U-PLEX Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES.

Size: px
Start display at page:

Download "U-PLEX Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES."

Transcription

1 U-PLEX Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES v1-2007Mar

2 MSD U-PLEX Platform U-PLEX Metabolic Group 1 (Human) Multiplex Assays Tested on serum, plasma, P800 plasma, and cell culture supernatants. For use with: U-PLEX Metabolic Group 1 (hu) Assays (catalog numbers K151ACL-1, K151ACL-2, K151ACL-4) U-PLEX Metabolic Group 1 (hu) 87-Plex (catalog numbers K15280K-1, K15280K-2, K ) U-PLEX Metabolic Group 1 (hu) Combos. Catalog numbers for U-PLEX Metabolic Group 1 (hu) Combos are provided in Table 13 on page 21. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. MESO SCALE DISCOVERYP A division of Meso Scale Diagnostics, LLC Research Blvd. Rockville, MD USA MESO SCALE DISCOVERY, MESO SCALE DIAGNOSTICS, MSD, MSD GOLD, DISCOVERY WORKBENCH, MULTI-ARRAY, MULTI-SPOT, QUICKPLEX, SECTOR, SECTOR PR, SECTOR HTS, SULFO-TAG, R-PLEX, S-PLEX, T-PLEX, U-PLEX, V-PLEX, STREPTAVIDIN GOLD, MESO, SMALL SPOT (design), 96 WELL 1, 4, 7, 9, & 10-SPOT (designs), 384 WELL 1 & 4-SPOT (designs), MSD (design), R-PLEX (design), S-PLEX (design), T-PLEX (design), U-PLEX (design), V-PLEX (design), It s All About U, and SPOT THE DIFFERENCE are trademarks and/or service marks of Meso Scale Diagnostics, LLC Meso Scale Diagnostics, LLC. All rights reserved v2-2018Sep 2

3 Table of Contents Introduction... 4 Principle of the Assay... 5 Components... 6 Additional Materials and Equipment Safety Best Practices Reagent Preparation Assay Protocol Assay Performance Specificity Appendix Summary Protocol Plate Diagram Contact Information MSD Customer Service Phone: Fax: CustomerService@mesoscale.com MSD Scientific Support Phone: Fax: Attn: Scientific Support ScientificSupport@mesoscale.com v2-2018Sep 3

4 Introduction U-PLEX technology allows for the creation of custom multiplex assays for any combination of analytes by using two simple tools: a 10-spot U-PLEX plate and unique Linkers (Figure 1). The U-PLEX platform combines high sensitivity, up to 5 logs of linear dynamic range, a read time of less than 2 minutes, and the flexibility to create your own personalized multiplex assays. The U-PLEX assay menu is organized into groups, which include a broad menu of analytes assembled by species and analytical compatibility. As many as 10 U-PLEX assays from an assay group may be multiplexed on each plate for simultaneous quantification. For ultimate flexibility, custom combinations can be created from a selection of MSD U-PLEX assays, R-PLEX Antibody Sets, your own antibodies, or a combination. The U-PLEX Metabolic Group 1 (hu) contains 87 analytes (Table 1) that are important in many biological processes. These assays can detect secreted biomarkers in a variety of body fluids and cell culture supernatants where over- or under-expression may indicate a shift in the biological equilibrium. A representative data set for each assay is presented in the product-specific datasheets available at Table 1. Assays included in U-PLEX Metabolic Group 1 (hu) BAFF G-CSF IFN-γ IL-12p70 IL-29/IFN-λ1 PP BDNF Ghrelin (active) IL-1α IL-13 IL-31 Proinsulin β-ngf Ghrelin (total) IL-1β IL-15 IL-33 PYY (total) C-Peptide GIP (active) IL-1RA IL-16 Insulin SDF-1α (CXCL12) CTACK (CCL27) GIP (inactive) IL-2 IL-17A IP-10 (CXCL10) TARC (CCL17) ENA-78 (CXCL5) GIP (total) IL-2Rα IL-17A/F Leptin TNF-α Eotaxin (CCL11) GLP-1 (active) IL-3 IL-17C LH TNF-β Eotaxin-2 (CCL24) GLP-1 (inactive) IL-4 IL-17D MCP-1 (CCL2) TPO Eotaxin-3 (CCL26) GLP-1 (total) IL-5 IL-17E/IL-25 MCP-2 (CCL8) TRAIL EPO Glucagon IL-6 IL-17F MCP-4 (CCL13) TSLP FGF-21 GM-CSF IL-7 IL-18 M-CSF VEGF-A FGF-23 GRO-α (CXCL1) IL-8 (CXCL8) IL-21 MDC (CCL22) YKL-40 FLT3L I-309 (CCL1) IL-9 IL-22 MIF Fractalkine (CX3CL1) IFN-α2a IL-10 IL-23 MIP-1α (CCL3) FSH IFN-β IL-12/IL-23p40 IL-27 MIP v2-2018Sep 4

5 Principle of the Assay Biotinylated capture antibodies are coupled to U-PLEX Linkers, which self-assemble onto unique spots on the U-PLEX plate. Analytes in the sample bind to the capture reagents; detection antibodies conjugated with electrochemiluminescent labels (MSD GOLD SULFO-TAG) bind to the analytes to complete the sandwich immunoassay (Figure 1). Once the sandwich immunoassay is complete, the U-PLEX plate is loaded into an MSD instrument where a voltage applied to the plate electrodes causes the captured labels to emit light. The instrument measures the intensity of emitted light (which is proportional to the amount of analyte present in the sample) and provides a quantitative measure of each analyte in the sample. Figure 1. U-PLEX Immunoassay on a U-PLEX 10-Assay Plate v2-2018Sep 5

6 Components The following tables list the components provided with U-PLEX Metabolic Group 1 (hu) assays. You will only receive components relevant to the assays that you order. Reagents Supplied with All U-PLEX Metabolic Multiplex Assays Table 2. Reagents that are supplied with all U-PLEX Metabolic Group 1 (hu) assays Reagent Storage Catalog # Size Quantity Supplied 1 Plate 5 Plates 25 Plates Description Diluent C R56BB-4 10 ml 1 bottle Diluent for samples and Calibrators; contains serum, R56BB-3 50 ml 1 bottle 5 bottles blockers, and preservatives. Diluent C R55BA-5 10 ml 1 bottle Diluent for detection antibody; contains protein, blockers, and R55BA-3 50 ml 1 bottle 5 bottles preservatives. Aprotinin, 200,000 KIU/mL (200X) 2 8 C R93AD-1 50 µl 1 vial R93AD µl 1 vial 5 vial 200X concentrated solution. Stop Solution 2 8 C R50AO-1 40 ml 1 bottle 1 bottle 5 bottles Biotin-containing buffer to stop Linker-antibody coupling reaction. MSD GOLD Read Buffer RT R92TG-3 18 ml 1 bottle Buffer to catalyze the electrochemiluminescence reaction. R92TG-4 90 ml 1 bottle 5 bottles Assay-Specific Reagents 10-spot 96-well U-PLEX Plates U-PLEX assays use MSD 96-Well 10-Spot plates, provided in a sealed foil pouch with desiccant. The spots correspond to 10 unique U-PLEX Linkers. The number and layout of the active spots on the plate depends on the number of assays to be multiplexed (Figure 2). For example, if five assays are being multiplexed, the U-PLEX 5-Assay Plate will be provided. Figure 2. Spot Map of the different U-PLEX multiplex plates showing the placement of Linkers within a well. The colored spots represent the active U-PLEX binding spots. The numbering convention for the different spots is maintained in the software visualization tools, on the plate packaging, and in the data files. Note: In cases where there is a remainder of one assay, you will receive a U-PLEX 2-Assay plate. This will hold true for orders of 11, 21, 31 assays, and so on v2-2018Sep 6

7 Table 3. Part numbers and pack sizes for U-PLEX multiplex plates SECTOR Plates Part # Storage Number of Plates Supplied 1 Plate 5 Plates 25 Plates U-PLEX 2-Assay N05227A-1/-2/ C U-PLEX 3-Assay N05228A-1/-2/ C U-PLEX 4-Assay N05229A-1/-2/ C U-PLEX 5-Assay N05230A-1/-2/ C U-PLEX 6-Assay N05231A-1/-2/ C U-PLEX 7-Assay N05232A-1/-2/ C U-PLEX 8-Assay N05233A-1/-2/ C U-PLEX 9-Assay N05234A-1/-2/ C U-PLEX 10-Assay N05235A-1/-2/ C Linkers Based upon the number of assays you select for multiplexing, you will receive the corresponding number of unique Linkers (Table 5). Each Linker has a biotin-binding domain that couples to the biotinylated capture antibody, as well as a domain that binds to its matching spot on the U-PLEX plate. The Linkers are color coded and numbered with the spot to which they attach on the plate. 1-Plate packs include 300 µl of each Linker; 5-Plate packs include 1.8 ml of each Linker. 25-Plate packs include five vials of 1.8 ml of each Linker. Figure 3. Unique color-coded Linkers (10), Antibody Sets (10), and Calibrator vials (5) as shipped in a U-PLEX box v2-2018Sep 7

8 Table 4. U-PLEX Linker color-coding, storage conditions, part numbers, and size Name Color-coding Storage Part # Size U-PLEX Linker 1 U-PLEX Linker 2 U-PLEX Linker 3 U-PLEX Linker 4 U-PLEX Linker 5 U-PLEX Linker 6 U-PLEX Linker 7 U-PLEX Linker 8 U-PLEX Linker 9 U-PLEX Linker C 2 8 C 2 8 C 2 8 C 2 8 C 2 8 C 2 8 C 2 8 C 2 8 C 2 8 C E ml 1 vial Quantity Supplied 1 Plate 5 Plates 25 Plates E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials E ml 1 vial E ml 1 vial 5 vials Table 5. U-PLEX Linkers supplied with each pack Pack Name Linker 1 Linker 2 Linker 3 Linker 4 Linker 5 Linker 6 Linker 7 Linker 8 Linker 9 Linker 10 U-PLEX 1-Assay U-PLEX 2-Assay U-PLEX 3-Assay U-PLEX 4-Assay U-PLEX 5-Assay U-PLEX 6-Assay U-PLEX 7-Assay U-PLEX 8-Assay U-PLEX 9-Assay U-PLEX 10-Assay We recommend recording which antibody is coupled to each Linker when performing the coupling step (as described in the Reagent Preparation section) v2-2018Sep 8

9 U-PLEX Antibody Sets Based upon the analytes selected, you will receive U-PLEX Antibody Sets containing the biotinylated capture antibody and the SULFO-TAG conjugated detection antibody. The biotinylated capture antibody is provided at a ready-to-use concentration, and the SULFO-TAG conjugated detection antibody is provided at a 100X concentration. A complete list of Antibody Sets available for U-PLEX Metabolic Group 1 (hu) and their respective catalog numbers is provided in the Appendix (Table 14). Table 6. Contents of U-PLEX Antibody Set Name Storage Size U-PLEX Analyte-Specific Antibody Set Calibrators 2 8 C Quantity Supplied Description 1 Plate 5 Plates 25 Plates 1 Plate 1 Set containing biotinylated capture antibody and SULFO-TAG 5 Plate 1 5 conjugated detection antibody. Calibrators contain analytes that are lyophilized in a buffered diluent. Individual analyte concentrations are provided in the lot-specific certificates of analysis (COA). Depending on the specific assays requested, one or more of the following Calibrators will be provided. If combining calibrators, please refer to the Specificity section (page 18) for more information. Table 7. Analytes included in the Calibrator blends available for U-PLEX Metabolic Group 1 (hu) Name Storage Catalog # Size Quantity Supplied 1 Plate 5 Plates 25 Plates Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Calibrator C C vial 1 vial 5 vials 25 vials Assays GM-CSF, IFN-γ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-17A, TNF-α, VEGF-A Eotaxin, Eotaxin-3, IP-10, MCP-1, MCP-4, MDC, MIP-1α, MIP-1β, TARC G-CSF, IFN-α2a, IL-1α, IL-7, IL-12/IL-23p40, IL-15, IL-16, IL-18, TNF-β, TPO CTACK, ENA-78, Fractalkine, I-TAC, MIP-3α, MIP-3β, SDF-1α IL-17A/F, IL-17E/IL-25, IL-17F, IL-21, IL-22, IL-23, IL-27, IL-29/IFN-λ1, IL-31, IL-33, TSLP EPO, FLT3L, IFN-β, IL-1RA, IL-2Rα, IL-3, IL-9, IL-17B, IL-17C, IL-17D Eotaxin-2, GRO-α, I-309, MCP-2, MCP-3, M-CSF, MIF, MIP-5, TRAIL, YKL-40 FGF-21, Ghrelin (total), GIP (inactive), GIP (total), GLP-1 (inactive), GLP-1 (total), Glucagon, Leptin, PP, PYY (total) Calibrator C C vial 1 vial 5 vials 25 vials BAFF, BDNF, FGF-23, FSH, LH, β-ngf Calibrator C C vial 1 vial 5 vials 25 vials C-Peptide, Insulin Human Ghrelin (active) 2 8 C C016K-2 1 vial 1 vial 5 vials 25 vials Ghrelin (active) Human GIP (active) 2 8 C C016N-2 1 vial 1 vial 5 vials 25 vials GIP (active) GLP-1 (active) 2 8 C C016L-2 1 vial 1 vial 5 vials 25 vials GLP-1 (active) Human Proinsulin 2 8 C C016M-2 1 vial 1 vial 5 vials 25 vials Proinsulin v2-2018Sep 9

10 Additional Materials and Equipment Appropriately sized tubes for reagent preparation Polypropylene microcentrifuge tubes for preparing dilutions Liquid handling equipment suitable for dispensing 10 to 150 µl/well into a 96-well microtiter plate Plate washing equipment: automated plate washer or multichannel pipette Microtiter plate shaker (rotary) capable of shaking at 500 1,000 rpm MSD Wash Buffer (20X, 100 ml, catalog # R61AA-1) or Phosphate-buffered saline (PBS) plus 0.05% Tween-20 (PBS-T) for plate washing This size of MSD Wash Buffer is sufficient for washing 4 plates manually or for washing 2 plates with an automated plate washer Prepare a 1X working solution. For one plate, combine 15 ml of MSD Wash Buffer (20X) with 285 ml of deionized water. 1X MSD Wash Buffer can be stored at room temperature for up to two weeks. Adhesive plate seals Deionized water DPP-IV Inhibitor. Formulate and store as recommended by the manufacturer. Halt Protease Inhibitor Cocktail, EDTA-Free (Thermo Fisher Scientific, catalog number 87785). Recommended for Ghrelin (active) assay. Use as recommended by the manufacturer. Vortex mixer Safety Use safe laboratory practices: wear gloves, safety glasses, and lab coats when handling assay components. Handle and dispose of all hazardous samples properly in accordance with local, state, and federal guidelines. Additional product-specific safety information is available in the applicable safety data sheet(s) (SDS), which can be obtained from MSD Customer Service or at v2-2018Sep 10

11 Best Practices Bring frozen diluent to room temperature in a C water bath. Avoid cross-contamination between Linkers by following the techniques below: o Pulse centrifuge the vials to get all of the contents to the bottom of the vial. o Open one U-PLEX Linker vial at a time. Close the cap after use. o Each Linker vial is color coded; ensure that each cap and tube have matching colors when opening and closing vials. o Use filtered pipette tips. o Use a fresh pipette tip after each reagent addition. For long-term studies using multiple plates of the same assay, it is recommended that the same Linker be coupled with the same antibody for the duration of the study. While most lyophilized material is located at the bottom of the vial, some may be on the sides or cap. To ensure that all lyophilized powder is reconstituted, it is recommended to vortex the vial in 3 short pulses (upright, inverted, upright) after the solution sits at room temperature for minutes. Prepare Calibrator Standards and samples in polypropylene microcentrifuge tubes. Use a fresh pipette tip for each dilution and mix by vortexing after each dilution. Use reverse pipetting when necessary to avoid the introduction of bubbles. For empty wells, pipette gently to the bottom corner. Avoid prolonged exposure of the detection antibody (stock or diluted) to light. During the antibody incubation step, plates do not need to be shielded from light (except for direct sunlight). Avoid bubbles in wells during all pipetting steps as they may lead to variable results. Bubbles introduced when adding Read Buffer may interfere with signal detection. Plate shaking should be vigorous, with a rotary motion between 500 and 1,000 rpm. Binding reactions may reach equilibrium sooner if you use shaking at the middle of this range (~700 rpm) or above. Reversing plate orientation between wash cycles may improve assay precision. Gently tap the plate on a paper towel to remove residual fluid after washing. If you plan to coat U-PLEX plates for later use, keep each plate pouch and the desiccant that came with the plate. After the plates are incubated with the coating solution, wash them with MSD Wash Buffer or PBS-T, then return each plate to its original packaging with the desiccant, and seal. If an incubation step needs to be extended, leave the sample or detection antibody solution in the plate to keep the plate from drying out. Remove the plate seal prior to reading the plate. Make sure that the Read Buffer is at room temperature when added to a plate. Do not shake the plate after adding Read Buffer. To improve inter-plate precision, keep time intervals consistent between adding Read Buffer and reading the plate. Unless otherwise directed, read the plate as soon as possible after adding Read Buffer. If the sample results are above the top of the calibration curve, dilute the samples and repeat the assay v2-2018Sep 11

12 When running a partial plate, seal the unused sectors to avoid contaminating unused wells. Remove all seals before reading. The uncoated wells of a partially used plate may be sealed and stored up to 30 days at 2 8 C in the original foil pouch with desiccant. You may adjust volumes proportionally when preparing reagents. The components for assays that are larger than 10-plex or are otherwise provided in more than one box are specifically assembled so that each box contains fully compatible assay components. Each box includes one 10-spot U-PLEX plate (with the appropriate number of activated spots), Linkers, antibody pairs, and Calibrators that run optimally together. Components should not be mixed between boxes with the exception of Stop Solution, Diluents, and Read Buffer. For an example of a multi-plate assay, see the U-PLEX Metabolic Combo 1 (hu) Assay layout on page 25. Some assays are temperature sensitive. U-PLEX assays were characterized at C. Assays run above or below that range may be negatively impacted. Reagent Preparation Bring all reagents to room temperature and refer to the Best Practices section (page 11) before beginning the protocol. Important: Upon first thaw, aliquot Diluent 11 and Diluent 13 into suitable volumes before refreezing. To prepare MSD Wash Buffer and other supplemental reagents, please refer to the Additional Materials and Equipment section (page 10). Prepare U-PLEX Plate The preparation of a U-PLEX plate involves coating the provided plate with Linker-coupled capture antibodies. A U-PLEX 4-Assay plate is shown below as an example. This kit includes a plate with four activated spots at locations 1, 3, 8, and 10. Assign each antibody to a unique Linker and record the antibody identity next to the assigned Linker, as shown in the example below. Figure 4. A U-PLEX 4-Assay Plate, with recorded antibodies and assigned Linkers The protocol in this section describes the preparation of a multiplex coating solution for one 96-well plate. The volumes can be adjusted depending on the number of plates or wells, but the ratios of the reagents should remain the same (Table 8). STEP 1: Create Individual U-PLEX Linker-Coupled Antibody Solutions A different Linker must be used for each unique biotinylated antibody. Below are the steps to complete the coupling reactions for the above example of a 1-plate 4-plex assay. Couple each biotinylated capture antibody to a unique Linker and record the antibody identity next to the Linker number on the Spot Map (blank Spot Map is provided on page 26) v2-2018Sep 12

13 Add 200 µl of each biotinylated antibody to 300 µl of the assigned Linker in the Linker vial. Mix by vortexing. Incubate at room temperature for 30 minutes. Do not shake. If using a 5-plate Linker vial, combine each Linker with the biotinylated antibody in a new clean tube. Notes: Each Linker vial has a matching colored cap and label. To remove liquid from the cap, briefly centrifuge the Linker vial and open the cap gently. Open one Linker at a time and close its cap as soon as you are done using it. Take precautions to avoid reagent contamination. For studies using multiple plates of the same assay, it is recommended that the same Linker be coupled with the same antibody for the duration of the study. Add 200 µl of Stop Solution. Mix by vortexing. Incubate at room temperature for 30 minutes. Note: At the end of Step 1, each individual U-PLEX Linker-coupled antibody solution is at 10X the coating concentration and can be stored at 2-8 C. Do not store for more than 7 days. Adjust the volumes for multiple plates (see Table 8). The volumetric ratio of Linker: antibody: Stop Solution is 3:2:2. STEP 2: Prepare the Multiplex Coating Solution Combine 600 µl of each U-PLEX Linker-coupled antibody solution (10X) into a single tube and vortex. Up to 10 U-PLEX Linker-coupled antibodies can be pooled. Do not combine U-PLEX Linker-coupled antibody solutions that share the same Linker. When combining fewer than 10 antibodies, bring the solution up to 6 ml with Stop Solution. This will result in a final 1X concentration. Mix by vortexing. For example, for a 4-assay coating solution, add 3.6 ml of Stop Solution to the 2.4 ml of combined antibodies. Note: At the end of Step 2, the U-PLEX multiplex coating solution is at 1X and can be stored at 2-8 C. Do not store for more than 7 days. STEP 3: Coat the U-PLEX Plate Add 50 µl of multiplex coating solution to each well. Seal the plate with an adhesive plate seal and incubate with shaking at room temperature for 1 hour. The plate may also be shaken overnight, while incubating at 2 8 C. Wash the plate 3 times with at least 150 µl/well of 1X MSD Wash Buffer or PBS-T (PBS plus 0.05% Tween-20). The plate is now coated and ready for use. Coated plates may be stored in the original pouch with desiccant and sealed, for up to 7 days at 2 8 C. The recommended volumes of Linker, biotinylated capture antibody, and Stop Solution for coating one or multiple U-PLEX plates are provided below. If using a partial plate (fewer than 96 wells), refer to Table 15 in the Appendix. Table 8. Amount of each component required for U-PLEX coating solution per plate No. of Plate(s) Individual Linker ( µl) Individual Biotinylated Antibody (µl) Stop Solution (µl) , ,500 1,000 1,000 N 300 x N 200 x N 200 x N v2-2018Sep 13

14 Prepare Metabolic Assay Working Solution This is used for preparing the calibrator, controls, and diluting the samples. For one plate, combine the following in a 15 ml tube: 6,965 µl of Diluent µl of Aprotinin Notes: 1. Addition of DPP-IV inhibitor (not provided) to a final concentration of 0.1 mm in the Metabolic Assay Working Solution is strongly recommended. DPP-IV inhibitor will aid in limiting enzymatic action of DPP-IV present in serum/plasma and provides the most accurate measurement of some metabolic analytes. 2. Ghrelin (active) assay only: Addition of Halt Protease Inhibitor Cocktail, EDTA-Free (Thermo Fisher Scientific, cat. no ) to a final concentration of 1X in the Metabolic Assay Working Solution is strongly recommended. The presence of Halt inhibitor may impact sample quantitation in other assays. Important: Protease inhibitors should be added prior to use. The Metabolic Assay Working Solution should be kept on ice. Do not freeze the Metabolic Assay Working Solution for later use. Prepare Calibrator Standards Depending on the assays ordered, you may receive one or more Calibrator vials with your order. If combining calibrators, please refer to the Specificity section (page 18) for more information. The following instructions will enable you to prepare eight Calibrator Standards (7 calibrator solutions plus a zero calibrator) for up to four replicates. Bring the Calibrator vial(s) to room temperature. Reconstitute each vial of Calibrator by adding 250 µl of Metabolic Assay Working Solution to the glass vial. This will result in a 10X concentrated stock of each Calibrator, which will need to be diluted 10-fold (per the instructions given below) to generate the highest point in the standard curve (i.e., Calibrator Standard 1). Invert the reconstituted Calibrator at least 3 times. Do not vortex. Let the solution equilibrate at room temperature for minutes and then vortex briefly. This will result in a 10X concentrated stock of the Calibrator. Dilute the 10X Calibrator stock solution. o o For single Calibrator standard curves, add 25 µl of the 10X stock to 225 µl of Metabolic Assay Working Solution to generate the highest point in the standard curve (i.e., Calibrator Standard 1). The Calibrator is now ready for use. To blend multiple Calibrators, follow Table 9, and mix by vortexing briefly. Keep dilutions at room temperature. Note: We recommend that reconstituted Calibrators be used immediately. If storage is necessary, divide into 60 µl aliquots and store immediately at -70 C. For the lot-specific concentration of each calibrator in the blend, refer to the COA supplied with the product. You can also find a copy of COA at v2-2018Sep 14

15 Table 9. Combining Calibrators to generate the Calibrator Standard 1 (top of the curve) level # of Calibrator Blends Provided Volume of Reconstituted Calibrator (µl) Assay Diluent (µl) Total volume (µl) each each each each N 25 each *N 250 Prepare the subsequent 6 dilutions for the curve (4-fold serial dilutions) in Metabolic Assay Working Solution (see Table 10 for an example). Use Metabolic Assay Working Solution for the Calibrator Standard 8 (zero Calibrator/blank). Mix by vortexing the tubes between each serial dilution. Figure 5. Dilution schema for preparation of Calibrator Standards for U-PLEX Metabolic Group 1 (hu) assays Table 10. Serial dilution to generate the standard curve Calibrator Standard # Tube # 1 1 Source of Calibrator Calibrator Standard 1 (top of curve) Volume of Reconstituted Calibrator (µl) Assay Diluent (µl) See Table 9 Total volume (µl) 2 2 From tube From tube From tube From tube From tube From tube (zero Calibrator) Note: In certain situations, 5-fold serial dilutions may be desired and can be made by transferring 60 µl of reconstituted Calibrator into 240 µl of Assay Diluent instead of the volumes noted in Table v2-2018Sep 15

16 Sample Collection and Handling Below are general guidelines for sample collection, storage, and handling for metabolic markers. We strongly suggest following these procedures if working with the active forms of protein analytes. If other methods are used, evaluate sample stability under the selected method as needed. The assay requires 50 µl/well of the sample. Based on the number of replicates desired, prepare adequate volume of the sample. Sample Collection (preferred method): Samples should be collected using the BD P800 Collection and Preservation System, which contains DPP-IV and other protease inhibitors (Product Number or ). The alternative collection method described below with K2EDTA tubes can also be used. Non-P800 collection method: Collect blood in BD Vacutainer K2EDTA Tubes (Product Number or ). Immediately add DPP-IV inhibitor (0.1 mm final concentration, not provided) and aprotinin (1,000 KIU/mL final concentration) and mix to avoid cleavage/degradation of metabolic peptides. For BD tubes, process as follows: In a swing out rotor centrifuge, spin the blood collection tubes as follows; o o For 2 ml tubes - 10 minutes at 1,000 x g (2 8 C). For 8.5 and 10 ml tubes - 20 minutes at 1,300 x g (2 8 C). Use the plasma immediately or the samples can be stored at 2 8 C if used within 3 hours. For future use, aliquot the plasma and freeze in suitably-sized aliquots at -70ºC. For samples other than serum and plasma, add DPP-IV inhibitor (0.1 mm final concentration, not provided) and aprotinin (1,000 KIU/mL final concentration) and use immediately or freeze at -70 C. Samples with hemolysis or significant lipemia may hinder accurate measurements. Repeated freezing and thawing of samples is not recommended. After thawing, centrifuge samples at 2,000g for 3 minutes to remove particulates prior to using in the assay. If the samples are clear and no particulates are visible, you may not need to centrifuge. Hold on wet ice or 2 8 C until processed and used in the assay. Dilute Samples Depending on the sample set under investigation, a dilution may be necessary. Metabolic Assay Working Solution may be used for sample dilution. The dilution factor for the given sample type needs to be optimized. Note: For MIF, MIP-5, and YKL-40, data indicate that a larger sample dilution may be required to generate optimal results. Refer to the product-specific datasheets for additional information. Prepare Detection Antibody Solution The detection antibody is provided as a 100X stock solution. The working solution is 1X. Prepare the detection antibody solution immediately prior to use. Adjust the volumes proportionally for partial plates. For one plate, combine: 60 µl of each 100X detection antibody Diluent 11 to bring the final volume to 6 ml v2-2018Sep 16

17 Read Buffer MSD provides MSD GOLD Read Buffer ready for use. Do not dilute. Important: Unlike Read Buffer T, which is provided at a 4X concentration, MSD GOLD Read Buffer is provided at the working concentration of the assay. Dilution of MSD GOLD Read Buffer may compromise the results of the assay. Assay Protocol Note: Follow Reagent Preparation before beginning this assay protocol. STEP 1: Add Samples and Calibrators Add 50 µl of the prepared Calibrator Standard or sample to each well. Seal the plate with an adhesive plate seal. Incubate at room temperature with shaking for 2 hours. STEP 2: Wash and Add Detection Antibody Solution Wash plate 3 times with at least 150 µl/well of 1X MSD Wash Buffer or PBS-T. Add 50 µl of detection antibody solution to each well. Seal the plate with an adhesive plate seal. Incubate at room temperature with shaking for 1 hour. STEP 3: Wash and Read Wash the plate 3 times with at least 150 µl/well of 1X MSD Wash Buffer or PBS-T. Add 150 µl of MSD GOLD Read Buffer to each well. Analyze the plate on an MSD instrument. Incubation in Read Buffer is not required before reading the plate. Alternate Protocols The suggestions below may be useful for simplifying the protocol. Alternate Protocol 1, Extended Incubation: Incubating samples overnight at 2 8 C with shaking may improve sensitivity for some assays. Alternate Protocol 2, Reduced Wash: For cell culture supernatants, you may simplify the protocol by eliminating one of the wash steps. After incubating the Calibrator Standard or sample, add detection antibody solution to the plate without decanting or washing the plate. Assay Performance A representative data set for each assay is presented in the product-specific datasheets available at The data represent performance of the assay tested in multiplex format on U-PLEX plates. The data were generated during the development of the assay and do not represent the product specifications. Under your experimental conditions and with your specific multiplex, the assay may perform differently than the representative data shown v2-2018Sep 17

18 Specificity To assess specificity, the Antibody Set for each assay in the group was tested individually against a larger panel of antibodies and recombinant human analytes for nonspecific binding (BAFF, BDNF, β-ngf, C-Peptide, CTACK, ENA-78, Eotaxin, Eotaxin-2, Eotaxin-3, EPO, FGF-21, FGF-23, FLT3L, Fractalkine, FSH, G-CSF, Ghrelin (Ser3-octanoylated), Desghrelin, GIP (1 42), GIP (3 42), GLP-1 (7 36), GLP-1 (9 36), Glucagon, GM-CSF, GRO-α, I-309, IFN-α2a, IFN-β, IFN-γ, IL-1α, IL-1β, IL-1RA, IL-2, IL-2Rα, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IL-17A/F, IL-17C, IL-17D, IL-17E/IL-25, IL-17F, IL-18, IL-21, IL-22, IL-23, IL-27, IL-29/IFN-λ1, IL-31, IL-33, Insulin, IP-10, Leptin, LH, MCP-1, MCP-2, MCP-4, M-CSF, MDC, MIF, MIP-1α, MIP-5, PP, Proinsulin (25 110), PYY (3 36), SDF-1α, TARC, TNF-α, TNF-β, TPO, TRAIL, TSLP, VEGF-A, and YKL-40). Nonspecific binding was less than 0.5% for all assays included in the U-PLEX Metabolic Group 1 (hu) using the following calculation. % NNNNNNNNNNNNNNNNNNNNNNNNNNNN = nnnnnnnnnnnnnnnnnnnnnn ssssssssssss 100 ssssssssssssssss ssssssssssss Exceptions are noted below, along with guidance when combining calibrators. Some exceptions are expected based on the structural similarity of the analytes. 1. The Proinsulin analyte cross-reacts 27% with the C-Peptide assay, the Insulin analyte cross-reacts 0.5% with the C-Peptide assay, and the C-Peptide analyte cross-reacts 0.7% with the Proinsulin assay. We do not recommend multiplexing the Insulin or C-Peptide assays with the Proinsulin assay on the same plate. The Proinsulin Calibrator should not be combined with Calibrator The Desghrelin analyte cross-reacts 0.5% with the Ghrelin (active) assay. The Octanoylated Ghrelin analyte cross-reacts with the Ghrelin (total) assay as expected. We do not recommend multiplexing the Ghrelin (total) and Ghrelin (active) assays on the same plate. If measuring the Ghrelin (total) assay, the Human Ghrelin (active) Calibrator should not be combined with Calibrator The GIP (active) analyte cross-reacts with the GIP (total) assay as expected, and 2.4% with the GIP (inactive) assay. We do not recommend multiplexing GIP (active), GIP (inactive), or GIP (total) assays on the same plate. If measuring the GIP (inactive) or GIP (total) assays, Human GIP (active) Calibrator should not be combined with Calibrator The GLP-1 (active) analyte cross-reacts with the GLP-1 (total) assay, the GLP-1 (inactive) analyte cross-reacts with the GLP-1 (total) assay as expected. We do not recommend multiplexing GLP-1 (active) or GLP-1 (inactive) assays with the GLP-1 (total) assay on the same plate. If measuring the GLP-1 (total) assay, Human GLP-1 (active) Calibrator should not be combined with Calibrator The IL-12p70 and IL-23 analytes contain the p40 subunit. These analytes will cross-react with the IL-12/IL-23p40 assay as expected. We do not recommend multiplexing IL-12p70 or IL-23 assays on the same plate with the IL-12/IL-23p40 assay. If measuring IL-12/IL-23p40 assay, Calibrator 3 should not be combined with either Calibrator 1 or The IL-17A analyte cross-reacts with the IL-17A/F assay. The IL-17A/F analyte cross-reacts with the IL-17A assay. We do not recommend multiplexing these assays on the same plate. If measuring IL-17A or IL-17A/F assays, Calibrator 6 should not be combined with Calibrator The MCP-2 detection antibody non-specifically binds the Eotaxin Calibrator (2.8%). We do not recommend multiplexing the MCP-2 assay and the Eotaxin assay on the same plate. 8. The PYY (total) detection antibody cross-reacts with the PP analyte (1.1%) v2-2018Sep 18

19 Appendix Calibration U-PLEX assays are calibrated against a reference calibrator generated at MSD. MSD reference calibrators for the following analytes were evaluated against the NIBSC/WHO International Standards; the ratios of NIBSC/WHO standard relative to MSD calibrator are shown in the table below. To convert MSD concentrations to biological activity relative to the WHO International Standard, multiply the MSD concentration by the ratio provided. Table 11. Ratios of NIBSC/WHO Standards relative to MSD Calibrators Analyte U-PLEX Calibrator NIBSC/WHO Cat. # NIBSC/WHO Unit MSD Unit NIBSC/WHO : MSD BDNF Calibrator 14 96/534 U/mL pg/ml β-ngf Calibrator 14 93/556 U/mL pg/ml C-Peptide Calibrator 15 84/510 pg/ml pg/ml 1 Glucagon Calibrator 13 69/194 IU/mL pm 3.46 x 10-9 Insulin Calibrator 15 83/500 µiu/ml µiu/ml 1 Leptin Calibrator 13 97/594 IU/mL pg/ml LH Calibrator 14 81/535 µiu/ml µiu/ml 1 Proinsulin Proinsulin 09/296 µg/ml pm 9.43 x 10-6 Calibrator Conversion Factors For most assays, the calibrator concentration provided in the COA is in pg/ml. GLP-1 (active, inactive, total), Glucagon, and Proinsulin are provided in pm units, and a factor to convert each to pg/ml is provided in the table below. FSH, Insulin, and LH are provided in units/ml, and no conversion factor is available. Table 12. Calibrator concentration conversion factors Assay pm to pg/ml GLP-1 (active) 1 pm 3.30 pg/ml GLP-1 (inactive) 1 pm 3.09 pg/ml GLP-1 (total) 1 pm 3.09 pg/ml Glucagon 1 pm 3.48 pg/ml Proinsulin 1 pm 9.39 pg/ml v2-2018Sep 19

20 Notes regarding the following assays 1. BDNF, β-ngf, C-Peptide, LH, Proinsulin: The U-PLEX Human BDNF, β-ngf, C-Peptide, LH, and Proinsulin Assays have been anchored to NIBSC/WHO standards. Please see Table 11 for conversion factors. 2. Insulin: The U-PLEX Human Insulin Assay has been anchored to NIBSC/WHO standard 83/500. Please see Table 11 for conversion factors. The U-PLEX Human Insulin Assay uses a different format and protocol than previous MSD assays for insulin. In a limited study with samples comparing the U-PLEX Human Insulin Assay to previous MSD insulin assays, the observed concentrations of the samples were on average within 20% for similar protocols. The data were insufficient to support a general, single-factor conversion between the assays and we recommend that users transitioning from previous MSD insulin assays carry out a standard concordance study. 3. GLP-1 (active): The U-PLEX Human GLP-1 (active) Assay has been developed with better sensitivity than our previous GLP-1 (active) assays and the Calibrator has been anchored to an internal standard for sustainability. When comparing samples, the U-PLEX Human GLP-1 (active) Assay will report concentrations that are approximately 30% lower than the previous MSD Active GLP-1 (ver. 2) assay. 4. GLP-1 (total): The U-PLEX Human GLP-1 (total) Assay has been designed to eliminate a bias towards the active fragment of GLP-1 that was observed in the previous MSD Total GLP-1 (ver. 2) assay. The U-PLEX Human GLP-1 (total) Assay detects both active and inactive fragments of GLP-1 equivalently and enables improved quantitation of total GLP-1 in samples. Because of these changes, concentrations of samples will not correlate between the U-PLEX Human GLP-1 (total) Assay and the previous MSD Total GLP-1 (ver. 2) assay. 5. Glucagon: The U-PLEX Human Glucagon Assay has been anchored to NIBSC/WHO standard 69/194. Please see Table 11 for conversion factors. Compared to previous versions of the assay, the U-PLEX Human Glucagon Assay has significantly improved sensitivity and dynamic range and enables measurement of native levels of glucagon in 100% of samples collected in P800 tubes. The measured concentrations of samples may not correlate between the U-PLEX Human Glucagon Assay and previous MSD glucagon assays. We recommend that users transitioning from previous MSD glucagon assays carry out a standard concordance study. 6. Leptin: The U-PLEX Human Leptin Assay has been anchored to NIBSC/WHO standard 97/594. Please see Table 11 for conversion factors. The U-PLEX Human Leptin assay was designed to improve sensitivity compared to previous versions of MSD leptin assays. The measured concentrations of samples may not correlate between the U-PLEX Human Leptin Assay and previous MSD leptin assays. We recommend that users transitioning from previous MSD leptin assays carry out a standard concordance study. Please contact MSD Scientific Support for further information v2-2018Sep 20

21 U-PLEX Combos U-PLEX Combos (pre-configured multiplexes) include U-PLEX Plates, Linkers, Antibody Sets, Calibrators, Stop Solution, diluents, and Read Buffer. Table 13. Catalog numbers of U-PLEX Metabolic Group 1 (hu) multiplex combinations Product U-PLEX Metabolic Group 1 (hu) 87-Plex U-PLEX Adipokine Combo 1 (hu) U-PLEX Diabetes Combo 1 (hu) U-PLEX Diabetes Combo 2 (hu) U-PLEX Metabolic Combo 1 (hu)* Assays BAFF, BDNF, β-ngf, C-Peptide, CTACK (CCL27), ENA-78 (CXCL5), Eotaxin (CCL11), Eotaxin-2 (CCL24), Eotaxin-3 (CCL26), EPO, FGF-21, FGF-23, FLT3L, FSH, Fractalkine (CX3CL1), G-CSF, Ghrelin (active), Ghrelin (total), GIP (active), GIP (inactive), GIP (total), GLP-1 (active), GLP-1 (inactive), GLP-1 (total), Glucagon, GM-CSF, GRO-α (CXCL1), I-309 (CCL1), IFN-α2a, IFN-β, IFN-γ, IL-1α, IL-1β, IL-1RA, IL-2, IL-2Rα, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8 (CXCL8), IL-9, IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IL-17A/F, IL-17C, IL-17D, IL-17E/IL-25, IL-17F, IL-18, IL-21, IL-22, IL-23, IL-27, IL-29/IFN-λ1, IL-31, IL-33, Insulin, IP-10 (CXCL10), Leptin, LH, MCP-1 (CCL2), MCP-2 (CCL8), MCP-4 (CCL13), M-CSF, MDC (CCL22), MIF, MIP-1α (CCL3), MIP-5, PP, Proinsulin, PYY (total), SDF-1α (CXCL12), TARC (CCL17), TNF-α, TNF-β, TPO, TRAIL, TSLP, VEGF-A, YKL-40 BDNF, β-ngf, IL-1β, IL-6, IL-8, IL-10, Insulin, Leptin, MCP-1, TNF-α C-Peptide, GIP (total), GLP-1 (total), Glucagon, Insulin, Leptin, PYY (total) C-Peptide, GIP (total), GLP-1 (active), Glucagon, Insulin, Leptin, PYY (total) BAFF, BDNF, β-ngf, C-Peptide, FGF-21, FGF-23, FSH, Ghrelin (active), Ghrelin (total), GIP (active), GIP (inactive), GIP (total), GLP-1 (active), GLP-1 (inactive), GLP-1 (total), Glucagon, Insulin, Leptin, LH, PP, Proinsulin, PYY (total) Insulin, Leptin U-PLEX Metabolic 2-Plex Combo 1 (hu) U-PLEX Metabolic 3-Plex GLP-1 (active), Glucagon, Insulin Combo 1 (hu) U-PLEX Metabolic 4-Plex GLP-1 (active), Glucagon, Insulin, Leptin Combo 1 (hu) U-PLEX Obesity Combo 1 BDNF, FGF-21, Ghrelin (total), Glucagon, Leptin (hu) U-PLEX Obesity Combo 2 C-Peptide, FGF-23, Ghrelin (total), GLP-1 (total), Insulin, Leptin, PYY (total) (hu) *See additional instructions on page 25 to run this assay. Catalog Numbers (-1/-5/-25 Plate Size) K15280K-1/-2/-4 K15276K-1/-2/-4 K15274K-1/-2/-4 K15275K-1/-2/-4 K15281K-1/-2/-4 K15282K-1/-2/-4 K15283K-1/-2/-4 K15284K-1/-2/-4 K15277K-1/-2/-4 K15278K-1/-2/ v2-2018Sep 21

22 U-PLEX Antibody Sets Antibody Sets include a biotinylated capture antibody and SULFO-TAG conjugated detection antibody. Table 14. Catalog numbers of U-PLEX Metabolic Group 1 (hu) Antibody Sets Product Catalog Numbers (-1/-5 Plate Size) Product Catalog Numbers (-1/-5 Plate Size) U-PLEX Human BAFF Antibody Set B216C-2/-3 U-PLEX Human IL-12/IL-23p40 Antibody Set B21UQ-2/-3 U-PLEX Human BDNF Antibody Set B216W-2/-3 U-PLEX Human IL-12p70 Antibody Set B21UA-2/-3 U-PLEX Human β-ngf Antibody Set B216D-2/-3 U-PLEX Human IL-13 Antibody Set B21UB-2/-3 U-PLEX Human C-Peptide Antibody Set B216J-2/-3 U-PLEX Human IL-15 Antibody Set B21UR-2/-3 U-PLEX Human CTACK Antibody Set B21VD-2/-3 U-PLEX Human IL-16 Antibody Set B21US-2/-3 U-PLEX Human ENA-78 Antibody Set B21VE-2/-3 U-PLEX Human IL-17A Antibody Set B21UT-2/-3 U-PLEX Human Eotaxin Antibody Set B21UD-2/-3 U-PLEX Human IL-17A/F Antibody Set B21VY-2/-3 U-PLEX Human Eotaxin-2 Antibody Set B21XQ-2/-3 U-PLEX Human IL-17C Antibody Set B21WJ-2/-3 U-PLEX Human Eotaxin-3 Antibody Set B21UE-2/-3 U-PLEX Human IL-17D Antibody Set B21XO-2/-3 U-PLEX Human EPO Antibody Set B21VX-2/-3 U-PLEX Human IL-17E/IL-25 Antibody Set B21VZ-2/-3 U-PLEX Human FGF-21 Antibody Set B215W-2/-3 U-PLEX Human IL-17F Antibody Set B21WA-2/-3 U-PLEX Human FGF-23 Antibody Set B216E-2/-3 U-PLEX Human IL-18 Antibody Set B21VJ-2/-3 U-PLEX Human FLT3L Antibody Set B21XF-2/-3 U-PLEX Human IL-21 Antibody Set B21WB-2/-3 U-PLEX Human Fractalkine Antibody Set B21VC-2/-3 U-PLEX Human IL-22 Antibody Set B21WI-2/-3 U-PLEX Human FSH Antibody Set B216G-2/-3 U-PLEX Human IL-23 Antibody Set B21WG-2/-3 U-PLEX Human G-CSF Antibody Set B21VG-2/-3 U-PLEX Human IL-27 Antibody Set B21WC-2/-3 U-PLEX Human Ghrelin (active) Antibody Set B216K-2/-3 U-PLEX Human IL-29/IFN-λ1 Antibody Set B21WD-2/-3 U-PLEX Human Ghrelin (total) Antibody Set B215X-2/-3 U-PLEX Human IL-31 Antibody Set B21WE-2/-3 U-PLEX Human GIP (active) Antibody Set B216N-2/-3 U-PLEX Human IL-33 Antibody Set B21WF-2/-3 U-PLEX Human GIP (inactive) Antibody Set B215T-2/-3 U-PLEX Human Insulin Antibody Set B216H-2/-3 U-PLEX Human GIP (total) Antibody Set B215S-2/-3 U-PLEX Human IP-10 Antibody Set B21UF-2/-3 U-PLEX Human GLP-1 (active) Antibody Set B216L-2/-3 U-PLEX Human Leptin Antibody Set B215Z-2/-3 U-PLEX Human GLP-1 (inactive) Antibody Set B215V-2/-3 U-PLEX Human LH Antibody Set B216F-2/-3 U-PLEX Human GLP-1 (total) Antibody Set B215U-2/-3 U-PLEX Human MCP-1 Antibody Set B21UG-2/-3 U-PLEX Human Glucagon Antibody Set B215Y-2/-3 U-PLEX Human MCP-2 Antibody Set B21XH-2/-3 U-PLEX Human GM-CSF Antibody Set B21UM-2/-3 U-PLEX Human MCP-4 Antibody Set B21UH-2/-3 U-PLEX Human GRO-α Antibody Set B21UX-2/-3 U-PLEX Human M-CSF Antibody Set B21XR-2/-3 U-PLEX Human I-309 Antibody Set B21UY-2/-3 U-PLEX Human MDC Antibody Set B21UI-2/-3 U-PLEX Human IFN-α2a Antibody Set B21VH-2/-3 U-PLEX Human MIF Antibody Set B21XJ-2/-3 U-PLEX Human IFN-β Antibody Set B21VI-2/-3 U-PLEX Human MIP-1α Antibody Set B21UJ-2/-3 U-PLEX Human IFN-γ Antibody Set B21TT-2/-3 U-PLEX Human MIP-5 Antibody Set B21XS-2/-3 U-PLEX Human IL-1α Antibody Set B21UN-2/-3 U-PLEX Human PP Antibody Set B216A-2/-3 U-PLEX Human IL-1β Antibody Set B21TU-2/-3 U-PLEX Human Proinsulin Antibody Set B216M-2/-3 U-PLEX Human IL-1RA Antibody Set B21XP-2/-3 U-PLEX Human PYY (total) Antibody Set B216B-2/-3 U-PLEX Human IL-2 Antibody Set B21TV-2/-3 U-PLEX Human SDF-1α Antibody Set B21VB-2/-3 U-PLEX Human IL-2Rα Antibody Set B21XG-2/-3 U-PLEX Human TARC Antibody Set B21UL-2/-3 U-PLEX Human IL-3 Antibody Set B21XM-2/-3 U-PLEX Human TNF-α Antibody Set B21UC-2/-3 U-PLEX Human IL-4 Antibody Set B21TW-2/-3 U-PLEX Human TNF-β Antibody Set B21UU-2/-3 U-PLEX Human IL-5 Antibody Set B21UO-2/-3 U-PLEX Human TPO Antibody Set B21VK-2/-3 U-PLEX Human IL-6 Antibody Set B21TX-2/-3 U-PLEX Human TRAIL Antibody Set B21XT-2/-3 U-PLEX Human IL-7 Antibody Set B21UP-2/-3 U-PLEX Human TSLP Antibody Set B21WH-2/-3 U-PLEX Human IL-8 Antibody Set B21TY-2/-3 U-PLEX Human VEGF-A Antibody Set B21UV-2/-3 U-PLEX Human IL-9 Antibody Set B21XK-2/-3 U-PLEX Human YKL-40 Antibody Set B21VL-2/-3 U-PLEX Human IL-10 Antibody Set B21TZ-2/ v2-2018Sep 22

23 Working with Partial Plates A portion of a plate (fewer than 96 wells) may be used. Volumes should be adjusted proportionally when preparing reagents for partial plates. For convenience, the recommended volumes of Linker, biotinylated capture antibody, and Stop Solution for coating partial plates are provided below. Table 15. Amount of each component required for U-PLEX coating solution (partial plate) Individual Linker Individual Biotinylated Stop Solution per Vol. to Pull from Each No. of Wells (µl) Antibody (µl) Reaction (µl) Reaction (µl) When running a partial plate, seal the unused sectors to avoid contaminating unused wells. Remove all seals before reading. The uncoated wells of a partially used plate may be sealed and stored for up to 30 days at 2 8 C in the original foil pouch with desiccant v2-2018Sep 23

24 Cross-species Reactivity Cross-species reactivity of 22 metabolic assays was assessed using either plasma, P800 plasma, serum, or species-specific proteins (if available). The table below reports the cross-species reactivity (+: cross-reactive; -: not cross-reactive) for each assay. Table 16. Cross-species reactivity to U-PLEX Metabolic Combo 1 (hu) Assays Assay NHP Mouse Rat Canine BAFF BDNF β-ngf C-Peptide FGF FGF FSH Ghrelin (active) Ghrelin (total) GIP (active) GIP (inactive) GIP (total) GLP-1 (active) GLP-1 (inactive) GLP-1 (total) Glucagon Insulin Leptin LH PP Proinsulin PYY (total) v2-2018Sep 24

25 Multi-plate Assays Multiplex U-PLEX assays can occupy more than one plate, depending on the number and compatibility of the selected assays. Preconfigured multiplexes, including Combos and Metabolic Groups, are arranged in optimal layouts, with compatible assays and Calibrators packaged together along with adequate linkers and an activated U-PLEX plate. Components of a multi-plate assay should not be mixed between boxes, with the exception of Stop Solution, Diluents, and Read Buffer. An example of a multi-plate U-PLEX assay is the U-PLEX Metabolic Combo 1 (hu) (cat. no. K15281K). The assay is supplied in three separate U-PLEX boxes. Each box includes one 10-spot U-PLEX plate (with the appropriate number of activated spots), Linkers, antibody pairs, and Calibrators that run optimally together. Components should not be mixed between boxes, with the exception of Stop Solution, Diluents, and Read Buffer. To perform the U-PLEX Metabolic Combo 1 (hu) assay, we recommend that you position the three boxes as shown in the table below. When multiple Calibrators are in one box, they should be blended as instructed in this product insert. Do not combine with any other Calibrators from another box. There will be a unique Calibrator curve for each box. Table 17. U-PLEX Metabolic Combo 1 (hu) Assay Layout Box 1 10-Assay Plate Box 2 8-Assay Plate Box 3 4-Assay Plate C-Peptide BAFF GIP (active) FGF-21 BDNF Ghrelin (active) Ghrelin (total) FGF-23 GLP-1 (active) GIP (total) FSH Proinsulin GLP-1 (total) Glucagon Insulin Leptin PP PYY (total) LH β-ngf GIP (inactive) GLP-1 (inactive) Calibrators 13, 15 Calibrators 13, 14 4 Individual Calibrators v2-2018Sep 25

26 Summary Protocol Prepare U-PLEX Plates STEP 1: Create Individual U-PLEX Linker-Coupled Antibody Solutions Couple an individual biotinylated antibody to a unique Linker, and record the antibody identity next to the Linker number on the Spot Map (Figure 6). Add 200 µl of each biotinylated antibody to 300 µl of the assigned Linker. Refer to the U-PLEX plate Spot Map to determine which Linkers can be combined. A different Linker must be used for each unique biotinylated antibody. Mix by vortexing. Incubate at room temperature for 30 minutes. Add 200 µl of Stop Solution. Mix by vortexing. Incubate at room temperature for 30 minutes. STEP 2: Prepare the Multiplex Coating Solution Combine 600 µl of each U-PLEX Linker-coupled antibody solution into a single tube and mix by vortexing. Up to 10 U-PLEX Linker-coupled antibodies can be pooled. Do not combine U-PLEX Linker-coupled antibody solutions that share the same Linker. When combining fewer than 10 antibodies, bring the solution up to 6 ml by mixing with Stop Solution to result in a final 1X concentration. Mix by vortexing. STEP 3: Coat the U-PLEX Plates Add 50 µl of multiplex coating solution to each well. Seal the plate with an adhesive plate seal and shake for 1 hour at room temperature. Alternatively, you can shake the plate overnight while incubating at 2 8 C. Wash the plate 3 times with at least 150 µl/well of 1X Wash Buffer or PBS-T. The plate is now coated and ready for use. Spot Map Figure 6. Spot map v2-2018Sep 26

27 Assay Protocol STEP 1: Add Sample and Calibrator Standards Add 50 µl of the prepared Calibrator Standard or sample to each well. Seal the plate with an adhesive plate seal. Incubate at room temperature with shaking for 2 hours. STEP 2: Wash and Add Detection Antibody Solution Wash plate 3 times with at least 150 µl/well of 1X MSD Wash Buffer or PBS-T. Add 50 µl of detection antibody solution to each well. Seal the plate with an adhesive plate seal. Incubate at room temperature with shaking for 1 hour. STEP 3: Wash and Read Wash the plate 3 times with at least 150 µl/well of 1X MSD Wash Buffer or PBS-T. Add 150 µl of MSD GOLD Read Buffer to each well. Analyze the plate on an MSD instrument. Incubation in Read Buffer is not required before reading the plate. Plate Diagram Figure 7. Plate diagram v2-2018Sep 27

U-PLEX Custom Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES.

U-PLEX Custom Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. U-PLEX Custom Metabolic Group 1 (Human) Multiplex Assays FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. 17379-v1-2007Mar MSD U-PLEX Platform U-PLEX Custom Metabolic Group 1

More information

Human Total GIP Kit v1-2016Apr 1

Human Total GIP Kit v1-2016Apr 1 Human Total GIP Kit 1-Plate Kit 5-Plate Kit 25-Plate Kit K151RPD-1 K151RPD-2 K151RPD-4 18067-v1-2016Apr 1 MSD Metabolic Assays Human Total GIP Kit This package insert must be read in its entirety before

More information

MULTI-ARRAY. 1-Plate Kit 5-Plate Kit 25-Plate Kit

MULTI-ARRAY. 1-Plate Kit 5-Plate Kit 25-Plate Kit MESO SCALE DISCOVERY MULTI-ARRAY Assay System Active GLP-1 (ver. 2) Assay Kit 1-Plate Kit 5-Plate Kit 25-Plate Kit K150JWC-1 K150JWC-2 K150JWC-4 MESO SCALE DISCOVERY MESO SCALE DISCOVERY MESO SCALE DISCOVERY

More information

RayBio Human Thyroglobulin ELISA Kit

RayBio Human Thyroglobulin ELISA Kit RayBio Human Thyroglobulin ELISA Kit Catalog #: ELH-Thyroglobulin User Manual Last revised July 6, 2017 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite

More information

RayBio Human ENA-78 ELISA Kit

RayBio Human ENA-78 ELISA Kit RayBio Human ENA-78 ELISA Kit Catalog #: ELH-ENA78 User Manual Last revised April 15, 2016 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures. Rat Insulin ELISA For the quantitative determination of insulin in rat serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: Size: 80-INSRT-E01, E10 96 wells, 10

More information

Porcine/Canine Insulin ELISA

Porcine/Canine Insulin ELISA Porcine/Canine Insulin ELISA For the quantitative determination of insulin in porcine or canine serum and plasma. Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research

More information

Bovine Insulin ELISA

Bovine Insulin ELISA Bovine Insulin ELISA For quantitative determination of insulin in bovine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 80-INSBO-E01 Size: 96 wells Version:

More information

Mouse C-peptide ELISA

Mouse C-peptide ELISA Mouse C-peptide ELISA For the quantitative determination of C-peptide in mouse serum. For Research Use Only. Not for use in Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calculation

More information

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum Rat C-peptide ELISA For the quantitative determination of C-peptide in rat serum Please read carefully due to Critical Changes, e.g., see Calculation of Results. For Research Use Only. Not For Use In Diagnostic

More information

Insulin (Porcine/Canine) ELISA

Insulin (Porcine/Canine) ELISA Insulin (Porcine/Canine) ELISA For the quantitative measurement of insulin in Porcine/Canine serum and plasma (EDTA) For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 80-INSPO-E01

More information

Mouse C-peptide ELISA

Mouse C-peptide ELISA Mouse C-peptide ELISA For the quantitative determination of C-peptide in mouse serum. For Research Use Only. Not for use in Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Preparation

More information

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0201 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The GLP-1 (Glucagon-like Peptide 1) Enzyme

More information

Mouse Ultrasensitive Insulin ELISA

Mouse Ultrasensitive Insulin ELISA Mouse Ultrasensitive Insulin ELISA For the quantitative determination of insulin in mouse serum and plasma. Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research Use

More information

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures. Rat C-peptide ELISA For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: Size: 80-CPTRT-E01 96 wells Version: May 26,

More information

Rat Proinsulin ELISA

Rat Proinsulin ELISA Rat Proinsulin ELISA For the quantitative determination of proinsulin in rat serum For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 80-PINRT-E01 Size: 96 wells Version: June

More information

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures. TNF-alpha ELISA For the quantitative determination of TNF-alpha in serum, plasma, buffered solution or cell culture medium. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number:

More information

GLP-1 Total Kit FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. V-PLEX. V-PLEX Plus GLP-1 Total K1503PD K1503PG

GLP-1 Total Kit FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. V-PLEX. V-PLEX Plus GLP-1 Total K1503PD K1503PG GLP-1 Total Kit V-PLEX V-PLEX Plus GLP-1 Total K1503PD K1503PG FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. 17379-v1-2007Mar MSD Metabolic Assays GLP-1 Total Kit For use

More information

Mouse C-Peptide ELISA Kit

Mouse C-Peptide ELISA Kit Mouse C-Peptide ELISA Kit Cat.No: DEIA4507 Lot. No. (See product label) Size 96T Intended Use The Mouse C-Peptide ELISA kit is for the quantitative determination of c-peptide in mouse serum, plasma, and

More information

Human TSH ELISA Kit. User Manual

Human TSH ELISA Kit. User Manual Human TSH ELISA Kit User Manual Catalog number: GTX15585 GeneTex Table of Contents A. Product Description... 2 B. Kit Components... 3 C. Additional Required Materials (not included)... 3 D. Reagent Preparation...

More information

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2 For detection and measurement of human interleukin 2 Catalog #02006 Catalog #02007 2 Plates 10 Plates Product Description The Human Interleukin 2 (IL-2) ELISA Kit is designed for the quantitative detection

More information

ab Insulin Human ELISA Kit

ab Insulin Human ELISA Kit Version 9 Last updated 29 September 2017 ab100578 Insulin Human ELISA Kit For the quantitative measurement of human Insulin and Proinsulin in serum, plasma, cell culture supernatants. This product is for

More information

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Insulin ELISA. For the quantitative determination of insulin in serum and plasma. Insulin ELISA For the quantitative determination of insulin in serum and plasma. For In Vitro Diagnostic use within the United States of America. This product is for Research Use Only outside of the United

More information

MULTI-SPOT. Mouse/Rat Active GLP-1, Insulin, Glucagon Kit. 1-Plate Kit 5-Plate Kit 20-Plate Kit

MULTI-SPOT. Mouse/Rat Active GLP-1, Insulin, Glucagon Kit. 1-Plate Kit 5-Plate Kit 20-Plate Kit Meso Scale Discovery MULTI-SPOT Assay System Mouse/Rat Active GLP-1, Insulin, Glucagon Kit 1-Plate Kit 5-Plate Kit 20-Plate Kit K15172C-1 K15172C-2 K15172C-3 Meso Scale Discovery Meso Scale Discovery Meso

More information

ab Thyroglobulin Human ELISA Kit

ab Thyroglobulin Human ELISA Kit ab155441 Thyroglobulin Human ELISA Kit Instructions for Use For the quantitative measurement of Human Thyrogobulin in serum, plasma and cell culture supernatants. This product is for research use only

More information

Human HIV (1+2) antigen&antibody ELISA Kit

Human HIV (1+2) antigen&antibody ELISA Kit Human HIV (1+2) antigen&antibody ELISA Kit Catalog Number. CSB-E18042h For the qualitative determination of human HIV (1+2) antibody and P24 antigen concentrations in serum, plasma. This package insert

More information

GLP-1 Active Kit FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. V-PLEX GLP-1 Active. V-PLEX Plus.

GLP-1 Active Kit FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. V-PLEX GLP-1 Active. V-PLEX Plus. GLP-1 Active Kit V-PLEX GLP-1 Active K1503OD V-PLEX Plus K1503OG FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. 17379-v1-2007Mar MSD Metabolic Assays GLP-1 Active Kit For use

More information

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C Phospho-Stat3 (ptyr 705 ) and pan-stat3 ELISA Kit for detection of human, mouse, or rat phospho-stat3 (ptyr 705 ) and pan-stat3 in cell and tissue lysates Catalog Number RAB0447 Storage Temperature 20

More information

Human Neuropeptide Y (NPY) ELISA KIT

Human Neuropeptide Y (NPY) ELISA KIT Human Neuropeptide Y (NPY) ELISA KIT Cat. No.:DEIA7404 Pkg.Size:96T Intended use The Human Neuropeptide Y (NPY) ELISA KIT is used for the non-radioactive quantification of Neuropeptide Y (NPY) in human

More information

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

Insulin ELISA. For the quantitative determination of insulin in serum and plasma Insulin ELISA For the quantitative determination of insulin in serum and plasma For In Vitro Diagnostic use within the United States of America. This product is for Research Use Only outside of the United

More information

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit Catalog #: PEL-NFKBP65-S536-T User Manual Last revised October 10, 2017 Caution: Extraordinarily useful information

More information

Electrolytes. Summary: (This area will include a brief description of what the protocol is used for and why someone would need to use it.

Electrolytes. Summary: (This area will include a brief description of what the protocol is used for and why someone would need to use it. Electrolytes Version: 1 Edited by: Jason Kim (note that the following list should be linked to the appropriate location.) Summary Reagents and Materials Protocol Reagent Preparation Reagent 1 Reagent 2

More information

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates Catalog Number RAB0011 Storage Temperature 20 C TECHNICAL BULLETIN Product Description

More information

Nori Rabbit IL-2 ELISA Kit DataSheet

Nori Rabbit IL-2 ELISA Kit DataSheet Nori Rabbit IL-2 ELISA Kit DataSheet IL-2 is an interleukin, a type of cytokine immune system signaling molecule. IL-2 is a T cell stimulatory cytokine best known for inducing T cell proliferation, the

More information

TECHNICAL BULLETIN. C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0326 Storage Temperature 20 C

TECHNICAL BULLETIN. C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0326 Storage Temperature 20 C C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0326 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The C-Peptide Enzyme Immunoassay (EIA)

More information

Human Obestatin ELISA

Human Obestatin ELISA K-ASSAY Human Obestatin ELISA For the quantitative determination of obestatin in human serum and plasma Cat. No. KT-495 For Research Use Only. 1 Rev. 081309 K-ASSAY PRODUCT INFORMATION Human Obestatin

More information

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phosphotyrosine BTK ELISA Kit RayBio Human Phosphotyrosine BTK ELISA Kit Catalog #: PEL-BTK-Y User Manual Last revised August 10, 2016 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite

More information

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit Catalog Number KA2176 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Principle of the Assay...

More information

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit Catalog No: E0442h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Canine Thyroid Stimulating Hormone, TSH ELISA Kit Canine Thyroid Stimulating Hormone, TSH ELISA Kit Catalog No: E0463c 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

RayBio Human Granzyme B ELISA Kit

RayBio Human Granzyme B ELISA Kit RayBio Human Granzyme B ELISA Kit Catalog #: ELH-GZMB User Manual Last revised April 15, 2016 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

STAT1 (ps727) (Human/Mouse) ELISA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit STAT1 (ps727) (Human/Mouse) ELISA Kit Catalog Number KA2171 96 assays Version: 01 Intended for research use only www.abnova.com I. INTRODUCTION STAT1 (ps727) (Human/Mouse) ELISA (Enzyme-Linked Immunosorbent

More information

Exendin-4 (Exenatide) ELISA Kit

Exendin-4 (Exenatide) ELISA Kit Exendin-4 (Exenatide) ELISA Kit Catalog: DEIABL227 For the quantitative determination of Exendin-4 in serum or plasma using competitive ELISA method For Research Use Only. Protocol Provided for Informational

More information

STELLUX C-peptide Chemiluminescence ELISA

STELLUX C-peptide Chemiluminescence ELISA STELLUX C-peptide Chemiluminescence ELISA For the quantitative determination of Human C-peptide in Human Serum, Heparin Plasma, EDTA plasma, and Tissue Culture Supernatants. For In Vitro Diagnostic use

More information

Procine sphingomyelin ELISA Kit

Procine sphingomyelin ELISA Kit Procine sphingomyelin ELISA Kit For the quantitative in vitro determination of Procine sphingomyelin concentrations in serum - plasma - celiac fluid - tissue homogenate - body fluid FOR LABORATORY RESEARCH

More information

Morinaga Mouse C-peptide ELISA Kit

Morinaga Mouse C-peptide ELISA Kit Morinaga Mouse C-peptide ELISA Kit For the quantitative determination of C-peptide in mouse serum, plasma, and fluid 96wells For Laboratory Use Only, not for use in diagnostic procedure Please read full

More information

EliKine Free Thyroxine (ft4) ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit EliKine Free Thyroxine (ft4) ELISA Kit Booklet Item NO. KET0005 Product Name EliKine Free Thyroxine (ft4) ELISA Kit ATTENTION For laboratory research use only. Not for clinical or diagnostic use TABLE

More information

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit Catalog #: PEL-DDR1-Y792-T User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607

More information

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit Catalog #: PEL-DDR2-Y740-T User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607

More information

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet Interleukin5 (IL5) is a secreted glycoprotein that belongs to the α-helical group of cytokines (1, 2, 3). Unlike other family members, it is present as a covalently linked antiparallel dimer (4, 5). IL-5

More information

TECHNICAL BULLETIN. Ghrelin EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0207 Storage Temperature 20 C

TECHNICAL BULLETIN. Ghrelin EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0207 Storage Temperature 20 C Ghrelin EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0207 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The Ghrelin EIA (Enzyme Immunoassay) Kit

More information

Proinsulin (Total) Chemiluminescence ELISA

Proinsulin (Total) Chemiluminescence ELISA Proinsulin (Total) Chemiluminescence ELISA For the quantitative determination of proinsulin in human serum, EDTA plasma, heparin plasma, and tissue culture supernatants For In Vitro Diagnostic use within

More information

Human Thyroid Stimulating Hormone CLIA kit

Human Thyroid Stimulating Hormone CLIA kit Human Thyroid Stimulating Hormone CLIA kit Cat. No.:DEEL0223 Pkg.Size:96 tests Intended use For the direct quantitative determination of Thyroid Stimulating Hormone in human serum by chemiluminescence

More information

Prothrombin (Human) ELISA Kit

Prothrombin (Human) ELISA Kit Prothrombin (Human) ELISA Kit Catalog Number KA0496 96 assays Version: 04 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay... 3 General

More information

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit Catalog #: PEL-DDR1-Y792 User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane,

More information

Chemokine Panel 1 (human) Kits

Chemokine Panel 1 (human) Kits Chemokine Panel 1 (human) Kits Eotaxin, MIP-1β, Eotaxin-3, TARC, IP-10, MIP-1α, IL-8, MCP-1, MDC, MCP-4 V-PLEX V-PLEX Plus Multiplex Kits K15047D K15047G Individual Assay Kits Human Eotaxin K151NSD K151NSG

More information

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN YK051 Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC. 2480-1 AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN 418 0011 Contents Introduction 2 Characteristics 3 Composition 4 Method 5-6 Notes

More information

Insulin Chemiluminescence ELISA

Insulin Chemiluminescence ELISA Insulin Chemiluminescence ELISA For the quantitative determination of insulin in human Serum, Heparin Plasma, and Tissue Culture Supernatants. For In Vitro Diagnostic use within the United States of America.

More information

Insulin Rodent (Mouse/Rat) Chemiluminescence ELISA

Insulin Rodent (Mouse/Rat) Chemiluminescence ELISA Insulin Rodent (Mouse/Rat) Chemiluminescence ELISA For the quantitative determination of insulin in rodent serum, plasma, and tissue culture supernatants. For Research use Only. Not For Use In Diagnostic

More information

HbA1c (Human) ELISA Kit

HbA1c (Human) ELISA Kit HbA1c (Human) ELISA Kit Cat. No.:DEIA3509 Pkg.Size:96T Intended use GHbA1c (Human) ELISA Kit is a sandwich enzyme immunoassay for the quantitative measurement of human GHbA1c. General Description vhemoglobin,

More information

FOR LABORATORY USE ONLY

FOR LABORATORY USE ONLY YK060 Insulin ELISA FOR LABORATORY USE ONLY Kasumigaseki Place, 3-6-7, Kasumigaseki, Chiyoda-ku Tokyo 100-0013 Japan URL: http://www.sceti.co.jp/export/ e-mail: medical@sceti.co.jp Contents

More information

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN YK050 Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC. 2480-1 AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN 418-0011 Contents Introduction 2 Characteristics 3 Composition 4 Method 5-6 Notes

More information

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit STAT3 (py705) (Human/Mouse/Rat) ELISA Kit Catalog Number KA2175 96 assays Version: 01 Intended for research use only www.abnova.com I. INTRODUCTION STAT3 (py705) (Human/Mouse/Rat) ELISA (Enzyme-Linked

More information

ab Human Citrate Synthase (CS) Activity Assay Kit

ab Human Citrate Synthase (CS) Activity Assay Kit ab119692 Human Citrate Synthase (CS) Activity Assay Kit Instructions for Use For the measurement of mitochondrial citrate synthase (CS) activity in Human samples This product is for research use only and

More information

Rat cholesterol ELISA Kit

Rat cholesterol ELISA Kit Rat cholesterol ELISA Kit Catalog No. CSB-E11706r (96T) This immunoassay kit allows for the in vitro quantitative determination of rat Cholesterol concentrations in serum, plasma and other biological fluids.

More information

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit Catalog No. E0228r (96 tests) Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS!

More information

AssayMax Human Aldose Reductase ELISA Kit

AssayMax Human Aldose Reductase ELISA Kit AssayMax Human Aldose Reductase ELISA Kit Assaypro LLC 3400 Harry S Truman Blvd St. Charles, MO 63301 T (636) 447-9175 F (636) 395-7419 www.assaypro.com For any questions regarding troubleshooting or performing

More information

Data Sheet. CD28:B7-2[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Data Sheet. CD28:B7-2[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions Data Sheet CD28:B7-2[Biotinylated] Inhibitor Screening Assay Kit Catalog # 72062 Size: 96 reactions BACKGROUND: The activation of naïve T cells requires two signals; the specific T cell receptor recognition

More information

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit EGFR (py1045)/ Pan EGFR (Human) ELISA Kit Catalog Number KA2156 96 assays Version: 01 Intended for research use only www.abnova.com I. INTRODUCTION EGFR (py1045)/pan EGFR (Human) ELISA (Enzyme-Linked Immunosorbent

More information

human Total Cathepsin B Catalog Number: DY2176

human Total Cathepsin B Catalog Number: DY2176 human Total Cathepsin B Catalog Number: DY2176 This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human Total

More information

CoQ10(Coenzyme Q10) ELISA Kit

CoQ10(Coenzyme Q10) ELISA Kit CoQ10(Coenzyme Q10) ELISA Kit Catalogue No.: EU0196 Size: 48T/96T Reactivity: Universal Detection Range: 0.781-50ng/ml Sensitivity:

More information

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No.

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No. K-ASSAY KAMIYA BIOMEDICAL COMPANY KAMIYA BIOMEDICAL COMPANY Estrone EIA kit For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media Cat. No. KT-720 For Research

More information

Human LDL ELISA Kit. Innovative Research, Inc.

Human LDL ELISA Kit. Innovative Research, Inc. Human LDL ELISA Kit Catalog No: IRKTAH2582 Lot No: SAMPLE INTRODUCTION Human low-density lipoprotein (LDL) transports cholesterol from the liver to tissues where it is incorporated into cell membranes.

More information

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma GLP-2 (Rat) ELISA For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 48-GP2RT-E01

More information

ab Human Hemoglobin subunit alpha SimpleStep ELISA Kit

ab Human Hemoglobin subunit alpha SimpleStep ELISA Kit Version 1 Last updated 7 March 2017 ab219049 Human Hemoglobin subunit alpha SimpleStep ELISA Kit For the quantitative measurement of Hemoglobin subunit alpha in human serum, plasma, cerebral spinal fluid,

More information

Human Alpha 1 microglobulin ELISA Kit

Human Alpha 1 microglobulin ELISA Kit Human Alpha 1 microglobulin ELISA Kit Catalogue No.: EH4144 Size: 48T/96T Reactivity: Human Range:0.625-40ng/ml Sensitivity:

More information

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use. Definitions Instructions for use REF Catalogue number IV2-113E Use by English Invitron Glargine ELISA Kit For in-vitro diagnostic use Σ 96 LOT IVD Lot/Batch Code Storage temperature limitations In vitro

More information

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY Mouse C-peptide EIA Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY TOYO 2CHOME, KOTO-KU, TOKYO, 135-0016, JAPAN http://www.cosmobio.co.jp e-mail : export@cosmobio.co.jp Phone : +81-3-5632-9617 FAX : +81-3-5632-9618

More information

Human Apolipoprotein A1 EIA Kit

Human Apolipoprotein A1 EIA Kit A helping hand for your research Product Manual Human Apolipoprotein A1 EIA Kit Catalog Number: 83901 96 assays 1 Table of Content Product Description 3 Assay Principle 3 Kit Components 3 Storage 4 Reagent

More information

PYY (Human/Mouse/Rat) ELISA Kit

PYY (Human/Mouse/Rat) ELISA Kit PYY (Human/Mouse/Rat) ELISA Kit Catalog Number KA1686 96 assays Version: 05 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay... 3

More information

Human IL-2 ELISA Antibody Pair

Human IL-2 ELISA Antibody Pair Human IL-2 ELISA Antibody Pair For the qualitative and quantitative determination of IL-2 in serum, plasma and cell culture. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number:

More information

Mouse Cathepsin B ELISA Kit

Mouse Cathepsin B ELISA Kit GenWay Biotech, Inc. 6777 Nancy Ridge Drive San Diego, CA 92121 Phone: 858.458.0866 Fax: 858.458.0833 Email: techline@genwaybio.com http://www.genwaybio.com Mouse Cathepsin B ELISA Kit Catalog No. GWB-ZZD154

More information

Human, Rat, Mouse Melanin Concentrating Hormone (MCH) ELISA Kit

Human, Rat, Mouse Melanin Concentrating Hormone (MCH) ELISA Kit Human, Rat, Mouse Melanin Concentrating Hormone (MCH) ELISA Kit Cat. No.:DEIA10659 Pkg.Size:96T Intended use The Human, Rat, Mouse Melanin Concentrating Hormone (MCH) ELISA Kit is intended for the detection

More information

Data Sheet. PCSK9[Biotinylated]-LDLR Binding Assay Kit Catalog # 72002

Data Sheet. PCSK9[Biotinylated]-LDLR Binding Assay Kit Catalog # 72002 Data Sheet PCSK9[Biotinylated]-LDLR Binding Assay Kit Catalog # 72002 DESCRIPTION: The PCSK9[Biotinylated]-LDLR Binding Assay Kit is designed for screening and profiling purposes. PCSK9 is known to function

More information

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples.

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples. GLP-2 ELISA For the quantitative determination of GLP-2 in human serum and plasma samples. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 48-GP2HU-E01.1 Size: 96 wells Version:

More information

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev. Mouse GLP-2 EIA For the quantitative determination of GLP-2 in mouse serum or plasma. Cat. No. KT-374 For Research Use Only. 1 Rev. 11357374 PRODUCT INFORMATION Mouse GLP-2 EIA Cat. No. KT-374 INTENDED

More information

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids DATA SHEET EXOTESTTM ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids INTRODUCTION Exosomes are small endosome-derived lipid nanoparticles

More information

Rat Leptin 96-Well Plate Assay Cat. # EZRL-83K

Rat Leptin 96-Well Plate Assay Cat. # EZRL-83K Rat Leptin 96-Well Plate Assay Cat. # EZRL-83K RAT LEPTIN ELISA KIT 96-Well Plate (Cat. # EZRL-83K) I. Intended Use 2 II. Principles Of Procedure 2 III. Reagents Supplied 2 IV. Storage and Stability 4

More information

Human IL-2. Pre-Coated ELISA Kit

Human IL-2. Pre-Coated ELISA Kit Human IL-2 (Interleukin 2) Pre-Coated ELISA Kit Catalog No: 90-2083 1 96 well Format (96 tests) Detection Range: 31.2 2000 pg/ml Sensitivity: < 18.75 pg/ml This immunoassay kit allows for the in vitro

More information

INTACT HUMAN PROINSULIN ELISA KIT 96-Well Plate (Cat. # EZHIPI-17K )

INTACT HUMAN PROINSULIN ELISA KIT 96-Well Plate (Cat. # EZHIPI-17K ) INTACT HUMAN PROINSULIN ELISA KIT 96-Well Plate (Cat. # EZHIPI-17K ) I. Intended Use 2 II. Principles Of Procedure 2 III. Reagents Supplied 2 IV. Storage and Stability 4 V. Reagent Precautions 4 VI. Materials

More information

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research. Rat IL-2 ELISA Kit Instructions for use Catalogue numbers: 1x96 tests: 670.100.096 2x96 tests: 670.100.192 For research use only Fast Track Your Research. Table of Contents 1. Intended use 2 2. Introduction

More information

YK052 Mouse Leptin ELISA

YK052 Mouse Leptin ELISA YK052 Mouse Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC. 2480-1 AWAKURA, FUJINOMIYA-SHI SHIZUOKA, JAPAN 418-0011 Contents Ⅰ. Introduction 2 Ⅱ. Characteristics 3 Ⅲ. Composition 4 Ⅳ. Method

More information

RayBio Human/Mouse/Rat GIP Enzyme Immunoassay Kit

RayBio Human/Mouse/Rat GIP Enzyme Immunoassay Kit RayBio Human/Mouse/Rat GIP Enzyme Immunoassay Kit Please Read the Manual Carefully Before Starting your Experiment User Manual 2.2 (Revised March 15, 2012) RayBio GIP Enzyme Immunoassay Kit Protocol (Cat#:

More information

C-Peptide I and II (Rat) ELISA

C-Peptide I and II (Rat) ELISA C-Peptide I and II (Rat) ELISA For the quantitative determination of rat C-peptide in plasma, serum, urine, and cell culture supernatant Please read carefully due to Critical Changes, e.g., blot plate

More information

Serum Amyloid A ELISA

Serum Amyloid A ELISA Serum Amyloid A ELISA For the quantitative determination of serum amyloid A (SAA) in serum plasma For Research use Only. Not for Use in Diagnostic Procedures Please see Appendix A for Reference Serum information

More information

Mouse Leptin ELISA Kit Instructions

Mouse Leptin ELISA Kit Instructions V.6/Mar/2008 CRYSTAL CHEM INC. Mouse Leptin ELISA Kit Instructions For the quantitative determination of leptin in mouse serum or plasma and fluid Catalog #: 90030 96 Assays For Research Use Only. Not

More information

For the quantitative determination of Glucagon concentrations in cell culture supernates, serum and plasma.

For the quantitative determination of Glucagon concentrations in cell culture supernates, serum and plasma. Glucagon ELISA Kit Cat.No: DEIA2827 Lot. No. (See product label) Size 96T Intended Use For the quantitative determination of Glucagon concentrations in cell culture supernates, serum and plasma. General

More information

ab Hemoglobin Human ELISA Kit

ab Hemoglobin Human ELISA Kit Version 3 Last updated 22 September 2017 ab157707 Hemoglobin Human ELISA Kit For the quantitative measurement of Hemoglobin in Human serum and plasma samples. This product is for research use only and

More information

SIV p27 Antigen ELISA Catalog Number:

SIV p27 Antigen ELISA Catalog Number: INTENDED USE The RETRO-TEK SIV p27 Antigen ELISA is for research use only and is not intended for in vitro diagnostic use. The RETRO-TEK SIV p27 Antigen ELISA is an enzyme linked immunoassay used to detect

More information