Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.
|
|
- Beverley Skinner
- 5 years ago
- Views:
Transcription
1 The feasibility of biphasic contrast-media-injection-protocol for chest imaging on 320-slice volume MDCT: Direct comparison of biphasic and bolus contrast-media injection protocols on 320-slice volume MDCT and 64-slice MDCT Poster No.: C-52 Congress: ECR 200 Type: Scientific Exhibit Topic: Contrast Media Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T. 2 Yoshikawa, M. Konishi, H. Koyama, M. Nogami, K. Sugimura ; 2 Kobe/JP, Berlin/DE Keywords: 320-slice MDCT, contrast administration, contrast media DOI: 0.594/ecr200/C-52 Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not available in the pdf version of presentations. Page of 7
2 Page 2 of 7
3 Purpose Introduction With the rapid development of multi-detector spiral computed tomography (MDCT), the contrast media injection protocol became more crucial. Recently, 320-detector row CT (i.e. area-detector CT) system has become clinically available. By using this CT system, the entire heart CT data can be obtained in a single rotation and within a single heartbeat. Thus, several investigators have reported the feasible contrast media injection protocols for computed tomography coronary angiography. As well as cardiac imaging, this CT system is also available for chest imaging by using non-spiral step and shoot scanning. In addition, no one discuss the feasible contrast media injection protocol for chest CT examination with this system. Purpose The purpose of this study was to determine the utility of the biphasic contrast media injection protocol on 320-detector row CT for chest CT examination, and reduction of total dose of contrast media on chest CT examination. Images for this section: Page 3 of 7
4 Fig. Page 4 of 7
5 Fig. 2 Page 5 of 7
6 Methods and Materials Materials and Methods Patient population 24 patients (3 male and female, mean age /- 4.2 years, mean body weight /- 5.8kg, mean body mass index /-.83) with chest disease were enrolled in this prospective study. They were diagnosed as having chest diseases as follows: lung cancers (n=7), thymic cysts (n=2), carcinoid (n=), thymoma (n=), sarcoidosis (n=), organizing pneumonia (n=), and chronic thromboembolic pulmonary hypertension (n=). All patients signed informed consent to participation. Exclusion criteria were general contraindication to iodinated contrast media. Materials and Methods CT 320-detector row CT All area-detector CT (Aquilion ONE, Toshiba Medical Systems, Ohtawara, Tochigi, Japan) examination was performed with non-ecg-gated step-and shoot scan protocol. Detail of scan protocol was as follows: detector collimation of mm, gantry rotation time 0.5 s, tube voltage 20 kv, tube current 270 ma, and 5 mm slice reconstruction). Scanning was performed in craniocaudal direction at end-inspiration 64-detector row CT All 64-slice MDCT (Aquilion 64, Toshiba Medical Systems, Ohtawara, Tochigi, Japan) examination was performed with non-ecg-gated helical scan protocol. Detail of scan protocol was as follows: detector collimation of mm, beam pitch 0.84, gantry rotation time 0.5 s, tube voltage 20 kvp, and tube current 300 ma. Scanning was performed in craniocaudal direction at end-inspiration. Contrast media injection protocol Dedicated biphasic-injection protocol Total 60 ml of Contrast media (Iopamiron370, Bayer Yakuhin, Osaka, Japan) was administered using a dual-head power injector (Daul Shot GX, Nemoto Kyorindo, Tokyo, Japan). At first phase, 40 ml of contrast material (370mgI/ml) was administered at constant flow rate of 2ml/s. Then, the concentration of contrast media was decreased for 20s from 2 to 0ml/s. At the same time period, the flow rate of saline was increased from 0 to 2 ml/s. Each scan was started with delay of 40 s. Bolus Injection Protocol Total 80 ml of Same contrast media was administered using a power injector (Auto Enhance A60, Nemoto Kyorindo, Tokyo, Japan) with bolus-injection protocol at a rate of 2ml/s. Each scan was also started with delay of 40 s. Page 6 of 7
7 Data analysis As quantitative analysis, the attenuation of following great vessels were measured in all patients using circular region of interest (ROI) positioned within the vessel lumen. Vena cava (Superior Vena Cava, Inferior Vena Cava) Right heart (right atrium, right ventricle) Pulmonary artery (pulmonary trunk, right main pulmonary artery, left main pulmonary artery) Left heart (left atrium, left ventricle) Aorta (ascending aorta, aortic arch, descending aorta). The attenuation were statistically compared each other between biphasic injection protocol on area-detector CT, bolus injection protocol on area-detector CT, and bolus injection protocol on 64-detector row CT by using Tukey-Kramer test. As qualitative analysis, image quality of each great vessel was also assessed by using five-point visual scale, and statistically compared with Fisher's PLSD test. Images for this section: Page 7 of 7
8 Fig. Page 8 of 7
9 Fig. 2 Page 9 of 7
10 Fig. 3 Page 0 of 7
11 Fig. 4 Page of 7
12 Results Results Quantitative analysis of attenuation of great vessels Attenuation of great vessels on biphasic injection protocol on area-detector CT (24.8 +/ HU, mean +/- standard deviation) was significantly higher than those on bolus injection protocols on area-detector CT (88.8 +/ HU, p<0.05) and 64-detector row CT (50.6 +/ HU, p<0.05). Qualitative analysis of visualization of great vessels The visual score of biphasic injection protocol (4.88 +/- 0.32, mean +/-standard deviation) was significantly higher than that on bolus injection protocols on area-detector CT (4.29 +/- 0.7, p<0.05) and 64-detector row CT (4.56 +/- 0.64, p<0.05). Images for this section: Page 2 of 7
13 Fig. Page 3 of 7
14 Fig. 2 Page 4 of 7
15 Fig. 3 Page 5 of 7
16 Conclusion Conclusion Biphasic contrast-media-injection protocol on 320-detector row CT has the potential to provide higher contrast attenuation and better image quality than bolus injection protocols on 320- and 64-detector row CT. Contrast media dose reduction may be achieved by using this biphasic protocol in routine clinical practice. Images for this section: Fig. Page 6 of 7
17 References. 2. Hein PA, et al. Initial experience with a chest pain protocol using 320 slice volume MDCT. Eur Radiol Behrendt FF, et al. Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT. AJR Am J Roentgenol Personal Information Page 7 of 7
64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes
64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes Poster No.: C-051 Congress: ECR 2009 Type: Scientific Exhibit Topic: Abdominal and Gastrointestinal Authors:
More informationMonophasic versus biphasic contrast application in CT of patients with head and neck tumour
Monophasic versus biphasic contrast application in CT of patients with head and neck tumour Poster No.: C-3331 Congress: ECR 2010 Type: Topic: Authors: Keywords: DOI: Scientific Exhibit Head and Neck G.
More information128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients
128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients Poster No.: C-0634 Congress: ECR 2010 Type: Scientific Exhibit Topic: Cardiac Authors: Y. H. Choe, J. W. Lee,
More informationHigh density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous?
High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous? Poster No.: C-1753 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit B. Y. Lee, H. R. KIM, J. I. Jung,
More informationA Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT
A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT Poster No.: C-0623 Congress: ECR 2017 Type: Authors: Keywords: DOI:
More informationFeasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate
Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Poster No.: B-0742 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Paper
More informationA pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography.
A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography. Poster No.: C-1787 Congress: ECR 2012 Type: Educational Exhibit Authors: N. Ahmed 1, G. Avery
More informationContrast enhancement of the right ventricle during coronary CTA: is it necessary?
Contrast enhancement of the right ventricle during coronary CTA: is it necessary? Poster No.: C-1545 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit M. Kok, C. Mihl, B. Kietselaer,
More informationPostmortem Computed Tomography Finding of Lungs in Sudden Infant Death.
Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death. Poster No.: C-1147 Congress: ECR 2013 Type: Educational Exhibit Authors: Y. Kawasumi, A. Usui, Y. Hosokai, M. Sato, A. Nakajima,
More informationAFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).
Feasibility, image quality and radiation dose of coronary CT angiography (CCTA) in patients with atrial fibrillation using a new generation 256 multi-detector CT (MDCT) Poster No.: C-2378 Congress: ECR
More informationDeath due to Hypothermia: Postmortem Forensic Computed Tomography.
Death due to Hypothermia: Postmortem Forensic Computed Tomography. Poster No.: C-1128 Congress: ECR 2012 Type: Educational Exhibit Authors: Y. Kawasumi, A. Usui, Y. Hosokai, M. Sato, H. Saito, T. Ishibashi,
More informationLow-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos
Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos Poster No.: C-3032 Congress: ECR 2010 Type: Scientific Exhibit Topic: Radiographers Authors: P.
More informationBolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography
Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography Poster No.: C-1342 Congress: ECR 2013 Type: Scientific Exhibit Authors:
More informationUtility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries
Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries Poster No.: C-0863 Congress: ECR 2015 Type: Scientific Exhibit Authors: A. Nakamoto,
More informationTriple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes
Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes Poster No.: C-0488 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit E.-J. Kang,
More informationContrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760
Can Weight-Adapted IV Contrast Media Protocols Reduce Iodine Dose and Still Produce a Diagnostic Contrast Enhancement Level in Abdomino-Pelvic CT Scans? Poster No.: C-1760 Congress: ECR 2015 Type: Authors:
More informationSlowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time
Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time Poster No.: C-208 Congress: ECR 2009 Type: Educational Exhibit Topic: Chest Authors:
More informationApplication of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax
Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax Poster No.: C-0013 Congress: ECR 2013 Type: Authors: Scientific Exhibit Z. Dejian 1, X. Zhuodong 2, J. Hui 2, L. Xiao 3 ;
More informationDiffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy
Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Poster No.: C-1785 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific
More informationECG Gated CT Aorta in Transcatheter Aortic Valve Implantation
ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation Poster No.: C-2014 Congress: ECR 2014 Type: Educational Exhibit Authors: M. A. Ottesen; Oslo/NO Keywords: Cardiac, Arteries / Aorta, CT, CT-Angiography,
More informationGastrointestinal Angiodysplasia: CT Findings
Gastrointestinal Angiodysplasia: CT Findings Poster No.: C-1792 Congress: ECR 2012 Type: Authors: Keywords: DOI: Educational Exhibit G. Anguita Martinez, A. Fernandez Alfonso, D. C. Olivares Morello, J.
More informationIdentification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine
Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine Poster No.: C-2125 Congress: ECR 2015 Type: Authors: Scientific Exhibit S. patil 1, A. M.
More informationScientific Exhibit Authors:
Clinical Audit on Optimization of Radiation Dose from MDCT: Effect on Diagnostic Reference Levels for Brain, Sinus, Cervical Spine, Chest, Abdomen-Pelvis, and Lumbar Spine Examinations and on Nationwide
More informationQuantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner.
Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner. Poster No.: C-2613 Congress: ECR 2015 Type: Authors: Keywords: DOI: Scientific Exhibit
More informationComputed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation.
Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation. Award: Poster No.: E-0004 Certificate of Merit Congress:
More informationChest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study
Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study Poster No.: C-1207 Congress: ECR 2013 Type: Scientific Exhibit Authors: Y. Shimomiya, M. Kondo, M.
More informationComparison of Cardiac MDCT with MRI and Echocardiography in the Assessement of Left Ventricular Function
Comparison of Cardiac MDCT with MRI and Echocardiography in the Assessement of Left Ventricular Function Poster No.: C-0969 Congress: ECR 2012 Type: Scientific Exhibit Authors: B. Kara, Y. Paksoy, C. Erol,
More informationTreatment options for endoleaks: stents, embolizations and conversions
Treatment options for endoleaks: stents, embolizations and conversions Poster No.: C-0861 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit G. Lombardi; napoli/it Arteries / Aorta, Abdomen,
More informationBottom up cardiac CT for CABG assessment to resolve breathing artefact
Bottom up cardiac CT for CABG assessment to resolve breathing artefact Poster No.: C-0589 Congress: ECR 2010 Type: Educational Exhibit Topic: Cardiac Authors: P. Glass, P. Donnelly, P. Hanley, D. Higginson,
More informationQuantitative imaging of hepatic cirrhosis on abdominal CT images
Quantitative imaging of hepatic cirrhosis on abdominal CT images Poster No.: C-0556 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit S. Kido, A. Nakamura, Y. Hirano; Ube/JP Cirrhosis,
More informationAetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH)
Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH) Poster No.: C-0964 Congress: ECR 2010 Type: Scientific
More informationArtifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil
Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil Poster No.: C-0671 Congress: ECR 2016 Type: Educational Exhibit Authors: H. Patel 1, W. Liu 2, J. DeSanto 2, S. Meagher 2, M. Zagardo 2,
More informationUozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462
Metal Artifact Reduction Algorithm enablesreduce metal artifacts and improvement of diagnosis in the postoperative Pedicle screws implant for Spinal Fusion: A Phantom Study Poster No.: C-0462 Congress:
More informationFDG-18 PET/CT - radiation dose and dose-reduction strategy
FDG-18 PET/CT - radiation dose and dose-reduction strategy Poster No.: C-1856 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit P. Nicholson, S. McSweeney, K. O'Regan; Cork/IE Radiation
More informationRadiation induced DNA double strand breaks undergoing PET/CT examinations.
Radiation induced DNA double strand breaks undergoing PET/CT examinations. Poster No.: C-1685 Congress: ECR 2011 Type: Scientific Exhibit Authors: M. S. May, M. Brand, T. Löwe, M. Sommer, C. Engert, U.
More informationComputational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology
Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology Poster No.: B-044 Congress: ECR 2011 Type: Scientific Paper Topic:
More informationHow to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained
How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained Poster No.: C-3077 Congress: ECR 2010 Type: Educational Exhibit Topic: Vascular Authors: D. V. Thomas; Northampton/UK
More information3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta
3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta Poster No.: C-1138 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Takahashi 1, Y. Takehara 2, H. Isoda
More informationDetectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT
Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT Poster No.: C-9 Congress: ECR 5 Type: Scientific Exhibit Authors: M. Nakadate, Y. Iwasa, M. Kishino, U. Tateishi;
More informationMetal Artifact Reduction by Dual Energy CT
Metal Artifact Reduction by Dual Energy CT Poster No.: C-0108 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper T. Johnson, F. Bamberg, A. Dierks, H.-C. Becker, M. F. Reiser; Munich/DE
More informationPurpose. Methods and Materials
Thin-section CT findings in peripheral lung cancer of 3 cm or smaller: are there any characteristic features for predicting tumor histology or do they depend only on tumor size? Poster No.: C-1893 Congress:
More informationPurpose. Methods and Materials. Results
Prevalence and significance of hypoattenuating hepatic lesions deemed too small to characterise: How are we following up these lesions and what are the outcomes? Poster No.: C-014 Congress: ECR 2009 Type:
More informationComputed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma
Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma Poster No.: C-0729 Congress: ECR 2013 Type: Scientific Exhibit Authors: A. Marin, I. Pozek,
More informationSingle cold nodule in Graves' disease: benign vs malignant
Single cold nodule in Graves' disease: benign vs malignant Poster No.: C-0073 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper L. I. Sonoda, M. Halim, K. Balan; Cambridge/UK Head and neck,
More informationRadiological features of Legionella Pneumophila Pneumonia
Radiological features of Legionella Pneumophila Pneumonia Poster No.: E-0048 Congress: ESTI 2012 Type: Scientific Exhibit Authors: M. Vinciguerra, L. Stefanetti, E. Teti, G. Argentieri, L. G. 1 1 1 1 1
More informationComputed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis
Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis Poster No.: C-1887 Congress: ECR 2016 Type: Authors: Keywords: DOI: Educational Exhibit M.
More informationUltra-low dose CT of the acute abdomen: Spectrum of imaging findings
Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings Poster No.: C-1452 Congress: ECR 2010 Type: Educational Exhibit Topic: GI Tract Authors: P. A. Vlachou, C. Kloeters, S. Kandel, P. Hein,
More informationA rare case: Coronary sinus thrombosis
A rare case: Coronary sinus thrombosis Poster No.: P-0085 Congress: ESTI 2014 Type: Educational Poster Authors: B. Özkul, N. Inan, Ö. Özkul, H. T. Sarisoy, G. Akansel, A. Akça, #. Çam; Kocaeli/TR Keywords:
More informationCT evaluation of small bowel carcinoid tumors
CT evaluation of small bowel carcinoid tumors Poster No.: C-0060 Congress: ECR 2015 Type: Educational Exhibit Authors: N. V. V. P. Costa, L. Nascimento, T. Bilhim ; Estoril/PT, PT, 1 2 3 1 2 3 Lisbon/PT
More informationMultislice CT versus cone beam CT: dosimetric and image quality comparision.
Multislice CT versus cone beam CT: dosimetric and image quality comparision. Poster No.: C-2589 Congress: ECR 2015 Type: Authors: Scientific Exhibit C. Dionisi 1, A. Crispo 2, E. Stefani 3, A. Lovaglio
More information3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy
3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy Poster No.: C-0493 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper A. LONG
More informationSingle ventricle on cardiac MRI
Single ventricle on cardiac MRI Poster No.: C-0414 Congress: ECR 2011 Type: Scientific Exhibit Authors: F. Secchi, V. G. Nardella, A. Giardino, G. Di Leo, F. 1 2 1 1 1 1 2 Sardanelli ; Milano/IT, Milan/IT
More informationComputed Diffusion-Weighted Image in the Abdomen
Computed Diffusion-Weighted Image in the Abdomen Poster No.: C-0234 Congress: ECR 2014 Type: Scientific Exhibit Authors: T. Yoshikawa 1, N. Aoyama 1, Y. Ohno 1, K. Kyotani 1, Y. Kassai 2, K. Sofue 1, M.
More informationOur experience in the endovascular treatment of female varicocele
Our experience in the endovascular treatment of female varicocele Poster No.: C-0347 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit A. Sáez de Ocáriz García, M. M. Mendigana Ramos,
More informationIdiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases
Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases Poster No.: P-0075 Congress: ESTI 2014 Type: Authors: Educational Poster J. J. Woo 1, K. Y. Lee 2, Y. Cho 1, J.
More informationComparison of CT findings between MDR-TB and XDR-TB
Comparison of CT findings between MDR-TB and XDR-TB Poster No.: C-0757 Congress: ECR 2017 Type: Authors: Keywords: DOI: Scientific Exhibit K. Yoon, H. Soohee; Changwon-si/KR Thorax, Lung, Respiratory system,
More informationAudit of CT Pulmonary Angiogram in suspected pulmonary embolism patients
Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:
More informationComparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma
Comparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma Poster No.: C-0245 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Yata,
More informationThe role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas.
The role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas. Poster No.: C-1319 Congress: ECR 2015 Type: Educational Exhibit Authors: R. Muslimov,
More informationUltrasonic evaluation of superior mesenteric vein in cancer of the pancreatic head
Ultrasonic evaluation of superior mesenteric vein in cancer of the pancreatic head Poster No.: C-1430 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit E. Fisenko, N. Vetsheva, E. Pershina;
More informationScientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2
Diagnosis of Acute Appendicitis: the role of Color Doppler Ultrasound as first-line imaging method and evaluation of the higher diagnostic performances of CT against its disadvantages. Poster No.: C-0708
More informationEthanol ablation of benign thyroid cysts and predominantly cystic thyroid nodules: factors that predict outcome.
Ethanol ablation of benign thyroid cysts and predominantly cystic thyroid nodules: factors that predict outcome. Poster No.: C-0322 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit J.
More informationRadiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital
Radiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital Poster No.: C-0892 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit A. Koo; Leeds, West Yorkshire/UK
More informationAudit of CT Pulmonary Angiogram in suspected pulmonary embolism patients
Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:
More informationPulmonary infarction semiology in CT. Revision of 80 cases.
Pulmonary infarction semiology in CT. Revision of 80 cases. Poster No.: C-0369 Congress: ECR 2012 Type: Scientific Exhibit Authors: M. González Vázquez, D. Castellon, J. Calatayud, N. Silva 1 2 1 1 1 1
More informationDiffusion-weighted MRI (DWI) "claw sign" is useful in differentiation of infectious from degenerative Modic I signal changes of the spine
Diffusion-weighted MRI (DWI) "claw sign" is useful in differentiation of infectious from degenerative Modic I signal changes of the spine Poster No.: C-0894 Congress: ECR 2012 Type: Scientific Exhibit
More informationPopliteal pterygium syndrome
Popliteal pterygium syndrome Poster No.: C-1816 Congress: ECR 2011 Type: Educational Exhibit Authors: L. B. S. Santos, J. L. D. O. Schiavon, O. O. Guimaraes Neto, 1 1 2 3 1 1 C. A. P. Braga, R. S. LEMOS,
More informationCoarctation of aorta in an adult-a case report
Coarctation of aorta in an adult-a case report Poster No.: P-0057 Congress: ESTI 2014 Type: Educational Poster Authors: R. Challa, R. Ahmed; Bolton/UK Keywords: Imaging sequences, CT, Thorax, Congenital
More informationPneumo-esophageal 64-MDCT technique for gastric cancer evaluation
Pneumo-esophageal 64-MDCT technique for gastric cancer evaluation Poster No.: C-1627 Congress: ECR 2010 Type: Scientific Exhibit Topic: GI Tract Authors: M. Ulla, E. Gentile, E. Levy, D. Cavadas, J. Ithurralde
More informationReliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures
Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures Poster No.: C-0669 Congress: ECR 2014 Type: Scientific Exhibit Authors: J. Tonak, I. Wobbe, R. L. Duschka,
More informationPulmonary changes induced by radiotherapy. HRCT findings
Pulmonary changes induced by radiotherapy. HRCT findings Poster No.: C-2299 Congress: ECR 2015 Type: Educational Exhibit Authors: R. E. Correa Soto, M. Albert Antequera, K. Müller Campos, D. 1 2 4 3 1
More informationTime efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT
Time efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT Poster No.: C-0636 Congress: ECR 2012 Type: Scientific Paper Authors: T. De
More informationThe Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities
The Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities Poster No.: C-1229 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit M. Osher 1, A. Pallas
More informationPurpose. Methods and Materials
Comparison of iterative and filtered back-projection image reconstruction techniques: evaluation of heavily calcified vessels with coronary CT angiography Poster No.: C-1644 Congress: ECR 2011 Type: Scientific
More informationSeemingly isolated greater trochanter fractures do not exist
Seemingly isolated greater trochanter fractures do not exist Poster No.: B-0950 Congress: ECR 2012 Type: Scientific Paper Authors: D. Dunker, J. H. Göthlin, M. Geijer ; Gothenburg/SE, Lund/SE Keywords:
More informationScientific Exhibit Authors: M. Sugiyama, Y. Takehara, T. Saito, N. Ooishi, M. Alley,
Abnormal flow dynamics within the ascending aorta of the patients with aortic valve stenosis. Assessments with phase resolved three dimensional phase contrast MR image (4DFlow). Poster No.: C-2504 Congress:
More informationAssessment of aortic distensibility with ECG-gated 64-row multi-detector computed tomography in abdominal aortic aneurysms
Assessment of aortic distensibility with ECG-gated 64-row multi-detector computed tomography in abdominal aortic aneurysms Poster No.: C-3106 Congress: ECR 2010 Type: Scientific Exhibit Topic: Vascular
More informationB. CT protocols for the spine
B. CT protocols for the spine Poster No.: A-003 Congress: ECR 2010 Type: Invited Speaker Topic: Neuro Authors: B. Tins; Oswestry/UK Keywords: CT, spine, diagnostic imaging protocol DOI: 10.1594/ecr2010/A-003
More informationCavitary lung lesion: Two different diagnosis with similar appearence
Cavitary lung lesion: Two different diagnosis with similar appearence Poster No.: P-0043 Congress: ESTI 2015 Type: Educational Poster Authors: M. Yesildag, H. Kalkan, K. Ödev; Konya/TR Keywords: Infection,
More informationAcute abdominal venous thromboses- the hyperdense noncontrast CT sign
Acute abdominal venous thromboses- the hyperdense noncontrast CT sign Poster No.: C-1095 Congress: ECR 2011 Type: Educational Exhibit Authors: M. Goldstein, K. Jhaveri; Toronto, ON/CA Keywords: Abdomen,
More informationComparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence
Comparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence Poster No.: C-1065 Congress: ECR 2015 Type: Authors: Keywords: DOI: Scientific Exhibit
More informationShear Wave Elastography in diagnostics of supraspinatus tendon.
Shear Wave Elastography in diagnostics of supraspinatus tendon. Poster No.: C-2168 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit V. Saltykova; Moscow/RU Musculoskeletal joint, Musculoskeletal
More informationValsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study.
Valsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study. Poster No.: C-0512 Congress: ECR 2012 Type: Authors: Keywords: DOI:
More informationAssessment of renal cell carcinoma by two PET tracer : dual-time-point C-11 methionine and F-18 fluorodeoxyglucose
Assessment of renal cell carcinoma by two PET tracer : dual-time-point C-11 methionine and F-18 fluorodeoxyglucose Poster No.: C-0805 Congress: ECR 2015 Type: Scientific Exhibit Authors: S. Ito, K. Kato,
More informationA time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction
A time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction Poster No.: C-0958 Congress: ECR 2013 Type: Scientific Exhibit Authors: F. Ciccarese, A.
More informationThe "whirl sign". Diagnostic accuracy for intestinal volvulus.
The "whirl sign". Diagnostic accuracy for intestinal volvulus. Poster No.: C-0670 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Pire, M. Marti, A. Borobia, A. Verón; Madrid/ES Keywords: Abdomen,
More informationSonographic and Mammographic Features of Phyllodes Tumours of the Breast: Correlation with Histological Grade
Sonographic and Mammographic Features of Phyllodes Tumours of the Breast: Correlation with Histological Grade Poster No.: C-0046 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit C. Y.
More informationBI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation
BI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation e-poster: C-118 Congress: ECR 2008 Type: Educational Exhibit Topic: Breast / Ultrasound Authors:
More informationAnatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study
Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study Poster No.: R-0016 Congress: 2015 ASM Type: Scientific Exhibit Authors: J. Au, A. Webb, G. Buirski, P. Smith, M. Pickering, D.
More informationStandardizing mammographic breast compression: Pressure rather than force?
Standardizing mammographic breast compression: Pressure rather than force? Poster No.: C-2383 Congress: ECR 2012 Type: Authors: Scientific Paper J. E. de Groot 1, W. Branderhorst 1, M. Broeders 2, G. J.
More informationSmall-bowel obstruction due to bezoar: CT diagnosis and characterization
Small-bowel obstruction due to bezoar: CT diagnosis and characterization Poster No.: C-1450 Congress: ECR 2013 Type: Scientific Exhibit Authors: I. lópez blasco, S. Paz Maya, R. Dosdá Muñoz, D. Soriano
More informationHow to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter
How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter Poster No.: C-0281 Congress: ECR 2013 Type: Scientific
More informationHyperechoic breast lesions can be malignant.
Hyperechoic breast lesions can be malignant. Poster No.: C-0041 Congress: ECR 2015 Type: Educational Exhibit Authors: G. Babu, R. bradley; Edinburgh/UK Keywords: Breast, Ultrasound, Biopsy, Cancer DOI:
More informationAcute Pancreatitis, its Complications and Prognostic Correlation by Modified CT Severity Index
Acute Pancreatitis, its Complications and Prognostic Correlation by Modified CT Severity Index Poster No.: R-0022 Congress: RANZCR-AOCR 2012 Type: Scientific Exhibit Authors: K. P. Bellam Premnath, K.
More informationPage 1 of 8. 4 Charleston, SC/US
Comparison of contrast-induced discomfort between Visipaque (Iodixanol) injection 320 mg I/mL and Isovue (Iopamidol) 370 mg I/mL in patients undergoing peripheral arteriography Poster No.: C-1976 Congress:
More informationWhirlpool sign of testis, a sonographic sign of incomplete torsion
Whirlpool sign of testis, a sonographic sign of incomplete torsion Poster No.: C-0965 Congress: ECR 2011 Type: Educational Exhibit Authors: F. Esposito, P. Sgambati, M. Di Serafino, D. Noviello, G. 1 3
More informationCT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience
CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience Poster No.: C-0097 Congress: ECR 2016 Type: Scientific Exhibit Authors: A. Casarin, G. Rech, C. Cicero, A.
More informationOverview of physiological post-mortem alterations in totalbody imaging of 100 in-hospital deceased patients
Overview of physiological post-mortem alterations in totalbody imaging of 100 in-hospital deceased patients Poster No.: C-1234 Congress: ECR 2016 Type: Scientific Exhibit Authors: I. Wagensveld, W. Oosterhuis,
More informationDual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study
Dual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study Poster No.: C-2279 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Guzi#ski,
More informationDEXA Scores and Bone Density Measured on Routine CT Scans
DEXA Scores and Bone Density Measured on Routine CT Scans Poster No.: R-0072 Congress: 2015 ASM Type: Scientific Exhibit Authors: C. Annabattula, P. Phadke; Sydney/AU Keywords: Screening, Nuclear medicine
More information