Vanguard. Total Knee System
|
|
- Baldwin Bruce
- 6 years ago
- Views:
Transcription
1 Vanguard Total Knee System
2 Why remove healthy ligaments?
3 DISCOVER NATURE AT WORK Bicruciate preserving total knee arthroplasty Thanks to a group of dedicated surgeons and designers, Biomet proudly introduces the newest bicruciate retaining total knee system, the Vanguard XP Total Knee. The Vanguard XP Total Knee system is a cruciate retaining design allowing healthy anterior cruciate ligaments (ACL) and healthy posterior cruciate ligaments (PCL) to be preserved while incorporating geometry to accommodate and enable the natural function of the knee s ligaments. Download the Biomet Scanner app on your smartphone from the itunes App Store or Google Play and scan the Vanguard XP implant image on opposite page to enhance your experience.
4 ATTENTION TO DETAIL Vanguard XP brings out the beauty from within The Vanguard XP Total Knee s tibial tray is a U-shaped design, now giving TKA surgeons the option of preserving healthy anterior and posterior cruciate ligaments. The asymmetric Vanguard XP Knee femoral component supports physiologic motion. The medial and lateral bearings are designed independently, allowing ACL/PCL interaction to drive knee motion.
5 FORGED FROM STRENGTH The embodiment of Biomet s commitment to durability Built with forged cobalt chrome and reinforced with Biomet s locking mechanism,** the Vanguard XP Knee s U-shaped tibial tray is designed for strength. The Vanguard XP Knee utilizes E1 Antioxidant Infused Bearing Technology - a technology that has shown to prevent oxidative degradation of the polyethylene. 1 As part of the Vanguard Knee System, the Vanguard XP Knee s versatile design allows for intraoperative flexibility, giving the option to: - Utilize the U-shaped tray for an ACL/PCL preserving total knee. - Utilize a cruciate retaining tibial tray for a PCL retaining total knee. - Utilize anterior stabilized bearings when the PCL is absent.
6 DEDICATION The epitome of Biomet knee design s Launch of the Maxim Total Knee System: A knee using the compressive locking bar mechanism on which the Vanguard XP Knee s locking mechanism is based. Launch of Arcom Polyethylene: Argon packaged DCM proven to reduce oxidation, 3 leading to the creation of E1 Antioxidant Infused Technology bearings. Launch of the Ascent Total Knee System: Heavy influencer of the soft-tissue friendly, swept-back femoral profile of the Vanguard and Vanguard XP femoral design. Designed from a heritage of clinical performance and innovation s Launch of the Vanguard Total Knee System: The most comprehensive total knee system on the market. US introduction of the Oxford Partial Knee: Only truly mobile meniscal bearing partial knee in the US and a key influencer for the Vanguard XP Knee s bicruciate preserving technique s First Oxford Partial Knee implanted by Mr. John Goodfellow. Manufacture polyethylene completely in-house, providing expertise in polyethylene development s Launch of AGC Total Knee System: First TKA with full interchangeability between tibial and femoral components along with a DCM Monoblock and first Biomet tibial locking clip, serving as the influencer of Vanguard Knee interchangeability design, further development of polyethylene and evolution of Biomet s locking mechanism. Introduction of Porous Plasma Spray: Fixation coating technology that continues to be utilized today as a result of its clinical performance. 2 Launch of E1 Antioxidant Infused Bearing Technology: Next generation polyethylene bearings clinically proven to maximize strength, wear resistance, and oxidative stability. 1 Launch of Signature* Personalized Patient Care in the Vanguard Complete Knee System: Allowing for efficiency by utilizing CT/MRI preoperative planning and patient-specific surgical positioning guides s Launch of Signature* Personalized Patient Care in the Oxford Partial Knee: Biomet s continued focus on versatility based on patient specific needs. Launch of the Vanguard Select Patient-Specific Femur: Allows the option to match a patient s unique anatomy while maintaining key Vanguard System design features. Launch of the Vanguard XP Total Knee System: The industry s latest bicruciate preserving total knee.
7 This material is intended for health care professionals. For complete product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the package insert on Check for country product clearances and reference product specific instructions for use. All content herein is protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet Inc. or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Biomet. Biomet does not practice medicine. The treating surgeon is responsible for determining the appropriate treatment, technique(s), and product(s) for each individual patient. References Meding, et al: Minimum 10-year Follow-Up of a Straight-Stemmed, Plasma- Sprayed, Titanium Alloy, Uncemented Femoral Component. AAOS Poster #PE396, March Beading, L.: Polyethylene-Related Failure: A Challenge to TKA. Orthopedics Today, 16 21, * A collaborative partnership with Materialise N.V. ** Vanguard XP Knee Testing Data on File Legal Manufacturer Biomet Orthopedics P.O. Box E. Bell Drive Warsaw, Indiana USA Biomet Orthopedics Form No. BMET REV0714 Biomet UK, Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK
Instrumentation Options
Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon
More informationTibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.
Tibial Fixation with TunneLoc Device Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D. Table of Contents Surgical Technique... 4 Ordering Information... 11 Indications For Use... 12 Contraindications...
More informationBiomet Multi-Axial Correction (MAC) System Correction Atlas
Biomet Multi-Axial Correction (MAC) System Correction Atlas Demonstrated with the XS MAC on a Left Tibia (CORA Centric Approach) Introduction... Page 1 Indications/ Contraindictions... Page 1 MAC Module
More informationComprehensive Reverse Shoulder System
Comprehensive Reverse Shoulder System Comprehensive Reverse Shoulder System Simple. Versatile. The Comprehensive Reverse Shoulder System is the next generation reverse shoulder prosthesis, offering unmatched
More informationFemoral Fixation for ACL Reconstruction. Surgical Protocol by Mark Gittins, D.O.
Femoral Fixation for ACL Reconstruction Surgical Protocol by Mark Gittins, D.O. Features A unique weave in which a single strand of braided polyethylene is woven through itself twice in opposite directions.
More informationPeanut Growth Control Plating System
At Biomet, engineering excellence is our heritage and our passion. For over 25 years, through various divisions worldwide, we have applied the most advanced engineering and manufacturing technology to
More informationWith over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world.
Oxford Partial Knee A Definitive Implant With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world. Compared with total
More informationMCL Reconstruction Surgical Protocol by Tarek Fahl, M.D.
MCL Reconstruction Surgical Protocol by Tarek Fahl, M.D. Features A unique weave in which a single strand of braided polyethylene is woven through itself twice in opposite directions This construct allows
More informationG7 ACETABULAR SYSTEM. beautifully. efficient.
G7 ACETABULAR SYSTEM beautifully efficient. HERITAGE MEETS MODERN DESIGN SIMPLICITY, EFFICIENCY AND PERFORMANCE The G7 System is a multi-bearing acetabular platform delivering simplicity, efficiency and
More informationOxford. Partial Knee
Oxford Partial Knee Oxford Partial Knee A Definitive Implant The Oxford Partial Knee is the most widely used 38 and clinically proven 22 partial knee replacement (PKR) system in the world, offering industry
More informationTHE PERSONALIZED KNEE
THE PERSONALIZED KNEE REDEFINING PERSONALIZATION Total knee replacement has long ranked among the most successful procedures in modern medicine. While you can expect excellent implant survivorship with
More informationOSS Modular Arthrodesis System. Assembly Guide
OSS Modular Arthrodesis System Assembly Guide One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical
More informationBTB ACL Reconstruction with the ToggleLoc Fixation Device with ZipLoop Technology. Surgical Technique by James R. Andrews, M.D.
BTB ACL Reconstruction with the ToggleLoc Fixation Device with ZipLoop Technology Surgical Technique by James R. Andrews, M.D. Table of Contents Femoral Tunnel Preparation... 4 Prepare ToggleLoc Device...
More informationcomprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology
comprehensive shoulder system Design Rationale Knees Hips Extremities Cement and Accessories PMI TEchnology . INTRODUCTION The Comprehensive Shoulder System is an evolutionary design based on the successful
More informationArcos Modular Femoral Revision System
Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the
More informationKnee Replacement Implants
Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.
More informationPARTIALS?1 SHOULD BE AT LEAST 20% DID YOU KNOW OF KNEE REPLACEMENTS
PARTIAL KNEE DID YOU KNOW AT LEAST 20% OF KNEE REPLACEMENTS SHOULD BE PARTIALS?1 Research shows that surgeons utilizing Partial Knee Arthroplasty (PKA) for at least 20% of their annual knee arthroplasties
More informationSimplifying the Most Clinically Proven 1 Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation
Simplifying the Most Clinically Proven 1 Partial Knee in the World Oxford Partial Knee with Microplasty Instrumentation 1 Microplasty Instrumentation Innovative, Accurate, Reproducible Microplasty Instrumentation
More informationJuggerKnot Soft Anchor 1.0 mm Mini
JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Surgical Technique Surgical Protocols by Mark Rekant, M.D. A. Lee Osterman, M.D. One Surgeon. One Patient. Over 1
More informationReCap Product Rationale
ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales
More informationGender Solutions Patello-Femoral Joint System
Zimmer Biomet is the leading company in partial knee arthroplasty (PKA) 1 with over 40 years experience, offering a comprehensive range of anatomic and innovative solutions. Research shows that surgeons
More information3.0 mm Cannulated Screw System. Surgical Technique
3.0 mm Cannulated Screw System Surgical Technique 3 3.0 mm Cannulated Screw System Surgical Technique 3.0 mm Cannulated Screw System The 3.0 mm Cannulated Screw System is part of a series of cannulated
More informationA Systematic Review on Performance of the Vanguard Complete Knee System
A Systematic Review on Performance of the Vanguard Complete Knee System Author: Jing Xie, Ph.D. June 30, 2011 Abstract A systematic review was conducted to evaluate the clinical performance of the Vanguard
More informationRegenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology
Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationArcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System
Arcos Interlocking Distal Stem Surgical Technique Addendum to the Arcos Modular Femoral Revision System One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationFLH /11
FLH 225 04/11 This publication has been issued by: European Central Marketing Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel: +44 (0)1656 655221 Fax: +44 (0)1656 645454 www.biomet.com
More informationSignature Personalized Patient Care
Surgical Technique Acetabular Guide System Contents One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical
More informationDEVELOPED BY SURGEONS
DEVELOPED BY SURGEONS FOR SURGEONS Zimmer Biomet values our surgeon customers and the expertise and passion they bring to the field. The ROSA Knee System is a surgical assistant designed to adapt to each
More informationStageOne Knee Cement Spacer Molds. Surgical Technique
StageOne Knee Cement Spacer Molds Surgical Technique Figure 1: Internal depth gauge allows surgeon to customize thickness of tibial spacer. Figure 2: Articulating spacer supports patient range of motion.
More informationVanguard Complete Knee System
Complete Knee System Design Rationale Knees Hips Extremities Cement and Accessories PMI Technology 1 One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationSignature Personalized Patient Care*
Signature Personalized Patient Care* Surgical Technique Addendum Vanguard Complete Knee System One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care
More informationDermaSpan Acellular Dermal Matrix. Reinforcement of Ruptured Posterior Tibial Tendon Repair. Surgical Protocol by Charles Zelen, DPM, FACFAS
DermaSpan Acellular Dermal Matrix Reinforcement of Ruptured Posterior Tibial Tendon Repair Surgical Protocol by Charles Zelen, DPM, FACFAS One Surgeon. One Patient. Over 1 million times per year, Biomet
More informationJuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair
JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair Surgical Technique by Shabi Kahn, MD One Surgeon. One Patient. Over 1 million times per year,
More informationOver 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System
Over 20 Years of Proven Clinical Success Zimmer Natural-Knee II System CSTi Porous Coating Structurally similar to human bone CSTi porous coating combines the excellent biocompatibility of titanium with
More informationJuggerKnot Soft Anchor 1.0 mm Mini
JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Surgical Technique Surgical Protocols by Mark Rekant, M.D. A. Lee Osterman, M.D. One Surgeon. One Patient. Over 1
More informationTaperloc Complete Hip System. Surgical Technique
Taperloc Complete Hip System Surgical Technique One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical
More informationPersonalized Solutions. Portfolio Brochure
Personalized Solutions Portfolio Brochure PERSONALIZING THE FUTURE OF ORTHOPEDICS. Zimmer Biomet s Personalized Solutions Team is focused on creating a comprehensive, technology-based portfolio aimed
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationwith ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D.
with ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D. Features A unique weave in which a single strand of braided polyethylene is woven through itself twice
More informationSimplifying the Most Clinically Proven Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation
Simplifying the Most Clinically Proven Partial Knee in the World Oxford Partial Knee with Microplasty Instrumentation 1 Microplasty Instrumentation Innovative, Accurate, Reproducible Microplasty instrumentation
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationToggleLoc. Fixation Device. Surgical Technique. Femoral Fixation for ACL Reconstruction SPORTS MEDICINE. Surgical Protocol by Mark Gittins, D.O.
ToggleLoc Fixation Device Femoral Fixation for ACL Reconstruction Surgical Technique Surgical Protocol by Mark Gittins, D.O. SPORTS MEDICINE One Surgeon. One Patient. Over 1 million times per year, Biomet
More informationDVR Crosslock Distal Radius Plating System. Product Brochure
DVR Crosslock Distal Radius Plating System Product Brochure One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art
More informationCoAxial Spray Kit. Simplifying the Application of Platelet-Rich Plasma onto Graft Material. Surgical Technique
CoAxial Spray Kit Simplifying the Application of Platelet-Rich Plasma onto Graft Material Surgical Technique 1 CoAxial Spray Kit Surgical Technique CoAxial Spray Kit The Zimmer Biomet Biologics CoAxial
More informationGreater Component Accuracy...
Greater Component Accuracy... StageOne cement spacer molds are designed to provide the surgeon with choices never before offered in two-stage revision knee surgery for an infected total joint. StageOne
More informationMedial Portal ACL Reconstruction
Medial Portal ACL Reconstruction with Precision Flexible Reaming Instrumentation Surgical Technique by William Prickett, M.D. and Gregory J. Loren, M.D., FAAOS Table of Contents Introduction... 2 Portals...
More informationComprehensive Solutions
Comprehensive Solutions Supporting healthcare professionals Flexibility Today s knee implant patients present increasingly diverse scenarios. The versatility of the JOURNEY II Total allows surgeons to
More informationConsistency in U2 Knee System over Time
U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility
More informationONCE OA PAIN STARTS, IT S HARD TO STOP. nstride Autologous Protein Solution
ONCE OA PAIN STARTS, IT S HARD TO STOP. nstride Autologous Protein Solution Frequently Asked Questions About nstride Autologous Protein Solution (APS) What is nstride APS? nstride APS is an autologous
More informationAvenir Femoral Hip System
Avenir Femoral Hip System Avenir Hip System Intuitive and Reproducible During its decade of experience in the bone compaction stem market, the Avenir Hip System has helped surgeons experience flexible,
More informationStageOne. Shoulder Cement Spacer Molds. Surgical Technique
StageOne Shoulder Cement Spacer Molds Surgical Technique One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art
More informationACL Reconstruction Single Tibial Tunnel Double Bundle
ACL Reconstruction Single Tibial Tunnel Double Bundle with the ToggleLoc Fixation Device with ZipLoop Technology Surgical Technique by Eric McCarty, M.D. Table of Contents Portal Position and Sizing of
More informationToggleLoc Inline Device
ToggleLoc Inline Device with ZipLoop Technology and TunneLoc Tibial Fixation for ACL Reconstruction Surgical Technique Surgical Protocol by Jeffrey M. Conrad, M.D. SPORTS MEDICINE One Surgeon. One Patient.
More informationScan Bi-Polar 22/28. Operative Technique
Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual
More informationBiologically-Assisted ACL Reconstruction. Surgical Technique
Biologically-Assisted ACL Reconstruction Surgical Technique One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art
More informationVault Reconstruction System. Meet Your Match
Vault Reconstruction System Meet Your Match 2 Vault Reconstruction System Routine Isn t Always Right Your world is defined by complexity, intricacy and variation. From narrowed vaults and thinned glenoid
More informationI want that next-generation knee
I want that next-generation knee High flex Potentially longer-lasting More normal feeling Gender-optimized Less-invasive procedure Advanced design technology The last ten years have yielded an explosion
More informationPositioning Sleeve Surgical Technique
Positioning Sleeve Surgical Technique Surgical Technique The Comprehensive Fracture System offers a unique tool to evaluate and re-establish humeral height, which can be critical to restoring proper biomechanics
More informationRegenerex Primary Tibial Tray
Cruciate Retaining and Posterior Stabilized Surgical Technique Addendum to the Vanguard Complete Knee System Knees Hips Extremities Cement and Accessories PMI Technology Contents Microplasty Knee Instrumentation
More informationVanguard 360 Revision Knee System. Design Rationale
Vanguard 360 Revision Knee System Design Rationale One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical
More informationBone Preservation Stem
TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
More informationJOURNEY II XR Bi-Cruciate Retaining Knee System: Design rationale and early results. Type of evidence. Design rationale.
Bone&JointScience Our Innovation in Focus Vol 07 No 01 March 2017 JOURNEY II XR Bi-Cruciate Retaining Knee System: Design rationale and early results John Watson 1 ; Nathan Lenz, MS 2 1. Smith & Nephew,
More informationRotating Platform System. Product Rationale
References 1. Meftah M, Ranawat A, Ranawat C. Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilised Total Knee Arthroplasty. J Bone Joint Surg Am. 2012; 94:426-32 2. Dalury D, Gonzales R, Adams
More informationOSSIS is an ISO accredited company.
CUSTOM IMPLANTS Over the last 15 years Ossis orthopaedic surgeons and materials and design engineers have been at the leading-edge of innovation in patient-specific implants. Ossis combines the use of
More informationHIP ARTHROSCOPY BROCHURE
HIP ARTHROSCOPY BROCHURE Biomet Sports Medicine designed, developed, and launched the first all-suture anchor on the market, known as the JuggerKnot Soft Anchor. Once surgeons began utilizing this anchor
More informationPersonalized Solutions. MRI Protocol for PSI and Signature Guides
Personalized Solutions MRI Protocol for PSI and Signature Guides 2 Personalized Solutions MRI Protocol for PSI and Signature Guides Purpose and Summary This protocol is applicable for the Zimmer Biomet
More informationTotal Knee Replacement
Total Knee Replacement A total knee replacement, also known as total knee arthroplasty, involves removing damaged portions of the knee, and capping the bony surfaces with man-made prosthetic implants.
More informationJuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair
JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair Surgical Technique by Shabi Kahn, MD One Surgeon. One Patient. Over 1 million times per year, Biomet
More informationActive Articulation E1
Active Articulation E1 Dual Mobility Hip System Design Rationale Knees Hips Extremities Cement and Accessories PMI Trauma Technology Active Articulation E1 Dual Mobility Hip System Dual Mobility: Not a
More informationSidus Stem-Free Shoulder. Secure fixation through a bone-sparing design
Sidus Stem-Free Shoulder Secure fixation through a bone-sparing design An efficient, bone-sparing solution, should revision become necessary Humeral shaft is untouched, minimal bone is removed from the
More informationConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:
ConforMIS, Inc. 28 Crosby Drive Bedford, MA 01730 Phone: 781.345.9001 Fax: 781.345.0147 www.conformis.com 0086 Authorized Representative: Medical Device Safety Service, GMBH Schiffgraben 41, 30175 Hannover,
More informationSulzer Orthopedics Joint & Fracture Care
Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage
More informationSurgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6
Surgical Technique Figure 1 Figure 4 Figure 3 Figure 5 Drill through the femoral aimer with a graft passing pin until the pin penetrates the patient s skin. Using an acorn reamer, ream the desired length
More informationSurgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6
Surgical Technique Figure 1 Figure 4 Figure 3 Figure 5 Drill through the femoral aimer with a graft passing pin until the pin penetrates the patient s skin. Using an acorn reamer, ream the desired length
More informationNexGen Legacy LPS-Flex Knee. Brochure
NexGen Legacy LPS-Flex Knee Brochure What postoperative range of motion can your TKA patients expect? For patients with the ability and desire to perform For patients with the ability high-flexion activities,
More informationComposiTCP Anchor with BroadBand Tape
ComposiTCP Anchor with BroadBand Tape featuring Medial Row Knot Tying Surgical Technique 2 ComposiTCP Anchor with BroadBand Tape Surgical Technique Figure 1 Figure 2 Step 1 Place the ComposiTCP punch/tap
More informationStephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty
Stephen R Smith Northeast Nebraska Orthopaedics PC Ligament Preserving Techniques in Total Knee Arthroplasty 10-15% have Fair to poor Results? Why? The complication rate is 2.567% If It happens To You
More informationEvolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects
Evolution Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee Key Aspects MicroPort s EVOLUTION Medial-Pivot Knee System was designed to recreate the natural anatomy that is lost during a total
More informationThe bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series
The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology porous primary hip series BI-METRIC XR SERIES implant technology The Bi-Metric XR Hip Series
More informationOSSIS is an ISO accredited company.
CUSTOM IMPLANTS Over the last 15 years Ossis orthopaedic surgeons and materials and design engineers have been at the leading-edge of innovation in patient-specific implants. Ossis combines the use of
More informationDePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)
This publication is not intended for distribution in the USA. DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England
More informationDual Articular.
Dual Articular 2000 www.biomet.co.uk D e s i g n R a t i o n a l e The Dual Articular Knee has been in use since 1991 and offers a flexible reconstructive solution for total knee surgery; for both revision
More informationTOTAL KNEE ARTHROPLASTY (TKA)
TOTAL KNEE ARTHROPLASTY (TKA) 1 Anatomy, Biomechanics, and Design 2 Femur Medial and lateral condyles Convex, asymmetric Medial larger than lateral 3 Tibia Tibial plateau Medial tibial condyle: concave
More informationEXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM
EXACTECH KNEE Operative Technique ADDENDUM Metaphyseal Cones Surgeon focused. Patient driven. TM TABLE OF CONTENTS INTRODUCTION...1 DESCRIPTION...1 DETAILED OPERATIVE TECHNIQUE Initial Preparation and
More informationTiLENE. Plug Set Titanized Polymers. Surgical Technique
Titanized Polymers Surgical Technique The only Plug Implant with a Titanium Coating Excellent biocompatibility through a unique combination of a compound material with a covalent bonded titanium layer
More informationACL Reconstruction Medial Portal
ACL Reconstruction Medial Portal with ToggleLoc Fixation Device with ZipLoop Technology and ComposiTCP Interference Screw Surgical Technique by Jefferey Michaelson, M.D. Table of Contents Tunnel Preparation...
More informationOptimum implant geometry
Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationZimmer Biomet US Cement and Infection Product Portfolio
Zimmer Biomet US Cement and Infection Product Portfolio Bone Cement Biomet Bone Cement R 110035368 Biomet Bone Cement R 1X40 1 Refobacin Bone Cement R 110034355 Refobacin Bone Cement R 1X40 (With Gentamicin)
More informationINSTRUMENTS. Design Rationale
INSTRUMENTS Design Rationale High Performance instruments that support your approach, your patient demand and your choice of knee system. Contemporary total knee arthroplasty demands high performance instrumentation
More informationACETABULAR CUP SURGICAL TECHNIQUE
ACETABULAR CUP SURGICAL TECHNIQUE ACETABULAR CUP DEVICE INDICATIONS FOR USE The ICONACY I-Hip total hip replacement is indicated for the following conditions: 1. A severely painful and/or disabled hip
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationKnee Revision. Portfolio
Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and
More informationThe AperFix II System
The AperFix II System A Complete Anatomic Solution Transtibial Surgical Technique 2 AperFix II System Transtibial Surgical Technique Figure 1 A Complete Anatomic Solution The Cayenne Medical AperFix and
More informationFeatures. The hollow core can be filled with autograft or allograft bone.
Materials that resorb into the human body have been emerging over the past thirty years. Today, there are numerous implants available in the field of orthopedic surgery, the gold standard of ACL reconstruction
More informationHOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX
HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HIP IMPLANTS TOTAL HIPS Ultra High Demand (metal on metal) Femur, ingrowth Femoral head, metal Acetabular shell, ingrowth Acetabular liner,
More informationUnderstanding Hip Implant Options
Understanding Hip Implant Options Cup (Socket) Bearing (Liner) Head Stem (Femur) Modern Hip Implants (Ball) Metal Femoral Head on Marathon Cross-linked Polyethylene Liner Proven materials Polyethylene
More informationFlexible Fragment Fixation. Surgical Technique
Flexible Fragment Fixation Surgical Technique 2 F 3 Flexible Fragment Fixation The F 3 Fragment Plating System offers low profile, yet strong fixation in a locked plating construct that can be contoured
More informationPatient-specific bicompart mental knee resurfacing system
iduog2 Patient-specific bicompart mental knee resurfacing system Superior implant fit and performance require a patient-specific approach. The ConforMIS Partial Knee Resurfacing Systems use proprietary
More informationThe challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery
The challenge Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery THA 52% Post-op TKA 42% Preop 36% Preop 34% Post-op Total
More informationCommon Instruments for Biomet Hip Systems
E F F I C I E N T E F F E C T I V E E Common Instruments for Biomet Hip Systems X A C T I N S T R U M E N TAT I O N Exact Hip Instrumentation was developed by Biomet engineers to address the needs of today
More information