M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME
|
|
- Sheila Norris
- 5 years ago
- Views:
Transcription
1 M-SERIES Modular Femoral Stem AN ACCURATE MATCH EVERY TIME
2 54 Extension 114 Flexion High How do you ensure optimal post-operative joint stability? MECHANICAL RANGE OF MOTION Cup Position: 45 degrees abduction, 20 degrees anteversion 5,6 Low Joint stability can be affected by many factors, including offset and leg length. When the selected primary stem provides adequate leg length but the joint requires additional offset, the concern is potential post-operative dislocation. Do you sacrifice leg length or offset? With the AcuMatch M-Series, you sacrifice neither. The M-Series uncouples offset and leg length, providing surgeons a unique way to restore joint stability in complex total hip arthroplasty. Leg length and offset challenges are easily overcome by selecting from two offsets, each with multiple vertical height options. 41.2mm 41.2mm 36.2mm THE NECK SEGMENT High and low offset necks predictably restore normal anatomy. 1,2,3,4 Length 25mm 35mm Multiple vertical height options provide for leg length adjustment. Machined neck flats decrease neck cross section resulting in an increase in range of motion. 5,6,7,8 Adjust leg length without affecting offset Adjust offset without affecting leg length Low Plasticity Burnishing increases fatigue strength of neck segment by more than 30 percent. 14
3 How do you deal with unpredictable bone loss? 100% INTERCHANGEABILITY Nothing is routine about revision total hip surgery. It is an art. Frequently, unpredictable bone loss results from retrieval of the previously implanted stem. What do you do? The AcuMatch M-Series patented three-segment stem design* gives you more than 33,000 possible neck/metaphyseal/stem constructions. Customize your solutions to a wide range of proximal bone-loss situations. METAPHYSEAL FLARE SIZES L M S XS THE METAPHYSEAL SEGMENT Trapezoidal shape provides excellent rotational stability for proximal loading and ensures greater bone surface contact. 9 Optimized interference fit and 1mm of pure titanium plasma spray achieve the goal of biologic attachment. Available in diameters of 21-31mm and x-small (21, 23 and 25mm only), small, medium and large flare options. Calcar replacing segments are available for instances where the medial flare of the metaphysis is deficient. PROXIMAL/DISTAL MISMATCH *Combined with Exactech s five femoral head lengths A B A: Smallest stem coupled with largest metaphyseal segment B: Largest stem coupled with smallest metaphyseal segment
4 CROSS SECTION OF STEM SEGMENT Longitudinal flutes provide rotational stability How do you establish neck version when using a long curved stem? In some patients, the bow of the femur is lateral. In others, the acetabulum is slightly anteverted or retroverted. If you need a long curved stem for a patient with atypical anatomy, do you choose neck version or stem placement? With the M-Series, you don t have to choose. Stem segment rotated to match anatomy without affecting neck version The M-Series allows independent neck version and stem placement to minimize the potential for femoral fractures and post-operative dislocation. THE STEM SEGMENT Sharp flutes provide a solid fit in the canal resulting in rotational stability. Infinite placement of neck segment Coronal slot and patented distal tip geometry decrease the incidence of thigh pain. 10 Forged titanium more closely matches the modulus of elasticity of bone.
5 What do you want most from your prosthesis? Confidence in design and construction is an important factor in prosthesis selection. Exactech optimized the AcuMatch M-Series design using Finite Element Analysis and extensive mechanical testing. Its taper integrity and strength have been validated at a respected independent laboratory. 11 Testing including bending and torsion simulated physiological loading which represented activities of daily living. 12,13 The results categorized taper wear as mild at loads of 6.4 times body weight. Percentage of damage area was categorized as mild with only 5.9 percent to 7 percent of total taper surface area affected. 12,13 Continuous product improvement is a priority at Exactech, and when new technology was identified that could enhance the fatigue strength of metals, the M-Series was selected as a logical first application. Low Plasticity Burnishing (LPB) is a patented process that increases the fatigue strength of the M-Series neck segment by more than 30 percent. 14 From joint stability to bone loss to atypical anatomy, the AcuMatch M-Series is the answer for difficult surgical situations. Load (lbs) Finite Element Analysis of M-Series Taper M-SERIES NECK FATIGUE STRENGTH 14 M-Series Neck featuring LPB Technology Fatigue Strength (approx lbs.) per ASTM E ASTM Standard - Femoral Prosthesis Head / Neck Region Fatigue Strength per ASTM F Cycles (millions) REFERENCES Medical illustrations 2002 Neill Biomedical Art Co. 1. Davey JR, O Connor DO, Burke DW, Harris WH. Femoral component offset. J Arthroplasty Feb;8(1): Oh I, Harris WH. Anatomic basis of femoral component design for total hip replacement. Proceedings of the 24th Annual Meeting of the Orthopaedic Research Society, Dallas, Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br Jan;79(1): Robinson RP. Evaluation of offset variation in 192 consecutive hips. Unpublished data. 5. Amstutz HC, Lodwig RM, Schurman DJ, Hodgson AG. Range of motion studies for total hip replacements. Clin Orthop Relat Res Sep;(111): Krushell RJ, Burke DW, Harris WH. Range of motion in contemporary total hip arthroplasty. J Arthroplasty Jun;6(2): Vaughn BK. Management of dislocation in total hip arthroplasty. Operative Techniques in Orthopaedics Oct;5(4): Yamaguchi M, Akisue T, Bauer TW, Hashimoto Y. The spatial location of impingement in total hip arthroplasty. J Arthroplasty Apr;15(3): Joshi MG, Advani SG, Miller F, Santare MH. Analysis of a femoral hip prosthesis designed to reduce stress shielding. J Biomech Dec;33(12): Petty W. Thigh pain following cementless total hip implantation addressed by new femoral design. Orthopedic: Special Edition. Vol. 2, No Postak PD. The Orthopaedic Research Laboratories, Cleveland, OH, May Krygier JJ, Dujovne AR, Bobyn JD. Fatigue behavior of titanium femoral hip prosthesis with proximal sleeve-stem modularity. J Appl Biomater. 1994;5(3): Bobyn JD, Dujovne AR, Krygier AR, Young DL. Surface analysis of the taper junctions of retrieved and in-vitro tested modular prosthe ses. In (Morrey BF, ed): State-of-the-Art in Total Hip Arthroplasty. Raven Press, Ltd., New York, 1993, pp Data on file at Exactech, Inc EXACTECH, INC. ISO CERTIFIED EXACTECH Rev. B AcuMatch M-Series 0309 U.S. Pat. # 5,152,799, 6,319,286, 6,911,048. European Patent # Other foreign patents pending.
Continuing the Tradition. VerSys Heritage Hip System
Continuing the Tradition VerSys Heritage Hip System Heritage Following the Tradition The low-friction hip prosthesis developed by Sir John Charnley has more than a 20-year history of outstanding results.
More informationZimmer Segmental System
Zimmer Segmental System Simple solutions for solving complex salvage cases A Step Forward The Zimmer Segmental System is designed to address patients with severe bone loss associated with disease, trauma
More informationPLR. Proximal Loading Revision Hip System
PLR Proximal Loading Revision Hip System The PLR splined revision stem is designed to recreate the natural stresses in the revised femur, where proximal bone may be compromised. PLR Hip System Design Considerations
More informationThe Spatial Location of Impingement in Total Hip Arthroplasty
The Journal of Arthroplasty Vol. 15 No. 3 2000 The Spatial Location of Impingement in Total Hip Arthroplasty Motoi Yamaguchi, MD, PhD,* Toshihiro Akisue, MD, PhD,* Thomas W. Bauer, MD, PhD,* and Yasushi
More informationADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY
E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless
More informationDesign Rationale. ECHELON Primary Hip System
Design Rationale ECHELON Primary Hip System ECHELON Primary Total Hip System Addressing clinical issues of cementless hip arthroplasty Cementless total hip arthroplasty has provided a proven method of
More informationEMPERION Modular Hip System was designed in conjunction with: Robert Barrack, MD St. Louis, MO. Mathias Bostrom, MD New York, NY
Design Rationale EMPERION Modular Hip System was designed in conjunction with: Robert Barrack, MD St. Louis, MO Mathias Bostrom, MD New York, NY Robert Bourne, MD, FRCS (C) London, Ontario Dermot Collopy,
More informationZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty
ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE Surgical Technique for Revision Hip Arthroplasty A MULTITUDE OF OPTIONS Several fixation options are offered within the ZMR Hip System. Spout, Cone, and
More informationArcos Modular Femoral Revision System
Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the
More informationReaching new heights. Comprehensive. Efficient. Simple.
Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation
More informationStability without compromise. Epsilon Durasul Constrained Insert
Stability without compromise Epsilon Durasul Constrained Insert History of Dislocation and Constrained Acetabular Inserts The Need for a Better Solution The Problem Dislocation is the second most common
More informationZMR Crossover Instruments. Abbreviated Surgical Technique
ZMR Crossover Instruments Abbreviated Surgical Technique ZMR Crossover Instruments Surgical Technique Introduction ZMR Crossover Instruments facilitate the combination of any Porous Proximal Body with
More informationZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME
ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty Surgical Technique IMAGE TO COME ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty Introduction The ZMR Over-the-Junction (OTJ)
More informationClinical Evaluation Surgical Technique
Clinical Evaluation Surgical Technique Table of Contents EMPERION Specifications 3 EMPERION Surgical Technique 9 EMPERION Catalog 18 Nota Bene: This technique description herein is made available to the
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationEnhancing stability and increasing range of motion. Metasul LDH Large Diameter Head
Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that
More information9800 Metric Blvd. Austin, Texas
rev. A Encore Orthopedics, Inc. 1998 www.encoremed.com 9800 Metric Blvd. Austin, Texas 78758 512-832-9500 1 contents How to use the Foundation Hip 1 2 Plan your approach Select your hardware Preparing
More informationOne system for all revision types
Design Rationale 1 Introduction Revisions today are anything but routine. As more patients have their first total hip at a younger age, it s becoming common for many to have multiple revision surgeries
More informationRestoration Modular Revision Hip System. Choice Matters
Restoration Modular Revision Hip System Choice Matters Restoration Modular Revision Hip System The Restoration Modular Revision Hip System combines successful designs with the latest technology to answer
More informationProduct Rationale. Where Strength and Modularity Connect
Product Rationale Where Strength and Modularity Connect 2 ReClaim Modular Revision Hip System Advanced Strength 1 Advanced Strength Over 600 million cycles of testing 1 Advanced Fixation Advanced Instrumentation
More informationRevision. Hip Stem. Surgical Protocol
U2 TM Revision Hip Stem Surgical Protocol U2 Revision Hip Stem Table of Contents Introduction... 1 Preoperative Planning... 2 Femoral Preparation... 3 Trial Reduction... 5 Implant Insertion... 6 Ordering
More informationPROFEMUR Total Hip System P R O D U C T C A T A L O G
PROFEMUR Total Hip System P R O D U C T C A T A L O G The PROFEMUR Total Hip System Superior Product Modular Neck Technology Seat stem in best possible bone stock Control leg length, offset, and version
More informationPreoperative Planning. The primary objectives of preoperative planning are to:
Preoperative Planning The primary objectives of preoperative planning are to: - Determine preoperative leg length discrepancy. - Assess acetabular component size and placement. - Determine femoral component
More informationRECLAIM REVISION HIP SYSTEM
RECLAIM REVISION HIP SYSTEM Where Strength and Modularity Connect DESIGN RATIONALE System Overview RECLAIM Modular Revision Hip System WHERE STRENGTH & MODULARITY CONNECT 2 Offset Options Proximal Body
More informationSpecifications guide ECHELON. Hip System
Specifications guide ECHELON Hip System Primary and revision porous implants Porous coating ROUGHCOAT porous coating increases the friction between the implant and bone, improving implant stability and
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationCAUTION: Ceramic liners are not approved for use in the United States.
Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of
More informationSURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS
SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments
More informationCLS Brevius Stem with Kinectiv Technology
CLS Brevius Stem with Kinectiv Technology The Next Chapter in 27 Years of CLS Spotorno Stem History: Flexibility 2 CLS Brevius Stem with Kinectiv Technology Product Information Introduction Through independent
More informationCement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter
Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished
More informationwhat you is back within LOVE arm s reach find out why the exactech shoulder may be right for you
TOTAL shoulder REPLACEMENT what you is back within LOVE arm s reach find out why the exactech shoulder may be right for you how does your shoulder work? The shoulder is the most mobile joint in the body.
More informationThe Leader in Orthopaedic Innovation
The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationEncina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA
Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA 94065 info@stinsonortho.com www.stinsonortho.com Table of Contents Introduction 3 Features 4 Surgical Technique 5 Preoperative
More informationAML Hip System. Design Rationale/ Surgical Technique
AML Hip System Design Rationale/ Surgical Technique Design Rationale Evolution In 1977, DePuy Synthes Companies introduced the original cementless total hip. The AML Hip launched in order to solve one
More informationSURGICAL TECHNIQUE. Alpine Cementless Hip Stem
SURGICAL TECHNIQUE Alpine Cementless Hip Stem The following technique is a general guide for the instrumentation of the Alpine Cementless Hip Stem. It is expected that the surgeon is already familiar with
More informationAnswer. Hip System Design Features:
Table of Contents Alliance Revision Balance Stanmore Bio-Moore II Taperloc Mallory-Head P.O. Box 587, Warsaw, IN 46581-0587 574.267.6639 2003 Biomet, Inc. All Rights Reserved web site: www.biomet.com email:
More informationEXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM
EXACTECH KNEE Operative Technique ADDENDUM Metaphyseal Cones Surgeon focused. Patient driven. TM TABLE OF CONTENTS INTRODUCTION...1 DESCRIPTION...1 DETAILED OPERATIVE TECHNIQUE Initial Preparation and
More informationVersys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis
Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis Surgical Technique Traditional Design. Innovative Features. Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis 1 Versys Advocate
More informationS U R G I C A L T E C H N I Q U E
SURGICAL TECHNIQUE RECOVERY FUNCTION SURVIVORSHIP DePuy believes in an approach to total hip replacement that places equal importance on recovery, function and survivorship. The DePuy PROXIMA Hip System
More informationREVISING THE DEFICIENT PROXIMAL FEMUR
REVISING THE DEFICIENT PROXIMAL FEMUR by David Mattingly, Boston, MA Joseph McCarthy, Boston, MA Benjamin E. Bierbaum, Boston, MA Hugh P. Chandler, Boston, MA Roderick H. Turner, Boston, MA Hugh U. Cameron,
More informationOptimum implant geometry
Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationTrabecular Metal Acetabular Revision System Cemented Constrained Liner
Trabecular Metal Acetabular Revision System Cemented Constrained Liner Trabecular Metal Acetabular Revision System Cemented Constrained Liner Surgical Technique The Best Thing Next to Bone... Stability
More informationTHE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation
THE NATURAL FIT Surgical Technique Hip Knee Spine Navigation MiniMAX Surgical Technique Hip Knee Spine Navigation INTRODUCTION The MiniMAX TM is a cementless anatomic stem available in 9 right sizes and
More informationMetha Short Hip Stem System
Metha Short Hip Stem System Accuracy That Stands Alone Aesculap Orthopaedics Metha Short Hip Stem System Designed For Anatomic Accuracy The Metha Short Hip Stem is designed for anatomic accuracy to restore
More informationVerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement
VerSys LD/Fx Cemented and Press-Fit Hip Prostheses Surgical Technique IMAGE TO COME Versatile solutions for total and partial hip replacement VerSys LD/Fx Cemented and Press-Fit Hip Prostheses VerSys
More informationThe bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series
The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology porous primary hip series BI-METRIC XR SERIES implant technology The Bi-Metric XR Hip Series
More informationAnterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life
Anterior Approach Surgical Technique Paragon Stem System enabling people to enjoy life Contents Pre-Operative Planning... 2 Suggested Templating Method... 2 Surgical Technique... 3 Surgical Approach...
More informationFollowing a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique
Following a tradition of success VerSys Heritage Primary Hip Prosthesis Surgical Technique VerSys Heritage Primary Hip Prosthesis 1 Surgical Technique For VerSys Heritage Primary Hip Prosthesis Dennis
More informationAUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique
AUTOBLOQUANTE AUTOBLOQUANTE Product Rationale Surgical Technique AUTOBLOQUANTE The Product of Long-Term Clinical Experience The AUTOBLOQUANTE femoral component is a direct descendant of the original straight
More informationBi-Polar 22.2mm & 28mm System - Operative technique
Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs
More informationEXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.
EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical
More information*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information
Product Information *smith&nephew SL-PLUS Cementless Femoral Hip System First Came the Philosophy to develop a universal hip system that could be used in almost every indication, immaterial to the patient
More informationEMPERION Modular Hip System Surgical Technique
Surgical Technique Introduction The EMPERION Modular Hip System is a versatile system that can be used for primary and revision hip surgeries. Using modular proximal bodies, this system addresses the proximal
More informationBone Preservation Stem
TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
More informationLPS SYSTEM POCKET GUIDE
LPS SYSTEM POCKET GUIDE Implants Procedural Uses Instruments & Trials L P S Limb Preservation System L P S Limb Preservation System The purpose of this document is to review the LPS (Limb Preservation
More informationMetaFix Cementless Total Hip Replacement Product overview
MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix
More informationVerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique
VerSys Fiber Metal Taper Hip Prosthesis Surgical Technique VerSys Fiber Metal Taper Hip Prosthesis Surgical Technique 1 VerSys Fiber Metal Taper Hip Prosthesis Surgical Technique Table of Contents Preoperative
More informationZimmer M/L Taper Hip Prosthesis. Surgical Technique
Zimmer M/L Taper Hip Prosthesis Surgical Technique Zimmer M/L Taper Hip Prosthesis 1 Zimmer M/L Taper Hip Prosthesis Surgical Technique Table of Contents Preoperative Planning 2 Determination of Leg Length
More informationINTERTAN Nails Geared for Stability
Geared for stability The TRIGEN INTERTAN nail brings advanced TRIGEN nail technology to hip fractures. With a unique integrated, interlocking screw construct, TRIGEN INTERTAN nail provides all the benefits
More informationEXACTECH HIP. Operative Technique. Tapered and Splined Press-Fit Stems. Cemented Femoral Stems. Renewing Innovations. Enduring Solutions.
EXACTECH HIP Operative Technique Tapered and Press-Fit Stems Cemented Femoral Stems Renewing Innovations. Enduring Solutions. Surgeon focused. Patient driven. TM TABLE OF CONTENTS INTRODUCTION... 1 DESIGN
More informationComprehensive. Simple. Efficient.
SYNERGY Hip System Comprehensive. Simple. Efficient. It s easy to understand why SYNERGY Hip System has been used for many years and its popularity continues to increase. As a result of building on the
More informationRevision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability
J Orthopaed Traumatol () 7:1 1 DOI 1.17/s1195--15- ORIGINAL M. El-Deen S. Zahid D.T. Miller A. Nargol R. Logishetty Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant
More information1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System
Trabecular Metal Natural Cup System 1Acetabular Reaming Use progressively larger reamers to prepare the acetabulum. Hold the reamer steady in the same position in which the cup will be implanted (approximately
More informationLeg length discrepancy After Total Hip Replacement: Prevalence And impact on functional outcome
Leg length discrepancy After Total Hip Replacement: Prevalence And impact on functional outcome Dissertation Submitted for - M.ch, (Ortho) (USAIM) By; Dr. Vivek Savaskar M.S. {Orthopaedics}, Orthopaedic
More informationCementless Modular Stems By Timothy McTighe, Editor
Joint Implant Surgery & Research Foundation APRIL, 2002 JISRF Update Cementless Modular Stems By Timothy McTighe, Editor Introduction Our past November 2001 feature article reviewed and highlighted a specific
More informationHIP SYSTEM SURGICAL TECHNIQUE
HIP SYSTEM SURGICAL TECHNIQUE Introduction...2 Preoperative Planning...3 Preoperative Planning...3 Templating and Radiographs...4 Determination of Leg Length Discrepancy...5 Determining Acetabular Cup
More informationTopology optimisation of hip prosthesis to reduce stress shielding
Computer Aided Optimum Design in Engineering IX 257 Topology optimisation of hip prosthesis to reduce stress shielding S. Shuib 1, M. I. Z. Ridzwan 1, A. Y. Hassan 1 & M. N. M. Ibrahim 2 1 School of Mechanical
More informationCLINICAL PAPER / ORTHOPEDIC
HIP LEG LENGTH AND OFFSET Kelley T.C. and Swank M.L. (2009) Using CAS leads to more accurate positioning within the safe zone (inclination between 30 and 50, anteversion between 5 and 25 ) CAS improves
More informationR3think your options. For US distribution only.
R3think your options For US distribution only. R3think acetabular surgery It is widely accepted that total hip replacement surgery is one of the most successful procedures done today. Typically more thought
More informationArcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System
Arcos Interlocking Distal Stem Surgical Technique Addendum to the Arcos Modular Femoral Revision System One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationMetaFix. Cementless Total Hip Replacement Surgical technique
Cementless Total Hip Replacement Surgical technique Contents Operative summary Acetabular preparation Pre-operative templating Femoral neck osteotomy Femoral canal preparation Femoral punch Tapered IM
More informationHip Fracture Management. Product overview
Hip Fracture Management Product overview Hip Fracture Management Intracapsular fractures Total hip replacement (THR) can offer clinical benefits over traditional internal fixation or hemiarthroplasty solutions
More informationZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME
ZMR Porous Revision Hip Prosthesis Surgical Technique IMAGE TO COME ZMR Porous Revision Hip Prosthesis Surgical Technique 1 ZMR Porous Revision Hip Prosthesis Surgical Technique Table of Contents Preoperative
More informationShunsaku Nishihara 1, Nobuhiko Sugano 1, Takashi Nishii 1, Hisashi Tanaka 2, Hideki Yoshikawa 1, and Takahiro Ochi 1
J Orthop Sci (2003) 8:352 360 Comparison of the fit and fill between the Anatomic Hip femoral component and the VerSys Taper femoral component using virtual implantation on the ORTHODOC workstation Shunsaku
More informationTaperFill. Surgical Technique
TaperFill Surgical Technique Table of Contents Indications and Contraindications 3 TaperFill Hip Size Charts 4-5 DJO Surgical 9800 Metric Boulevard Austin, TX (800) 456-8696 www.djosurgical.com Preoperative
More informationProduct Portfolio. Consensus Knee Systems. Consensus Hip Systems
1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 info@consensusortho.com consensusortho.com Product Portfolio Consensus Knee Systems Consensus Hip Systems Product Portfolio
More informationFLH /11
FLH 225 04/11 This publication has been issued by: European Central Marketing Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel: +44 (0)1656 655221 Fax: +44 (0)1656 645454 www.biomet.com
More informationSurgical Technique r5.indd 1 12/8/10 10:36 AM
Surgical Technique The science of simplicity With more than 700,000 implantations and two and a half decades of clinical success, the Corail Total Hip System now has the most extensive experience with
More informationSurgical Technique. Unisyn Hip System
Surgical Technique Unisyn Hip System INDICATIONS AND USAGE Significantly impaired joints resulting from rheumatoid, osteo, and post-traumatic arthritis. Revision of failed femoral head replacement, hip
More informationEXACTECH HIP. Design Rationale. Neck Preserving Stem. Surgeon focused. Patient driven. TM
EXACTECH HIP Design Rationale Neck Preserving Stem Surgeon focused. Patient driven. TM Table of Contents DESIGN HISTORY AND EVOLUTION OF THE NECK PRESERVING STEM... 3 Summary of Success... 5 UNMET CLINICAL
More informationBone Conserving Hip Replacement Surgical technique
MiniHip Bone Conserving Hip Replacement Surgical technique MiniHip Contents Operative summary 4 Overview 5 Pre-operative templating 6 Operative technique 7 Neck resection 7 Femoral canal preparation 7
More informationSurgical technique MkII instrumentation
MiniHip Surgical technique MkII instrumentation Contents Operative summary 4 Overview 5 Pre-operative templating 6 Operative technique 7 1. Intra-operative templating 7 2. Neck starter awl 7 3. Curved
More informationcomprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology
comprehensive shoulder system Design Rationale Knees Hips Extremities Cement and Accessories PMI TEchnology . INTRODUCTION The Comprehensive Shoulder System is an evolutionary design based on the successful
More informationSurgical Technique. Hip System
Surgical Technique Hip System INDICATIONS FOR USE The TaperSet Hip System is designed for total or partial hip arthroplasty and is intended to be used with compatible components of the Consensus Hip System.
More informationScan Bi-Polar 22/28. Operative Technique
Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual
More informationCementless Tapered Femoral Stem Surgical technique
Cementless Tapered Femoral Stem Surgical technique Contents Operative summary 4 Pre-operative planning 5 Femoral neck osteotomy 5 Femoral canal preparation 5 Intra-medullary (IM) reamer 6 Sequential rasping
More informationStinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA
Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA 94065 info@stinsonortho.com www.stinsonortho.com Encina HA Stem Table of Contents Introduction 3 Encina HA Stem Features 4 Surgical
More informationEfficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem
Efficacy Innovation ABG II Cemented Stem Brochure Surgical Protocol 2 The ABG Hip System The ABG hip implant range has been progressively extended and enhanced over the past years, harnessing extensive
More informationEXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION
EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION SINCE 1983 PREOPERATIVE PLANNING EXPLANTATION OPTIONS the cement from inside the cement canal until the bone/ cement bond
More informationCementless Tapered Femoral Stem Surgical technique
Cementless Tapered Femoral Stem Surgical technique Contents Operative summary 4 Pre-operative planning 5 Femoral neck osteotomy 5 Femoral canal preparation 5 Intra-medullary (IM) reamer 6 Sequential rasping
More informationRange of Motion After Total Hip Arthroplasty: Experimental Verification of the Analytical Simulator
Range of Motion After Total Hip Arthroplasty: Experimental Verification of the Analytical Simulator Branislav Jaramaz, Constantinos Nikou, David Simon and Anthony DiGioia III CMU-RI-TR-97-09 Robotics Institute
More informationArcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique
Arcos Modular Femoral Revision System Broach and Calcar Proximal Bodies Surgical Technique Table of Contents Pre-operative Planning...2 Patient Positioning and Surgical Approach...2 Removal of a Cemented
More informationACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE
ACTIS TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE APPROACH ACTIVE PATIENTS WITH CONFIDENCE The ACTIS Total Hip System is the first DePuy Synthes Companies of Johnson & Johnson
More informationCONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM
CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM Instructions for Use (IFU) IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR
More informationBone Bangalore
Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,
More informationRESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM
RESTORATION MODULAR REVISION HIP SYSTEM Surgical Protocol Restoration Modular Cone Body/Fluted & Plasma Distal Stem Femoral Components Using the Restoration Modular Instrument System Restoration Modular
More informationTri-Lock Bone Preservation Stem
Tri-Lock Bone Preservation Stem Clinical Results of the Tri-lock BPS Femoral Stem at One Year Follow-Up William L. Healy, M.D. Lahey Clinic Medical Center Burlington, Massachusetts Introduction Cementless
More informationRevision Modular Stem type RMD
Revision Modular Stem type RMD Cementless Femoral Hip Joint Components Revision Systems Implant Description Surgical Technique Instrumentation Set Catalogue Preface Revision modular stem (RMD) is a solution
More informationUTF Stem. reduced. Surgical Protocol
UTF Stem TM reduced Surgical Protocol Table of Contents Surgical Protocol Device... Preoperative Planning and Templating... Femoral Osteotomy... Femoral Canal Accessing... Canal Reaming... Canal Broaching...
More information