Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana
|
|
- Posy Hopkins
- 6 years ago
- Views:
Transcription
1 Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana
2
3
4
5
6
7
8
9
10
11 IS THERE STILL A ROLE FOR THE MANUAL BLOOD COUNT?
12
13
14 Indication for examination of a blood smear Bain BJ. Diagnosis from the blood smear. N Engl J Med. 2005;353(5):
15 The blood counters
16 Principles of cell counters n Light absorption n Light scatter n Impedance n Fluorescence n Electrical conductivity
17 Hemoglobin photometry Probe Cellpack PhotoSensor Diode Lens Filter Cuvette Photosensor 17
18 WBC Count: Light scattering
19 ADVIA: RBC/PLT channel
20 The RBC method
21 The Coulter principle
22 Coulter principle
23 Impedance Widerstand Gleichspannungsquelle (ca. 100 V) konst. Gleichstrom Vakuum externe Elektrode interne Elektrode Kapillaröffnung Blutzellen Blutsuspension 23
24 Impedance Opening of the capillary external electrode internal electrode Vacuum
25 Impedance Opening of the capillary external Electrode internal Electrode U = R x I U = Voltage I = Current R = Resistance
26 Impedance Opening of the capillary external Electrode internal Electrode U=R x I U = Voltage I = Current R = Resistance
27 Volumen [fl] Impedance Mixing chamber Vorlauf Impulse/Volumen Zeit [sec] Zählzeit Nachlauf (definiertes Volumen) RBC Sheath Injektionspumpe (Schrittmotor betrieben) Hauptventil Hüllstrom Abfallkammer verdünnte Blutprobe 27
28 Technologies employed for the differential counts Instrument and manufacturer Coulter Sysmex ADVIA Cobas Technology employed for differential count Impedance with low- and high-frequency electromagnetic current Laser light scattering Impedance with low-frequency direct current Impedance with radiofrequency current Light scattering Absorbance (Peroxydase) Electrical impedance Light absorbance
29 Advanced systems ACAS = Adaptive cluster analysis system VCS = Volume/Conductivity/Scatter
30 COMPARABILITY OF THE CELL COUNTERS
31 Difference Plot 60% Identity WBC Difference (advia2120i WBC (10E09/L) - advia120.wbc (10E9/L)) / Mean of All 40% 20% 0% -20% -40% -60% Bias (1.0%) 95% Limits of agreement (-10.9% to 13.0%) ADVIA120 vs. ADVIA % Mean of All Difference Plot 60% Identity Bias (-0.1%) Difference (beckman DxH 800.WBC (10E9/L) - advia120.wbc (10E9/L)) / Mean of All 40% 20% 0% -20% -40% -60% 95% Limits of agreement (-14.6% to 14.4%) ADVIA120 vs. DxH800-80% Mean of All Difference Plot 60% Identity Bias (1.8%) Difference (sysmex XT4000i.WBC (10E9/L) - advia120.wbc (10E9/L)) / Mean of All 40% 20% 0% -20% -40% -60% 95% Limits of agreement (-9.1% to 12.7%) ADVIA120 vs. XE4000i -80% Mean of All
32 Difference Plot 200% Identity RBC Difference (advia 2120i.RBC (10E12/L) - advia120.rbc (10E12/L)) / Mean of All 150% 100% 50% 0% Bias (-0.7%) 95% Limits of agreement (-20.3% to 18.9%) ADVIA120 vs. ADVIA % Mean of All Difference Plot 200% Identity Difference (beckman DxH 800.RBC (10E12/L) - advia120.rbc (10E12/L)) / Mean of All 150% 100% 50% 0% Bias (-1.9%) 95% Limits of agreement (-21.8% to 18.0%) ADVIA120 vs. DxH800-50% Mean of Difference All Plot 200% Identity Bias (-0.5%) Difference (sysmex XT4000i.RBC (10E12/L) - advia120.rbc (10E12/L)) / Mean of All 150% 100% 50% 0% 95% Limits of agreement (-20.0% to 19.1%) ADVIA120 vs. XE4000i -50% Mean of All
33 Difference Plot Hemoblobin Difference (advia 2120i.HGB (g/dl) - advia120.hgb (g/dl)) / Mean of All 20% 15% 10% 5% 0% -5% -10% -15% -20% -25% -30% Mean of All Difference Plot 20% 15% Identity Bias (0.8%) 95% Limits of agreement (-4.4% to 5.9%) ADVIA120 vs. ADVIA2120 Identity Bias (-1.0%) Difference (beckman DxH 800.HGB (g/dl) - advia120.hgb (g/dl)) / Mean of All 10% 5% 0% -5% -10% -15% -20% -25% -30% Mean of All 95% Limits of agreement (-4.8% to 2.9%) ADVIA120 vs. DxH800 Difference (sysmex XT4000i.HGB (g/dl) - advia120.hgb (g/dl)) / Mean of All Difference Plot 20% 15% 10% 5% 0% -5% -10% -15% -20% -25% Identity Bias (0.4%) 95% Limits of agreement (-3.4% to 4.2%) ADVIA120 vs. XE4000i -30% Mean of All
34 Difference Plot 80% Identity Platelets Difference (advia 2120i PLT (10E09/L) - advia120.plt (10E9/L)) / Mean of All 60% 40% 20% 0% -20% -40% -60% -80% Bias (0.4%) 95% Limits of agreement (-15.7% to 16.6%) ADVIA120 vs. ADVIA % Difference Plot Mean of All 80% Identity Difference (beckman DxH 800.PLT (10E9/L) - advia120.plt (10E9/L)) / Mean of All 60% 40% 20% 0% -20% -40% -60% -80% Bias (-12.2%) 95% Limits of agreement (-29.4% to 5.1%) ADVIA120 vs. DxH % Mean of All Difference Plot 80% Identity 60% Bias (-2.1%) Difference (sysmex XT4000i.PLT (10E9/L) - advia120.plt (10E9/L)) / Mean of All 40% 20% 0% -20% -40% -60% -80% 95% Limits of agreement (-23.1% to 18.8%) ADVIA120 vs. XE4000i -100% Mean of All
35 250% Difference Plot Identity Monocytes Difference (advia 2120i MO(ass/10E3uL) - advia120.mo (ass/10e3ul)) / Mean of All 200% 150% 100% 50% 0% -50% -100% -150% -200% Bias (24.4%) 95% Limits of agreement (-30.0% to 78.9%) ADVIA120 vs. ADVIA % Mean of All 250% 200% Difference Plot Identity Difference (beckman DxH 800.MO (ass/10e3ul) - advia120.mo (ass/10e3ul)) / Mean of All 150% 100% 50% 0% -50% -100% -150% Bias (46.5%) 95% Limits of agreement (-41.9% to 134.9%) ADVIA120 vs. DxH % -250% Mean of All 250% 200% Difference Plot Identity Difference (sysmex XT4000i.MO (ass/10e3ul) - advia120.mo (ass/10e3ul)) / Mean of All 150% 100% 50% 0% -50% -100% -150% Bias (64.6%) 95% Limits of agreement (-4.3% to 133.6%) ADVIA120 vs. XE4000i -200% -250% Mean of All
36 KANG SH, KIM HK, HAM CK, LEE DS, CHO HI. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness. Int J Lab Hematol. 2008;30(6):
37 NEW PARAMETERS IN BLOOD CELL COUNTING
38 Newer parameters DxH800 XE4000i ADVIA 2120 Nucleated RBC (NRBC) Immature granulocytes (IG) ( ) Reticulocyte hemoglobin ( ) ( ) Reticulocyte volume (MRV) Immature reticulocytes (IR) Hypochromic RBC ( ) Fragmented red cells (FRC) Immature platelet fraction (IPF) Reticulocyte hemoglobin DxH800: RSF, XE4000i Ret-Hb, ADVIA2120 CHr Hypochromic RBC: DxH800: LHD, ADVIA2120 Hypochromic RBC
39 Nucleated red blood cells n Clinical significance q Disease detection q Automatic correction of WBC and lymphocyte counts n Different techniques q Signature position on the impedance size WBC histogram (DxH800) q Basophil channel and the Peroxidase channel (ADVIA) q Flow cytometry (XE-2100)
40 NRBC ADVIA
41 NRBC Beckman Coulter
42 Immature reticulocyte fraction (IRF) n Most immature reticulocytes n Clinical significance q Earliest increase of the reticulocyte fraction q Monitoring BM regeneration q Hemolysis q Therapy of iron-deficiency
43 Immature reticulocyte fraction RBC IRF LFR MFR HFR WBC/ NRBC Forwardscatter Fluorescence
44 Parameters of functional iron deficiency n CHr, hypochromic RBC (ADVIA) q Measurement: Two-angle scatter n Ret-He (Sysmex) q Reticulocyte fluorescence and FSC n MRV (mean reticulocyte volume), LHD (Low hemoglobin density), MAF (microcytic anemia factor, RSf (Red blood cell size factor), (Beckman Coulter) n Clinical utility q Predicting of iron deficiency q Manage iron supplementation therapy
45 Immature granulocytes
46 Immature granulocytes n Sysmex only n Promyelocytes, myelocytes, metamyelocytes n Clinical application?? q Detection of inflammation
47 Platelet measurement Briggs C, Harrison P, Machin SJ. Continuing developments with the automated platelet count. Int J Lab Hematol. 2007;29(2): Segal HC, Briggs C, Kunka S, et al. Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion. Br J Haematol. 2005;128(4):
48 Immunological platelet counting
49 Immature platelet fraction Briggs C, Kunka S, Hart D, Oguni S, Machin SJ. Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia. Br J Haematol. 2004;126(1):93 99.
50 Immature platelet fraction Briggs C, Kunka S, Hart D, Oguni S, Machin SJ. Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia. Br J Haematol. 2004;126(1):93 99.
51 Conclusions n Cell counters are increasingly sophisticated n The basic values are comparable n Increasing amount of new parameters q Often no internal or external QC n The complex analysis matrices of the new cell counters offer interesting options n Their clinical applications have to be evaluated
52 Automated digital imaging systems Yu H, Ok CY, Hesse A, et al. Evaluation of an automated digital imaging system, nextslide digital review network, for examination of peripheral blood smears. Arch Pathol Lab Med. 2012;136(6):
53 Automated digital imaging systems Yu H, Ok CY, Hesse A, et al. Evaluation of an automated digital imaging system, nextslide digital review network, for examination of peripheral blood smears. Arch Pathol Lab Med. 2012;136(6):
54 Is there still a role for manual blood count? Yes, there is, but qualitative, not quantitative
55 Manual vs automated: RBC Automated Manual Hemoglobin Micro-/Macrocytosis Hypo-/Hyperchromia Anisocytosis Fragmentocytes Poikilocytosis RBC inclusions Reticulocytes (Supravital stainings) Dysplasia + +++
56 Manual vs automated: WBC Automated Manual Neutrophils Basophils +++ (if neg), - (if pos) +++ Lymphocytes Eosinophils Monocytes + ++ Myeloid precursors Blasts
57 Gerber, Blood, 2011
58 Case report n A 34-year-old patient n Coombs negative hemolytic anemia with numerous spiculated RBC n Spur cell anemia q end-stage alcoholic liver disease, renal failure q accumulation of excess membrane cholesterol q impaired deformability and reduced RBC survival q Poor prognosis (median survival of a few months) n Orthotopic liver transplantation q Primary graft failure n Urgent retransplantation n 3 months follow-up: q Alcohol abstinence q Sustained improvement of the anemia and transfusion independence.
59 Gerber, Blood, 2011
60
61 Automated vs manual Automated analyzers Pro n Superior accuracy and precision n Fast n Online possibilities Manual evaluation Pro n Overview n Dysplatic changes n Long experience Con n Complexity and variation of cells remains challenging for analyzers n Acquisition costs Con n Labor-intensive n Expensive n Requires highly-trained stuff n Delayed results
Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa
Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa The Role of the FBC in clinical decision making History Examination Investigations Decision 70% FBC Laboratory
More informationBrief Communication Diagnostic Hematology
Brief Communication Diagnostic Hematology Ann Lab Med 2016;36:244-249 http://dx.doi.org/10.3343/alm.2016.36.3.244 ISSN 2234-3806 eissn 2234-3814 Establishment of Age- and Gender-Specific Reference Ranges
More informationA Look Into the Determination of Cell Morphology in Hematology in the 21 st Century. Ramon Simon-Lopez, MD Global Scientific Director Beckman Coulter
A Look Into the Determination of Cell Morphology in Hematology in the 21 st Century Ramon Simon-Lopez, MD Global Scientific Director Beckman Coulter Is cell morphology important? AML M7 CLL CD5 CD19 NHL
More informationXN-SERIES. XN Technology and Case Studies
XN Technology and Case Studies Karen Hoffman MT(ASCP) Clinical Applications Specialist OBJECTIVES Explain how scattergrams and histogram pictures can provide great insight into abnormal hematology samples
More informationPreechaya Wongkrajang, M.D., Chaicharoen Tantanate, M.D. ABSTRACT
OriginalArticle Comparison of Leukocyte Differential Count by Beckman Coulter Unicel DxH800, Beckman Coulter LH780 and Sysmex XE-5000 Preechaya Wongkrajang, M.D., Chaicharoen Tantanate, M.D. Department
More informationLavender Top Management SUCCESS BEYOND FINANCES
Lavender Top Management Alfonso Ziccardi Ass.Lab.Operation Manager for AP/CP/Safety Officer New York Hospital Medical Center of Queens SUCCESS BEYOND FINANCES 1 . VISION Mission/ Vision To successfully
More informationHematology 101. Cindy Rogers, MT(ASCP) Diagnostics System Specialist
Hematology 101 Cindy Rogers, MT(ASCP) Diagnostics System Specialist More Acronyms...» CBC» RBC» HGB» HCT» WBC» MPV» PLT» RDW» DIFF» H&H» Complete Blood Count» Red Blood Cell» Hemoglobin» Hematocrit» White
More informationCombining. and New Diagnostic. to Help Clinicians Achieve. Patient Outcomes at. per Healthcare Encounter
Combining and New Diagnostic to Help Clinicians Achieve Patient Outcomes at per Healthcare Encounter Holly McDaniel, MD hmcdaniel@clinpath.com Holly.mcdaniel@bannerhealth.com Holly McDaniel, MD AP/CP and
More informationLavender Top Management SUCCESS BEYOND FINANCES. Mission/ Vision
Lavender Top Management Alfonso Ziccardi Lab.Operation Manager for AP/CP/Safety Officer New York Hospital Medical Center of Queens SUCCESS BEYOND FINANCES Mission/ Vision. VISION To successfully develop
More informationXN-SERIES. Hematology Case Studies: Every Picture Tells a Story
Hematology Case Studies: Every Picture Tells a Story Jill Crist MT(ASCP)Field Product Specialist OBJECTIVES Explain how scattergrams and histogram pictures can provide great insight into abnormal hematology
More informationCustomer Information Literature List White Blood Cells
Customer Information Literature List White Blood Cells Date: September 2015 Subject: Literature List White Blood Cells Issued by: Scientific Customer Services Number: 150901 Note: Whether references are
More informationEvidence-Based Hematological Solutions
Evidence-Based Hematological Solutions Beyond the Routine CBC Objectives Describe novel hematology parameters and their derivation. Investigate the evidence for their clinical utility. Discuss how new
More informationClinical use of flow cytometry
Clinical use of flow cytometry Diagnosis of leukemia Combined use of intracellular staining and a cell surface marker Detection of stem cells CD34+ stem cells Monitoring of stem cell count following
More informationCustomer Information Literature List Platelets
Customer Information Literature List Platelets Date: August 2015 Subject: Literature List Platelets Issued by: Scientific Customer Services Number: 150803 Note: Whether references are given in British
More information10/30/2015. XN Case Studies: Every Picture Tells a Story
XN Case Studies: Every Picture Tells a Story Jill Crist MT(ASCP)Field Product Specialist OBJECTIVES Explain how scattergrams and histogram pictures can provide great insight into abnormal hematology samples
More information5/1/2017 DISCUSSION POINTS. Clinical Utility of Immature Cell Indices Beyond the Routine CBC John E. Donnelly BSN, RN
DISCUSSION POINTS Importance of hematological immature cell indices Clinical Utility of Immature Cell Indices Beyond the Routine CBC John E. Donnelly BSN, RN Investigate the evidence for clinical utility:
More informationCustomer Information Literature List Red Blood Cells
Customer Information Literature List Red Blood Cells Date: October 2015 Subject: Literature List Red Blood Cells Issued by: Scientific Customer Services Number: 151019 Note: Whether references are given
More informationXN series. Case interpretation. Gebruikersdag Vlaanderen- 6 oktober 2016
XN series Case interpretation Gebruikersdag Vlaanderen- 6 oktober 2016 Fluorescence flow cytometry RET channel PLT-F channel WDF channel WPC channel WNR channel Case 1 Case 1: Initial measurement Patient
More informationCELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies
CELL-DYN 3700 Strength in Technology, Proven Reliability Optical WBC Technology Patented M.A.P.S.S. Differential Multiple Technologies CELL-DYN 3700 Multiple Technologies One Superior Result Multiple Technologies
More informationPseudobasophilia in Pediatric Age Group
Original Article DOI: 10.17354/ijss/2015/259 Pseudobasophilia in Pediatric Age Group Femela Muniraj 1, Vijay Amritraj 2 1 Assistant Professor, Department of Pathology, Chettinad Hospital & Research Institute,
More informationINFECTION/ INFLAMMATION
HAEMATOLOGY OCTOBER 2017* WHITE PAPER INFECTION/ INFLAMMATION Novel haematological parameters for rapidly monitoring the immune system response Patients with inflammatory disease are common on hospital
More informationSue Jung Kim, MD, MS; Yoonjung Kim, MD; Saeam Shin, MD; Jaewoo Song, MD, MS; Jong Rak Choi, MD, PhD
Comparison Study of the Rates of Manual Peripheral Blood Smear Review From 3 Automated Hematology Analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, Using International Consensus Group Guidelines Sue
More informationApport diagnostique des nouveaux indices érythrocytaires dans l anémie
Apport diagnostique des nouveaux indices érythrocytaires dans l anémie Dr Elena Lazarova Hôpital Erasme, Université Libre de Bruxelles, CORATA Belgique 2 ème congrès de Biologie Clinique 02/10/2014 Modern
More informationDifferential Blood Smear H3
Verein für Association pour le Associazione per il medizinische Qualitätskontrolle contrôle de qualité médical controllo di qualità medico Report Differential Blood Smear H3 MQ 2015-4 MQ, Institut für
More informationEvaluation of the Abbott CELL-DYN 4000 Hematology Analyzer
Hematopathology / EVALUATION OF THE ABBOTT CELL-DYN 4 HEMATOLOGY ANALYZER Evaluation of the Abbott CELL-DYN 4 Hematology Analyzer Ernesto Grimaldi, MD, and Francesco Scopacasa, PhD Key Words: Abbott CD
More informationLEANING Away Waste and Improving Patient Care with Advances in Hematology
LEANING Away Waste and Improving Patient Care with Advances in Hematology Selke Mantie, MLS (ASCP), CLS (CSMLS), SSGBC Disclosure I am receiving an honorarium from Sysmex for today s presentation Objectives
More informationCAROL BRIGGS, DONNA GRANT, SAMUEL J. MACHIN INTRODUCTION. Department of Haematology, University College London Hospital, London, United Kingdom
ISLH Laboratory Hematology 7:75-80 2001 Carden Jennings Publishing Co., Ltd. Official Publication Comparison of the Automated Reticulocyte Counts and Immature Reticulocyte Fraction Measurements Obtained
More informationPerformance evaluation of Celltac G: a new automated hematology analyzer
Original Article Performance evaluation of Celltac G: a new automated hematology analyzer Masaaki Sugiyama 1, Tsukasa Kobayashi 1, Yuki Jisyage 2, Shigeko Yamamoto 2, Yutaka Nagai 2,3 and Hiroshi Kondo
More informationM. Velizarova, T. Yacheva and K. Tzatchev Department of Clinical Laboratory and Clinical Immunology, MU Sofia
50, 48, 2012, 3, ADVIA 2120.,.., ANALYSIS OF DIAGNOSTIC RED CELL CYTOGRAMS, GENERATED BY THE ADVIA 2120 HEMATOLOGY ANALYZER M. Velizarova, T. Yacheva and K. Tzatchev Department of Clinical Laboratory and
More informationCELL-DYN 3700 Strength in Technology, Proven Reliability
CELL-DYN 3700 Strength in Technology, Proven Reliability Optical WBC Technology Patented MAPSS Differential Multiple Technologies CELL-DYN 3700 Multiple Technologies One Superior Result Multiple Technologies
More informationGuide to the 1-3 Minute Blood Film Microscopic Review: Why and How?
Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How? Dennis B. DeNicola, DVM, PhD, DACVP Chief Veterinary Educator IDEXX Laboratories, Inc. Westbrook, ME USA Adjunct Professor of Veterinary
More informationChanges of hematological references depends on storage period and temperature conditions in rats and dogs
ISSN 1738-6055 (Print) ISSN 2233-7660 (Online) Lab Anim Res 2016: 32(4), 241-248 https://doi.org/10.5625/lar.2016.32.4.241 Changes of hematological references depends on storage period and temperature
More informationThe Egyptian Journal of Hospital Medicine (July 2017) Vol.68 (3), Page
The Egyptian Journal of Hospital Medicine (July 2017) Vol.68 (3), Page 1358-1363 Study of Automated Red Blood Cells Parameters in Correlation with Routine RBCs Morphology by Smear Review Tahany Ali El
More informationDifferential Blood Smear H3
Verein für Association pour le Associazione per il medizinische Qualitätskontrolle contrôle de qualité médical controllo di qualità medico Report Differential Blood Smear H3 MQ 2018-1 MQ, Institut für
More informationOptimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer
Optimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer Science Gene Gulati, PhD, Sean Cote, DO, Eric Behling, MD, William Kocher, MD
More informationEvaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes
Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes A. M. CENCI *1, M. MACONI *2, and B. CASOLARI *1 *1 Laboratory of
More informationScoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens
Original Article Laboratory Informatics Ann Lab Med 2015;35:341-347 http://dx.doi.org/10.3343/alm.2015.35.3.341 ISSN 2234-3806 eissn 2234-3814 Scoring System for Detecting Spurious Hemolysis in Anticoagulated
More informationDifferential Blood Smear H3
Verein für Association pour le Associazione per il medizinische Qualitätskontrolle contrôle de qualité médical controllo di qualità medico Report Differential Blood Smear H3 MQ 2014-2 MQ, Institut für
More informationThe Evolving Role of Reticulated Platelets
The Evolving Role of Kyle Riding, PhD, MLS(ASCP) CM University of Central Florida Session Objectives Platelets Recall the process involved in megakaryopoiesis and thrombocytopoiesis Explain the various
More information8/28/2015. ACP Toolbox SYSMEX CLINICAL SUPPORT TEAM SYSMEX CUSTOMER RESOURCE CENTER. Maggie Fischer BSN, RN, MS Carolyn Williams, BSN, RN, CRNI
ACP Toolbox Maggie Fischer BSN, RN, MS Carolyn Williams, BSN, RN, CRNI SYSMEX CLINICAL SUPPORT TEAM Available to provide education and resources: Tailored presentations Customer Resource Center tools Current
More informationPrecision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100
Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100 R. HERKLOTZ and A. R. HUBER Zentrum für Labormedizin, Kantonsspital Aarau, 5001 Aarau, Switzerland. The automated leukocyte(wbc)
More informationAutomated Hematology Analyzer. Differentiate with the XT-4000i
XT-4000i Automated Hematology Analyzer Differentiate with the XT-4000i Advanced Technology Solutions to Meet Your Lab s Needs Even with these challenges, the need for hematology testing has remained steady
More informationUse of the XE-2100 in a Patient with Cold Auto-immune Hemolytic Anemia
Use of the XE-21 in a Patient with Cold Auto-immune Hemolytic Anemia Gudrun STAMMINGER and Lothar BEIER Klinikum Chemnitz ggmbh, Institut für Laboratoriumsmedizin, Flemmingstraße 2, Chemnitz, Germany.
More informationof s and s Disclosure
The s of s and s Successfully implement the Advanced Clinical Parameters to benefit the patient, the lab and the Accountable Care Organization Model Disclosure Honorarium from Sysmex for this lecture 1
More information3/31/2017 OBJECTIVES CASE STUDY #1 MANUAL REVIEW. Hematology Case Studies: Every Picture Tells a Story
OBJECTIVES Hematology Case Studies: Every Picture Tells a Story Jason Anderson, MPH, MT(ASCP) Field Product Specialist Discuss how scattergram and histogram pictures can provide insight into abnormal hematology
More informationYear 2003 Paper two: Questions supplied by Tricia
QUESTION 65 A 36-year-old man presents in a post-ictal state after an observed generalised seizure. Full blood investigation shows: haemoglobin 0 g/l [128-175] mean corpuscular volume (MCV) 106 fl [80-7]
More informationHematology 101. Blanche P Alter, MD, MPH, FAAP Clinical Genetics Branch Division of Cancer Epidemiology and Genetics Bethesda, MD
Hematology 101 Blanche P Alter, MD, MPH, FAAP Clinical Genetics Branch Division of Cancer Epidemiology and Genetics Bethesda, MD Hematocrits Plasma White cells Red cells Normal, Hemorrhage, IDA, Leukemia,
More informationLaboratory for diagnosis of THALASSEMIA
SCBM343 CLINICAL PATHOLOGY 2(1-2-3) Laboratory for diagnosis of THALASSEMIA PORNTHIP CHAICHOMPOO pornthip.chh@mahidol.ac.th Acknowledgements Dr. Pranee Winichagoon Fucharoen Ms. Pornnapa Khampan Thalassemia
More informationAutoanalyzer Generated Spurious Basophilia in Adolescents and Adults
Original Article DOI: 10.17354/ijss/2015/294 Autoanalyzer Generated Spurious Basophilia in Adolescents and Adults Femela Muniraj 1, Vijay Amritraj 2, Govindaraju Soundararajan 3 1 Assistant Professor,
More informationPlease contact Customer Service with any questions. Ph: option 5
Sarasota Memorial Laboratory Services is pleased to announce that we are now performing the following testing in house: Immature Platelet Fraction (IPF) The Immature Platelet Fraction (IPF) is used to
More informationAutomated Blood Cell Counts. State of the Art. Mauro Buttarello, MD, and Mario Plebani, MD. Abstract
Hematopathology / Automated Blood Cell Counts Automated Blood Cell Counts State of the Art Mauro Buttarello, MD, and Mario Plebani, MD Key Words: Blood cell analyzers; CBC count; Leukocyte differential
More informationIt s Easier Than you Think How to Implement the Advanced Clinical Parameters
It s Easier Than you Think How to Implement the Advanced Clinical Parameters Implementation of our New Hematology Platform ( 9 HST Lines - 9 Facilities - 9 Month) Outline The Organization Banner Health
More informationCASE STUDIES PERIPHERAL BLOOD AND BODY FLUIDS
CASE STUDIES PERIPHERAL BLOOD AND BODY FLUIDS WHERE TO START anemias hemoglobinopathies new and old parameters uncommon things fluids.benign and malignant.yuk! really annoying stuff and maybe some entertainment
More informationHematopathology Case Study
Hematopathology Case Study AMP Outreach Course 2009 AMP Annual Meeting John Greg Howe Ph.D. Department of Laboratory Medicine Yale University School of Medicine November 19, 2009 HISTORY Case History An
More information9/23/2018. Hematology Case Studies Jason Anderson, MPH, MT(ASCP) Field Product Specialist OBJECTIVES FLUORESCENT FLOW CYTOMETRY
Hematology Case Studies Jason Anderson, MPH, MT(ASCP) Field Product Specialist OBJECTIVES Discuss how scattergram and histogram pictures can provide insight into abnormal hematology samples Utilize case
More informationValidation of Criteria for Smear Review Following Automated Blood Cell Analysis in Ain Shams University Laboratory
Validation of Criteria for Smear Review Following Automated Blood Cell Analysis in Ain Shams University Laboratory Azza S Eldanasoury 1, Noha H Boshnak 2, Raghda E Abd El Monem 3 1 MD, Professor of Clinical
More informationFirst comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S
111 Riv Med Lab - JLM, Vol. 4, N. 2, 2003 First comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S H. Vandeputte a, D. Darre
More informationMay is Better Sleep Month
Produced by Eastern Iowa Sleep Center A Partnership: UnityPoint-St.Luke s Mercy Medical Center Physicians Clinic of Iowa MAY 2015 VOLUME 4 ISSUE 2 Eastern Iowa Sleep Center May is Better Sleep Month Mother
More informationMyelodysplastic Syndrome Case 158
Myelodysplastic Syndrome Case 158 Dong Chen MD PhD Division of Hematopathology Mayo Clinic Clinical History 86 year old man Persistent borderline anemia and thrombocytopenia. His past medical history was
More informationRecent technological advancements in the
RATIONAL DIAGNOSTICS Novel Automated Hematology Parameters in Clinical Pediatric Practice PULKIT RASTOGI, *PRATEEK BHATIA AND NEELAM VARMA From the Departments of Hematology and *Pediatrics, PGIMER, Chandigarh,
More informationChanges in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature
Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature Gene L. Gulati, PhD; Lawrence J. Hyland, MD; William Kocher, MD;
More information3. Blood Cell Histograms:
LECTURE MODULE 6c: ELECTRONIC CELL COUNTING PART III 3. Blood Cell Histograms: a. The Coulter cell counters today provides size distributions of the cellular content: 1) volume given in µm 3 or fl vs relative
More informationSysmex Journal International Vol.9 No.2 (1999)
Sysmex Journal International Vol.9 No. (999) Evaluation and Clinical Usefulness of the Automated Hematology Analyzer, Sysmex XE- TM Kazuto TSURUDA, Tomohiro TSUJI, Tetsuya USUI, Sachiko KITAJIMA, Atsuko
More informationGetting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation.
Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation. Sysmex America White Paper One Nelson C. White Parkway,
More informationHistory. n 1865 First description of reticulocytes by Erb, who. n 1881 Using supravital staining, Ehrlich demonstrated
SYSMEX EDUCATIONAL ENHANCEMENT AND DEVELOPMENT JANUARY 2016 SEED HAEMATOLOGY The importance of reticulocyte detection Production of reticulocytes All blood cells emanate from a stem cell. Under pronounced
More informationCbc with differential
Cbc with differential Other tests might be necessary based on the results of the differential test and follow-up tests. Your doctor has many ways of determining and treating causes of abnormal blood cell
More informationDIAGNOSIS OF HEREDITARY SPHEROCYTOSIS. Elena Lazarova, MD Clinical Biology 24/09/2015
DIAGNOSIS OF HEREDITARY SPHEROCYTOSIS Elena Lazarova, MD Clinical Biology 24/09/2015 RBC MEMBRANE PROTEINS AND HEREDITARY SPHEROCYTOSIS (HS) Incidence: 1/2000-1/5000 AD inheritance (2/3); de novo mutations
More informationEvaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital
HEMATOPATHOLOGY Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital JOAN-LLUIS VIVES-CORRONS, MD, ISABEL BESSON, PHD, JOSEP MARIA JOU, MD, AND GABRIELA GUTIERREZ, MB The
More informationNEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TEST PROGRAM Glass Slide - November 2016
NEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TEST PROGRAM Glass Slide - November 2016 Results from this proficiency test event are available at: http://www.wadsworth.org/regulatory/clep/pt/summaries SLIDE
More informationContinuing Education Questions
FOCUS: INTERPRETING THE COMPLETE BLOOD COUNT Continuing Education Questions SUMMER 2017 1. A methodical approach to CBC interpretation that is aimed at medical laboratory professionals differs from one
More informationApproccio morfologico alle microangiopatie trombotiche
Approccio morfologico alle microangiopatie trombotiche Gina Zini Polo Oncologia e Ematologia Policlinico A. Gemelli Università Cattolica S. Cuore - Roma 1 Thrombotic microangiopathies Occlusive microangiopathic
More informationTaking The Fear Out of Abnormal CBC s Problems of Production, Destruction or loss
Taking The Fear Out of Abnormal CBC s Problems of Production, Destruction or loss Joanne Eddington, MN, FNP, AOCN Providence Oncology and Hematology Care Clinic - Eastside Blood Cell Abnormalities Abnormalities
More informationDR SUDHIR MEHTA MD,MNAMS,FICP. Senior Professor & Head Medical Unit SMS Medical College & Hospital Jaipur
DR SUDHIR MEHTA MD,MNAMS,FICP Senior Professor & Head Medical Unit SMS Medical College & Hospital Jaipur s.smehta@hotmail.com CBC..What is the Utility of performing this basic Hematology Test? 10/31/2010
More informationCell sorting: A bridge between morphology and flow cytometry. Pr François Mullier, Pr Bernard Chatelain July 19th, 2013
Cell sorting: A bridge between morphology and flow cytometry Pr François Mullier, Pr Bernard Chatelain July 19th, 2013 1 CELL SORTING: PRINCIPLES D.Davies CELL SORTING: PRINCIPLES Aims Efficiency Purity
More informationEvaluation of Anemia. Md. Shafiqul Bari Associate professor (Medicine) SOMC
Evaluation of Anemia Md. Shafiqul Bari Associate professor (Medicine) SOMC Definition Anemia is operationally defined as a reduction in one or more of the major RBC measurements Hemoglobin concentration
More informationInterpreting the CBC. Robert Miller PA Assistant Professor of Clinical Pediatrics and Family Medicine USC Keck School of Medicine Retired
Interpreting the CBC Robert Miller PA Assistant Professor of Clinical Pediatrics and Family Medicine USC Keck School of Medicine Retired The CBC 3 Cell Lines RBCs WBCs Platelets Assess general health Make
More informationInterpreting Hematology Scatter-Plots; One Cancer Center s Keys to Seeing the BIG Picture
Interpreting Hematology Scatter-Plots; One Cancer Center s Keys to Seeing the BIG Picture Barbara L. Burch, MHA MT (ASCP) Laboratory Manager New York University Clinical Cancer Center Disclosure Ms Burch
More informationAcute haemolysis and appearance of PNH-like clones in patients with vitamin B12 deficiency and iron deficiency after iron dextran administration
Acute haemolysis and appearance of PNH-like clones in patients with vitamin B12 deficiency and iron deficiency after iron dextran administration Chun-Liang Lin 1, Chin-Chan Lin 1,Wen-Jyi Lo 2,Yu-Chien
More informationHAEMATOLOGICAL EVALUATION OF ANEMIA. Sitalakshmi S Professor and Head Department of Clinical Pathology St John s medical College, Bangalore
HAEMATOLOGICAL EVALUATION OF ANEMIA Sitalakshmi S Professor and Head Department of Clinical Pathology St John s medical College, Bangalore Learning Objectives Laboratory tests for the evaluation of anemia
More informationDetermination of hemoglobin is one of the most commonly
ORIGINAL ARTICLE Multiple-Site Analytic Evaluation of a New Portable Analyzer, HemoCue Hb 201+, for Point-of-Care Testing Sten-Erik Bäck, PhD,* Carl G. M. Magnusson, PhD, Lena K. Norlund, MD, PhD, Henning
More information10/15/2015. Clinical Utility of Immature Cell Indices DISCUSSION POINTS HEALTHCARE REFORM PAYMENT MODEL EXPERIMENTS
Clinical Utility of Immature Cell Indices Leveraging Technology to Help Manage Anemia and Blood Utilization donnellyj@sysmex.com 2015 Sysmex America, Inc. All rights reserved. For Clinical Support Team
More informationOrdering Physician CLIENT,CLIENT. Collected REVISED REPORT
HPWET Hematopathology Consultation, MML Embed Client Hematopathology Consult REVISED INAL DIAGNOSIS Interpretation Peripheral blood, bone marrow aspirate and biopsies, bilateral iliac crests: 1. Normocellular
More informationRole of immature reticulocyte fraction in evaluation of aplastic anemia in cases of pancytopenia
Original article Role of immature reticulocyte fraction in evaluation of aplastic anemia in cases of pancytopenia Dr. R. Sindhu, S.K. Behera, D.P. Mishra Department of Pathology, MKCG medical college,
More informationNotes for the 2 nd histology lab
Notes for the 2 nd histology lab Note : Please refer to the slides and see the morphological characteristics of each cell, as the practical exam will be in the form of figures. SLIDE #2 Erythropoiesis
More informationI. Definitions. V. Evaluation A. History B. Physical Exam C. Laboratory evaluation D. Bone marrow examination E. Specialty referrals
I. Definitions II. III. Red blood cell life cycle Iron metabolism IV. Causes of anemia A. Kinetic approach 1. decreased production 2. increased destruction 3. blood loss B. Morphologic approach 1. normocytic
More informationAdvanced parameters offer faster, surer guidance to cancer care
Advanced parameters offer faster, surer guidance to cancer care captodayonline.com /advanced-parameters-offer-faster-surer-guidance-cancer-care/ Anne Paxton 9/18/2017 September 2017 After a career spent
More informationIMMATURE PLATELETS CLINICAL USE
HAEMATOLOGY FEBRUARY 2017 WHITE PAPER IMMATURE PLATELETS CLINICAL USE Differential diagnosis of thrombocytopenia Thrombocytopenia and automated platelet measurement Thrombocytopenia is a condition characterised
More informationIndication of peripheral blood smear exmination:
Indication of peripheral blood smear exmination: 1. For carried out differential WBC count. 2. For differential diagnosis of anemia. 3. For detection of parasites. 4. For diagnosis of leucemoid reaction.
More informationThe Value-Driven Laboratory. The Role of the Immature Platelet Fraction (IPF) in the Differential Diagnosis of Thrombocytopenia
The Value-Driven Laboratory The Role of the Immature Platelet Fraction (IPF) in the Differential Diagnosis of Thrombocytopenia Sysmex America White Paper 577 Aptakisic Road Lincolnshire, IL 669 USA www.sysmex.com
More informationBiological Variations of Hematologic Parameters Determined by UniCel DxH 800 Hematology Analyzer
Biological Variations of Hematologic Parameters Determined by UniCel DxH 800 Hematology Analyzer Pianhong Zhang, PhD; Huqiang Tang, MS, MPH; Keqing Chen, MS; Yingying Chen, BS; Dongsheng Xu, MD, PhD Context.
More informationHematology Unit Lab 1 Review Material
Hematology Unit Lab 1 Review Material - 2018 Objectives Laboratory instructors: 1. Assist students during lab session Students: 1. Review the introductory material 2. Study the case histories provided
More informationMorfologia normale e patologica
Morfologia normale e patologica Gina Zini Centro di Ricerca ReCAMH Dpt. Ematologia Università Cattolica S. Cuore - Roma EMATOLOGIA DI LABORATORIO: percorsi diagnostici e obiettivi clinici. Milano 11-12
More informationThe Nucleated Red Blood Cell (NRBC) Count in Thalassaemia Syndromes Paolo Danise and Giovanni Amendola
7. The Nucleated Red The Nucleated Red Blood Cell (NRBC) Count in Thalassaemia Syndromes Paolo Danise and Giovanni Amendola Introduction The purpose of this study was to evaluate the performance of the
More informationCollect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.
Complete Blood Count CPT Code: CBC with Differential: 85025 CBC without Differential: 85027 Order Code: CBC with Differential: C915 Includes: White blood cell, Red blood cell, Hematocrit, Hemoglobin, MCV,
More informationADx Bone Marrow Report. Patient Information Referring Physician Specimen Information
ADx Bone Marrow Report Patient Information Referring Physician Specimen Information Patient Name: Specimen: Bone Marrow Site: Left iliac Physician: Accession #: ID#: Reported: 08/19/2014 - CHRONIC MYELOGENOUS
More informationADVANCED HAEMATOLOGY BATTLE OF THE BANDS. Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND
ADVANCED HAEMATOLOGY BATTLE OF THE BANDS Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND The identification of immature neutrophils (bands, metamyelocytes,
More informationThe Value-Driven Laboratory. The Role of the Immature Platelet Fraction (IPF) in the Differential Diagnosis of Thrombocytopenia
The Value-Driven Laboratory The Role of the Immature Platelet Fraction (IPF) in the Differential Diagnosis of Thrombocytopenia Sysmex America White Paper 577 Aptakisic Road Lincolnshire, IL 669 USA www.sysmex.com
More informationWe noted a problem with the use of the hematology
Standard Article J Vet Intern Med 2017;31:1708 1716 Feline Differential Leukocyte Count with ProCyte Dx: Frequency and Severity of a Neutrophil-Lymphocyte Error and How to Avoid It H.W. Tvedten, V. Andersson,
More informationWHITE PAPER IMMATURE GRANULOCYTE (IG) POPULATIONS MAY IMPROVE THE ASSESSMENT OF INFECTION AND SEPSIS. Getting beyond the flags.
WHITE PAPER IMMATURE GRANULOCYTE (IG) POPULATIONS MAY IMPROVE THE ASSESSMENT OF INFECTION AND SEPSIS. Getting beyond the flags www.sysmex.com/us Introduction For many decades, physicians have relied on
More information