Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

Size: px
Start display at page:

Download "Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER"

Transcription

1 XPS 10/15 F SERIESTRANSDUCER Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 techpubs@milltronics.com For the library of SMPI instruction manuals, visit our Web site: Siemens Milltronics Process Instruments Inc. 2001

3 Table of Contents About Milltronics Transducers...5 Hazardous Area Applications...5 Specifications...7 XPS 10 F Series Transducers...7 XPS 15 F Series Transducers...8 Outline and Dimensions...9 XPS 10 F Series Transducers...9 XPS-15 F Series Transducers...10 Mounting...11 Recommendations...11 Solids Applications...11 Liquid Applications...12 Interconnection...15 Recommendations...15 Applications...17 Liquid Applications...17 Solids Applications...22 Installation Diagram for the XPS 10 F...26 PL-551 XPS 10/15 F Series Transducer Page 3

4 Page 4 XPS 10/15 F Series Transducer PL-551

5 About Milltronics Transducers The Echomax XPS F series of transducers operates in association with Milltronics ultrasonic level monitoring products. The transducer operates by converting electrical pulses that are provided by the transceiver into ultrasonic pulses. When transmitted, these ultrasonic pulses reflect from the material surface and echo back to the transducer. The echo is converted back to an electrical signal, and is interpreted by the Milltronics tranceiver using our proven Sonic Intelligence algorithms. hazardous seal (XPS 10 F series only) transducer transducer face About the The effective acoustical energy is emitted from the transducer face and radiated outward, decreasing in amplitude at a rate inversely proportional to the square of the distance. -3db boundary Maximum power is radiated axially (perpendicular) from the transducer face in a line referred to as the axis of transmission. Where power is reduced by half ( 3 db), a conical boundary defining the sound beam, centered about the axis of transmission, is established. The diametric measurement of the cone in degrees defines the beam angle. Impedance matching techniques are axis of transmission, perpendicular to transducer face used to optimize the transfer of power from the transducer into air and vice versa. The XPS F series transducers incorporate an integral temperature sensor that reports the air temperature at the transducer to the transceiver. The connection is transparent, in that both the ultrasonic and temperature components of the transducer use the same leads. Hazardous Area Applications The Echomax XPS F series of transducers can be used in hazardous areas. For the XPS 10 F series transducer, a hazardous seal must be used to suit hazardous area classification. This seal is not supplied by Milltronics. The XPS 15 F comes equipped with a stainless steel coupling suitable for use in hazardous locations. PL-551 XPS 10/15 F Series Transducer Page 5

6 About the Page 6 XPS 10/15 F Series Transducer PL-551

7 Specifications XPS 10 F Series Transducers Measurement Range: { m (1 33ft) Frequency: { 43kHz Beam Angle: { 12 Environmental { location: { indoor/outdoor { altitude: { 2000m maximum { ambient temperature: { -20 to 95 C (-4 to 203 F) { pollution degree: { 4 Specifications Construction { exposure: { Kynar 1 { colour: { slate gray { mounting: { 1 NPT conduit connection { options: { factory flange to suit ANSI standard { submergence shield, where flooding can occur { split flange for field mounting to suit ANSI { cable: { 2-wire shielded / twisted, 0.5 mm 2 (20 AWG) PVC jacket Supply Source { Transducer shall only be supplied by a Milltronics certified controller. Weight 2 { 0.8kg (1.8lb) Separation { 365m (1200ft) from transducer Approvals { FM Class 1 Div 1, Group A, B, C and D { FM Class 2 Div 1, Group E, F, and G { see nameplate or consult Milltronics for other current approvals 1 Kynar is registered trade mark of ELF Atochem. 2 approximate shipping weight of transducer with standard cable length PL-551 XPS 10/15 F Series Transducer Page 7

8 XPS 15 F Series Transducers Measurement Range: { m (1.5 50ft) Frequency: { 43kHz Beam Angle: { 6 Specifications Environmental { location: { indoor/outdoor { altitude: { 2000m maximum { ambient temperature: { -20 to 95 C (-4 to 203 F) { pollution degree: { 4 Construction { exposure: { Kynar 3 { colour: { slate gray { mounting: { 1 NPT conduit connection { options: { factory flange to suit ANSI standard { submergence shield, where flooding can occur { split flange for field mounting to suit ANSI { cable: { 2-wire shielded / twisted, 0.5 mm 2 (20 AWG) PVC jacket Supply Source { Transducer shall only be supplied by a Milltronics certified controller. Weight 4 { 2.0 kg (4.4lb) Separation { 365m (1200ft) from transducer Approvals { FM Class 1 Div 1, Group A, B, C and D { FM Class 2 Div 1, Group E, F, and G { see nameplate or consult Milltronics for other current approvals 3 Kynar is registered trade mark of ELF Atochem 4 approximate shipping weight of transducer with standard cable length Page 8 XPS 10/15 F Series Transducer PL-551

9 Outline and Dimensions XPS 10 F Series Transducers Standard Flange (optional) 122mm (4.8 ) 122mm (4.8 ) 86mm (3.4 ) Split Flange (optional) radiating face to suit ANSI standards Submergence Shield (optional) Outline & Dimensions 128mm (5.0 ) nominal 152mm (6.0 ) to suit ANSI standards 124mm (4.9 ) Refer to submergence shield instructions (Milltronics manual number PL-530) Note: For the XPS 10 F series transducer, a hazardous seal must be used to suit hazardous area classification. This seal is not supplied by Milltronics. For more information, refer to page 26. PL-551 XPS 10/15 F Series Transducer Page 9

10 XPS-15 F Series Transducers Standard Flange (optional) 1 NPT 304 stainless steel 185mm (7.3 ) 185mm (7.3 ) 120mm (4.7 ) radiating face to suit ANSI standards Split Flange (optional) Submergence Shield (optional) Outline & Dimensions 191mm (7.5 ) nominal 253mm (10.0 ) to suit ANSI standards 158mm (6.2 ) Refer to submergence shield instructions (Milltronics manual number PL-530) Note: The XPS 15 F comes equipped with a stainless steel coupling suitable for use in hazardous locations. Page 10 XPS 10/15 F Series Transducer PL-551

11 Mounting Recommendations Special handling precautions must be taken to protect the face of the transducer from any damage. Mount the transducer so that it is above the maximum material level by at least the blanking value (0.3m for XPS 10 F and 0.45m for XPS 15 F). Refer to the associated transceiver manual for instructions on setting the blanking value. On liquid applications, the transducer must be mounted so that the axis of transmission is perpendicular to the liquid surface. On solids applications, a Milltronics Easy Aimer should be used to facilitate aiming of the transducer. Do not over-tighten mounting. Hand tightening of the mounting hardware is sufficient. Secure installation by connecting a safety chain from the transducer to a structural member. Consider the optional temperature sensor when mounting the transducer. Solids Applications (XPS 10 F shown) Easy Aimer (typical model) Mounting safety chain transducer Note: For the XPS 10 F series transducer, a hazardous seal must be used to suit hazardous area classification. This seal is not supplied by Milltronics. For more information, refer to page 26. PL-551 XPS 10/15 F Series Transducer Page 11

12 Liquid Applications Notes: In, the examples that follow, an XPS 10 F Series transducer is shown using a hazardous seal. This seal is not supplied by Milltronics. An XPS 15 F transducer can also be used in these applications, but, because it comes equipped with a stainless steel coupling, no hazardous seal is required. Flexible Conduit (XPS 10 F shown) Bracket (XPS 10 F shown) flexible conduit steel channel safety chain hazardous seal (XPS 10 F only) transducer Flexible conduit transducer should not be subjected to wind, vibration or jarring. Submersible (XPS 10 F shown) Mounting rigid metal conduit safety chain hazardous seal (XPS 10 F only) submergence shield Submersible transducer, used in applications where flooding is possible. Page 12 XPS 10/15 F Series Transducer PL-551

13 Blind Flange (XPS 10 F shown) nipple welded to bind flange hazardous seal (XPS 10 F only) Flange, gasket, hazardous seal and hardware supplied by customer. Refer to page 19 Flanged (XPS 10 F shown) hazardous seal (XPS 10 F only) factory flanged transducer bolt Mounting gasket customer flanged, flat face only nut Flange, gasket, and hardware supplied by customer. Refer to page 19 Note: Tighten the flange bolts evenly in order to ensure a good seal between the mating flanges. Caution: Over-tightening can cause performance degradation. PL-551 XPS 10/15 F Series Transducer Page 13

14 Mounting Page 14 XPS 10/15 F Series Transducer PL-551

15 Interconnection Note: Installation should only be performed by qualified personnel and in accordance with local governing regulations. Recommendations When using an XPS 15 F transducer, configure the electronic transceiver for an XCT-12. These two transducers use the same settings. Do not route cable openly. For optimum isolation against electrical noise, run cable separately in a grounded metal conduit. Seal all thread connections to prevent ingress of moisture. Do not run cable near high voltage or current runs, contactors and SCR control drives. Note: In the interconnection examples that follow: an XPS 10 F Series transducer is shown. An XPS 15 F transducer can also be used, but no hazardous seal is required. assume that the transducer is located in a Hazardous location (Class I, Div. 1, Group A,B,C,D or Class II, Div. 1, Group E,F,G.) and the transceiver in a Non-Hazardous (Safe) Location. Direct Connection (XPS 10 F shown) Hazardous Location (Class I, Div. 1, Group A,B,C,D or Class II, Div. 1, Group E,F,G) Non-Hazardous Location (Safe) blk wht metal conduit drain / shield Note: When connecting to an EnviroRanger ERS 500, the white, black, and shield wires are all connected separately. Do not tie the white and shield wires together. Interconnection PL-551 XPS 10/15 F Series Transducer Page 15

16 2-Wire Extension (XPS 10 F shown) Hazardous Location (Class I, Div. 1, Group A,B,C,D or Class II, Div. 1, Group E,F,G) Non-Hazardous Location (Safe) junction box metal conduit drain / shield blk wht extend cable using 18 AWG shielded / twisted pair Note: When connecting to an EnviroRanger ERS 500, the white, black, and shield wires are all connected separately. Do not tie the white and shield wires together. Coaxial Cable (XPS 10 F shown) Hazardous Location (Class I, Div. 1, Group A,B,C,D or Class II, Div. 1, Group E,F,G) Non-Hazardous Location (Safe) metal conduit extend cable using RG 62 A/U coax for optimum noise immunity Interconnection Note: When connecting to an EnviroRanger ERS 500, do NOT use coaxial cable. Page 16 XPS 10/15 F Series Transducer PL-551

17 Applications Notes: The transducer is to be used only in the manner outlined in this instruction manual. Normally, the transducer requires no cleaning or maintenance. However, if performance changes are observed, immediately shut down the level measurement system and perform a thorough inspection, especially on the transducer. An XPS 10 F Series transducer is shown in these examples. An XPS 15 F transducer can also be used, but no hazardous seal is required. Liquid Applications Stilling Well / OCM Applications blind flange air vent TS-3 * transducer standpipe bracing standpipe inlet primary element stilling well stilling well inlet Refer to page 19. * the use of a TS-3 temperature sensor provides better temperature tracking in applications where the temperature can change quickly. PL-551 XPS 10/15 F Series Transducer Page 17

18 Submergence Applications In applications where flooding is possible, the transducer can be fitted with a submergence shield*. The shield acts as a bell to create an air pocket in front of the transducer face. The associated transceiver* interprets this as a flooding condition, and reacts accordingly. Note: Refer to transceiver manual for programming requirements. hazardous seal (XPS 10 F only) transducer submergence shield* (Refer to Milltronics instruction manual PL-530 for assembly details) air pocket * on applicable models Page 18 XPS 10/15 F Series Transducer PL-551

19 Standpipes In many applications, access must be made via a standpipe. In such cases, Milltronics can provide factory bonded flanged transducers or a split flange kit that will readily mate to the flanged standpipe. Another option is to hang the transducer from a blind flange. The standpipe length should be as short and the diameter as large as possible. As a rule of thumb, the -3 db cone of the sound beam should not intersect the standpipe wall in applications opening into a vessel or larger area. Otherwise, additional blanking will be required to compensate for the interference zone created by the opening. Applications Note: When using a stilling well, make sure there is no build-up, welds, couplings, or other debris on the inside of the well wall. This can affect reliability of measurement. flanged transducer no intersection no vessel vessel no additional blanking required no additional blanking required nipple welded into blind flange nipple welded into blind flange transducer can read level inside or below standpipe transducer transducer sound beam intersects standpipe end cut on a 45 angle typically vessel reflection at interference zone created by opening no additional blanking required near blanking extension of 150 mm (6 ) PL-551 XPS 10/15 F Series Transducer Page 19

20 Volume Applications Maintain full level for full calibration. Above this level erroneous readings will result as level has entered blanking zone. (shaded area) Alternate Preferred Bad tank manufacturer s full level beam angle span: corresponds to tank manufacturer s empty level. rise Empty level for alternate locations. Below this level, echo would reflect away from the transducer. may require target to obtain empty reading discharge tank manufacturer s empty level 1. Beam should not detect bin bottom. If this occurs, use range extension parameters (on transceivers where available) to omit false echoes. A 6 beam angle (XPS 15 F) represents a rise:run of about 20:1 (10:1 for the 12 beam angle of the XPS 10 F). In most tanks, the transducer should be centered as much as possible (without interference from inlet) for optimum reading range. 2. Sound beam must be perpendicular to liquid surface. If standpipe is used, refer to page Echo has missed improperly levelled transducer. 4. When performing an empty or full calibration, the tank must contain its normal vapour and be at its normal temperature. 5. When used in hazardous areas, the XPS 10 F series transducer (shown) must use a hazardous seal. This seal is not supplied by Milltronics. The XPS 15 F Series transducer comes equipped with a stainless steel coupling suitable for use in hazardous locations. Page 20 XPS 10/15 F Series Transducer PL-551

21 Water / Wastewater Differential Level Applications Pump Control Sewage Lift PL-551 XPS 10/15 F Series Transducer Page 21

22 Solids Applications Applications Typical 1. Transducer angled to avoid seams in bin wall and aimed at discharge in order to read bin when empty. 2. Avoid intersecting bin wall seams, structural members and wall irregularities. 1 bin wall seams 2 filling profile emptying profile 3. Transducer too close to material inlet. Falling material will intersect sound beam and cause erroneous readings or loss of echo. Easy Aimer 3 Page 22 XPS 10/15 F Series Transducer PL-551

23 4. On fluid like solids, aim transducer perpendicular to material surface. Applications minimal angle of repose 4 discharge 5. On dual discharge bins, aim each transducer at the discharge point. transducer 5 PL-551 XPS 10/15 F Series Transducer Page 23

24 Applications Special Storage Bin with Agitator 1. Transducer should be kept away from infeed. 2. Where agitators are in use, use the Agitator Discrimination parameter on transceivers where available. 3. Transducer should be aimed away from wall projections. 4. When used in hazardous areas, the XPS 10 F series transducer (shown) must use a hazardous seal. This seal is not supplied by Milltronics. The XPS 15 F Series transducer comes equipped with a stainless steel coupling suitable for use in hazardous locations. infeed agitator Page 24 XPS 10/15 F Series Transducer PL-551

25 Dryer - Wood Chips 1. Transducer should be mounted perpendicular to slope of wood chips. 2. When used in hazardous areas, the XPS 10 F series transducer (shown) must use a hazardous seal. This seal is not supplied by Milltronics. The XPS 15 F Series transducer comes equipped with a stainless steel coupling suitable for use in hazardous locations. Applications drag conveyor infeed typical low level typical high level PL-551 XPS 10/15 F Series Transducer Page 25

26 Installation Diagram for the XPS 10 F Page 26 XPS 10/15 F Series Transducer PL-551

27

28 *7ml19981DU01*

Ultrasonic Transducers

Ultrasonic Transducers Ultrasonic Transducers XPS10/15F Operating Instructions 08/2013 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

XRS-5/XRS-5CTRANSDUCER

XRS-5/XRS-5CTRANSDUCER XRS-5/XRS-5CTRANSDUCER Instruction Manual PL-590 January 2001 33455900 Rev. 2.0 RS-5 TRANSDUCER Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and

More information

XPS 10/15 F Series Transducer Instruction Manual PL-551 July 1999

XPS 10/15 F Series Transducer Instruction Manual PL-551 July 1999 XPS 10/15 F Series Transducer Instruction Manual PL-551 July 1999 33455510 Rev 2.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation,

More information

XRS-5 Transducer Instruction Manual PL-590 September 1999

XRS-5 Transducer Instruction Manual PL-590 September 1999 XRS-5 Transducer Instruction Manual PL-590 September 1999 33455900 Rev 1.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation, with

More information

(all beam angles defined as, -3dB or half power inclusive)

(all beam angles defined as, -3dB or half power inclusive) Transducers Transducers: Standard Range Encapsulated ATEX ( EEx m) for zones 1 and 2 as standard On NPT threaded versions, FM Class I, Div 1, Group A, B, C and D. Class II, Div 1, Group E, F and G. Class

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 85S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Installation manual ENGLISH www.simrad-yachting.com www.lowrance.com 1 Preface Warning: It is your sole responsibility to install

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 230S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 300S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

Upper sensor wire. Lower Sensor wire. U shape slider

Upper sensor wire. Lower Sensor wire. U shape slider 1. It is important to read this entire manual before assembling and using the equipment. Safe and effective use can only be achieved if the equipment is assembled, maintained and used properly. It is your

More information

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings R Description Although Proximitor and interface are rugged by design, these units and their electrical connections

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Installation Guide for ultrasonic transducers

Installation Guide for ultrasonic transducers Installation Guide for ultrasonic transducers 1 1. Welcome at systec Thank you very much for using deltawave. This document provides you with all necessary information to install the transducers accurately

More information

The Do s and Don ts of Pressure Transducers

The Do s and Don ts of Pressure Transducers The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed

More information

MAGNETIC EXERCISE BIKE CF 1560

MAGNETIC EXERCISE BIKE CF 1560 MAGNETIC EXERCISE BIKE CF 560 Important Safety Information Please keep this manual in a safe place for reference.. It is important to read this entire manual before assembling and using the equipment.

More information

TWISTING STAIR STEPPER WITH BANDS

TWISTING STAIR STEPPER WITH BANDS TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN

More information

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration

More information

w. D. Jolly, F. A. Bruton, and C. Fedor

w. D. Jolly, F. A. Bruton, and C. Fedor ULTRASONIC TRANSDUCER CHARACTERIZATION STATION w. D. Jolly, F. A. Bruton, and C. Fedor Southwest Research Institute 6220 Culebra Road San Antonio, Texas 78284 INTRODUCTION The portable ultrasonic transducer

More information

S51 Series. Thread Together, Maximum Flow with Minimum Spillage

S51 Series. Thread Together, Maximum Flow with Minimum Spillage S51 Series S A F E W A Y H Y D R A U L I C S Document No. 7951 rev. 003 Thread Together, Maximum Flow with Minimum Spillage Minimum Spill, High Flow, Heavy-Duty Quick Coupling SafeWay s S51 Series is a

More information

Chapter 5: Checking and Maintaining Ultrasound Equipment

Chapter 5: Checking and Maintaining Ultrasound Equipment Chapter 5: Checking and Maintaining Ultrasound Equipment Care and Cleaning (BB1564-AJ) Chapter 5: Checking and Maintaining Ultrasound Equipment 45 Ultrasound equipment requires regular checks and maintenance.

More information

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Document No. 129-405 SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Product Description The SED2 VFD NEMA Type 3R/3RHE, Bypasses are companion packages for the family of SED2

More information

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office

More information

Flume Installation Instructions

Flume Installation Instructions Flume Installation Instructions To ensure a successful installation, it is important to keep the following points in mind: 1) There should be no bend, dips, elbows, or flow junction immediately upstream

More information

INSTRUCTION MANUAL (MAN-70254)

INSTRUCTION MANUAL (MAN-70254) INSTRUCTION MANUAL (MAN-70254) CLEVELAND-KIDDER ULTRA SERIES UNDER PILLOW BLOCK TRANSDUCER MODELS: UPB1 & UPB2 REVISION AA Industrial Products Division 7550 Hub Parkway Cleveland, Ohio 44125 Phone: 216.524.8800

More information

Detection. at first sight. One of the newest trends

Detection. at first sight. One of the newest trends NDT Specialist Sami Hemminki, Inspecta, Finland, describes the benefits of guided wave ultrasonic testing. Detection at first sight One of the newest trends in pipeline testing is the use of guided wave

More information

Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules

Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules GEP-6063 Rev. T 102335 Ref. I.D.: 12978 WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND

More information

SMV-1 Assembly Manual

SMV-1 Assembly Manual SMV-1 075-0042_A Table of Contents Model SMV-1 Specifications........2 Safety Warnings........... 3 Safety Caution and Warning Labels........4 Before You Start...... 5 Hardware... 6 Box Contents........

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.

More information

TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL

TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact:

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency

More information

HPS Centurion R Iron Core Reactors

HPS Centurion R Iron Core Reactors Installation, Operation, and Maintenance Guide HPS Centurion R Iron Core Reactors This manual covers the recommendations for the installation, operation and maintenance of Centurion R reactors. It is emphasized

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ER75 Electro-Acoustic Ear Simulator. Operating Manual ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United

More information

Fittings & Accessories

Fittings & Accessories Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical

More information

WEIGHT SYSTEM EXERCISER User s Manual

WEIGHT SYSTEM EXERCISER User s Manual Model No. 831.14934.0 Serial No. Write the serial number in the space above for reference. WEIGHT SYSTEM EXERCISER User s Manual Serial Number Decal Assembly Operation Maintenance Part List and Drawing

More information

MARCY Magnetic-Resistance Upright Bike

MARCY Magnetic-Resistance Upright Bike NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Hardware Pack Assembly Instruction Parts List Warranty MARCY Magnetic-Resistance Upright Bike ME-708

More information

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT MXSelect. MX_Select.

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT   MXSelect. MX_Select. MX SELECT OWNER S MANUAL Revolutionising Strength Training REGISTER YOUR PRODUCT AT WWW.MXSELECT.COM MXSelect MX_Select MX-Select MX SELECT WELCOME TO THE MX SELECT FAMILY Congratulations on your purchase

More information

Most of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings.

Most of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings. InLine Installation Most of the Conductivity/Resistivity electrodes used with the 850 can be installed into standard /4 in. (NPT or ISO 7R /4) fittings. The 8505X models are designed for integral systems,

More information

Pipeline Technology Conference 2007

Pipeline Technology Conference 2007 The Complete Solution: Combined Crack and Metal Loss Detection Tool using Phased Array Technology By A. Hugger, J. Franz, H. Charbon, R. Bauernschmitt, M. Tschuch, K.-H. Käshammer, I. Lachtchouk, J. Ehrhardt.

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Introduction....2 300 V PVC Insulated, PVC Jacketed PLTC/ITC Rated Applications and Description....3 Overall Shielded Pairs....4 Overall Shielded Triads...5 Individual and Overall

More information

AquaJogg Hydro Treadmill

AquaJogg Hydro Treadmill AquaJogg Hydro Treadmill PART #: F-WXAQJG 330 LB. [150 kg] MAXIMUM WEIGHT CAPACITY MANDATORY LEAVE THIS MANUAL WITH TREADMILL OWNER To assemble your equipment read entire manual and follow all instructions.

More information

Gewässer Umwelt Schutz

Gewässer Umwelt Schutz Gewässer Umwelt Schutz GmbH CUW Oil protector Assembly instructions 2 Foreword Always study this assembly instruction manual before Installation and initial operation. This assembly instruction manual

More information

BODYSHAPER P20 OWNER S MANUAL

BODYSHAPER P20 OWNER S MANUAL BODYSHAPER P20 OWNER S MANUAL Product may vary slightly from the item pictured due to model upgrades Read all instructions carefully before using this product. Retain this owner s manual for future reference.

More information

Linear Array Transducer

Linear Array Transducer User Guide Type 8809 Linear Array Transducer English BB 0911-H August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

Simrad SP90/SX90/SU90

Simrad SP90/SX90/SU90 Simrad SP90/SX90/SU90 Transducer replacement procedure This document explains how to replace the transducer on a Simrad SP90, SX90 and SU90 Series hull unit. Note This procedure is not intended for end

More information

Important Safety Information

Important Safety Information Important Safety Information We thank you for choosing our product. To ensure your safety and health, please use this equipment correctly. Please read the information below carefully before using this

More information

Other Major Component Inspection II

Other Major Component Inspection II Other Major Component Inspection II Ultrasonic Inspection Technique for BWR Shroud Support Plate Access Hole Covers S.W. Glass III, B. Thigpen, Areva, France BACKGROUND Access hole covers (AHC) are found

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

RUBBER WATERBLAST HOSES

RUBBER WATERBLAST HOSES up to 15, PSI (1 Bar) RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability and safe performance. Designed specifically for waterblast applications Lightweight

More information

CANADA SENSORS TECHNOLOGY INC.

CANADA SENSORS TECHNOLOGY INC. CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters PRESSURE TRANSMITTER PROCESS 1 HART Enabled Intrinsically Safe Model Canada Sensors intelligent transmitters

More information

API. Defined Procedure. for. Ultrasonic Thickness Measurement API-UT-21

API. Defined Procedure. for. Ultrasonic Thickness Measurement API-UT-21 API Defined Procedure for Ultrasonic Thickness Measurement API-UT-21 This Procedure Defines the Recommended Ultrasonic Methods and Techniques for Thickness Measurements Page 1 1.0 PURPOSE 1.1 This procedure

More information

TECH 2 Dew Point Retrofit Kit

TECH 2 Dew Point Retrofit Kit TECH 2 Dew Point Retrofit Kit THORESON McCOSH TECH II Instruction Manual 412765A THORESON-McCOSH INC 1885 Thunderbird St. Troy MI. 48084 Phone 1-248-362-0960 Fax 1-248-362-5270 sales@thoresonmccosh.com

More information

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.  new products, prizes, fitness tips, and much more! Model No. WEBE44.0 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal QUESTIONS? As a manufacturer, we are committed to providing complete customer

More information

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2 Page: 1 of 6 TABLE OF CONTENTS SECTION PAGE NO. 1.0 Introduction 2 2.0 Reference Documents 2 3.0 Summary of Practice 2 4.0 Significance & Use 3 5.0 Apparatus 3 6.0 Calibration & Adjustment of Apparatus

More information

Angular Measurements with BIOPAC Goniometers & Torsiometers

Angular Measurements with BIOPAC Goniometers & Torsiometers APPLICATION NOTES 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com support@.biopac.com Application Note 140 Angular Measurements with BIOPAC Goniometers & Torsiometers

More information

DSI Series Installation

DSI Series Installation DSI Series Installation This document covers the installation of the DSI series transducer and display unit installation. Parts List Display unit Display unit bracket slotted-head (Phillips) mounting screws

More information

Mixing Degas Vessel (MDV) Mixing Degas Vessel (MDV) EC-1, EC-2, and EC-4 Flip Booklet for Total Eclipse Applications

Mixing Degas Vessel (MDV) Mixing Degas Vessel (MDV) EC-1, EC-2, and EC-4 Flip Booklet for Total Eclipse Applications Installation Manual for MDV Mixing Degas Vessel (MDV) EC-1, EC-2, and EC-4 Flip Booklet for Total Eclipse Applications EPA Estab. No. 071472-CA-001 Phone Fax San Luis Obispo, California, 93401 805.541.1601

More information

TWIST STEPPER NO. 045

TWIST STEPPER NO. 045 TWIST STEPPER NO. 045 IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact: support@sunnyhealthfitness.com

More information

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

OWNER S MANUAL and INSTALLATION INSTRUCTIONS NP-B7520 GLUTE / HAM OWNER S MANUAL and INSTALLATION INSTRUCTIONS Glute / Ham Owner s Manual Copyright 2016. Core Health and Fitness, LLC. All rights reserved, including those to reproduce this book or

More information

The Bowflex Conquest Home Gym Assembly Instructions

The Bowflex Conquest Home Gym Assembly Instructions The Bowflex Conquest Home Gym Assembly Instructions P/N 001-6841 Rev C (04/2007) Table of Contents Before You Start... 2 Tools You Will Need / Hardware Chart... 3 Parts List... 4 Weight and Multi-carton

More information

SureFlow. Oxygen Flow Station PROVIDER TECHNICAL MANUAL

SureFlow. Oxygen Flow Station PROVIDER TECHNICAL MANUAL SureFlow Oxygen Flow Station PROVIDER TECHNICAL MANUAL Table of Contents Definition of Product Symbols... 3 General Information... 3 Warning and Caution Statements...3 Introduction to the SureFlow Oxygen

More information

TORNADO AIR BIKE SF-B2706 USER MANUAL

TORNADO AIR BIKE SF-B2706 USER MANUAL TORNADO AIR BIKE SF-B2706 USER MANUAL IMPORTANT! Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact: support@sunnyhealthfitness.com

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Medescan Nebuliser Med - S600A Instructions Manual

Medescan Nebuliser Med - S600A Instructions Manual Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory

More information

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE.  Model No. WEBE Serial No. www.weiderfitness.com Model No. WEBE15911.0 Serial No. Write the serial number in the space above for reference. USER S MANUAL Serial Number Decal ACTIVATE YOUR WARRANTY To register your product and activate

More information

RaySafe i3 INSTALLATION & SERVICE MANUAL

RaySafe i3 INSTALLATION & SERVICE MANUAL RaySafe i3 INSTALLATION & SERVICE MANUAL 2017.06 Unfors RaySafe 5001104-1.1 All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

Developments in Ultrasonic Inspection II

Developments in Ultrasonic Inspection II Developments in Ultrasonic Inspection II An Ultrasonic Technique for the Testing of Plates Embedded in Concrete with Synthesis of Signals from a Multi-element Probe H. Ishida, Y. Kurozumi, Institute of

More information

AquaJogg Hydro Treadmill

AquaJogg Hydro Treadmill AquaJogg Hydro Treadmill PART #: F-WXAQJG 330 LB. [150 kg] MAXIMUM WEIGHT CAPACITY MANDATORY LEAVE THIS MANUAL WITH TREADMILL OWNER To assemble your equipment read entire manual and follow all instructions.

More information

N4i Installation Manual. (picture of N4i screen)

N4i Installation Manual. (picture of N4i screen) N4i Installation Manual (picture of N4i screen) 1 Table of Contents N4i Computer Parts List... 4 Netpulse Stabilizer Bar Parts List... 6 Hardware List... 7 Tools Needed for Installation... 7 N4i Assembly

More information

COMPETITOR COMPETITOR WEIGHT BENCH. Model CB Retain This Manual for Reference OWNER'S MANUAL

COMPETITOR COMPETITOR WEIGHT BENCH. Model CB Retain This Manual for Reference OWNER'S MANUAL NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Important Assembly Information COMPETITOR COMPETITOR WEIGHT BENCH CB-20111 Care and Maintenance Parts

More information

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

10 Years Experience in Industrial Phased Array Testing of Rolled Bars 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa 10 Years Experience in Industrial Phased Array Testing of Rolled Bars Josef MAIER 1 and Gerhard Ferstl 1, 1 Böhler

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8823 Convex Array Transducer English BB1740-C June 2012 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkmed.com Email:

More information

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques ECNDT 2006 - We.1.6.4 Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques Kaj K. BORUM, Risø National Laboratory, Materials Research Department, Roskilde,

More information

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

OWNER S MANUAL and INSTALLATION INSTRUCTIONS NP-L5003 Ab Crunch OWNER S MANUAL and INSTALLATION INSTRUCTIONS Leverage Ab Crunch Owner s Manual Copyright 2017. Core Health and Fitness, LLC. All rights reserved, including those to reproduce this book

More information

Compressor Accessories

Compressor Accessories Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500

More information

High Frequency Linear Array Transducer

High Frequency Linear Array Transducer User Guide Type 8870 High Frequency Linear Array Transducer English BB1980-C May 2016 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkultrasound.com

More information

Mass Fusion Splicing of Optical Fiber Ribbon Cables

Mass Fusion Splicing of Optical Fiber Ribbon Cables Application Notes Mass Fusion Splicing of Optical Fiber Ribbon Cables Author Prasanna Pardeshi and Sudipta Bhaumik Issued January 2014 Abstract To build a fiber optic network, one may eventually join two

More information

Important Safety Information

Important Safety Information Folding X Bike Important Safety Information PLEASE KEEP THIS MANUAL IN A SAFE PLACE FOR REFERENCE. It is important to read this entire manual before assembling and using the Confidence Folding X Bike.

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8802 Convex Array Transducer English BB0334-I August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

MEET THE DRIVING FORCE IN NEBULIZER THERAPY... Matched Nebulizer Compressor System

MEET THE DRIVING FORCE IN NEBULIZER THERAPY... Matched Nebulizer Compressor System MEET THE DRIVING FORCE IN NEBULIZER THERAPY... Matched Nebulizer Compressor System Matched Nebulizer Compressor System 4 1 Air is passed through an inlet filter. 2 Clean air is then driven through the

More information

D SERIES -011 USE MANUAL ROTARY TORSO

D SERIES -011 USE MANUAL ROTARY TORSO D SERIES -011 USE MANUAL ROTARY TORSO CONTENT IMPORTANT DECLARATION..1 WARNING..2 USE INSTRUCTION..3 REGULAR MAINTENANCE...4 CABLE ROUTING DIAGRAM..5 EXPLODED PICTURE...6 ASSMBLE STEP..7 IMPORTANT DECLARATION:

More information

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination

More information

MAGNETIC ELLIPTICAL TRAINER SF-E3608 USER MANUAL

MAGNETIC ELLIPTICAL TRAINER SF-E3608 USER MANUAL MAGNETIC ELLIPTICAL TRAINER SF-E3608 USER MANUAL WARNING! Your elliptical trainer is not designed for reverse pedaling. Failure to comply with this warning may result in permanent damage to your new equipment.

More information

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel: OWNER S MANUAL BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio 43035 Tel: 800.990.5556 1 www.bodycraft.com SAFETY INSTRUCTION WARNING: To reduce the risk of serious injury, read the following safety

More information

747 Series Stopper Plugs Cable Gland Accessories Flameproof.

747 Series Stopper Plugs Cable Gland Accessories Flameproof. 747 Series Stopper Plugs Flameproof. Class I, Groups, A, B, C, D Type 4X; Ex d II Component Equipment Stopper plug is designed for use from the outside of the Idea for use on flameproof electrical equipment

More information

D SERIES -018 USE MANUAL INNER THIGH ADDUCTOR

D SERIES -018 USE MANUAL INNER THIGH ADDUCTOR D SERIES -018 USE MANUAL INNER THIGH ADDUCTOR CONTENT IMPORTANT DECLARATION..1 WARNING..2 USE INSTRUCTION..3 REGULAR MAINTENANCE...4 CABLE ROUTING DIAGRAM..5 EXPLODED PICTURE...6 ASSMBLE STEP..7 IMPORTANT

More information

SelectTech 4.1 Bench Assembly / Owner s Manual

SelectTech 4.1 Bench Assembly / Owner s Manual SelectTech 4.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Table of Contents Important Safety Instructions...3 Safety Warning Labels and Serial Number...4

More information

INSTRUMENTATION. 300 Volt and 600 Volt Cables LEAD FREE O V E R Y E A R S O F E X P E R I E N C E. w w w. n e x a n s e n e r g y.

INSTRUMENTATION. 300 Volt and 600 Volt Cables LEAD FREE O V E R Y E A R S O F E X P E R I E N C E. w w w. n e x a n s e n e r g y. INSTRUMENTATION 300 Volt and 600 Volt Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Instrumentation Cables Introduction....2 300 V

More information

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT Instruction Manual TABLE OF CONTENTS IEC Symbols...2 Important Safeguards...2 Introduction...3 Specifications...4

More information

Aerobic Lateral Trainer

Aerobic Lateral Trainer Aerobic Lateral Trainer Assembly Manual HLT2500 IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THIS OWNER S MANUAL CONTAINS ASSEMBLY, OPERATION, MAINTENANCE AND SAFETY INFORMATION. IN

More information

MARCY Foldable Bike NS-652. Model NS-652. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC.

MARCY Foldable Bike NS-652. Model NS-652. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC. NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Hardware Pack Assembly Instruction Parts List MARCY Foldable Bike NS-652 Warranty Ordering Parts Model

More information

With extended functionality the sensors are also applicable for the detection of air bubbles.

With extended functionality the sensors are also applicable for the detection of air bubbles. Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality

More information

Multipower. User Guide E S S E N T I A L S T R E N G T H

Multipower. User Guide E S S E N T I A L S T R E N G T H E L E M E N T E S S E N T I A L S T R E N G T H User Guide The identification plate of and manufacturer, affixed to the frame behind the barbell rack, gives the following details: A B C D E Name and address

More information

GE Measurement & Control. Model C-ET. Ultrasonic Flow Transducer System. Installation Guide

GE Measurement & Control. Model C-ET. Ultrasonic Flow Transducer System. Installation Guide GE Measurement & Control Model C-ET Ultrasonic Flow Transducer System Installation Guide 916-083 Rev. B January 2013 Model C-ET Ultrasonic Flow Transducer System Installation Guide 916-083 Rev. B January

More information

The specifications of this product may vary from this photo and are subject to change without notice. For Customer Service, please contact:

The specifications of this product may vary from this photo and are subject to change without notice. For Customer Service, please contact: Elliptical Bike SF-E1114 The specifications of this product may vary from this photo and are subject to change without notice. For Customer Service, please contact: support@sunnyhealthfitness.com. Important

More information

FLAT BENCH SB Model SB Retain This Manual for Reference OWNER'S MANUAL

FLAT BENCH SB Model SB Retain This Manual for Reference OWNER'S MANUAL NOTE: Please read all instructions carefully before using this product Table of Contents FLAT BENCH SB-10510 Safety Notice Important Assembly Information Care and Maintenance Parts List Warranty Ordering

More information

STRUKTURA T01-A INSTALLATION INSTRUCTIONS TOP INLET AND REAR INLET FLOOR STANDING URINAL K-5889T-ER/K-5889T-ET

STRUKTURA T01-A INSTALLATION INSTRUCTIONS TOP INLET AND REAR INLET FLOOR STANDING URINAL K-5889T-ER/K-5889T-ET STRUKTURA INSTALLATION INSTRUCTIONS TOP INLET AND REAR INLET FLOOR STANDING URINAL K-5889T-ER/K-5889T-ET BEFORE YOU BEGIN Please read these instructions carefully to familiarize yourself with the required

More information

6 Submersible Turbine Pump

6 Submersible Turbine Pump 6 Submersible Turbine Pump 100 to 375 GPM PAGE: SP-200 Model Number Explanation Example: 175ST10D6B-0464 175 = GPM ST = Sub Turbine 10 = Horsepower D = Ductile Iron 6 = 6 Pump B = Impeller Trim 04 = Number

More information

Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR

Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR Innovative Sound Solutions TM Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR Presented by Benjamin Fried May, 2006 CTRL Systems, Inc. 1004 Littlestown Pike, Suite H Westminster, MD 21157

More information