Join the mass movement towards mass spectrometry
|
|
- Ruby Bell
- 10 months ago
- Views:
Transcription
1 Join the mass movement towards mass spectrometry Thermo Scientific ISQ EC single quadrupole mass spectrometer
2 Embrace the power of mass spectrometry Achieving a comprehensive understanding of the samples you analyze is always a challenge. At Thermo Fisher Scientific, we believe the easier we can make the journey from sample to knowledge, the more information you will have to succeed with your analyses. Despite the benefits of incorporating mass spectrometry (MS) into your analyses, we know MS can seem complex. That is why we designed the Thermo Scientific ISQ EC single quadrupole mass spectrometer with ease of use in mind. The ISQ EC mass spectrometer not only seamlessly integrates with your ion chromatograph (IC) or liquid chromatograph (LC), but also sets new standards for user friendliness. Gain greater insights from your sample Coupling ion or liquid chromatography to mass spectrometry (MS), allows you to gain greater insights from your samples. Adding MS gives you: Higher sensitivity and more accurate quantitation Chromatographic peak mass confirmation, reducing the likelihood of false negatives and positives
3 Resolve complexity Analyze simple and complex matrices with confidence based on the superior robustness of the ISQ EC mass spectrometer. This single quadrupole MS offers: Improved resolution of analytes in complex matrices Identification of co-eluting peaks Easily master MS The seamless integration of the ISQ EC mass spectrometer with your IC or LC system allows you to focus on successfully using the system with: Integrated tools to to help you quickly learn the MS system Thermo Scientific Chromeleon Chromatography Data System (CDS) software for analysis, including embedded control of the ISQ EC mass spectrometer
4 Gain greater insights from your sample The power of MS enhances your chromatography analyses with higher sensitivity and improved selectivity for analytes of interest. The ISQ EC MS achieves limits of detection (LOD) in the single-digit-parts-per-billion (ppb) range. For analyses requiring peak confirmation, the ISQ EC MS provides mass-to-charge (m/z) confirmation for separated compounds to give you confidence in your results. Ion Chromatography Mass Spectrometry (IC-MS) Counts-min Counts-min µs-min ISQ EC MS, SIM ISQ EC MS, SIM Suppressed Conductivity Perchlorate, m/z 99 Perchlorate, m/z 11 Perchlorate? 6.7 Minutes 16 Intetensity (counts) Response (µs) , 5 25, 3, 35, Suppressed Conductivity Detection Pyruvate SIM 87 ISQ EC RT: pyruvate Succinate SIM 117 ISQ EC Malate SIM 133 ISQ EC Citrate SIM 191 ISQ EC RT: Succinate/Malate RT: pyruvate - Area: RT: Succinate - Area: RT: Malate - Area: 4218 RT: Citrate - Area: RT: Citrate Better sensitivity Coelution resolved in the MS dimension Better peak shape = better auto quantitation 2 4 Minutes The ISQ EC mass spectrometer offers improved low-mass sensitivity for detecting perchlorate in municipal drinking water. This sensitivity is not possible using IC with conductivity detection (CD) alone. Additionally, no organic solvent make-up is required. Compared to IC with conductivity detection alone, the ISQ EC MS provides better selectivity by resolving co-eluting peaks using mass-to-charge (m/z) ratio. In this example, succinate (m/z 117) and malate (m/z 133) peaks are co-eluting in an animal feed sample. These peaks are resolved in single ion monitoring (SIM) mode. 4
5 Liquid Chromatography Mass Spectrometry (LC-MS) Base Peak Chromatogram Emtricitabin Tenofovir disoproxil Intensity (counts * min) Adenine Tenofovir SIM m/z SIM m/z Minutes SIM m/z Full Scan 12 6 m/z SIM 52.2 m/z When detecting impurities for both routine and demanding pharmaceutical assays, MS provides reliable and robust quantification that complements traditional UV/Vis data. The ISQ EC MS can perform targeted and untargeted impurity profiling at the same time by employing Full Scan and SIM scans in the same run. This will ensure you do not miss a single peak. 5
6 Resolve complexity The ISQ EC mass spectrometer enables the analysis of a variety of complex sample matrices with unparalleled robustness. Reserpine Peak Area Robustness Peak Area Total RSD = 3.95%, 1 ppb, 1 pg on-column Between days 2 Sprayer needle change in the MS interface Injection Number The ISQ EC MS demonstrates reliable day-to-day, low-concentration reserpine peak area reproducibility, even while simultaneously performing routine maintenance. The ISQ EC features an all new orthogonal ion source specifically designed to address challenging sample matrices. The ion source provides longer, uninterrupted operation by saving time spent on maintenance.
7 Easily master MS The faster you develop your MS skills, the closer you move to expanding your sample knowledge. With the ISQ EC mass spectrometer, both novice and advanced users can easily master MS. Master MS Quickly access expert experiment-based knowledge built into the ISQ EC MS interface to obtain quality results fast. This interface was designed with unique algorithms and two modes. Easy Mode focuses your MS analysis using basic chemical parameters. Advanced Mode provides customizable parameters to enhance the quality of your results (e.g., sensitivity, peak confirmation, robustness). The intuitive ion source technology tool, incorporated into Easy Mode, helps you select optimal MS conditions based on three parameters. Gain more time for data analysis The first step to better understanding your sample is to analyze and report your IC-MS and/or LC-MS data. The Chromeleon CDS software simplifies this process with embedded control of the ISQ EC MS system. The software is not only easy to use, but also regulatory compliant. Step 1. Select your eworkflow and instrument Step 2. Create your sample list In addition: Quickly access detailed method information from the Thermo Scientific AppsLab Library of Analytical Applications, an online repository The Thermo Scientific Chromeleon XPS Open Access user interface enhances your user experience with simple, walk-up workflows Step 4. Get your custom analysis report, either printed or via Step 3. Submit your sequence An Autotune feature automates instrument calibration. Moreover, the Autotune can be scheduled as part of your workflow, at any time and from any place 7
8 Your trusted MS partner Thermo Fisher Scientific offers a comprehensive portfolio of mass spectrometry instruments to help you solve complex analytical challenges. Choose from our single quadrupole, triple quadrupole and high resolution accurate mass (HRAM) hybrid quadrupole-orbitrap MS instruments. We also provide a single point of contact for application, technical and integrated lab service support. Let our expertise complement yours along the journey from sample to knowledge. Thermo Scientific Orbitrap Fusion Tribrid Mass Spectrometer Thermo Scientific Q Exactive Hybrid Quadrupole-Orbitrap Mass Spectrometer Thermo Scientific TSQ Altis Triple Quadrupole Mass Spectrometer Thermo Scientific TSQ Quantis Triple Quadrupole Mass Spectrometer ISQ EC Single Quadrupole Mass Spectrometer Find out more at thermofisher.com/isqec 217 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. BR72397-EN 617S
LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS
LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling
Increased Identification Coverage and Throughput for Complex Lipidomes
Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive
The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides
The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides Mohammed Abrar Unilabs York Bioanalytical Solutions Outline Introduction Why LC-MS/MS? Limitations of
High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine
High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,
GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants
GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS
Thermo Scientific LipidSearch Software for Lipidomics Workflows Automated Identification and Relative of Lipids by LC/MS The promise of lipidomics Lipidomics is a new field of study crucial for understanding
IC-MS Environmental Applications - Water Testing. Application Notebook
IC-MS Environmental Applications - Water Testing Application Notebook Table of Contents Environmental Sample Using IC-MS 3 Environmental Applications: Water Testing Acrylamide in Water 4 Trace Urea in
Made For Routine Food, Environment, and Forensic Testing
Made For Routine Food, Environment, and Forensic Testing The X500R QTOF System Powered by SCIEX OS High resolution mass spec, in perfect balance It s Time You Were Heard For far too long you ve had to
Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition
Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble
Identification of Ginsenosides Using the SCIEX X500R QTOF System
Identification of Ginsenosides Using the SCIEX X500R QTOF System Wang Sha, Cheng Haiyan, Liu Ting, Li Lijun, Jin Wenhai[Author] SCIEX, Pacific Applications Support Center (Beijing). China Background Ginseng
New Methodologies for POPs Analysis using Orbitrap GC-MS in Official Food Control
New Methodologies for POPs Analysis using Orbitrap GC-MS in Official Food Control Dr. Nuria Cortés-Francisco Servei de Química Laboratori Agència Salut Pública Barcelona Vancouver, August 22 nd, 217 Summary
Sample Concentration and Analysis of Human Hormones in Drinking Water
Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in
A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.
A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin
LC-MS/MS Solutions for Comprehensive Cannabis Analysis
MODERN CANNABIS LC-MS/MS ANALYSIS TOTAL SOLUTION LC-MS/MS Solutions for Comprehensive Cannabis Analysis PIONEERING YOUR ANALYTICAL TESTING REQUIREMENTS Your Partner for LC-MS/MS Solutions for Cannabis
Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA
An Ultra High Resolution Glycan Column for Isomeric Separation and the Structural Identification of Labeled N-Glycans from Proteins Including Antibodies Udayanath Aich, 1 Julian Saba, 2 Rosa Viner, 2 Shanhua
Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition
PO-CON1321E Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition ASMS 213 TP 71 Jie Xing 1, Yin Ling Chew*
SeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention
SeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D
Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs
Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs Eric Niederkofler, 1 Dobrin Nedelkov, 1 Urban Kiernan, 1 David Phillips, 1 Kemmons Tubbs, 1 Scott Peterman, 2 Bryan Krastins,
LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for
POSTER NOTE 64921 LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for Research Use LC-MS/MS quantitative analysis of Poly Rory M Doyle*, Thermo Scientific, Inc,
Detection of aneuploidy in a single cell using the Ion ReproSeq PGS View Kit
APPLICATION NOTE Ion PGM System Detection of aneuploidy in a single cell using the Ion ReproSeq PGS View Kit Key findings The Ion PGM System, in concert with the Ion ReproSeq PGS View Kit and Ion Reporter
Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research
TECHNICAL NOTE 64913 Valium (diazepam) structure Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research Authors Claudio De Nardi,
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the LCMS-8040 provides higher multiple reaction
Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS
Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm
SYNAPT G2-S High Definition MS (HDMS) System
SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business
Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water
Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water Richard F. Jack, 1 Jinshui Che, 2 Lipika Basumallick, 1 and Jeffrey Rohrer 1 1 Thermo Fisher Scientific, Sunnyvale, CA, USA;
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.
Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS Product Overview Introduction The determination of multiple trace elements in high-matrix
Mercury Speciation Determinations in Asian Dietary Supplements
Mercury Speciation Determinations in Asian Dietary Supplements Terri Christison, Deepali Mohindra, Frank Hoefler, and Linda Lopez, Thermo Fisher Scientific, Sunnyvale, California, USA Overview Purpose:
A Fully Integrated Workflow for LC-MS/MS Analysis of Labeled and Native N-Linked Glycans Released From Proteins
A Fully Integrated Workflow for LC-MS/MS Analysis of Labeled and Native N-Linked Glycans Released From Proteins Udayanath Aich, 1 Julian Saba, 2 Xiaodong Liu, 1 Srinivasa Rao, 1 Yury Agroskin, 1 and Chris
2D-LC as an Automated Desalting Tool for MSD Analysis
2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja
Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research
Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION
Author. Introduction. Abstract
Simultaneous Measurement of Sirolimus and Tacrolimus Concentrations in Blood by Semi-Automated Extraction and Liquid Chromatography-Electrospray Ionization Mass Spectrometry Application Author Gary L.
Impurity Profiling of Carbamazepine by HPLC/UV
Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis
Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors
Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification,
Separation and Quantitation of Oxysterol Compounds Using LC-MS/MS. Liquid Chromatography Mass Spectrometry SSI-LCMS-082
Liquid Chromatography Mass Spectrometry SSI-LCMS-082 Separation and Quantitation of Oxysterol Compounds Using LC-MS/MS Liquid Chromatograph Mass Spectrometer LCMS-8060 Summary: A mixture of 16 oxysterols
Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases
APPLICATION NOTE Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases No. 21557 Aaron L. Lamb Thermo Fisher Scientific,
Characterization of an Unknown Compound Using the LTQ Orbitrap
Characterization of an Unknown Compound Using the LTQ rbitrap Donald Daley, Russell Scammell, Argenta Discovery Limited, 8/9 Spire Green Centre, Flex Meadow, Harlow, Essex, CM19 5TR, UK bjectives unknown
SCIEX Vitamin D 200M Assay for the Topaz System
The First FDA-Cleared LC-MS/MS Assay for Vitamin D SCIEX Vitamin D 200M Assay for the Topaz System The first FDA-cleared LC-MS/MS assay for Vitamin D Vitamin D is an important building block for human
Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS. No. GCMS No. SSI-GCMS-1501
Gas Chromatograph Mass Spectrometer No. GCMS-1501 Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS Shilpi Chopra, Ph.D., Laura Chambers Introduction Cocaine (CAS # 50-36-2), a white crystalline
Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection
Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D
An Introduction and Overview on Comprehensive Two-Dimensional Gas Chromatography (GCxGC): New Opportunities for Unresolved Complex Mixtures
An Introduction and Overview on Comprehensive Two-Dimensional Gas Chromatography (GCxGC): New Opportunities for Unresolved Complex Mixtures Daniela Cavagnino GC Product Manager Thermo Fisher Scientific,
ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS
ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS Anton Kaufmann Official Food Control Authority of the Canton of Zurich (Kantonales Labor Zürich) Switzerland
IntelliSpace Breast. Mammography solutions. Manage your breast review environment
IntelliSpace Breast Mammography solutions Manage your breast review environment Manage multiple breast images from a single workspace Now there is a fast, easy way to review, analyze, and diagnose the
[Application Note] TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY
TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY Camille Chatenay, 1,2 Fabien Bévalot, 1,2 Cyril Mounier, 1 Jean Michel Prévosto 1 1 Hôpital d Instruction des Armées Desgenettes,
BRAINLAB ELEMENTS RADIOTHERAPY PLANNING
BRAINLAB ELEMENTS RADIOTHERAPY PLANNING BUILD REACH AND RICHNESS BRAINLAB ELEMENTS Medical technology just got a whole lot easier and innovation is within reach with pre-planning software apps by Brainlab.
A new way of thinking. Philips Sparq critical care ultrasound system
A new way of thinking Philips Sparq critical care ultrasound system Introducing Philips Sparq Breakthrough technology should not make your life more complex. Quite the opposite. It should remove the complexities
Xiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction
Comparison of Non-derivatization and Derivatization Tandem Mass Spectrometry Methods for Analysis of Amino Acids, Acylcarnitines, and Succinylacetone in Dried Blood Spots Xiaolei Xie, Marta Kozak Thermo
Vitamin D3 and related compounds by ESI and APCI
Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate
Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products
High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C.
Determination of red blood cell fatty acid profiles in clinical research
Application Note Clinical Research Determination of red blood cell fatty acid profiles in clinical research Chemical ionization gas chromatography tandem mass spectrometry Authors Yvonne Schober 1, Hans
CLINITEK Novus Automated Urine Chemistry Analyzer
CLINITEK, Atlas, Novus, Status+, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks are properties of their respective owners. Product
3Shape X1 Scanning redefined
3Shape X1 Scanning redefined Why choose the X1 Give your patients a great experience No head fixation and sleek design create a comfortable scanning experience for your patient High image quality low dose
Determination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography
Application Note 8 Determination of Ethyl Sulfate Impurity in INTRODUCTION Indinavir sulfate is a specific and potent inhibitor of HIV- protease and is widely used in the treatment of AIDS. Indinavir sulfate
Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS
APPLICATION NOTE Mass Spectrometry Author: Avinash Dalmia PerkinElmer, Inc. Shelton, CT USA Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ
Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA
Fast Determination of Lactose and Lactulose in Dairy Products Using a 4 μm Particle Column and High-Performance Anion-Exchange Chromatography with Carl Fisher, Terri Christison, Hua Yang, Monika Verma,
CLARITY, PURE & bk3500 SIMPLE
CLARITY, PURE & bk3500 SIMPLE 4 chamber adult heart 5P1 transducer Early intrauterine pregnancy 9C2 transducer Jugular vein and carotid artery Vector Flow Imaging * 14L3 transducer Color Doppler demonstrating
INTRAORAL SCANNER TRANSFORMING CREATIVITY
INTRAORAL SCANNER TRANSFORMING CREATIVITY COMING SOON! POWDER-FREE SCANNING* Increased efficiency, accuracy, and comfort for your patient. Gesture control module for infection control INTRAORAL SCANNER
Quantification with Proteome Discoverer. Bernard Delanghe
Quantification with Proteome Discoverer Bernard Delanghe Overview: Which approach to use? Proteome Discoverer Quantification Method What When to use Metabolic labeling SILAC Cell culture systems Small
LC-MS Analysis of Amino Acids on a Novel Mixed-Mode HPLC Column
Liquid Chromatography Mass Spectrometry SSI-LCMS-022 LC-MS Analysis of Amino Acids on a ovel Mixed-Mode PLC Column LCMS-8040 Background There are four established methods for analyzing amino acids: prelabeled,
Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis
Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS
Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC
Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Application Note Environmental Author Melanie Metzlaff Agilent Technologies, Inc. Waldbronn, Germany Abstract
Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system
Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 641 Triple Quadrupole LC/MS system Application Note Clinical Research Author Siji Joseph Agilent Technologies Bangalore, India
Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples
Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples Application Note Forensic Toxicology Authors Joe Crifasi Saint Louis University Forensic Toxicology Laboratory Saint Louis, MO, USA Ron
Tandem mass spectrometry analysis of prostaglandins and isoprostanes
Tandem mass spectrometry analysis of prostaglandins and isoprostanes Jeevan Prasain jprasain@uab.edu 6-2612 verview Introduction to PGs and their synthesis Mass spectrometry characterization of PGs and
PIF: Precursor Ion Fingerprinting Searching for a Structurally Diagnostic Fragment Using Combined Targeted and Data Dependent MS n
Application Note: 441 PIF: Precursor Ion Fingerprinting Searching for a Structurally Diagnostic Fragment Using Combined Targeted and Data Dependent MS n Julie A. Horner, Rohan A. Thakur, Thermo Fisher
Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE. Take rugged reliability to challenging conditions.
Vivid T8 Ultrasound Cardiac and shared services. Together like never before from GE. Vivid cardiac. Shared services. Paired for excellent performance. In the Vivid T8, we ve taken the established cardiac
Rapid and Robust Detection of THC and Its Metabolites in Blood
Rapid and Robust Detection of THC and Its Metabolites in Blood Application Note Forensics/Doping Control Author Stephan Baumann Agilent Technologies, Inc. Santa Clara CA 95051 USA Abstract A robust method
Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform
Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform Abstract Targeted proteomics for biomarker verification/validation
Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis
Application Note AN890 Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Page Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Prior to LC/MS-MS
A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis
APPLICATION NOTE Cell-Free DNA Isolation Kit A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis Abstract Circulating cell-free DNA (cfdna) has been shown
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Target Analses in Parallel Reaction Monitoring Mode (PRM) Skline Webinar Januar 13, 2015 Bruno Domon, PhD Head Luxembourg Clinical Proteomics Center Invited Professor Universit of Luxembourg INTRODUCTION
Clinically focused workflow with unique ability to integrate fmri, DTI, fiber tracks and perfusion in a single, multi-layered 3D rendering
Clinically focused workflow with unique ability to integrate fmri, DTI, fiber tracks and perfusion in a single, multi-layered 3D rendering Neurosurgeons are demanding more from neuroradiologists and increasingly
Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.
Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS Peio RISS ICP-MS Application Specialist aurora Elite Bruker ICP-MS aurora series The aurora series design All-digital
Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system
Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,
Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive
Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier. The Captus 3000 combines a software program with the
Thermo Scientific ART Pipette Tips. superior tips. for any application, any pipette
Thermo Scientific ART Pipette Tips superior tips for any application, any pipette How do we make it easy to select exceptional tips for all the pipette brands you use? It's ART. The Thermo Scientific ART
Counsyl Foresight Carrier Screen. Utmost confidence in every result
Counsyl Foresight Carrier Screen Utmost confidence in every result EXTENDING THE BENEFITS OF CARRIER SCREENING Elevate quality of care with expanded carrier screening (ECS) Carrier screening is used to
Towards High Resolution MS in Regulated Bioanalysis
Towards High Resolution MS in Regulated Bioanalysis Benno Ingelse MSD 3 rd EB focus meeting June 12 th 13 th Brussels, Belgium Contributors Gary Adamson Ken Anderson Kevin Bateman Cynthia Chavez-Eng Inhou
Analysis of formaldehyde in blood of rats during and after inhalation exposure
Analysis of formaldehyde in blood of rats during and after inhalation exposure Sponsor: Research laboratory: P.O. Box 844 3700 AV Zeist The Netherlands Presenter: Dr. A.J. Kleinnijenhuis T +31 88 866 28
Elemental Scientific. Automated Speciation. prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) ICP ICPMS AA
prepfast-ic Automated Speciation prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) Presented at the 015 European Winter Plasma Conference Authors: Aurelien Viscardi, Kyle Uhlmeyer & Patrick Sullivan
High performance ultrasound
High performance ultrasound Philips HD7 XE ultrasound system Redefining high definiti Superb image quality and an array of advanced performance features deliver high definition imaging qualities in a system
Reimagine dentures. Revitalize your lab.
Digital Dentures Reimagine dentures. Revitalize your lab. There has never been a better time to go digital. The demand for dentures is growing, while the overall number of labs continues to decline. This
Analysis of bisphenol A leaching from baby feeding bottles
Agilent Application Solution Analysis of bisphenol A leaching from baby feeding bottles Application Note Consumer Products Author Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India Abstract
numares at a glance company overview 2014 Discover, understand and use biological systems high level NMR analytics
numares at a glance company overview 2014 Discover, understand and use biological systems high level NMR analytics Three benefits of numares 1 Supporting patients to receive better cure based on effective
LCMS Vitamin D3 Method development
LCMS-85 Vitamin D3 Method development Background Vitamin D3 Analysis is in demand in SAP region especially in Singapore and India Clinical Diagnostics and Clinical Research is demanding this application
AadvaTM Lab Scan. from GC Impressive scan accuracy at the speed of light. Digital technology made easy with GC s high-end lab scanner
AadvaTM Lab Scan from GC Impressive scan accuracy at the speed of light Digital technology made easy with GC s high-end lab scanner Digital dentistry is around for a few years now, and many dental technicians
vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15
vii LIST OF TABLES TABLE NO DESCRIPTION PAGE CHAPTER- 1 1.1 System Suitability Parameters and Recommendations 07 1.2 Acidic and Alkaline Hydrolysis 15 1.3 Oxidative Degradation Study 16 1.4 Hydrolysis
PPD S EXPERT HEMATOLOGY AND ONCOLOGY TEAM
HEMATOLOGY ONCOLOGY PPD S EXPERT HEMATOLOGY AND ONCOLOGY TEAM COMMITTED TO ADVANCING DRUG DEVELOPMENT IN ONCOLOGY $ MARKETPLACE COMPLEXITIES increasingly competitive marketplace and rising cost pressures
Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Serum Using UHPLC-TOF
APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Bonnie Marmor PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Serum
Intuitive. Intelligent. Innovative. General Imaging
Intuitive. Intelligent. Innovative. General Imaging INTELLIGENT DESIGN ibeam ARCHITECTURE INTUITIVE WORKFLOW SUPPORT 2 Magic inside Aplio i800 is designed to deliver outstanding clinical precision and
SEE DETAILS THAT MAKE THE DIFFERENCE. bk3000 UROLOGY
SEE DETAILS THAT MAKE THE bk3000 UROLOGY DIFFERENCE EXCEPTIONAL DETAIL UNPARALLELED CONTROL CLARITY COUNTS, and so does speed. You can rely on the bk3000 to deliver high contrast resolution images fast.
Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD
Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD Claude R. Mallet Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S This
CORESTA Recommended Method No. 84
Cooperation Centre for Scientific Research Relative to Tobacco E-Vapour Sub-Group CORESTA Recommended Method No. 84 DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES
amazon speed Innovation with Integrity Ion Trap Performance Beyond Imagination Ion Trap MS
amazon speed Ion Trap Performance Beyond Imagination Innovation with Integrity Ion Trap MS amazon Turning Speed into Solutions The amazon speed ion trap series sets new analytical standards for proteomics
Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System
Introducing the future of DXA Powerful images. Clear answers. Horizon DXA System Hologic turns ideas into innovation. Again. Hologic cares about you and your patients about keeping their bones healthy,