separation on the analytical column the maximum sample amount for injection of a concentrated solution is determined empirically. In the simplest case overload is increased, until the peaks in the chromatogram of the separation just do not yet overlap, allowing isolation of the peaks and, after removal of the mobile phase, obtaining the pure substances with 100% yield. Undiluted solutions are not favourable. It is not recommended to dissolve the sample in a stronger solvent than the mobile phase. Since for preparative work in most cases larger volumes are injected, the solvent can severely interfere with the equilibrium in the column, even making reproducibility of the chromatographic system impossible. Solubility of the sample in the mobile phase has to be good, because otherwise the column may get plugged. 66

7 Scale-up from analytical to preparative HPLC The scale-up factor After optimisation of the analytical separation the preparative column is to be considered. Transfer from an analytical to a preparative separation is easiest, if both are packed with the same stationary phase (linear scale-up). A key for successful transfer of results gained for the analytical column to the preparative scale is the proper scale-up factor. If the analytical or the preparative factor is not listed in the table below, it can be calculated form the following formula: Now every parameter relevant for the separation has to be multiplied with the scale-up factor. This includes flow rate, sample volume, sample mass, and the IDs of the capillaries. It is important during scale-up to increase the inner diameters of the capillaries proportionally, since otherwise the back-pressure of the system can become to large. For our programme of capillary tubing for HPLC please see the chapter Accessories on p. 169) 2 L M p M p d = p a L a d a M L d a p = sample mass = column length = column diameter analytical column preparative column Scale-up factors and parameters for typical column dimensions Column dimensions [mm] 4 x 2 8 x 2 10 x 2 16 x 2 21 x 2 40 x 2.8 x 2 80 x 2 Particle sizes [µm] NUCLEOSIL NUCLEODUR 3, 5, 7, 10 3, 5 Linear scale-up factor Typical sample mass * [mg] Amount of packing / column [g ±20%] Typical flow rate [ml/min] * for RP material; the maximum amounts given here always depend on the separation problem and on the sample composition. In some cases even half of the amounts given can cause dramatic overload, in other cases the maximum amounts can still give acceptable separations. 67

8 columns for preparative HPLC As with our analytical columns, our preparative columns feature capillary connections with UNF inner threads ( 1 / 16 ), thus meeting today s standard in HPLC technology. They are manufactured from stainless steel and are packed with NUCLEOSIL or NUCLEODUR packings from our range of silicas for HPLC. All packed columns are individually tested and supplied with the corresponding test certificate. We offer three different types of preparative columns: Standard-Prep, VarioPrep and Ecoprep. are available in lengths of 125 to 0 mm and inner diameters of 10 mm, 21 mm and.8 mm. Standard-Prep guard columns are mm long and available with the same inner diameters. Thus for scale-up the user can choose from a range of about two orders of magnitude in column diameters from the analytical 4 mm ID columns up to the.8 mm ID prep columns. have been developed in order to allow compensation of the dead volume, which could result at the column inlet after some time of operation, without need for opening the column. This special column technology is available as columns with one adjustable end fitting at the column inlet and a fixed end fitting at the column end. On request, we can also supply columns with two adjustable end fittings, an option which may e.g. be useful for frequent use of backflushing techniques. are available with lengths of 125 and 2 mm and inner diameters of 10, 21, 32, 40 and 80 mm. VarioPrep guard columns are mm long and available with inner diameters of 10, 21 and 40 mm. are available with lengths of 30, 70, 125 and 2 mm. The column head is an enlarged version of the analytical EC columns (s. p. 137). The inner diameters are intermediate sizes of 8 and 16 mm. These columns are especially suited for SMB systems. Shorter columns (individually tested) and guard columns are available on request. On request, our preparative columns can also be custom-packed with other types of NUCLEOSIL packings as well as with NUCLEODUR silicas. In addition, they can be made in lengths other than those indicated in the tabulated summary on pages 69 to 72. Preparative columns different types of column end fittings 1 Standard-Prep column with 10 mm ID 2 Standard-Prep column with 21 mm ID 3 VarioPrep column with 21 mm ID 4 EcoPrep column with 16 mm ID EcoPrep columns 68

9 Preparative columns packed with NUCLEOSIL and NUCLEODUR Ordering information (choice of columns) * Length 30 mm 70 mm 125 mm 2 mm Guard columns mm Base deactivated RP phases NUCLEODUR C 18 Gravity, 5 µm Particle size 5 µm, pore size 110 Å; octadecyl phase, endcapped, 18% C; eluent in column acetonitrile / water 10 mm ID mm ID NUCLEOSIL C 18 HD Particle size 5 µm, pore size 100 Å; octadecyl phase, endcapped, monomeric coating, 20% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID mm ID mm ID NUCLEOSIL C 18 HD Particle size 7 µm, pore size 100 Å; octadecyl phase, endcapped, monomeric coating, 20% C; eluent in column acetonitrile / water 16 mm ID NUCLEOSIL PROTECT I Particle size 5 µm, pore size 100 Å; special RP phase, endcapped, monomeric coating, 11% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID * On request, all preparative columns are available with any NUCLEOSIL or NUCLEODUR packing. Each column is individually tested and supplied with test chromatogram and test conditions 69

10 Preparative columns packed with NUCLEOSIL and NUCLEODUR Ordering information (choice of columns) * Length 30 mm 70 mm 125 mm 2 mm Guard columns mm Standard octadecyl phases NUCLEODUR C 18 ec Particle size 5 µm, pore size 110 Å; octadecyl phase, endcapped, 17.5% C; eluent in column acetonitrile / water 10 mm ID mm ID NUCLEOSIL C 18 Particle size 5 µm, pore size 100 Å; octadecyl phase, endcapped, 15% C; eluent in column acetonitrile / water 10 mm ID mm ID NUCLEODUR C 18 ec Particle size 7 µm, pore size 110 Å; octadecyl phase, endcapped, 17.5% C; eluent in column acetonitrile / water 10 mm DI mm DI mm DI mm DI NUCLEOSIL C 18 Particle size 7 µm, pore size 100 Å; octadecyl phase, endcapped, 15% C; eluent in column acetonitrile / water 10 mm ID mm ID mm (2 ) ID mm ID mm ID mm ID mm ID mm ID NUCLEOSIL C 18 Particle size 10 µm, pore size 100 Å; octadecyl phase, endcapped, 15% C; eluent in column acetonitrile / water 16 mm ID NUCLEOSIL C 18 Particle size 7 µm, pore size 120 Å; octadecyl phase, endcapped, 11% C; eluent in column acetonitrile / water 10 mm ID * On request, all preparative columns are available with any NUCLEOSIL or NUCLEODUR packing. 70

11 Preparative columns packed with NUCLEOSIL Ordering information (choice of columns) * Length 30 mm 70 mm 125 mm 2 mm Guard columns mm NUCLEOSIL C 18 Particle size 7 µm, pore size 300 Å; octadecyl phase, endcapped, 6.5% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID mm ID Standard octyl phases NUCLEOSIL C 8 Particle size 7 µm, pore size 100 Å; octyl phase, not endcapped, 8.5% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID mm ID mm ID mm ID NUCLEOSIL C 8 Particle size 7 µm, pore size 300 Å; octyl phase, not endcapped, ~3% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID mm ID * On request, all preparative columns are available with any NUCLEOSIL or NUCLEODUR packing. 71

12 Preparative columns packed with NUCLEOSIL Ordering information (choice of columns) * Length 30 mm 70 mm 125 mm 2 mm Guard columns mm Standard butyl phases NUCLEOSIL C 4 Particle size 7 µm, pore size 120 Å; butyl phase, endcapped, eluent in column acetonitrile / water 10 mm ID NUCLEOSIL C 4 Particle size 7 µm, pore size 300 Å; butyl phase, endcapped, ~2% C; eluent in column acetonitrile / water 10 mm ID mm ID mm ID mm ID Standard phenyl phases NUCLEOSIL C 6 H 5 Particle size 7 µm, pore size 100 Å; phenyl phase, not endcapped, eluent in column acetonitrile / water 10 mm ID mm ID mm ID Unmodified silica NUCLEOSIL -7 Particle size 7 µm, pore size Å; unmodified, eluent in column n-heptane 10 mm ID mm ID 7122 NUCLEOSIL Particle size 7 µm, pore size 100 Å; unmodified, eluent in column n-heptane 21 mm ID mm ID mm ID mm ID mm ID * On request, all preparative columns are available with any NUCLEOSIL or NUCLEODUR packing. On request, are also available with two adjustable end fittings, with 80 mm ID or with different lengths. For preparative HPLC columns for special separation problems please see the following chapter Columns for special applications Each column is individually tested and supplied with test chromatogram and test conditions 72

Columns for HPLC. Columns for HPLC. Basic principles of preparative HPLC

Columns for HPLC. Columns for HPLC. Basic principles of preparative HPLC Basic principles of preparative HPLC The efficiency of HPLC for separation of one or several components from a complex mixture makes HPLC an important technique for preparative purifications. The difference

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

HPLC. Varian Dynamax Preparative HPLC Columns

HPLC. Varian Dynamax Preparative HPLC Columns HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations Technical Overview Introduction PL-SAX is a hydrophilic strong anion-exchange chromatographic

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012)

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012) July 2012 RITONAVIRI COMPRESSI RITONAVIR TABLETS Final text for addition to The International Pharmacopoeia (July 2012) This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications

More information

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) June 2010 TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) This monograph was adopted at the Forty-fourth WHO Expert Committee on Specifications for Pharmaceutical

More information

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent

More information

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract JJC Jordan Journal of Chemistry Vol. 4 No.4, 2009, pp. 357-365 Development and Validation of Analytical Method for Fluconazole and Fluconazole Related Compounds (A, B, and C) in Capsule Formulations by

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Method development and validation of tenofovir disoproxil fumerate and emtricitabine in combined tablet

More information

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE WORLD JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES Ramalakshmi et al. SJIF Impact Factor 6.647 Volume 7, Issue 2, 1010-1018 Research Article ISSN 2278 4357 METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(1):138-144 Simultaneous RP HPLC determination of Latanoprost

More information

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms Asian Journal of Chemistry Vol. 22, No. 7 (2010), 5067-5071 RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms A. LAKSHMANA RAO*, G. TARAKA RAMESH and J.V.L.N.S. RAO Department of Pharmaceutical

More information

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets Journal of PharmaSciTech 0; ():- Research Article Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets * Sayyed Hussain,

More information

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-Performance Normal Phase Partition Chromatography (1) Table of Contents

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-Performance Normal Phase Partition Chromatography (1) Table of Contents No. 055 SEPARATION REPORT Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-Performance Normal Phase Partition Chromatography (1) Table of Contents 1. Introduction 1 2. Elution

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1 Application Note Preparative Isolation of Piperine from Black Pepper Extracts Category Food analysis Matrix Pepper Extract Method analytical HPLC, preparative HPLC Keywords Pepper, quality control, purity

More information

Chromatography on Immobilized Artificial Membrane

Chromatography on Immobilized Artificial Membrane Chromatography on Immobilized Artificial Membrane Principles of measuring compounds affinity to phospholipids using immobilized artificial membrane chromatography Chromatography on Immobilized Artificial

More information

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory

More information

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION http://www.rasayanjournal.com Vol.4, No.3 (2011), 666-672 ISSN: 0974-1496 CODEN: RJCABP DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR IN BULK AND ITS PHARMACEUTICAL FORMULATION V.Kalyan Chakravarthy*

More information

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Method development of cytotoxic drugs selectivity IAC Seminar, 06.03.2015 Content Introduction Definition

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Flupyradifurone. HPLC Method

Flupyradifurone. HPLC Method HPLC Method CIPAC Collaboration Trial according to CIPAC Information Sheet No 308 by Alexandra Michel Crop Science Division Bayer Aktiengesellschaft Alfred-Nobel-Str. 50, Building 6820 40789 Monheim am

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM Int. J. Chem. Sci.: 6(3), 2008, 1576-1582 SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM B. NEELIMA, P. RAVI KUMAR, M. MURALI KRISHNA, V. HIMA

More information

Ergovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2

Ergovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2 Ergovaline C 29 35 5 5 MW: 533.619 CAS o.: 2873-38-3 [Summary of ergovaline] Ergovaline is a kind of ergot alkaloids produced by endophytes eotyphodium coenophialum and eotyphodium lolli, symbionts of

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION http://www.rasayanjournal.com Vol.4, No.1 (2011), 165-171 ISSN: 0974-1496 CODEN: RJCABP DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR AND ITS PHARMACEUTICAL FORMULATION V. Kalyana Chakravarthy * and

More information

EMTRICITABINE AND TENOFOVIR TABLETS

EMTRICITABINE AND TENOFOVIR TABLETS September 2010 RESTRICTED EMTRICITABINE AND TENOFOVIR TABLETS Draft proposal for The International Pharmacopoeia (September2010) REVISED DRAFT FOR COMMENT This document was provided by a quality control

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015) August 2015 Document for comment 1 2 3 4 5 CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA (AUGUST 2015) DRAFT FOR COMMENT 6 Should you have any comments

More information

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS September 2010 RESTRICTED DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS (August 2010) DRAFT FOR COMMENT This document was provided by a quality control

More information

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol 3-Acetyldeoxynivalenol 15-Acetyldeoxynivalenol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of trichothecene mycotoxin by gas chromatography [Feed Analysis Standards, Chapter

More information

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS Research Article N. Bala Krishna, IJPRBS, 2013; Volume 2(1): 63-77 ISSN: 2277-8713 IJPRBS N.BALAA KRISHNA, Dr. M.V.V NAGESWARA REDDY IJPRBS-QR CODE PAPER-QR CODE DEVELOPMENT OF NEW ANALYTICAL TECHNIQUES

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: Research Article CODEN: AJPAD7 ISSN: 2321-0923 Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: www.ajpamc.com ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF GEFITINIB

More information

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method

More information

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms Asian Journal of Chemistry Vol. 21, No. 2 (2009), 829-833 Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms B.V.V.S. JAGADEESH, S. SATYANARAYANA RAJU, V.JAYATHIRTHA RAO and J.V.L.N.

More information

Purification - Flash Chromatography

Purification - Flash Chromatography SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

Kromasil The way to peak performance in liquid chromatography

Kromasil The way to peak performance in liquid chromatography Kromasil The way to peak performance in liquid chromatography Kromasil product catalogue Kromasil is offered in a wide assortment of columns and in bulk amounts from parts of kilograms to metric tons.

More information

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Neosolaniol. [Methods listed in the Feed Analysis Standards] Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]

More information

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (11):236-242 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

SUMMARY, CONCLUSION & RECOMMENDATIONS

SUMMARY, CONCLUSION & RECOMMENDATIONS 196 Chapter-5 SUMMARY, CONCLUSION & RECOMMENDATIONS 197 CHAPTER 5 5.1 Summary, Conclusion and Recommendations Summary and Conclusion are drawn based on the work carried out by the author on development

More information

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079 Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

14 Separation of the Phosphatidylcholines Using Reverse Phase HPLC

14 Separation of the Phosphatidylcholines Using Reverse Phase HPLC 14 Separation of the Phosphatidylcholines Using Reverse Phase HPLC 14.1 Learning Objective This laboratory has 2 goals, (1) to learn more of membrane lipid structures by working with phosphatidylcholines

More information

PROPOSAL FOR REVISION OF MONOGRAPH PUBLISHED IN The International Pharmacopoeia: REVISION OF ph test ABACAVIR ORAL SOLUTION (JULY 2012)

PROPOSAL FOR REVISION OF MONOGRAPH PUBLISHED IN The International Pharmacopoeia: REVISION OF ph test ABACAVIR ORAL SOLUTION (JULY 2012) July 2012 RESTRICTED PROPOSAL FOR REVISION OF MONOGRAPH PUBLISHED IN The International Pharmacopoeia: REVISION OF ph test ABACAVIR ORAL SOLUTION (JULY 2012) PROPOSED REVISION FOR COMMENT The background

More information

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD 170 Original Article SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD *Lakshmana Rao A, 1 Bhaskara Raju V *V.V. Institute of Pharmaceutical Sciences, Gudlavalleru,

More information

CORESTA RECOMMENDED METHOD N 8

CORESTA RECOMMENDED METHOD N 8 CORESTA RECOMMENDED METHOD N 8 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS (August 1991) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

Columns for HPLC. Columns for HPLC

Columns for HPLC. Columns for HPLC In this chapter we describe analytical HPLC columns with our NUCLEOSIL silica phases. Silica as well as polymerbased phases for special separation problems are described in the chapter Columns for special

More information

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006)

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006) September 2006 RESTRICTED ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006) This document was provided by a contracted quality control laboratory.

More information

Fig.1. Denatonium benzoate (DB) chemical structure

Fig.1. Denatonium benzoate (DB) chemical structure ILIADE code 280 CLEN Method Determination of Denatonium Benzoate in Alcoholic Products by HPLC-UV 1 Scope The purpose of this method is verification of fulfilment of the legislative requirements on denatured

More information

ARTENIMOLUM ARTENIMOL. Adopted revised text for addition to The International Pharmacopoeia

ARTENIMOLUM ARTENIMOL. Adopted revised text for addition to The International Pharmacopoeia February 2012 ARTENIMOLUM ARTENIMOL Adopted revised text for addition to The International Pharmacopoeia This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications for Pharmaceutical

More information

Thermo Scientific Hypersil BDS Columns

Thermo Scientific Hypersil BDS Columns Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific Thermo Scientific Hypersil BDS

More information

you-try-it-02.xlsx Step-by-Step Guide ver. 8/26/2009

you-try-it-02.xlsx Step-by-Step Guide ver. 8/26/2009 you-try-it-02.xlsx Step-by-Step Guide ver. 8/26/2009 Abstract This document provides step-by-step instructions for the Excel workbook you-try-it-02.xlsx (Excel 2007). The worksheets contain data for practice

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

Studies on Stationary Phase Selectivity for Solid-Core Particles

Studies on Stationary Phase Selectivity for Solid-Core Particles Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com

More information

A New Dimension in Preparative HPLC

A New Dimension in Preparative HPLC New Dimension in Preparative HPL... we Meet your Needs NULEODUR HTec 6 - key features: reliable and durable standard RP phase for up-scaling to preparative scale, suited for L/MS high loadability and excellent

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available ACE HILIC UHPLC and HPLC s For Reproducible Polar Analyte Separations Three HILIC Chemistries Available ACE HILIC s What is HILIC? Hydrophilic Interaction Liquid Chromatography (HILIC) was first described

More information

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras) C 19 H 30 N 5 O 10 P. C 4 H 4 O 4 Relative molecular mass. 635.5. Chemical names. bis(1-methylethyl) 5-{[(1R)-2-(6-amino-9H-purin-9-yl)-1-methylethoxy]methyl}-5-oxo-2,4,6,8-tetraoxa-5-λ 5 - phosphanonanedioate

More information

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK

More information

Available online at Scholars Research Library

Available online at  Scholars Research Library Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2015, 7 (3):157-161 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms OPEN ACCESS Eurasian Journal of Analytical Chemistry ISSN: 1306-3057 2017 12(2):31-44 DOI 10.12973/ejac.2017.00152a A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide

More information

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2011, 8(3), 1212-1217 Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 11(4), 2013, 1607-1614 ISSN 0972-768X www.sadgurupublications.com DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

More information

IDENTIFICATION AND CONTROLOFRESIDUALSOLVENTS Identification and control of residual solvents EUROPEAN PHARMACOPOEIA 6.

IDENTIFICATION AND CONTROLOFRESIDUALSOLVENTS Identification and control of residual solvents EUROPEAN PHARMACOPOEIA 6. EUROPEAN PHARMACOPOEIA 6.0 2.4.24. Identification and control of residual solvents paper and wash each filter with 3 quantities, each of 15 ml, of methylenechlorider.placethecombinedfiltrateand washings

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Eric S. Grumbach,, Diane M. Diehl and Jeffrey R. Mazzeo 2003 Waters Corp. Outline Introduction HILIC Definition

More information

Preparative HPLC columns Eurospher II for semipreparative and preparative HPLC

Preparative HPLC columns Eurospher II for semipreparative and preparative HPLC Preparative HPLC columns Eurospher II for semipreparative and preparative HPLC Preparative column hardware with axial compression -> Longevity Wide range of modifications available -> Flexibility Extensive

More information

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE Int. J. Chem. Sci.: 6(1), 2008, 441-446 A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE S. APPALA RAJU, ARVIND B. KARADI and SHOBHA MANJUNATH HKES s College of Pharmacy,

More information

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences CODEN (USA)-IJPRUR, e-issn: 2348-6465 International Journal of Pharma Research and Health Sciences Available online at www.pharmahealthsciences.net Original Article Simultaneous Determination of Salbutamol

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Development and validation of related substances method for Varenicline and its impurities

Development and validation of related substances method for Varenicline and its impurities Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (1):304-309 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form S. LAVANYA* 1, SK. MANSURA BEGUM 1, K. NAGAMALLESWARA RAO 2, K. GAYATHRI DEVI 3 Department of pharmaceutical

More information

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 19 Infinity LC system Application Note Food Authors Standard solution Gerd Vanhoenacker, Frank David, Pat Sandra Research

More information