Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education
|
|
- Russell Cunningham
- 6 years ago
- Views:
Transcription
1 Insulin Pumps and Continuous Glucose Sensors- Embracing Technology Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education
2 Diabetes Management Tools in 1974
3 Insulin pump history First insulin pump developed by Dr. Arnold Kadish 1974 Development of the Biostator Autosyringe Inc. started to manufacture and market the first wearable pump
4 Who might be a good pump candidate? Individuals with type 1 diabetes who are struggling with glucose control Individuals with type 2 diabetes requiring insulin who struggle with glucose control Please note that Medicare does require qualifying labwork Women who are planning pregnancy or are pregnant. (some products are considered off label for pregnancy) Insulin pumps are not for everyone!
5 Benefits of Insulin Pump Therapy Improved blood glucose control -minimize fluctuations Managing the Dawn Phenomenon Fewer and less severe episodes of hypoglycemia Improvement in Hypoglycemia Unawareness Flexibility with lifestyle without losing control (variable meal times and amounts, travel, variable day to day schedule) Preventing, delaying or reversing complications of diabetes Improved blood glucose control during exercise Tighter blood glucose control prior to and during pregnancy
6 Evaluation and Considerations: Highly motivated regarding diabetes self management Currently practicing Intensive Diabetes Management. (Includes multiple daily injections, blood glucose tests 3-4 times daily documented.) Competence in or willingness to learn carbohydrate counting Physician support for pump therapy documentation of medical necessity
7 Evaluation and Considerations (cont.) Individual willingness to maintain ongoing contact with physician and other health care team members Realistic expectations of pump therapy Adequate support systems- physician and education staff experienced in pump and sensor use Adequate financial resources Physical and intellectual ability to learn how to operate the pump
8 Insulet - OmniPod OmniPod Tubeless pump Pod can be worn for 72 hours and is waterproof at 25 ft. for 60 minutes 200 unit cartridge Basal range: units/hr. with 0.05 unit increments Bolus range: units. Insulin to carb ratio In whole unit increments PDM is used for activating and programming the pod Built in blood glucose meter, list of 1000 common foods Download options: Glooko, Tidepool, Diasend. Can sync Dexcom account to Glooko account so that the sensor reports overlay
9 Insulet- OmniPod OmniPod DASH system Filed with the FDA earlier this year Bluetooth capability allowing communication with a color touchscreen PDM Higher concentration insulin pods with U500 version and U200 version ( ) Horizon Closed Loop system will bring an artificial pancreas component. (2019)
10
11
12
13 Tandem Diabetes Care T:slim X2, T:flex Rechargeable battery Color touch screen. X2 integrated with Dexcom G5 300 unit cartridge, T:flex 480 unit cartridge Basal range: units/hr. T:flex units/hr. in unit increments Bolus range: units in 0.1 unit increments T:Flex: units. I:C ratio allows fractions of grams Water tight- 3 ft for 30 minutes T:slim 2x integration with Dexcom G5 Sensor Tandem Device Updater allows software updates Download options: T-Connect, Tidepool
14 Tandem Diabetes Care Next Up? Predictive Low Glucose Suspend Filed with FDA Q Launch goal summer 2018 Will use CGM data to predict future lows and adjust insulin
15 Tandem Diabetes Care Next Up? Hybrid Closed Loop Type Zero Technologies- treat to target algorithms Dexcom G6 sensor Possible launch 2019
16
17
18
19 Medtronic Diabetes Minimed 630G System 300 unit reservoir Basal range: units/hr , 0.05 and 0.1 unit increments Bolus range: units Increments of 0.025, 0.05 and 0.1 units. Allows I:C ratios in fractions of grams Contour Next Link meter Waterproof for 12 ft. up to 24 hours SmartGuard technology Carelink Personal Software
20 Medtronic Diabetes Minimed 670G System- Hybrid Closed Loop All of the previous features Plus- Integrated with Guardian 3 Sensor Auto Mode delivery automatically adjusts basal delivery based on sensor readings, active insulin, food boluses and corrections SmartGuard Technology Carelink Personal Software
21
22
23
24
25
26
27 Points to Consider when reviewing reports Frequency of blood glucose tests per day Carbohydrate intake entered and use of the bolus calculator vs manual boluses, assess response to boluses Over-rides Frequency of infusion set changes Suspend time Average daily insulin use including basal / bolus balance Assess for patterns of hypoglycemia and hyperglycemia
28 Points to consider when reviewing reports Auto mode use Sensor wear time Basal/ bolus use Carbohydrate intake and timing of boluses Time in range Reasons for auto mode exits Response to meal boluses and corrections
29 Dexcom Dexcom G4 Platinum Available for Personal use or Professional CGM Studies Sensor duration: 7 days. 2 hour warm up time. Requires calibrations every 12 hours Transmitter battery has 6 month warranty, Receiver is rechargeable Dexcom Share2 App, Dexcom Follow App Receiver can be blinded for professional studies Management System options: Dexcom Studio, Dexcom Clarity, Glooko and Tidepool
30 Dexcom Dexcom G5 Mobile First CGM system FDA approved for making treatment decisions Sensor duration: 7 days. 2 hour warm up. Requires calibrations every 12 hours Transmitter battery: 3 month warranty Smart device compatible using Dexcom G5 Mobile App ios and Android Dexcom Clarity Reports allows sharing with clinic Management System options: Dexcom Clarity, Glooko, Tidepool.
31 Dexcom Next Up? Dexcom G6 - Approved by the FDA 3/27/18!! Expected ship- May 2018 Sensor duration: 10 days No calibration required Transmitter is lower profile No acetaminophen interference
32 Freestyle Freestyle Libre Pro System Sensor duration: 14 days No calibration required Reader is used to start the sensor, read the data and upload to Libreview
33
34
35 Freestyle Freestyle Libre (personal system) Sensor duration: 10 days Measures and stores readings every 15 minutes No calibration required No acetaminophen interference Also uses Freestyle Precision Neo test strips Available at participating pharmacies for discounted rate ( CVS, Walgreens, Walmart) Cost should be no more than approximately $65 for the reader-one time cost and $25 per sensor or $75 per month, cash pay: $79-$84 for the reader and $41-44 per sensor.
36 Freestyle Freestyle Libre Reader gives trend arrow, current glucose, 8 hr trend, daily pattern, low glucose events, time in target, visual alerts Reader can be uploaded to Libreview
37 Medtronic Guardian Connect Uses the Guardian 3 sensors and Guardian Connect Transmitter Guardian Connect App Works with the Sugar.IQ App Diabetes Assistant Displays sensor data, trends and alerts, can log events Predictive alerts Planned launch later this year
38 Medicare Coverage for CGM
39 Medicare Coverage for CGM Dexcom G5 Required Documents: Medicare CMN Assignment of Benefits Form Copies of Insurance Cards Notice of Non-coverage Form Last 2 office notes - note must state the previous Medicare requirements
40 Medicare Coverage for CGM Freestyle Libre Complete Freestyle Libre Intake Form and fax to a DME Supplier Office notes with required documentation will need to be sent For a full list of DME suppliers visit:
Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018
Diabetes Technology Update Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018 Disclosures None No future technologies are FDA approved Continuous Glucose Monitors Continuous Glucose Monitors
More informationAbbott FreeStyle Libre Pro System
, the Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationAbbott FreeStyle Libre Pro System
Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationNEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP
NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP No commercial support or sponsorship was received for this project I have nothing to disclose OBJECTIVES Identify at
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 02/13/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationOBJECTIVES THE PAST INNOVATIVE TECHNOLOGY & DIABETES DIABETES MIS MANAGEMENT IMPROVEMENTS IN DIABETES MANAGEMENT
OBJECTIVES INNOVATIVE TECHNOLOGY & DIABETES TRISHA PORRETTI, RN, BSN, CDE PWD FOR 25 YEARS Identify important safety features and differences of 3 Continuous Glucose Monitoring (CGM) systems Identify important
More information10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:
DEXCOM G5 MOBILE CGM COMPATIBLE B 100% 235 u INSULIN ON BOARD: OPTIONS 10:20 AM March 5, 2017 400 350 300 250 200 150 100 50 1.1 u 1:09 hrs BOLUS 124 mg/dl 3 HRS The pump that gets updated, not outdated.
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 05/24/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationApproved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.
Reference #: MC/L008 Page: 1 of 8 PRODUCT APPLICATION: PreferredOne Community Health Plan (PCHP) PreferredOne Administrative Services, Inc. (PAS) ERISA PreferredOne Administrative Services, Inc. (PAS)
More informationPredicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY
Predicts and helps prevent lows with * zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY Basal-IQ Technology is not a substitute for active self-management of your diabetes. Please see back cover for
More informationUpdates in Diabetes Technology
Updates in Diabetes Technology Jessica Kirk, MSN, RN, CPN, CDE Nurse Manager, Endo ECHO No disclosures Disclosures 1 Objectives Distinguish patients appropriate for continuous glucose monitoring and insulin
More informationDiabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE
Diabetes and Technology Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE Disclosure Speaker s Bureau: Janssan Pharmaceuticals Current Technology V-Go by Valeritas Continuous Sensors (personal
More informationTechnology in Diabetes Care: Emerging Level
Technology in Diabetes Care: Emerging Level Charlotte Parsons ARNP, CDE Christine Fisher, RD, CD, CDE, CPT WADE April 26, 2019 Disclosures to Participants Notice of Requirements for Successful Completion:
More informationComparative table of insulin pumps
Comparative table of insulin pumps Pumps reviewed: insight (Roche Veo 640G Mylife OmniPod Mylife S () The first stop for professional medicines advice www.sps.nhs.uk Authored May 2018 Insight OmniPod S
More informationThe Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes
The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes Sarah Dombrowski, PharmD, BCACP Pennsylvania Pharmacists Association 10/20/18 1 Objectives At the completion of this activity,
More informationReport Reference Guide
Report Reference Guide How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used to generate the sample reports was from sample patient
More informationAdvances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?
Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier? Alan B Schorr DO FAAIM FACE www.sugardoc.com abs@sugardoc.com Disclosures
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 07/10/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationDIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson
DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson March 3 rd, 2018 Who is this guy? Accelerating Progress 1 Oh that guy! Accelerating Progress 2 STATE OF T1D CARE
More informationAdvances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools
Advances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools Jennifer Trujillo, PharmD, FCCP, BCPS, CDE, BC ADM Associate Professor University of Colorado School
More informationObjectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018
Objectives Innovations in Diabetes Care and Management Barbara Walz, RN, BSN, CDE April 26, 2018 1. Briefly discuss the history of diabetes management over the past 100 years 2. Describe the impact of
More informationCOMPANY OVERVIEW. April 26, 2018
COMPANY OVERVIEW April 26, 2018 SAFE HARBOR & NON-GAAP FINANCIAL MEASURES Forward Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationCareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes
CareLink Management Software for Diabetes software REPORT REFERENCE GUIDE How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used
More informationCOMPANY OVERVIEW. July 30, 2018
COMPANY OVERVIEW July 30, 2018 SAFE HARBOR & NON-GAAP FINANCIAL MEASURES Forward Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationWith new technology available to
Insulin Pump Therapy: Who, Why, and How Alyssa Kanagaki Greenleaf, BA, MHS, PA-C With new technology available to aid patients, diabetes management in the 21st century is moving beyond metformin. Among
More informationADVANCES IN DIABETES TECHNOLOGY: A FOCUS ON CONTINUOUS GLUCOSE MONITORING 9:15 10:15 AM
ADVANCES IN DIABETES TECHNOLOGY: A FOCUS ON CONTINUOUS GLUCOSE MONITORING 9:15 10:15 AM ACPE UAN: 0107-9999-18-124-L01-P 0.1 CEU/1 hr Activity Type: Knowledge-Based Learning Objectives for Pharmacists:
More informationCONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID
FLUID Non-Discrimination Statement and Multi-Language Interpreter Services information are located at the end of this document. Coverage for services, procedures, medical devices and drugs are dependent
More informationCompany Overview February 26, 2019
Company Overview February 26, 2019 SAFE HARBOR Cautionary Note Regarding Forward-Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationDIABETES TECHNOLOGY: ENDLESS CHOICES FOR HEALTHY MANAGEMENT
DIABETES TECHNOLOGY: ENDLESS CHOICES FOR HEALTHY MANAGEMENT MAKING THE MOST OF MODERN DIABETES TREATMENTS & TECHNOLOGIES JENNIFER C. SMITH RD, LD, CDE DIRECTOR OF LIFESTYLE AND NUTRITION INTEGRATED DIABETES
More informationAdvances in Diabetes Care Technologies
1979 Advances in Diabetes Care Technologies 2015 Introduction Insulin pump use: ~ 20% - 30% of patients with T1DM < 1% of insulin-treated patients with T2DM 2007 FDA estimates ~375,000 insulin pumps for
More informationCorporate Medical Policy
Corporate Medical Policy Continuous Monitoring of Glucose in the Interstitial Fluid File Name: Origination: Last CAP Review: Next CAP Review: Last Review: continuous_monitoring_of_glucose_in_the_interstitial_fluid
More informationThe Realities of Technology in Type 1 Diabetes
The Realities of Technology in Type 1 Diabetes May 6, 2017 Rosanna Fiallo-scharer, MD Margaret Frederick, RN Disclosures I have no conflicts of interest to disclose I will discuss some unapproved treatments
More informationReport Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1
Report Reference Guide THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 How to use this guide Each type of CareLink report and its components are described in the following sections.
More informationUNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE
UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE The insulin pump Replaces injections Delivers insulin through a soft cannula
More informationBASICS OF INSULIN PUMPS. Jennifer Okemah MS RD BCADM CDE CSSD
BASICS OF INSULIN PUMPS Jennifer Okemah MS RD BCADM CDE CSSD SPEAKER DISCLOSURES: Contracted trainer for Animas, Omnipod, Medtronic Dexcom Advisory Board Sanofi Advisory Board Sanofi Contracted Speaker
More informationPATIENT TRAINING CHECKLIST MINIMED 670G SYSTEM
Technical Training Insulin Pump Infusion Set: Insulin Pump Model: BASIC FEATURES Patient has demonstrated understanding of: Button Functions Home Screen Menu review Status Screens Battery type/insertion
More informationInsulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP
Insulin Pump Therapy WakeMed Children s Endocrinology & Diabetes Overview What is an insulin pump? What are the advantages and disadvantages of an insulin pump? Lifestyle Changes Food Management Exercise
More informationNon-Invasive Glucose Monitoring. Kevin Walls April 12, :30 PM-7:30 PM.
Non-Invasive Glucose Monitoring Kevin Walls April 12, 2018 6:30 PM-7:30 PM. Technology is evolving Technology is evolving at such a rapid rate it s hard to keep up. Imagine living a healthier life without
More informationAdvances in Diabetes Care Technologies
1979 Advances in Diabetes Care Technologies 2015 Introduction Roughly 20% - 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the US FDA estimated
More informationGLOOKO DREAMED FOR ANDROID USER GUIDE
GLOOKO DREAMED FOR ANDROID USER GUIDE November 2018 IFU-0017 02 TABLE OF CONTENTS TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Glooko Intended Use... 2 Dreamed Intended Use... 2
More informationInsulin Pump An information session to help you decide if you are ready to use an insulin pump.
Insulin Pump An information session to help you decide if you are ready to use an insulin pump. Welcome Welcome to the insulin pump information session. We hope this session helps you to decide whether
More informationNDSS Helpline
Continuous GLUCOSE MONITORING A guide to using CGM for children and young people with type 1 diabetes NDSS Helpline 1300 136 588 ndss.com.au The National Diabetes Services Scheme is an initiative of the
More informationDexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer
Dexcom Current and Future Technology Innovations 2015 Jorge Valdes Chief Technical Officer G5 App Sensor (Same as G4) Indicated for adults and children down to Age 2 years Tiny insertion needle (26Ga)
More informationTHE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE
THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE Indicated for type 1 patients 14 and over. Prescription required. WARNING: Medtronic performed an evaluation of the MiniMed 670G system and determined that it
More informationDIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT
DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT Min-Jye Chen, MD Endocrinology Diabetes Management of the School-Aged Child Provided by Texas Children s Hospital Provider #18-267764-A
More informationInsulin Pumps Available in Canada
Insulin Pumps Available in Canada A Comparison from WaltzingTheDragon.ca *Accu-Chek Animas Ping/Vibe Medtronic Minimed 630G Omnipod ABOUT FORM: Is the insulin pump Tubing- Free? Is the pump? Or Water-Resistant?
More informationThe pump that gets updated, not outdated. *
FULLY FUNDED for eligible patients. The pump that gets updated, not outdated. * * Charges may apply. Dexcom CGM is not currently funded and is sold separately. Small pump. Big features. The simple-to-use
More informationInsulin Pump An information session to help you decide if you are ready to use an insulin pump.
Insulin Pump An information session to help you decide if you are ready to use an insulin pump. Welcome Welcome to the insulin pump information session. We hope this session helps you to decide whether
More informationTechnology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE
Technology for Diabetes: 101 Basic Rules of the Road Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE Quick Pump Facts! o Constant insulin supply o Pager-sized mini-computer worn
More informationTHERAPY MANAGEMENT SOFTWARE FOR DIABETES
THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2007 Medtronic MiniMed. All rights reserved. 6025274-0U2 120707 CareLink Pro Report Reference Guide 0 p.2 Sensor
More informationWelcome to CareLink Pro
Reference Guide Welcome to CareLink Pro This guide was developed to serve as a reference for obtaining patient data and reviewing CareLink Pro reports. Getting Started with CareLink Pro Adding New Patients
More information1. Continuous Glucose Monitoring
1. Continuous Glucose Monitoring 1. Physiology of interstitial fluid glucose 2. Comparison of CGM and self-monitored blood glucose (SMBG) data 3. Insulin dosing indication in BGM vs. CGM & the FDA 4. Protection
More informationCowen Investor Conference March confidently live life with ease
Cowen Investor Conference March 2018 confidently live life with ease Forward-Looking Statements This presentation contains certain forward-looking statements that involve risks and uncertainties that could
More informationContinuous Glucose Monitoring
Continuous Glucose Monitoring Information about fully-subsidised continuous glucose monitoring for children and young people with type 1 diabetes Continuous glucose monitoring (CGM) can help in managing
More informationTHERAPY MANAGEMENT SOFTWARE FOR DIABETES
THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2009 Medtronic MiniMed. All rights reserved. 6025274-012_a CareLink Pro Report Reference Guide 0 p.2 Adherence
More informationUpdate on Diabetes Technology
Update on Diabetes Technology Andrew Ahmann, MD Professor of Medicine Director, Harold Schnitzer Diabetes Health Center OHSU Objectives: Recognize the growing role of technology in assisting patients and
More informationUSING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User
USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User This is a supplemental guide. For complete instructions and safety information, please see your MiniMed 670G System
More informationUSING THE MINIMED 670G SYSTEM
USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User USING THE MINIMED 670G SYSTEM: INSTRUCTIONS FOR THE EXPERIENCED USER Checklist for starting on your MiniMed 670G
More informationContinuous Glucose Monitoring (CGM)
Continuous Glucose Monitoring (CGM) Background Info A1c Average glucose levels over previous 2-3 months Currently remains gold standard for determining control Indicator of risk for development of complications
More informationWHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE
WHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE MAY 5, 2018 OBJECTIVES Strong understanding of diabetes and its management
More informationCGM and Closing The Loop
CGM and Closing The Loop Dualities Research: Helmsely Charitable Trust, ADA, JDRF, NIDDK Consulting: Abbott Diabetes Care, Roche, Intarcia, Valeritas, Adocia, Big Foot Like With Pumps, We ve Come A Long
More information06/13/17. A. Completed a comprehensive diabetes education program within the past two years; and
Reference #: MC/L011 Page 1 of 4 PRODUCT APPLICATION: PreferredOne Community Health Plan (PCHP) PreferredOne Administrative Services, Inc. (PAS) ERISA PreferredOne Administrative Services, Inc. (PAS) Non-ERISA
More informationCOMPANY OVERVIEW. October 12, 2017
COMPANY OVERVIEW October 12, 2017 SAFE HARBOR & NON-GAAP FINANCIAL MEASURES Forward Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without
More informationCountry Health SA Local Health Network. Title: Continuous Glucose Monitoring (CGM) and Flash Glucose Monitoring (FGM) Ambulatory Service
Protocol (Clinical) Title: Continuous Glucose Monitoring (CGM) and Flash Glucose Monitoring (FGM) Ambulatory Service Protocol developed by: CHSALHN Diabetes Service Protocol Sponsor: CHSALHN, Executive
More information5/16/2018. Integrating Diabetes Technology Into your Practice : Insulin Pump Therapy. Diosclosures. What exactly is an Insulin Pump?
Integrating Diabetes Technology Into your Practice : Insulin Pump Therapy Lucia M. Novak, MSN, ANP BC, BC ADM, CDTC Director, Riverside Diabetes Center, Riverside Medical Associates Riverdale, MD Adjunct
More informationMore Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center
More Than 1 Year of Hybrid Closed Loop in Pediatrics Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center Disclosure Dr. Forlenza has served as a consultant for Abbott Diabetes Care and conducts
More informationDISCOVER THE POWER OF CONNECTION MINIMED 640G
DISCOVER THE POWER OF CONNECTION MINIMED 640G INSULIN PUMP THERAPY CHANGING LIVES TODAY Has your child just been diagnosed with insulin dependent diabetes? Or perhaps they ve been on multiple daily injection
More informationEmerging Automated Insulin Delivery Systems
Emerging Automated Insulin Delivery Systems Richard M. Bergenstal, MD International Diabetes Center Park Nicollet & HealthPartners Minneapolis, MN Presenter Name 1 Dualities: Richard M. Bergenstal, MD
More informationToday s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures
New Frontiers in Diabetes Technology Marie E. McDonnell, MD Director, Brigham and Women's Diabetes Program Division of Endocrinology, Diabetes and Hypertension Brigham and Women s Hospital Today s Goals
More informationDiabetes Technology in Irl B. Hirsch, MD University of Washington School of Medicine Seattle, WA
Diabetes Technology in 2018 Irl B. Hirsch, MD University of Washington School of Medicine Seattle, WA Dualities Research: Medtronic Diabetes Consulting: Abbott Diabetes Care, BD, Bigfoot, Roche Let s First
More informationDiabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)
Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) 9501366-011 20110401 Objectives Understand the need for insulin pumps and CGMS in managing
More informationINSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.
INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. Waterproof to a depth
More informationPumping Insulin is it for your patients?
Pumping Insulin is it for your patients? YOU CAN make managing diabetes easier. Fred Porcase D.O. Disclosures to Participants Conflicts Of Interest and Financial Relationships Disclosures: No professional
More informationINSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.
INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. MORE TIME HERE TO USING
More informationPump and Sensor Data Interpretation. Irl B. Hirsch, MD University of Washington School of Medicine
Pump and Sensor Data Interpretation Irl B. Hirsch, MD University of Washington School of Medicine Dualities Research: Medtronic Diabetes Consulting: Abbott Diabetes Care, BD, Bigfoot, Roche Raise Your
More informationWOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?
WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS? THE ONLY SYSTEM CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA MINIMED 640G SYSTEM WITH SMARTGUARD TECHNOLOGY 1 HYPOGLYCAEMIA IS CHALLENGING
More informationCARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE
CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT As part of your diabetes therapy you have
More informationRELEASED. first steps. Icon Icon name What it means
Icon Icon name What it means Connection The connection icon appears green when the Sensor feature is on and your transmitter is successfully communicating with your pump. The connection icon appears gray
More informationPROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY
PROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY Situations Requiring Special Consideration and Resource Documents Second Edition MiniMed 67G System Medical Education TABLE OF CONTENTS A PROTOCOL FOR HYBRID
More informationGlucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets
Devices Glucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets Accuracy Glucometers The ISO (International Organization for
More informationTHE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA
THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA MINIMED 640G system^ with SmartGuard technology HYPOGLYCAEMIA IS CHALLENGING FOR GLYCAEMIC CONTROL 1 AND quality of life 2 Achieving good glucose
More informationInsulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)
Insulin Pump Therapy in children Prof. Abdulmoein Al-Agha, FRCPCH(UK) aagha@kau.edu.sa Highlights Evolution of insulin pump Pumps mimics Pancreas Goals of diabetes care What lowers HbA1c Criteria for selection
More informationDiabetes Devices Workshop Angela Aldrich, PharmD, PhC April Mott, PharmD, PhC, BCPS Presbyterian Medical Group 28 January 2018
Diabetes Devices Workshop Angela Aldrich, PharmD, PhC April Mott, PharmD, PhC, BCPS Presbyterian Medical Group 28 January 2018 Pumps & Sensors & Meters, Oh My! A Tale of Two Meters Technology for glucometers
More informationMINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES
MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE OF YOUR DIABETES HAVE YOU CONSIDERED THE REAL IMPACT HYPOS HAVE ON YOUR LIFE? AN ESTIMATED 1 HOUR EVERY DAY IS LOST TO THE MANAGEMENT OF 43% OF PEOPLE
More informationGetting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite
Getting Started with Insulin Pump Therapy for the MiniMed 530G with Enlite Learning Guide PUMP Foundations MiniMed 530G Insulin Pump Settings Form: We recommend that you record all settings on this form
More informationCGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER
CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER Case 1: CGM use during pregnancy 29 yo G1P0000 at 10 5/7 weeks gestation presents to set
More informationPeople with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT
Position Statement People with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT Diabetes Australia believes that people with diabetes should have choice and access
More informationREPORT INTERPRETATION
REPORT INTERPRETATION: Interpreting ipro Professional Continuous Glucose Monitoring (CGM) Reports and Making Therapy Adjustments TARGET AUDIENCE The audience for this section is physicians, mid-level practitioners,
More informationUsing and Interpreting Diabetes Data. Irl B. Hirsch, MD University of Washington
Using and Interpreting Diabetes Data Irl B. Hirsch, MD University of Washington Dualities Research: Helmsely Charitable Trust, ADA, JDRF, NIDDK Consulting: Abbott Diabetes Care, Roche, Intarcia, Valeritas,
More informationReal-Time Continuous Glucose Monitoring: From Application to Evaluation
Real-Time Continuous Glucose Monitoring: From Application to Evaluation Gary Scheiner MS, CDE Owner/Director, Integrated Diabetes Services 333 E. Lancaster Ave., Suite 24 Wynnewood, PA 1996 (877) 735-3648
More informationDISCLAIMER: ECHO Nevada emphasizes patient privacy and asks participants to not share ANY Protected Health Information during ECHO clinics.
DISCLAIMER: Video will be taken at this clinic and potentially used in Project ECHO promotional materials. By attending this clinic, you consent to have your photo taken and allow Project ECHO to use this
More informationGLOOKO REPORT REFERENCE GUIDE
GLOOKO REPORT REFERENCE GUIDE November 2018 Version IFU-0010 02 Contents Intended Use... 2 Warnings... 2 Introduction... 3 Reports... 4 Report Criteria...4 Date Range... 4 Glucose Data Source... 4 Exercise
More informationMINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD
MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD USE AND EXAMPLES Rich Flores, RD Diabet es Clinical Manger Northern Minnesota/ St. Cloud WARNING: Territory Medtronic performed an evaluation of the MiniMed
More informationCAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION
CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION September 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC This continuing
More informationHybrid Closed Loop Status & Practical Challenges in Implementation
Hybrid Closed Loop Status & Practical Challenges in Implementation Bruce Buckingham, MD Buckingham@Stanford.edu Professor of Pediatric Endocrinology Stanford School of Medicine Conflict of Interests Company
More informationQUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?
500 1 QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3? WHAT ADDITIONAL DATA ARE NEEDED? AACE/ACE CGM Consensus Conference:
More informationFuture Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida
Future Direction of Artificial Pancreas Roy W. Beck, MD, PhD JAEB Center for Health Research Tampa, Florida Financial Disclosures Dr. Beck does not have any personal conflicts of interest His employer,
More informationReceiver and App Setup
Continuous Glucose Monitoring System Receiver and App Setup For training videos visit dexcom.com/medicare Overview Your Dexcom G5 Continuous Glucose Monitoring (CGM) System is made up of: Transmitter (Sensor
More informationASHLEY AUSTIN HEATHER MICHAELA RYAN. YOU CAN make managing diabetes easier.
ASHLEY AUSTIN HEATHER MICHAELA RYAN YOU CAN make managing diabetes easier. Overview Insulet s vision and key milestones Why the OmniPod makes CSII adherence easier while improving control The OmniPod Insulin
More informationRELEASED. Clearing your active insulin
To clear all your settings: 1. Make sure the pump is not connected to your body. 2. Go to the Manage Settings screen. Menu > Utilities > Manage Settings 3. Simultaneously press and hold and until the Manage
More information