TRANSFER OF THE FUNCTIONALISED TEMPORARY transfer of the functionalized temporary from the oral cavity to the verticulator

Size: px
Start display at page:

Download "TRANSFER OF THE FUNCTIONALISED TEMPORARY transfer of the functionalized temporary from the oral cavity to the verticulator"

Transcription

1 TRANSFER OF THE FUNCTIONALISED TEMPORARY transfer of the functionalized temporary from the oral cavity to the verticulator What you need for this working: EQUIPMENT VERTYS SPLIT CAST & GUM VERTYS DYNAMO BLOCK VERTYS ARTIC LINK 1F + 1M FURBO PLEXI APOLIX AR.GO FURBO ALU SMALL APOLIX CU-BA (Curing Basket) VERTYS SIRIN- GHE + HANDLE CONSUMABLES VERTYS TEM- PLUS LIQUID COLD VERTYS ORANGE PLUS VERTYS PRECI- SION VERTYS TEM- PLUS MONOMASSA MM VERTYS ORANGE SPECIAL LUBE VERTYS EASY PUTTY 5 Kg VERTYS RETARD 1/5 E. info@

2 INTRO Transfer of the temporary from the oral cavity to the FURBO PLEXI verticulator Duplication of temporary therapeutic elements with FURBO ALU BIG / SMALL muffle and FURBO PLEXI verticulator 1.PASSAGE IN THE DENTAL CLINIC Dental Clinic Set FURBO ALU SMALL muffle VERTYS ORANGE PLUS Silicone VERTYS EASY PUTTY Silicone VERTYS PRECISION Silicone VERTYS ORANGE SPECIAL LUBE Insulator Before the final impression, and before cementation of the temporary circular, take a chewing report, as usual, with a very stable material, such as Luxabite, front and back Proceed with the provisional scementation If the temporary was divided, join it, inserted into the oral cavity, with a fluid composite Take the FURBO ALU SMALL muffle and detach the red split plate Turn the crowns over and fill them with the silicone VERTYS PRECISION PICTURE 1 (leave the cement inside the crowns) Knead 60 g of VERTYS ORANGE PLUS, fit it inside the muffle shaft and sink the temporary, filled with VERTYS PRE-CISION PICTURE 2 if possible put everything in a heat press or pressure cooker: - without water - at temperature 0 C / zero degrees centigrade (with thermostat deactivated) - at the pressure of at least 2 atmospheres, maximum 6 atmospheres for 5/7 min. In this way we will obtain a silicone model Cut the model with a scalpel in order to leave 1mm of edge as shown in PICTURE 3 Insulate the silicone model with VERTYS ORANGE SPECIAL LUBE PICTURE 4 Kead the VERTYS ORANGE PLUS silicone, (15 g A + 15 g B) and completely cover the molded PICTURE 5Impastare il silicone VERTYS ORANGE PLUS, (15 g A + 15 g B) e coprire completamente il modellato PICTURE 5 Insert the model covered with VERTYS ORANGE PLUS, in a heat press or pressure cooker - without water - at temperature 0 C / zero degrees centigrade (with thermostat deactivated) - at the pressure of at least 2 atmospheres, maximum 6 atmospheres for 5/7 min. PICURE 6 Remove all possible thicknesses on the rods, in order to avoid waste of VERTYS EASY PUTTY N.B. It is very important to put the same thicknesses on the rods above the cover in order to close the muffle with the locking nuts PICTURE 7 Now cover the VERTYS ORANGE PLUS now with the VERTYS EASY PUTTY Fit approximately half of the dough to the inside of the FURBO ALU SMALL muffle cover and use the remaining VERTYS EASY PUTTY for silicone model boxing Insert the muffle cover in the appropriate guide rods and compress until the cover is in contact with the spacers on the 3 guide rods Immediately lock the muffle cover with the appropriate locking nuts Tighten with the VERTYS DYNAMO BLOCK torque nut First compress the escaped silicone from the upper muffle louver and, immediately afterwards, the leaked silicone at the model base In this way, the silicone is adapted to the model itself and a perfect seal This phase must be carried out with the utmost care to prevent the resin from escaping when it is subsequently injected For a perfect closure of the Alu Small muffle, the spacers must not rotate on the guide rods Wait for the VERTYS EASY PUTTY to harden for about 7 minutes Once hardened, unscrew the nuts and remove the muffle cover from the 3 guide rods Take the silicone model out of the mask-mold into the muffle cover The mold and the counter mold in silicone have thus been obtained PICTURE 8 In the meantime the technician has prepared the abutments. Using temporary half with the first occlusal relationship on the antagonist teeth, record the occlusion with suitable Luxabite material on the abutments After these steps, the technician will have in the laboratory: Definitive impression - Facial Arch Occlusal registration on the temporaries Mold and counter mold of the temporary silicone, for injection and duplication Written report on any changes to be made on the shape of the teeth Patient s photo To lengthen the processing time of our Putty silicones, we recommend the use of the liquid # VERTYS RETARD. A drop corresponds to one more minute of processing. 2/5 E. info@

3 ATTENTION: assumes no responsibility for the final result, if you do not use the consumables of the VERTYSYSTEM line. The times, quantities and temperatures of this protocol refer only to these materials. The VERTYS SILICONI LINE has been specifically designed for the use of Systematics, allowing to replicate the artefact at any time We therefore recommend archiving and storing the masks The technician may have his own FURBO ALU SMALL muffle in the studio as it is necessary to have only the mold and the counter silicone mold.i All the silicone recordings made in the various VERTYSYSTEM equipment are interchangeable. A. PHOTOS OF THE PASSAGES TO BE PERFORMED IN THE DENTAL CLINIC PICTURE 1 PICTURE 2 PICTURE 3 PICTURE 5 PICTURE 6 PICTURE 7 PICTURE 8 PICTURE 9 3/5 E. info@

4 2. PASSAGE IN THE ODONTOTECHNIC LABORATORY Impressions arrive in the laboratory already disinfected and accompanied by prescription of work, data from the doctor s office and references of the patient or, alternatively, an identification code The operator responsible for acceptance checks the completeness of the data, records the work and completes the technical sheet The operator verifies the material with which the impressions were taken and establishes the type of material to be used to develop the models. Class IV gypsum or polyurethane resin is recommended Mix the under vacuumed gypsum, in the proportions and times indicated by the manufacturer An electric vibrator can be used to cast the impression The plaster base of the model must be made on the special Split Cast of the VERTYSYSTEM Systematics. Alternatively, you can use the VERTYS ARTIC LINK M base (see specific instructions) The developed model is disengaged, trimmed and squared Position the models in the articulator using the VERTYS ARTIC LINK F plates Place the centric rod on the 0 A. PREPARATION OF THE FURBO ALU SMALL MUFFLE Take the FURBO ALU SMALL muffle with the mold and the counter silicone mold inserted With the supplied reamers drill two holes in the silicone at the two ends of the molding, starting from the inside of the mask-to-mold until it comes out of the muffle cover In this way the inlet and outlet channels for the injection of the acrylic resin are made Entrance hole with large reamer # Output hole with small reamer # Using the correct reamer ensures that the hole diameter exactly matches the diameter of the syringe tip that will be used for resin injection The outlet hole must always be made with the small reamer With a scalpel, perform a flaring on the silicone in correspondence with both holes Two grooves will be created which will serve to contain the resin reserve when it is injected Immediately lock the muffle cover with the appropriate locking nuts Tighten with the VERTYS DYNAMO BLOCK torque nut B.RESIN PREPARATION FOR VERTYS TEMPLUS PROVISIONS Weigh the necessary amount of powder and liquid of the acrylic resin VERTYS TEMPLUS in the proportion 1: 2 (example: 1 g of liquid - 2 g of powder) Keep in mind that for an element of medium size, 0.5 g of powder are sufficient. Pour the liquid into a special container Then pour the powder and mix with the liquid for at least 10 seconds Cover the mixture with a lid and allow the resin to cure for 10 seconds. approximately, until it assumes a filamentous consistency Mix again for 5 seconds. and pour the resin into a 20 cc disposable syringe, making sure to close the exit hole with a finger Insert the plunger and invert the syringe. Push the plunger until air bubbles escape Continue to exert pressure on the plunger until a small leakage of the VERTYS TEMPLUS resin from the tip of the syringe When the resin takes on a filamentous consistency it is ready for injection NB: The maturation and injection times can vary, even considerably, depending on the environmental conditions C. INJECTION PROCEDURE OF ACRYLIC RESIN Hold the muffle at an angle of 45 with one hand so that the entry hole is at the bottom and the outlet hole at the top This will avoid the inclusion of bubbles during the injection phase. Now insert the tip of the syringe into the lower entry hole and slowly push the plunger until the resin comes out of the upper hole Always keep the syringe plunger under pressure, straighten the flask, place it on the work bench and continue the injection and thrust phase Using a spatula, remove the resin gradually, as it emerges from the smallest hole until the resin takes on an opaque and consistent appearance. It is important not to remove all the resin, but leave the groove, previously created, full. Slowly withdraw the syringe while continuing to apply pressure As soon as the syringe tip has escaped from the hole, immediately create the second reservoir. The injection is completed and the two reserve buttons are now visible at the two inlet and outlet wells D.ACRYLIC RESIN POLYMERIZATION Insert the crafty ALU SMALL muffle in the heat press or pressure cooker paying close attention to: 1. The water inside the heat press must be at room temperature 2. The water level must not exceed the muffle cover (it is very important that the two inlet and outlet holes of the resin are not covered with water) 3. The pressure must not exceed 2 atmospheres 4/5 E. info@

5 For temperature and cure times follow the instructions for use of the VERTYS TEMPLUS resin Once cured, remove the muffle from the heat press or pressure cooker Remove the two resin buttons at the grooves, open them with the aid of a plaster knife or cutting them with a dia-mantled disc Open the muffle and remove the product from the silicone mold-template Remove the two input and output plugs with a cutter At this point cut the collars and shell out the duplicate of the temporary. This way you do not risk damaging the master model Place the temporary duplicate, discharged into the crowns, on the antagonist model mounted in the articulator, using the first recordings taken between the teeth. By gently closing the articulator, check that there is no interference between the crowns and the abutments Now fill the crowns with VERTYS PRECISION and close the articulator In this way we have reported the duplicate in the articulator, without damaging the abutments Make any changes to the resin teeth with any wax Completed and finished the occlusal and incisal wax modeling, bring the model on the verticulator, and always with the VERTYS ORANGE PLUS silicone, record the third incisal From now on we will work almost exclusively in the FURBO PLEXI Verticulator With this silicone registration in the Verticulator lid, we will perform the following operations: Guided construction of the metal girder Construction of the third incisal on the metal, with resin from provisionals, for the patient test Registration with VERTYS PRECISION silicone of any modifications during the metal test Metal grinding Molding of ceramics or composite Thanks to this technique, our initial project will be respected by all operators from the beginning to the end of the work. Many mistakes will be avoided and the printed porcelain article will be faithful to the project, free of bubbles and cracks and with a superior chromatic quality. E. PHOTOS OF THE STEPS TO BE FOLLOWED IN THE LABORATORY PICTURE 11 PICTURE 12 PICTURE 13 PICTURE 14 PICTURE 15 PICTURE 16 PICTURE 17 PICTURE 18 PICTURE 19 PICTURE 20 5/5 E. info@

PARTIAL MOBILE DENTURE with Vertys Prothesis Excel / Plus termo-polimerizing resin

PARTIAL MOBILE DENTURE with Vertys Prothesis Excel / Plus termo-polimerizing resin PARTIAL MOBILE DENTURE with Vertys Prothesis Excel / Plus termo-polimerizing resin What you need for this working: EQUIPMENT 10-0010 VERTYS SPLIT CAST & GUM 10-100 APOLIX 10-3000 AR.GO 10-2501 FURBO ALU

More information

SKELETAL PROTHESIS with Vertys Prothesis Excel / Plus heat-curing resin

SKELETAL PROTHESIS with Vertys Prothesis Excel / Plus heat-curing resin SKELETAL PROTHESIS with Vertys Prothesis Excel / Plus heat-curing resin What you need for this working: EQUIPMENT 10-0010 VERTYS SPLIT CAST & GUM 10-100 APOLIX 10-3000 AR.GO 10-2501 FURBO ALU BIG 10-130

More information

Universal Plunger Loc Attachment

Universal Plunger Loc Attachment Universal Plunger Loc Attachment www.preat.com 800-232-7732 Universal Plunger Loc Complete Universal 7.5mm length TI plunger attachment. Compatible with Lew Passive and Swiss Loc NG. 1.5mm plunger, 7.5mm

More information

SS Implant System 2013 PROSTHETIC PROCEDURE

SS Implant System 2013 PROSTHETIC PROCEDURE SS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement-retained bridges with the Solid abutment system (non-modified abutment) 16 Cement-retained bridges

More information

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of crown fitting quality Contemporary methods of restoration of tooth tissues pathology, using

More information

OT EQUATOR CASTABLE Single Attachment for Overdentures

OT EQUATOR CASTABLE Single Attachment for Overdentures OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)

More information

STEP-BY-STEP-ANLEITUNG

STEP-BY-STEP-ANLEITUNG STEP-BY-STEP-ANLEITUNG VON TECHNIKERN FÜR TECHNIKER LABORATORY PROCEDURES, STEP BY STEP BY TECHNICIANS FOR TECHNICIANS Eclipse junior Laboratory Procedures, Step by Step* Splints Drilling Stents Temporaries

More information

Frequent use for the preparation of prosthetic products

Frequent use for the preparation of prosthetic products laboratory use Frequent use for the preparation of prosthetic products Silicones gain more and more use for the preparation of prosthetic products. ERGAMIX addition silicone (polyvinylsiloxane) and ERGASIL

More information

FR Attachment Instructions Removable Partial Dentures

FR Attachment Instructions Removable Partial Dentures www.preat.com 800-232-7732 FR Attachment Instructions Removable Partial Dentures 1 2 Adjust the master cast on mounting platform of the surveyor to the chosen angle of insertion. Check to be sure the tooth

More information

Hex-Lock Abutment System. Restorative Manual

Hex-Lock Abutment System. Restorative Manual System Restorative Manual 32 Restorative options with s s are manufactured from titanium alloy and used as the support foundation for single- or multiple-unit cement-retained, partially edentulous fixed

More information

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions INTRODUCTION synocta Meso abutment for cement-retained restorations 1 The synocta Meso abutments, available

More information

Individual Tools for Controlling and Positioning Porcelain Veneers: Easychecker The Aesthetic Key Ralf Barsties, CDT and Dr.

Individual Tools for Controlling and Positioning Porcelain Veneers: Easychecker The Aesthetic Key Ralf Barsties, CDT and Dr. Individual Tools for Controlling and Positioning Porcelain Veneers: Easychecker The Aesthetic Key Ralf Barsties, CDT and Dr. Franka Meuter 58 Spectrum dialogue Vol. 11 No. 4 April 2012 Ceramic veneers

More information

ident CT Guide Protocol

ident CT Guide Protocol ident CT Guide Protocol The ident computer planning and iguide production starts with the CT Guide. This is a simple device which can be made by a dental technician, but it is essential that it is made

More information

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir (Protocol C All-CAD with Multi-Unit Abutments) Step-by-Step Restorative Protocol C The BruxZir Full-Arch Implant Prosthesis offers a fixed, all-zirconia implant solution for edentulous patients desiring

More information

VIP Partner Laboratory (PL) Process Flow

VIP Partner Laboratory (PL) Process Flow VIP Partner Laboratory (PL) Process Flow 1. VIP Software 2. CT Scan Appliance 3. CT Scan Clinician purchases VIP for PL fabricates CT Scan Appliance Patient submitted for scans treatment planning purposes

More information

MAURO FRADEANI, MD, DDS

MAURO FRADEANI, MD, DDS ESTHETIC REHABILITATION IN FIXED PROSTHODONTICS PROSTHETIC MAURO FRADEANI, MD, DDS Private Practice Pesaro and Milan, Italy TREATMENT A SYSTEMATIC APPROACH TO ESTHETIC, BIOLOGIC, AND FUNCTIONAL INTEGRATION

More information

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique A novel cementless option Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique Zimmer Trabecular Metal Primary Patella 1 Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

More information

Element-Z Screw-Retained Hybrid

Element-Z Screw-Retained Hybrid Element-Z Screw-Retained Hybrid Implant-Level Restoration Step-by-Step Restorative Protocol The Element-Z Screw-Retained Hybrid offers a fixed, all-ceramic implant solution for edentulous patients desiring

More information

PRIMARY POROUS PATELLA WITH TRABECULAR METAL. Surgical Technique

PRIMARY POROUS PATELLA WITH TRABECULAR METAL. Surgical Technique PRIMARY POROUS PATELLA WITH TRABECULAR METAL Surgical Technique 1 SURGICAL TECHNIQUE FOR NEXGEN PRIMARY POROUS PATELLA * WITH TRABECULAR METAL CONTENTS PREPARE THE PATELLA............... 2 Patella Reamer

More information

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments Indications Instructions The Locator Root Attachment is designed for use with overdentures or partial dentures, retained in whole or in part by endodontically treated roots in the mandibular or maxilla.

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure TSH BNT Regeneration Implant Systems CAD-CAM Digital Solutions Services Important: before using Phibo The innovative and patented design of the Phibo implant systems incorporates

More information

Diagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener

Diagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener Diagnosis 220 Temporary Filling Carrier Periodontics Periodontal Curette / Sharpener Conservative Treatment Composite Syringe / Rubber Dam Punch / Clamp Forceps / Rubber Dam Kit / Reamer Stand / Endodontic

More information

Denture Duplicator Flask

Denture Duplicator Flask Denture Duplicator Flask Package Contents REF 0398 One Flask REF 0395 One Flask, Jet Tooth Shade Powder: 2x45 g Net Wt., Jet Denture Repair Powder: 2x100 g Net Wt., Jet Liquid: 236 ml Net Vol., Silicone

More information

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants

More information

Trabecular Metal Primary Patella

Trabecular Metal Primary Patella Trabecular Metal Primary Patella NexGen Complete Knee Solution Surgical Technique Table of Contents Introduction... 2 Prepare the Patella... 2 Patella Reamer Technique... 3 Insetting Technique... 5 Universal

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure Aurea Regeneration Implant Systems CAD-CAM Digital Solutions Services AUREA IMPLANT SYSTEM PROSTHODONTIC PROCEDURE IMPORTANT BEFORE USING AUREA IMPLANT SYSTEM The innovative and

More information

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health Warren Grant Magnuson Clinical Center National Institutes of Health What is a subcutaneous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous

More information

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD) CHAPTER 17 Tooth preparation for posterior fi xed partial denture (FPD) 1 Defi nition and feature of FPD 2 Actual sequence of tooth preparation for posterior FPD Verify abutment teeth Occlusal guide groove

More information

Chapter 5: Checking and Maintaining Ultrasound Equipment

Chapter 5: Checking and Maintaining Ultrasound Equipment Chapter 5: Checking and Maintaining Ultrasound Equipment Care and Cleaning (BB1564-AJ) Chapter 5: Checking and Maintaining Ultrasound Equipment 45 Ultrasound equipment requires regular checks and maintenance.

More information

INTRODUCTION. Why Choose Cortex Prosthetics?

INTRODUCTION. Why Choose Cortex Prosthetics? Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5

More information

US Implant System 2013 PROSTHETIC PROCEDURE

US Implant System 2013 PROSTHETIC PROCEDURE US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment

More information

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction Reference to primary publication in ZWP 4/2014 Dr. Marcus Holzmeier, Wuerzburg Xantalgin Crono - Highly accurate alginate impressions. Introduction Even today when digital impression techniques are gaining

More information

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME Zimmer NexGen MIS Tibial Component Cemented Surgical Technique IMAGE TO COME Zimmer NexGen MIS Tibial Component Cemented Surgical Technique 1 Zimmer NexGen MIS Tibial Component Cemented Surgical Technique

More information

Preci Clix Instructions for Ball Retained Overdenture Attachments

Preci Clix Instructions for Ball Retained Overdenture Attachments www.preat.com 800-232-7732 Preci Clix Instructions for Ball Retained Overdenture Attachments Dentist Direct Placement Technique In one appointment, an existing removable partial denture may be converted

More information

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary

More information

TJF-160F/VF Cleaning and Disinfection Checklist

TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-160F/VF has been performed

More information

UDELL DENTAL LABORATORY Instructions for Use

UDELL DENTAL LABORATORY Instructions for Use DALLA BONA Summary Cylindrical Dalla Bona Rigid precision attachment. Radicular telescopic stud. Adjustable frictional retention. Gold alloy male (Elitor) and female (OSV). Fixation: Male - soldered to

More information

Face-Bow Instructions

Face-Bow Instructions M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 The following procedure is followed when Panadent Bite-Tab compound discs are used

More information

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm STERN ERA IMPLANT ABUTMENT Summary Resilient precision overdenture attachment. Universal hinge with vertical movement. Titanium abutment, nylon male. Manufactured for most popular screw and cylinder implants.

More information

SimpleLine II Surgical / Prosthesis Manual

SimpleLine II Surgical / Prosthesis Manual SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll

More information

MIS Cemented Tibial Component

MIS Cemented Tibial Component MIS Cemented Tibial Component NexGen Complete Knee Solution Surgical Technique Table of Contents Surgical Exposure... 2 Finish the Tibia... 2 Position Based on Anatomic Landmarks... 3 Lateral Posterior

More information

IMPRESSION PROCEDURES TRAINING MANUAL

IMPRESSION PROCEDURES TRAINING MANUAL IMPRESSION PROCEDURES TRAINING MANUAL 01 01 A.B. DENTAL A.B. Dental is proud to present this impression taking procedure protocol. This manual explains, step by step, the procedure while using A.B. Dental

More information

Straight Octagon Abutment for Tissue Level Implant

Straight Octagon Abutment for Tissue Level Implant Cover screw in place The presentation that follows lists only one combination of parts. Obviously the clinical situation may call for substitution of another part on this slide Prosthetic instruments needed

More information

Rhino Clear Sprint Atomizer

Rhino Clear Sprint Atomizer Visit us online to view our wide range of sinus therapy medications for use with the Rhino Clear Sprint atomizer. www.woodlandhillspharmacy.com 20631 Ventura Blvd, Ste 305 Woodland Hills, CA 91364 Phone:

More information

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS Presurgical planning Health history-systemic conditions Case presentation Financial agreement Radiographs- PA s, FMX, Panoramic,

More information

LABORATORY PROCEDURES, STEP BY STEP

LABORATORY PROCEDURES, STEP BY STEP LABORATORY PROCEDURES, STEP BY STEP BY TECHNICIANS FOR TECHNICIANS Eclipse Laboratory Procedures, Step by Step* Dentures with cast-metal frameworks Combination dentures Complete dentures Splints Drilling

More information

How something small, can make such a big difference!! Your best choice in overdenture

How something small, can make such a big difference!! Your best choice in overdenture How something small, can make such a big difference!! Your best choice in overdenture Why? Kerator has the worldʼs most powerful competitiveness in overdenture attachment system. KERATOR was chosen over

More information

The fitting process of SomnoGuard

The fitting process of SomnoGuard The fitting process of SomnoGuard Hints to complement the actual user instructions AP Tomed Dr. Toussaint GmbH, 31.07.2010 Needed accessories Spray disinfectant for all working tools Boling water bath

More information

Even faster thanks to ExpertEase Immediate restoration directly following implant placement. new

Even faster thanks to ExpertEase Immediate restoration directly following implant placement. new Even faster thanks to ExpertEase Immediate restoration directly following implant placement new The Initial Situation: Patients want beautiful teeth quickly preferably directly after the implantation Patients

More information

Relining and Rebasing of complete denture

Relining and Rebasing of complete denture Relining and Rebasing of complete denture It is the procedures used to resurface the tissue-side of a denture with new material layer, thus producing an accurate adaptation to the denture foundation area.

More information

Impression Manual.

Impression Manual. Impression Manual www.paladigitaldentures.com Contents Page 1 Requirements for Impressions Complete Denture Single Arch Maxillary Denture Single Arch Mandibular Denture Maxillary Impression Maxillary

More information

The fitting process of SomnoGuard AP. Hints to complement the user instructions

The fitting process of SomnoGuard AP. Hints to complement the user instructions The fitting process of SomnoGuard AP Hints to complement the user instructions Essential equipment and instruments Spray disinfectant for all instruments Boling water bath Water boiler Disposable gloves

More information

There is one thing different. Everything.

There is one thing different. Everything. There is one thing different. Everything. THE MODEL MAKER THE SET-UP MODEL MAKER THE OCCLUSAL PLANE REFERENCE THE SURGICAL MODEL ACCURACY DEVICE Precise - Easy - Clean - Economical - Multi Purpose - Essential

More information

1. Visually survey the cast for discrepancies and surface defects. 2. Remove surface defects and fill unnatural indentations.

1. Visually survey the cast for discrepancies and surface defects. 2. Remove surface defects and fill unnatural indentations. PROCEDURE CHECKLIST: SURVEY AND DESIGN 1. Visually survey the cast for discrepancies and surface defects. 2. Remove surface defects and fill unnatural indentations. 3. Visually survey cast to determine

More information

Occlusal Splint Fabrication Technique

Occlusal Splint Fabrication Technique Occlusal Splint Fabrication Technique Safety glasses should be worn for all lab procedures as well as gloves when handling acrylics. Items featured in this technique are found on the last page. 1 Mount

More information

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag. PROSTHESIS MANUAL INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL

More information

áåi~ä=pa=ñçê=^äìíãéåíë=spksu

áåi~ä=pa=ñçê=^äìíãéåíë=spksu kéï=~ë=çñw== MVKOMMV áåi~ä=pa=ñçê=^äìíãéåíë=spksu lééê~íçêûë=j~åì~ä pìééäéãéåí=íç=ëçñíï~êé=îéêëáçå=áåi~ä=pa=spksu båöäáëü Table of contents Sirona Dental Systems GmbH Table of contents 1 How to use the

More information

Predictable Real World Aesthetics. The Key to Success with Natural Restorations

Predictable Real World Aesthetics. The Key to Success with Natural Restorations The Insiders Guide to Quality Dentistry Predictable Real World Aesthetics The Key to Success with Natural Restorations ISUS CAD/CAM Implant Supra-Structures: Accuracy, durability and precision Conscious

More information

For the oral rehabilitation

For the oral rehabilitation For the oral rehabilitation Contents For superstructures Chapter 1 Overview of prosthetic modes 1. Prosthetic modes of the PLATON system 2. Factors involved in prosthetic design Chapter 2 Cement-retained

More information

Quintessence copyright. You are not allows to show or use this file for any other purpose than personal use.

Quintessence copyright. You are not allows to show or use this file for any other purpose than personal use. Quintessence copyright. You are not allows to show or use this file for any other purpose than personal use. P. Tardieu November 2005 2. Radiological Templates A radiological template is a radiopaque duplicate

More information

SICAT Surgical Guides. Fabrication of Radiographic Templates Conebeam/CT scanning parameters 3-D Implant planning Ordering Surgical Guides

SICAT Surgical Guides. Fabrication of Radiographic Templates Conebeam/CT scanning parameters 3-D Implant planning Ordering Surgical Guides SICAT Surgical Guides Fabrication of Radiographic Templates Conebeam/CT scanning parameters 3-D Implant planning Ordering Surgical Guides 2 Table of contents 1. SICAT Surgical Guides... 4 1.1 Important

More information

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants BIO Multi-Units are available for all our Bone Level Implants Multi-Units abutments are ideal for following restorative plans Blue Sky Bio offers a variety of components that can be used with BIO Multi-units.

More information

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System Bisco PRO-V IDS Kit Provisional Restorative System Instructions for Use U.S. Patent: 7,748,980; 8,106,110 IN-199R3 Rev. 5/16 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 847-534-6000

More information

Preci Clix Instructions for Ball Retained Overdenture Attachments

Preci Clix Instructions for Ball Retained Overdenture Attachments www.preat.com 800-232-7732 Preci Clix Instructions for Ball Retained Overdenture Attachments Dentist Direct Placement Technique #1293 / 1297 In one appointment, an existing removable partial denture may

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8823 Convex Array Transducer English BB1740-C June 2012 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkmed.com Email:

More information

Linear Array Transducer

Linear Array Transducer User Guide Type 8809 Linear Array Transducer English BB 0911-H August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial How do I prepare and give an injection with Enbrel multiple-dose vial? A multiple-dose vial contains

More information

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS: ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Read the Instructions for Use before you start using ALPROLIX and each time you get a refill. There may be new information.

More information

Greater Component Accuracy...

Greater Component Accuracy... Greater Component Accuracy... StageOne cement spacer molds are designed to provide the surgeon with choices never before offered in two-stage revision knee surgery for an infected total joint. StageOne

More information

Prosthetic V. Removable dentures I.

Prosthetic V. Removable dentures I. Prosthetic V. Removable dentures I. Removable dentures Partial Complete (full) lenka.roubalikova@tiscali.cz 2 Prosthetic dentistry replacement of Damaged teeth reconstruction of the crown (inlays, crowns)

More information

Listing of Standards By Task

Listing of Standards By Task Listing of Standards By Task PARTIAL DENTURES 1. Disinfect the impression and/or model 2. Evaluate the prescription for completeness 3. Document changes to the prescription 4. Evaluate the impression or

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure TSA TSA Advance Regeneration Implant Systems CAD-CAM Digital Solutions Services IMPORTANT: BEFORE USING Phibo The innovative and patented design of the Phibo implant systems incorporates

More information

From planning to surgery: a totally digital working flow for Leone implants placement

From planning to surgery: a totally digital working flow for Leone implants placement Dr. Giancarlo Romagnuolo Roma, Italy From planning to surgery: a totally digital working flow for Leone implants placement Keywords guided surgery, 3D implant planning, single missing tooth, delayed immediate

More information

Straumann synocta Prosthetic System Basic Information. Technical Information

Straumann synocta Prosthetic System Basic Information. Technical Information Straumann synocta Prosthetic System Basic Information Technical Information About this guide The Basic Information on the Straumann synocta Prosthetic System provide dental practitioners and related specialists

More information

Removable Prosthodontics. Complete Denture Procedures for a Team Approach in the Home

Removable Prosthodontics. Complete Denture Procedures for a Team Approach in the Home Department of General Dentistry Division of Removable Prosthodontics Complete Denture Procedures for a Team Approach in the Home For Competency #9 1 Rev. April 2010 Ronni A. Schnell, D.M.D., M.A.G.D. and

More information

Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success

Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success Treatment Planning/Diagnosis 1. Setup meeting with Treatment Team to discuss case communication is key 2. Qualifying the

More information

NC DOUBLE OPPOSING HEAD DRILL

NC DOUBLE OPPOSING HEAD DRILL NC DOUBLE OPPOSING HEAD DRILL 720ATD 720ATD 1800 x 1100 mm 2600 x 1600 mm 3000 x 2200 mm 3000 x 2600 mm 1. GENERAL PERFORMANCE 720ATD/20 Maximum glass dimension 3000 x 2600 Total weight Maximum Glass weight

More information

Complete denture impressions

Complete denture impressions Lec.5 Complete denture impressions د. غسان الطائي Dental Impression: a negative imprint of an oral structure used to produce a positive replica of the structure to be used as a permanent record or in the

More information

PREDICTABILITY IN COMPREHENSIVE RECONSTRUCTION Bite registration and recovery process for comprehensive reconstructive cases.

PREDICTABILITY IN COMPREHENSIVE RECONSTRUCTION Bite registration and recovery process for comprehensive reconstructive cases. PREDICTABILITY IN COMPREHENSIVE RECONSTRUCTION Bite registration and recovery process for comprehensive reconstructive cases. By Matt Roberts The most predictable comprehensive restorative techniques revolve

More information

Removable Prosthodontics. Complete Denture Procedures for a Team Approach

Removable Prosthodontics. Complete Denture Procedures for a Team Approach Department of General Dentistry Division of Removable Prosthodontics Complete Denture Procedures for a Team Approach For Competency #9 1 Rev. April 2010 Ronni A. Schnell, D.M.D., M.A.G.D. Complete Denture

More information

We express. Acrylics rich in color and texture. GENERAL PRODUCT INFORMATION

We express. Acrylics rich in color and texture. GENERAL PRODUCT INFORMATION We express Saint Basil Cathedral, Rusia. Visual riches for a changing aesthetic. Acrylics rich in color and texture. GENERAL PRODUCT INFORMATION Acrylic resins result from a mixture of powdered polymers

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8802 Convex Array Transducer English BB0334-I August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com Impression material Page 296 Laboratory accessories Page 298 Appliance containers and accessories Page 300 Orthodontic study / demonstration models Page 302 Other Page 307 292 . Reliability at a great

More information

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year ARAB AMERICAN UNIVERSITY Lab. Manual Prosthetic Dentistry1; Removable Prosthodontics 3 rd year Department of Fixed and removable prosthetic Dentistry Faculty of Dentistry 2012/2013 Course Instructor Dr.

More information

Review Article Techniques of Fabrication of Provisional Restoration: An Overview

Review Article Techniques of Fabrication of Provisional Restoration: An Overview International Dentistry Volume 2011, Article ID 134659, 5 pages doi:10.1155/2011/134659 Review Article Techniques of Fabrication of Provisional Restoration: An Overview K. M. Regish, Deeksha Sharma, and

More information

MM01-Facebow And Bite Registration Procedure Checklist

MM01-Facebow And Bite Registration Procedure Checklist MM01-Facebow And Bite Registration Procedure Checklist Bite fork Registration OK Redo 1. Estimate the shape of the patient s arch 2. Place the bite tabs on the bite fork 3. Warm the compound in hot water

More information

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38). NCB Proximal Humerus Plating System Surgical Technique 19 2. Temporary Plate Fixation The plate can be temporary fixed to the bone with 1.6mm K-wire through the proximal cannulated fixation screw of the

More information

Chairside Reference Guide

Chairside Reference Guide Chairside Reference Guide With this Chairside Reference Guide, you re on your way to efficiency and accuracy with LUMINEERS with LUMITray. As you familiarize yourself with the procedure, follow these

More information

Zimmer NexGen Trabecular Metal Tibial Tray

Zimmer NexGen Trabecular Metal Tibial Tray Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique Give Bone A Solid Hold Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique

More information

Leading material offering and application range. Straumann CARES CADCAM

Leading material offering and application range. Straumann CARES CADCAM Leading material offering and application range Straumann CARES CADCAM content Leading material offering 2 Applications at a glance 5 Features & benefits ceramics 6 Features & benefits metals 8 Features

More information

The CT Scanning Guide

The CT Scanning Guide The CT Scanning Guide and important step from planning to success Joachim Mosch, CDT, Christina Ketzinger, DT, Andreas Hoffmann, MDT Computer-supported or 3D implant planning is gaining ever-increasing

More information

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix NEW The SmartFix Concept Prosthetic solution on tilted implants SmartFix The SmartFix Concept Prosthetic solution on tilted implants The SmartFix Concept is an effective and time-saving technique for immediate

More information

DONGBAO PEN (ELECTRONIC) INSTRUCTION MANUAL

DONGBAO PEN (ELECTRONIC) INSTRUCTION MANUAL DONGBAO PEN (ELECTRONIC) INSTRUCTION MANUAL Foreword The new Dongbao Pen, which is made by Disetronic Medical Systems AG, is an injection aid incorporating the latest advances in technology. It is easy

More information

SS11LA Pneumotach Transducer

SS11LA Pneumotach Transducer BIOPAC Systems, Inc. 42 Aero Camino Goleta, CA 93117 Ph (805) 685-0066 Fax (805) 685-0067 www.biopac.com info@biopac.com SS11LA Pneumotach Transducer The SS11LA can be used to measure respiratory flow

More information

cement-retained single crowns using cementable abutments

cement-retained single crowns using cementable abutments cement-retained single crowns using cementable abutments cement-retained restorations cement-retained single crowns using cementable abutments Cement-retained implant restorations are similar to conventional

More information

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment The ITI (International Team for Implantology) is the academic partner of Institut Straumann in the areas of research and education.

More information

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV STERN ERA AND ERA-RV Summary Extracoronal semi-precision attachment. Universal hinge with vertical resiliency. Nylon male, plastic pattern female. Female is waxed into the pattern of the abutment restoration

More information

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE INDICATIONS FOR USE The LATERA Absorbable Nasal Implant is indicated for supporting upper and lower lateral nasal cartilage. CAUTION: Federal law restricts

More information

TECHNICAL DATASHEET POUR TYPE ACRYLIC RESIN PDFTPT-082

TECHNICAL DATASHEET POUR TYPE ACRYLIC RESIN PDFTPT-082 TCHNICAL DATASHT POUR TYP ACRYLIC RSIN 1 PRODUCT OVRVIW Methacrylate polymers have enjoyed great popularity in dentistry because they are easily processed by using relatively simple techniques; they have

More information