BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.
|
|
- Kimberly Boyd
- 5 years ago
- Views:
Transcription
1 BIO-LOGIC NAVIGATOR PRO TRUSTED TECHNOLOGY. RELIABLE RESULTS.
2 THE BIO-LOGIC NAVIGATOR PRO SYSTEM DELIVERS A RELIABLE AND ACCURATE DIAGNOSTIC EVOKED POTENTIAL TESTING PLATFORM WITH AN ADAPTABLE DESIGN FOR SATISFYING CURRENT AND FUTURE CLINICAL NEEDS.
3 THE BIO-LOGIC NAVIGATOR PRO AEP SYSTEM IS FLEXIBLE, PORTABLE AND ADAPTABLE, PROVIDING RESULTS YOU CAN TRUST. DESIGNED BY AUDIOLOGISTS TO CONTINUOUSLY ADAPT TO EVOLVING CLINICIAN AND PATIENT NEEDS The Bio-logic Navigator Pro system offers a full range of AEP functionality. Portable and light weight Multiple waveform display configurations Active data analysis during collection Continuous EEG display Customizable protocols and reports Windows 7 compatible Multiple protocols available or create your own Dual, scrolling displays for unlimited waveforms FULL AEP FUNCTIONALITY INCLUDES: Click evoked ABR Tone burst ABR Electocochleography (ECochG)* Middle and late latency response (MLR, ALR) P300 Electrical ABR (EABR)* Vestibular Evoked Myogenic Potential (VEMP)** *required cables available at additional cost **not available in the U.S. Screening ABR Screening OAE Diagnostic DPOAE Diagnostic TEOAE Input/Output OAE functions MASTER II Auditory Steady State Response Electroneuronography (facial nerve testing) Vestibular Evoked Myogenic Potential Test**
4 THE BIO-LOGIC NAVIGATOR PRO AEP SYSTEM DESIGNED BY AUDIOLOGISTS FOR AUDIOLOGISTS. One small package meeting your needs... ADVANCED DATA COLLECTION AND ANALYSIS FEATURES Automatic electrode switching eliminating the need to manually switch electrodes during testing Residual noise calculation and Fsp optimizing response detection Waveforms saved automatically no lost data Flexible data analysis mark and compare waveforms during collection Collection protocols select from several built in protocols with commonly used parameters or easily create your own Quantifiable reproducibility mathematically correlate waveforms to ensure reliability GraphMaster create charts to compare latencies to published age referenced normative data FLEXIBLE REPORT SOFTWARE Save reports as pdf file allowing for simple transfer to the patient s electronic medical record (EMR) Customizable report templates creating professional reports to meet the needs of your practice Comprehensive patient database allowing for creation of optional folders to organize patient records Auditory Evoked Potentials Page 1 San Diego Medical Center Department of Audiology 500 Harbor Drive San Diego, CA Patient: ID#: 2 channel, AC Click Adult Neuro Gender: Birth date: 1/1/2000 Test Date: 3/23/ :54:48 AM Physician: A. B. Aare, MD Tested by: Mary Ormson, AuD History: This patient was referred by Dr. Aare for a neurodiagnostic ABR evaluation. He was previously seen in our office for a full audiologic workup, including pure tone audiometry and impedance testing. All results were within normal limits, consistent with normal hearing thresholds and normal middle ear compliance and pressure. Ipsilateral and contralateral acoustic reflexes were within normal limits in each ear, with no evidence of reflex decay. Medical history is significant for high blood pressure for which the patient is taking medication. He reports difficulty with balance, which was first noticed approximately one month after he bagan taking his blood pressure medication. There is no history of falls. He is able to work at his present job with no accommodations. He is able to drive and to complete most activities in his home without difficulty. Page 2 Results and Recommendations: Patient: ID#: Tested by: 2 channel, AC Click Adult Neuro Mary Ormson, AuD Gender: Birth date: 1/1/2000 Test Date: 3/23/ :54:48 AM Physician: A. B. Aare, MD The ABR was recorded using a 4 electrode array and two channel recording to measure ipsilateral and contralateral responses. An 80dBnHL, 10.9 click per second rarefaction stimulus was presented to each ear individually through standard insert earphones. The absolute and interpeak latencies are within 2 standard deviations of the age-referenced normal values, bilaterally. Waveform morphology and reproducibility is excellent. There are no significant interaural latency differences noted. Test results are consistent with normal brainstem conduction and no retrocochlear pathology for each ear. Recommendations include returning to the referring physician for continued followup. Further evaluation to address the complaints of imbalance might include CDP with the NeuroCom SMART EquiTest to evaluate functional postural control, as well as VNG to assess the possibility of peripheral vestibular hypofunction. Latencies (ms) Label Index I II III IV V Interlatencies (ms) Label Index I-III III-V I-V A A B B
5 THE BIO-LOGIC NAVIGATOR PRO FAMILY OF PRODUCTS. AEP Standard auditory evoked potentials including ABR, ECochG, MLR, ALR, P300 and EABR Scout Full range of OAE test capability including DPOAE and TEOAE ABaer Newborn hearing screening system including ABR, DPOAE and TEOAE MASTER II Multiple Auditory Steady-State Evoked Response (ASSR) technology ENoG External SEP stimulator option supports electroneuronography VEMP* EMG rectification for Vestibular Evoked Myogenic Potential test *Not available in the U.S. Scout ABaer MASTER II ENoG VEMP
6 Natus Medical Incorporated Register for the Neonatal Care Academy at for expanded educational courses & more 2017 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates. P/N D
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300 Neuro-Audio one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA) (air and
More informationNeuro-Audio Version 2010
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE ECochG MLR P300 Neuro-Audio Version 2010 one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA)
More informationEPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE
EPIC-PLUS System for auditory evoked potentials and neuro-otology PEA - VEMPs ASSR - E-ABR FACIAL NERVE EPIC-PLUS System for auditory evoked potentials and neuro-otology Epic-plus, a unique solution. With
More informationThe Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems
Authored by: Whenever faced with purchasing new equipment, the makes and models on the market can be confusing. It helps to know some basics, what comparable products are on the market, and what each of
More informationThe Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform
The Eclipse Designed to meet your every need AEP, ASSR, VEMP & OAE testing on one dedicated platform Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile platform.
More informationThe Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform
The Eclipse High quality evoked potentials at your command AEP, ASSR, & OAE testing on one dedicated platform Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile
More informationScience made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Science made smarter Titan Advanced made flexible Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Audiometry Tympanometry ABR OAE Hearing Aid Fitting Balance Let
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The first and only one of its kind 4
More informationCE-Chirp. Making ABR fast, accurate and clear! Stimulus Family
Making ABR fast, accurate and clear! Response amplitudes typically 50% larger than tone burst responses, with the potential to halve the test time CE-Chirp Stimulus Family The Gold standard for threshold
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationIII. Comprehensive. Efficient. Auditory EP Testing
V I III Comprehensive. Efficient. Auditory EP Testing Fast, Flexible and User-Friendly Efficient workflow = Focus on the patient The intuitive software and streamlined interpretation with normative data
More informationEclipse Evoked Potential System. 10 reasons to choose
Eclipse Evoked Potential System 10 reasons to choose Database NOAH OtoAccess TM OAE Data Storage & Sharing Data Storage & Sharing ABR DPOAE EP25 Screening and clinical DPOAE ABR, MLR, LLR, P300, MMN, ECochG
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device. Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationGRASON-STADLER HEARING ASSESSMENT SYSTEMS
Audiometric Solutions GRASON-STADLER HEARING ASSESSMENT SYSTEMS Setting The Clinical Standard Audiometric Solutions GRASON-STADLER HEARING ASSESSMENT SYSTEMS Clinical Systems GSI Audiostar Pro GSI AudioStar
More informationUPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS
UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS Why do we need frequency-specific stimuli? Percent of Audiograms 50 Pittman & Stelmachowicz (2002) 40 30 20 10 Adults Children 0
More informationSLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;
1 SLHS 588A Electrophysiologic Assessment Techniques: FALL 2013 Barbara Cone-Wesson, Ph.D. 521 SLHS, Tel: 626-3710 email: conewess@email.arizona.edu Office hours: open door policy Class Meeting: Room 229-SLHS,
More informationJames W. Hall III, Ph.D.
Application of Auditory Steady State Response (ASSR) in Diagnosis of Infant Hearing Loss in the Era of Universal Newborn Hearing Screening James W. Hall III, Ph.D. Clinical Professor and Chair Department
More informationNEURO-AUDIO. Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research
NEURO-AUDIO Clinical ABR & OAE Analyzer, Screening Audiometer US-EDITION Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit Complete solu on: screening, diagnos cs, research High quality of
More informationPERIPHERAL AND CENTRAL AUDITORY ASSESSMENT
PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT Ravi Pachigolla, MD Faculty Advisor: Jeffery T. Vrabec, MD The University of Texas Medical Branch At Galveston Department of Otolaryngology Grand Rounds Presentation
More informationContents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface
Contents Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface ix xi Rationale for Objective Hearing Assessment 1 A Word about Terminology 1 Important Terms and Concepts
More informationAudiology Core Competencies Worksheet
Audiology Core Competencies Worksheet The Audiology Core Competencies worksheet is a reference document to guide expectations related to the expected level of competence prior to the initiation of the
More informationThe following describes general use of ELIOS device
General use of the device The following describes general use of ELIOS device 1. Introduction of graphical user interface Presence indicator of SD card Charging indicator General Informations Screen title
More informationAudiological Diagnosis after Newborn Screening
Audiological Diagnosis after Newborn Screening Pr Hung THAI-VAN, M.D., Ph.D. President of the French Society of Audiology Department of Audiology & Otoneurological Evaluation (Head) Lyon University Hospital
More informationAdvanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!
Advanced The all in one instrument for OAE, ABR, ASSR and Audiometry Advanced the modular approach! Designed, engineered and made in Germany. Configure your system with a choice of modules: TEOAE, DPOAE,
More informationBut, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??
1 Auditory Steady State Response (ASSR) thresholds have been shown to be highly correlated to bh behavioral thresholds h in adults and older children with normal hearing or those with sensorineural hearing
More informationA full product range for your every need. World leading diagnostic solutions
A full product range for your every need World leading diagnostic solutions Future-safe solutions based on knowledge For more than 45 years, Interacoustics has helped the professional world reach new milestones
More informationABR assesses the integrity of the peripheral auditory system and auditory brainstem pathway.
By Prof Ossama Sobhy What is an ABR? The Auditory Brainstem Response is the representation of electrical activity generated by the eighth cranial nerve and brainstem in response to auditory stimulation.
More informationAccuScreen ABR Screener
AccuScreen ABR Screener Test Methods Doc no. 7-50-1015-EN/02 0459 Copyright notice No part of this Manual or program may be reproduced, stored in a retrieval system, or transmitted, in any form or by any
More informationTHRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS
THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST ABR IN DIFFERENT AUDIOMETRIC CONFIGURATIONS INTRODUCTION INTRODUCTION Evoked potential testing is critical in the determination of audiologic thresholds
More informationKANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT
KANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT SoundBeginnings Early Hearing Detection and Intervention Program Kansas Department of Health & Environment 1000 SW Jackson Ste. 220 Topeka, Kansas 66612-1274
More informationNEURO-AUDIO. Auditory EP (ABR, VEMP, ASSR, ECochG) and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research
NEURO-AUDIO Clinical ABR & OAE Analyzer, Screening Audiometer Auditory EP (ABR, VEMP, ASSR, ECochG) and OAE tes ng in one unit Complete solu on: screening, diagnos cs, research High quality of recording
More informationUpdates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)
Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG) Introduction This document is intended to update and
More informationOPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS
OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS AUDITORY BRAINSTEM RESPONSE (ABR) IN CLINICAL PRACTICE Leigh Biagio de Jager Auditory Evoked Potentials (AEPs) are not measures of
More informationthe truly automated all-in-one hearing screener
the truly automated all-in-one hearing screener ONLY THE ECHO-SCREEN HEARING SCREENER COMBINES ADVANCED TEOAE, DPOAE AND AABR TECHNOLOGIES WITH FULLY AUTOMATED RESULTS AND COMPLETELY STANDARDIZED, PRE-
More informationEvoked Potenital Reading Session: BAEPs
Evoked Potenital Reading Session: BAEPs Alan D. Legatt, M.D., Ph.D. Disclosures relevant to this presentation: None AEP Components on a Logarithmic Time Scale Source: Picton TW, Hillyard SA. Human auditory
More informationQUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )
QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING (8-04-15907 and 8-04-15908) DEVICE CONNECTORS On/off button Headphones Power supply Air pump USB cable START MENU CONFIRM PRESET Label printer
More informationSpeech Therapists and Audiologists 2007
Speech Therapists and Audiologists 2007 NATIONAL REFERENCE PRICE LIST FOR SERVICES BY SPEECH THERAPISTS AND AUDIOLOGISTS, EFFECTIVE FROM 1 JANUARY 2007 The following reference price list is not a set of
More informationWheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O
Copyright 2007 by Wheeler, K.S. Critical Review: Is there evidence that auditory steady-state response measures provide a more accurate electrophysiological estimate of behavioural thresholds in infants
More informationEvoked Potenital Reading Session: BAEPs
Evoked Potenital Reading Session: BAEPs Alan D. Legatt, M.D., Ph.D. Disclosures relevant to this presentation: None AEP Components on a Logarithmic Time Scale Source: Picton TW, Hillyard SA. Human auditory
More informationthe truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines
the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines advanced TEOAE, DPOAE and AABR technologies with fully automated results and completely standardized, pre-
More informationGSI AUDIOscreener OAE AND ABR HEARING SCREENING
GSI AUDIOscreener OAE AND ABR HEARING SCREENING + Setting The Clinical Standard GSI AUDIOscreener OAE AND ABR HEARING SCREENING + The Problem Hearing loss is the most common birth defect in the United
More informationEmissions are low-intensity sounds that may be detected in the external ear canal by a microphone
OAEs Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone OAE is a pre-neural phenomenon They can be measured even when the 8 th cranial nerve is severely damaged
More informationAUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES
Last modified 12/08/02 www.nhsp.info/workbook.shtml Page 1 of 5 NEONATAL HEARING SCREENING AND ASSESSMENT AUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES
More informationQuick Guide - eabr with Eclipse
What is eabr? Quick Guide - eabr with Eclipse An electrical Auditory Brainstem Response (eabr) is a measurement of the ABR using an electrical stimulus. Instead of a traditional acoustic stimulus the cochlear
More informationGeneral Catalogue. Product Line for Hearing Screening & Diagnostics
General Catalogue Product Line for Hearing Screening & Diagnostics Welcome to the World of MAICO International Sales Team Andreas Kurzbuch Angela Röske Anke Trey Daniel Herrle Melanie Pérez Salas Nadine
More informationUser Manual. Neuro-Audio.NET UM ( )
User Manual Neuro-Audio.NET UM032.01.004.000 (12.10.2010) Neurosoft Ltd. 2012 5, Voronin str., Ivanovo, 153032, Russia P.O. Box 10, Ivanovo, 153000, Russia Phone: +7 (4932) 24-04-34 Fax: +7 (4932) 24-04-35
More informationQUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)
DEVICE CONNECTORS On/off button Power supply USB cable Headphones or second transducer Air pump USB Label Patient response Probe cable printer button START MENU Please note that not all Start Menu options
More information(Otoacoustic Emissions and Automated ABR)
An Overview of the technologies used in NHS / UNHS (Otoacoustic Emissions and Automated ABR) IAPA & EANO Joint Congress June 2-5,Porto Carras, Halkidiki-Thesaloniki, Greece Contents of the Lecture Part
More informationTechnical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa
J Am Acad Audiol 20:306 310 (2009) Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: 10.3766/jaaa.20.5.3 Shlomo Silman*{{ Michele B. Emmer*{ Carol A.
More informationHearing Screening, Diagnostics and Intervention
JCIH Newborn Hearing Screening Guidelines 1-3-6 Model By 1 month Screenhearing Hearing Screening, Diagnostics and Intervention By 3 months: Evaluate hearing and complete diagnosticaudiology and otolaryngology
More informationOAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols
Screener PLUS with 4 frequency DPOAE testing Protocols Diagnostic PLUS with 4, 6 and 12 frequency DPOAE testing Protocols *TEOAE upgrade OAE Test System Physicians Otoacoustic emissions testing is an ideal
More informationAUDITORY STEADY STATE RESPONSE (ASSR)
AUDITORY STEADY STATE RESPONSE (ASSR) Introduction A far-field evoked auditory potential test Principle Similarity to ABR o Sound stimulus converted to electrical impulse pathway EE COLI recording via
More informationThe Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss
Med. J. Cairo Univ., Vol. 81, No. 2, September: 21-26, 2013 www.medicaljournalofcairouniversity.net The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss SOHA
More informationAT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.
AT235/AT235h Middle Ear Analyzers Diagnostic & clinical tympanometry with basic audiometry. Fast & reliable middle ear analyzer The AT235 is an automatic middle ear analyzer ideal for diagnostic and screening
More informationDoctor of Audiology Post-Professional Program. Online Education for Practicing Audiologists. AuD. Curriculum Guide
Doctor of Audiology Post-Professional Program Online Education for Practicing Audiologists AuD Curriculum Guide Doctor of Audiology Post-Professional Program Curriculum Guide Course Descriptions Courses
More informationEASY. Comprehensive EP testing
EASY Comprehensive EP testing Auditory Evoked Potential - At its best! E A S Y Comprehensive test battery Easy navigation Flexible display options Straightforward waveform analysis Customized reporting
More informationEMG/EP Measuring System MEB-9400K
EMG/EP Measuring System MEB-9400K More Quickly More Simply Since 1951, Nihon Kohden has been a leader in neurophysiology and has set a number of industry standards. Our original approach and over 50 years
More informationOfficial CPT Description
s CPT 69209 Removal of impacted cerumen using irrigation/lavage, unilateral 69210 Removal impacted cerumen using instrumentation, unilateral 92516 Facial nerve function studies (eg, electroneurography)
More informationElectrophysiologic Assesment II ASLP Spring, 2018
Electrophysiologic Assesment II ASLP 6780-003 Spring, 2018 Instructor: Sharon Miller, Ph.D., CCC-A E-mail: sharon.miller@unt.edu Office: SPHS 214 Office telephone: (940)-369-7385 Office Hours: By appointment
More informationA full product range for your every need. World leading diagnostic solutions
A full product range for your every need World leading diagnostic solutions Future-safe solutions based on knowledge For more than 45 years, Interacoustics has helped the professional world reach new milestones
More informationby Maico Diagnostics
Diagnostic OAE-Tympanometry Combination System by Maico Diagnostics ERO SCAN Pro 3 tests with one probe fit Electronic medical records (EMR), ready Link results to patient's electronic chart with EroScan
More informationNeuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards
Neuro-MEP-Micro 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard EMG according to international standards Instant analysis of high-quality responses Over 50 EMG and EP
More informationGeneral Catalogue. Product Line for Hearing Screening & Diagnostics
General Catalogue Product Line for Hearing Screening & Diagnostics Welcome to the World of MAICO Berlin Dortmund International Sales Team Andreas Kurzbuch Angela Röske Anke Trey Daniel Herrle Melanie Pérez
More informationProvisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009
5 NEWBORN HEARING SCREENING AND ASSESSMENT Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies 10 Suggested parameter values for recording frequency-specific ASSR using Natus
More informationEarly Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners
Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners The Portable OAE Hearing Screener of Choice... Ear canal Middle ear Eardrum The AuDX device
More informationAdditional Information Eclipse
Additional Information Eclipse D-0105222 - E - 2017/09 Valid from software version: EPx5 4.5 ASSR 1.2.7 ABRIS 1.06.2 DPOAE 1.03.2 TEOAE 3.04.3 Table of contents 1 Launching the software... 1 1.1 Starting
More informationRecommended Procedure Cochlear Microphonic Testing
Recommended Procedure Cochlear Microphonic Testing Date: January 2019 Due for review: January 2024 Recommended Procedure Cochlear Microphonic Testing BSA 2019 General foreword This document presents Practice
More informationERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols
ERO SCAN Screener with 4 frequency DPOAE testing Protocols Diagnostic with 4, 6 and 12 frequency DPOAE testing Protocols *TEOAE upgrade OAE Test System ERO SCAN - OAE Test System Physicians Otoacoustic
More informationBio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide
AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide Doc. No.7-26-1374-EN/00 Part No.7-26-13704-EN Natus Medical Denmark ApS. +45 45 75 55 55. otoinfo@natus.com Natus Medical Incorporated.
More informationBio-logic AuDX PRO FLEX Quick start Quick start guide
AuDX PRO FLEX Quick start Quick start guide Doc. No.7-26-1370-EN/00 Part No.7-26-13700-EN Natus Medical Denmark ApS. +45 45 75 55 55. otoinfo@natus.com Natus Medical Incorporated. 1-800-289-2150. otoorder.us@natus.com
More informationEPH - International Journal of Medical and Health Science
CLINICAL NORMS FOR AUDITORY BRAINSTEM RESPONSE TESTING FOR FEMALES AT THE KORLEBU TEACHING HOSPITAL, ACCRA, GHANA Sesi Collins Akotey 1, Geoffrey K. Amedofu 2, Samuel Anim-Sampong 3, Samuel K. Hayford
More informationPURPOSE OF THIS PRESENTATION GUIDELINES DEVELOPMENT CONFERENCE GUIDELINES DEVELOPMENT CONFERENCE: FACULTY GUIDELINES DEVELOPMENT CONFERENCE: OUTCOMES
PURPOSE OF THIS PRESENTATION GUIDELINES DEVELOPMENT CONFERENCE: COMO ITALY 2008 Deborah Hayes, Ph.D. Co-Chair Bill Daniels Center for Children s Hearing The Children s Hospital - Colorado Explain the concept
More informationSRINIVAS (IJHSP), ISSN: 1, 2, PUBLICATION
BERA in Newborns with Hyperbilirubinemia Dr. Edwin Dias Professor and HOD, Department of Paediatrics, Srinivas Institute of Medical Sciences & Research Centre, Mangalore, India E-mail: dredwindias@ @gmail.comm
More informationTEMPLATES FOR COMPREHENSIVE BALANCE EVALUATION REPORTS. David Domoracki PhD Cleveland Louis Stokes VA Medical Center
TEMPLATES FOR COMPREHENSIVE BALANCE EVALUATION REPORTS David Domoracki PhD Cleveland Louis Stokes VA Medical Center The following templates are in outline form. I designed them so that the IRM local network
More informationThresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan
ORIGINAL ARTICLE Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan Chung-Yi Lee, 1,2 Tai-Hsin Hsieh, 2 Shin-Liang Pan, 3 Chuan-Jen Hsu 2
More informationGeneral Catalogue. Hearing Screening & Diagnostics
General Catalogue Hearing Screening & Diagnostics Welcome to the World of MAICO Berlin Dortmund International Sales Team Andreas Kurzbuch Angela Röske Melanie Pérez Salas Nadine Kerren 2 Anke Trey Daniel
More informationGSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard
GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full
More informationCoding with Confidence:
Coding with Confidence: CPT, HCPCS, Modifiers & ICD-10 Alyssa Needleman, PhD Nova Southeastern University August 4, 2017 Coding Considerations: Procedure (CPT, HCPCs) and Diagnosis (ICD-10) Code for test/procedure(s)
More informationAuditory Steady-State Response (ASSR): A Beginner's Guide by Douglas L. Beck, AuD, David P. Speidel, MS, Michelle Petrak, PhD
Auditory Steady-State Response (ASSR): A Beginner's Guide by Douglas L. Beck, AuD, David P. Speidel, MS, Michelle Petrak, PhD This article was submitted to HR by Douglas L. Beck, AuD, director of professional
More informationAdditional Information Eclipse
Additional Information Eclipse D-0120572-A - 2018/06 Valid from software version: EPx5 4.5 ASSR 1.2.7 ABRIS 1.06.2 DPOAE IA OAE Software 1.0 TEOAE IA OAE Software 1.0 Table of contents 1 Launching the
More information2) What is the most robust distortion product evoked with DPOAEs? A. F1 B. F2 C. 2F1-F2 D. 2F2 F1
Instructions: Look at the following questions below in their respective categories, and check your answers against the Answer Key on the last page. Contact the SAA Programs Subcommittee Chair with any
More informationName: Bahram Jalaei. Department of Audiology School of Rehabilitation Sciences Iran University of Medical Sciences Tehran, Iran
CURRICULUM VITAE Name: Bahram Jalaei Department of Audiology School of Rehabilitation Sciences Iran University of Medical Sciences Tehran, Iran E-mail: jalaei.b@iums.ac.ir E-mail: mojtajal@gmail.com EDUCATION
More informationGeneral Catalogue. Hearing Screening & Diagnostics
General Catalogue Hearing Screening & Diagnostics Welcome to the World of MAICO Berl erllin i Dortmund International Sales Team Andreas Kurzbuch Angela Röske Anke Trey Daniel Herrle Melanie Pérez Salas
More informationVEMP: Vestibular Evoked Myogenic Potential
VEMP is a neurophysiological assessment technique used to determine the function of the otolithic organs (utricle and saccule) of the inner ear. It complements the information provided by other forms of
More informationCurrent Perspectives in Balance Assessment. Topics for Today. How are we doing? 3/5/2010. Scott K. Griffiths, Ph.D. March 26, 2010
Current Perspectives in Balance Assessment Scott K. Griffiths, Ph.D. March 26, 2010 Topics for Today Evaluating the Dizzy Patient looking back, looking ahead The (Not So) New Kids on the Block: VEMPs,
More informationAudiology (Clinical Applications)
(Clinical Applications) Sasan Dabiri, M.D. Assistant Professor Department of Otorhinolaryngology Head & Neck Surgery Amir A lam hospital Tehran University of Medical Sciences Last Updated in February 2015
More informationfirst described by Starr 1996 as a subgroup of patients with
Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, Plastische und Ästhetische Operationen Direktor: Prof. Dr. R. Hagen W. E. Shehata-Dieler, J. Müller, C. Völter, R. Hagen first described by
More informationUsing Electrocochleography to Assess the Afferent Pathway in the Cochlea. Senior Thesis
Cochlear afferent pathway 1 RUNNING HEAD: Cochlear afferent pathway Using Electrocochleography to Assess the Afferent Pathway in the Cochlea Senior Thesis Presented in Partial Fulfillment of the Requirements
More informationGeneral Catalogue. Product Line for Hearing Screening & Diagnostics
General Catalogue Product Line for Hearing Screening & Diagnostics Welcome to the World of MAICO Berlin Dortmund International Sales Team Andreas Kurzbuch Angela Röske Anke Trey Daniel Herrle Melanie Pérez
More informationAC40. The true clinical. hybrid
AC40 The true clinical hybrid The true clinical hybrid audiometer Stand alone & PCbased audiometry in one box A true hybrid audiometer The AC40 full two channel audiometer includes all the advanced features
More informationNEURODIAGNOSTIC TECHNOLOGIST SPECIALTY
QTP 4N0X1B-10 24 October 2014 NEURODIAGNOSTIC TECHNOLOGIST SPECIALTY TOTAL FORCE, TOTAL CARE EVERYTIME, ANYWHERE Medical Education & Training Campus Neurodiagnostic Technologist Program 3480 Garden Avenue,
More informationBio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide
AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide Doc. No.7-26-1375-EN/00 Part No.7-26-13705-EN Natus Medical Denmark ApS. +45 45 75 55 55. otoinfo@natus.com Natus Medical Incorporated. 1-800-289-2150.
More informationThe registration testing for audiometric device in CFDA
The registration testing for audiometric device in CFDA Beijing Center for Medical Devicee Quality Supervision and Testing of China Food and Drug Administration Beijing Institute of Medical Device Testing
More informationOAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.
OAE Test System by Maico Diagnostics ERO SCAN EroScan Pictured OAE Hearing Screener DPOAE/TEOAE Test Systems www.maico-diagnostics.com Ero Scan - OAE Test System Visual Evaluation Middle Ear Evaluation
More informationSimultaneous multiple stimulation of the auditory steadystate response (ASSR)
Simultaneous multiple stimulation of the auditory steadystate response (ASSR) Cl a u s El b e r l i n g 1, Ma r i o Ce b u l l a 2 a n d Ek k e h a r d St ü r z e b e c h e r 3 1 Oticon A/S, Eriksholm,
More informationDOWNLOAD OR READ : VESTIBULAR EVOKED MYOGENIC POTENTIAL ITS BASICS AND CLINICAL APPLICATIONS PDF EBOOK EPUB MOBI
DOWNLOAD OR READ : VESTIBULAR EVOKED MYOGENIC POTENTIAL ITS BASICS AND CLINICAL APPLICATIONS PDF EBOOK EPUB MOBI Page 1 Page 2 vestibular evoked myogenic potential its basics and clinical applications
More informationEDUCATION University of Texas at Dallas-Dallas, Texas Doctor of Philosophy-Audiology ( )
Teralandur K. Parthasarathy, Ph.D., CCC-A., FAAA 344 Westminster Drive. Glen Carbon, Illinois 62034. (618) 288-2894 tpartha@siue.edu; 618-650-3676 (Office); Founders Hall/1334 EDUCATION University of Texas
More informationOperation Manual. The Eclipse Platform EP15, EP25, TEOAE25, DPOAE20, ABRIS, ASSR. Introduction. The Eclipse Hardware and Software Installation
The Eclipse Platform Operation Manual EP15, EP25, TEOAE25, DPOAE20, ABRIS, ASSR Introduction The Eclipse Hardware and Software Installation Using the EP15 and EP25 Using the TEOAE25 Using the DPOAE20 Using
More informationVESTIBULAR FUNCTION TESTING
VESTIBULAR FUNCTION TESTING Non-Discrimination Statement and Multi-Language Interpreter Services information are located at the end of this document. Coverage for services, procedures, medical devices
More information