Internal Thoracic Artery Graft Function During Exercise Assessed by Transthoracic Doppler Echography

Size: px
Start display at page:

Download "Internal Thoracic Artery Graft Function During Exercise Assessed by Transthoracic Doppler Echography"

Transcription

1 nternal Thoracic Artery Graft Function During Exercise Assessed by Transthoracic Doppler Echography Hirofumi Takemura, MD, Michio Kawasuji, MD, Naoki Sakakibara, MD, Takeo Tedoriya, MD, Teruaki Ushijima, MD, and Yoh Watanabe, MD Department of Surgery (), Kanazawa University School of Medicine, Kanazawa, Japan Background. Noninvasive quantitative assessment of internal thoracic artery (TA) graft function at rest and during exercise is important in patients who have undergone coronary artery bypass grafting. Methods. Blood flow in the TA graft was measured using transthoracic color Doppler echography before and after operation in 50 patients who underwent coronary artery grafting using an TA to the left anterior descending artery. The patients were divided into three groups according to the degree of coronary stenosis and previous anterior myocardial infarction: Group 1 included 12 patients with severe (90% or more) coronary stenosis accompanied by anterior infarction. Group 2 included 26 patients with severe coronary stenosis without anterior infarction. Group 3 included 12 patients with moderate (75% or less) coronary stenosis without anterior infarction. Transthoracic echographic images of the TA were obtained through the first intercostal space using a 7.5- MHz probe, and the diameter and cross-sectional area of the TA were measured on B-mode imaging. Systolic, diastolic, and mean blood flow velocity and volume were measured by the Doppler method. Results. nternal thoracic artery diameter increased significantly from 2.2 mm to 2.4 mm after operation. The TA flow patterns in both flow velocity and volume changed from systolic-dominant to diastolic-dominant after operation. Postoperative TA graft flow was ml/min, ml/min, and ml/min (p < 0.01, group versus 3; p < 0.05, group versus 2) and percent diastolic fraction of TA flow was 72%, 68%, and 62% (not significant) in groups 1, 2, and 3, respectively. Compared with intraoperative TA flow, which was measured using an ultrasound transit-time flowmeter, postoperative TA graft flow was increased in group 1 but not changed in group 2 or 3. The TA graft flow was measured before and after exercise in 19 patients and was compared with TA flow in 10 normal control subjects. The TA graft flow increased significantly with exercise in all patients in the three groups. Percent diastolic fraction of TA flow increased significantly with exercise in patients with severe coronary stenosis (groups 1 and 2), but decreased significantly in patients with moderate stenosis (group 3). Conclusions. Changes in native coronary artery and TA graft may be predicted by assessing TA flow pattern during exercise. Transthoracic color Doppler echography is a clinically useful noninvasive method of assessing TA graft function at rest and during exercise. (Ann Thorac Surg 1996;61:914-9) S urgical results of coronary artery bypass grafting using the internal thoracic artery (TA) have stabilized, and the use of the internal thoracic artery in coronary artery bypass grafting is associated with longterm graft patency and lower late mortality [1-3]. Thus, it is important to be able to characterize the physiologic and anatomic properties of the TA graft. Although this graft has been evaluated angiographically, its physiologic properties cannot be assessed by this technique. Seki and associates [4] described that there is a strong relationship between the TA diameter and the severity of coronary artery stenosis, and Nasu and colleagues [5] reported that the degree of left anterior descending artery stenosis affected distal TA flow using an intravascular Doppler flow guidewire. However, TA graft flow during exercise Accepted for publication Nov 25, Address reprint requests to Dr Takemura, Department of Surgery (), Kanazawa University School of Medicine, Takara-rnachi 13-1, Kanazawa, 920, Japan. cannot be assessed with these techniques because they are invasive. Noninvasive transthoracic color Doppler echography has been reported to be useful for functional evaluation of the TA graft [6]. The phenomenon that TA graft flow changes from a systolic dominant pattern preoperatively to a diastolic pattern postoperatively was reported using this technique. This study examined the physiologic properties of the TA graft and assessed the relationship of coronary stenosis to actual TA flow at rest and during exercise using transthoracic color Doppler echography. Patients and Methods The study group consisted of 50 patients who underwent elective coronary artery bypass grafting using an TA graft and additional saphenous vein grafts at Kanazawa University Medical Center. The patients ranged in age from 34 to 74 years, with a mean age of 60 years. Twenty-three of these patients had a previous history of 1996 by The Society of Thoracic Surgeons /96/$15.00 Published by Elsevier Science nc SSD (95)

2 Ann Thorac Surg TAKEMURA ET AL ;61:914-9 ECHOGRAPHC TA GRAFT FLOW A Fig 1. Preoperative internal thoracic artery blood flow pattern (A) and postoperative internal thoracic artery graft flow pattern (B) obtained from a 54-year-old man with total occlusion of the left anterior descending coronary artery. (a = peak systolic velocity; b - peak diastolic velocity.) B myocardial infarction; 12 had an anteroseptal myocardial infarction. The TA was anastomosed to the left anterior descending coronary artery in all patients. The average number of grafts per patient was 2.7. Transthoracic color Doppler echography was performed using computed sonography (Toshiba SSH-160A, Tokyo, Japan), with a 7.5-MHz linear array transducer, and two-dimensional images and pulsed Doppler signals were obtained. Patients in whom the TA graft was not visualized postoperatively were excluded from this study. The scanner head was positioned in the first intercostal space. The angle of the ultrasound beam was corrected for the velocity measurements. A left TA graft was used to bypass the left anterior descending artery in 48 patients, whereas a right TA graft was used in 2 patients. Typical flow patterns in the TA graft before and after operation are demonstrated in Figure 1. On B-mode imaging, the diameter and cross-sectional area of the TA were measured. Pulsed Doppler signals were then recorded. The following parameters were determined from the shape of the Doppler signal curve: peak systolic velocity, peak diastolic velocity, and mean velocity. Blood flow was derived from the following formula: blood flow - cross-sectional area (mm2).velocity time integral (cm) heart rate (min 1) Velocity time integral is the area between the line traced on the Doppler wave and the base line. These parameters were compared before and after operation. To evaluate the influence of the severity of coronary artery stenosis and previous anterior myocardial infarction on TA graft flow, we divided the patients into three groups. Group 1 consisted of 12 patients with greater than 75% coronary stenosis accompanied by anterior myocardial infarction. Group 2 consisted of 26 patients with greater than 75% coronary stenosis without anterior infarction. Group 3 consisted of 12 patients with 75% or less coronary stenosis without anterior infarction. nternal thoracic artery graft flows and various parameters were compared among the three groups. n 40 of the 50 patients (group 1, 8; group 2, 24; and group 3, 8), intraoperative TA graft flow was also measured after cessation of cardiopulmonary bypass, using an ultrasound transit-time blood flowmeter (model T101; Transonic Systems nc, thaca, NY). Both intraoperative and postoperative TA graft flows were compared among the three groups. Nineteen patients and 10 normal male subjects ranging in age from 24 to 30 years (mean age, 26 years) underwent a treadmill exercise test for 5 minutes on a flat surface at 5 km/h. Blood pressure and heart rate were measured, and double product was calculated before and after exercise. Two-dimensional images and pulsed Doppler signals were also obtained before and after exercise as described above. Graft flow per minute and percent diastolic fraction were determined. Twelve patients were in group 1 or 2, and the other 7 patients were in group 3. Cumulative data were expressed as the mean +_ standard deviation of the mean. Statistical analysis was performed using Student's t test or one-way analysis of variance. ntergroup differences were then compared by Fisher's protected least significant difference test. The criterion for statistical significance was p less than Results The TA diameter increased significantly from 2.2 mm to 2.4 mm postoperatively (p < 0.01) (Table 1). Although systolic flow velocity decreased significantly (p < ),

3 916 TAKEMURA ET AL Ann Thorac Surg ECHOGRAPHC TA GRAFT FLOW 1996;61:914-9 Table 1. Changes in nternal Thoracic Artery Parameters After Coronary Artery Bypass Grafting ~ Before After p Variable Operation Operation Value TA diameter 2.2 _ _ 0.4 <0.01 (mm) Systolic flow velocity _ _ 16.8 <0.001 (cm/s) Diastolic flow velocity <0.001 (cm/s) Mean flow velocity _ NS (cm/s) Total flow volume 49.9 _ _ NS Systolic flow volume 34.0 _ <0.001 Diastolic flow volume _ <0.001 Diastolic ratio (%) _ <0.001 a The TA flow changed from a systolic-dominant pattern to a diastolicdominant pattern with increases in diastolic velocity, diastolic flow, and diastolic ratio. TA = internal thoracic artery,; NS = not significant. diastolic flow velocity increased significantly (p < 0.001) postoperatively. Although total blood flow in the TA did not change, the systolic flow decreased and the diastolic flow increased significantly postoperatively. Thus postoperatively, the TA flow showed a diastolic dominant pattern. The TA blood flow was compared between the three groups (Fig 2). The TA graft flow in group 1 was higher than those in groups 2 and 3. The TA graft flow in group 2 was higher than that in group 3. Percent diastolic fraction was 72%, 68%, and 62% in groups 1, 2, and 3, respectively (Fig 3). The percentage diastolic fraction increased slightly with the severity of coronary stenosis. The TA graft flow increased postoperatively in comparison with intraoperative TA graft flow except in (%) ~ 8 7o-._u i i 20 ~ c~ 10, O- Group 1 l m Group 2 Group 3 Fig 3. Comparison of diastolic percentage of internal thoracic artery graft flow. group 3 (Fig 4). n group 1, TA graft flow increased significantly from ml/min to 95 _+ 40 ml/min. n group 2, TA graft flow increased slightly and in group 3, it decreased slightly. n groups 2 and 3, these changes did not reach statistical significance. Hemodynamic changes after exercise in normal subjects, patients with severe stenosis (groups 1 and 2), and patients with moderate stenosis (group 3) are shown in Table 2. Systolic blood pressure, heart rate, and double products increased significantly after exercise in all three groups. There were no significant differences in hemodynamic changes among the three groups. n normal subjects, TA flow increased significantly (p < 0.01), but percent diastolic fraction did not change (Table 3). The TA graft flow increased significantly in all three groups (p < for groups 1 and 2; p < 0.01 for group 3). Percent diastolic fraction of the graft flow increased (ml/rnin) i p<o.05 p<o.ol i 160 ~ l--lp< s 14 n ~ L a i,! 12 intraoperative postoperative 0 < O0 80 FKO,05 o 10 NS ~- 8 L 40 -~ 20-0 Group 1 T Group 2 Group 3 Fig 2. Comparison of internal thoracic artery (TA) graft flow obtained from transthoracic color pulsed Doppler echography. The TA graft flow in group 1 was the greatest. Group 1 Group 2 Group 3 Fig 4. Changes in internal thoracic artery (TA) graft flow from intraoperative to postoperative. Flow increased significantly in group 1 but decreased slightly in group 3.

4 Ann Thorac Surg TAKEMURA ET AL ;61:914-9 ECHOGRAPHC TA GRAFT FLOW Table 2. Changes After Exercise in Systolic Blood Pressure, Heart Rate, and Double Product Normal Control Severe Stenosis Moderate Stenosis Variable Condition (n = 10) (groups 1 and 2; n = 12) (group 3; n = 7) Systolic blood pressure (mm Hg) Heart rate (min -~) Double product (mm Hg rain ~) a-c Significance: "p ~ 0.01, b p < 0.005, c p < versus at rest. At rest 131 ± ± ± 14 After exercise 151 ± 14 c 149 ± 14 c ~ At rest 65 _ _ ± 7 After exercise 80 _+ 16 b 91 _+ 13 c 84 ± 11 ~ At rest 86 +_ ± _+ 10 After exercise 112 ± 50 ~ 134 ± 21 ~ 125 ± 12 ~ significantly in groups 1 and 2 (p ~ 0.01) but decreased significantly in group 3 (p < 0.01). Representative TA graft flow patterns before and after exercise are shown in Figure 5. The TA graft flow pattern in the patients of group 1 and 2 was diastolic-dominant at rest (see Fig 5A). After exercise, diastolic flow increased more than systolic flow (see Fig 5C). n patients in group 3, the graft flow pattern was systolic-dominant in velocity but diastolicdominant in flow volume at rest (see Fig 5B). Both systolic and diastolic velocity increased after exercise, whereas the percent diastolic fraction decreased (see Fig 5D). Comment From this study, we determined that preoperative TA flow is a three-phased pattern composed of high systolic velocity, a small negative wave, and slow diastolic velocity. This triphasic pattern is similar to that in the peripheral artery [7]. The postoperative TA flow pattern became diastolic-dominant with a significant increase in diastolic velocity and diastolic flow [8]. When we discuss the TA graft flow pattern, we must consider the fact that TA graft flows into coronary circulation in confluence with native coronary artery flow. Although some authors have reported the benefits of noninvasive color Doppler echography [6], they did not describe the relationship between the graft flow pattern and the severity of coronary stenosis. Recently, Nasu and associates [5] reported that TA graft flow with proximal coronary low-grade stenosis is lower than that with severe coronary stenosis using an intravaseular Doppler flow guidewire, which is an invasive method. Also in this study, the TA graft flow in patients with moderate coronary artery stenosis was lower than that in patients with severe stenosis, and the percent diastolic fraction in patients with moderate coronary artery stenosis was also lower than that in patients with severe stenosis. These phenomena may demonstrate that TA flow competes with native coronary artery flow in patients with moderate coronary artery stenosis. The TA is one of the branches of the subclavian artery in which mean diastolic pressure is lower than that in the aortic root from which the coronary arteries originate [9]. This may be one of the reasons for the competition between TA graft flow and native coronary artery flow in patients with moderate coronary artery stenosis. Other reasons that the postoperative TA graft does not become diastolic-dominant may include stenosis in the TA graft [10], the presence of a large branch into which most of the TA blood flows, (eg, the first intercostal branch) [11], weakness of contractility in the area affected by myocardial infarction [12], and competition with flow of the saphenous vein graft that was used for bypass near the TA graft. During observation of TA graft flow patterns, changes in flow pattern from diastolic-dominant to systolic-dominant suggest that some event has occurred in the TA graft or in the native coronary artery. Although techniques for measuring intraoperative TA graft flow and postoperative flow differ, both methods are reported to be reliable [12, 13]. This study demonstrated that flow in the TA graft increased postoperatively, especially in group 1. The TA graft flow decreased slightly in group 3 in comparison with intraoperative TA graft flow. There were 4 patients in group 1 in whom the intraoperative TA graft flow into the infarcted area was very low (less than 15 ml/min), indicating the doubtful viability of that area. However, the fact that these very Table 3. Changes After Exercise in nternal Thoracic Artery Flow and Percent Diastolic Fraction in Normal Subjects and Patients With Coronary Stenosis Variable TA flow (ml[min) Percent diastolic fraction (%) Condition Severe Stenosis Moderate Stenosis Normal Subjects (groups 1 and 2; (group 3; (n = 10) n = 12) n = 7) At rest 56 ± After exercise 86 ± 28 a 91 _+ 50 b 66 ± 42 a At rest 31.5 _ ± ± 10.5 After exercise 31.7 ± a ~' a,b Significance: a p ~ 0.01, b p < versus at rest. TA = internal thoracic artery.

5 918 TAKEMURA ET AL Ann Thorac Surg ECHOGRAPHC TA GRAFT FLOW 1996;61: O.1H A C B D Fig 5. Representative pulsed Doppler images at rest and after exercise. (A, C) A patient with total occlusion of the left anterior descending artery (group 2). (B, D) A patient with 75% coronary stenosis (group 3). (A, B) Before exercise. (C, D) After exercise. low intraoperative TA flows increased postoperatively shows some relation to the improvement in circulation and metabolism in the myocardium, so-called hibernation [141, whereas the fact that TA graft flow decreased in group 3 indicates that competitive flow might result in reduced TA flow and string sign, or in extreme cases a no-flow situation, as reported by Aris and co-workers [15] and Dincer and Barner [16]. Van Citters and Franklin [17] reported that coronary blood flow in the dog increased fourfold with exercise. Hongo and associates [18] demonstrated that coronary blood flow increased from 155 ml/min to 285 ml/min by atrial-pacing-induced tachycardia and that the increase in coronary artery flow with exercise depends on an increase in diastolic flow although diastolic duration is decreased. n this study, TA graft flow increased significantly in all patients with exercise, but the increase in TA graft flow in patients with severe coronary stenosis

6 Ann Thorac Surg TAKEMURA ET AL ;61:914-9 ECHOGRAPHC TA GRAFT FLOW was greater than that in patients with moderate stenosis. Although the percent diastolic fraction increased significantly in patients with severe coronary artery stenosis, it decreased significantly in patients with moderate coronary stenosis. As Kajiya and colleagues [19] demonstrated that velocity waveform in a native coronary artery beyond a vein bypass changes to a systolic-predominant pattern in a patient with severe stenosis during transit graft occlusion, coronary flow depends mostly on TA graft flow in such a patient. Otherwise, as described above, the TA graft flow competes with native coronary artery flow in patients with moderate coronary stenosis. Under such conditions, diastolic flow in native coronary artery exceeds that in TA graft after exercise. Because Nasu and associates [5] demonstrated that progression of left anterior descending coronary artery disease changed the TA graft flow pattern measured by intravascular Doppler flow guidewire, when our noninvasive examination revealed a change in TA graft flow pattern during exercise, we were able to predict the progression of the native coronary artery disease. Further follow-up and study are necessary to confirm these findings. Transthoracic color Doppler echography allows accurate assessment of the TA. t can be performed postoperatively for clinical follow-up and for studies of cardiac physiology and pharmacology repeatedly and noninvasively. t provides considerable information concerning the TA graft, which is key to the patient's prognosis. References 1. Boylan MJ, Lytle BW, Loop FD, et al. Surgical treatment of isolated left anterior descending coronary stenosis. Comparison of left internal mammary artery and venous autograft at 18 to 20 years of follow-up. J Thorac Cardiovasc Surg 1994;107: Loop FD, Lytle BW, Cosgrove DM, et al. nfluence of the internal-mammary-artery graft on 10-year survival and other cardiac events. N Engl J Med 1986;314: Cameron A, Davis KB, Green GE, Myers WO, Pettinger M. Clinical implications of internal mammary artery bypass grafts. The coronary artery surgery study experience. Circulation 1988;77: Seki T, Kitamura S, Kawachi K, et al. A quantitative study of postoperative luminal narrowing of the internal thoracic artery graft in coronary artery bypass surgery. J Thorac Cardiovasc Surg 1992;104: Nasu M, Akasaka T, Okazaki T, et al. Postoperative flow characteristics of left internal thoracic artery grafts. Ann Thorac Surg 1995;59: De Bono DP, Samani NJ, Spyt TJ, Hartshorne T, Thrush AJ, Evans DH. Transcutaneous ultrasound measurement of blood-flow in internal mammary artery to coronary artery grafts. Lancet 1992;339: Jager KA, Phillips DJ, Martin RL, et al. Noninvasive mapping of lower limb arterial lesions. Ultrasound Med Biol 1985;11: Fusejima K, Takahara Y, Sudo Y, Murayama H, Masuda Y, nagaki Y. Comparison of coronary hemodynamics in patients with internal mammary artery and saphenous vein coronary artery bypass grafts. A noninvasive approach using combined two-dimensional and Doppler echocardiography. J Am Coil Cardiol 1990;15: Tedoriya T, Kawasuji M, Ueyama K, Sakakibara N, Takemura H, Watanabe Y. Physiologic characteristics of coronary artery bypass grafts. Ann Thorac Surg 1993;56: Van Son JAM, Skotnicki SH, Peters MBM, Pijls NH, Noyez L, van Asten WNJC. Noninvasive hemodynamic assessment of the internal mammary artery in myocardial revascularization. Ann Thorac Surg 1993;55: Singh RN, Magovern GJ. nternal mammary graft. mproved flow resulting from correction of steal phenomenon. J Thorac Cardiovasc Surg 1982;84: Olinger GN, Mulder DG, Maloney ]V Jr, Buckberg GD. Phasic coronary flow. ntraoperative evaluation of flow distribution, myocardial function, and reactive hyperemic response. Ann Thorac Surg 1976;21: Barnes RJ, Comline RS, Dobson A, Drost CJ. An implantable transit time ultrasonic blood flow meter. J Physiol 1983;345: Braunwald E, Rutherford JD. Reversible ischemic left ventricular dysfunction. Evidence for the "hibernating myocardium." J Am Coil Cardiol 1986;8: Aris A, Borrhs X, Rami6 J. Patency of internal mammary artery grafts in no-flow situations. J Thorac Cardiovasc Surg 1987;93: Dincer B, Barner HB. The "occluded" internal mammary artery graft. Restoration of patency after apparent occlusion associated with progression of coronary disease. J Thorac Cardiovasc Surg 1983;85: Van Citters RL, Franklin DL. Cardiovascular performance of Alaska sled dogs during exercise. Circ Res 1969;24: Hongo M, Nakatsuka T, Watanabe N, et al. Effects of heart rate on phasic coronary blood flow pattern and flow reserve in patients with normal coronary arteries. A study with an intravascular Doppler catheter and spectral analysis. Am Heart J 1994;127: Kajiya F, Tsujioka K, Ogasawara Y, et al. Analysis of flow characteristics in poststenotic region of the human coronary artery during bypass graft surgery. Circulation 1987;76:

T having a superior rate of long-term patency and is

T having a superior rate of long-term patency and is Physiologic Characteristics of Coronary Artery Bypass Grafts Takeo Tedoriya, MD, Michio Kawasuji, MD, Keishi Ueyama, MD, Naoki Sakakibara, MD, Hirofumi Takemura, MD, and Yoh Watanabe, MD Department of

More information

Postoperative flow capacity of the left internal thoracic

Postoperative flow capacity of the left internal thoracic CORONARY FLOW RESERVE EARLY AND LATE AFTER MINIMALLY INVASIVE CORONARY ARTERY BYPASS GRAFTING IN PATIENTS WITH TOTALLY OCCLUDED LEFT ANTERIOR DESCENDING CORONARY ARTERY Ruggero De Paulis, MD Fabrizio Tomai,

More information

Received 20 January 2008; received in revised form 30 June 2008; accepted 11 July 2008; Available online 23 August 2008

Received 20 January 2008; received in revised form 30 June 2008; accepted 11 July 2008; Available online 23 August 2008 European Journal of Cardio-thoracic Surgery 34 (2008) 833 838 www.elsevier.com/locate/ejcts Patency rate of the internal thoracic artery to the left anterior descending artery bypass is reduced by competitive

More information

Mandatory knowledge about natural history of coronary grafts. P.Sergeant P. Maureira K.U.Leuven, Belgium

Mandatory knowledge about natural history of coronary grafts. P.Sergeant P. Maureira K.U.Leuven, Belgium Mandatory knowledge about natural history of coronary grafts P.Sergeant P. Maureira K.U.Leuven, Belgium Types of grafts Arterial ITA/IMA (internal thoracic/mammary artery) Radial artery Gastro-epiploïc

More information

Postoperative Flow Characteristics of Left Internal Thoracic Artery Grafts

Postoperative Flow Characteristics of Left Internal Thoracic Artery Grafts Postoperative Flow Characteristics of Left nternal Thoracic rtery Grafts Michihiro Nasu, MD, Takashi kasaka, MD, Tsuyoshi Okazaki, MD, Masahiko Shinkai, MD, Hiroshi Fujiwara, MD, Jun Sono, MD, Yukikatsu

More information

Changing profile of patients undergoing redo-coronary artery surgery q

Changing profile of patients undergoing redo-coronary artery surgery q European Journal of Cardio-thoracic Surgery 21 (2002) 205 211 www.elsevier.com/locate/ejcts Changing profile of patients undergoing redo-coronary artery surgery q Frans M. van Eck, Luc Noyez*, Freek W.A.

More information

Management during Reoperation of Aortocoronary Saphenous Vein Grafts with Minimal Atherosclerosis by Angiography

Management during Reoperation of Aortocoronary Saphenous Vein Grafts with Minimal Atherosclerosis by Angiography Management during Reoperation of ortocoronary Saphenous Vein Grafts with therosclerosis by ngiography William G. Marshall, Jr., M.D., Jeffrey Saffitz, M.D., and Nicholas T. Kouchoukos, M.D. STRCT The proper

More information

Importance of the third arterial graft in multiple arterial grafting strategies

Importance of the third arterial graft in multiple arterial grafting strategies Research Highlight Importance of the third arterial graft in multiple arterial grafting strategies David Glineur Department of Cardiovascular Surgery, Cliniques St Luc, Bouge and the Department of Cardiovascular

More information

ASDIN 7th Annual Scientific Meeting DISCLOSURES TECHNICAL CONSIDERATIONS TECHNICAL CONSIDERATIONS UTILITY OF ULTRASOUND IN EVALUATING ACCESS

ASDIN 7th Annual Scientific Meeting DISCLOSURES TECHNICAL CONSIDERATIONS TECHNICAL CONSIDERATIONS UTILITY OF ULTRASOUND IN EVALUATING ACCESS DISCLOSURES UTILITY OF ULTRASOUND IN EVALUATING ACCESS DYSFUNCTION None Vandana Dua Niyyar, MD Assistant Professor of Medicine, Division of Nephrology, Emory University UTILITY OF ULTRASOUND IN ACCESS

More information

Non-invasive examination

Non-invasive examination Non-invasive examination Segmental pressure and Ankle-Brachial Index (ABI) The segmental blood pressure (SBP) examination is a simple, noninvasive method for diagnosing and localizing arterial disease.

More information

CPT Code Details

CPT Code Details CPT Code 93572 Details Code Descriptor Intravascular Doppler velocity and/or pressure derived coronary flow reserve measurement (coronary vessel or graft) during coronary angiography including pharmacologically

More information

CHANGING FLOW PATTERN OF THE INTERNAL THORACIC ARTERY UNDERGOING CORONARY BYPASS GRAFTING: CONTINUOUS-WAVE DOPPLER ASSESSMENT

CHANGING FLOW PATTERN OF THE INTERNAL THORACIC ARTERY UNDERGOING CORONARY BYPASS GRAFTING: CONTINUOUS-WAVE DOPPLER ASSESSMENT CHANGING FLOW PATTERN OF THE INTERNAL THORACIC ARTERY UNDERGOING CORONARY BYPASS GRAFTING: CONTINUOUS-WAVE DOPPLER ASSESSMENT Raymond Cartier, MD Omar Semper Dias, MD Michel Pellerin, MD Yves H6bert, MD

More information

T the ST segment during attacks caused by coronary

T the ST segment during attacks caused by coronary Different Responses of Coronary Artery and Internal Mammary Artery Bypass Grafts to Ergonovine and Nitroglycerin in Variant Angina Soichiro Kitamura, MD, Ryuichi Morita, MD, Kanji Kawachi, MD, Sogo Iioka,

More information

Cigna - Prior Authorization Procedure List Cardiology

Cigna - Prior Authorization Procedure List Cardiology Cigna - Prior Authorization Procedure List Cardiology Category CPT Code CPT Code Description 33206 Insertion of new or replacement of permanent pacemaker with transvenous electrode(s); atrial 33207 Insertion

More information

Angiographic 5-Year Follow-up Study of Right Gastroepiploic Artery Grafts

Angiographic 5-Year Follow-up Study of Right Gastroepiploic Artery Grafts Angiographic 5-Year Follow-up Study of Right Gastroepiploic Artery Grafts Sari Voutilainen, MD, Kalervo Verkkala, MD, PhD, Antero J~irvinen, MD, PhD, and Pekka Keto, MD, PhD Departments of Thoracic and

More information

Coronary atherosclerotic heart disease remains the number

Coronary atherosclerotic heart disease remains the number Twenty-Year Survival After Coronary Artery Surgery An Institutional Perspective From Emory University William S. Weintraub, MD; Stephen D. Clements, Jr, MD; L. Van-Thomas Crisco, MD; Robert A. Guyton,

More information

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program: UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program: Electrophysiology Implant Code Classification Table The

More information

No-reflow Phenomenon in Patients with Acute Myocardial Infarction: Its Pathophysiology and Clinical Implications

No-reflow Phenomenon in Patients with Acute Myocardial Infarction: Its Pathophysiology and Clinical Implications No-reflow Phenomenon in Patients with Acute Myocardial Infarction: Its Pathophysiology and Clinical Implications * 164 Ito Acta Med. Okayama Vol. 63, No. 4 Normal case Anterior MI Fig. 3 Myocardial contrast

More information

I internal mammary artery (IMA) is widely accepted as

I internal mammary artery (IMA) is widely accepted as Routine Use of the Left Internal Mammary Artery Graft in the Elderly Timothy J. Gardner, MD, Peter S. Greene, MD, Mary F. Rykiel, RN, William A. Baumgartner, MD, Duke E. Cameron, MD, Alfred S. Casale,

More information

Lower Extremity Arterial Doppler

Lower Extremity Arterial Doppler Lower Extremity Arterial Doppler 1. Spectral Doppler waveform should be taken in distal aorta and common iliac arteries. 2. R/L common femoral artery (CFA) color Doppler with velocity and B-mode. 3. R/L

More information

evicore cardiology procedures and services requiring prior authorization

evicore cardiology procedures and services requiring prior authorization evicore cardiology procedures and services requiring prior authorization Moda Health Commercial Group and Individual Members* *Check EBT to verify member enrollment in evicore program Radiology Advanced

More information

T has been prevailing in coronary bypass surgery due. Exercise Coronary Flow Reserve of Bilateral Internal Thoracic Artery Bypass Grafts

T has been prevailing in coronary bypass surgery due. Exercise Coronary Flow Reserve of Bilateral Internal Thoracic Artery Bypass Grafts Exercise Coronary Flow Reserve of Bilateral nternal Thoracic Artery Bypass Grafts Ryuichi Morita, MD, Soichiro Kitamura, MD, Kanji Kawachi, MD, Tetsuji Kawata, MD, Kazumi Mizuguchi, MD, Yoichi Kameda,

More information

Codes Requiring Authorization from MedSolutions (MSI): Updated 3/2014

Codes Requiring Authorization from MedSolutions (MSI): Updated 3/2014 s Requiring Authorization from MedSolutions (): Updated 3/2014 0042T Cerebral Perfusion Analysis using CT with contrast 0159T CAD, including computer algorithm analysis, BREAST MRI 0195T prepare interspace,

More information

Postoperative AV Fistula Evaluation. Postoperative examination protocol. Postoperative AVF Protocol. Hemodialysis Access Surveillance

Postoperative AV Fistula Evaluation. Postoperative examination protocol. Postoperative AVF Protocol. Hemodialysis Access Surveillance Hemodialysis Access Surveillance Postoperative AV Fistula Evaluation Failure of maturation Stenosis Perigraft mass/fluid collection Joseph L. Mills, Sr., M.D. Professor of Surgery Chief, Division of Vascular

More information

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep Ultrasound Basic Echocardiography for the Internist Carol Gruver, MD, FACC UT Erlanger Cardiology Mechanical wave of compression and rarefaction Requires a medium for transmission Ultrasound frequency

More information

Competitive Blood Flow in the- Coronary Circulation Simulating Progression of Proximal Coronary Artery Disease After Saphenous Vein Bypass Surgery*

Competitive Blood Flow in the- Coronary Circulation Simulating Progression of Proximal Coronary Artery Disease After Saphenous Vein Bypass Surgery* Clin. Cardiol. 7, 179-183 (1984) @ Clinical Cardiology Publishing Co., Inc. Competitive Blood Flow in the- Coronary Circulation Simulating Progression of Proximal Coronary Artery Disease After Saphenous

More information

Left Subclavian Artery Stenosis in Coronary Artery Bypass: Prevalence and Revascularization Strategies

Left Subclavian Artery Stenosis in Coronary Artery Bypass: Prevalence and Revascularization Strategies Left Subclavian Artery Stenosis in Coronary Artery Bypass: Prevalence and Revascularization Strategies Ho Young Hwang, MD, Jin Hyun Kim, MD, Whal Lee, MD, PhD, Jae Hyung Park, MD, PhD, and Ki-Bong Kim,

More information

Journal of the American College of Cardiology Vol. 45, No. 3, by the American College of Cardiology Foundation ISSN /05/$30.

Journal of the American College of Cardiology Vol. 45, No. 3, by the American College of Cardiology Foundation ISSN /05/$30. Journal of the American College of Cardiology Vol. 45, No. 3, 2005 2005 by the American College of Cardiology Foundation ISSN 0735-1097/05/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2004.09.072

More information

Analysis of Mortality Within the First Six Months After Coronary Reoperation

Analysis of Mortality Within the First Six Months After Coronary Reoperation Analysis of Mortality Within the First Six Months After Coronary Reoperation Frans M. van Eck, MD, Luc Noyez, MD, PhD, Freek W. A. Verheugt, MD, PhD, and Rene M. H. J. Brouwer, MD, PhD Departments of Thoracic

More information

Physician s Vascular Interpretation Examination Content Outline

Physician s Vascular Interpretation Examination Content Outline Physician s Vascular Interpretation Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 6 Cerebrovascular Abdominal Peripheral Arterial - Duplex Imaging Peripheral Arterial

More information

Long-term patency of as well as patient survival associated

Long-term patency of as well as patient survival associated Angiographic Predictors of Graft Patency and Disease Progression After Coronary Artery Bypass Grafting With Arterial and Venous Grafts Hannu I. Manninen, MD, PhD, Pekka Jaakkola, MD, Matti Suhonen, MD,

More information

Aortic Valve Replacement or Heart Transplantation in Patients With Aortic Stenosis and Severe Left Ventricular Dysfunction

Aortic Valve Replacement or Heart Transplantation in Patients With Aortic Stenosis and Severe Left Ventricular Dysfunction Aortic Valve Replacement or Heart Transplantation in Patients With Aortic Stenosis and Severe Left Ventricular Dysfunction L.S.C. Czer, S. Goland, H.J. Soukiasian, S. Gallagher, M.A. De Robertis, J. Mirocha,

More information

Distal Coronary Artery Dissection Following Percutaneous Transluminal Coronary Angioplasty

Distal Coronary Artery Dissection Following Percutaneous Transluminal Coronary Angioplasty Distal Coronary rtery Dissection Following Percutaneous Transluminal Coronary ngioplasty Douglas. Murphy, M.D., Joseph M. Craver, M.D., and Spencer. King 111, M.D. STRCT The most common cause of acute

More information

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING STANDARD - Primary Instrumentation 1.1 Cardiac Ultrasound Systems SECTION 1 Instrumentation Ultrasound instruments

More information

Rotation: Echocardiography: Transthoracic Echocardiography (TTE)

Rotation: Echocardiography: Transthoracic Echocardiography (TTE) Rotation: Echocardiography: Transthoracic Echocardiography (TTE) Rotation Format and Responsibilities: Fellows rotate in the echocardiography laboratory in each clinical year. Rotations during the first

More information

Complete Proximal Occlusion of All Three Main Coronary Arteries Complicated With a Left Main Coronary Aneurysm: A Case Report

Complete Proximal Occlusion of All Three Main Coronary Arteries Complicated With a Left Main Coronary Aneurysm: A Case Report J Cardiol 2004 Nov; 44 5 : 201 205 Complete Proximal Occlusion of All Three Main Coronary Arteries Complicated With a Left Main Coronary Aneurysm: A Case Report Takatoshi Hiroshi Akira Takahiro Masayasu

More information

Saphenous Vein Autograft Replacement

Saphenous Vein Autograft Replacement Saphenous Vein Autograft Replacement of Severe Segmental Coronary Artery Occlusion Operative Technique Rene G. Favaloro, M.D. D irect operation on the coronary artery has been performed in 180 patients

More information

Improved long-term survival has been demonstrated by

Improved long-term survival has been demonstrated by Benefit of Bilateral Over Single Internal Mammary Artery Grafts for Multiple Coronary Artery Bypass Grafting Masahiro Endo, MD; Hiroshi Nishida, MD; Yasuko Tomizawa, MD; Hiroshi Kasanuki, MD Background

More information

Prior Authorization for Non-emergency Cardiac Imaging Procedures

Prior Authorization for Non-emergency Cardiac Imaging Procedures Attention: All Providers Prior Authorization for Non-emergency Cardiac Imaging Procedures The N.C. Medicaid Program is considering implementation of a prior authorization (PA) program for non-emergency

More information

Results of Reoperation

Results of Reoperation Results of Reoperation for Recurrent Angina Pectoris William I. Norwood, M.D., Lawrence H. Cohn, M.D., and John J. Collins, Jr., M.D. ABSTRACT Although a coronary bypass operation improves the quality

More information

Indications: following: embolization. artery that has diseases 5. The evaluation. of suspected. such entities. a cold hand. biopsy

Indications: following: embolization. artery that has diseases 5. The evaluation. of suspected. such entities. a cold hand. biopsy Peripheral Arterial Ultrasound Protocol Using Color and Spectral Doppler Reviewed by: Mark Yuhasz, MD Last Review Date: January 2015 Contact: (866) 761 4200, Option 1 Indications: The indications for peripheral

More information

Outline. EuroScore II. Society of Thoracic Surgeons Score. EuroScore II

Outline. EuroScore II. Society of Thoracic Surgeons Score. EuroScore II SURGICAL RISK IN VALVULAR HEART DISEASE: WHAT 2D AND 3D ECHO CAN TELL YOU AND WHAT THEY CAN'T Ernesto E Salcedo, MD Professor of Medicine University of Colorado School of Medicine Director of Echocardiography

More information

Ventricular Function and the Native Coronary Circulation Five Years after Myocardial Revascularhation

Ventricular Function and the Native Coronary Circulation Five Years after Myocardial Revascularhation Ventricular Function and the Native Coronary Circulation Five Years after Myocardial Revascularhation Denis H. Tyras, M.D., Naseer Ahmad, M.D., George C. Kaiser, M.D., Hendrick B. Barner, M.D., John E.

More information

On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft in the process of CABG

On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft in the process of CABG DOI 10.1186/s12938-016-0260-4 BioMedical Engineering OnLine RESEARCH Open Access On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft

More information

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Appendix II: ECHOCARDIOGRAPHY ANALYSIS Appendix II: ECHOCARDIOGRAPHY ANALYSIS Two-Dimensional (2D) imaging was performed using the Vivid 7 Advantage cardiovascular ultrasound system (GE Medical Systems, Milwaukee) with a frame rate of 400 frames

More information

Carlos Eduardo Suaide Silva, Luiz Darcy Cortez Ferreira, Luciana Braz Peixoto, Claudia Gianini Monaco, Manuel Adán Gil, Juarez Ortiz

Carlos Eduardo Suaide Silva, Luiz Darcy Cortez Ferreira, Luciana Braz Peixoto, Claudia Gianini Monaco, Manuel Adán Gil, Juarez Ortiz Silva et al Original Article Arq Bras Cardiol Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography. A New Alternative in the Assessment of the Segmental

More information

Prof. Nabil CHAKFE et coll.

Prof. Nabil CHAKFE et coll. Prof. Nabil CHAKFE et coll. For the Department of Vascular Surgery and Kidney Transplantation University Hospital of Strasbourg, FRANCE Popliteal artery entrapment: misdiagnosed Epidemiology Prevalence:

More information

Pearls & Pitfalls in nuclear cardiology

Pearls & Pitfalls in nuclear cardiology Pearls & Pitfalls in nuclear cardiology Maythinee Chantadisai, MD., NM physician Division of Nuclear Medicine, Department of radiology, KCMH Principle of myocardial perfusion imaging (MPI) Radiotracer

More information

DESCRIPTION: Percentage of patients aged 18 years and older undergoing isolated CABG surgery who received an IMA graft

DESCRIPTION: Percentage of patients aged 18 years and older undergoing isolated CABG surgery who received an IMA graft Measure #43 (NQF 0134): Coronary Artery Bypass Graft (CABG): Use of Internal Mammary Artery (IMA) in Patients with Isolated CABG Surgery National Quality Strategy Domain: Effective Clinical Care 2017 OPTIONS

More information

Choice of Hemodynamic Support During Coronary Artery Bypass Surgery for Prevention of Stroke

Choice of Hemodynamic Support During Coronary Artery Bypass Surgery for Prevention of Stroke The Journal of The American Society of Extra-Corporeal Technology Choice of Hemodynamic Support During Coronary Artery Bypass Surgery for Prevention of Stroke Yasuyuki Shimada, MD, PhD;* Hitoshi Yaku,

More information

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program: Notification and Prior Authorization Program: Electrophysiology Implant Classification Table The following chart contains the codes that require notification or prior authorization as part of UnitedHealthcare

More information

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012 Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012 Page 1 Table of Contents Carotid Anatomy Carotid Duplex

More information

Adaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand

Adaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand 336 Department of Cardiology, Mont-Godinne Hospital, Université Catholique de Louvain, 5530 Yvoir, Belgium O Gurné P Chenu B Marchandise E Rombaut D Blommaert E Schroeder Department of Cardiovascular and

More information

Diagnosis of Middle Cerebral Artery Occlusion with Transcranial Color-Coded Real-Time Sonography

Diagnosis of Middle Cerebral Artery Occlusion with Transcranial Color-Coded Real-Time Sonography Diagnosis of Middle Cerebral Artery Occlusion with Transcranial Color-Coded Real-Time Sonography Kazumi Kimura, Yoichiro Hashimoto, Teruyuki Hirano, Makoto Uchino, and Masayuki Ando PURPOSE: To determine

More information

HD Scanning: Velocities and Volume Flow

HD Scanning: Velocities and Volume Flow HD Scanning: Velocities and Volume Flow Non-Invasive Lab Symposium West Orange, NJ April 27, 2018 Volume Flow Cindy Sturt, MD, FACS, RVT 500,000 Americans on dialysis 20-25% annual mortality 65% 5 year

More information

Recommendations for Follow-up After Vascular Surgery Arterial Procedures SVS Practice Guidelines

Recommendations for Follow-up After Vascular Surgery Arterial Procedures SVS Practice Guidelines Recommendations for Follow-up After Vascular Surgery Arterial Procedures 2018 SVS Practice Guidelines vsweb.org/svsguidelines About the guidelines Published in the July 2018 issue of Journal of Vascular

More information

Shock, Monitoring Invasive Vs. Non Invasive

Shock, Monitoring Invasive Vs. Non Invasive Shock, Monitoring Invasive Vs. Non Invasive Paula Ferrada MD Assistant Professor Trauma, Critical Care and Emergency Surgery Virginia Commonwealth University Shock Fluid Pressors Ionotrope Intervention

More information

Intraoperative Imaging and TTFM

Intraoperative Imaging and TTFM Intraoperative Imaging and TTFM Use intraoperative ultrasound imaging and The MiraQ Cardiac combines ultrasound cardiac surgery. There is growing support of the idea that checking grafts and anastomoses

More information

Adult Echocardiography Examination Content Outline

Adult Echocardiography Examination Content Outline Adult Echocardiography Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 Anatomy and Physiology Pathology Clinical Care and Safety Measurement Techniques, Maneuvers,

More information

Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement?

Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement? Original Article Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement? Hiroaki Sakamoto, MD, PhD, and Yasunori Watanabe, MD, PhD Background: Recently, some articles

More information

The use of both the left and right internal thoracic arteries (ITAs) for revascularization

The use of both the left and right internal thoracic arteries (ITAs) for revascularization Angiographic evidence for reduced graft patency due to competitive flow in composite arterial T-grafts Dmitry Pevni, MD, a Itzhak Hertz, MD, b Benjamin Medalion, MD, c Amir Kramer, MD, a Yosef Paz, MD,

More information

Management of In-stent Restenosis after Lower Extremity Endovascular Procedures

Management of In-stent Restenosis after Lower Extremity Endovascular Procedures Management of In-stent Restenosis after Lower Extremity Endovascular Procedures Piotr Sobieszczyk, MD Associate Director, Cardiac Catheterization Laboratory Cardiovascular Division and Vascular Medicine

More information

Detection Of Functional Significance of Coronary Stenoses Using Dynamic. Values Of Myocardial Blood Flow And Coronary Flow Reserve

Detection Of Functional Significance of Coronary Stenoses Using Dynamic. Values Of Myocardial Blood Flow And Coronary Flow Reserve The 2nd International Symposium on Physics, Engineering and Technologies for Biomedicine Volume 2018 Conference Paper Detection Of Functional Significance of Coronary Stenoses Using Dynamic 13 N-Ammonia

More information

CORONARY ARTERY BYPASS GRAFTING (CABG) (Part 1) Mark Shikhman, MD, Ph.D., CSA Andrea Scott, CST

CORONARY ARTERY BYPASS GRAFTING (CABG) (Part 1) Mark Shikhman, MD, Ph.D., CSA Andrea Scott, CST CORONARY ARTERY BYPASS GRAFTING (CABG) (Part 1) Mark Shikhman, MD, Ph.D., CSA Andrea Scott, CST I have constructed this lecture based on publications by leading cardiothoracic American surgeons: Timothy

More information

Coronary artery disease (CAD) risk factors

Coronary artery disease (CAD) risk factors Background Coronary artery disease (CAD) risk factors CAD Risk factors Hypertension Insulin resistance /diabetes Dyslipidemia Smoking /Obesity Male gender/ Old age Atherosclerosis Arterial stiffness precedes

More information

Systolic and Diastolic Function After Patch Reconstruction of Left Ventricular Aneurysms

Systolic and Diastolic Function After Patch Reconstruction of Left Ventricular Aneurysms Systolic and Diastolic Function After Patch Reconstruction of Left Ventricular Aneurysms Tetsuji Kawata, MD, Soichiro Kitamura, MD, Kanji Kawachi, MD, Ryuichi Morita, MD, Yoshitsugu Yoshida, MD, and Junichi

More information

in Patients Having Aortic Valve Replacement John T. Santinga, M.D., Marvin M. Kirsh, M.D., Jairus D. Flora, Jr., Ph.D., and James F. Brymer, M.D.

in Patients Having Aortic Valve Replacement John T. Santinga, M.D., Marvin M. Kirsh, M.D., Jairus D. Flora, Jr., Ph.D., and James F. Brymer, M.D. Factors Relating to Late Sudden Death in Patients Having Aortic Valve Replacement John T. Santinga, M.D., Marvin M. Kirsh, M.D., Jairus D. Flora, Jr., Ph.D., and James F. Brymer, M.D. ABSTRACT The preoperative

More information

The Influence of Previous Percutaneous Coronary Intervention in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting

The Influence of Previous Percutaneous Coronary Intervention in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting Original Article The Influence of Previous Percutaneous Coronary Intervention in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting Toshihiro Fukui, MD, Susumu Manabe, MD, Tomoki Shimokawa, MD,

More information

Less Invasive, Continuous Hemodynamic Monitoring During Minimally Invasive Coronary Surgery

Less Invasive, Continuous Hemodynamic Monitoring During Minimally Invasive Coronary Surgery Less Invasive, Continuous Hemodynamic Monitoring During Minimally Invasive Coronary Surgery Oliver Gödje, MD, Christian Thiel, MS, Peter Lamm, MD, Hermann Reichenspurner, MD, PhD, Christof Schmitz, MD,

More information

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6 The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6 n&list_uids=17433949 64-Multislice Detector Computed Tomography Coronary Angiography as Potential Alternative

More information

Goals. Access flow and renal artery stenosis evaluation by Doppler ultrasound. Reimbursement. WHY use of Doppler Ultrasound

Goals. Access flow and renal artery stenosis evaluation by Doppler ultrasound. Reimbursement. WHY use of Doppler Ultrasound Access flow and renal artery stenosis evaluation by Doppler ultrasound Adina Voiculescu, MD Interventional Nephrology Brigham and Women s Hospital Boston Instructor at Harvard Medical School Understand

More information

Cardiac, Vascular and Transplant Surgery Quality Assessment. Intraoperative Ultrasound Imaging and TTFM

Cardiac, Vascular and Transplant Surgery Quality Assessment. Intraoperative Ultrasound Imaging and TTFM Cardiac, Vascular and Transplant Surgery Quality Assessment Intraoperative Ultrasound Imaging and TTFM Reduce risk of early graft failure, stroke, myocardial infarction or recurrent angina and provide

More information

Anatomic variants of the normal coronary artery circulation

Anatomic variants of the normal coronary artery circulation Diagnosis and Operation for Anomalous Circumflex Coronary Artery Keishi Ueyama, MD, PhD, Mahesh Ramchandani, MD, Arthur C. Beall, Jr, MD, and James W. Jones, MD, PhD Department of Surgery, Baylor College

More information

CPT Code Details

CPT Code Details CPT Code 93572 Details Code Descriptor Intravascular Doppler velocity and/or pressure derived flow reserve measurement ( vessel or graft) during angiography pharmacologically induced stress; each additional

More information

Intraoperative Surgical Guidance and Quality Assessment

Intraoperative Surgical Guidance and Quality Assessment Intraoperative Surgical Guidance and Quality Assessment For best surgical outcomes Improve surgical outcomes, demonstrate quality, and increase cost efficiency. The Medistim MiraQ Cardiac combines ultrasound

More information

Coronary Atherosclerosis in Valvular Heart Disease

Coronary Atherosclerosis in Valvular Heart Disease Coronary Atherosclerosis in Valvular Heart Disease Jerome Lacy, M.D., Robert Goodin, M.D., Daniel McMartin, M.D., Ronald Masden, M.D., and Nancy Flowers, M.D. ABSTRACT To evaluate the usefulness of routine

More information

Radiologic Importance of a High- Resistive Vertebral Artery Doppler Waveform on Carotid Duplex Ultrasonography

Radiologic Importance of a High- Resistive Vertebral Artery Doppler Waveform on Carotid Duplex Ultrasonography CME Article Radiologic Importance of a High- Resistive Vertebral Artery Doppler Waveform on Carotid Duplex Ultrasonography Esther S. H. Kim, MD, MPH, Megan Thompson, Kristine M. Nacion, BA, Carmel Celestin,

More information

Minimally invasive direct coronary artery bypass for left anterior descending artery revascularization analysis of 300 cases

Minimally invasive direct coronary artery bypass for left anterior descending artery revascularization analysis of 300 cases Original paper Videosurgery Minimally invasive direct coronary artery bypass for left anterior descending artery revascularization analysis of 300 cases Lufeng Zhang, Zhongqi Cui, Zhiming Song, Hang Yang,

More information

ery: Comparison of Predicted and Observed Resu ts

ery: Comparison of Predicted and Observed Resu ts Preoperative Risk Assessment in Cardiac Sur K ery: Comparison of Predicted and Observed Resu ts Forrest L. Junod, M.D., Bradley J. Harlan, M.D., Janie Payne, R.N., Edward A. Smeloff, M.D., George E. Miller,

More information

Assessment of Left Main Coronary Stenosis by Transesophageal Echocardiography

Assessment of Left Main Coronary Stenosis by Transesophageal Echocardiography Original Article Print ISSN: 2321-6379 Online ISSN: 2321-595X DOI: 10.17354/ijss/2018/250 Assessment of Left Main Coronary Stenosis by Transesophageal Echocardiography C Balachandran 1, T Viswanathan 1,

More information

It has been more than 10 years since the first clinical

It has been more than 10 years since the first clinical Limited Flow Capacity of the Right Gastroepiploic Artery Graft: Postoperative Echocardiographic and Angiographic Evaluation Masami Ochi, MD, Nobuo Hatori, MD, PhD, Masahiro Fujii, MD, Yoshiaki Saji, MD,

More information

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA SYMPOSIA Multislice CT Evaluation of Coronary Artery Bypass Graft Patients Robert Chapman Gilkeson, MD* and Alan H. Markowitz, MDw Abstract: Continuous improvement in multislice computed tomography technology

More information

Pulmonary Valve Replacement

Pulmonary Valve Replacement Pulmonary Valve Replacement with Fascia Lata J. C. R. Lincoln, F.R.C.S., M. Geens, M.D., M. Schottenfeld, M.D., and D. N. Ross, F.R.C.S. ABSTRACT The purpose of this paper is to describe a technique of

More information

Pallav J. Shah a, Manoj Durairaj a, Ian Gordon b, John Fuller c, Alex Rosalion a, Siven Seevanayagam a, James Tatoulis c, Brian F.

Pallav J. Shah a, Manoj Durairaj a, Ian Gordon b, John Fuller c, Alex Rosalion a, Siven Seevanayagam a, James Tatoulis c, Brian F. European Journal of Cardio-thoracic Surgery 26 (2004) 118 124 www.elsevier.com/locate/ejcts Factors affecting patency of internal thoracic artery graft: clinical and angiographic study in 1434 symptomatic

More information

Doppler Basic & Hemodynamic Calculations

Doppler Basic & Hemodynamic Calculations Doppler Basic & Hemodynamic Calculations August 19, 2017 Smonporn Boonyaratavej MD Division of Cardiology, Department of Medicine Chulalongkorn University Cardiac Center, King Chulalongkorn Memorial Hospital

More information

Relation of Saphenous Vein Graft Obstruction to Serum Cholesterol Levels

Relation of Saphenous Vein Graft Obstruction to Serum Cholesterol Levels JACC Vol. 25, No. 1 193 Janua~ 1995:193-7 Relation of Saphenous Vein Graft Obstruction to Serum Cholesterol Levels HIROYUKI DAIDA, MD, HISASHI YOKOI, MD, HIROSHI MIYANO, MD, HIROSHI MOKUNO, MD, HIROYUKI

More information

Demonstration of Uneven. the infusion on myocardial temperature was insufficient

Demonstration of Uneven. the infusion on myocardial temperature was insufficient Demonstration of Uneven in Patients with Coronary Lesions Rolf Ekroth, M.D., HAkan erggren, M.D., Goran Sudow, M.D., Josef Wojciechowski, M.D., o F. Zackrisson, M.D., and Goran William-Olsson, M.D. ASTRACT

More information

Anatomy is Destiny, But Physiology is Here Today

Anatomy is Destiny, But Physiology is Here Today Published on Journal of Invasive Cardiology (http://www.invasivecardiology.com) September, 2010 [1] Anatomy is Destiny, But Physiology is Here Today Thu, 9/9/10-10:54am 0 Comments Section: Commentary Issue

More information

F mary artery (IMA) graft carries a greater long-term

F mary artery (IMA) graft carries a greater long-term Internal Mammary Artery Grafts: The Shortest Route to the Coronarv Arteries J Thomas J. Vander Salm, MD, Sultan Chowdhary, MD,. N. Okike, MD, A. Thomas ezzella, MD, and Michael K. asque, MD University

More information

Is bypass surgery needed for elderly patients with LMT disease? From the surgical point of view

Is bypass surgery needed for elderly patients with LMT disease? From the surgical point of view CCT 2003 (Kobe) Is bypass surgery needed for elderly patients with LMT disease? From the surgical point of view Hitoshi Yaku, MD, PhD Department of Cardiovascular Surgery Kyoto Prefectural University of

More information

Further Evaluation. Technique of Coronary Artery Bypass. of the Circular Sequential Vein Graft

Further Evaluation. Technique of Coronary Artery Bypass. of the Circular Sequential Vein Graft Further Evaluation of the Circular Sequential Vein Graft Technique of Coronary Artery Bypass Joseph C. Cleveland, M.D., Ira M. Lebenson, M.D., Robert J. Twohey, M.D., Joseph G. Ellis, M.D., Daniel B. Nelson,

More information

Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting

Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in bypass grafting Yoshiyuki Takami, MD, Kazuyoshi Tajima, MD, Sachie Terazawa, MD, Noritaka Okada, MD, Kei Fujii, MD,

More information

Port-Access Coronary Artery Bypass Grafting With the Use of Cardiopulmonary Bypass and Cardioplegic Arrest

Port-Access Coronary Artery Bypass Grafting With the Use of Cardiopulmonary Bypass and Cardioplegic Arrest Port-Access Coronary Artery Bypass Grafting With the Use of Cardiopulmonary Bypass and Cardioplegic Arrest Hermann Reichenspurner, MD, PhD, Vassilios Gulielmos, MD, Jaqueline Wunderlich, MD, Markus Dangel,

More information

Radiologic Evaluation of Peripheral Arterial Disease

Radiologic Evaluation of Peripheral Arterial Disease January 2003 Radiologic Evaluation of Peripheral Arterial Disease Grace Tye, Harvard Medical School Year III Patient D.M. CC: 44 y/o male with pain in his buttocks Occurs after walking 2 blocks. Pain is

More information

and Coronary Artery Surgery George M. Callard, M.D., John B. Flege, Jr., M.D., and Joseph C. Todd, M.D.

and Coronary Artery Surgery George M. Callard, M.D., John B. Flege, Jr., M.D., and Joseph C. Todd, M.D. Combined Valvular and Coronary Artery Surgery George M. Callard, M.D., John B. Flege, Jr., M.D., and Joseph C. Todd, M.D. ABSTRACT Between July, 97, and March, 975,45 patients underwent combined valvular

More information

CPT Code Details

CPT Code Details CPT Code 93925 Details Code Descriptor Duplex scan of lower extremity arteries or arterial bypass grafts; complete bilateral study Lay Term The provider performs a duplex ultrasound scan of the lower extremity

More information

superior mesenteric artery aneurysm, transit-time doppler blood flow meter, internal iliac artery graft

superior mesenteric artery aneurysm, transit-time doppler blood flow meter, internal iliac artery graft Key words: superior mesenteric artery aneurysm, transit-time doppler blood flow meter, internal iliac artery graft Table 1 Laboratory data on admission superior mesenteric aneurysm (l0mm in diameter and

More information

Value of Index of Microvascular Resistance (IMR) in Microvascular Integrity

Value of Index of Microvascular Resistance (IMR) in Microvascular Integrity Value of Index of Microvascular Resistance (IMR) in Microvascular Integrity Seung-Woon Rha, Korea University Guro Hospital, Myeong-Ho Yoon, Ajou University Hospital Imaging & Physiology Summit 2009 Nov

More information

Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus

Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus ELSEVIER Early Human Development 40 (1995) 109-114 Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus P.B. Tsyvian a, K.V. Malkin

More information

FFR and CABG Emanuele Barbato, MD, PhD, FESC Cardiovascular Center Aalst, Belgium

FFR and CABG Emanuele Barbato, MD, PhD, FESC Cardiovascular Center Aalst, Belgium FFR and CABG Emanuele Barbato, MD, PhD, FESC Cardiovascular Center Aalst, Belgium Conflict of Interest Institutional research grants and speaker s fee from St. Jude Medical and Boston Scientic to Cardiovascular

More information