ABSTRACT R.D. MOORE, D.O., F.A.C.O.G., F.A.C.S. DIRECTOR, ADVANCED PELVIC SURGERY DIRECTOR, UROGYNECOLOGY ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA

Size: px
Start display at page:

Download "ABSTRACT R.D. MOORE, D.O., F.A.C.O.G., F.A.C.S. DIRECTOR, ADVANCED PELVIC SURGERY DIRECTOR, UROGYNECOLOGY ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA"

Transcription

1 Single-Center Retrospective Study of the Technique, Safety, and 12-Month Efficacy of the MiniArc Single-Incision Sling: A New Minimally Invasive Procedure for Treatment of Female SUI R.D. MOORE, D.O., F.A.C.O.G., F.A.C.S. DIRECTOR, ADVANCED PELVIC SURGERY CO-DIRECTOR, UROGYNECOLOGY ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA G.K. MITCHELL, M.D., F.A.C.O.G. STAFF PHYSICIAN ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA J.R. MIKLOS, M.D., F.A.C.O.G., F.A.C.S. DIRECTOR, UROGYNECOLOGY ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA ABSTRACT This study was conducted to report on the technique, safety, and early efficacy of a single-incision minisling to treat female stress urinary incontinence (SUI). Women suffering from SUI were offered a singleincision approach to place a suburethral polypropylene mesh tape in a position similar to that of a transobturator sling without passage of needles through the groin. Retrospective data was collected on 61 patients that received the new MiniArc single-incision sling at a single center in the United States. Patient selection and concomitant procedures were determined by the senior authors at the center, and the senior authors were the primary surgeons in all cases. Procedures were completed under general, regional, or MAC anesthesia as determined by the surgeon. Average operative time for the sling procedure alone was short and the average blood loss was 29 cc. There were no intraoperative complications. There was one postoperative adverse event secondary to urinary retention that was resolved by loosening of the sling under local anesthesia in an office setting. The overall cure rate at 12 months determined by physician and patient assessment in 58/61 patients was 91.4%. No patients suffered pain or dyspareunia secondary to the sling, and no erosions or extrusions were reported. In this initial study, the MiniArc single-incision sling appears to be a safe approach to treat female SUI, and the early clinical results are encouraging

2 Single-Center Retrospective Study of the Technique, Safety, and 12-Month Efficacy of the MiniArc Single-Incision Sling MOORE, MITCHELL, MIKLOS Stress urinary incontinence (SUI) is estimated to affect between 4% and 35% of adult women worldwide, and can lead to deterioration in the quality of life of those affected. 1 Over the years, various surgical treatments have been shown to be effective in treating SUI, including colposuspension (Burch, MMK) and traditional pubovaginal sling procedures using various materials and various methods of securing the sling in place. The introduction of tension-free vaginal tape (TVT; Gynecare, Johnson & Johnson, Sommerville, NJ) in 1996 revolutionized the treatment of SUI with a minimally invasive procedure that could be completed under local anesthesia in an outpatient setting. 2 The TVT procedure and subsequent similar tension-free sling products such as the SPARC procedure (American Medical Systems, Minnetonka, MN) have been shown to have excellent cure rates and have provided women with less invasive options for treatment; however, even with these minimally invasive techniques surgical complications still arise. 3 The blind retropubic needle approach used with these techniques has been associated with a variety of intra- and postoperative complications, including bladder perforation, pain, voiding dysfunction, and de novo urge symptoms. Other rare but potentially serious injuries to the urethra, bowel, or arteries and nerves in the retropubic space as a INTRODUCTION well as mortalities attributed to either major vascular or bowel injury have also been reported. 4 Initially described by Delorme in 2001, the transobturator approach for tension-free sling placement (TOT) was developed in an attempt to reduce the potential for complications associated with the retropubic access route inherent to the prior tape procedures. 5 Since its introduction, the transobturator approach has increased in popularity because of the ease of the approach and the safety advantages inherent in avoiding the blind retropubic needle passage. The TOT sling has also been shown to be an effective minimally invasive procedure for SUI; studies to date have shown similar cure rates and fewer complications when compared with the retropubic approach Anatomically, the transobturator sling lies in a position that more closely mimics the natural position of the pubourethral ligament, and therefore is thought to cause less voiding dysfunction and obstruction than the retropubic sling while still maintaining its effectiveness in the treatment of SUI. Despite the less invasive approach of the TOT sling and its encouraging clinical results, the procedure has not been proven to be risk-free. One of the concerns of the procedure is the development of clinically significant groin pain following the passage of needles and mesh through the transobturator space and the medial groin beneath the adductor longus tendon Although the Figure 1. MinArc mini-sling by American Medical Systems. Note the self-fixating tip at the end of the macroporous polypropylene tape. Once the tip is fixated into the obturator muscle, the needle slides out easily. (Copyright and reproduced with permission from American Medical Systems.) b risk is low, the complication can be debilitating when it does occur; therefore, the search for an even less invasive approach to place a tension-free vaginal tape sling has continued. The logical next step toward a less invasive, mid-urethral, tension-free tape sling is one that is placed through a single vaginal incision without any needle passage through the abdomen or groin. If adequate fixation of the tape in a similar position can be accomplished without needle passage through the abdomen or groin, this should provide safer placement without compromising cure rates. This current chapter is a description of the MiniArc Single- Incision Sling (American Medical Systems) and a single-center retrospective study of the safety and short-term efficacy of this minimally invasive treatment for female SUI. MATERIALS AND METHODS Sixty-one consecutive patients at our urogynecology center in Atlanta, Georgia, underwent placement of the MiniArc single-incision sling for treatment of female SUI from March to November The two senior authors completed all procedures and both surgeons had previous experience placing the TVT-Secur (Gynecare) mini-sling, which was released in the United States in the fall of The safety and effectiveness of the procedure in consecutive patients were evaluated by retrospective chart review after their 12-month visit. Patient selection was determined by the individual surgeons, and the only inclusion criteria were the diagnosis of SUI. Concomitant procedures were also completed as deemed necessary by the individual surgeons. SUI was confirmed preoperatively by the surgeons with subjective assessment of patients complaints in addition to cough stress test or complex urodynamics. Our center uses qualityof-life (QOL) questionnaires as part of the routine protocol, including the Urogenital Distress Inventory Short Form (UDI-6) both pre- and postoperatively, therefore this was also included in the analysis. Intra- and postoperative safety parameters or any notations of complications were included in the analysis of records. Postoperative continence was determined subjectively by patient and - 2 -

3 physician during the follow-up timeframe of 12 months using standard questionnaires and patient interviews. Other parameters evaluated included urinary urge symptoms (taken from the QOL forms), time of catheter use, pain at site of implant, infection, mesh extrusion, sling revisions, or any other sling-related complications noted. SURGICAL SURGICAL PROCEDURE The MiniArc procedure can be completed under local, MAC, or general anesthesia in a hospital, outpatient surgery center, or office setting. A 1.5- cm incision is made in the suburethral region. This incision is identical to the incision made for the Monarc (American Medical Systems) transobturator sling or other similar tension-free vaginal tape slings. The vaginal epithelium is dissected off the underlying suburethral tissues out to the pelvic sidewall, just on the posterior surface of the ischiopubic ramus. This dissection follows the same path of that for the Monarc sling but can be made only just slightly wider than the mesh to avoid full dissection. The tunnel that is created should be wide enough to ensure the mesh lies flat under the urethra and to avoid button holing the vaginal sulcus. The MiniArc sling s self-fixating tip is then attached to the curved blunt needle tip to advance the sling into place (Fig. 1). Once attached, the needle is then placed into the dissected tunnel and directed toward the obturator space at approximately a 45 angle. The final trajectory and position is similar to the hammock type position of the Monarc transobturator sling (Figs. 2, 3, 4). The needle tip is actually directed toward the same position in the groin that the transobturator sling incision would be made. Once the pelvic sidewall is penetrated (i.e., the obturator fascia and obturator internus muscle), the needle is advanced until the midpoint of the sling is at the mid-urethra, or just beyond the mid-urethra. The final position of the sling tip should be in the obturator internus muscle. The needle is then easily removed simply by sliding it back out of the fixating tip. Due to the tip s slip-fit design, the sling does not move during disengagement of the needle from the sling. The other side is then completed in Figure 2. Placement of the MiniArc needle in a bony pelvis. Note the direction of the needle is toward the obturator space, which will place the sling in a hammock position that is the same position of the TOT sling. Figure 3. Final position of the MiniArc mini-sling in a hammock-type position under the urethra. (Copyright and reproduced with permission from American Medical Systems.) Figure 4. Lateral view of the MiniArc sling in position under the mid-urethra with the self-fixating tip in the obturator internus muscle. (Copyright and reproduced with permission from American Medical Systems.) - 3 -

4 Single-Center Retrospective Study of the Technique, Safety, and 12-Month Efficacy of the MiniArc Single-Incision Sling MOORE, MITCHELL, MIKLOS the needle to the self-fixating tip if the sling must be tightened further. Once the final adjustment is accomplished, the vaginal epithelium is then closed with absorbable sutures. Cystoscopy is left to the discretion of the surgeon. RESULTS RESULTS Figure 5. The TVT-Secur device. (Copyright and reproduced with permission from Gynecare.) an identical fashion. The needle is slowly advanced into the obturator muscle until a tension-free adjustment is completed under the mid-urethra. The design of the self-fixating tip and curved needle provide the surgeon excellent control in advancing the needle to obtain precise, tension-free adjustment under the mid-urethra. It is recommended the sling is placed flat against the urethra using a hemostat or other instrument to help guide appropriate tensioning without overtightening the sling. If the patient is under MAC or local anesthesia, a cough test for adjustment of the sling can be completed. The bladder is filled with 250 cc of fluid prior to placement of the second side of the sling. The second side of the sling is then advanced just into the sidewall and the needle is left engaged with the selffixating tip, and the patient is asked to cough. The needle is then sequentially advanced into the obturator internus muscle until there is no longer any leakage with cough. The sling is also equipped with an optional re-docking feature for adjustment that uses a 2-0 Prolene suture that enables the surgeon to go back to the first side and re-dock Table I Demographic and Urodynamic Data (N = 60) Patient Demographics Average age (years) 58 Range: Average weight (lbs) Range: Average parity 2.64 Range: 0 6 Average leak point pressure Average urethral pressure Urodynamic Parameters mmhg mmhg Patients with leak point pressure? 65 mmhg 26 (49%) Patients with urethral press? 20 mmhg 6 (10.7%) *Not all patients reported values Patient demographic data can be seen in Table 1. Average patient age was 58 years (range: 26 to 84 years) with an average weight of lbs (range: 120 to 240 lbs). Urodynamic parameters are also seen in Table 1. The average leak point pressure (LPP) was cm- H 2 O, and the urethral closure pressure (UCP) was 39.6 cm-h 2 O. Forty-nine percent of patients were considered to have intrinsic sphincter deficiency by LPP (less than 65) and 10.7% by UCP (less than 20). All implants occurred in a hospital setting under either general (56%), regional (23%), or MAC (21%) anesthesia with local infiltrate per surgeon discretion. A total of 56 out of 61 patients (92%) had concomitant repairs at the time of sling placement. Average blood loss for the MiniArc procedure alone was estimated to be 29 cc (range: 10 to 99 cc; Table 2). Cystoscopy was completed at the end of the procedure in all cases. There were no intraoperative complications reported, including no incidence of bladder or urethral injury and no incidence of postoperative bleeding or hematoma formation. The average time to return to normal voiding was 2.4 days, with 83% of patients voiding normally by 72 hours (Table 3). Two patients required extended catheterization secondary to bladder injuries during other procedures unrelated to the MiniArc. Only one patient required revision/loosening of the sling for urinary retention, and this was completed in the office at 2 weeks postoperatively. This resolved her voiding dysfunction without sequelae, and at 12 months follow-up she reported no voiding dysfunction and was cured of her SUI. Twelve-month follow-up was completed on 58 of the 61 patients implanted. Three patients were lost to follow-up. Postoperatively, there have been no reports of pain, mesh extrusions, or other sling-related complications. None of the self-fixating tips could be palpated on vaginal exam and - 4 -

5 Table II MiniArc Procedural Parameters (N = 61) Subjects implanted with MiniArc 61 (100%) Estimated blood loss (ml) Mean ± s.d. 29 ± 16 Range Anesthesia type Epidural 14/61 (23%) General 34/61 (56%) MAC with local 13/61 (21%) Concomitant procedures 56/61 (92%) Subjects with MiniArc implant complications 0/61 (0%) *All procedures in hospital setting there were no reports of pain during palpation of the surgical implant site on follow-up exam, including palpation of where the self-fixating tip penetrates the sidewall. There were no reports of dyspareunia that were sling related. No patients required revision or removal of the sling for pain, dyspareunia, infection, or rejection. Using both physician and patient assessment of cure, the overall cure rate was 91.4% (53 of 58 patients considered cured of SUI symptoms). Three patients were outright failures, with no improvements in their symptoms. One of these had a TOT sling that resolved her symptoms, and the other two are considering revision. The other two Table III Average Time to Void patients that were considered failures were both significantly improved of their SUI symptoms and are happy with their results, and do not want revision or further treatment. Urinary urgency and frequency symptoms were significantly present in 52% of patients preoperatively and in only 14% of patients postoperatively (75% resolution of urgency/frequency symptoms). Patient quality of life was also significantly improved after MiniArc sling placement with overall QOL scores (UDI-6) showing statistically significant improvement on the assessment questionnaire total scores. UDI-6 total scores decreased from an average of 41.8 ± 24.9 preoperatively to 11.2 ± 13.8 Time Patients % of Total < 24 hours 29 48% < 48 hours 9 15% < 72 hours 12 20% 96 hours 3 5% 5 days 4 7% 6 days 1 2% 7 days 1 2% 9 days 1 2% ISC 2 wks 1 2% Totals % postoperatively (p < 0.001). Only 2 out of 57 (3.5%) reported de novo urgency or frequency symptoms on their UDI-6 questionnaire. DISCUSSION DISCUSSION Treatment for female SUI has seen revolutionary changes in the last ten years, with new minimally invasive techniques that have been proven safe and effective. The TVT sling was first developed and then the TOT sling followed, which provided a safer means to place a tension-free mesh tape sling with seemingly equivalent cure rates and lower rates of bladder injury and voiding dysfunction. The TOT has been shown to be an effective minimally invasive procedure for SUI in which retrospective studies have shown cure rates between 85% and 95%, and seemingly have fewer complications compared with the retropubic approach. 6 8 They have gained popularity over the original retropubic TVT procedures because they eliminate the need to blindly pass a needle through the retropubic space and therefore minimize the risk of major vascular, bladder, or bowel injury. In one of the largest worldwide multicenter prospective studies to date, the Monarc TOT sling was shown to have an objective cure rate of 91.8% at 12 months. 9 Prospective randomized trials comparing TOT slings to TVT slings have shown equivalent cure rates and decreased complications with the TOT sling approach Anatomically, the transobturator sling lies in a hammock type position that mimics the pubourethral ligament, and therefore is thought to cause less voiding dysfunction or obstruction, fewer urge symptoms, and less anticholinergic use postoperatively than the retropubic slings, which has been confirmed in comparative studies. 15,16,22 De novo urge symptoms are often associated with surgical procedures for SUI. Published literature to date indicates that de novo urge incontinence was noted in 0.8% to 25.9% of patients undergoing TVT procedures. 4 This wide range was attributed to a variation in the definition of urge symptoms in the various studies. Some surgeons speculate that with the proximity of the TVT sling to the bladder due to the - 5 -

6 Single-Center Retrospective Study of the Technique, Safety, and 12-Month Efficacy of the MiniArc Single-Incision Sling MOORE, MITCHELL, MIKLOS retropubic passage, the sling may actually penetrate or irritate the bladder detrusor muscle, causing detrusor instability in some cases. The TOT sling is subfascial, avoiding the retropubic space, and lies in a hammock-type position under the urethra, which may be the reason there seems to be less obstruction and voiding dysfunction with this type of approach. However, even though the TOT sling seems to be a safer approach with fewer side-effects than retropubic placement, it is not risk-free as groin pain has been reported in some series, particularly with the inside-to-out transobturator approach In a recent prospective randomized trial comparing the TVT-O ( inside-out ) to the Monarc ( outsidein ) TOT procedure, the TVT-O was found to be significantly more painful and the pain lasted significantly longer compared to the Monarc procedure. 21 The source of the postoperative pain with the inside-out approach was attributed to a less predictable, more lateral needle passage through the groin with a closer exit to the obturator nerve. In attempts to make the procedure even less invasive by eliminating needle passages required through the abdomen or groin, the single-incision MiniArc sling has been developed. This is the next logical step in the progression of minimally invasive sling techniques. The TVT-Secur was the first mini-sling released in late 2006; however, initial results have not been as promising as hoped with cure rates in the range of 69% to 82% This has also been confirmed in studies with longer follow-up as well, and may be secondary to the design of the kit and not the procedure itself. 26,27 Debodinance et al. reported prospectively on 110 patients and found the objective cure rate for the TVT-Secur to be 70.6%, and concluded that the results are not as good as TVT or TVT-O. 27 In the authors early experience with the TVT-Secur device, we found difficulty in releasing the trocar away from the mesh once placed in the sidewall, which at times caused the sling to loosen and altered the initial tensioning placed. This and a greater learning curve have also been reported by others in early reports. 28,29 Additionally, the TVT- Secur is placed with the assistance of a bladed trocar, which is more traumatic and wider than the MiniArc system (Fig. 5). A case report was recently published describing severe hemorrhage from the internal obturator muscle after placement of the TVT-Secur device that required laparotomy and drainage of 1000 cc of blood from the retropubic space and oversew of the bleeding muscle, and was thought to be secondary to this sharp-bladed trocar. 30 The new MiniArc single-incision sling shows very promising early clinical results and is one of the least invasive slings to be released to date. It uses the same mesh that has been proven safe in many clinical studies with the Monarc and SPARC sling procedures and also the same positioning of the mesh tape in a subfascial hammock type position of the TOT approach. However, the system uses a unique polypropylene selffixating tip on the end of the mesh to fixate the tape in place in the obturator muscle and fascia, therefore eliminating the need to pass needles through the groin, obturator space, or medial adductor muscles. Theoretically, this should translate to a decreased risk of groin pain or other groin complications such as infections, a result that was confirmed in this study where no patients complained of any postoperative groin pain attributable to the sling and in which were no reports of any groin infections or complications. The procedure also has the advantage of a smaller, less traumatic delivery system compared to other currently available systems; it is very simple to use and easy to control placement and adjustment/advancement of the sling into the pelvic sidewall, with minimal trauma and bleeding. In an initial U.S. multicenter retrospective study, overall objective and subjective cure rates were in the range of 93% at 12 weeks with minimal complications reported and an average blood loss of 27 cc. 31 The current study confirms these findings and shows that the cure rates are holding up over the first year. The average blood loss in the current study was only 29 cc with no reports of postoperative bleeding or hematomas either vaginally or in the obturator space. Postoperative pain was minimal, with no patient reporting pain with palpation of the sling placement site either sub-urethrally, paraurethrally, or at the insertion site of the self-fixating tip in the sidewall during follow-up exams. One of the concerns with any modification of the tension-free tape sling procedure is short-term fixation until tissue in-growth can occur to fixate the entire sling in position, as this could affect cure rates. If the sling is loosened during release of the placement device or during the immediate postoperative period from patient movement, coughing, straining, and so on prior to tissue in-growth occurring throughout the entire length of the sling, then this may translate to lower cure rates. Fixation with the MiniArc system seems to be excellent and immediate; furthermore, the sling does not move with the release of the placement needle. Once placed, the self-fixating tip seems to secure into the sidewall muscle and tissues very well, and although possible to loosen if necessary in the intra-adjustment of the sling, this can be difficult because of the excellent fixation. This immediate fixation should help hold the sling in place during the healing phase and therefore translate to similar cure rates of TOT slings given its similar position in the pelvis and sidewall musculature. This was preliminarily confirmed clinically in the current study with cure rates in the range of 91.4%, which is consistent with what has been reported to date with the traditional transobturator approach. Of course, this is only a short-term cure rate with small numbers and longerterm, prospective studies are needed; however, our feeling is that if the tape is in the same position as the traditional TOT sling and is fixated well enough to have adequate cure rates at 12 months, then we are optimistic that these cure rates should hold up over longer-term follow-up. The sling should also still offer the same benefits of the hammock-type positioning of the traditional TOT sling, including minimal voiding dysfunction and low rates of urinary retention and sling loosening or release. This was also confirmed in the current study with most patients returning to voiding by Day 3 and only one patient requiring loosening or revision. Overall urge symptoms were also significantly reduced from baseline with 75% of patients reporting significant urge symptoms preoperatively having a resolution of these symptoms postoperatively. De novo urge symptoms were also very minimal, with only 3.5% reporting new significant urge symptoms postoperatively

7 CONCLUSIONS CONCLUSIONS The MiniArc sling is a new minimally invasive, single-incision sling for treatment of female SUI. The procedure can be performed under local anesthesia with or without a cough test, or under general anesthesia per surgeon discretion. Early clinical results in the current trial show it to be a safe and effective minimally invasive procedure for female SUI with cure rates at 12 months in the range of 91.4%. There were no reports of any postoperative complications such as infection, erosion, hematoma, groin pain, or dyspareunia secondary to the sling. Further investigation with longer-term followup and prospective studies are ongoing and will add to the previous data; however, it does appear in initial studies that the MiniArc sling may offer equivalent efficacy with a less invasive approach than the current procedures being used today and may be the next step in minimally invasive treatment of female SUI. STI REFERENCES REFERENCES 1. Luber KM, The definition, prevalence, and risk factors for stress urinary incontinence. Rev Urol 2004;6 Suppl 3:S Ulmsten U, Henriksson L, Johnson P, Varhos G. An ambulatory surgical procedure under local anesthesia for treatment of female urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 1996;7:81-5, disc Deval B, Levardon M, Samain E, Rafii A, et al. A French multicenter clinical trial of SPARC for stress urinary incontinence. Eur Urol 2003;44: Ward K, Hilton P. Minimally invasive synthetic suburethral slings: emerging complications. Obstetr Gynaecol 2005;7: Delorme E. Transobturator urethral suspension: mini-invasive procedure in the treatment of stress urinary incontinence in women. Prog Urol 2001;11: Mellier G, Benayed B, Bretones S, Pasquier JC. Suburethral tape via the obturator route: is the TOT a simplification of the TVT? Int Urogynecol J Pelvic Floor Dysfunct 2004;15: Morey AF, Medendorp AR, Noller MW, et al. Transobturator versus transabdominal mid urethral slings: a multi-institutional comparison of obstructive voiding complications. J Urol 2006;175: Davila GW, Johnson JD, Serels S. Multicenter experience with the Monarc transobturator sling system to treat stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 2006;17(5): Moore RD, Miklos JR, Cervigni M, et al. Monarc transtobturator sling: combined analysis of 1 year follow-up in 9 countries with 266 patients. Int Urogynecol J Pelvic Floor Dysfunct 2006;17:S Daraï E, Frobert JL, Grisard-Anaf M, et al. Functional results after the suburethral sling procedure for urinary stress incontinence: a prospective randomized multicentre study comparing the retropubic and transobturator routes. Eur Urol 2007;51(3): , disc Lee KS, Han DH, Choi YS, et al. A prospective trial comparing tension-free vaginal tape and transobturator vaginal tape inside-out for the surgical treatment of female stress urinary incontinence: 1-year followup. J Urol 2007;177(1): Dietz HP, Barry C, Lim Y, Rane A. TVT vs. Monarc: a comparative study. Int Urogynecol J Pelvic Floor Dysfunction 2006;17(6): Barber MD, Kleeman S, Karram MM, et al. Transobturator tape compared with tension-free vaginal tape for the treatment of stress urinary incontinence: a randomized controlled trial. Obstet Gynecol 2008 Mar;111(3): Rinne K, Laurikainen E, Kivela A, et al. A randomized trial comparing TVT with TVT- O: 12 month results. Int Urogynecol J 2008;19: Barber MD, Gustilo-Ashby AM, Chen CC, et al. Perioperative complications and adverse events of the MONARC transobturator tape, compared with the tension-free vaginal tape. Am J Obstet Gynecol 2006;195(6): Collinet PC, Ciofu CC, Cosson MC, Jacquetin BJ. Safety of inside-out transobturator approach for SUI: multicentric prospective study of 994 patients-french TVT-O registry. Int Urogynecol J Pelvic Floor Dysfunct 2006;17:S Lim J, Cornish A, Carey MP. Clinical and quality-of-life outcomes in women treated by the TVT-O procedure. BJOG 2006;113(11): Achtari C, McKenzie BJ, Hiscock R, et al. Anatomical study of the obturator foramen and dorsal nerve of the clitoris and their relationship to minimally invasive slings. Int Urogynecol J Pelvic Floor Dysfunct 2006;17: Delmas V. Anatomical risks of transobturator suburethral tape in the treatment of female stress urinary incontinence. Eur Urol 2005;48: Costa P, Delmas V. Trans-obturator-tape procedure-"inside out or outside in": current concepts and evidence base. Curr Opin Urol 2004;14: But I, Faganelj M. Complications and short term results of two different transobturator techniques for surgical treatment of women with stress urinary incontinence: a randomized trial. Int Urogynecol J Pelvic Floor Dysfunct 2008;19: Botros SM, Miller JJ, Golberg RP, et al. Detrusor overactivity and urge urinary incontinence following transobturator versus midurethral slings. Neurourol Urodyn 2007;26(1): Salz SM, Haff RE, Lucente VR. Shortterm assessment of patients undergoing the new tension free vaginal tape: Secur procedure for SUI. Int Urogynecol J Pelvic Floor Dysfunc 2007;18:S Albrich S, Nauman G, Skala C, Koelbl H. TVT-Secur: a novel approach for the treatment of female genuine stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunc 2007;18:S Marsh FA, Assassa P. An audit of the introduction of TVT Secur in clinical practice. Int Urogynecol J Pelvic Floor Dysfunc 2007;18:S Meschia M, Barbacini P, Pifarotti P, et al. Multicenter prospective trial of TVT Secur for the treatment of primary stress incontinence. Int Urogyncolog J 2008;19:S Debodinance P, Lagrange E, Amblard J, et al. TVT Secur: more and more minimally invasive. Preliminary prospective study of 110 cases. J Gynecol Obstet Biol Reprod 2008;37(3): Saltz S, Mitchell G, Haff R, et al. Multicenter short term assessment of patients undergoing the tension free vaginal tape-secur system for the surgical treatment of stress urinary incontinence. J Pelv Med Surg 2007;13(5): Neuman M. TVT-Secur: 100 teaching operations with a novel anti-incontinence procedure. Pelviperineology 2007;26: Masata J, Martan A, Kamil S. Severe bleeding from internal obturator muscle following tension-free vaginal tape Secur hammock approach procedure. Int Urogynecol J 2008;19: Moore RD, Miklos JR. Mini-sling: new minimally invasive one-incision sling for treatment of female stress urinary incontinence. US Obst Gynecol 2008;3(1):

One Slim Needle One Incision. One Simple Solution for Stress Urinary Incontinence. The Difference is in the Data

One Slim Needle One Incision. One Simple Solution for Stress Urinary Incontinence. The Difference is in the Data CONTINENCE SOLUTIONS One Slim Needle One Incision ordering information Description US International Order Number Order Number One Simple Solution for Stress Urinary Incontinence MiniArc Single-Incision

More information

New Insights in the Surgical Management of Stress Urinary Incontinence in Women

New Insights in the Surgical Management of Stress Urinary Incontinence in Women New Insights in the Surgical Management of Stress Urinary Incontinence in Women Gabriel Gillon MD Dept. of Urology Rabin Med. Cent. /Beilinson Incontinence and LUTS 25/6/2009 Symposium Ramat Aviv New Insights

More information

Efficacy and Adverse Effects of Monarc Versus Tension-free Vaginal Tape Obturator: a Retrospective One-year Follow-up Study

Efficacy and Adverse Effects of Monarc Versus Tension-free Vaginal Tape Obturator: a Retrospective One-year Follow-up Study Efficacy and Adverse Effects of Monarc Versus Tension-free Vaginal Tape Obturator: a Retrospective One-year Follow-up Study Yvonne KY CHENG MBChB, MRCOG William WK TO MBBS, M Phil, FRCOG, FHKAM (O&G) HX

More information

This information is intended as an overview only

This information is intended as an overview only This information is intended as an overview only Please refer to the INSTRUCTIONS FOR USE included with this device for indications, contraindications, warnings, precautions and other important information

More information

Minimally invasive treatment for female stress urinary incontinence

Minimally invasive treatment for female stress urinary incontinence Minimally invasive treatment for female stress urinary incontinence Expert Rev. Obstet. Gynecol. 3(2), 257 272 (2008) Robert D Moore, Scott R Serels and G Willy Davila Author for correspondence Atlanta

More information

UroToday International Journal. Volume 4 - February 2011

UroToday International Journal.  Volume 4 - February 2011 UroToday International Journal Scott Serels, 1 Sandy B Nosseir, 2 Lawrence R Lind, 2 Harvey A Winkler 2 1 Bladder Control Center of Norwalk and Section of Urogynecology, Norwalk Hospital, Norwalk, CT,

More information

Efficacy and Safety of the TVT-SECUR R and Impact on Quality of Life in Women with Stress Urinary Incontinence: A 2-Year Follow-Up

Efficacy and Safety of the TVT-SECUR R and Impact on Quality of Life in Women with Stress Urinary Incontinence: A 2-Year Follow-Up www.kjurology.org DOI:10.4111/kju.2011.52.5.335 Voiding Dysfunction Efficacy and Safety of the TVT-SECUR R and Impact on Quality of Life in Women with Stress Urinary Incontinence: A 2-Year Follow-Up Yu

More information

Operative Approach to Stress Incontinence. Goals of presentation. Preoperative evaluation: Urodynamic Testing? Michelle Y. Morrill, M.D.

Operative Approach to Stress Incontinence. Goals of presentation. Preoperative evaluation: Urodynamic Testing? Michelle Y. Morrill, M.D. Operative Approach to Stress Incontinence Goals of presentation Michelle Y. Morrill, M.D. Director of Urogynecology The Permanente Medical Group Kaiser, San Francisco Review preoperative care & evaluation

More information

Interventional procedures guidance Published: 12 October 2016 nice.org.uk/guidance/ipg566

Interventional procedures guidance Published: 12 October 2016 nice.org.uk/guidance/ipg566 Single-incision short sling mesh insertion for stress urinary incontinence in women Interventional procedures guidance Published: 12 October 2016 nice.org.uk/guidance/ipg566 Your responsibility This guidance

More information

of UROLOGY Official Journal of the American Urological Association vwvw.jurology.com

of UROLOGY Official Journal of the American Urological Association vwvw.jurology.com Reprinted from THE JOURNAL of UROLOGY Official Journal of the American Urological Association vwvw.jurology.com Prospective Evaluation of a Single Incision Sling for Stress Urinary Incontinence Michael

More information

Trans-Obturator Tape Operation Using MONARC Technique (Outside-In Technique) --- Revisited Objective and Subjective Assessment

Trans-Obturator Tape Operation Using MONARC Technique (Outside-In Technique) --- Revisited Objective and Subjective Assessment IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 15, Issue 8 Ver. I (August. 2016), PP 58-68 www.iosrjournals.org Trans-Obturator Tape Operation Using

More information

TVT-O versus Monarc after a 2 4-year follow-up: a prospective comparative study

TVT-O versus Monarc after a 2 4-year follow-up: a prospective comparative study Int Urogynecol J (2009) 20:1327 1333 DOI 10.1007/s00192-009-0943-5 ORIGINAL ARTICLE TVT-O versus Monarc after a 2 4-year follow-up: a prospective comparative study R. Marijn Houwert & Charlotte Renes-Zijl

More information

International Federation of Gynecology and Obstetrics

International Federation of Gynecology and Obstetrics International Federation of Gynecology and Obstetrics COMMITTEE FOR UROGYNAECOLOGY AND PELVIC FLOOR MEMBER: TSUNG-HSIEN (CHARLES) SU, CHAIR (TAIWAN) DAVID RICHMOND, CO-CHAIR (UK) CHITTARANJAN PURANDARE,

More information

Sdefined as involuntary urine leakage

Sdefined as involuntary urine leakage Transobturator Tape and Female Urinary Incontinence, Follow up and Complication Swapnil Mane*, Sindhu Chandra** Abstract Stress urinary incontinence (SUI) is defined as involuntary urine leakage on exertion.

More information

The Safety and Efficacy of a New Adjustable Single Incision Sling for Treatment of Female. Stress Urinary Incontinence Through 12-months of Follow-up

The Safety and Efficacy of a New Adjustable Single Incision Sling for Treatment of Female. Stress Urinary Incontinence Through 12-months of Follow-up Manuscript (Submit in MS Word; include Title Page and Abstract; Tables and Figures should NOT be included but attached separately) Runninghead: ALTIS SINGLE INCISION SLING The Safety and Efficacy of a

More information

Treatment of Female Stress Urinary Incontinence by Trans-Obturaror Tension-Free Vaginal Tape (TVT-O): A Prospecive Controlled Study

Treatment of Female Stress Urinary Incontinence by Trans-Obturaror Tension-Free Vaginal Tape (TVT-O): A Prospecive Controlled Study Med. J. Cairo Univ., Vol. 79, No. 1, June: 267-272, 2011 www.medicaljournalofcairouniversity.com Treatment of Female Stress Urinary Incontinence by Trans-Obturaror Tension-Free Vaginal Tape (TVT-O): A

More information

UroToday International Journal. Volume 4 - June 2011

UroToday International Journal.  Volume 4 - June 2011 UroToday International Journal Paulo Palma, 1 Cassio Riccetto, 1 Rodrigo Castro, 2 Sebastian Altuna, 3 Viviane Herrmann, 1 Ricardo Miyaoka 1 1 Division of Female Urology, State University of Campinas (UNICAMP),

More information

Complications Following Outside-in and Inside-out Transobturator-Tape Procedures with Concomitant Gynecologic Operations

Complications Following Outside-in and Inside-out Transobturator-Tape Procedures with Concomitant Gynecologic Operations Original Article-Surgery www.cmj.ac.kr Complications Following Outside-in and Inside-out Transobturator-Tape Procedures with Concomitant Gynecologic Operations Moon Kyoung Cho, Chul Hong Kim*, Woo Dae

More information

Treatment Outcomes of Tension-free Vaginal Tape Insertion

Treatment Outcomes of Tension-free Vaginal Tape Insertion Are the Treatment Outcomes of Tension-free Vaginal Tape Insertion the Same for Patients with Stress Urinary Incontinence with or without Intrinsic Sphincter Deficiency? A Retrospective Study in Hong Kong

More information

q7:480499_P0 6/5/09 10:23 AM Page 1 WHAT YOU SHOULD KNOW ABOUT YOUR DIAGNOSIS OF STRESS URINARY INCONTINENCE

q7:480499_P0 6/5/09 10:23 AM Page 1 WHAT YOU SHOULD KNOW ABOUT YOUR DIAGNOSIS OF STRESS URINARY INCONTINENCE 493495.q7:480499_P0 6/5/09 10:23 AM Page 1 WHAT YOU SHOULD KNOW ABOUT YOUR DIAGNOSIS OF STRESS URINARY INCONTINENCE 493495.q7:480499_P0 6/5/09 10:23 AM Page 2 What is Stress Urinary Incontinence? Urinary

More information

A PATIENT GUIDE TO Understanding Stress Urinary Incontinence

A PATIENT GUIDE TO Understanding Stress Urinary Incontinence A PATIENT GUIDE TO Understanding Stress Urinary Incontinence Q: What is SUI? A: Stress urinary incontinence is defined as the involuntary leakage of urine. The problem afflicts approximately 18 million

More information

Resolution of urge urinary incontinence with midurethral sling surgery in patients with mixed incontinence and low-pressure urethra

Resolution of urge urinary incontinence with midurethral sling surgery in patients with mixed incontinence and low-pressure urethra Gynecol Surg (2012) 9:427 432 DOI 10.1007/s10397-012-0735-7 ORIGINAL ARTICLE Resolution of urge urinary incontinence with midurethral sling surgery in patients with mixed incontinence and low-pressure

More information

Midterm Prospective Evaluation of TVT-Secur Reveals High Failure Rate

Midterm Prospective Evaluation of TVT-Secur Reveals High Failure Rate EUROPEAN UROLOGY 58 (2010) 157 161 available at www.sciencedirect.com journal homepage: www.europeanurology.com Female Urology Incontinence Midterm Prospective Evaluation of TVT-Secur Reveals High Failure

More information

Voiding Dysfunction. Yoo Jun Park, Duk Yoon Kim. INTRODUCTION

Voiding Dysfunction. Yoo Jun Park, Duk Yoon Kim.   INTRODUCTION www.kjurology.org http://dx.doi.org/10.4111/kju.2012.53.4.258 Voiding Dysfunction Randomized Controlled Study of R vs. Tension-free Vaginal Tape Obturator ( R ) in the Treatment of Female Urinary Incontinence:

More information

Tension-free Vaginal Tape for Urodynamic Stress Incontinence

Tension-free Vaginal Tape for Urodynamic Stress Incontinence Long-term Results of Tension-free Vaginal Tape Insertion for Urodynamic Stress Incontinence in Chinese Women at Eight-year Follow-up: a Prospective Study YM CHAN MBBS, MRCOG, FHKAM (O&G), DCG, DCH, DFM,

More information

Urethrolysis; When, Why & How. M Karram Professor of Ob/Gyn & Urology University of Cincinnati

Urethrolysis; When, Why & How. M Karram Professor of Ob/Gyn & Urology University of Cincinnati Urethrolysis; When, Why & How M Karram Professor of Ob/Gyn & Urology University of Cincinnati Anatomy Urethra may be fixed to the pubic bone with dense scar tissue Goal of urethrolysis is to completely

More information

Desara and Desara Blue

Desara and Desara Blue Desara and Desara Blue Sling for Female Stress Urinary Incontinence Instructions For Use D I Prescription Use only Do not reuse Sterilized using ethylene oxide M Manufactured by: Caldera Medical, Inc.

More information

Nine-year experience in sub-urethral prosthesis for the treatment of female stress urinary incontinence

Nine-year experience in sub-urethral prosthesis for the treatment of female stress urinary incontinence Nine-year experience in sub-urethral prosthesis for the treatment of female stress urinary incontinence Adrian Haşegan Department of Urology, Emergency County Hospital Sibiu, Faculty of Medicine Abstract

More information

I-STOP TOMS Transobturator Male Sling

I-STOP TOMS Transobturator Male Sling I-STOP TOMS Transobturator Male Sling The CL Medical I-STOP TOMS sling for male stress urinary incontinence was developed in France where it is widely used and is the market leader. It is constructed with

More information

Outpatient mid-urethral tissue fixation system sling for urodynamic stress urinary incontinence: 3-year surgical and quality of life results

Outpatient mid-urethral tissue fixation system sling for urodynamic stress urinary incontinence: 3-year surgical and quality of life results Int Urogynecol J (2017) 28:1733 1738 DOI 10.1007/s00192-017-3341-4 ORIGINAL ARTICLE Outpatient mid-urethral tissue fixation system sling for urodynamic stress urinary incontinence: 3-year surgical and

More information

Transobturator tension free vaginal tapes: Are they the way forward in the surgical treatment of urodynamic stress incontinence?

Transobturator tension free vaginal tapes: Are they the way forward in the surgical treatment of urodynamic stress incontinence? International Journal of Surgery (2007) 5, 3e10 www.theijs.com Transobturator tension free vaginal tapes: Are they the way forward in the surgical treatment of urodynamic stress incontinence? M. Abdel-fattah*,

More information

Gert Naumann Joscha Steetskamp Mira Meyer Rosa Laterza Christine Skala Stefan Albrich Heinz Koelbl

Gert Naumann Joscha Steetskamp Mira Meyer Rosa Laterza Christine Skala Stefan Albrich Heinz Koelbl DOI 10.1007/s00404-012-2669-8 GENERAL GYNECOLOGY Sexual function and quality of life following retropubic TVT and single-incision sling in women with stress urinary incontinence: results of a prospective

More information

Stress Urinary Incontinence Surgery with Mini Sling Just-Swing System: Our Office Experience

Stress Urinary Incontinence Surgery with Mini Sling Just-Swing System: Our Office Experience Journal of Women s Health and Gynecology Review Stress Urinary Incontinence Surgery with Mini Sling Just-Swing System: Our Office Experience Ana Ribeiro *, Maria Boia, Ana Cláudia Santos, Isabel Ferreira,

More information

Effect of Anesthesia on Voiding Function After Tension-Free Vaginal Tape Procedure

Effect of Anesthesia on Voiding Function After Tension-Free Vaginal Tape Procedure Effect of Anesthesia on Voiding Function After Tension-Free Vaginal Tape Procedure M. Murphy, MD, M. H. Heit, MD, MSPH, L. Fouts, MD, C. A. Graham, MD, L. Blackwell, RN, and P. J. Culligan, MD OBJECTIVE:

More information

Pelvic artery embolization in the management of pelvic arterial bleeding following midurethral sling surgery for stress urinary incontinence

Pelvic artery embolization in the management of pelvic arterial bleeding following midurethral sling surgery for stress urinary incontinence Case Report Obstet Gynecol Sci 2016;59(2):163-167 http://dx.doi.org/10.5468/ogs.2016.59.2.163 pissn 2287-8572 eissn 2287-8580 Pelvic artery embolization in the management of pelvic arterial bleeding following

More information

LONG TERM FOLLOW UP OF THE TRANSOBTURATOR TAPE PROCEDURE FOR THE TREATMENT OF STRESS URINARY INCONTINENCE IN A TERTIARY HOSPITAL IN SOUTH AFRICA

LONG TERM FOLLOW UP OF THE TRANSOBTURATOR TAPE PROCEDURE FOR THE TREATMENT OF STRESS URINARY INCONTINENCE IN A TERTIARY HOSPITAL IN SOUTH AFRICA LONG TERM FOLLOW UP OF THE TRANSOBTURATOR TAPE PROCEDURE FOR THE TREATMENT OF STRESS URINARY INCONTINENCE IN A TERTIARY HOSPITAL IN SOUTH AFRICA Dr. A. Chrysostomou MD, FCOG (SA), Mmed (WITS) Senior Specialist,

More information

Desara Blue OV D I. Sling for Female Stress Urinary Incontinence. Instructions For Use

Desara Blue OV D I. Sling for Female Stress Urinary Incontinence. Instructions For Use Desara Blue OV Sling for Female Stress Urinary Incontinence Instructions For Use D I Prescription Use only Do not reuse Sterilized using ethylene oxide M Manufactured by: Caldera Medical, Inc. 5171 Clareton

More information

Stress Urinary Incontinence in Women. What YOU can do about it...

Stress Urinary Incontinence in Women. What YOU can do about it... Stress Urinary Incontinence in Women What YOU can do about it... www.gynecare.com Stress Urinary Incontinence in Women: It's Common. It's Treatable. Would it surprise you... To learn that more than 13

More information

Only 15 years ago, when surgery was

Only 15 years ago, when surgery was Almost all surgical procedures for stress urinary incontinence performed today involve placement of a retropubic or transobturator midurethral synthetic sling. 28 OBG Management March May 2012 2010 Vol.

More information

Predictors of Postoperative Voiding Dysfunction following Transobsturator Sling Procedures in Patients with Stress Urinary Incontinence

Predictors of Postoperative Voiding Dysfunction following Transobsturator Sling Procedures in Patients with Stress Urinary Incontinence Voiding Dysfunction INJ 2010;14:26-33 Predictors of Postoperative Voiding Dysfunction following Transobsturator Sling Procedures in Patients with Stress Urinary Incontinence Sung-Tae Cho, Hyeong-Cheol

More information

Contasure-Needleless single incision sling compared with transobturator TVT-O for the treatment of stress urinary incontinence: long-term results

Contasure-Needleless single incision sling compared with transobturator TVT-O for the treatment of stress urinary incontinence: long-term results IntUrogynecolJ DOI 10.1007/s00192-014-2475-x ORIGINAL ARTICLE Contasure-Needleless single incision sling compared with transobturator TVT-O for the treatment of stress urinary incontinence: long-term results

More information

Blue Ridge Urogynecology

Blue Ridge Urogynecology Surgery for Stress Urinary Incontinence Surgery has proved to be a very effective treatment for stress incontinence. The best surgical procedures improve or cure the incontinence in 85 to 90 percent of

More information

Int Urogynecol J (2010) 21: DOI /s ORIGINAL ARTICLE Experience with TVT-SECUR sling for stress urinary incontinence: a 1

Int Urogynecol J (2010) 21: DOI /s ORIGINAL ARTICLE Experience with TVT-SECUR sling for stress urinary incontinence: a 1 Int Urogynecol J (2010) 21:767 772 DOI 10.1007/s00192-010-1114-4 ORIGINAL ARTICLE Experience with TVT-SECUR sling for stress urinary incontinence: a 141-case analysis Salil Khandwala & Chaandini Jayachandran

More information

Current trend in anti-incontinence surgery

Current trend in anti-incontinence surgery Current trend in anti-incontinence surgery 吳銘斌醫師 (Ming-Ping Wu, M.D., Ph.D.) 奇美醫院婦產部婦女泌尿暨骨盆醫學科主任台北醫學大學醫學院婦產學科副教授成功大學醫學院臨床醫學所博士 Anti-incontinence surgery Bladder buttress operation: Kelly plication Needle

More information

Sep \8958 Appell Dmochowski.ppt LMF 1

Sep \8958 Appell Dmochowski.ppt LMF 1 Surgical Outcomes (How did we get ourselves into this mess?) Roger R. Dmochowski, MD, FACS Department of Urologic Surgery Vanderbilt University School of Medicine Nashville, Tennessee Considerations Evaluation

More information

Objective and Subjective Cure Rates after Trans-Obturator Tape (OBTAPE 1 ) Treatment of Female Urinary Incontinence

Objective and Subjective Cure Rates after Trans-Obturator Tape (OBTAPE 1 ) Treatment of Female Urinary Incontinence european urology 49 (2006) 373 377 available at www.sciencedirect.com journal homepage: www.europeanurology.com Female Urology Objective and Subjective Cure Rates after Trans-Obturator Tape (OBTAPE 1 )

More information

Transobturator Tape in Treatment of Stress Urinary Incontinence: It is Time for a New Gold Standard

Transobturator Tape in Treatment of Stress Urinary Incontinence: It is Time for a New Gold Standard Original Article Transobturator Tape in Treatment of Stress Urinary Incontinence: It is Time for a New Gold Standard Navneet Magon, Sanjiv Chopra VSM 1 Department of Gynecology and Obstetrics, Air Force

More information

Department of Obstetrics and Gynecology, Faculty of Medicine, Minia University, Minia, Egypt

Department of Obstetrics and Gynecology, Faculty of Medicine, Minia University, Minia, Egypt Original Article The role of trans-obturator vaginal tape (TVT-O) in the management of female stress urinary incontinence: 2 years follow up, Minia University Experience Ahmed M. Abdel ghany Department

More information

Seventeen years follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence

Seventeen years follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence Int Urogynecol J (2013) 24:1265 1269 DOI 10.1007/s00192-013-2090-2 ORIGINAL ARTICLE: EDITORS CHOICE Seventeen years follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence

More information

Current Role of Urethrolysis and Partial Excision in Patients Seeking Revision of Anti-Incontinence Sling

Current Role of Urethrolysis and Partial Excision in Patients Seeking Revision of Anti-Incontinence Sling ORIGINAL ARTICLE Current Role of Urethrolysis and Partial Excision in Patients Seeking Revision of Anti-Incontinence Sling Alice Drain, MD,* Ekene Enemchukwu, MD, MPH, Nihar Shah, BA,* Raveen Syan, MD,*

More information

Curr Opin Obstet Gynecol 21: ß 2009 Wolters Kluwer Health Lippincott Williams & Wilkins X

Curr Opin Obstet Gynecol 21: ß 2009 Wolters Kluwer Health Lippincott Williams & Wilkins X Comparison of tension-free vaginal tape and transobturator tape procedure for the treatment of stress urinary incontinence Cheng-Yu Long a,b, Chun-Shuo Hsu c, Ming-Ping Wu d, Cheng-Min Liu a, Tsu-Nai Wang

More information

Incidence and Risk Factors of Postoperative De Novo Voiding Dysfunction following Midurethral Sling Procedures

Incidence and Risk Factors of Postoperative De Novo Voiding Dysfunction following Midurethral Sling Procedures Incidence and Risk Factors of Postoperative De Novo Voiding Dysfunction following Midurethral Sling Procedures Hoon Ah Jang, Jae Hyun Bae, Jeong Gu Lee From the Department of Urology, College of Medicine,

More information

Women with intrinsic sphincter deficiency associated

Women with intrinsic sphincter deficiency associated Three-Year Follow-Up of Tension-Free Vaginal Tape Compared With Transobturator Tape in Women With Stress Urinary Incontinence and Intrinsic Sphincter Deficiency Lore Schierlitz, FRANZCOG, Peter L. Dwyer,

More information

SPARC Sling System for Treatment of Female Stress Urinary Incontinence in the Elderly

SPARC Sling System for Treatment of Female Stress Urinary Incontinence in the Elderly european urology 50 (2006) 826 831 available at www.sciencedirect.com journal homepage: www.europeanurology.com Female Urology Incontinence SPARC Sling System for Treatment of Female Stress Urinary Incontinence

More information

Repeat midurethral sling treatment for prior midurethral sling failure

Repeat midurethral sling treatment for prior midurethral sling failure Gynecol Surg (2012) 9:17 21 DOI 10.1007/s10397-011-0675-7 REVIEW ARTICLE Repeat midurethral sling treatment for prior midurethral sling failure Chi-Feng Su & Kwong-Pang Tsui & Horng-Jyh Tsai & Gin-Den

More information

Desara TV and Desara Blue TV

Desara TV and Desara Blue TV Desara TV and Desara Blue TV Sling for Female Stress Urinary Incontinence Instructions For Use D I Prescription Use only Do not reuse Sterilized using ethylene oxide Available Electronically M Manufactured

More information

Tension-Free Vaginal Tape Versus Transobturator Suburethral Tape: Five-Year Follow-up Results of a Prospective, Randomised Trial

Tension-Free Vaginal Tape Versus Transobturator Suburethral Tape: Five-Year Follow-up Results of a Prospective, Randomised Trial EUROPEAN UROLOGY 58 (2010) 671 677 available at www.sciencedirect.com journal homepage: www.europeanurology.com Platinum Priority Female Urology Incontinence Editorial by Elisabetta Costantini and Massimo

More information

Stress urinary incontinence (SUI) is the urine leakage

Stress urinary incontinence (SUI) is the urine leakage FEMALE UROLOGY Comparison of Transobturator Tape Surgery Using Commercial and Hand Made Slings in Women with Stress Urinary Incontinence Seyfettin Ciftci, 1 * Cuneyd Ozkurkcugil, 1 Murat Ustuner, 1 Hasan

More information

Tension free vaginal tape Transe obturator tape

Tension free vaginal tape Transe obturator tape Tension free vaginal tape Transe obturator tape * Tension free"#! 7*-R7#k>$&>C.? /& #n [m -4>i. C l,m MTOTL 7 FoNC&sling$,2?7 >6$8,.$F" 7/#.Tension Free (TVT) c.pla6

More information

Medical Policy Title: Radiofrequency ARBenefits Approval: 10/19/2011

Medical Policy Title: Radiofrequency ARBenefits Approval: 10/19/2011 Medical Policy Title: Radiofrequency ARBenefits Approval: 10/19/2011 Treatment, Urinary Stress Incontinence, Transurethral Effective Date: 01/01/2012 Document: ARB0359 Revision Date: Code(s): 53860 Transurethral

More information

How to Achieve Long-Term Success in the Treatment of Female Urinary Stress Incontinence? Novel Modification on Vaginal Sling

How to Achieve Long-Term Success in the Treatment of Female Urinary Stress Incontinence? Novel Modification on Vaginal Sling www.kjurology.org DOI:10.4111/kju.2011.52.3.184 Voiding Dysfunction How to Achieve Long-Term Success in the Treatment of Female Urinary Stress Incontinence? Novel Modification on Vaginal Sling Mahmoud

More information

Elsevier Editorial System(tm) for Journal de Gynécologie Obstétrique et Biologie de la Reproduction Manuscript Draft

Elsevier Editorial System(tm) for Journal de Gynécologie Obstétrique et Biologie de la Reproduction Manuscript Draft Elsevier Editorial System(tm) for Journal de Gynécologie Obstétrique et Biologie de la Reproduction Manuscript Draft Manuscript Number: JGYN-D-16-00250R1 Title: Vaginocutaneous fistula and buttock abscess

More information

Tension-Free Vaginal Taping in Pakistani Women with Stress Urinary Incontinence

Tension-Free Vaginal Taping in Pakistani Women with Stress Urinary Incontinence ORIGINAL ARTICLE Tension-Free Vaginal Taping in Pakistani Women with Stress Urinary Incontinence Ayesha Saleem ABSTRACT Objective: To evaluate the effectiveness and determine the peroperative and postoperative

More information

Sarah A. Huber, 1 LaChanda Dunlap-Wright, 2 John R. Miklos, 1 and Robert D. Moore Introduction

Sarah A. Huber, 1 LaChanda Dunlap-Wright, 2 John R. Miklos, 1 and Robert D. Moore Introduction Case Reports in Urology Volume 2016, Article ID 6180756, 5 pages http://dx.doi.org/10.1155/2016/6180756 Case Report Concomitant Laparoscopic Burch Urethropexy and Combined Vaginal-Laparoscopic Mesh Sling

More information

PUBOVAGINAL SLING IN THE TREATMENT OF STRESS URINARY INCONTINENCE FOR URETHRAL HYPERMOBILITY AND INTRINSIC SPHINCTERIC DEFICIENCY

PUBOVAGINAL SLING IN THE TREATMENT OF STRESS URINARY INCONTINENCE FOR URETHRAL HYPERMOBILITY AND INTRINSIC SPHINCTERIC DEFICIENCY Urological Neurology International Braz J Urol Official Journal of the Brazilian Society of Urology PUBOVAGINAL SLING IN SUI Vol. 29 (6): 540-544, November - December, 2003 PUBOVAGINAL SLING IN THE TREATMENT

More information

To compare intermittent catheterization, sling mobilization and sling transection for treatment of

To compare intermittent catheterization, sling mobilization and sling transection for treatment of 1 ABSTRACT: Objective: To compare intermittent catheterization, sling mobilization and sling transection for treatment of urinary retention after mid-urethral sling surgery. Methods: Data registered in

More information

Risk Factors of Voiding Dysfunction and Patient Satisfaction After Tension-free Vaginal Tape Procedure

Risk Factors of Voiding Dysfunction and Patient Satisfaction After Tension-free Vaginal Tape Procedure J Korean Med Sci 2005; 20: 1006-10 ISSN 1011-8934 Copyright The Korean Academy of Medical Sciences Risk Factors of Voiding Dysfunction and Patient Satisfaction After Tension-free Vaginal Tape Procedure

More information

Surgical management of stress urinary incontinence in Scotland and Wales: A questionnaire study

Surgical management of stress urinary incontinence in Scotland and Wales: A questionnaire study International Journal of Surgery (2007) 5, 162e166 www.theijs.com Surgical management of stress urinary incontinence in Scotland and Wales: A questionnaire study Min Yu Lim a, *, Mahesh Perera b, Ian Ramsay

More information

Female Urology Evaluation of Transobturator Tension-free Vaginal Tapes in Management of Women With Recurrent Stress Urinary Incontinence

Female Urology Evaluation of Transobturator Tension-free Vaginal Tapes in Management of Women With Recurrent Stress Urinary Incontinence Female Urology Evaluation of Transobturator Tension-free Vaginal Tapes in Management of Women With Recurrent Stress Urinary Incontinence Mohamed Abdel-Fattah, Ian Ramsay, Stewart Pringle, Chris Hardwick,

More information

Long-Term Durability of the Distal Urethral Polypropylene Sling for the Treatment of Stress Urinary Incontinence: Minimum 11-Year Followup

Long-Term Durability of the Distal Urethral Polypropylene Sling for the Treatment of Stress Urinary Incontinence: Minimum 11-Year Followup Long-Term Durability of the Distal Urethral Polypropylene Sling for the Treatment of Stress Urinary Incontinence: Minimum 11-Year Followup Lisa Rogo-Gupta,*, Z. Chad Baxter, Ngoc-Bich Le, Shlomo Raz and

More information

Leiden University Medical Center, Department of Urology, 2300 RC Leiden, the Netherlands.

Leiden University Medical Center, Department of Urology, 2300 RC Leiden, the Netherlands. FVV in ObGyn, 2013, 5 (4): 249-253 Original paper A novel radiographic technique to asses grafts in the female pelvis: a comparison of the Inside-Out and the Outside-In transobturator mid urethral sling

More information

UroToday International Journal. Volume 3 - October 2010

UroToday International Journal.  Volume 3 - October 2010 UroToday International Journal Osama Abdelwahab, Hammouda Sherif Department of Urology, Faculty of Medicine, Benha University, Benha, Egypt Submitted August 18, 2010 - Accepted for Publication September

More information

Overactive bladder symptoms after midurethral sling surgery in women: Risk factors and management

Overactive bladder symptoms after midurethral sling surgery in women: Risk factors and management Received: 4 January 2017 Accepted: 2 May 2017 DOI: 10.1002/nau.23328 REVIEW ARTICLE Overactive bladder symptoms after midurethral sling surgery in women: Risk factors and management Tom Marcelissen Philip

More information

Intraoperative Observation of the Degree and Pattern of Urine Leakage before Adjustment of the Mesh during a Transobturator Tape Procedure

Intraoperative Observation of the Degree and Pattern of Urine Leakage before Adjustment of the Mesh during a Transobturator Tape Procedure Original Article www.cmj.ac.kr Intraoperative Observation of the Degree and Pattern of Urine Leakage before Adjustment of the Mesh during a Transobturator Tape Procedure Jae-Joon Park, Hyung Ho Lee 1 and

More information

european urology 51 (2007)

european urology 51 (2007) european urology 51 (2007) 1376 1384 available at www.sciencedirect.com journal homepage: www.europeanurology.com Female Urology Incontinence One-Year Follow-up of Tension-free Vaginal Tape (TVT) and Trans-obturator

More information

Evaluation of the Outcome of Transobturator Vaginal Tape in Management of Stress Incontinence in Women. H.S. Mohamed

Evaluation of the Outcome of Transobturator Vaginal Tape in Management of Stress Incontinence in Women. H.S. Mohamed Evaluation of the Outcome of Transobturator Vaginal Tape in Management of Stress Incontinence in Women H.S. Mohamed Obstetrics and Gynecology, Woman's Health University Centre, Assiut University, 5 th

More information

Suburethral slingplasty evaluation study in North Queensland, Australia: The SUSPEND trial

Suburethral slingplasty evaluation study in North Queensland, Australia: The SUSPEND trial Australian and New Zealand Journal of Obstetrics and Gynaecology 2005; 45: 52 59 Blackwell Publishing, Ltd. Original Article The SUSPEND trial Suburethral slingplasty evaluation study in North Queensland,

More information

Anatomical and Functional Results of Pelvic Organ Prolapse Mesh Repair: A Prospective Study of 105 Cases

Anatomical and Functional Results of Pelvic Organ Prolapse Mesh Repair: A Prospective Study of 105 Cases International Journal of Clinical Urology 2018; 2(1): 20-24 http://www.sciencepublishinggroup.com/j/ijcu doi: 10.11648/j.ijcu.20180201.14 Anatomical and Functional Results of Pelvic Organ Prolapse Mesh

More information

Midurethral Slings for Women with Stress Urinary Incontinence

Midurethral Slings for Women with Stress Urinary Incontinence Ontario Health Technology Assessment Series 2006; Vol. 6, No. 3 Midurethral Slings for Women with Stress Urinary Incontinence An Evidence Based Analysis February 2006 Medical Advisory Secretariat Ministry

More information

Surgical Outcomes after Distal Suburethral Sling Procedures for Stress Urinary Incontinence in Aged Patients

Surgical Outcomes after Distal Suburethral Sling Procedures for Stress Urinary Incontinence in Aged Patients Surgical Outcomes after Distal Suburethral Sling Procedures for Stress Urinary Incontinence in Aged Patients Won Seok Sim, Kwang Yeom Lee, Khae Hawn Kim, Han Jung, Sang Jin Yoon From the Department of

More information

TVT-O for the Treatment of Female Stress Urinary Incontinence: Results of a Prospective Study after a 3-Year Minimum Follow-Up

TVT-O for the Treatment of Female Stress Urinary Incontinence: Results of a Prospective Study after a 3-Year Minimum Follow-Up european urology 53 (2008) 401 410 available at www.sciencedirect.com journal homepage: www.europeanurology.com Female Urology Incontinence TVT-O for the Treatment of Female Stress Urinary Incontinence:

More information

Influence of Obesity on Short-term Surgical Outcome of the Transobturator Tape Procedure in Patients with Stress Urinary Incontinence

Influence of Obesity on Short-term Surgical Outcome of the Transobturator Tape Procedure in Patients with Stress Urinary Incontinence Urinary Incontinence INJ 2010;14:13-19 Influence of Obesity on Short-term Surgical Outcome of the Transobturator Tape Procedure in Patients with Stress Urinary Incontinence Dong-Un Tchey, Won-Tae Kim,

More information

ORIGINAL ARTICLE. Elaine Church & Lenzi Hanna. Introduction

ORIGINAL ARTICLE. Elaine Church & Lenzi Hanna. Introduction Gynecol Surg (2010) 7:31 37 DOI 10.1007/s10397-009-0532-0 ORIGINAL ARTICLE Safety and efficacy of the transobturator tape for stress urinary incontinence: short-term and medium-term results of 125 patients

More information

Innovations in mesh kit technology for vaginal wall prolapse

Innovations in mesh kit technology for vaginal wall prolapse Available at www.obgmanagement.com s u p p l e m e n t t o This supplement is supported by American Medical Systems, Inc., and has been peer reviewed by the editors of OBG Management. J a n u a r y 2 0

More information

Key Words: urinary incontinence, suburethral slings

Key Words: urinary incontinence, suburethral slings Evaluation of Transobturator Tension-Free Vaginal Tapes in the Surgical Management of Mixed Urinary Incontinence: 3-Year Outcomes of a Randomized Controlled Trial Mohamed Abdel-Fattah,*, Laura R. Hopper

More information

What you should know about your diagnosis of incontinence

What you should know about your diagnosis of incontinence What you should know about your diagnosis of incontinence What is Stress Urinary Incontinence? WHAT IS NORMAL URINARY FUNCTION? Urine is a normal waste product of the body that is manufactured by the kidneys

More information

When the suburethral sling was first

When the suburethral sling was first SURGICAL TECHNIQUES BY CHERYL IGLESIA, MD, AND MARIA PETTIT CANTER, MD Treating stress urinary incontinence with suburethral slings Recent modifications to suburethral sling procedures have brought them

More information

Stress Urinary Incontinence in Women

Stress Urinary Incontinence in Women Stress Urinary Incontinence in Women Stress Urinary Incontinence in Women: It's Common. It's Treatable. Would it surprise you... To learn that more than 3 million women in the United Kingdom have urinary

More information

Paravaginal Repair: A Laparoscopic Approach

Paravaginal Repair: A Laparoscopic Approach 44 Paravaginal Repair: A Laparoscopic Approach John R. Miklos and Robert Moore Atlanta Urogynecology Associates, Atlanta, Georgia, U.S.A. Neeraj Kohli Harvard University, Boston, Massachusetts, U.S.A.

More information

Medical Review Criteria Invasive Treatment for Urinary Incontinence

Medical Review Criteria Invasive Treatment for Urinary Incontinence Medical Review Criteria Invasive Treatment for Urinary Incontinence Effective Date: December 21, 2016 Subject: Invasive Treatment for Urinary Incontinence Background: Urinary incontinence (the involuntary

More information

Department of Obstetrics and Gynecology, Istanbul Bakirkoy Women and Childrens Hospital, İstanbul, Turkey

Department of Obstetrics and Gynecology, Istanbul Bakirkoy Women and Childrens Hospital, İstanbul, Turkey Acta Obstetricia et Gynecologica. 2009; 88: 920926 ORIGINAL ARTICLE Which type of mid-urethral sling procedure should be chosen for treatment of stress urinary incontinance with intrinsic sphincter deficiency?

More information

EFFICIENCY OF TREATMENT FOR FEMALE SUI (STRESS URINARY INCONTINENCE) USING THE TVT-O (TENSION-FREE VAGINAL TAPE OBTURATOR) TECHNIQUE

EFFICIENCY OF TREATMENT FOR FEMALE SUI (STRESS URINARY INCONTINENCE) USING THE TVT-O (TENSION-FREE VAGINAL TAPE OBTURATOR) TECHNIQUE Rev. Med. Chir. Soc. Med. Nat., Iaşi 2016 vol. 120, no. 3 SURGERY ORIGINAL PAPERS EFFICIENCY OF TREATMENT FOR FEMALE SUI (STRESS URINARY INCONTINENCE) USING THE TVT-O (TENSION-FREE VAGINAL TAPE OBTURATOR)

More information

ANDREAS CHRYSOSTOMOU, HAYLEY JACOBSON, MARIA CHRYSOSTOMOU

ANDREAS CHRYSOSTOMOU, HAYLEY JACOBSON, MARIA CHRYSOSTOMOU Original article An assessment of the functional outcome and quality of life before and after trans-obturator tape surgery for stress urinary incontinence ANDREAS CHRYSOSTOMOU, HAYLEY JACOBSON, MARIA CHRYSOSTOMOU

More information

Another year is drawing to a close

Another year is drawing to a close For mass reproduction, content licensing and permissions contact Dowden Health Media. NEW DEVELOPMENTS THAT ARE CHANGING PATIENT CARE Surgery for stress incontinence A pain drug for OAB? Does genetics

More information

European Urology 46 (2004)

European Urology 46 (2004) European Urology European Urology 46 (2004) 102 107 Surgical Treatment of Female Stress Urinary Incontinence with atrans-obturator-tape (T.O.T. 1 )Uratape 1 :ShortTerm Results of a Prospective Multicentric

More information

Urethral pressure measurement in stress incontinence: does it help?

Urethral pressure measurement in stress incontinence: does it help? Int Urol Nephrol (2009) 41:491 495 DOI 10.1007/s11255-008-9506-9 UROLOGY - ORIGINAL PAPER Urethral pressure measurement in stress incontinence: does it help? Bassem S. Wadie Æ Ahmed S. El-Hefnawy Received:

More information

Clinical Study Cough Test during Tension-Free Vaginal Tape Procedure in Preventing Postoperative Urinary Retention

Clinical Study Cough Test during Tension-Free Vaginal Tape Procedure in Preventing Postoperative Urinary Retention Advances in Urology Volume 2013, Article ID 797854, 4 pages http://dx.doi.org/10.1155/2013/797854 Clinical Study Cough Test during Tension-Free Vaginal Tape Procedure in Preventing Postoperative Urinary

More information

A three-year follow up of tension free vaginal tape for surgical treatment of female stress urinary incontinence

A three-year follow up of tension free vaginal tape for surgical treatment of female stress urinary incontinence British Journal of Obstetrics and Gynaecology April 1999, VO~ 106, pp. 345350 A threeyear follow up of tension free vaginal tape for surgical treatment of female stress urinary incontinence Ulf Ulmsten

More information

Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction

Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction Original Article - Female Urology pissn 2466-0493 eissn 2466-054X Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction

More information

Introital ultrasound in the diagnosis of lower urinary tract symptoms following anti-incontinence surgery using a synthetic midurethral tape

Introital ultrasound in the diagnosis of lower urinary tract symptoms following anti-incontinence surgery using a synthetic midurethral tape International Urogynecology Journal https://doi.org/10.1007/s00192-018-3837-6 ORIGINAL ARTICLE Introital ultrasound in the diagnosis of lower urinary tract symptoms following anti-incontinence surgery