APCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop. Dr Matthew Grigg Asia Pacific Marketing and Support Manager

Size: px
Start display at page:

Download "APCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop. Dr Matthew Grigg Asia Pacific Marketing and Support Manager"

Transcription

1 APCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop Dr Matthew Grigg Asia Pacific Marketing and Support Manager

2 Applied Biosystems LLC and MDS Inc. Joint Owners

3 AB SCIEX Tandem MS Product Portfolio Hybrid Systems 3200 Q TRAP LC/MS/MS System QSTAR ELITE LC/MS/MS System 4000 Q TRAP LC/MS/MS System QTRAP 5500 LC/MS/MS System Food and Beverage Environmental Forensic Clinical Triple Quad Systems Software Solutions API 2000 LC/MS/MS System API 3200 LC/MS/MS System API 4000 LC/MS/MS System Applied Biosystems LLC and MDS Inc. Joint Owners Triple Quad 5500 LC/MS/MS System

4 Use of MS in Clinical Research Applications TDM NBS Biomarker Clin Tox Immunosuppressant Antiretroviral Antipsychotics Anticonvulsive Antiviral Benzodiazepine Diseases Fatty Acid Oxidation Disorder Amino Acid Disorders Organic Acid Steroids T3/T4 Vitamin D Homocysteine Orotic Acid VLCFA General unknown identification Drugs Of Abuse (DOA) Disorders Bile Acid Other Diseases Cancer Etc. API 3200 API 3200 API 3200 to 5000 Q TRAP Applied Biosystems LLC and MDS Inc. Joint Owners

5 Creating Complete Solutions For Routine Analysis Hardware Unique QTrap & TMS Technology Best in Class HPLC Customer Support Installation and training Phone/On-site application support Market Specific Solution Software Cliquid 2.0 Software ChemoView Software imethod Tests Application specific methods MRM Catalogues and Libraries Harnessing the power of Tandem MS: Best-in-class hardware + Easy to use software + Customizable applications solutions Get customers up and running quickly Applied Biosystems LLC and MDS Inc. Joint Owners

6 Cliquid software a new turn key solution Applied Biosystems LLC and MDS Inc. Joint Owners

7 Cliquid Software Goals Goal to provide virtually trainingless solution for LC/MS/MS applications Workflow framework for routine testing Allow users to focus on proper sample prep! Provide expert user with the ability to deploy sophisticated methodologies with little or no training to laboratory technicians Provide complete solutions with pre-configured tests and reports matching regulatory guidelines The Simplest Cliquid 3.0 Workflow Click on Run Samples Choose a Test Build Sample List Name Job and Submit Applied Biosystems LLC and MDS Inc. Joint Owners

8 Cliquid Software and imethod Tests Create custom solutions with easy-to-use Cliquid Software and downloadable pre-configured imethod Tests Food Safety Testing Environmental Monitoring Clinical Research Toxicology Secure and simple four step workflow Pre-configured system suitability tests to ensure optimal systems performance Pre-configured report templates created according to regulatory guidelines Supports English, Japanese and simplified Chinese languages Applied Biosystems LLC and MDS Inc. Joint Owners

9 Increasing Productivity : Increasing Throughput The New Cliquid MPX -2 High Throughput System

10 Cliquid MPX -2 High Throughput System NEW Multiplexing of two HPLCs into a single Mass Spectrometer Applied Biosystems LLC and MDS Inc. Joint Owners

11 Based Upon Customer Input + = More Samples Less Time Savings A new way to increase instrument utilization Applied Biosystems LLC and MDS Inc. Joint Owners

12 Cliquid MPX -2 High Throughput System NEW Key Features: Single point of control software Audit trail / traceability for compliance Intuitive, simple to use method editor Flexible reporting options. Run 1 Real-time instrument status High Pressure HPLC Compatible Run 2 Single vendor solution Simple Cliquid Software workflow Run 3 Supported for use in either Analyst or Cliquid Software Multiplexing of two HPLCs into a single Mass Spectrometer Applied Biosystems LLC and MDS Inc. Joint Owners

13 XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) Max. 8.1e4 cps e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. XIC of +MRM (4 pairs): 210.2/164.2 Da from Sample 9 (STD 5) of Mix_batch_1.wiff (Unknown Ion Source) 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e Time, min Max. 8.1e4 cps. How Multiplex LC Works Designed to Support Two Parallel LC Streams into a Single MS idle acquire from stream 1 acquire from stream 2 wait for sync signal Example of staggered injections from two HPLC systems running the same method 1 inject to stream N send sync signal Applied Biosystems LLC and MDS Inc. Joint Owners

14 Method Editor View A single screen within Analyst Software to input all HPLC parameters Applied Biosystems LLC and MDS Inc. Joint Owners

15 Instrument Status View A second screen to monitor the real time instrument status Applied Biosystems LLC and MDS Inc. Joint Owners

16 Example Analysis

17 Example: Vitamin D Analysis XIC of +MRM (5 pairs): 383.4/229.2 Da ID: Vit-D3-2 from Sample 4 (Vitamin D Recipe QC2) of 2009_03_12_173017_12Mar09_VitD_ e4 8.0e4 Max. 4.5e4 cps. 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 OH-Vitamin-D 3 4 th Injection 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 OH-Vitamin-D 2 2.0e4 1.5e4 1.0e XIC of +MRM (5 pairs): 383.4/229.2 Da ID: Vit-D3-2 from Sample 50 (Vitamin D Recipe QC2) of Time, 2009_03_12_173017_12Mar09_VitD_00... min Max. 5.5e4 cps. 8.3e4 8.0e4 7.5e4 7.0e4 6.5e4 6.0e4 5.5e4 5.0e4 4.5e4 4.0e4 3.5e4 3.0e4 2.5e4 2.0e4 1.5e4 1.0e th Injection Time, min Two fold increase in throughput: 100 injections, Singleplex Run Time:>6 hr 30 min 100 injections, Multiplex Run Time: 3 hr 30 min Time saved: 3 hr Applied Biosystems LLC and MDS Inc. Joint Owners

18 Example: Amino Acid Analysis XIC of +MRM (72 pairs): 330.1/115.1 amu Expected RT: 2.2 ID: PSer_IS from Sample 3 (Sample003) of Mutiple batches aa45.wiff (Turb... Max. 6.0e4 cps. 5.2e5 5.0e5 4.8e5 4.6e5 4.4e5 4.2e5 4.0e5 3.8e5 3.6e5 3.4e5 3.2e5 3.0e5 2.8e5 2.6e5 2.4e5 2.2e5 2.0e5 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 8.0e e4 4.0e4 2.0e Time, min Two fold increase in throughput: 10 AA45 sample injections Singleplex Run Time : >200 min Multiplex Run Time: 89 min Time saved: 111 min Applied Biosystems LLC and MDS Inc. Joint Owners

19 Increasing Productivity : Increasing Throughput Online Sample Prep -

20 Conditioning Equilibration Sample Application Washes Evaporation Reconstitution N 2 OFF-LINE ON-LINE Analytical Column Analytical Column Injection On-line vs Off-line SPE Drying Analyte elution Switch valve Applied Biosystems LLC and MDS Inc. Joint Owners

21 Symbiosis PICO System The Pico system is integrated with the full line of ABI MS systems Applied Biosystems LLC and MDS Inc. Joint Owners

22 Symbiosis On-line Technique How It Operates Applied Biosystems LLC and MDS Inc. Joint Owners

23 Software Integration Optimal Workflow Main features Analyst 1.5 Security & audit trailing (21 CFR Part 11 compliant) Seamless integration in to Analyst 1.5 Method editor Batch editor Applied Biosystems LLC and MDS Inc. Joint Owners

24 imethod TM Test for Analysis of Four Immunosuppressants XICof +MRM(6pairs): /425.4DaID: CyclosporineAfromSample 33 (Cal 6) of 2008_12_12_182119_Immunosuppressant.wiff (Turbo... Max. 2.3e5 cps. Method Info: API 3200 LC/MS/MS System Spark PICO system with Mistral column oven AB POROS R1 sorbent Phenomenex Luna 5 u Phenyl-Hexyl 50 x 2.1 mm HPLC Analyte LLOQ ng/ml Cyclosporine 47.1 Tacrolimus 2.3 Sirolimus 2.4 Everolimus Applied Biosystems LLC and MDS Inc. Joint Owners 2.3e5 2.2e5 2.1e5 2.0e5 1.9e5 1.8e5 1.7e5 1.6e5 1.5e5 1.4e5 1.3e5 1.2e5 1.1e5 1.0e5 9.0e4 8.0e4 7.0e4 6.0e4 5.0e4 4.0e4 3.0e4 2.0e4 1.0e4 0.0 Tacrolimus (44.0 ng/ml) Everolimus (44.1 ng/ml) Ascomycin (IS) Sirolimus (48.2 ng/ml) 1.35 Cyclosporine A (1743 ng/ml) Cyclosporine D (IS) Time, min Chromatogram of Chromsystems Whole Blood Calibrator Level 6

25 imethod TM Test for 25-Mono-Hydroxy-Vitamin D2 and 25-Mono-Hydroxy- Vitamin D3 in Human Plasma XIC of +MRM (3 pairs): 383.1/211.1 Da ID: MHVD 3 from Sample 5 (100 ng/ml) of cal curve.wiff (Heated Nebulizer) Max. 4.3e4 cps. 4.2e Method Info: API 4000 LC/MS/MS System In te n s ity, c p s 4.0e4 3.8e4 3.6e4 3.4e4 3.2e4 3.0e4 2.8e4 2.6e4 2.4e4 2.2e4 2.0e4 1.8e4 1.6e4 1.4e4 1.2e4 1.0e Time, min Chromatogram of a 100 ng/ml MHVD3 in plasma Spark PICO system with Mistral column oven Spark HySphere C8EC SE sorbent SPE cartridge Merck Chromolith SpeedROD RP-18e 50x4.6 mm HPLC column LLOQ: 5 ng/ml Applied Biosystems LLC and MDS Inc. Joint Owners MHVD3 Cal Curve, ng/ml

26 orclinicalresearch/index.htm Applied Biosystems LLC and MDS Inc. Joint Owners

27 Analysis by LC-MS/MS Development of an imethod TM Test

28 How imethod Test was Developed Literature search on most recent publication and reference levels to set goals Sample volume; run time; sample preparation; detection limits; curve and QC ranges Method development: established detail requirements for method validation and sample analysis selectivity, accuracy, precision, recovery, reproducible and matrix effects Three runs to establish method documents Intra-day and inter-day; over 100 samples for each batch Three verification runs from different labs and scientists Feed back and modify method and documents Final imethod test documentation Chemical and reagent supply; sample preparation procedure; HPLC conditions; MS/MS conditions; example chromatogram; tricks and tips Applied Biosystems LLC and MDS Inc. Joint Owners

29 Trace Level Estrogen Analysis Applied Biosystems LLC and MDS Inc. Joint Owners

30 The Importance of Estrogens Estrogen is an entire class of related female sex hormones: estrone (E1) estradiol (E2), and estriol (E3) Estrone (E1) is widespread throughout the body. It is the only one of estrogens that s present in any amount in women after menopause. Estradiol (E2) is the primary sex hormone of childbearing women. It is formed from developing ovarian follicles. Estradiol is responsible for female characteristics and sexual functioning. Also, estradiol is important to women s bone health. Estradiol contributes to most gynecologic problems and even female cancers. Estriol (E3) is made from the placenta. It s important only during pregnancy Applied Biosystems LLC and MDS Inc. Joint Owners

31 Summary of Estrogens Reference Levels Population Estrone (E1) Estradiol (E2) Estriol(E3) (Pregnancy) Adult Male pg/ml pg/ml < 2ng/mL Premenopausal Female pg/ml pg/ml Postmenopausal Female pg/ml <10 pg/ml (Pregnancy) ng/ml (non-pregnancy) <2 ng/ml Target LOQ 5 pg/ml 5 pg/ml < 10 pg/ml ULQ pg/ml pg/ml 2000 pg/ml TIETZ Textbook of Clinical Chemistry and Molecular Diagnostics; 4 th Edition Estradiol: LC-MSMS test: 300K- 500K samples in US for one year Reference: Steroids 73 (2008) ; Steroids 73 (2008) Applied Biosystems LLC and MDS Inc. Joint Owners

32 The Fragmentation of Estradiol on APCI LC-MSMS Estradiol H2O Ring open fragments -H2O Applied Biosystems LLC and MDS Inc. Joint Owners

33 The Fragmentation of Estradiol on ESI Neg LC-MSMS (Less interferences from other steroids in neg mode) Estradiol _Neg No ring open fragments Applied Biosystems LLC and MDS Inc. Joint Owners

34 Factors Were Considered and Evaluated Different organic solvent combination for liquid-liquid extraction Derivatization with dansyl has also been evaluated High background and interference IS impurity interference and stability IS is not very stable at low concentration Interferences from other endogenous level steroids No major interference from other steroids to E1 and E2 in neg ionization mode Run time: 6min Column wash with high organic is important for the roughness of assay Different phase columns have been tested C18, C8, Bi-phenyl, hydro-rp Gemini ESI or APCI APCI pos is less sensitive than ESI neg with mobile phase modifier Non-specific binding High non-specific binding for E1 and E2 Glass labware and injection vial are recommended Applied Biosystems LLC and MDS Inc. Joint Owners

35 Conditions: Verified Instrumentation Estrone and Estradiol: API 5000 and AB SCIEX Triple Quad 5500 Mass Spectrometers Shimadzu Prominence 20A and Agilent 1200 integrated systems Method Information 500 µl sample volume required Liquid-liquid extraction without derivatization Clinically relevant dynamic range of pg/ml 6 minute total run time Applied Biosystems LLC and MDS Inc. Joint Owners

36 Estrone and Estradiol: Lower Limit of Quantitation Estrone 5 pg/ml LLOQ, S/N=22 Estradiol 5 pg/ml LLOQ, S/N= Applied Biosystems LLC and MDS Inc. Joint Owners

37 Sensitivity: LQC in Human Serum E3 at LQC 30 pg/ml S/N= Applied Biosystems LLC and MDS Inc. Joint Owners

38 Estrone and Estradiol: Precision and Accuracy Estrone (E1) Sample (pg/ml) %CV % Accuracy Estradiol (E2) Sample (pg/ml) %CV % Accuracy Day 1-3 Day 1-3 LLOQ (5) Low QC (15) High QC (100) ULOQ (500) Day 1-3 Day 1-3 LLOQ (5) Low QC (15) 4 96 High QC (100) ULOQ (500) Estrone (inter-day) LLOQ CV s 9%,QC s CV s 5% Accuracy deviation 4% Estradiol (inter-day) LLOQ CV s 10%,QC s CV s 5% Accuracy deviation 4% Applied Biosystems LLC and MDS Inc. Joint Owners

39 Estrone and Estradiol: Linearity Estrone Estradiol Clinically relevant dynamic range pg/ml, R Applied Biosystems LLC and MDS Inc. Joint Owners

40 Roughness of Assay: Estrone Low QC Analyte to IS ratio Analyte peak area Retention Time Applied Biosystems LLC and MDS Inc. Joint Owners

41 Estrone and Estradiol: Summary The method was verified internally across laboratories for analytical analysis LLOQ with suitable signal to noise (20) Inter-day Precision and Accuracy LLOQ CVs 10%,QCs CV s 5% Accuracy Deviation ±4% Control samples at clinically relevant low and high concentrations (5-500 pg/ml) with linear response r Two steps liquid liquid extraction without derivatization 6 minutes run time Applied Biosystems LLC and MDS Inc. Joint Owners

42 Summary AB SCIEX is extending its leadership in the mass spectrometry market to new markets and applications Simplifying mass spectrometry for applied markets and clinical research Will continue on complete workflow solutions Systems Software Methods and Kits Training Support Applied Biosystems LLC and MDS Inc. Joint Owners

43 Acknowledgements Beth Frenandez Tania Sasaki Elliott Jones Lisa Sapp David Lavorato Adam Latawiec; Theresa Lee; Peter Lodenquai; Susan Leonard Applied Biosystems LLC and MDS Inc. Joint Owners

44 Legal Acknowledgments For Research Use Only. Not for use in diagnostic procedures The trademarks mentioned herein are the property of either Life Technologies Corporation, Applied Biosystems/MDS Analytical Technologies, or otherwise, their respective owners 2009 Applied Biosystems LLC and MDS Inc. Joint Owners. All Rights Reserved Applied Biosystems LLC and MDS Inc. Joint Owners

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

An Introduction to the Use of itraq Reagents for Amino Acid Analysis

An Introduction to the Use of itraq Reagents for Amino Acid Analysis An Introduction to the Use of itraq Reagents for Amino Acid Analysis Lisa Sapp Clinical Research and Forensic Toxicology Product Manager Mass Spectrometry Systems Amino Acid Analysis Using itraq Reagents

More information

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma Shaokun Pang 1, Weixing Sun 2, Adrien Musuku 2, Xavier J. Misonne 1 1 SCIEX,

More information

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA Quantification of four immunosuppressant drugs by Liquid Chomatography-Tandem Mass Spectrometry using Direct Injection. Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases,

More information

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation PO-CON69E Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation MSACL 6 EU Stéphane Moreau, Daisuke Kawakami, Toshikazu Minohata Shimadzu Europe GmbH, Duisburg,

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Speaker: Sky Countryman, Manager of PhenoLogix and Applied Technologies, Phenomenex Webinar Host:

More information

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis A Fast and Sensitive LC/MS/MS Method for the Quantification and Confirmation of 3 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine Samples Cliquid Software for Routine LC/MS/MS Analysis

More information

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization PO-CON1773E Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization ASMS 2017 ThP-086 Marc FERNANDEZ 1, Aurore JAFFUEL 1, Fanny DAYOT

More information

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for

More information

Dienes Derivatization MaxSpec Kit

Dienes Derivatization MaxSpec Kit Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

Author. Introduction. Abstract

Author. Introduction. Abstract Simultaneous Measurement of Sirolimus and Tacrolimus Concentrations in Blood by Semi-Automated Extraction and Liquid Chromatography-Electrospray Ionization Mass Spectrometry Application Author Gary L.

More information

SCIEX Vitamin D 200M Assay for the Topaz System

SCIEX Vitamin D 200M Assay for the Topaz System The First FDA-Cleared LC-MS/MS Assay for Vitamin D SCIEX Vitamin D 200M Assay for the Topaz System The first FDA-cleared LC-MS/MS assay for Vitamin D Vitamin D is an important building block for human

More information

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1 Development of an SPE-LC/MS/MS Assay for the Simultaneous Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid in Support of Alzheimer s Research Dr. Erin E. Chambers Waters Corporation Presented

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

Key Advantages of Comprehensive Cannabis Analysis

Key Advantages of Comprehensive Cannabis Analysis Comprehensive Cannabis Analysis: Pesticides, Aflatoxins, Terpenes, and High Linear Dynamic Range Potency from One Extract Using One Column and One Solvent System Robert Di Lorenzo 1, Diana Tran 2, KC Hyland

More information

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1 Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications dr. Jan Srbek, HPST Page 1 Major LC-MS Clinical Applications Steroids/Endocrinology Vitamin D Testosterone, Estradiol

More information

LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright

LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright SEALS Prince of Wales Hospital Randwick, NSW Clinical Chemistry From an Analytical Chemist Perspective How do you test

More information

Highly sensitive simultaneous quantitative analysis of estrone and equilin from plasma using LC/MS/MS

Highly sensitive simultaneous quantitative analysis of estrone and equilin from plasma using LC/MS/MS PO-CON1746E Highly sensitive simultaneous quantitative analysis of estrone and equilin from plasma using LC/MS/MS ASMS 2017 MP-677 Ashutosh Shelar, Shailendra Rane, Shailesh Damale, Rashi Kochhar, Purshottam

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer Overview Increased selectivity is achieved in quantitative analysis by using MS 3. The

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Towards High Resolution MS in Regulated Bioanalysis

Towards High Resolution MS in Regulated Bioanalysis Towards High Resolution MS in Regulated Bioanalysis Benno Ingelse MSD 3 rd EB focus meeting June 12 th 13 th Brussels, Belgium Contributors Gary Adamson Ken Anderson Kevin Bateman Cynthia Chavez-Eng Inhou

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Modernizing the Forensic Lab with LC-MS/MS Technology

Modernizing the Forensic Lab with LC-MS/MS Technology Modernizing the Lab with LC-MS/MS Technology Innovative SCIEX Analytical Tools for the Rapid Identification of Drugs of Abuse in Samples Oscar G. Cabrices 1, Holly McCall 1, Xiang He 1, Alexandre Wang

More information

Quantification of Budesonide Using UPLC and Xevo TQ-S

Quantification of Budesonide Using UPLC and Xevo TQ-S Tirupateswara Rao B., Sudarshan Mantha, and Gopal Vaidyanathan Waters India MS Application Laboratory, Bangalore, India A P P L I C AT ION B E N E F I T S This work demonstrates the benefits of the Regulated

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Mass Spectrometry Made Simple for Clinical Diagnostic Labs Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics

More information

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST

More information

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary

More information

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling

More information

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin LOGO Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin Rapid Quantification of Tilidine, Nortilidine and Bisnortilidine in Urine

More information

Vitamin D3 and related compounds by ESI and APCI

Vitamin D3 and related compounds by ESI and APCI Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate

More information

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo

More information

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis Application Note AN890 Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Page Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Prior to LC/MS-MS

More information

Meeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London]

Meeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London] Meeting the LC-MS needs of a highthroughput clinical laboratory April 18 th 10:00 [New York]/ 15:00 [London] Meeting the LC-MS Needs of a High-Throughput Clinical Chemistry Laboratory With examples from

More information

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1). Application LCMS-8040 Simultaneous determination of 11 steroids and Vitamin D2/D3 in human serum using LC/MS/MS - Introduction Quantification of endogenous hormonal steroids and their precursors is essential

More information

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Christophe Deckers, M.Sc. Sample prep Application Scientist Types of ``Interferences``

More information

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA The Utilization of Novel Platform in a LC-MS/MS Workflow for the Analysis of Vitamin D, Testosterone, Immunosuppressants, Chemotherapeutics and Cortisol Dayana Argoti, Kerry Hassell, Sarah J. Fair, and

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization.

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization. Application Note AN857 Ultra-Sensitive Method for the Determination of 1,25 di-oh Vitamin D2 and 1,25 di-oh Vitamin D3 Page 1 Ultra-Sensitive Method for the Determination of 1,25 di-oh Vitamin D2 and 1,25

More information

Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines

Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines Alec Saitman Ph.D., DABCC (CC, TC) Director Special Chemistry and Toxicology Providence Regional Laboratories Disclosures None

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

The New 6495 Triple Quadrupole LC/MS

The New 6495 Triple Quadrupole LC/MS The New 6495 Triple Quadrupole LC/MS Experience A New Level of Confidence Martin Haex Product Specialist MS and Automation 1 Overview of Topics The New 6495 QQQ LC/MS Technology Innovations Quantitation

More information

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after single oral administration to healthy Japanese volunteers Authors: Masaya Munekage, Hiroyuki Kitagawa, Kengo Ichikawa,

More information

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual Page 1 / 15 25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual ZV-3046-0200-10 200 Page 2 / 15 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...

More information

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Abstract This study demonstrates a sensitive, rapid and reliable research

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Measuring Lipid Composition LC-MS/MS

Measuring Lipid Composition LC-MS/MS Project: Measuring Lipid Composition LC-MS/MS Verification of expected lipid composition in nanomedical controlled release systems by liquid chromatography tandem mass spectrometry AUTHORED BY: DATE: Sven

More information

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode Application Brief Biomedical Authors Melissa Churley Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa

More information

Performance of an ultra low elution volume 96-well plate

Performance of an ultra low elution volume 96-well plate Performance of an ultra low elution volume 96-well plate Claude R. Mallet, Ziling Lu, Jeff R. Mazzeo, Uwe D. Neue Waters Corporation PittCon 2003 March 10-14 2003 Orlando, Florida Today s Challenges Faced

More information

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis Application Note AN842.V. Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS Analysis Page Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS

More information

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual Page 1 / 12 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual ZV-4027-0500-10 500 2-8 C Page 2 / 12 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...

More information

LCMS Vitamin D3 Method development

LCMS Vitamin D3 Method development LCMS-85 Vitamin D3 Method development Background Vitamin D3 Analysis is in demand in SAP region especially in Singapore and India Clinical Diagnostics and Clinical Research is demanding this application

More information

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:

More information

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent

More information

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods Application Note Food Testing & Agriculture Authors Nick Byrd and Danielle Sweeney Campden BRI Gloucestershire UK

More information

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS Jean-Daniel Berset 1 and André Schreiber 2 1 Water and Soil Protection Laboratory,

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column Erin E. Chambers and Kenneth J. Fountain Waters Corporation, Milford, MA, USA

More information

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a Supplementary Information Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a High-throughput Targeted Metabolomics Approach Nanyang Yu, Si Wei, *, Meiying Li, Jingping

More information

Abstract. Introduction

Abstract. Introduction A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue

More information

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS FORENSICS AND TOXICOLOGY ANALYSIS DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS Solutions for Your Analytical Business Markets and Applications

More information

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Application Note Forensics, Workplace Drug Testing Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Authors Fred Feyerherm and Anthony Macherone Agilent Technologies, Inc.

More information

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS Application Note Forensic Analysis Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS Authors Joan Stevens and Limian Zhao Agilent Technologies,

More information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Joanne Mather, Steve Cubbedge, Debadeep Bhattacharya, and Robert S. Plumb Waters Corporation, Milford, MA, U.S. A P P L

More information

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine PO-CON737E A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine ASMS 7 WP 353 Shao Hua Chia ; Zhi Wei Edwin Ting ; Daisuke Kawakami

More information

LC/MS/MS Analysis of Metabolites of Synthetic Cannabinoids JWH-018 and JWH-073 in Urine

LC/MS/MS Analysis of Metabolites of Synthetic Cannabinoids JWH-018 and JWH-073 in Urine Abstract A liquid chromatographic method was developed to resolve a comprehensive set of metabolites of JWH-018 and JWH-073. In addition to the chromatographic analysis method, an extraction method was

More information

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

LC-MS/MS Solutions for Comprehensive Cannabis Analysis MODERN CANNABIS LC-MS/MS ANALYSIS TOTAL SOLUTION LC-MS/MS Solutions for Comprehensive Cannabis Analysis PIONEERING YOUR ANALYTICAL TESTING REQUIREMENTS Your Partner for LC-MS/MS Solutions for Cannabis

More information

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc. SAMHSA-Compliant LC/MS/MS Analysis of 11-nor-9-carboxy-D 9 - Tetrahydrocannabinol in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 Application Note Forensic Toxicology Authors Irina

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS UCT Part Numbers CSXCE106 Clean Screen XCEL I 130mg / 6mL SPE Cartridge SPHACE5001-5 Select

More information

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Power of QTRAP Systems for Identification and Confirmation of Degradation Products Dilip Reddy 1, Chandra Sekar

More information

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18 Analyze Barbiturates in Urine with Agilent 6 LC/MS/MS and Poroshell EC-C8 Application ote Forensic Toxicology Authors Elijah Steinbauer and Pat Friel Toxicology Laboratory at the Veterans Administration

More information

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices

More information

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology ANSWERS FOR SCIENCE. KNOWLEDGE FOR LIFE. Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology Baljit Ubhi Ph.D ASMS Baltimore, June 2014 What is Metabolomics? Also

More information

The Raptor HILIC-Si Column

The Raptor HILIC-Si Column The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution

More information

Update on the Development of a Sensitive, Accurate, and User- Friendly Method for the Direct Determination of 3-MCPD 3

Update on the Development of a Sensitive, Accurate, and User- Friendly Method for the Direct Determination of 3-MCPD 3 Update on the Development of a Sensitive, Accurate, and User- Friendly Method for the Direct Determination of 3-MCPD 3 Esters J. D. Pinkston, P.J. Stoffolano, P. Y. Lin The Procter & Gamble Company, Winton

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS UCT Part Numbers SSHLD063 Styre Screen HLD 60 mg, 6 ml column SPHPHO6001-5 Select ph Buffer Pouches 100 mm Phosphate

More information

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification Accurate, Reproducible, Metabolomics Studies The word metabolome refers to the complete set of small molecule metabolites arising

More information

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives Lieve Dillen Drug Safety Sciences Analytical Sciences, Non-regulated Bioanalysis Presentation outline

More information

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology Ultra sensitive quantitative performance Unmatched quantitative performance for the most challenging analyses The Agilent 6490 Triple

More information

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research TEHNIL NOTE 64969 Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research uthors Kristine Van Natta, Neloni Wijeratne, laudia Martins Thermo Fisher Scientific,

More information

Immunosuppressants by LCMSMS. Grant Moore Toxicology

Immunosuppressants by LCMSMS. Grant Moore Toxicology Immunosuppressants by LCMSMS Grant Moore Toxicology CHLabs Past experience of Immunosuppressant TDM Azathioprine metabolites been tested for >5 years Initially two HPLC methods, TGN and MMP Two different

More information

Screening and Speciation of Raw and Processed Meat Products

Screening and Speciation of Raw and Processed Meat Products vmethod Application for Food Testing Screening and Speciation of Raw and Processed Meat Products A Selective and Robust LC-MS/MS Method for Multiple Meat Speciation and Authentication on the QTRAP 4500

More information

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN Jon W. Wong U.S. Food and Drug Administration Center for Food Safety and Applied Nutrition American Council of Independent Laboratories

More information

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.

More information

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products Johan Lindholm, Anna Wiernik, Birgitta Grandin, Margareta Curvall Swedish Match

More information