How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained

Size: px
Start display at page:

Download "How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained"

Transcription

1 How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained Poster No.: C-3077 Congress: ECR 2010 Type: Educational Exhibit Topic: Vascular Authors: D. V. Thomas; Northampton/UK Keywords: Zenith Flex stent graft, Planning an EVAR, CT Aortogram DOI: /ecr2010/C-3077 Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not available in the pdf version of presentations. Page 1 of 21

2 Learning objectives To understand the basic concepts and methodology in the planning of a Zenith Flex AAA stent graft from a multi-detector row computed tomography angiogram (CTA) of the abdominal aorta. This is illustrated by an example with appropriate CTA images and calculations according to our departmental Zenith Flex planning sheet. Background Endovascular stent-graft repair (EVAR) of abdominal aortic aneurysms (AAA) is a rapidly growing option in the treatment of AAA. It is important that all interventional radiologists and vascular surgeons who are involved in setting up an EVAR service are familiar with the basic measurements and concepts used to plan an appropriately sized aortic stent graft from a CT angiogram of the aorta. Zenith-Flex is the latest version of the popular stent graft from Cook Ltd. An example is used to illustrate how this graft may be planned from a CTA. Imaging findings OR Procedure details The important points to note when evaluating a CT angiogram for an endovascular stent graft may be grouped as follows Anatomical suitability. Measurements required to plan the graft - This will be covered in this presentation with an example. Presence of other aneurysms. Presence of any other pathology in the abdomen. This presentation is mainly to illustrate the process of planning a Zenith-Flex endovascular AAA stent-graft from the CT angiogram. Evaluation of suitability and other factors or steps of stent deployment are beyond the remit of this presentation. Page 2 of 21

3 Zenith Flex AAA Stent Graft This is a woven polyester graft sutured to a frame of self-expanding stainless steel stents and contained within a delivery system (H&LB One-shot Introduction System). The graft consists of three parts - a main body and two iliac limbs. Another available option is the aorto-uni-iliac graft consisting of a body and a single iliac limb. Page 3 of 21

4 Page 4 of 21

5 Fig.: Main body References: Cook Ltd Iliac limb Page 5 of 21

6 Page 6 of 21

7 Fig.: Iliac Limb References: Cook Ltd Recommended measurements for suitability Fig.: Recommended measurements for suitability References: Cook Ltd Measurements Page 7 of 21

8 The basic measurements are as follows Diameter at the level of the renal arteries - D1 Diameter of the ipsilateral common iliac artery - D2 Diameter of the contralateral common iliac artery - D3 Length from the level of the renal arteries to the aortic bifurcation - L1 Length from the level of the renal arteries to the ipsilateral CIA deployment zone - L2 Length from the level of the renal arteries to the contralateral CIA deployment zone - L3 In addition, the diameter of the external iliac arteries are also calculated to ensure that these are wide enough for the device (>7mm). The measurements should ideally be taken from a good quality CT angiogram. Axial and curved reformat images are used. A curved reformat along the centre-line will take any vessel tortuosity into account as well. The above measurements are then used in the planning sheet and based on these, the appropriate device components can be selected. Note - Ipsilateral - this is usually the right side as the main body is usually deployed up the right side. The left side is therefore Contralateral. Care should be taken to reverse the designation of measurements and plan if the main body is deployed up the left side. Sample plan An example of a plan done for one of our patients recently is as followsd1 - diameter at lowest renal artery = 21mm Page 8 of 21

9 Fig.: D1 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM D2 - diameter at the ipsilateral CIA landing zone (right) = 12mm Page 9 of 21

10 Fig.: D2 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM D3 - diameter at the contralateral CIA landing zone (left)= 13mm Page 10 of 21

11 Fig.: D3 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM L1 - length from lowest renal artery to aortic bifurcation= 128mm Page 11 of 21

12 Page 12 of 21

13 Fig.: L1 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM Ipsilateral - this is usually the right side as the main body is usually deployed up the right side. Care should be taken with planning and the measurements if the main body is deployed up the left side. L2 - length from lowest renal artery to ipsilateral CIA landing zone= 188mm Page 13 of 21

14 Fig.: L2 Page 14 of 21

15 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM L3 - length from lowest renal artery to contralateral CIA landing zone= 204mm Page 15 of 21

16 Page 16 of 21

17 Fig.: L3 References: D. V. Thomas; Dept of Radiology, Northampton General Hospital, Northampton, UNITED KINGDOM Calculations - (See full planning sheet in the side bar). Main body To calculate the main body size, D1 needs to be oversized as follows - (Our example is in bold type) D1 vessel Stent L1 = CL limb mm IL limb mm TFFB-diameter TFFB-diameter TFFB-diameter TFFB-diameter TFFB-diameter Note - Although the L1 is 128 (and therefore a 125 body is possible), I would opt for a 111mm body to give a bit more room for manouvere. Hence the main body is TFFB Now we need to calculate the limb sizes. Page 17 of 21

18 Recommended diameter oversizing for the limbs are as shown - (again our example is in bold type) Vessel Stent or or or Available limb lengths for diameter diameter The diameter for the right limb based on a D2 of 12 would be 14mm and the diameter of the left limb based on a D3 of 13 would be 16mm. Limb Lengths The body-limb overlaps is built into the design. Our working limb length for the right side is L2-IL (Ipsilateral lim)b ie = 47mm. So I would opt for a 56mm limb length. Therefore our right limb is TFLE Page 18 of 21

19 Similarly the working limb length on the left is L3-CL (Contralateral limb) ie = 93mm. A 90mm limb length would be sufficient. So our left limb is TFLE The final order is therefore Main body - TFFB Right limb - TFLE Left limb - TFLE Images for this section: Page 19 of 21

20 Fig. 1: Planning Sheet Zenith Flex Main body and Legs Page 20 of 21

21 Conclusion An understanding of the required measurements and basic concepts used to plan an EVAR from a CTA is vital for all interventional radiologists and vascular surgeons. With the help of an example, this has been illustrated in this presentation. Although seemingly complex, once the basic principles are understood, then planning and sizing becomes easy. Personal Information I am a vascular interventional radiologist based in Northampton, UK. I can be contacted by on - davis.thomas@ngh.nhs.uk. References Product feature, Catalogue page and Resource Library Component ordering information - mmedia/ai-bm-fxztcoi-en pdf Page 21 of 21

Treatment options for endoleaks: stents, embolizations and conversions

Treatment options for endoleaks: stents, embolizations and conversions Treatment options for endoleaks: stents, embolizations and conversions Poster No.: C-0861 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit G. Lombardi; napoli/it Arteries / Aorta, Abdomen,

More information

64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes

64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes 64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes Poster No.: C-051 Congress: ECR 2009 Type: Scientific Exhibit Topic: Abdominal and Gastrointestinal Authors:

More information

Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine

Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine Poster No.: C-2125 Congress: ECR 2015 Type: Authors: Scientific Exhibit S. patil 1, A. M.

More information

Bell-bottoms, trouser grafts and crossovers: Maintaining pelvic perfusion with endovascular repair of aorto bi-iliac aneurysms

Bell-bottoms, trouser grafts and crossovers: Maintaining pelvic perfusion with endovascular repair of aorto bi-iliac aneurysms Bell-bottoms, trouser grafts and crossovers: Maintaining pelvic perfusion with endovascular repair of aorto bi-iliac aneurysms Poster No.: C-2031 Congress: ECR 2010 Type: Educational Exhibit Topic: Interventional

More information

Human Thiel cadaveric flow model for training aortic endovascular interventional techniques

Human Thiel cadaveric flow model for training aortic endovascular interventional techniques Human Thiel cadaveric flow model for training aortic endovascular interventional techniques Poster No.: C-2618 Congress: ECR 2015 Type: Educational Exhibit Authors: H. M. McLeod, A. Melzer, J. Robertson,

More information

Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography

Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography Poster No.: C-1342 Congress: ECR 2013 Type: Scientific Exhibit Authors:

More information

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006). Feasibility, image quality and radiation dose of coronary CT angiography (CCTA) in patients with atrial fibrillation using a new generation 256 multi-detector CT (MDCT) Poster No.: C-2378 Congress: ECR

More information

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT Poster No.: C-0623 Congress: ECR 2017 Type: Authors: Keywords: DOI:

More information

A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography.

A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography. A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography. Poster No.: C-1787 Congress: ECR 2012 Type: Educational Exhibit Authors: N. Ahmed 1, G. Avery

More information

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta 3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta Poster No.: C-1138 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Takahashi 1, Y. Takehara 2, H. Isoda

More information

Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time

Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time Poster No.: C-208 Congress: ECR 2009 Type: Educational Exhibit Topic: Chest Authors:

More information

High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous?

High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous? High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous? Poster No.: C-1753 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit B. Y. Lee, H. R. KIM, J. I. Jung,

More information

Quantitative imaging of hepatic cirrhosis on abdominal CT images

Quantitative imaging of hepatic cirrhosis on abdominal CT images Quantitative imaging of hepatic cirrhosis on abdominal CT images Poster No.: C-0556 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit S. Kido, A. Nakamura, Y. Hirano; Ube/JP Cirrhosis,

More information

Scientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2

Scientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2 Diagnosis of Acute Appendicitis: the role of Color Doppler Ultrasound as first-line imaging method and evaluation of the higher diagnostic performances of CT against its disadvantages. Poster No.: C-0708

More information

Scientific Exhibit Authors:

Scientific Exhibit Authors: Clinical Audit on Optimization of Radiation Dose from MDCT: Effect on Diagnostic Reference Levels for Brain, Sinus, Cervical Spine, Chest, Abdomen-Pelvis, and Lumbar Spine Examinations and on Nationwide

More information

Educational Exhibit Authors:

Educational Exhibit Authors: Endoleaks in Abdominal Aortic Aneurysm Endoprosthesis: What radiologists need to know about Diagnostic, Characterization and Basic Management Strategies Poster No.: C-0150 Congress: ECR 2013 Type: Educational

More information

Cognitive target MRI-TRUS fusion biopsies of MRI detected PIRADS 4 and 5 lesions

Cognitive target MRI-TRUS fusion biopsies of MRI detected PIRADS 4 and 5 lesions Cognitive target MRI-TRUS fusion biopsies of MRI detected PIRADS 4 and 5 lesions Poster No.: B-0704 Congress: ECR 2015 Type: Scientific Paper Authors: P. P. van Westerveld, J. Vriesema, J. H. W. van den

More information

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760 Can Weight-Adapted IV Contrast Media Protocols Reduce Iodine Dose and Still Produce a Diagnostic Contrast Enhancement Level in Abdomino-Pelvic CT Scans? Poster No.: C-1760 Congress: ECR 2015 Type: Authors:

More information

Basic low - field MR imaging of meniscal injuries in children.

Basic low - field MR imaging of meniscal injuries in children. Basic low - field MR imaging of meniscal injuries in children. Poster No.: C-2365 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit A. Yakimov, M. Nikonova, E. Prokhorova, D. Vybornov,

More information

Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation.

Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation. Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation. Award: Poster No.: E-0004 Certificate of Merit Congress:

More information

Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma

Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma Poster No.: C-0729 Congress: ECR 2013 Type: Scientific Exhibit Authors: A. Marin, I. Pozek,

More information

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour Monophasic versus biphasic contrast application in CT of patients with head and neck tumour Poster No.: C-3331 Congress: ECR 2010 Type: Topic: Authors: Keywords: DOI: Scientific Exhibit Head and Neck G.

More information

Influence of pulsed fluoroscopy and special radiation risk training on the radiation dose in pneumatic reduction of ileocoecal intussusceptions.

Influence of pulsed fluoroscopy and special radiation risk training on the radiation dose in pneumatic reduction of ileocoecal intussusceptions. Influence of pulsed fluoroscopy and special radiation risk training on the radiation dose in pneumatic reduction of ileocoecal intussusceptions. Poster No.: C-0599 Congress: ECR 2013 Type: Authors: Keywords:

More information

Medical device adverse incident reporting in interventional radiology

Medical device adverse incident reporting in interventional radiology Medical device adverse incident reporting in interventional radiology Poster No.: C-0226 Congress: ECR 2014 Type: Authors: Scientific Exhibit N. PARVIZI 1, I. Robertson 2, R. G. McWilliams 3 ; 1 Oxford/UK,

More information

Single cold nodule in Graves' disease: benign vs malignant

Single cold nodule in Graves' disease: benign vs malignant Single cold nodule in Graves' disease: benign vs malignant Poster No.: C-0073 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper L. I. Sonoda, M. Halim, K. Balan; Cambridge/UK Head and neck,

More information

Purpose. Methods and Materials. Results

Purpose. Methods and Materials. Results Prevalence and significance of hypoattenuating hepatic lesions deemed too small to characterise: How are we following up these lesions and what are the outcomes? Poster No.: C-014 Congress: ECR 2009 Type:

More information

Radiological features of Legionella Pneumophila Pneumonia

Radiological features of Legionella Pneumophila Pneumonia Radiological features of Legionella Pneumophila Pneumonia Poster No.: E-0048 Congress: ESTI 2012 Type: Scientific Exhibit Authors: M. Vinciguerra, L. Stefanetti, E. Teti, G. Argentieri, L. G. 1 1 1 1 1

More information

Retrograde dorsalis pedis and posterior tibial artery access after failed antegrade angioplasty

Retrograde dorsalis pedis and posterior tibial artery access after failed antegrade angioplasty Retrograde dorsalis pedis and posterior tibial artery access after failed antegrade angioplasty Poster No.: C-2067 Congress: ECR 2010 Type: Topic: Authors: Keywords: DOI: Scientific Exhibit Interventional

More information

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy 3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy Poster No.: C-0493 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper A. LONG

More information

Cierny-Mader classification of chronic osteomyelitis: Preoperative evaluation with cross-sectional imaging

Cierny-Mader classification of chronic osteomyelitis: Preoperative evaluation with cross-sectional imaging Cierny-Mader classification of chronic osteomyelitis: Preoperative evaluation with cross-sectional imaging Poster No.: C-590 Congress: ECR 2009 Type: Topic: Educational Exhibit Musculoskeletal Authors:

More information

Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology

Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology Poster No.: B-044 Congress: ECR 2011 Type: Scientific Paper Topic:

More information

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T. The feasibility of biphasic contrast-media-injection-protocol for chest imaging on 320-slice volume MDCT: Direct comparison of biphasic and bolus contrast-media injection protocols on 320-slice volume

More information

Cavitary lung lesion: Two different diagnosis with similar appearence

Cavitary lung lesion: Two different diagnosis with similar appearence Cavitary lung lesion: Two different diagnosis with similar appearence Poster No.: P-0043 Congress: ESTI 2015 Type: Educational Poster Authors: M. Yesildag, H. Kalkan, K. Ödev; Konya/TR Keywords: Infection,

More information

BI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation

BI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation BI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation e-poster: C-118 Congress: ECR 2008 Type: Educational Exhibit Topic: Breast / Ultrasound Authors:

More information

Radiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital

Radiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital Radiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital Poster No.: C-0892 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit A. Koo; Leeds, West Yorkshire/UK

More information

Valsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study.

Valsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study. Valsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study. Poster No.: C-0512 Congress: ECR 2012 Type: Authors: Keywords: DOI:

More information

Popliteal pterygium syndrome

Popliteal pterygium syndrome Popliteal pterygium syndrome Poster No.: C-1816 Congress: ECR 2011 Type: Educational Exhibit Authors: L. B. S. Santos, J. L. D. O. Schiavon, O. O. Guimaraes Neto, 1 1 2 3 1 1 C. A. P. Braga, R. S. LEMOS,

More information

Cryoplasty versus conventional angioplasty in peripheral arterial disease: 3 year analysis of reintervention free survival by treatment received.

Cryoplasty versus conventional angioplasty in peripheral arterial disease: 3 year analysis of reintervention free survival by treatment received. Cryoplasty versus conventional angioplasty in peripheral arterial disease: 3 year analysis of reintervention free survival by treatment received. Poster No.: C-0343 Congress: ECR 2011 Type: Scientific

More information

The "filling defect" sign helps localise the site of intracranial aneurysm rupture on an unenhanced CT

The filling defect sign helps localise the site of intracranial aneurysm rupture on an unenhanced CT The "filling defect" sign helps localise the site of intracranial aneurysm rupture on an unenhanced CT Poster No.: C-3380 Congress: ECR 2010 Type: Topic: Authors: Keywords: DOI: Educational Exhibit Neuro

More information

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Poster No.: C-1785 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific

More information

Diffusion-weighted MRI (DWI) "claw sign" is useful in differentiation of infectious from degenerative Modic I signal changes of the spine

Diffusion-weighted MRI (DWI) claw sign is useful in differentiation of infectious from degenerative Modic I signal changes of the spine Diffusion-weighted MRI (DWI) "claw sign" is useful in differentiation of infectious from degenerative Modic I signal changes of the spine Poster No.: C-0894 Congress: ECR 2012 Type: Scientific Exhibit

More information

Seemingly isolated greater trochanter fractures do not exist

Seemingly isolated greater trochanter fractures do not exist Seemingly isolated greater trochanter fractures do not exist Poster No.: B-0950 Congress: ECR 2012 Type: Scientific Paper Authors: D. Dunker, J. H. Göthlin, M. Geijer ; Gothenburg/SE, Lund/SE Keywords:

More information

The Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities

The Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities The Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities Poster No.: C-1229 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit M. Osher 1, A. Pallas

More information

Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference

Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference Poster No.: C-934 Congress: ECR 202 Type: Scientific Exhibit

More information

Gastric banding: What radiologists need to know

Gastric banding: What radiologists need to know Gastric banding: What radiologists need to know Poster No.: C-1606 Congress: ECR 2010 Type: Educational Exhibit Topic: GI Tract Authors: D. V. Thomas, G. Finch; Northampton/UK Keywords: Laparoscopic gastric

More information

Outcomes of endovascular aortic aneurysm repair in patients with hostile neck anatomy

Outcomes of endovascular aortic aneurysm repair in patients with hostile neck anatomy Outcomes of endovascular aortic aneurysm repair in patients with hostile neck anatomy Poster No.: C-2033 Congress: ECR 2010 Type: Scientific Exhibit Topic: Interventional Radiology Authors: Y. R. Choi,

More information

The "whirl sign". Diagnostic accuracy for intestinal volvulus.

The whirl sign. Diagnostic accuracy for intestinal volvulus. The "whirl sign". Diagnostic accuracy for intestinal volvulus. Poster No.: C-0670 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Pire, M. Marti, A. Borobia, A. Verón; Madrid/ES Keywords: Abdomen,

More information

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:

More information

Endovascular Repair Of Traumatic, Degenerative And Mycotic Aortic Aneurysms: A Single Center Experience

Endovascular Repair Of Traumatic, Degenerative And Mycotic Aortic Aneurysms: A Single Center Experience Endovascular Repair Of Traumatic, Degenerative And Mycotic Aortic Aneurysms: A Single Center Experience Poster No.: C-2349 Congress: ECR 2014 Type: Scientific Exhibit Authors: Y. M. H. Al Bulushi, R. ALSukaiti;

More information

Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH)

Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH) Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH) Poster No.: C-0964 Congress: ECR 2010 Type: Scientific

More information

Long bones manifestations of congenital syphilis

Long bones manifestations of congenital syphilis Long bones manifestations of congenital syphilis Poster No.: C-0139 Congress: ECR 2011 Type: Educational Exhibit Authors: T. F. de Souza 1, P. P. Collier 1, E. J. M. Bronzatto 1, G. L. P. Keywords: DOI:

More information

Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos

Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos Poster No.: C-3032 Congress: ECR 2010 Type: Scientific Exhibit Topic: Radiographers Authors: P.

More information

Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis

Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis Poster No.: C-1887 Congress: ECR 2016 Type: Authors: Keywords: DOI: Educational Exhibit M.

More information

Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner.

Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner. Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner. Poster No.: C-2613 Congress: ECR 2015 Type: Authors: Keywords: DOI: Scientific Exhibit

More information

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:

More information

Can aortic aneurysm growth rate be predicted in clinical practice using 18-fluorodeoxyglucose positron emission tomography (18-FDG PET)?

Can aortic aneurysm growth rate be predicted in clinical practice using 18-fluorodeoxyglucose positron emission tomography (18-FDG PET)? Can aortic aneurysm growth rate be predicted in clinical practice using 18-fluorodeoxyglucose positron emission tomography (18-FDG PET)? Poster No.: C-1743 Congress: ECR 2011 Type: Authors: Keywords: DOI:

More information

Hyperechoic breast lesions can be malignant.

Hyperechoic breast lesions can be malignant. Hyperechoic breast lesions can be malignant. Poster No.: C-0041 Congress: ECR 2015 Type: Educational Exhibit Authors: G. Babu, R. bradley; Edinburgh/UK Keywords: Breast, Ultrasound, Biopsy, Cancer DOI:

More information

Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer

Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer Poster No.: C-1260 Congress: ECR 2011 Type: Scientific Paper Authors: K. M. Kulkarni,

More information

Our experience in the endovascular treatment of female varicocele

Our experience in the endovascular treatment of female varicocele Our experience in the endovascular treatment of female varicocele Poster No.: C-0347 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit A. Sáez de Ocáriz García, M. M. Mendigana Ramos,

More information

"Ultrasound measurements of the lateral ventricles in neonates: A comparison of multiple measurements methods."

Ultrasound measurements of the lateral ventricles in neonates: A comparison of multiple measurements methods. "Ultrasound measurements of the lateral ventricles in neonates: A comparison of multiple measurements methods." Poster No.: C-1557 Congress: ECR 2014 Type: Authors: Keywords: DOI: Educational Exhibit I.

More information

Duret hemorraghe caused by traumatic brain injury: what the radiologist should know.

Duret hemorraghe caused by traumatic brain injury: what the radiologist should know. Duret hemorraghe caused by traumatic brain injury: what the radiologist should know. Poster No.: C-1270 Congress: ECR 2012 Type: Educational Exhibit Authors: P. Dewachter 1, T. Vanderhasselt 1, K. De Smet

More information

CT assessment of acute coalescent mastoiditis.

CT assessment of acute coalescent mastoiditis. CT assessment of acute coalescent mastoiditis. Poster No.: C-1794 Congress: ECR 2010 Type: Educational Exhibit Topic: Head and Neck Authors: A. Thomson, S. J. Thomas, A. Hutchings, E. Tilley; Portsmouth/UK

More information

PI-RADS classification: prognostic value for prostate cancer grading

PI-RADS classification: prognostic value for prostate cancer grading PI-RADS classification: prognostic value for prostate cancer grading Poster No.: C-1622 Congress: ECR 2014 Type: Scientific Exhibit Authors: I. Platzek, A. Borkowetz, T. Paulus, T. Brauer, M. Wirth, M.

More information

Multislice CT versus cone beam CT: dosimetric and image quality comparision.

Multislice CT versus cone beam CT: dosimetric and image quality comparision. Multislice CT versus cone beam CT: dosimetric and image quality comparision. Poster No.: C-2589 Congress: ECR 2015 Type: Authors: Scientific Exhibit C. Dionisi 1, A. Crispo 2, E. Stefani 3, A. Lovaglio

More information

Comparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence

Comparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence Comparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence Poster No.: C-1065 Congress: ECR 2015 Type: Authors: Keywords: DOI: Scientific Exhibit

More information

Novel hybrid nitinol ring stent (TIGRIS Gore)placement for atherosclerotic disease in the popliteal artery in 50 limbs

Novel hybrid nitinol ring stent (TIGRIS Gore)placement for atherosclerotic disease in the popliteal artery in 50 limbs Novel hybrid nitinol ring stent (TIGRIS Gore)placement for atherosclerotic disease in the popliteal artery in 50 limbs Poster No.: C-2437 Congress: ECR 2015 Type: Scientific Exhibit Authors: A. Parthipun,

More information

Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases

Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases Poster No.: P-0075 Congress: ESTI 2014 Type: Authors: Educational Poster J. J. Woo 1, K. Y. Lee 2, Y. Cho 1, J.

More information

PET/CT depiction of ATS mediastinal nodal stations: What every radiologist should know - diagnostic strategies and potential pitfalls

PET/CT depiction of ATS mediastinal nodal stations: What every radiologist should know - diagnostic strategies and potential pitfalls PET/CT depiction of ATS mediastinal nodal stations: What every radiologist should know - diagnostic strategies and potential pitfalls Poster No.: C-236 Congress: ECR 2009 Type: Educational Exhibit Topic:

More information

Time efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT

Time efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT Time efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT Poster No.: C-0636 Congress: ECR 2012 Type: Scientific Paper Authors: T. De

More information

PGMI classification of screening mammograms prior to interval cancer. Comparison with radiologists' consensus classification.

PGMI classification of screening mammograms prior to interval cancer. Comparison with radiologists' consensus classification. PGMI classification of screening mammograms prior to interval cancer. Comparison with radiologists' consensus classification. Poster No.: C-0673 Congress: ECR 2016 Type: Authors: Keywords: DOI: Scientific

More information

Comparison of MRI and ultrasound based liver volumetry in iron overload diseases

Comparison of MRI and ultrasound based liver volumetry in iron overload diseases Comparison of MRI and ultrasound based liver volumetry in iron overload diseases Poster No.: C-0913 Congress: ECR 2015 Type: Scientific Exhibit Authors: S. Keller, B. P. Schönnagel, P. Nielsen, M. T. Brehmer,

More information

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Poster No.: B-0742 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Paper

More information

Emergency endovascular repair of ruptured abdominal aortic aneurysms - our experience

Emergency endovascular repair of ruptured abdominal aortic aneurysms - our experience Emergency endovascular repair of ruptured abdominal aortic aneurysms - our experience Poster No.: C-0837 Congress: ECR 2011 Type: Scientific Paper Authors: D. Kuhelj, M. Baraga, P. Popovi#, T. Klju#evšek,

More information

Using diffusion-tensor imaging and tractography (DTT) to study biological characteristics of glyoma in brain stem for neurosurgical planning

Using diffusion-tensor imaging and tractography (DTT) to study biological characteristics of glyoma in brain stem for neurosurgical planning Using diffusion-tensor imaging and tractography (DTT) to study biological characteristics of glyoma in brain stem for neurosurgical planning Poster No.: C-0016 Congress: ECR 2014 Type: Authors: Keywords:

More information

Is ascites a sensible predictive sign of peritoneal involvement in patients with ovarian carcinoma?: our experience with FDG-PET/CT

Is ascites a sensible predictive sign of peritoneal involvement in patients with ovarian carcinoma?: our experience with FDG-PET/CT Is ascites a sensible predictive sign of peritoneal involvement in patients with ovarian carcinoma?: our experience with FDG-PET/CT Poster No.: C-1019 Congress: ECR 2013 Type: Scientific Exhibit Authors:

More information

Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures

Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures Poster No.: C-0669 Congress: ECR 2014 Type: Scientific Exhibit Authors: J. Tonak, I. Wobbe, R. L. Duschka,

More information

Imaging Gorham's disease (vanishing bone)

Imaging Gorham's disease (vanishing bone) Imaging Gorham's disease (vanishing bone) Poster No.: C-2201 Congress: ECR 2010 Type: Scientific Exhibit Topic: Musculoskeletal Authors: D. Vanel, P. Ruggieri, M. Alberghini; Bologna/IT Keywords: Gorham,

More information

Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil

Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil Poster No.: C-0671 Congress: ECR 2016 Type: Educational Exhibit Authors: H. Patel 1, W. Liu 2, J. DeSanto 2, S. Meagher 2, M. Zagardo 2,

More information

MRI and MRCP in acute edematous interstitial pancreatitis

MRI and MRCP in acute edematous interstitial pancreatitis MRI and MRCP in acute edematous interstitial pancreatitis Poster No.: C-0212 Congress: ECR 2010 Type: Scientific Exhibit Topic: Abdominal Viscera (Solid Organs) - Pancreas Authors: M. Di Girolamo, A. Grossi,

More information

Audit on the Complication Rates of Angioseal Vascular Closure Devices

Audit on the Complication Rates of Angioseal Vascular Closure Devices Audit on the Complication Rates of Angioseal Vascular Closure Devices Poster No.: C-1359 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit S. Abdulla, H. Rafiee, M. Crawford; Norwich/UK

More information

Computed tomography for the detection of thumb base osteoarthritis, comparison with digital radiography.

Computed tomography for the detection of thumb base osteoarthritis, comparison with digital radiography. Computed tomography for the detection of thumb base osteoarthritis, comparison with digital radiography. Poster No.: C-1981 Congress: ECR 2012 Type: Scientific Exhibit Authors: M. S. Saltzherr, J. W. van

More information

Assessment of renal cell carcinoma by two PET tracer : dual-time-point C-11 methionine and F-18 fluorodeoxyglucose

Assessment of renal cell carcinoma by two PET tracer : dual-time-point C-11 methionine and F-18 fluorodeoxyglucose Assessment of renal cell carcinoma by two PET tracer : dual-time-point C-11 methionine and F-18 fluorodeoxyglucose Poster No.: C-0805 Congress: ECR 2015 Type: Scientific Exhibit Authors: S. Ito, K. Kato,

More information

Single ventricle on cardiac MRI

Single ventricle on cardiac MRI Single ventricle on cardiac MRI Poster No.: C-0414 Congress: ECR 2011 Type: Scientific Exhibit Authors: F. Secchi, V. G. Nardella, A. Giardino, G. Di Leo, F. 1 2 1 1 1 1 2 Sardanelli ; Milano/IT, Milan/IT

More information

How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter

How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter Poster No.: C-0281 Congress: ECR 2013 Type: Scientific

More information

Evaluation of BI-RADS 3 lesions in women with a high risk of hereditary breast cancer.

Evaluation of BI-RADS 3 lesions in women with a high risk of hereditary breast cancer. Evaluation of BI-RADS 3 lesions in women with a high risk of hereditary breast cancer. Poster No.: C-0346 Congress: ECR 2014 Type: Scientific Exhibit Authors: A. Thomas 1, R. Dominguez Oronoz 1, S. Roche

More information

Intra-abdominal abscesses radiology diagnostic

Intra-abdominal abscesses radiology diagnostic Intra-abdominal abscesses radiology diagnostic Poster No.: C-2320 Congress: ECR 2012 Type: Scientific Exhibit Authors: K. Viksna; Riga/LV Keywords: Abscess, Computer Applications-Detection, diagnosis,

More information

Abdominal Vascular Emergencies in MDCT Imaging

Abdominal Vascular Emergencies in MDCT Imaging Abdominal Vascular Emergencies in MDCT Imaging Poster No.: C-0913 Congress: ECR 2016 Type: Educational Exhibit Authors: K. SHIRODKAR, D. N. Dasappa, S. L. DEVARU, D. S. 1 2 2 2 2 2 1 Nandikoor, A. R. Patil,

More information

Lusory Artery - random finding without further implications or important challenge which conditions treatment strategy.

Lusory Artery - random finding without further implications or important challenge which conditions treatment strategy. Lusory Artery - random finding without further implications or important challenge which conditions treatment strategy. Poster No.: C-2118 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit

More information

Imaging characterization of renal clear cell carcinoma

Imaging characterization of renal clear cell carcinoma Imaging characterization of renal clear cell carcinoma Poster No.: C-0327 Congress: ECR 2011 Type: Educational Exhibit Authors: S. Ballester 1, A. Gaser 2, M. Dotta 1, M. F. CAPPA 1, F. Hammar 1 ; 1 2

More information

Doppler ultrasound as noninvasive diagnosis of peripheral arterial disease

Doppler ultrasound as noninvasive diagnosis of peripheral arterial disease Doppler ultrasound as noninvasive diagnosis of peripheral arterial disease Poster No.: C-0246 Congress: ECR 2012 Type: Scientific Exhibit Authors: C. Ballester Valles, F. Aparici-Robles; Valencia/ES Keywords:

More information

Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study

Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study Poster No.: R-0016 Congress: 2015 ASM Type: Scientific Exhibit Authors: J. Au, A. Webb, G. Buirski, P. Smith, M. Pickering, D.

More information

The effect of CT dose reduction on performance of a diagnostic task

The effect of CT dose reduction on performance of a diagnostic task The effect of CT dose reduction on performance of a diagnostic task Poster No.: B-0856 Congress: ECR 2012 Type: Scientific Paper Authors: D. Zhang, M. Khatonabadi, H. Kim, C. Jude, E. Zaragoza, S. McNitt-Gray,

More information

The effect of CT dose reduction on performance of a diagnostic task

The effect of CT dose reduction on performance of a diagnostic task The effect of CT dose reduction on performance of a diagnostic task Poster No.: B-0856 Congress: ECR 2012 Type: Scientific Paper Authors: D. Zhang, M. Khatonabadi, H. Kim, C. Jude, E. Zaragoza, S. McNitt-Gray,

More information

Ultrasonic evaluation of superior mesenteric vein in cancer of the pancreatic head

Ultrasonic evaluation of superior mesenteric vein in cancer of the pancreatic head Ultrasonic evaluation of superior mesenteric vein in cancer of the pancreatic head Poster No.: C-1430 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit E. Fisenko, N. Vetsheva, E. Pershina;

More information

NICE Guidelines for C-Spine Imaging: Real Life Impact

NICE Guidelines for C-Spine Imaging: Real Life Impact NICE Guidelines for C-Spine Imaging: Real Life Impact Poster No.: C-1367 Congress: ECR 2017 Type: Scientific Exhibit Authors: D. Weinberg, I. Djoukhadar, G. Potter; Salford/UK Keywords: Trauma, Audit and

More information

Contrast enhancement of the right ventricle during coronary CTA: is it necessary?

Contrast enhancement of the right ventricle during coronary CTA: is it necessary? Contrast enhancement of the right ventricle during coronary CTA: is it necessary? Poster No.: C-1545 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit M. Kok, C. Mihl, B. Kietselaer,

More information

Risk Management as a Part of Quality Management System. MRI Private Clinic. Russia

Risk Management as a Part of Quality Management System. MRI Private Clinic. Russia Risk Management as a Part of Quality Management System. MRI Private Clinic. Russia Poster No.: C-0078 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Yastrebova 1, A. K. Karpenko 1, T. Trofimova

More information

Acute abdominal venous thromboses- the hyperdense noncontrast CT sign

Acute abdominal venous thromboses- the hyperdense noncontrast CT sign Acute abdominal venous thromboses- the hyperdense noncontrast CT sign Poster No.: C-1095 Congress: ECR 2011 Type: Educational Exhibit Authors: M. Goldstein, K. Jhaveri; Toronto, ON/CA Keywords: Abdomen,

More information

Percutaneous transluminal angioplasty in the treatment of stenosis of hemodialysis arteriovenous fistulae: our experience

Percutaneous transluminal angioplasty in the treatment of stenosis of hemodialysis arteriovenous fistulae: our experience Percutaneous transluminal angioplasty in the treatment of stenosis of hemodialysis arteriovenous fistulae: our experience Poster No.: C-3355 Congress: ECR 2010 Type: Scientific Exhibit Topic: Interventional

More information

MDCT signs differentiating retroperitoneal and intraperitoneal lesions- diagnostic pearls

MDCT signs differentiating retroperitoneal and intraperitoneal lesions- diagnostic pearls MDCT signs differentiating retroperitoneal and intraperitoneal lesions- diagnostic pearls Poster No.: C-0987 Congress: ECR 2015 Type: Educational Exhibit Authors: D. V. Bhargavi, R. Avantsa, P. Kala; Bangalore/IN

More information