Low Bend Distal Tibia Plates
|
|
- Caren Rose
- 5 years ago
- Views:
Transcription
1 Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
2 Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia Plates 2 AO Principles 4 Indications 5 Surgical Technique Preparation 6 Reduction 7 Plate Insertion 8 Screw Insertion 13 Implant Removal 17 Product Information Implants 18 Instruments 19 Set Lists 22 MR Information The 3.5 mm LCP Low Bend Medial Distal Tibia Plate System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration, or image artifact in the MR environment. The safety of the 3.5 mm LCP Low Bend Medial Distal Tibia Plate System in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. Image intensifier control 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 1
3 3.5 mm LCP Low Bend Medial Distal Tibia Plates The 3.5 mm LCP Low Bend Medial Distal Tibia Plate is part of the Depuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The Combi holes in the LCP Plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi holes provide the flexibility of axial compression and locking capability throughout the length of the plate shaft. Fixation with the 3.5 mm LCP Low Bend Medial Distal Tibia Plate has many similarities to traditional plate fixation methods, with a few important improvements. Locking screws provide the ability to create a fixed-angle construct while using standard AO plating techniques. Locking capability is important for fixed-angle constructs in osteopenic bone or multifragment fractures where screw purchase is compromised. These screws do not rely on plate-to-bone compression to resist patient load, but function similarly to multiple, small, angled blade plates. 2 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
4 3.5 mm LCP Low Bend Medial Distal Tibia Plates Plate features Head of plate is low profile for minimal prominence on medial malleolus 3.5 mm cortex and 4.0 mm cancellous bone screws sit flush with plate in the nonlocking portion of distal Combi holes to minimize screw prominence Rounded edges to minimize soft tissue irritation Limited-contact shaft profile Available in stainless steel or titanium* Four to fourteen Combi holes in the shaft Combi holes in the shaft and head accept the following: 3.5 mm cortex screws 3.5 mm locking screws 4.0 mm cancellous bone screws Six round locking holes in the head accept the following: 2.7 mm cortex screws 3.5 mm cortex screws 3.5 mm locking screws 4.0 mm cancellous bone screws Two distal Combi holes Distal K-wire hole for plate placement (2.0 mm maximum diameter) Three distal locking screws diverge across subchondral bone and are parallel to joint *Implant-quality 316L stainless steel or titanium alloy (Ti-6Al-7Nb). 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 3
5 AO Principles AO PRINCIPLES In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation. 1,2 In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation 1, 2. 4_Priciples_03.pdf :08 Anatomic Anatomic reduction reduction Fracture Fracture reduction reduction and and fixation fixation to to restore restore anatomical anatomical relationships. relationships. 1 2 Stable Stable fixation fixation Fracture Fracture fixation fixation providing providing absolute absolute or relative or relative stability, stability, as required as by the required patient, by the the injury, patient, and the the injury, personality and the personality of the fracture. of the fracture. Early, active mobilization Early Early and and safe safe mobilization and rehabilitation of of the injured part and and the the patient as as a whole. 4 3 Preservation Preservation of of blood blood supply supply Preservation Preservation of of the the blood blood supply supply to to soft soft tissues tissues and and bone bone by by gentle reduction gentle reduction techniques techniques and and careful careful handling. handling. 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg, New York: Springer-Verlag; Rüedi TP, RE Buckley, CG Moran. AO Principles of Fracture Management. 1 Müller ME, M Allgöwer, R Schneider, H Willenegger. Manual of Internal 2nd ed. Stuttgart New York: Thieme; Fixation. 3rd ed. Berlin Heidelberg New York: Springer Rüedi TP, RE Buckley, CG Moran. AO Principles of Fracture Management. 2nd ed. Stuttgart, New York: Thieme DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
6 Indications The Synthes LCP Distal Tibia Plates are intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal tibia, as a part of the Synthes Small Fragment LCP System. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 5
7 Preparation 1 Preparation Required set Small Fragment LCP Instrument and Implant Set, with self-tapping screws or Small Fragment LCP Instrument and Titanium Implant Set, with self-tapping screws Optional sets Bone Forceps Set M Small Battery Drive Set Large Distractor Set Optional instruments * Articulated Tension Device Bending Iron Plate-Bending Press Warning: The direction of locking screws is predetermined by the design of the plate. If manual contouring is necessary, verify new screw angles using the screw placement verification technique on page 10. Complete the preoperative radiographic assessment and prepare the preoperative plan. Determine plate length and instruments to be used. Position the patient supine on a radiolucent operating table. Note: For information on fixation principles using conventional and locked plating techniques, please refer to the Small Fragment Locking Compression Plate (LCP) Technique Guide. *Found in the Basic Instrument Set, for LC-DCP and DCP (115.04). 6 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
8 Reduction 2 Reduce articular surface Instruments Large Distractor Small Battery Drive Quick Coupling for K-Wires Approach An open or a percutaneous approach may be used depending on the fracture. For a percutaneous approach, make an incision to access the medial malleolus and slide the plate under the soft tissue. Reduction Note: Application of an external fixator or large distractor may facilitate visualization and reduction of the joint. Reduce the fracture fragments and confirm reduction using image intensification. Methods of stabilizing reduction include the following: Independent Kirschner wires K-wires through the plate Independent lag screws Lag screws through the plate Locking screws through the plate Locking screws do not provide interfragment compression; therefore, any desired compression must be achieved with standard lag screws. The articular fractures must be reduced and compressed before fixation of the 3.5 mm LCP Medial Distal Tibia Plate with locking screws. Precaution: To verify that independent lag screws will not interfere with plate placement, evaluate placement intraoperatively with AP and lateral fluoroscopic images. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 1
9 Plate Insertion 3 Insert plate Instrument Threaded Plate Holder Saphenous vein Saphenous nerve Percutaneous insertion For a percutaneous approach, insert the plate through the medial incision. Carefully push the plate under the soft tissue. Note: Thread a threaded plate holder into one of the distal holes as a handle for percutaneous insertion. Open insertion Open the area as necessary to expose the joint. Carefully push the plate under the soft tissue for placement on the shaft. Center the plate on the medial malleolus. Precaution: When choosing a percutaneous approach take care not to damage the saphenous nerve or saphenous vein. 8 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
10 Plate Insertion 4 Position plate and fix provisionally After plate insertion, check alignment on the bone using fluoroscopy. Make any adjustments before inserting screws. Note: This locking plate is precontoured to fit the medial distal tibia. If the plate contour is changed, it is important to check the position of the screws relative to the joint, using the screw placement verification technique. Optional instrument Push-Pull Reduction Device The plate may be temporarily held in place using any of the following options: Push-pull reduction device 4.0 mm cancellous bone screw in a distal Combi hole Standard plate-holding forceps K-wires through the plate Any of these options will allow moving the plate into final position, and will also prevent plate rotation while inserting the first locking screw. Note: Ensure proper reduction before inserting the first locking screw. Once the locking screws are inserted, further reduction is not possible without loosening the locking screws. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 9
11 Plate Insertion Optional technique: Screw placement verification Instruments mm Kirschner Wire with Thread mm Drill Bit mm Threaded Drill Guide mm Wire Sleeve Direct Measuring Device Small Battery Drive Quick Coupling for K-Wires Since the direction of the locking screw depends on the contour of the plate, final screw position may be verified with a K-wire before insertion. This becomes especially important when the plate has been manually contoured or applied near the joint. 10 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
12 Plate Insertion With the 2.8 mm threaded drill guide in the desired locking hole, insert the 1.6 mm wire sleeve into the threaded drill guide. Insert a 1.6 mm threaded K-wire through the wire sleeve and drill to the desired depth. Verify K-wire placement under image intensification to determine if final screw placement will be acceptable. Precaution: The K-wire position represents the final position of the locking screw. Confirm that the K-wire does not enter the joint. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 11
13 Plate Insertion Optional technique: Screw placement verification continued Measure for screw length by sliding the tapered end of the direct measuring device over the K-wire down to the wire sleeve. Remove the direct measuring device, K-wire and 1.6 mm wire sleeve, leaving the threaded drill guide in place. Use the 2.8 mm drill bit to drill. Remove the threaded drill guide. Insert the appropriate length locking screw. 12 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
14 Screw Insertion 5 Insert distal screws Determine the combination of screws to be used for fixation. If a combination of locking and cortex screws will be used, cortex screws should be inserted first to pull the plate to the bone. If a locking screw will be used as the first screw, ensure the plate is held securely to the bone to prevent plate rotation as the screw is locked to the plate. In distal Combi holes: For nonlocking screws, use the standard AO screw insertion technique. The two Combi holes in the plate head accept 3.5 mm cortex, 3.5 mm locking or 4.0 mm cancellous bone screws. When using a cortex or cancellous bone screw in these Combi holes, the screwhead will be recessed in the hole. For distal locking screws: Instruments mm Drill Bit mm Threaded Drill Guide StarDrive Screwdriver, T StarDrive Screwdriver Shaft, T Depth Gauge Thread the 2.8 mm threaded drill guide into a distal locking hole until fully seated. Use the 2.8 mm drill bit to drill to the desired depth. Remove the drill guide. Use the depth gauge to determine screw length. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 13
15 Screw Insertion 5 Insert distal screws continued Instruments * Torque Limiting Attachment, 1.5 Nm or Torque Limiting Attachment, 1.5 Nm, quick coupling Insert the locking screw under power, using the torque limiting attachment and the StarDrive TM Screwdriver shaft, or insert manually, using the StarDrive Screwdriver. Be sure the plate is held securely to the bone to prevent plate rotation as the screw is locked to the plate. Notes: When using the torque limiting attachment, the screw is securely locked into the plate when a click is heard. Always use a torque limiting attachment when using power with the StarDrive Screwdriver shaft. *Also available. 14 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
16 Screw Insertion Optional technique: Direct measuring with calibrated drill bits For locking screws: Instruments mm LCP Drill Guide mm Calibrated Drill Bit, quick coupling StarDrive Screwdriver Shaft, T StarDrive Screwdriver shaft, T15 Determine where locking screws will be used. Thread the 2.8 mm LCP Drill Guide into a threaded hole until fully seated. Use the 2.8 mm calibrated drill bit to drill to desired depth. Determine the screw length directly from the drill bit. Insert the screw. **Found in the Basic Instrument Set, for LC-DCP and DCP (115.04). 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 15
17 Screw Insertion 6 Insert screws in shaft If using the threaded portion of the Combi holes, repeat the steps as described for distal locking screw insertion. For nonlocking screws, use the standard AO screw insertion technique. 16 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
18 Implant Removal Optional sets Screw Removal Set Broken Screw Removal Set Unlock all screws from the plate, then remove the screws completely from the bone. This prevents simultaneous rotation of the plate when unlocking the last locking screw. If the screws cannot be removed with the screwdriver, insert the conical extraction screw with left-handed thread into the screwhead using the handle with quick coupling and loosen the locking screw by turning counterclockwise. 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 11
19 Screws Used with the 3.5 mm LCP Low Bend Medial Distal Tibia Plates Stainless Steel and Titanium 2.7 mm Cortex Screws* May be used in the distal locking holes Compresses the plate to the bone 3.5 mm Cortex Screws* May be used in the DCU portion of the Combi holes in the plate shaft Compresses the plate to the bone or creates axial compression 3.5 mm Locking Screws* Creates a locked, fixed-angle screw/plate construct Self-tapping tip Used in the locking portion of the Combi holes or in round locking holes 4.0 mm Cancellous Bone Screws* May be used in the DCU portion of the Combi holes in the plate shaft Compresses the plate to the bone or creates axial compression Fully or partially threaded shaft *Found in the Small Fragment LCP set. 18 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
20 Instruments mm Kirschner Wire with thread mm LCP Drill Guide, long for 3.5 mm LCP plates mm Drill Bit, quick coupling, 248 mm/ 95 mm calibration mm Drill Bit, quick coupling, 165 mm mm Threaded Drill Guide StarDrive Screwdriver, T15, self-retaining StarDrive Screwdriver Shaft, T15, self-retaining, quick coupling 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 19
21 Instruments Depth Gauge mm Wire Sleeve Direct Measuring Device Push-Pull Reduction Device Threaded Plate Holder, long Bending Iron, for 2.7 mm and 3.5 mm plates, 150 mm length Used with Bending Iron, for 2.7 mm and 3.5 mm plates, 150 mm length Used with DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique
22 Instruments Bending Pliers, for 2.7 mm and 3.5 mm plates Large Distractor Torque Limiting Attachment, 1.5 Nm Torque Limiting Attachment, 1.5 Nm, quick coupling 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique DePuy Synthes 22
23 3.5 mm LCP Low Bend Medial Distal Tibia Plate Sets Stainless Steel ( ) and Titanium ( ) Graphic Case Graphic Case for 3.5 mm LCP Low Bend Medial Distal Tibia Plate Implants 3.5 mm LCP Low Bend Medial Distal Tibia Plates, right Stainless Steel Titanium Holes Length (mm) mm LCP Low Bend Medial Distal Tibia Plates, left Stainless Steel Titanium Holes Length (mm) Available nonsterile or sterile-packed. Add S to catalog number to order sterile product. Note: For additional information, please refer to package insert. For detailed cleaning and sterilization instructions, please refer to or sterilization instructions, if provided. 22 DePuy Synthes 3.5 mm LCP Low Bend Medial Distal Tibia Plates Technique Guide Surgical Technique
24 Also Available Graphic Cases mm LCP Medial Distal Tibia Plate, without tab, Set Graphic Case mm Titanium LCP Medial Distal Tibia Plate, without tab, Set Graphic Case Implants 3.5 mm LCP Medial Distal Tibia Plates, without tab, right Stainless Steel Titanium Holes Length (mm) mm LCP Medial Distal Tibia Plates, without tab, left Stainless Steel Titanium Holes Length (mm) mm LCP Medial Distal Tibia Plates Right Left Holes Length (mm) mm LCP Pilon Plates Holes Length (mm) mm LCP Low Bend Medial Distal Tibia Plates Technique Guide Surgical Technique DePuy Synthes 22
25 Limited Warranty and Disclaimer: DePuy Synthes products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. Please also refer to the package insert(s) or other labeling associated with the devices identified in this surgical technique for additional information. CAUTION: Federal Law restricts these devices to sale by or on the order of a physician. Some devices listed in this surgical technique may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Not all products may currently be available in all markets. Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA Synthes USA, LLC 1101 Synthes Avenue Monument, CO To order (USA): To order (Canada): Note: For recognized manufacturer, refer to the product label. DePuy Synthes All rights reserved. DSUS/TRM/1016/1161 5/17 DV
Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.
Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia Plates
More informationLCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.
LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures. Surgical Technique This publication is not intended for distribution in the
More information3.5 mm LCP Extra-articular Distal Humerus Plate
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Extra-articular Distal Humerus Plate Surgical Technique Table of Contents Introduction 3.5 mm LCP Extra-articular Distal Humerus
More information3.5 mm LCP Olecranon Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Olecranon Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications
More information3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments
Part of the 3.5 mm LCP 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments Surgical Technique TABLE OF CONTENTS INTRODUCTION 3.5 mm LCP Low Bend Medial Distal Tibia Plate 2 Aiming Instruments
More informationLCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.
LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Technique Guide LCP Small Fragment System Table of Contents Introduction
More informationPart of the DePuy Synthes Locking Compression Plate (LCP ) System. 3.5 mm LCP Medial Proximal Tibia Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Medial Proximal Tibia Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Medial Proximal Tibia Plates 2 AO
More information2.7 mm/3.5 mm LCP Distal Fibula Plate
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 2.7 mm/3.5 mm LCP Distal Fibula Plate Surgical Technique Table of Contents Introduction 2.7 mm/3.5 mm LCP Distal Fibula Plates 2 AO Principles
More informationLong Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique
Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP Dia-Meta Volar Distal Radius Plates Surgical Technique Table of Contents Introduction LCP Dia-Meta Volar Distal Radius Plates 2 AO Principles
More information3.5 mm LCP Anterolateral Distal Tibia Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Anterolateral Distal Tibia Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Anterolateral Distal Tibia Plates
More informationOBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.
LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Surgical Technique LCP Small Fragment System This publication
More informationTechnique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.
Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal
More information3.5 mm LCP Clavicle Hook Plates
Part of the Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Clavicle Hook Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Clavicle Hook Plates 2 AO Principles 4 Indications
More information3.5 mm LCP Hook Plate
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Hook Plate Surgical Technique Table of Contents Introduction 3.5 mm LCP Hook Plate 2 AO Principles 4 Indications 5 Clinical
More information3.5 mm Locking Attachment Plate
For Treatment of Periprosthetic Fractures 3.5 mm Locking Attachment Plate Surgical Technique Table of Contents Introduction 3.5 mm Locking Attachment Plate 2 Indications 4 Surgical Technique Preparation
More information3.5 mm Clavicle Hook Plates
A Single Solution for Lateral Clavicle Fractures and Acromioclavicular Joint Dislocations 3.5 mm Clavicle Hook Plates Surgical Technique Discontinued December 2017 DSUS/TRM/1016/1126(1) Table of Contents
More information3.5 mm LCP Distal Humerus Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Distal Humerus Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Distal Humerus Plates 2 AO Principles 4 Indications
More information4.5 mm LCP Medial Proximal Tibia Plates
Part of the DePuy Synthes LCP Periarticular Plating System 4.5 mm LCP Medial Proximal Tibia Plates Surgical Technique Table of Contents Introduction 4.5 mm LCP Medial Proximal Tibia Plates 2 AO Principles
More information3.5 mm LCP Superior Anterior Clavicle Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Superior Anterior Clavicle Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Superior Anterior Clavicle Plates
More informationTechnique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.
Technique Guide 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications 3 Clinical
More informationLCP DISTAL TIBIA PLATE
LCP DISTAL TIBIA PLATE Instruments and implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Image intensifier control This description
More information3.5 mm LCP Distal Tibia T-Plates
Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Distal Tibia T-Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Distal Tibia T-Plates 2 AO Principles 4 Indications
More informationTechnique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.
Technique Guide 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 2.7 mm/3.5 mm LCP Distal Fibula Plates 2 AO Principles
More informationThe Locking Calcaneal Plate Instrument and Implant Sets
Part of the DePuy Synthes Locking Compression Plate (LCP ) System The Locking Calcaneal Plate Instrument and Implant Sets Surgical Technique Table of Contents Introduction Locking Calcaneal Plate 2 AO
More informationLCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.
LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction
More informationLCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.
LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction
More informationTechnique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.
Technique Guide 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Proximal Humerus Plate 2 AO Principles
More informationTechnique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.
Technique Guide LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction LCP Distal Fibula Plates 2 AO Principles 4 Indications 5 Surgical Technique
More informationLCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.
LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. Technique Guide This publication is not intended for distribution in the USA. Instruments
More informationFor Distal Femur Fractures. 95º Condylar Plate. Quick Reference Chart
For Distal Femur Fractures 95º Condylar Plate Quick Reference Chart 95 Condylar Plate. Quick reference chart for distal femur fractures. Insert guide wires Fix condylar fragments with 6.5 mm cancellous
More informationLCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.
LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved
More information2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates
For Fragment-Specific Fracture Fixation With Variable Angle Locking Technology 2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates Surgical Technique Table of Contents Introduction 2.4 mm Variable
More informationCannulated Pediatric Osteotomy System (CAPOS)
A Single System of Osteotomy Blade Plates and Cannulated Instrumentation Cannulated Pediatric Osteotomy System (CAPOS) Surgical Technique Table of Contents Introduction Cannulated Pediatric Osteotomy System
More informationLCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.
LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved
More information2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.
2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System. Technique Guide Instruments and Implants approved by the AO Foundation Table of Contents Introduction 2.4 mm LCP Radial
More informationLarge Fragment LCP Instrument and Implant Set
Part of the DePuy Synthes Locking Compression Plate (LCP ) System Large Fragment LCP Instrument and Implant Set Surgical Technique Table of Contents Introduction Large Fragment LCP Instrument and Implant
More informationTrochanter Stabilization Plate for DHS Implants
Extends DHS Plate Construct to Help Stabilize Greater Trochanter Trochanter Stabilization Plate for DHS Implants Surgical Technique Table of Contents Introduction Trochanter Stabilization Plate for DHS
More informationDistal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)
Distal Radius Plate Instrument and Implant Set Surgical Technique Discontinued December 2017 DSUS/TRM/0916/1063(1) The Distal Radius Plates Indications For fixation of fractures and osteotomies, including
More informationSmall Fragment Locking Compression Plate (LCP ) System
Stainless Steel and Titanium Small Fragment Locking Compression Plate (LCP ) System Surgical Technique Table of Contents Introduction Small Fragment Locking Compression Plate (LCP) System 2 AO Principles
More informationTechnique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.
Technique Guide LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Table of Contents Introduction Features and Benefits 2 AO ASIF Principles 4 Indications 5 Surgical
More informationVA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
Technique Guide VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Table of Contents Introduction VA-LCP Anterior
More informationLCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.
Technique Guide LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Table of Contents Introduction LCP Proximal
More information4.5 mm LCP Condylar Plate Aiming Instruments
Part of the LCP Periarticular Aiming Instrument System (Large) 4.5 mm LCP Condylar Plate Aiming Instruments Surgical Technique Table of Contents Introduction 4.5 mm LCP Condylar Plate Aiming Instruments
More informationLow Profile Neuro Plating System. Surgical Technique
Low Profile Neuro Plating System Surgical Technique TABLE OF CONTENTS INTRODUCTION Low Profile Neuro Plating System 2 SURGICAL TECHNIQUE Technique 5 PRODUCT INFORMATION Low Profile Neuro Plates 10 Low
More informationLCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.
LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Surgical Technique This publication is not intended for
More information2.4 mm Variable Angle Locking Intercarpal Fusion System
For Partial Wrist Arthrodesis With Variable Angle Locking Technology 2.4 mm Variable Angle Locking Intercarpal Fusion System Surgical Technique Table of Contents Introduction 2.4 mm Variable Angle Locking
More informationLCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.
LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system. Technique Guide This publication is not intended for distribution in the USA. Instruments and implants approved
More informationVariable Angle LCP Locking Technology
BUILDING ON SUCCESS Variable Angle LCP Locking Technology The Evolution of Plating Technology Round Screw Hole Dynamic Compression Plate Limited-Contact Dynamic Compression Less Invasive Stabilization
More informationTechnique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.
Technique Guide TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee. Table of Contents Introduction TomoFix Osteotomy System 2 AO Principles 4 Indications
More informationTechnique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.
Technique Guide 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System. Table of Contents AO ASIF Principles of Internal Fixation 4 Indications/Contraindications 5 Surgical Technique
More informationLCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.
LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. Surgical Technique This publication is not intended for distribution in the USA. Instruments
More informationTechnique Guide. LCP Posterior Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment LCP system.
Technique Guide LCP Posterior Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment LCP system. Table of Contents Introduction LCP Posterior Medial Proximal Tibial Plate 3.5 2 AO Principles
More information2.7 mm/3.5 mm Variable Angle LCP. Ankle Trauma System
Part of the DePuy Synthes Variable Angle Locking Compression Plate (VA LCP ) System 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Surgical Technique Table of Contents Introduction 2.7 mm/3.5 mm
More informationTechnique Guide. 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System.
Technique Guide 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System. Table of Contents Introduction 4.5 mm LCP Proximal Tibia Plates 2 AO Principles 4 Indications 5 Surgical
More informationDistal Radius Sterile Kit. Optimization And Efficiency You Can Rely On
Distal Radius Sterile Kit Optimization And Efficiency You Can Rely On Introducing The Distal Radius Sterile Kit Improved OR Workflow The Distal Radius Sterile Kit provides high-quality single-use implants
More information2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.
2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction 2.7
More information3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.
3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction
More informationTechnique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.
Technique Guide PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus. Table of Contents Introduction PHILOS and PHILOS Long 2 AO Principles 4 Indications 5 Surgical Technique
More informationmodular ClaVICle PlaTe system
modular ClaVICle PlaTe system 3.7 mm/3.3 mm VA LCP Anterior Clavicle Plates and 3.3 mm Superior Anterior Clavicle Plates surgical TeChnIque Table of Contents Introduction Modular Clavicle Plate System
More informationLCP Distal Tibia Plate
Surgical Technique LCP Locking Compression Plate Original Instruments and Implants of the Association for the Study of Internal Fixation AO/ASIF Table of contents Indications 3 Implants/Instruments 5 Surgical
More information3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM
3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM Part of the DePuy Synthes Variable Angle Periarticular Plating System SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION 3.5 mm VA-LCP Proximal Tibial Plate 2 AO
More informationLCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.
LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.
More information2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.
2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Surgical Technique This publication is not intended
More informationTechnique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.
Technique Guide 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4 mm Variable Angle LCP
More information2.4 mm Variable Angle LCP Dorsal Distal Radius Plate
For Fragment-Specific Fracture Fixation With Variable Angle (VA) Locking Technology 2.4 mm Variable Angle LCP Dorsal Distal Radius Plate Surgical Technique Table of Contents Introduction 2.4 mm VA LCP
More informationlow ProfIle neuro PlaTIng system
low ProfIle neuro PlaTIng system surgical TeChnIque Table of Contents Introduction Low Profile Neuro Cranial Plating System 2 Surgical Technique Technique 5 Product Information Low Profile Neuro Plates
More informationDOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs
DOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs Instruments and implants approved by the AO Foundation. This publication is not intended
More informationLCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
Technique Guide LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Table of Contents Introduction LCP Superior Clavicle
More informationLCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.
LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Surgical Technique This publication is not intended for
More informationTOMOFIX Medial Distal Femur Plate
For Closed-Wedge Varus Femoral Osteotomies TOMOFIX Medial Distal Femur Plate Surgical Techniquee TABLE OF CONTENTS INTRODUCTION TOMOFIX Medial Distal Femur Plate 2 AO Principles 4 Indications 5 SURGICAL
More informationTechnique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium.
Technique Guide Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium. Table of Contents Introduction Small Fragment Locking Compression Plate (LCP) System 2 AO Principles
More informationMINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM
MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM For stabilizing osteotomies of the canine and feline proximal tibia SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Mini Tibial Plateau Leveling
More informationLCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.
LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Surgical Technique LCP Small Fragment System This publication is not
More informationSurgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.
LCP Extra-articular Distal Humerus Plate. The anatomically shaped and angular stable fixation system for extraarticular fractures of the distal humerus. Surgical Technique This publication is not intended
More informationLCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Surgical Technique This publication is not intended for distribution
More informationTechnique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.
Technique Guide Locking Attachment Plate. For treatment of periprosthetic fractures. Table of Contents Introduction Locking Attachment Plate 2 Indications 4 Surgical Technique Patient Positioning 5 Preparation
More informationMini External Fixator
Stabilize the Phalanges and Metacarpals Mini External Fixator Surgical Technique Table of Contents Introduction Mini External Fixator 2 Indications 4 Surgical Technique Technique Overview 5 Product Information
More informationPHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.
PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the
More informationLCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.
LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.
More informationVariable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.
Technique Guide Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. Image intensifier control Warning This description
More information2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.
2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Technique Guide Instruments and implants approved by the AO Foundation Table
More informationTitanium Distal Femoral Nail System
For Retrograde Insertion Titanium Distal Femoral Nail System Surgical Technique Table of Contents Introduction Titanium Distal Femoral Nail System 2 AO Principles 4 Indications 5 Clinical Cases 6 Surgical
More information2.0 mm Mandible Locking Plate System
Advanced Plating System for Trauma, Microvascular Reconstruction, and Orthognathic Surgery 2.0 mm Mandible Locking Plate System Surgical Technique TABLE OF CONTENTS INTRODUCTION 2.0 mm Mandible Locking
More informationLCP Metaphyseal Plates. For extra-articular fractures.
LCP Metaphyseal Plates. For extra-articular fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier
More information2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.
2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the locking compression plate (LCP) system. Anatomically contoured Multiple screw options for fixedangle support Coaxial holes minimize screw head
More informationLCP Superior Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
LCP Superior Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Surgical Technique This publication is not intended for
More informationLCP Periarticular Proximal Humerus Plate 3.5. The anatomic fixation system with anterolateral shaft placement.
LCP Periarticular Proximal Humerus Plate 3.5. The anatomic fixation system with anterolateral shaft placement. Surgical Technique This publication is not intended for distribution in the USA. Instruments
More informationVA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Surgical Technique This publication is not intended for distribution
More informationLCP Percutaneous Aiming System 3.5 for PHILOS. For less invasive surgery at the proximal humerus.
LCP Percutaneous Aiming System 3.5 for PHILOS. For less invasive surgery at the proximal humerus. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants
More informationVA LOCKING CALCANEAL PLATES 2.7
VA LOCKING CALCANEAL PLATES 2.7 Instruments and Implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Image intensifier control Warning
More information2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.
Technique Guide 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4
More informationLCP Extra-articular Distal Humerus Plate.
Technique Guide LCP Extra-articular Distal Humerus Plate. The anatomically shaped and angular stable fixation system for extraarticular fractures of the distal humerus. Table of Contents Introduction
More informationFor Fast and Stable Fixation of the Sternum. Sternal ZIPFIX. System. Surgical Technique
For Fast and Stable Fixation of the Sternum Sternal ZIPFIX System Surgical Technique TABLE OF CONTENTS INTRODUCTION Sternal ZIPFIX System 2 AO Principles 7 Indications and Contraindications 8 SURGICAL
More informationCOMPACT ANKLE FRACTURE SYSTEM
COMPACT ANKLE FRACTURE SYSTEM Consolidated ankle fracture solution for surgery centers SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Compact Ankle Fracture System 2 AO Principles 8 Indications 9 Clinical
More information6.5 mm midfoot fusion bolt
6.5 mm midfoot fusion bolt For intramedullary fixation of the medial column of the foot SurgIcal technique Table of Contents Introduction 6.5 mm Midfoot Fusion Bolt 2 AO Principles 4 Indications 5 Surgical
More informationLCP Ulna Osteotomy System 2.7. Low profile angular stable fixation for ulna shortening osteotomies.
LCP Ulna Osteotomy System 2.7. Low profile angular stable fixation for ulna shortening osteotomies. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants
More information2.4 mm LCP Distal Radius System
A Comprehensive Plating System to Address a Variety of Fracture Patterns 2.4 mm LCP Distal Radius System Surgical Technique Table of Contents Introduction 2.4 mm LCP Distal Radius System 2 AO Principles
More informationPeriarticular Aiming Arm Instruments for LCP Proximal Tibial Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large).
Technique Guide Periarticular Aiming Arm Instruments for LCP Proximal Tibial Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large). Image intensifier control Warning This description
More informationLCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.
LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved
More informationLag Screw Device Intended for symphyseal fracture fixation of the mandible
Lag Screw Device Intended for symphyseal fracture fixation of the mandible SUrgicaL TecHNiqUe Lag Screw Device Intended for symphyseal fracture fixation of the mandible Simplifies the lag screw fixation
More information