Success of Spinal and Epidural Labor Analgesia

Size: px
Start display at page:

Download "Success of Spinal and Epidural Labor Analgesia"

Transcription

1 Anesthesiology 2009; 111: Copyright 2009, the American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Success of Spinal and Epidural Labor Analgesia Comparison of Loss of Resistance Technique Using Air versus Saline in Combined Spinal-Epidural Labor Analgesia Technique Lydia S. Grondin, M.D.,* Kenneth Nelson, M.D., Vernon Ross, M.D., Orlando Aponte, M.D., Sherman Lee, M.D., Peter H. Pan, M.D. Background: Comparison of air versus saline for loss of resistance technique (LORT) in combined spinal epidural labor analgesia (CSE) has not been evaluated, and neither has the relation between CSE characteristics (the presence/absence of initial spontaneous clear fluid return or upon aspiration) and spinal/epidural analgesia outcomes. The authors hypothesized that there is no difference in the spinal analgesia success or epidural catheter efficacy between using air versus saline LORT for CSE. Methods: A total of 360 patients were randomized to air or saline LORT for CSE. Primary outcome was spinal analgesia success as defined by verbal pain score of no more than 3 at 15 min after spinal dose administration. Secondary outcomes were CSE characteristics, catheter replacement, and average hourly epidural drug consumption. Results: Results from 345 patients were analyzed. Spinal analgesia success, epidural catheter replacement, and drug consumption were not different between using air or saline LORT and were also independent of the presence/absence of fluid return on aspiration if initial spontaneous fluid returned to the spinal needle. However, epidural catheters inserted in absence of initial fluid return had a significantly higher catheter replacement rate (28.6%) than the 4.1% among those with initial fluid return (P < 0.03). Conclusions: Spinal analgesia success rate and epidural efficacy are independent of whether air or saline is used for LORT during CSE. Practice of aspiration for fluid after observing initial fluid return may be unnecessary because this practice does not alter spinal/epidural analgesia outcomes. However, epidural catheters inserted with the absence of initial fluid returned to spinal needle may pose a high failure risk. EVEN though combined spinal epidural labor analgesia (CSE) technique has become widely used since its introduction in 1982, the use of air versus saline in the loss of resistance technique (LORT) for identifying the epidural space during CSE remains a source of ongoing debate. 1 6 * Assistant Professor, Department of Anesthesiology, University of Vermont/ Fletcher Allen Health Care, Burlington, Vermont; Associate Professor, Previous Fellows, Professor, Department of Anesthesiology, Wake Forest University School of Medicine, Winston-Salem, North Carolina. Received from the Department of Anesthesiology, Wake Forest University School of Medicine, Winston-Salem, North Carolina. Submitted for publication October 8, Accepted for publication February 11, Support was provided solely from institutional and/or departmental sources. Presented in part as a poster discussion presentation at the American Society of Anesthesiology Annual Scientific meeting, at San Francisco, California, October 14, 2007, and as an oral presentation at the Society of Obstetric Anesthesia and Perinatology Annual Scientific meeting, Hollywood, Florida, April 27, Timothy J. Brennan, Ph.D., M.D. served as Acting Editor-in-Chief for this manuscript. Address correspondence to Dr. Grondin: 111 Colchester Avenue, Fletcher Allen Health Care, Dept of Anesthesiology, WP2, Burlington, Vermont ccpgood@ yahoo.com. Information on purchasing reprints may be found at www. anesthesiology.org or on the masthead page at the beginning of this issue. ANESTHESIOLOGY s articles are made freely accessible to all readers, for personal use only, 6 months from the cover date of the issue. Advocates of the air LORT report a longer time to onset and reduced quality of analgesia with use of saline LORT in traditional epidural analgesia. 2 More importantly, a number of well-respected authors as proponents of using air LORT for CSE claim that the use of saline may cause confusion with cerebrospinal fluid (CSF) or dural tenting during the needle-through-needle CSE technique and may result in spinal analgesia failure. 3 6 Despite the widespread use of CSE technique, the failure rate of spinal analgesia or anesthesia has been reported ranging from 0.5% to 17%. 7,8 It has been suggested that the spinal failures were the result of dural tenting (instead of puncture) and/or false CSF return when saline LORT was used, lateral placement of epidural needle, misidentification of epidural and/or intrathecal space, medication errors, or anatomical abnormalities. However, whether the use of saline LORT (vs. air) with CSE increases spinal analgesia failure is unknown and has not been studied. There are well-respected advocates on both sides, but there is no scientific evidence to support either view, resulting in a strongly polarized controversy among practicing anesthesiologists on the use of air versus saline LORT with CSE. Previous studies on air or saline LORT are limited to studying traditional epidural techniques but not CSE or spinal analgesia. Furthermore, the relation between the characteristics of CSE (namely the presence or absence of spontaneous fluid return to the spinal needle hub, and the yield of fluid from aspiration before and/or after spinal drug administration) and the outcomes of spinal and/or epidural analgesia have not been studied in a prospective controlled manner. We hypothesized that there would be no difference in the spinal analgesia success rate or epidural catheter efficacy between using saline versus air in LORT during CSE technique. Materials and Methods After securing Institutional Review Boards (Forsyth Medical Center Institute Review Board, Winston-Salem, NC, and Wake Forest University Institute Review Board, Winston-Salem, NC) approval and written informed consent, 360 women in active labor and requesting neuraxial labor analgesia were randomized to have CSE placement using either air or saline in LORT. Inclusion criteria were: cervical dilation of no more than 8 cm, verbal rating score for pain of at least 6 of 10 maximum, 165

2 166 GRONDIN ET AL. vertex singleton pregnancy, and no medical/obstetric contraindications for CSE placement. Exclusion criteria were: American Society of Anesthesiologists physical status greater than II or weight greater than 114 kg. Computer-generated randomization was used for randomized group assignment. The randomized group assignment was placed sequentially on pages inside a notebook, from which the anesthesiologist performing the procedure obtained the randomized group assignment for the current subject sequentially and without the knowledge of the previous or future subject group assignment. Except for the anesthesiologist performing the CSE procedure, the patient, the nurses, the data collector, and interpreters were blinded to the group assignment. Upper level anesthesia residents with over 2 months of successful obstetric anesthesia training experiences, obstetric anesthesia fellows, and attending obstetric anesthesiologists, all of whom are comfortable with the CSE procedure using either air or saline LORT, participated in placing the blocks. All trainees were supervised by an attending obstetric anesthesiologist. The patient was placed in the sitting position. After the back was sterilely prepared and draped, 1% lidocaine was injected subcutaneously for local anesthesia in the lower lumbar vertebral interspace between L2 and L5 and chosen by the anesthesiologist performing the procedure after examining patient s back. The epidural space was located using 3 ml of air (group Air) or 3 ml of saline (group Saline) for the LORT with a glass syringe and a 17-gauge, 89-mm Weiss epidural needle (Becton Dickinson and Company, Franklin Lakes, NJ). With identification of the epidural space, the full 3-ml volume in the syringe was injected into the epidural space according to their randomized group assignment. If part of the volume in the syringe was lost during or before successful identification of epidural space, the syringe was refilled back to 3 ml with air or saline for injection according to the group assignment before successful identification of the epidural space. The 3-ml volume used and injected per our study design was to ensure consistency and control in volume injected epidurally between patients and groups. Using the needle through needle technique, a noninterlocking 27-gauge, 119-mm Whitacre spinal needle (Becton Dickinson and Company) was advanced through the Weiss needle until the hubs touched to reach the subarachnoid space. The distal tip of the spinal needle extended 13 mm past the distal tip of the Weiss epidural needle. Spontaneous fluid return to the needle hub as well as presence or absence of fluid return from preinjection and postinjection aspiration for CSF using the 3-ml syringe used for administering the spinal dose was recorded. The presence of spontaneous fluid returning to the spinal needle hub was considered as identification of the intrathecal space. Once identified, the spinal dose administered consisted of 0.6 ml of bupivacaine 2.5 mg/ml with 0.4 ml of fentanyl 50 g/ml. After removal of the spinal needle, a 19-gauge, triport epidural catheter (Becton Dickinson and Company) was then inserted and secured with 5 6 cm left inside the epidural space. The patient was placed in a position with a folded up blanket (roll) placed behind the hip and lumbar areas to keep tilted laterally to the left or right position as she felt comfortable in and as tolerated by both the patient and fetus. No epidural medications were administered until 15 min after the spinal dose administration. Fetal heart rate, maternal hemodynamics, verbal pain score (0 indicating no pain and 10 indicating the worst pain imaginable) and verbal pruritus score (0 indicating no pruritus and 10 indicating worst pruritus imaginable) were recorded before the CSE procedure and then every 5 min for 20 min after spinal needle removal by the anesthesiologist performing the CSE procedure. Another anesthesiologist or research nurse blinded to the group assignment collected the data for the rest of the study after the initial 20 min of the CSE procedure. Hypotension (defined as systolic blood pressure decrease greater than 20% from preprocedure blood pressure) was treated with increments of 5 to 10 mg of ephedrine per usual practice. Evaluation of the spinal dose efficacy consisted of verbal pain score and sensory level to cold temperature. If blood returned spontaneously or with aspiration through the epidural catheter at any time, the catheter was injected with 0.5 ml of saline incrementally and pulled back 0.5 cm incrementally if needed until the catheter was cleared of blood or with 3 cm of catheter remained in epidural space. If unsuccessful, the catheter was removed, and a new epidural catheter was inserted using the same LORT (3 ml of air or saline) as previously assigned. The absence or presence of paresthesia at the time of insertion of the spinal needle or epidural catheter was documented. Paresthesia was defined as a tingling or mild electrical shock sensation or the sensation of hitting a funny bone but of less or same intensity. If paresthesia did not resolve and lasted more than 1 min, procedure was abandoned and patient was excluded from the study. After the initial 15 min, an intrathecal test dose of 2 ml of lidocaine 20 mg/ml was administered via the epidural catheter; if negative, epidural patient-controlled analgesia was initiated in the usual manner by using bupivacaine 1.25 mg/ml and fentanyl 2 g/ml with a basal infusion rate of 12 ml/h, a demand dose of 6 ml, and a 10-min lockout. Patients were assessed for pain level every 2 h after initiation of patient-controlled epidural analgesia or more frequently if patient reported a pain score of greater than 3 or required physician-administered boluses until verbal pain score reduced to no more than 3. For inadequate labor analgesia (defined as verbal pain score greater than 3), catheter adjustment by pulling catheter back to 3 cm inside the epidural space if

3 AIR VS SALINE LOSS RESISTANCE CSE LABOR ANALGESIA 167 unilateral block noted or additional physician administered boluses of bupivacaine 2.5 mg/ml first, and then lidocaine 20 mg/ml if needed, both given in increments of 5 ml up to a total of 10 ml each, were allowed to achieve adequate analgesia as needed. If analgesia was still inadequate (verbal pain score greater than 3) after physician-administered boluses and catheter manipulation, epidural catheters were replaced, and the time and reason of replacement were documented. The total number of bolus doses was determined, as was the presence or absence of sensory levels and verbal pain score during the physician-administered boluses up to a maximum of 20 ml. In the case in which there was no spontaneous clear fluid return into the spinal needle hub after insertion of the spinal needle and removal of spinal needle stylet, spinal dose was not administered, and a triport epidural catheter was inserted 5 6 cm inside the epidural space after spinal needle removal as in usual manner. The lack of spontaneous clear fluid return was defined as failed spinal analgesia by our study design. Then, an intrathecal test dose of 2 ml of lidocaine 20 mg/ml was administered followed 5 min later by an intravenous test dose of 5 ml of lidocaine 20 mg/ml if the intrathecal test was negative. The rest of the epidural patient-controlled analgesia and breakthrough pain management was the same as described above. The primary outcome measure was the success of spinal labor analgesia as defined by verbal pain score of no more than 3 at 15 min after spinal dose administration. Secondary outcomes were spontaneous fluid return, fluid return upon preinjection and postinjection aspiration, epidural catheter replacement rate, and the average hourly total amount of epidural medications required within 4 h from initial epidural catheter insertion. The average hourly total amount (ml/h) of epidural drug used (reported as ml/h in equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml) was calculated as the sum total of the epidural patientcontrolled analgesia basal infusion amount, demand doses, and physician-administered boluses divided by the actual duration of consumption up to 4 h. For the purpose of this calculation, we estimated the local anesthetic-sparing effect of fentanyl as follows: (1) bupivacaine 1.25 mg/ml estimated as 0.85 equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml; (2) bupivacaine 2.5 mg/ml estimated as 1.70 equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml; (3) lidocaine 20 mg/ml estimated as similar to bupivacaine 5 mg/ml and 3.40 equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml. Epidural catheter efficacy was measured by requirement (or its lack of) for epidural catheter replacement, physician-administered supplement boluses, and the average hourly total amount of epidural drug used within 4 h of analgesia initiation. Statistical Methods On the basis of our quality assurance data on CSE success rate and previous published reports on success rate of CSE spinal labor analgesia ranging from 83 to 99%, we considered a difference between 98% versus 90% in success rate between groups to be clinically significant and relevant. 7,8 A priori power analysis revealed that a sample size of 160 per group was needed to demonstrate the stated difference (90% vs. 98%) between groups in the primary outcome variable to achieve a power of 0.8 and an alpha of An estimated total of 360 subjects was planned for enrollment, with the goal to obtain at least 320 evaluable subjects. A separate subgroup analysis was also planned a priori to compare spinal analgesia success and/or epidural catheter replacement rate between patients with different CSE characteristics (those with initial clear fluid returned to spinal needle vs. those without and those with initial clear fluid return and with positive aspiration before and/or after spinal drug administration vs. those with negative aspiration). For statistical analysis, SigmaStat version 3.01 for Windows version (SPSS Inc., Chicago, IL) was used. Incidence and proportion data were compared between groups using chi-square test or Fisher exact test. The average hourly total epidural drug consumption was compared between groups using 2-tailed unpaired t test. For continuous data that did not meet parametric assumptions, the Mann-Whitney U test was used. Change in continuous measures over time within each group was determined using one-way analysis of variance for repeated measures and two-way analysis of variance for comparison between groups with planned post hoc Tukey test as needed. P 0.05 is considered statistically significant. Data are presented as mean values SD, median values, interquartile range, and percentages as appropriate. Results Patient Enrollment Of the 360 laboring patients enrolled, 15 were excluded, resulting in the remaining 173 patients in the Air group and 172 in the Saline group being included for statistical analysis. Among those 15 excluded patients, 3 had unintentional dural puncture (2 in Air group, 1 in Saline group), 1 had intrathecal catheter (in Air group), 3 delivered rapidly within min after administration of spinal drug (all in Air group), 1 did not receive spinal drug injection (Saline group) because of significant paresthesia during spinal needle insertion, 1 had a protocol violation (due to premature administration of epidural test doses), and 2 had incomplete data set (both in Saline group), and 4 were consented but not studied. None of the patients with unintentional dural puncture had resulting clinical pneumocephalus. Demographics and Primary Outcome Measures Patient demographics, obstetric data, and anesthesia provider experience were comparable in the two treat-

4 168 GRONDIN ET AL. Table 1. Demographics and Obstetrical and Anesthetic Variables Group Air (n 173) Group Saline (n 172) Age, years Weight, kg Height, cm Average gestational age, weeks Gravidity Median, mode 2, 2 2, 1 Interquartile range Range Parity Median, mode 1, 0 1, 0 Interquartile range Range Average cervical dilation before CSE, cm Delivered within 2 h from CSE, % 15% 14% Cesarean delivery, % 11.6% 12.2% Fetal weight, g 3, , Apgar score (at 1 and 5 min) Median 1 min min 9 9 Mode 1 min min 9 9 Interquartile range 1 min min Range 1 min min Anesthesia provider years of training experience (Fellows 5 yrs, Attendings* 10 yrs, residents n th yrs in residency) Median, mode 5, 5 5, 5 Interquartile range Range Anesthesia performed by provider in fourth or higher years of training 93% 90% (senior resident, fellows or attendings), % Lumbar vertebral interspace used for CSE (1 L12, 2 L23, 3 L34, 4 L45, 5 L5S1 interspace ) Median, mode 3, 3 3, 3 Interquartile range Range Data are expressed as mean SD, percent, median or mode unless otherwise specified. There are no statistical differences in all variables in the Table when compared between groups. * All attending anesthesiologists participating in this study had at least 10 years of obstetric anesthesia experience; L12 interspace between lumbar level 1 and 2; L23 between lumbar level 2 and 3, etc. CSE Combined spinal epidural technique. ment groups (table 1). The overall rate of successful labor spinal analgesia for all subjects was 93.9%, and there was no significant difference between Air (94.2%) and Saline (93.6%) groups. There were seven patients who had no initial spontaneous clear fluid return (4 in Saline group and 3 in Air group) through the spinal needle, and the epidural catheter was inserted without having spinal drug administered as per our study protocol. None of these three patients in the Air group required epidural catheter replacement, whereas two of the four patients in the Saline group required epidural catheters replacement subsequently even though they provided adequate analgesia at the initiation of the epidural analgesia. When excluding those seven patients without initial spontaneous clear fluid return from spinal analgesia failure, the overall rate of successful labor spinal analgesia after first observing clear fluid return to spinal needle hub was 95.9% for all subjects, without significant differences between groups (95.9% in Air group vs. 95.8% in Saline group; table 2). Secondary Outcome Measures and Analysis The incidence of epidural catheters requiring replacement within the first 4 h after initial epidural catheter insertion was similar between Air and Saline groups (2.9% or 5 of 173 in Air group vs. 5.2% or 9 of 172 in Saline group, 4.1% or 14 of 345 for all patients combined). Also similar was the amount of the average

5 AIR VS SALINE LOSS RESISTANCE CSE LABOR ANALGESIA 169 Table 2. Primary and Secondary Outcomes Air Group (n 173) Saline Group (n 172) Rate of initial spontaneous fluid return to spinal needle hub* 98.3% (173/176*) ( %) 97.7% (169/173*) ( %) Spinal analgesia failure rate Including those without initial free fluid return 5.8% (10/173) ( %) 6.4% (11/172) ( %) Not including those without initial free fluid return 4.1% (7/170) ( %) 4.2% (7/168) ( %) Among those with positive initial fluid return but negative 0% (0/20) ( %) 12.5% (2/16) ( %) preinjection aspiration Among those with positive initial fluid return but negative 0% (0/23) ( %) 5.3% (1/19) ( %) postinjection aspiration Rate of positive preinjection aspiration 88.2% (150/170 ) ( %) 90.5% (152/168 ) ( %) Rate of positive postinjection aspiration 86.5% (147/170 ) ( %) 88.7% (149/168 ) ( %) Epidural catheter replaced within 4 h after initiation of 2.9% (5/173 ) ( %) 5.2% (9/172 ) ( %) patient-controlled epidural analgesia Patients required physician-administered boluses 19.7% (34/173 ) ( %) 17.5% (30/172 ) ( %) Average hourly total epidural medication (equivalents of ml/h bupivacaine 1.25 mg/ml with fentanyl 2 g/ml) Verbal pain score, average SD Before CSE min after spinal drug administration Highest sensory block to cold at 15 min after spinal drug.. injection (C7 0, T1 1, T2 2,...,T12 12, L1 13,..., L5 17) Median, mode 5, 4 5, 4 Interquartile range Range Pruritus score (0 10), average SD Inadvertent dural puncture# By epidural needle 1.1% (2/176#) ( %) 0.6% (1/173#) ( %) By epidural catheter (spinal catheter) 0.6% (1/176#) ( %) 0% (0/173#) ( %) Data are expressed as mean SD, percent, median or mode unless otherwise specified. There are no statistical differences in all variables in the table when compared between groups. * Denominator in Air group is 176 (including three patients delivered quickly without full spinal analgesia) and 173 for Saline group (including one patient without spinal drug administration due to paresthesia); 95% confidence interval by modified Wald method; Denominators include those patients with initial clear fluid return to spinal needle hub: 170 for Air group and 168 for Saline group; Denominators include patients with or without initial clear fluid return to spinal needle hub: 173 for Air group and 172 for Saline group. Average hourly total epidural medication required includes epidural basal infusion, epidural patient-controlled demand boluses, and physician-administered boluses combined and then expressed as an average per hour (physician-administered boluses are converted to equivalents as follows given the local anesthetic sparing effect of fentanyl: bupivacaine 1.25 mg/ml 0.85 times equivalent of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml, bupivacaine 2.5 mg/ml 1.7 times equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml, and lidocaine 20 mg/ml 3.40 times equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml); # denominators include patients with inadvertent dural puncture or intrathecal catheters: 173 (2 dural puncture 1 spinal catheter) 176 for Air group, and 172 (1 dural puncture) 173 for Saline group. CSE Combined spinal-epidural labor analgesia. hourly total epidural medication required for labor analgesia (18 6 ml/h vs ml/h in equivalents of bupivacaine 1.25 mg/ml with fentanyl 2 g/ml for Air and Saline groups, respectively) and percent of patients requiring physician-administered boluses (19.7% or 34 of 173 in Air vs. 17.4% or 30 of 172 in Saline group). When including only those patients with initial spontaneous clear fluid return to spinal needle hub, the occurrence of negative continuous fluid aspiration before spinal drug injection (11.8% or 20 of 170 in Air group vs. 9.5% or 16 of 168 in Saline group; overall 10.7% or 36 of 338) or after spinal drug injection (13.5% or 23 of 170 in Air group vs. 11.3% or 19 of 168 in Saline group; overall 12.5% or 42 of 338) were similar between groups. Among those with positive initial spontaneous fluid return to the spinal needle but negative continuous fluid return on preinjection aspiration (20 in Air group, 16 in Saline group, 36 overall), the overall spinal analgesia success rate (94.4% or 34 of 36) after spinal drug administration among these 36 patients was similar to the overall success rate (95.9%) of all 338 patients (including all patients both with positive and negative fluid return upon aspiration after the initial spontaneous clear fluid returned to the spinal needle hub). Twenty patients in the Air group had negative continuous fluid return on aspiration after initial spontaneous fluid return, but none had failed spinal analgesia or required epidural catheter replacement after spinal drug administration, whereas 2 of 16 patients in the Saline group with same setting had failed spinal analgesia and required subsequent epidural catheter replacement within 4 h after spinal drug administration. However, these differences between groups were not statistically significant. Similarly, among those with positive initial fluid return to the spinal needle but negative continuous fluid return on postinjection aspiration (23 in Air group, 19 in Saline group, 42 overall), the overall spinal analgesia success rate was 97.6% and was not different from that of all 338

6 170 GRONDIN ET AL. patients. Among those without initial clear fluid return to spinal needle hub, the epidural catheter replacement rate within first 4hwas28.6% (95% CI %) and was significantly (P 0.03) higher than the 3.6% (95% CI %) rate among those 338 patients with presence of initial clear fluid return to the spinal needle hub. During the initial epidural catheter placement, blood returned either spontaneously or with aspiration in 11 (3.2%) of the epidural catheters (6 in Air group, 5 in Saline group), among which 9 of them (5 in Air group and 4 in Saline group) were cleared of blood with maneuvers described in the Methods section and provided adequate analgesia without the need for subsequent replacement within the study period. The remaining two catheters were replaced, and new catheters were reinserted using the same LORT technique (3 ml of air or saline) as previously assigned, and both provided adequate analgesia for the duration of the study period. Among those few patients without initial spontaneous fluid return, there was no inadvertent intravenous catheter. There was no excessively high block or total spinal among our subjects. All paresthesia occurred with the spinal needle or epidural catheter insertion was transient except in one excluded subject. The incidences of paresthesia with the spinal needle insertion were 6.2% for Air group and 6.3% for Saline group and 24% for both groups with epidural catheter insertion, all without differences between groups. Discussion The results of this study demonstrate three clinically relevant findings that have not been previously studied in a prospective controlled manner but related to clinical situations and decisions encountered almost daily by obstetric anesthesiologists. The first is that the success of spinal analgesia, the success of obtaining initial spontaneous fluid return through the spinal needle, and subsequent epidural catheter efficacy with needle through needle CSE technique is the same regardless of using saline or air for LORT in identifying the epidural space. Second, the likelihood of successful spinal analgesia in the setting when clear fluid cannot be aspirated before or after spinal drug injection after positive initial spontaneous fluid return to the spinal needle hub was the same as those with fluid return upon preinjection and/or postinjection aspiration. Third, the risk of epidural catheter failure is significantly higher if no initial clear fluid returned to the spinal needle during the CSE technique. Spinal Analgesia Failure and Epidural Efficacy Air versus Saline Lack of spontaneous CSF flow at the spinal needle hub on initial placement accounted for 1.7% in the Air group and 2.2% in the Saline group, which are similar to the previously reported failure rates of 0.5 5% The much lower incidence of failed CSF flow before spinal drug administration reported by Albright et al. could be explained in part by the retrospective nature of their report and their practice of redirecting the spinal needle if CSF was not obtained upon first pass, which we did not do by our study design. 12 Of note, Albright et al. injected sufentanil up to 20 g with or without bupivacaine through the spinal needle in 11 patients in whom they were unable to obtain continuous CSF flow. Of the eleven patients, eight reported some pain relief. However, the report did not specify if any initial spontaneous CSF fluid return was observed. Furthermore, even an inadvertent epidural administration of 20 g of sufentanil together with its associated systemic absorption may provide significant initial pain relief. 13 In our study, we considered the absence of initial fluid return as spinal analgesia failure and did not administer any intrathecal drug. The spinal analgesia was also considered to have failed if the patient did not obtain adequate pain relief from the spinal dose. This occurred in 4.1% and 4.2% of patients in the Air and Saline groups, respectively. The rate of spinal anesthesia failure for surgical patients noted to have free CSF flow has been reported between 2.0% to as high as 15%. 7,8 Our failure rate is in the low range of this, possibly resulting from the sympathetic nature of labor pain, which does not require the same level of block density as surgery. It is interesting to note that among all 14 patients who had failed spinal analgesia with positive initial spontaneous fluid return to the spinal needle hub, continuous fluid return was observed in 12 of the 14 patients at both preinjection and postinjection aspiration. One can only speculate that these failures (especially for the Air group in which no fluid was injected before the spinal needle insertion) may possibly be due to maldistribution, anatomical abnormalities, individual differences in pain and analgesic sensitivity, and varying intensity of labor pain and progression. Given the very similar success rate of spinal analgesia and epidural efficacy between Air and Saline groups, it is evident that 3 ml of saline injected epidurally did not seem to cause misidentification of spinal fluid return from intrathecal space when spinal needle was inserted during a CSE procedure. Other studies have suggested both risks and benefits in using saline versus air in LORT for traditional epidural placement. 2 Weused3mlofair or saline to standardize the volume injected epidurally in the study for control comparison between groups. In our clinical practice, when air is used, practitioners often inject less than 0.25 to 0.5 ml when change or loss of resistance is identified. This study does not rule out the possibility of misidentification of fluid as CSF if a larger amount of saline was injected epidurally during LORT. Three milliliters of saline may have been too small a volume to cause maldistribution of local anesthetic in the epidural space or tenting of the dura, which has been shown to occur during the CSE technique in cadaver epiduroscopy studies and has been theorized to

7 AIR VS SALINE LOSS RESISTANCE CSE LABOR ANALGESIA 171 prevent the spinal needle from reaching the intrathecal space. 14,15 The acceptable length for spinal needle extension from the tip of the epidural needle has been established as mm. Longer needles can lead to increased paresthesias with insertion, and shorter needles would cause failure to obtain spinal fluid. 15 Our spinal needles extend 13 mm from the tip of the Weiss needle, leading us to believe that this combination should lead to adequate results. Negative Preinjection Aspiration Even when there was no continuous fluid return upon aspiration after observing initial spontaneous fluid return to the spinal needle hub, an overall 94.4% success rate of spinal analgesia performed with a needle through needle CSE was observed. In a search of the literature, this outcome in CSE technique is a clinically significant question that has not been previously studied in a prospective controlled manner. Occurrence of positive initial spontaneous fluid return with subsequent absence of fluid upon aspiration is not uncommon in daily practice, and the chance of success of the subsequent intrathecal dose has previously been unknown. As long as initial clear spontaneous fluid was observed at the spinal needle hub, our data demonstrated a similarly high success rate of spinal analgesia. Therefore, our data suggest the practice of aspiration before injection may be unnecessary because it may not yield any additional useful clinical information to the outcome of the spinal analgesia. We do not know if the success rate would be the same in the similar scenario for spinal anesthesia instead of analgesia under CSE or spinal anesthesia alone. Negative Postinjection Aspiration Another interesting piece of information this study yielded is that there is a relatively high rate of negative postinjection aspiration of 12.4% (42 of 338 all combined, 23 in Air group, 19 in Saline group), even in the presence of initial spontaneous fluid return to spinal needle at spinal needle insertion. All of these 23 patients in Air group and 18 of those 19 patients in Saline group had successful spinal analgesia despite negative postinjection aspiration. Munhall et al. showed that 2 (1%) of 198 spinal anesthetics had negative postinjection aspiration, and both patients had adequate surgical spinal anesthesia. 16 The lower incidence of negative postinjection aspiration in their study may have been due to larger needle size (18- to 25-guage) and the use of a spinal technique versus the CSE technique. In a prospective study of 1,891 patients, Tarkkila et al. found the failure rate of spinal anesthesia with CSF flow present postinjection in a surgical setting was 2.9%. The failure rate increased to 3.8% if postinjection aspiration was negative. However, these differences were insignificant, and their overall failure rate was 3.1%. 17 These findings were similar to ours showing that confirmation of CSF flow during or after injection may also be an unnecessary practice. However, in our study, this group of patients was small, and the significance of these findings would have to be confirmed in an investigation with a larger sample size. Epidural Catheter Function The epidural catheter replacement rate was significantly (P 0.03) higher among those patients when epidural catheter was inserted after not being able to first obtain spontaneous CSF to the spinal needle hub in the CSE technique. Of these patients, 28.6% required their epidural catheters replaced within 4 h from initial epidural catheter placement, whereas all patients included in the Air and Saline groups had only an overall 2.9% and 5.2% of patients requiring replacement. Among all the patients with the presence of initial fluid returned in the spinal needle, the overall epidural catheter replacement rate was only 3.6%. This result confirms and is comparable to our previous study, suggesting a 22% epidural catheter replacement rate during labor among similar patients in similar settings when no spontaneous initial CSF flow appeared at the spinal needle hub during needle through needle CSE technique. 18 When data from this previous study are combined with the current study, the incidence of epidural catheter replacement rate among those without initial clear fluid return to the spinal needle during a labor CSE procedure is 24% (6 of 25, 95% CI %) and is still significantly higher than the 3.6% (95% CI %) among all patients with initial fluid return (P ). The absence of initial spontaneous fluid return after insertion of spinal needle in a CSE procedure may potentially indicate a high risk of failure in the epidural catheter inserted without repeating the epidural procedure. Collectively, this strongly suggests reidentification of the epidural space at a different angle or interspace in such settings is warranted. Despite statistically significant differences observed, both the number of patients in this setting from the current study and our previous study are small, further studies are needed to confirm this finding. Issues or Concerns about Using Air versus Saline in LORT The use of saline versus air for LORT with traditional epidural technique has been debated for years and been addressed often with nonconclusive reports of air-associated patchy blocks, wet taps and even subcutaneous emphysema. 2,19 21 Our study on CSE showed no significant difference in the incidence of spinal analgesia success, epidural efficacy, and dural puncture between Air and Saline groups. However, we chose only providers accustomed to using both air and saline for the LORT. Previous studies had evaluated air versus saline LORT only in traditional epidural techniques but not in CSE or spinal analgesia. Valentine et al. were the first to report a controlled study using 4 ml of air or saline for LORT

8 172 GRONDIN ET AL. with traditional epidural technique and epidural analgesia. The air group had a higher incidence of unblocked dermatomal segments that were completely relieved with an additional dose of medication in both groups without the need of catheter replacement. 22 Similar findings were elicited in another study by Beilin et al. in evaluating the success in initiation of traditional epidural analgesia. 23 Our study shows that whether 3 ml of air or saline is used for the LORT with CSE did not affect inadvertent dural puncture rate, number of catheter replacements, or how much epidural medication the patients required over the 4-h study period. The decision of using air or saline LORT for CSE labor analgesia should therefore not be based on spinal analgesia success or epidural catheter efficacy; rather, it should be based on other reasons and outcomes with scientific evidences as well as the practitioner s experience level with air or saline LORT. Conclusion Our study shows that there is no difference in the failure rate of spinal analgesia or efficacy of the epidural catheter function when using either air or saline in loss of resistance technique for CSE labor analgesia. This study also suggests that successful spinal analgesia was obtained as frequently in the setting of initial spontaneous fluid flow return without the ability to aspirate as in those patients where aspiration was possible. This cannot be extrapolated to spinal anesthesia for surgery and should be further studied in a larger population. We also determined that the risk of epidural catheter failure is significantly higher if spontaneous CSF flow is not obtained upon passing the spinal needle in a CSE technique. However, this was a small subset of patients, and larger studies with this finding as a primary outcome would be needed to confirm this finding. References 1. Simmons SW, Cyna AM, Dennis AT, Hughes D: Combined spinal-epidural versus epidural analgesia in labor. Cochrane Database of Systematic Reviews 2007; Issue 3, Art. No. CD003401, DO1: / CD00341.pub2 2. Shenouda PE, Cunningham BJ: Assessing the superiority of saline versus air for use in the epidural loss of resistance technique: A literature review. Reg Anesth Pain Med 2003; 28: Russell R, Douglas J: Controversies: Loss of resistance to saline is better than air for obstetric epidurals. Int J Obstet Anesth 2001; 10: D Angelo R: New techniques for labor analgesia: PCEA and CSE. Clin Obstet Gynecol 2003; 46: Robinson PN, Barker J, Mcleod GA: Maternal satisfaction and combined spinal epidural analgesia. Int J Obstet Anesth 1995; 4: Cook TM: Combined spinal epidural anaesthesia: A new technique. Int J Obstet Anesth 1999; 8: Hoppe J, Popham P: Complete failure of spinal anaesthesia in obstetrics. Int J Obstet Anesth 2007; 16: Levy JH, Islas JA, Ghia JN, Turnbull C: A retrospective study of the incidence and causes of failed spinal anesthetics in a university hospital. Anesth Analg 1985; 64: Agresti A, Coull BA: Approximate is better than exact for interval estimation of binomial proportions. Am Stat 1998; 52; Norris MC, Grieco WM, Borkowski M, Leighton BL, Arkoosh VA, Huffnagle HJ, Huffnagle S: Complications of labor analgesia: Epidural versus combined spinal epidural techniques. Anesth Analg 1994; 79: Pan PH, Bogard TD, Owen MD: Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: A retrospective analysis of 19,259 deliveries. Int J Obstet Anesth 2004; 13: Albright GA, Forster RM: The safety and efficacy of combined spinal and epidural analgesia/anesthesia (6,002 blocks) in a community hospital. Reg Anesth Pain Med 1999; 24: Coda BA, Brown MC, Schaffer R, Donaldson G, Jacobson R, Hautman B, Shen DD: Pharmacology of epidural fentanyl, alfentanil, and sufentanil in volunteers. ANESTHESIOLOGY 1994; 81: Holmstrom B, Rawal N, Axelsson K, Nydahl P: Risk of catheter migration during combined spinal epidural block: Percutaneous epiduroscopy study. Anesth Analg 1995; 80: Herbstman CH, Jaffee JB, Tuman KJ, Newman LM: An in vivo evaluation of four spinal needles used for the combined spinal epidural technique. Anesth Analg 1998; 86: Munhall RJ, Sukhani R, Winnie AP: Incidence and etiology of failed spinal anesthetics in a university hospital: A prospective study. Anesth Analg 1988; 67: Tarkkila JP: Incidence and causes of failed spinal anesthetics in a university hospital: A prospective study. Reg Anesth 1991; 16: Thomas JA, Pan PH, Harris LC, Owen MD, D Angelo R: Dural puncture with a 27-gauge Whitacre needle as part of a combined spinal-epidural technique does not improve labor epidural catheter function. ANESTHESIOLOGY 2005; 103: Saberski LR, Kondamuri S, Osinubi OYO: Identification of the epidural space: Is loss of resistance to air a safe technique? A review of the complications related to the use of air. Reg Anesth 1997; 22: Aida S, Taga K, Yamakura T, Endoh H, Shimoji K: Headache after attempted epidural block. The role of intrathecal air. ANESTHESIOLOGY 1998; 88: Stride PC, Cooper GM: Dural taps revisited. A 20-year survey from Birmingham Maternity Hospital. Anaesthesia 1993; 48: Valentine SJ, Jarvis AP, Shutt LE: Comparative study of the effects of air or saline to identify the extradural space. Br J Anaesth 1991; 66: Beilin Y, Arnold I, Telfeyan C, Bernstein HH, Hossain S: Quality of analgesia when air versus saline is used for identification of the epidural space in the parturient. Reg Anesth Pain Med 2000; 25:596 9

Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions?

Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions? Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions? Dr Mark Esler Queen Charlotte s and Chelsea Hospital Imperial College Healthcare NHS Trust 2 nd October 2013 2 kangaroos and

More information

Introduction of a New Concept of Pain Management during Labor and a Novel Technique for Pain Free Labor

Introduction of a New Concept of Pain Management during Labor and a Novel Technique for Pain Free Labor Open Journal of Anesthesiology, 2012, 2, 79-83 http://dx.doi.org/10.4236/ojanes.2012.23019 Published Online July 2012 (http://www.scirp.org/journal/ojanes) 1 Introduction of a New Concept of Pain Management

More information

DURAL PUNCTURE EPIDURAL ANALGESIA IS NOT SUPERIOR TO CONTINUOUS LABOR EPIDURAL ANALGESIA

DURAL PUNCTURE EPIDURAL ANALGESIA IS NOT SUPERIOR TO CONTINUOUS LABOR EPIDURAL ANALGESIA DURAL PUNCTURE EPIDURAL ANALGESIA IS NOT SUPERIOR TO CONTINUOUS LABOR EPIDURAL ANALGESIA Deepak Gupta *, Arvind Srirajakalidindi *, Vitaly Soskin ** Abstract Background: Some anesthesiologists consider

More information

Combined spinalepidural. epidural analgesia in labour (review) By Neda Taghizadeh

Combined spinalepidural. epidural analgesia in labour (review) By Neda Taghizadeh Combined spinalepidural versus epidural analgesia in labour (review) By Neda Taghizadeh Cochrane review Cochrane collaboration was founded in 1993 and is named after Archie Cochrane (1909-1988), British

More information

Success going from failure to failure without loss of enthusiasm

Success going from failure to failure without loss of enthusiasm Success going from failure to failure without loss of enthusiasm Failure of neuraxial analgesia: factors within & beyond our control tips, trick & solutions science, evidence & guidance Dr Matt Wilson

More information

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia British Journal of Anaesthesia 98 (2): 241 5 (2007) doi:10.1093/bja/ael346 Advance Access publication January 8, 2007 OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

More information

CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour

CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour Dr Jason Reidy Nuffield Department of Anaesthetics Oxford University Hospitals CSE analgesia does not represent the gold standard

More information

Mitra et al. Sri Lankan Journal of Anaesthesiology: 23(2):61-65(2015) DOI: /slja.v23i2.8068

Mitra et al. Sri Lankan Journal of Anaesthesiology: 23(2):61-65(2015) DOI: /slja.v23i2.8068 DOI: 10.4038/slja.v23i2.8068 Evaluation of analgesic efficacy of the combination of fentanyl with low dose bupivacaine vs ropivacaine using patient controlled epidural analgesia for control of labour pain-

More information

Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C.

Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C. CSE s for Labor Analgesia PRO! Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C. Tsen, MD Director of

More information

Combined Spinal Epidural versus Epidural Labor Analgesia Mark C. Norris, M.D.,* Steven T. Fogel, M.D., Carol Conway-Long, R.N.

Combined Spinal Epidural versus Epidural Labor Analgesia Mark C. Norris, M.D.,* Steven T. Fogel, M.D., Carol Conway-Long, R.N. Anesthesiology 2001; 95:913 20 2001 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Combined Spinal versus Labor Analgesia Mark C. Norris, M.D.,* Steven T. Fogel, M.D.,

More information

COMPARISON OF INCREMENTAL SPINAL ANAESTHESIA USING A 32-GAUGE CATHETER WITH EXTRADURAL ANAESTHESIA FOR ELECTIVE CAESAREAN SECTION

COMPARISON OF INCREMENTAL SPINAL ANAESTHESIA USING A 32-GAUGE CATHETER WITH EXTRADURAL ANAESTHESIA FOR ELECTIVE CAESAREAN SECTION British Journal of Anaesthesia 1991; 66: 232-236 COMPARISON OF INCREMENTAL SPINAL ANAESTHESIA USING A 32-GAUGE CATHETER WITH EXTRADURAL ANAESTHESIA FOR ELECTIVE CAESAREAN SECTION I. G. KESTIN, A. P. MADDEN,

More information

A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center

A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center Research Article TheScientificWorldJOURNAL (2009) 9, 715 722 ISSN 1537-744X; DOI 10.1100/tsw.2009.94 A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics

More information

Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors

Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors Cristian Arzola MD MSc Department of Anesthesia and Pain Management Mount Sinai Hospital and University of

More information

OBSTETRICS Effects of intrathecal and i.v. small-dose sufentanil on the median effective dose of intrathecal bupivacaine for Caesarean section

OBSTETRICS Effects of intrathecal and i.v. small-dose sufentanil on the median effective dose of intrathecal bupivacaine for Caesarean section British Journal of Anaesthesia 98 (6): 792 6 (2007) doi:10.1093/bja/aem101 Advance Access publication May 3, 2007 OBSTETRICS Effects of intrathecal and i.v. small-dose sufentanil on the median effective

More information

Although intrathecal (IT) sufentanil provides effective

Although intrathecal (IT) sufentanil provides effective Combination of Intrathecal Sufentanil 10 g Plus Bupivacaine 2.5 mg for Labor Analgesia: Is Half the Dose Enough? Alex T. H. Sia, MMed, Jin L. Chong, MMed, and Jen W. Chiu, MMed Department of Anesthesia,

More information

Labor Epidural: Local Anesthetics and Beyond

Labor Epidural: Local Anesthetics and Beyond Goals: Labor Epidural: Local Anesthetics and Beyond Pedram Aleshi MD The Changing Practice of Anesthesia September 2012 Review Concept of MLAC Local anesthetic efficacy Local anesthetic sparing effects:

More information

LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR

LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR Henry Liu * 1,2, Shanglong Yao **1, Frank Rosinia *2 Abstract There is no

More information

Combined Spinal Epidural Technique for Labor Analgesia Does Not Delay Recognition of Epidural Catheter Failures

Combined Spinal Epidural Technique for Labor Analgesia Does Not Delay Recognition of Epidural Catheter Failures Combined Spinal Epidural Technique for Labor Analgesia Does Not Delay Recognition of Epidural Catheter Failures A Single-center Retrospective Cohort Survival Analysis Jessica M. Booth, M.D., Joshua C.

More information

Safety and quality of neuraxial analgesia. Ulla Sipiläinen HUCS Jorvi hospital

Safety and quality of neuraxial analgesia. Ulla Sipiläinen HUCS Jorvi hospital Safety and quality of neuraxial analgesia Ulla Sipiläinen 6.10. 2011 HUCS Jorvi hospital Chestnut s Checklist Preparation for neuraxial labor analgesia 1.Communicate (early) with obst provider review parturient

More information

Y. Lim, 1 A. T. Sia 2 and C. E. Ocampo 3

Y. Lim, 1 A. T. Sia 2 and C. E. Ocampo 3 Anaesthesia, 2006, 61, pages 339 344 doi:10.1111/j.1365-2044.2006.04535.x Comparison of computer integrated patient controlled epidural analgesia vs. conventional patient controlled epidural analgesia

More information

Original article Pravara Med Rev 2010; 2(3)

Original article Pravara Med Rev 2010; 2(3) Original article Pravara Med Rev 2010; 2(3) A randomized clinical trial to compare continuous epidural infusion technique with that of intermittent boluses for maintenance of epidural labour analgesia

More information

OB Div News March 2009

OB Div News March 2009 OB Div News March 2009 Several articles in this month s review have come from Canadian institutions. In spite of my pride in being Canadian, which was enhanced during the Olympics, this is purely coincidental.

More information

T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 )

T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 ) (Acta Anaesth. Belg., 2006, 57, 45-49) Ropivacaine versus Bupivacaine 0.125% with Fentanyl 1µg/ml for Epidural Labour Analgesia : Is Daily Practice More Important Than Pharmaceutical Choice? T. GIRARD

More information

An Epidural Initial Dose is Unnecessary in Combined Spinal Epidural Anesthesia for Caesarean Section

An Epidural Initial Dose is Unnecessary in Combined Spinal Epidural Anesthesia for Caesarean Section Original An Epidural Initial Dose is Unnecessary in Combined Spinal Epidural Anesthesia for Caesarean Section Takashi Hongo, Akira Kitamura, Motoi Yokozuka, Chol Kim and Atsuhiro Sakamoto Department of

More information

Continuous spinal analgesia via a spinal catheter

Continuous spinal analgesia via a spinal catheter Continuous Spinal Analgesia for Labor and Delivery: An Observational Study with a 23-Gauge Spinal Catheter Weike Tao, MD,* Erica N. Grant, MD, MSc,* Margaret G. Craig, MD,* Donald D. McIntire, PhD, and

More information

SURGICAL REMOVAL OF A LOOPED AND KNOTTED EPIDURAL CATHETER IN A POSTPARTUM PATIENT

SURGICAL REMOVAL OF A LOOPED AND KNOTTED EPIDURAL CATHETER IN A POSTPARTUM PATIENT SURGICAL REMOVAL OF A LOOPED AND KNOTTED EPIDURAL CATHETER IN A POSTPARTUM PATIENT - A Case Report - O. AL-KAYED *, F. AL-BOUTI **, AND M.O. ABABNEH *** Summary We report a case of unsuccessful removal

More information

Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany

Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany Kenneth E Nelson, M.D. Associate Professor Wake Forest University, North Carolina, USA Initiating

More information

David Gambling, MB, BS,* Jonathan Berkowitz, PhD, Thomas R. Farrell, MD, Alex Pue, MD,* and Dennis Shay, MD*

David Gambling, MB, BS,* Jonathan Berkowitz, PhD, Thomas R. Farrell, MD, Alex Pue, MD,* and Dennis Shay, MD* Society for Obstetric Anesthesia and Perinatology Section Editor: Cynthia A. Wong CME A Randomized Controlled Comparison of Epidural Analgesia and Combined Spinal-Epidural Analgesia in a Private Practice

More information

Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor

Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor A Randomized, Double-blind, Controlled Study Jessica L. Booth, M.D., Vernon H. Ross,

More information

Head Elevation in Spinal-Epidural Anesthesia Provides Improved Hemodynamics and Appropriate Sensory Block Height at Caesarean Section

Head Elevation in Spinal-Epidural Anesthesia Provides Improved Hemodynamics and Appropriate Sensory Block Height at Caesarean Section Original Article http://dx.doi.org/10.3349/ymj.2015.56.4.1122 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 56(4):1122-1127, 2015 Head Elevation in Spinal-Epidural Anesthesia Provides Improved Hemodynamics

More information

Pain Relief Options for Labor. Providing you with quality care, information and support

Pain Relief Options for Labor. Providing you with quality care, information and support Pain Relief Options for Labor Providing you with quality care, information and support What can I expect during my labor and delivery? As a patient in the Labor and Delivery suite at Lucile Packard Children

More information

Obstetrical Anesthesia. Safe Pain Relief for Childbirth

Obstetrical Anesthesia. Safe Pain Relief for Childbirth Obstetrical Anesthesia Safe Pain Relief for Childbirth Introduction Pain relief (analgesia) for labor and delivery is now safer than ever. In the United States approximately two-thirds of all women receive

More information

CSE for labour analgesia. Roshan Fernando: University College Hospital, London

CSE for labour analgesia. Roshan Fernando: University College Hospital, London CSE for labour analgesia Roshan Fernando: University College Hospital, London Lecture outline CSE labour analgesia: indications / technique advantages / disadvantages ambulation recent developments Techniques

More information

PAIN AND REGIONAL ANESTHESIA. Materials and Methods

PAIN AND REGIONAL ANESTHESIA. Materials and Methods PAIN AND REGIONAL ANESTHESIA Anesthesiology 2004; 101:439 44 2004 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Epidural Neostigmine Combined with Sufentanil Provides

More information

Induction position for spinal anaesthesia: Sitting versus lateral position

Induction position for spinal anaesthesia: Sitting versus lateral position 11 ORIGINAL ARTICLE Induction position for spinal anaesthesia: Sitting versus lateral position Khurrum Shahzad, Gauhar Afshan Abstract Objective: To compare the effect of induction position on block characteristics

More information

The Labour Epidural: Troubleshooting

The Labour Epidural: Troubleshooting O B S T E T R I C A N A E S T H E S I A Tutorial 366 The Labour Epidural: Troubleshooting Dr Charlotte Kingsley Anaesthetic Registrar, Royal Free Hospital, UK Dr Alan McGlennan Consultant Anaesthetist,

More information

Epidural Analgesia in Labor - Whats s New

Epidural Analgesia in Labor - Whats s New Epidural Analgesia in Labor - Whats s New Wichelewski Josef 821 Selective neural blockade has many clinical applications in medicine but nowhere has its use been so well accepted than in the field of Obstetrics.

More information

Combined Spinal epidural with Levobupivacaine or Ropivacaine with Fentanyl for Labor Analgesia: A Comparative Study

Combined Spinal epidural with Levobupivacaine or Ropivacaine with Fentanyl for Labor Analgesia: A Comparative Study ORIGINAL ARTICLE Combined Spinal epidural with Levobupivacaine or Ropivacaine 10.5005/jp-journals-10050-10080 with Fentanyl for Labor Analgesia Combined Spinal epidural with Levobupivacaine or Ropivacaine

More information

REGIONAL/LOCAL ANESTHESIA and OBESITY

REGIONAL/LOCAL ANESTHESIA and OBESITY REGIONAL/LOCAL ANESTHESIA and OBESITY Jay B. Brodsky, MD Stanford University School of Medicine Jbrodsky@stanford.edu Potential Advantages Regional compared to General Anesthesia Minimal intra-operative

More information

Case Report Caesarean Delivery Complicated by Unintentional Subdural Block and Conversion Disorder

Case Report Caesarean Delivery Complicated by Unintentional Subdural Block and Conversion Disorder Case Reports in Medicine Volume 2013, Article ID 751648, 4 pages http://dx.doi.org/10.1155/2013/751648 Case Report Caesarean Delivery Complicated by Unintentional Subdural Block and Conversion Disorder

More information

Epidural Analgesia: The Best Mix

Epidural Analgesia: The Best Mix Epidural Analgesia: The Best Mix Clinical Associate Professor Nolan McDonnell FANZCA MClinRes Department of Anaesthesia and Pain Medicine King Edward Memorial Hospital for Women Subiaco, Western Australia

More information

The Croatian viewpoint for labour analgesia and anaesthesia

The Croatian viewpoint for labour analgesia and anaesthesia Spring Congres of the Finish Society of Anaesthesiologist (Obstetric Anaesthesia branch, SOAT) The Croatian viewpoint for labour analgesia and anaesthesia Dragica Kopic,MD, Department of Anaesthesiology

More information

Parecoxib, Celecoxib and Paracetamol for Post Caesarean Analgesia: A Randomised Controlled Trial

Parecoxib, Celecoxib and Paracetamol for Post Caesarean Analgesia: A Randomised Controlled Trial Parecoxib, Celecoxib and Paracetamol for Post Caesarean Analgesia: A Randomised Controlled Trial McDonnell NJ, Paech MJ, Baber C, Nathan E Clinical Associate Professor Nolan McDonnell School of Medicine

More information

COMBINED SPINAL EPIDURAL ANAESTHESIA TECHNIQUE IN OBSTETRICS

COMBINED SPINAL EPIDURAL ANAESTHESIA TECHNIQUE IN OBSTETRICS COMBINED SPINAL EPIDURAL ANAESTHESIA TECHNIQUE IN OBSTETRICS Andre Van Zundert Catharina Hospital Eindhoven The Netherlands Introduction The combined spinal-epidural anesthesia technique (CSE) has been

More information

OBSTETRICS Effect of i.v. phenylephrine or ephedrine on the ED50 of intrathecal bupivacaine with fentanyl for Caesarean section

OBSTETRICS Effect of i.v. phenylephrine or ephedrine on the ED50 of intrathecal bupivacaine with fentanyl for Caesarean section OBSTETRICS Effect of i.v. phenylephrine or ephedrine on the ED50 of intrathecal bupivacaine with fentanyl for Caesarean section M. C. Hennebry 1, G. M. Stocks 1 *, P. Belavadi 1, J. Barnes 1,S.Wray 1,

More information

What s new in obstetric anesthesia?

What s new in obstetric anesthesia? SAOA 2013 - SPRING MEETING BERN What s new in obstetric anesthesia? PD Dr. Med Georges Savoldelli Médecin Adjoint Unité d anesthésiologie gynéco-obstétricale Service d Anesthésiologie, HUG An objectively

More information

Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial

Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial Surjeet Singh, 1 V.P. Singh, 2 Manish Jain, 3 Kumkum Gupta, 3 Bhavna Rastogi,

More information

INTRATHECAL FENTANYL ADDED TO LIDOCAINE FOR CESAREAN DELIVERY UNDER SPINAL ANESTHESIA

INTRATHECAL FENTANYL ADDED TO LIDOCAINE FOR CESAREAN DELIVERY UNDER SPINAL ANESTHESIA INTRATHECAL FENTANYL ADDED TO LIDOCAINE FOR CESAREAN DELIVERY UNDER SPINAL ANESTHESIA - A Randomised Clinical Trial - * AND KHOOSHIDEH M ** Abstract The addition of opioids to local anesthetics improves

More information

ASA Closed Claims Project: Regional Anesthesia Claims 1990 or later Lorri A. Lee MD Department of Anesthesiology University of Washington, Seattle, WA

ASA Closed Claims Project: Regional Anesthesia Claims 1990 or later Lorri A. Lee MD Department of Anesthesiology University of Washington, Seattle, WA ASA Closed Claims Project: Regional Anesthesia Claims 1990 or later Lorri A. Lee MD Department of Anesthesiology, Seattle, WA OVERVIEW 1. Closed Claims Project 2. Peripheral Nerve Blocks 3. Neuraxial Claims

More information

Regional Anaesthesia for Caesarean Section

Regional Anaesthesia for Caesarean Section Regional Anaesthesia for Caesarean Section "The Best Recipe" Warwick D. Ngan Kee Dept of Anaesthesia & Intensive Care The Chinese University of Hong Kong What I will not do. Magic recipes One shoe to fit

More information

Intraspinal (Neuraxial) Analgesia Community Nurses Competency Test

Intraspinal (Neuraxial) Analgesia Community Nurses Competency Test Intraspinal (Neuraxial) Analgesia Community Nurses Competency Test 1 Intraspinal (Neuraxial) Analgesia for Community Nurses Competency Test 1) Name the two major classifications of pain. i. ii. 2) Neuropathic

More information

What s New in Post-Cesarean Analgesia?

What s New in Post-Cesarean Analgesia? Anesthesia & Obstetrics What s New in Post-Cesarean Analgesia? October 23rd, 2013 2013 UCSF What Does The Evidence Tell Us? Mark Rollins, MD, PhD UC SF Post-Delivery Pain (Mean pain scores for first 24

More information

Trust Guideline for the Management of Inadvertent Dural Puncture and Post Dural Puncture Headache in Obstetrics

Trust Guideline for the Management of Inadvertent Dural Puncture and Post Dural Puncture Headache in Obstetrics A clinical guideline recommended for use In: By: For: Key words: Written by: Delivery Suite All Anaesthetic Staff Women in labour who have had an inadvertent dural puncture when having an epidural sited

More information

EPIDURAL ANALGESIA FOR THE SURGICAL INDUCTION OF LABOUR

EPIDURAL ANALGESIA FOR THE SURGICAL INDUCTION OF LABOUR Br. J. Anaesth. (1974), 46, 747 EPIDURAL ANALGESIA FOR THE SURGICAL INDUCTION OF LABOUR N. G. CASEBY SUMMARY Surgical induction of labour was performed on 80 patients under epidural analgesia and on 73

More information

COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL

COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL Faraz Shafiq *, Mohammad Hamid ** and Khalid Samad *** Introduction Epidural

More information

VARIATIONS IN THE FLOW OF CEREBROSPINAL FLUID THROUGH SPINAL NEEDLES

VARIATIONS IN THE FLOW OF CEREBROSPINAL FLUID THROUGH SPINAL NEEDLES Br. J. Anaesth. (1987), 59, 1465-1471 VARIATIONS IN THE FLOW OF CEREBROSPINAL FLUID THROUGH SPINAL NEEDLES S. P. GERRISH AND J. E. PEACOCK The use of intrathecal drugs to produce either analgesia or anaesthesia

More information

Insertion of an intrathecal catheter following accidental dural puncture: a meta-analysis

Insertion of an intrathecal catheter following accidental dural puncture: a meta-analysis International Journal of Obstetric Anesthesia (2013) 22, 26 30 0959-289X/$ - see front matter c 2012 Elsevier Ltd. All rights reserved. http://dx.doi.org/10.1016/j.ijoa.2012.10.004 REVIEW ARTICLE Insertion

More information

Epidural Catheter Penetration of Human Dural Tissue

Epidural Catheter Penetration of Human Dural Tissue Anesthesiology 2004; 100:1491 6 2004 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Epidural Catheter Penetration of Human Dural Tissue In Vitro Investigation Pamela J.

More information

Effects of IV Ondansetron during spinal anaesthesia with Ropivacaine and Fentanyl

Effects of IV Ondansetron during spinal anaesthesia with Ropivacaine and Fentanyl Original article Effects of IV Ondansetron during spinal anaesthesia with Ropivacaine and Fentanyl 1Dr Bipul Deka, 2 Dr Bharat Talukdar, 3 Dr. Amal Kumar Laha, 4 Dr. Rupak Bhattacharjee 1Assistant Professor,

More information

Eldor Epidural Kit (CSEN 68) Epidural catheter technique

Eldor Epidural Kit (CSEN 68) Epidural catheter technique Eldor Epidural Kit (CSEN 68) Epidural catheter technique Using the epidural needle the epidural space is reached by the loss of resistance technique or the hanging drop technique, while the proximal opening

More information

COMPARISON OF THE EFFECT OF TWO DIFFERENT DOSES OF 0.75% GLUCOSE-FREE ROPIVACAINE FOR SPINAL ANESTHESIA FOR LOWER LIMB AND LOWER ABDOMINAL SURGERY

COMPARISON OF THE EFFECT OF TWO DIFFERENT DOSES OF 0.75% GLUCOSE-FREE ROPIVACAINE FOR SPINAL ANESTHESIA FOR LOWER LIMB AND LOWER ABDOMINAL SURGERY Two doses of ropivacaine for spinal anesthesia COMPARISON OF THE EFFECT OF TWO DIFFERENT DOSES OF.75% GLUCOSE-FREE ROPIVACAINE FOR SPINAL ANESTHESIA FOR LOWER LIMB AND LOWER ABDOMINAL SURGERY John On-Nin

More information

Combined spinal-epidural versus epidural analgesia in labour (Review)

Combined spinal-epidural versus epidural analgesia in labour (Review) Combined spinal- versus analgesia in labour (Review) Simmons SW, Cyna AM, Dennis AT, Hughes D This is a reprint of a Cochrane review, prepared and maintained by The Cochrane Collaboration and published

More information

Combined spinal-epidural analgesia represents the gold standard for regional analgesia in labour

Combined spinal-epidural analgesia represents the gold standard for regional analgesia in labour Combined spinal-epidural analgesia represents the gold standard for regional analgesia in labour Felicity Plaat Queen Charlotte s Hospital, Imperial College NHS Trust London Combined spinal-epidural analgesia

More information

Case Discussions Cynthia A. Wong, M.D.

Case Discussions Cynthia A. Wong, M.D. Case Discussions Cynthia A. Wong, M.D. Association des Anesthѐsiologistes du Quѐbec April 2014 CASE 1 Maternal Mortality Lewis G (ed). CEMACH 2007. Saving Mothers Lives 2003-2005 Pregnancy Complications

More information

PATIENT CARE MANUAL POLICY

PATIENT CARE MANUAL POLICY PATIENT CARE MANUAL POLICY NUMBER VII-A-15 PAGE 1 OF 3 APPROVED BY: CATEGORY: Vice President and Senior Operating Officer; Rural Health Services & Professional Practice Lead Body Systems; Central Nervous

More information

Beneficial effects of the addition of intrathecal fentanyl to bupivacaine for spinal anesthesia in cesarean section

Beneficial effects of the addition of intrathecal fentanyl to bupivacaine for spinal anesthesia in cesarean section Anesth Pain Med 2017; 12: 233-239 https://doi.org/10.17085/apm.2017.12.3.233 Clinical Research http://crossmark.crossref.org/dialog/?doi=10.17085/apm.2017.12.3.233&domain=pdf&date_stamp=2017-07-25 pissn

More information

Postoperative epidural analgesia using local anesthetic

Postoperative epidural analgesia using local anesthetic REGIONAL ANESTHESIA SECTION EDITOR DENISE J. WEDEL A Comparison of 0.1% and 0.2% Ropivacaine and Bupivacaine Combined with Morphine for Postoperative Patient-Controlled Epidural Analgesia After Major Abdominal

More information

WITH ISOBARIC BUPIVACAINE (5 MG/ML)

WITH ISOBARIC BUPIVACAINE (5 MG/ML) , 49, 2013, 3 63 (5 MG/ML) (5 MG/ML).,.,.,..,..,, SPINAL ANESTHESIA: COMPARISON OF ISOBARIC ROPIVACAINE (5 MG/ML) WITH ISOBARIC BUPIVACAINE (5 MG/ML) D. Tzoneva, Vl. Miladinov, Al. Todorov, M. P. Atanasova,

More information

Closed-loop Double-pump Automated System Manual Boluses

Closed-loop Double-pump Automated System Manual Boluses Closed-loop Double-pump Automated System versus Manual Boluses to treat Hypotension during Spinal Anaesthesia for Caesarean Section: randomised controlled trial Dr. Ban Leong SNG MBBS, MMED, FANZCA, FFPMANZCA,

More information

Although epidural bupivacaine is highly effective

Although epidural bupivacaine is highly effective Original Article 286 Comparison between 0.08% Ropivacaine and 0.06% Levobupivacaine for Epidural Analgesia during Nulliparous Labor: A Retrospective Study in A Single Center Hui-Ling Lee, MD; Liang-Ming

More information

Postdural puncture headache preventing the impossible, treating the symptoms, evaluating long term effects.

Postdural puncture headache preventing the impossible, treating the symptoms, evaluating long term effects. Postdural puncture headache preventing the impossible, treating the symptoms, evaluating long term effects. Marc Van de Velde, MD, PhD Professor of Anaesthesia, Catholic University Leuven (KUL) Chair Department

More information

Bupivacaine concentrations in lumbar cerebrospinal fluid in patients with failed spinal anaesthesia

Bupivacaine concentrations in lumbar cerebrospinal fluid in patients with failed spinal anaesthesia British Journal of Anaesthesia 102 (6): 839 44 (2009) doi:10.1093/bja/aep050 Advance Access publication March 26, 2009 Bupivacaine concentrations in lumbar cerebrospinal fluid in patients with failed spinal

More information

Managing Epidural and Spinal Failures. Ki Jinn Chin, MBBS (Hons), MMed, FRCPC Associate Professor Toronto Western Hospital University of Toronto

Managing Epidural and Spinal Failures. Ki Jinn Chin, MBBS (Hons), MMed, FRCPC Associate Professor Toronto Western Hospital University of Toronto Managing Epidural and Spinal Failures Ki Jinn Chin, MBBS (Hons), MMed, FRCPC Associate Professor Toronto Western Hospital University of Toronto How often do we fail? How common is failure? Incidence varies

More information

EFFECTS OF POSTURE AND BARICITY ON SPINAL ANAESTHESIA WITH 0.5 % BUPIVACAINE 5 ML

EFFECTS OF POSTURE AND BARICITY ON SPINAL ANAESTHESIA WITH 0.5 % BUPIVACAINE 5 ML Br.J. Anaesth. (1988), 61, 139-143 EFFECTS OF POSTURE AND BARICITY ON SPINAL ANAESTHESIA WITH 0.5 % BUPIVACAINE 5 ML A Double-Blind Study R. W. D. MITCHELL, G. M. R. BOWLER, D. B. SCOTT AND H. H. EDSTROM

More information

Epidural Administration of Neostigmine and Clonidine to Induce Labor Analgesia

Epidural Administration of Neostigmine and Clonidine to Induce Labor Analgesia Anesthesiology 2005; 102:1205 10 2005 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Epidural Administration of Neostigmine and Clonidine to Induce Labor Analgesia Evaluation

More information

Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia

Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia ISPUB.COM The Internet Journal of Anesthesiology Volume 33 Number 1 Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia S Gautam, S Singh, R Verma, S Kumar,

More information

Remifentanil PCA In Labor

Remifentanil PCA In Labor Remifentanil PCA In { Jennifer Lucero, MD Clinical Instructor UCSF Department of Anesthesia Remifentanil PCA in Discuss the Pharmokinectics of Remifentanil Review literature on the use of Remifentanil

More information

Guidelines for the Conduct of Epidural Analgesia for Parturients

Guidelines for the Conduct of Epidural Analgesia for Parturients Page 1 of 6 Guidelines for the Conduct of Epidural Analgesia for Version Effective Date 1 Feb 1993 (Reviewed Feb 2002) 2 Oct 2012 Document No. HKCA P4 v2 Prepared by College Guidelines Committee Endorsed

More information

Int J Clin Exp Med 2018;11(8): /ISSN: /IJCEM

Int J Clin Exp Med 2018;11(8): /ISSN: /IJCEM Int J Clin Exp Med 2018;11(8):8003-8010 www.ijcem.com /ISSN:1940-5901/IJCEM0078281 Original Article Efficacy and side effects comparison of bupivacaine and ropivacaine with fentanyl for labor analgesia

More information

Comparision of Intravenous Bolus Phenylephrine and Ephedrine for Prevention of Post Spinal Hypotension in Cesarean Sections

Comparision of Intravenous Bolus Phenylephrine and Ephedrine for Prevention of Post Spinal Hypotension in Cesarean Sections IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 14, Issue 7 Ver. II (July. 2015), PP 99-103 www.iosrjournals.org Comparision of Intravenous Bolus Phenylephrine

More information

Spread of subarachnoid hyperbaric amethocaine in adolescents

Spread of subarachnoid hyperbaric amethocaine in adolescents British Journal of Anaesthesia 1995; 74: 41-45 Spread of subarachnoid hyperbaric amethocaine in adolescents Y. HIRABAYASHI, R. SHIMIZU, K. SAITOH, H. FUKUDA Summary We have compared the spread of subarachnoid

More information

Neuraxial anesthesia for scoliosis and previous spinal surgery in pregnancy

Neuraxial anesthesia for scoliosis and previous spinal surgery in pregnancy O B S T E T R I C A N A E S T H E S I A Tutorial 350 Neuraxial anesthesia for scoliosis and previous spinal surgery in pregnancy Dr. Isabella Rossi Anesthesiology resident, Barnes-Jewish Hospital, USA

More information

Pain Relief During Labor

Pain Relief During Labor UW MEDICINE PATIENT EDUCATION Pain Relief During Labor Common pain relief options This chapter explains common pain relief options used during labor and delivery, when and how they are used, and what the

More information

COMBINED SPINAL AND EPIDURAL ANAESTHESIA (CSEA) USING SEPARATE INTERSPACE TECHNIQUE

COMBINED SPINAL AND EPIDURAL ANAESTHESIA (CSEA) USING SEPARATE INTERSPACE TECHNIQUE COMBINED SPINAL AND EPIDURAL ANAESHESIA (CSEA) USING SEPARAE INERSPACE ECHNIQUE Shreepathi Krishna Achar* 1, Vinoda Venkata Rao Assistant Professor, Department of Anaesthesiology, Kasturba Medical College,

More information

Assistant Professor, Anaesthesia Department, Govt. General Hospital / Guntur Medical College, Guntur, Andhra Pradesh, India.

Assistant Professor, Anaesthesia Department, Govt. General Hospital / Guntur Medical College, Guntur, Andhra Pradesh, India. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 15, Issue 8 Ver. I (August. 2016), PP 87-91 www.iosrjournals.org A Comparative Study of 0.25% Ropivacaine

More information

Impact of Baricity of Bupivacaine on Intrathecal Fentanyl- Associated Pruritus during Combined Spinal/Epidural Anesthesia for Labor

Impact of Baricity of Bupivacaine on Intrathecal Fentanyl- Associated Pruritus during Combined Spinal/Epidural Anesthesia for Labor ISPUB.COM The Internet Journal of Anesthesiology Volume 20 Number 1 Impact of Baricity of Bupivacaine on Intrathecal Fentanyl- Associated Pruritus during Combined Spinal/Epidural Anesthesia for Labor R

More information

Uneventful recovery following accidental epidural injection of dobutamine

Uneventful recovery following accidental epidural injection of dobutamine 1 Case report Uneventful recovery following accidental epidural injection of dobutamine Bastiaan M. Gerritse, M.D., Ph.D., Daan de Vos, R.N.A, Anton W. Visser, M.D., Ph.D. Department of Anesthesiology,

More information

PAIN AND REGIONAL ANESTHESIA

PAIN AND REGIONAL ANESTHESIA PAIN AND REGIONAL ANESTHESIA Anesthesiology 2007; 106:149 56 Copyright 2006, the American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Determination of the Full Dose Response

More information

Patient-controlled analgesia: epidural fentanyl and i.v. morphine compared after Caesarean section

Patient-controlled analgesia: epidural fentanyl and i.v. morphine compared after Caesarean section British Journal of Anaesthesia 82 (3): 366 70 (1999) Patient-controlled analgesia: epidural fentanyl and i.v. morphine compared after Caesarean section D. W. Cooper, U. Saleh, M. Taylor, S. Whyte, D. Ryall,

More information

The spinal headache in pregnant women

The spinal headache in pregnant women N. J. Obstet. Gynaecol Vol. 1, No. 2, p. 4-9 Nov-Dem 2006 REVIEW The spinal headache in pregnant women Krzysztof M. Kuczkowski Departments of Anesthesiology and Reproductive Medicine, University of California,

More information

Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section

Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section The Journal of International Medical Research 2012; 40: 1099 1107 Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section SW FENG,

More information

REGIONAL ANAESTHESIA Bupivacaine concentrations in the lumbar cerebrospinal fluid of patients during spinal anaesthesia

REGIONAL ANAESTHESIA Bupivacaine concentrations in the lumbar cerebrospinal fluid of patients during spinal anaesthesia REGIONAL ANAESTHESIA Bupivacaine concentrations in the lumbar cerebrospinal fluid of patients during spinal anaesthesia W. Ruppen 1, L. A. Steiner 1,J.Drewe 2, L. Hauenstein 23, S. Brugger 1 and M. D.

More information

Faculty Development Talk

Faculty Development Talk Faculty Development Talk Updates in Obstetric Anaesthesia Leong Wan Ling Consultant, Women s Anaesthesia, KK Women s & Children s Hospital 13 th September 2017 Topics Labour ward Neuraxial anaesthesia

More information

Pharmacologic Pain Relief: It s Use in Labor. Linda Robinson MSN, RNC Clinical Nurse Specialist, Northwest Hospital Spring, 2016

Pharmacologic Pain Relief: It s Use in Labor. Linda Robinson MSN, RNC Clinical Nurse Specialist, Northwest Hospital Spring, 2016 Pharmacologic Pain Relief: It s Use in Labor Linda Robinson MSN, RNC Clinical Nurse Specialist, Northwest Hospital Spring, 2016 Objectives Recognize common medications used in the management of labor pain

More information

Spinal anesthesia without hypotension a myth or reality?

Spinal anesthesia without hypotension a myth or reality? Spinal anesthesia without hypotension a myth or reality? Peter Poredoš, MD, PhD, DESA peter.poredos@kclj.si University Medical Centre Ljubljana, Slovenia Department for Anesthesiology and Intensive Care

More information

Tripler Army Medical Center Obstetric Anesthesia Service - FAQs

Tripler Army Medical Center Obstetric Anesthesia Service - FAQs Tripler Army Medical Center Obstetric Anesthesia Service - FAQs What is a labor epidural? A labor epidural is a thin tube (called an epidural catheter) placed in a woman s lower back by an anesthesia provider.

More information

Post-dural puncture headache in pregnant women: What have we learned?

Post-dural puncture headache in pregnant women: What have we learned? Rev. Col. Post-dural Anest. 34: puncture 267-272, headche 2006 ARTÍCULO DE REVISIÓN Post-dural puncture headache in pregnant women: What have we learned? Krzysztof M. Kuczkowski, M.D.* ABSTRACT: The obstetric

More information

Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent

Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent British Journal of Anaesthesia 1997; 78: 493 497 CLINICAL INVESTIGATIONS Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent G. LYONS, M. COLUMB, L. HAWTHORNE

More information

COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR

COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR Br.J. Anaesth. (1977), 49, 75 COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR D. G. LITTLEWOOD, D. B. SCOTT, J. WILSON AND B. G. COVINO SUMMARY Various

More information

Factors in patient dissatisfaction and refusal regarding spinal anesthesia

Factors in patient dissatisfaction and refusal regarding spinal anesthesia Clinical Research Article Korean J Anesthesiol 2010 October 59(4): 260-264 DOI: 10.4097/kjae.2010.59.4.260 Factors in patient dissatisfaction and refusal regarding spinal anesthesia Won Ji Rhee, Chan Jong

More information