1 BioGraph Infiniti DynaMap Suite 3.0 for ProComp Infiniti March 2, 2006 SA7990B Ver 3.0
2 DynaMap Suite 3.0 for ProComp Infiniti Contents List P Inf 8 Ch EMG Bi-Lateral Difference.chs 3 P Inf 8 Ch EMG.chs 4 P Inf 8 Ch Legs.chs 5 P Inf 5 Ch Multi Modality.chs 6 P Inf 4 Ch EMG 2 Goni 2 Force.chs 7 P Inf Force Calibration.chs 8 P Inf Goniometer Calibration.chs 9 P Inf Force Calibration.scr 10 P Inf Goniometer Calibration.scr 11 P Inf 2 Ch Raw Separated Graphs.scr 12 P Inf 2 Ch Raw Graphs Dual Screen.scr 13 P Inf 2 Ch Raw.scr 14 P Inf Ch A Test.scr (also B) 15 P Inf Ch C Test.scr (also D, E, F, G, H) 16 P Inf 2 Ch Spectral.scr 17 P Inf 8 Ch RMS.scr 18 P Inf 8 Ch RMS Bargraphs.scr 19 P Inf 8 Ch Line & Bar.scr 20 P Inf A and B RMS.scr (also C/D, E/F, G/H) 21 P Inf RMS A and B FFT.scr 22 P Inf 8 Ch RMS with Video.scr 23 P Inf 4 Ch RMS 2 Goni 2 Force.scr 24 P Inf EMG, Force, Goni, Video Dual Screen.scr 25 P Inf 2 Axis Goniometer.scr 26 P Inf 2 Ch Review RAW.scr 27 P Inf 2 Ch Review RAW Dual Screen with Video.scr 28 P Inf 8 Ch Review RMS.scr 29 P Inf 2 Ch Review Median Frequency.scr 30 P Inf 2 Ch Median Freq.scr 31 P Inf 2 Ch Median Freq with Video.scr 32 P Inf 1 Ch Median Freq with Log.scr 33 P Inf 2 Ch Bi-Lateral.scr 34 P Inf 8 Ch Bi-Lateral Bars.scr 35 P Inf 8 Ch Bi-Lateral + Video.scr 36 P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) 37 P Inf 8 Ch Bi-Lateral Back.scr 38 P Inf Para-spinal muscle activity.scr 39 P Inf Para-spinal and cervical comparison.scr 40 P Inf 5 Ch Multi Modality Overview.scr 41 P Inf 1 Ch EKG.scr 42 P Inf 2 Ch SC, Temp.scr 43 P Inf 2 Ch EMG.scr 44 P Inf 8 Ch Seated Iso + Anim.scr 45 Recuired Files for DynaMap Suite 3.0 for ProComp infiniti 46
3 Channel Sets P Inf 8 Ch EMG Bi-Lateral Difference.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan- Pro 400 D. MyoScan- Pro 400 E. MyoScan- Pro 400 F. MyoScan- Pro 400 G. MyoScan- Pro 400 H. MyoScan- Pro 400 This channel set is designed with bi-lateral pairs of electrodes in mind, in placements such as the lumbar region. Two MyoScan-Flex channels is filtered with a notch, then a high pass IIR filter that is set by default to 0.5Hz this can be increased to filter out heart artifact if it becomes evident in the signal. It is converted from the raw state to an RMS value using the non-sliding window algorithm, with a time period of one second and an averaging factor of 10. For looking at the spectral of the signals it is converted by an FFT. The MyoScan-Pro sensor automatically converts SEMG signal to a root mean square (RMS) signal (an analog rectification is done inside the circuitry). The logic to determine if the signals have a difference greater than 20% is the following:- e.g. between channel A and B. (A > B + B x 0.2 OR A < B B x 0.2 ) OR (B > A + A x 0.2 OR B < A A x 0.2 ) To enable easy adjustment of the percentage difference all of the channels have been ganged together and converted into a real number. By changing the constant value of the channel labeled Insert % Difference Value Here from the default 20 to 30 the percentage used in all the channels will be changed to 30%. This Boolean output is then converted to a float and optionally smoothed for use in an instrument. This smoothed output is used in all the screens supplied with this channel set. An additional level of logic is added to the channel set to prevent small levels of environmental electronic noise from changing the value for the output. This logic looks at the level of the two signals and if it is below 2uV then it does not calculate the 20% difference, and the out put remains at 0 or the light off. Note 1: Smoothing has been added to some of the digital and animated bar graphs to enhance the clinical feedback. Smoothing has not been added to the red indicator lights, this smoothing delay can lead to a slight miss match between the numbers seen and the illumination of the light. Note 2: The frequency of Notch filter is necessary to set from the Biograph Infiniti application before recording a session by selecting Options, Notch Filters then 60Hz or 50 Hz. 3
4 P Inf 8 Ch EMG.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan- Pro 400 D. MyoScan- Pro 400 E. MyoScan- Pro 400 F. MyoScan- Pro 400 G. MyoScan- Pro 400 H. MyoScan- Pro 400 Two MyoScan-Flex channels are filtered once through a notch filter to remove 60 Hz or 50 Hz noise, and then through a IIR high pass filter set to 20 Hz, this can be increased in the main application to 100 Hz to eliminate the heart rate artifact that may be detected when the electrodes are used in a number of locations. FFT, RMS, Median Frequency (MF), MF smoothed, Peak Frequency, Maximum, Minimum, Mean, Standard Deviation, Minimum MF, Variability, Mean MF are calculated for 2 channels. Six other channels are used to connect MyoScan- Pro sensors.. The MyoScan-Pro sensor automatically converts SEMG signal to a root mean square (RMS) signal (an analog rectification is done inside the circuitry). Maximum, Minimum, Mean, Standard Deviation, Variability are calculated for 6 MyoScan-Pro channels. 4
5 P Inf 8 Ch Legs.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan-Pro 400 D. MyoScan-Pro 400 E. MyoScan-Pro 400 F. MyoScan-Pro 400 G. Goniometer H. Goniometer A collection of channels intended for the monitoring of dual leg activity and angle. Standard signal processing of the EMG signals. Goniometer channels are processed through a linear transform, enabling the calibration by the user. 5
6 P Inf 5 Ch Multi Modality.chs A. MyoScan-Flex B. MyoScan-Flex C. EKG-Pro/Flex D. Temp-Pro/Flex E. SC-Pro/Flex A mix of modalities to enable monitoring physiology and EMG simultaneously. Standard filtering on the EMG signal, with Notch and High Pass IIR filter and RMS and FFT calculations. EKG processed to detect the inter beat interval, from this Heart Rate is calculated and an FFT to look at the power spectrum. Temperature and Skin Conductance are also recorded and statistical values extracted. 6
7 P Inf 4 Ch EMG 2 Goni 2 Force.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan-Pro 400 D. MyoScan-Pro 400 E. Force F. Force G. Goniometer H. Goniometer I. Alternative arrangement of sensors inputs, processing for each channel as described above. Note: - Goniometers and Torsiometers are interchangeable in the software. Goniometer, Torsiometer and Force sensors are all fed through a linear transform equation that is accessible within the main application. The input max and min values are correlated to the desired and calibrated output values. Sensors that are not connected at time of recording are automatically set to a raw input value of 1. If this channel is then processed through a linear transform virtual channel it may result in a constant value different from 1, and will display as such on the display screen. 7
8 P Inf Force Calibration.chs A. Force B. Force C. Force D. Force E. Force F. Force G. Force H. Force All Force channels are intended for calibrating Force sensors. 8
9 P Inf Goniometer Calibration.chs A. Goniometer B. Goniometer C. Goniometer D. Goniometer E. Goniometer F. Goniometer G. Goniometer H. Goniometer All Goniometer channels are intended for calibrating Goniometer/ Torsiometer sensors. 9
10 P Inf Force Calibration.scr Channel Set: P Inf Force Calibration.chs Category: Calibration Description: Force Calibration. Screen intended for force sensors calibration. To calibrate the sensors, connect the hardware and open the Force calibration screen then start a recording. Apply a know load to the force sensor and record the loaded (max) and unloaded (min). Stop the session and move to the channel set that is going to be used to record data, edit the virtual channel set and select the virtual channel relating to the sensor that you are calibrating. Manually enter the input Min and Max values and the corresponding output min and max values of the known load. It is also possible to enter the units of measure which will appear in generated reports. Note: - A force sensor converts the load applied to a raw value, as the load changes the value corresponding to that load changes with it. This raw value can be transformed into a meaningful calibrated value in the software by using the linear transform virtual channel. This linear transform takes the minimum and maximum raw value and converts it to the min-max output values corresponding to the positions (e.g to 845 becomes 0 to 10 lbs). 10
11 P Inf Goniometer Calibration.scr Channel Set: P Inf Goniometer Calibration.chs Category: Calibration Description: Goniometer Calibration. Screen intended for goniometer sensors calibration. To calibrate the sensors, connect the hardware and open the goniometer calibration screen then start a recording. Manipulate the goniometer to its maximum and minimum specified deflection. Record the max and min values. Stop the session and move to the channel set that is going to be used to record data, edit the virtual channel set and select the virtual channel relating to the axis that you are calibrating. Manually enter the input Min and Max values and the corresponding output min and max values. It is also possible to enter the units of measure which will appear in generated reports. Note: -.A goniometer sensor converts its position to a raw value, as the position changes the value corresponding to that position changes with it. Most goniometers have a specified minimum and maximum deflection. This raw value can be transformed into a meaningful calibrated value in the software by using the linear transform virtual channel. This linear transform takes the minimum and maximum raw value and converts it to the min-max output values corresponding to the positions (e.g to 70 becomes 0 to 180 Degrees.) 11
12 P Inf 2 Ch Raw Separated Graphs.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of RAW EMG each on its own line graph. No feedback. 12
13 P Inf 2 Ch Raw Graphs Dual Screen.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw Two screens containing 2 channels of RAW EMG each on its own line graph, a digital readout of each channel converted to RMS. Video to display from the web cam. No feedback 13
14 P Inf 2 Ch Raw.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of RAW EMG on multi line graph. No feedback. 14
15 P Inf Ch A Test.scr (also B) Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: Test screen Ch A A sample of information from the output of channel A. Raw Line graph, RMS line Graph, Max, Mean, Min, Std Deviation, Variability stats, and Median and Peak Frequencies and a 2D power spectrum. This screen has been duplicated for channel B. 15
16 P Inf Ch C Test.scr (also D, E, F, G, H) Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: Test screen Ch C A sample of information from the output of channel C. RMS line Graph, Max, Mean, Min, Std Deviation, Variability stats. This screen has been duplicated for D, E, F, G, H channels as a test of each channel. 16
17 P Inf 2 Ch Spectral.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of Spectral from Raw EMG divided bilaterally two signals left and right per spectral display with RMS EMG bargraphs for each channel at the side. 17
18 P Inf 8 Ch RMS.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS 8 channels of RMS data shown in bi-lateral pairs on multi line graphs. 18
19 P Inf 8 Ch RMS Bargraphs.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS Bargraphs 8 Channels of RMS data shown in multiple bar graphs with digital display of value. 19
20 P Inf 8 Ch Line & Bar.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS Line Graph and Bar Graphs. 8 Channels of RMS data derived from the 2 RAW inputs (Channels A and B) and 6 RMS inputs (channels C, D, E, F, G, H) shown in 2 line graphs for signals A,B and bar graphs for the other 6 signals. 20
21 P Inf A and B RMS.scr (also C/D, E/F, G/H) Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 2 Ch RMS A and B 2 channels of RMS data shown in a line graph. This screen has been duplicated for the other 3 pairs of channels. 21
22 P Inf RMS A and B FFT.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 2 Ch RMS A and B with 3D FFT display. 2 Channels of RMS data derived from the channels A and B RAW inputs to the ProComp shown in a line graph. 22
23 P Inf 8 Ch RMS with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS with Video. 8 channels of RMS data shown in line graphs. It also shows a single video view. 23
24 P Inf 4 Ch RMS 2 Goni 2 Force.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: General Description: 4 Ch of EMG with Force and Goniometers. Two line graphs showing RMS EMG signals and two line graphs one for Goniometer dual axis and one for two force sensors. 24
25 P Inf EMG, Force, Goni, Video Dual Screen.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: General Description: 4 Ch of EMG with Force and Goniometers. Two line graphs showing RMS EMG signals and two line graphs one for Goniometer dual axis and one for two force sensors. Extended onto a second screen which displays a video display 25
26 P Inf 2 Axis Goniometer.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: Goniometer Description: 2 Axis Goniometer. 2 Channels of dual axis goniometer displayed on line graph. 26
27 P Inf 2 Ch Review RAW.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Raw with stats for review. 2 Ch EMG review with RAW line graphs shown. 27
28 P Inf 2 Ch Review RAW Dual Screen with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Raw with stats for review. 2 Ch EMG review with RAW line graphs shown, with the addition of a dual screen and a video display. 28
29 P Inf 8 Ch Review RMS.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 8 Ch RMS with stats for review. 8 channel review screen, with instruction. RMS data shown. 29
30 P Inf 2 Ch Review Median Frequency.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Median Freq with stats for review. 2 channel review screen, with instruction. Median Frequency data shown. By moving the vertical red cursor available in the review mode it is possible to view statistics in the table above corresponding to any part of the session displayed as Median Frequency in the lower screens. The Median Frequency displayed in the table and the line graphs is smoothed to decrease the rapid changes and show a better trend. 30
31 P Inf 2 Ch Median Freq.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 2 Ch Median Freq with stats for recording. 2 Channel recording screen, for looking at interplay of median frequency and RMS data between two bilateral sites. Median Frequency data shown. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. 31
32 P Inf 2 Ch Median Freq with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 2 Ch Median Freq with stats for recording. 2 Channel recording screen, for looking at interplay of median frequency and RMS data between two bilateral sites. Median Frequency data shown. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. Dual screen with video and larger graphing spaces. 32
33 P Inf 1 Ch Median Freq with Log.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 1 Ch Median Freq with histogram. 1 Channel recording screen, for looking at a trend of median frequency and RMS data over a clinical session. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. By changing the settings for the comparator virtual channel it is possible to trigger on the rising or falling edge of the RMS. 33
34 P Inf 2 Ch Bi-Lateral.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 2 Ch of Bi-Lateral difference. One pairs of channels A vs B, showing difference when greater than 20% indicated by lights turning red. Linegraphs showing RMS SEMG of each muscle site. 34
35 P Inf 8 Ch Bi-Lateral Bars.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, and G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 35
36 P Inf 8 Ch Bi-Lateral + Video.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. Includes video display to show web cam footage. 36
37 P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 2 Ch A - B of Bi-Lateral difference with Video. One pair of channels A vs B, showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Animated bars and digital displays showing RMS SEMG of each muscle site. Video enables viewing of the motion performed. 37
38 P Inf 8 Ch Bi-Lateral Back.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, and G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site 38
39 P Inf Para-spinal muscle activity.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: Bilateral comparison of para-spinal muscle activity. Five pairs of channels A vs B at C7 T1, C vs D at T6 T7, E vs F at T12 L1, G vs H at L2 L3, Bi-lateral difference when greater than 20% is indicated by lights turning red. Designed with the intent of evaluating para-spinal muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 39
40 P Inf Para-spinal and cervical comparison.scr Channel Set: F Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: Para-spinal and cervical muscle activity. Five pairs of channels A vs B at C2 C3, C vs D at C7 T1, E vs F at T6 T7, G vs H at T12 L1, Bi-lateral difference when greater than 20% is indicated by lights turning red. Designed with the intent of evaluating para-spinal including cervical muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 40
41 P Inf 5 Ch Multi Modality Overview.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: Overview of Signals. A multi-modality use of the ProComp encoder, this channel set and screen presents data from the EMG, EKG, Temp and Skin Conductance sensors. EKG Heart Rate, IBI, Max, Min Mean, Peak Freq, Std Dev in Heart Rate. Temp Max, Min, Mean, Real Time. SC Mean, Real Time EMG Two channels of real time RMS EMG and the Mean for each channel. 41
42 P Inf 1 Ch EKG.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: EKG Overview of Signals. Focusing on EKG and heart rate, this screen shows in line graphs both the heart rate and the raw EMG signal. Standard Deviation of the heart rate is shown as a bar graph on the right of the screen. A Fast Fourier Transform of the inter-beat interval (IBI) is displayed in both a 3D and a 2D power spectrum, to accompany these there is a digital display showing the peak frequency. Real-time measurements of Heart Rate, IBI, Max, Min and Mean Heart Rates are also displayed. 42
43 P Inf 2 Ch SC, Temp.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: SC, Temp Overview of Signals. This screen shows in line graphs both the Temperature and Skin Conductance. Real-time measurements of Temperature, Skin Conductance, Max, Min and Mean are also displayed. 43
44 P Inf 2 Ch EMG.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: EMG, Temp Overview of Signals. Focusing on EMG, this screen shows in line graphs both the RMS and the raw EMG signal. 2D Power Spectrums show the result of the FFT performed on the two channels. Real-time measurements of RMS, Max, Min and Mean are displayed. 44
45 P Inf 8 Ch Seated Iso + Anim.scr Channel Set: P Inf 8 Ch Legs.chs Category: Goniometer Description: EMG and Goniometer for leg evaluation Focusing on EMG activity and angle of the knee when subject is seated during extension and flexion, this screen displaying the placement and RMS readings from six EMG sensors, and Goniometer. Placement is on the Quadriceps Femoris, Vastus Lateralis and the Vastus Medialis. This screen can be used with others in the leg series to give an integrated view of the leg as a whole. Animation works with the client, as they move their leg the animation moves. Set the animation scale to the max min readings of goniometer G. 45
46 Recuired Files for DynaMap Suite 3.0 for ProComp infiniti Channel Sets (.chs ) P Inf 8 Ch EMG.chs P Inf 8 Ch EMG Bi-Lateral Difference.chs P Inf 8 Ch Legs.chs P Inf 5 Ch Multi Modality.chs P Inf 4 Ch EMG 2 Goni 2 Force.chs P Inf Force Calibration.chs P Inf Goniometer Calibration.chs Screens (.scr ) P Inf Force Calibration.scr P Inf Goniometer Calibration.scr P Inf 2 Ch Raw Separated Graphs.scr P Inf 2 Ch Raw Graphs Dual Screen.scr P Inf 2 Ch Raw.scr P Inf Ch A Test.scr (also B) P Inf Ch C Test.scr (also D, E, F, G, H) P Inf 2 Ch Spectral.scr P Inf 8 Ch RMS.scr P Inf 8 Ch RMS Bargraphs.scr P Inf 8 Ch Line & Bar.scr P Inf A and B RMS.scr (also C/D, E/F, G/H) P Inf RMS A and B FFT.scr P Inf 8 Ch RMS with Video.scr P Inf 4 Ch RMS 2 Goni 2 Force.scr P Inf EMG, Force, Goni, Video Dual Screen.scr P Inf 2 Axis Goniometer.scr P Inf 2 Ch Review RAW.scr P Inf 2 Ch Review RAW Dual Screen with Video.scr P Inf 8 Ch Review RMS.scr P Inf 2 Ch Review Median Frequency.scr P Inf 2 Ch Median Freq.scr P Inf 2 Ch Median Freq with Video.scr P Inf 1 Ch Median Freq with Log.scr P Inf 2 Ch Bi-Lateral.scr P Inf 8 Ch Bi-Lateral Bars.scr P Inf 8 Ch Bi-Lateral + Video.scr P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) P Inf 8 Ch Bi-Lateral Back.scr P Inf Para-spinal muscle activity.scr P Inf Para-spinal and cervical comparison.scr P Inf 5 Ch Multi Modality Overview.scr P Inf 1 Ch EKG.scr P Inf 2 Ch SC, Temp.scr 46
47 P Inf 2 Ch EMG.scr P Inf 8 Ch Seated Iso + Anim.scr Animations Linear R to L Rainbow Bar.avi Linear L to R Rainbow Bar.avi Man with leg flex.avi Binary Red Light.avi Pictures back.bmp 47
BioGraph Infiniti DynaMap Suite 3.0 for FlexComp Infiniti March 2, SA7990A Ver 3.0
BioGraph Infiniti DynaMap Suite 3.0 for FlexComp Infiniti March 2, 2006 SA7990A Ver 3.0 DynaMap Suite 3.0 for FlexComp Infiniti Contents List F Inf 10 Ch EMG Bi-Lateral Difference.chs 3 F Inf 10 Ch EMG.chs
More informationThought Technology Ltd.
Thought Technology Ltd. 8205 Montreal/ Toronto Blvd. Suite 223, Montreal West, QC H4X 1N1 Canada Tel: (800) 361-3651 ۰ (514) 489-8251 Fax: (514) 489-8255 E-mail: mail@thoughttechnology.com Webpage: http://www.thoughttechnology.com
More informationMES 9000 MUSCULOSKELETAL EVALUATION SYSTEM
MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM The new MES 9000. Now you can completely and objectively evaluate and document Dynamic Range of Motion, Static and Dynamic EMG and Muscle Testing All with one
More informationFUSE TECHNICAL REPORT
FUSE TECHNICAL REPORT 1 / 16 Contents Page 3 Page 4 Page 8 Page 10 Page 13 Page 16 Introduction FUSE Accuracy Validation Testing LBD Risk Score Model Details FUSE Risk Score Implementation Details FUSE
More informationSoftware Overview. Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada
Software Overview Thought Technology Ltd. 2180 Belgrave Avenue, Montreal, QC H4A 2L8 Canada Tel: +1 (800) 361-3651 ٠ +1 (514) 489-8251 Fax: +1 (514) 489-8255 E-mail: mail@thoughttechnology.com Webpage:
More informationSupplementary Figure S1: Histological analysis of kainate-treated animals
Supplementary Figure S1: Histological analysis of kainate-treated animals Nissl stained coronal or horizontal sections were made from kainate injected (right) and saline injected (left) animals at different
More informationOverview. Page 1 of 9. Impedance Cardiography
Updated 05.14.10 BSL PRO Lesson H21: Impedance Cardiography Data collected from a subject using the referenced set-up procedure. Note that dz/dt maximum is determined on a cycle by cycle basis from the
More informationRaw BP and Eight Hemodynamic Measurements Displayed in Real Time
APPLICATION NOTE 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com Updated 01.11.2016 Application Note 115: Hemodynamic Measurements Raw BP and Eight
More informationAccuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.
Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards. Prepared by Engineering and Human Performance Lab Department of
More informationAngular Measurements with BIOPAC Goniometers & Torsiometers
APPLICATION NOTES 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com support@.biopac.com Application Note 140 Angular Measurements with BIOPAC Goniometers & Torsiometers
More informationHybrid EEG-HEG based Neurofeedback Device
APSIPA ASC 2011 Xi an Hybrid EEG-HEG based Neurofeedback Device Supassorn Rodrak *, Supatcha Namtong, and Yodchanan Wongsawat ** Department of Biomedical Engineering, Faculty of Engineering, Mahidol University,
More informationDrug Free Stress Management using Biofeedback by
John C Coates ND CHt Melbourne Victoria Australia Biofeedback Practitioner Hypnotherapist Naturopath Herbalist Kinesiologist Telephone: 0402 309 534 Email: coates.john1@gmail.com Drug Free Stress Management
More informationStationary regime for Standing Wave Central Pattern Generator
Stationary regime for Standing Wave Central Pattern Generator Roberto Martin-del-Campo & Edmond Jonckheere Presenter: Roberto Martin-del-Campo 3 rd IEEE Global Conference on Signal & Information Processing
More informationEMG-Driven Human Model for Orthosis Control
EMG-Driven Human Model for Orthosis Control Christian Fleischer, Günter Hommel Institute for Computer Engineering and Microelectronics Berlin University of Technology, Germany {fleischer, hommel}@cs.tu-berlin.de
More information11/18/13 ECG SIGNAL ACQUISITION HARDWARE DESIGN. Origin of Bioelectric Signals
ECG SIGNAL ACQUISITION HARDWARE DESIGN Origin of Bioelectric Signals 1 Cell membrane, channel proteins Electrical and chemical gradients at the semi-permeable cell membrane As a result, we get a membrane
More informationFES Standing: The Effect of Arm Support on Stability and Fatigue During Sit-to-Stand Manoeuvres in SCI Individuals
FES Standing: The Effect of Arm Support on Stability and Fatigue During Sit-to-Stand Manoeuvres in SCI Individuals Musfirah Abd Aziz and Nur Azah Hamzaid Abstract Functional Electrical Stimulation (FES)
More informationAnalysis of EMG Signal to Evaluate Muscle Strength and Classification
Analysis of EMG Signal to Evaluate Muscle Strength and Classification Kiran K. 1, Uma Rani K. 2 1MTech Student, Biomedical Signal Processing and Instrumentation, Dept. of IT, SJCE, Mysuru, Karnataka, India
More informationProcessed by HBI: Russia/Switzerland/USA
1 CONTENTS I Personal and clinical data II Conclusion. III Recommendations for therapy IV Report. 1. Procedures of EEG recording and analysis 2. Search for paroxysms 3. Eyes Open background EEG rhythms
More informationElectroencephalograph EEG-9200J/K
Electroencephalograph EEG-9200J/K Efficient and user-friendly EEG-9200 is a Windows XP desktop PC based electroencephalograph that is efficient and easy to use with 8 ch DSA trendgraph, 3D mapping, high
More informationDynamic Surface Electromyography (SEMG) Information Sheet
Dynamic Surface Electromyography (SEMG) Information Sheet Dynamic surface electromyography (SEMG) measures the electrical activity that muscles exhibit when in use. It is an objective diagnostic tool that
More informationBSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject
Updated 12-22-03 BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject This PRO lesson describes hardware and software setup of the BSL PRO System to record and measure
More informationSoftware Manual. Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada
Software Manual Thought Technology Ltd. 2180 Belgrave Avenue, Montreal, QC H4A 2L8 Canada Tel: +1 (800) 361-3651 ٠ +1 (514) 489-8251 Fax: +1 (514) 489-8255 E-mail: mail@thoughttechnology.com Webpage: http://www.thoughttechnology.com
More informationFeasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011
Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Electrical and Computer Engineering Department Volgenau School of Engineering George
More informationHuman Brain Institute Russia-Switzerland-USA
1 Human Brain Institute Russia-Switzerland-USA CONTENTS I Personal and clinical data II Conclusion. III Recommendations for therapy IV Report. 1. Procedures of EEG recording and analysis 2. Search for
More informationBiopac Student Lab Lesson 20 SPINAL CORD REFLEXES Analysis Procedure. Rev
42 Aero Camino, Goleta, CA 93117 www.biopac.com Biopac Student Lab Lesson 20 SPINAL CORD REFLEXES Analysis Procedure Rev. 12292017 Richard Pflanzer, Ph.D. Associate Professor Emeritus Indiana University
More informationAn electrocardiogram (ECG) is a recording of the electricity of the heart. Analysis of ECG
Introduction An electrocardiogram (ECG) is a recording of the electricity of the heart. Analysis of ECG data can give important information about the health of the heart and can help physicians to diagnose
More informationHand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited
Hand of Hope For hand rehabilitation Member of Vincent Medical Holdings Limited Over 17 Million people worldwide suffer a stroke each year A stroke is the largest cause of a disability with half of all
More informationExtraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image
International Journal of Research Studies in Science, Engineering and Technology Volume 1, Issue 5, August 2014, PP 1-7 ISSN 2349-4751 (Print) & ISSN 2349-476X (Online) Extraction of Blood Vessels and
More informationFT-302 Force Transducer
Technical Note FT-302 LabScribe is a trademark of 2015 Overview The FT-302 is a high-sensitivity dual-range research grade force transducer designed to measure forces in the 0.005 to 10 gram and 0 to 100
More informationInstruction Manual No A. Goniometer PS-2138, PS-2137
Instruction Manual No. 012-08904A Goniometer PS-2138, PS-2137 Goniometer Model No. PS-2138 Contents Introduction......................................................... 3 Probe Mounting......................................................
More informationErgonomic Test of the Kinesis Contoured Keyboard
Global Ergonomic Technologies, Inc. Ergonomic Test of the Kinesis Contoured Keyboard Prepared by Wanda Smith, President Dan Cronin, Engineer December 16, 1992 Executive Summary A study was conducted of
More informationExperiment HM-7: Electromyogram (EMG) Activity in Antagonistic Muscles and Range of Motion
Experiment HM-7: Electromyogram (EMG) Activity in Antagonistic Muscles and Range of Motion Exercise 1: Antagonistic Muscles in Forearm Aim: To study the EMG activity in muscles that work in opposition
More information6 Correlation of Biometric Variables Measured with Biograph Infinity Biofeedback Device and Psychometric Scores of Burnout and Anxiety
6-1 6 Correlation of Biometric Variables Measured with Biograph Infinity Biofeedback Device and Psychometric Scores of Burnout and Anxiety 6.1 Background The Procomp Infinity encoder and Biograph Infinity
More informationECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR
ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR Screening and Clinical Modality User Programmable Protocols ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR All of Labat s technology
More informationStep-by-Step RECD Guide
Precision Audiometric Instruments www.medrx-usa.com Step-by-Step RECD Guide The RECD task involves 4 steps: 1 - Complete Calibration of the Speakers and Probe Tube 2 - Measure an Ear Response 3 - Perform
More informationHow to use AutoFit (IMC2) How to use AutoFit (IMC2)
How to use AutoFit (IMC2) 1 AutoFit is a beneficial feature in the Connexx Fitting Application that automatically provides the Hearing Care Professional (HCP) with an optimized real-ear insertion gain
More informationEarly Learning vs Early Variability 1.5 r = p = Early Learning r = p = e 005. Early Learning 0.
The temporal structure of motor variability is dynamically regulated and predicts individual differences in motor learning ability Howard Wu *, Yohsuke Miyamoto *, Luis Nicolas Gonzales-Castro, Bence P.
More informationEffect of Patellar Taping on Quadriceps Muscle of Knee Joint INTRODUCTION
Effect of Patellar Taping on Quadriceps Muscle of Knee Joint INTRODUCTION 406 METHODS 407 S.E. Lee, S.G. Kim, S.h. Cho, et al. keep for 5sec and rest for 30sec, which is repeated three times. After exercise,
More informationTheta sequences are essential for internally generated hippocampal firing fields.
Theta sequences are essential for internally generated hippocampal firing fields. Yingxue Wang, Sandro Romani, Brian Lustig, Anthony Leonardo, Eva Pastalkova Supplementary Materials Supplementary Modeling
More informationDevelopment of an Electronic Glove with Voice Output for Finger Posture Recognition
Development of an Electronic Glove with Voice Output for Finger Posture Recognition F. Wong*, E. H. Loh, P. Y. Lim, R. R. Porle, R. Chin, K. Teo and K. A. Mohamad Faculty of Engineering, Universiti Malaysia
More informationGeneral Treatment Equipment
General Treatment Equipment We have quality products in General Treatment Equipment. All our models are efficient and display quality in Panchakarma (Ayurvedic) products. IMI - 3111: EXAMINATION COUCH
More informationThe Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements
The Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements By: Kristina Frye Section 1: Common Source Types FONIX analyzers contain two main signal types: Puretone and
More informationMassage and Movement. Patrick A. Ward, MS CSCS LMT OptimumSportsPerformance.com
Massage and Movement Patrick A. Ward, MS CSCS LMT OptimumSportsPerformance.com Massage and Movement Massage comes in all kinds of varieties. From spa massage, to clinical/treatment based massage, to the
More informationTMG - BMC LTD. Mirje 6 Tel: ( ) Ljubljana Fax: ( ) TENSIOMYOGRAPHY (TMG) MEASUREMENT RESULTS
TMG - BMC LTD. Mirje 6 Tel: (00 386 1) 4210 037 1000 Ljubljana Fax: (00 386 1) 2425 382 Slovenia Email: info@tmg.si Europe (EU) Web: www.tmg.si TENSIOMYOGRAPHY (TMG) MEASUREMENT RESULTS Subject: Adrian
More informationHumerus. Ulna. Radius. Carpals
Posture Analysis Exercise T. Armstrong M. Ebersole 1.0 Objectives: 1. Improve skill for rating over all job and identifying specific force and posture problems 2. Learn how to characterize posture 3. Learn
More informationCorporate Medical Policy
Corporate Medical Policy Paraspinal Surface Electromyography (SEMG) File Name: Origination: Last CAP Review: Next CAP Review: Last Review: paraspinal_surface_electromyography_(emg) 4/2005 5/2018 5/2019
More informationAn Overview of BMIs. Luca Rossini. Workshop on Brain Machine Interfaces for Space Applications
An Overview of BMIs Luca Rossini Workshop on Brain Machine Interfaces for Space Applications European Space Research and Technology Centre, European Space Agency Noordvijk, 30 th November 2009 Definition
More informationISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 10, April 2013
ECG Processing &Arrhythmia Detection: An Attempt M.R. Mhetre 1, Advait Vaishampayan 2, Madhav Raskar 3 Instrumentation Engineering Department 1, 2, 3, Vishwakarma Institute of Technology, Pune, India Abstract
More informationPhotic Output control using BrainMaster Atlantis
Photic Output control using BrainMaster Atlantis Software version 3.5 (and later) December 17, 2009 December 17, 2009 Page 1 of 20 Table of Contents Introduction...3 Autonomous/Immersive Mode...5 PC Controlled
More informationELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION INTRODUCTION
ELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION STANDARDS: 3.3.10.B - Explain cell functions and processes in terms of chemical reactions and energy changes. 3.3.12.B - Evaluate relationships between structure
More informationCloud Condensation Nuclei Counter (CCN) Module
Particle Analysis and Display System (PADS): Cloud Condensation Nuclei Counter (CCN) Module Operator Manual DOC-0190 A-1 PADS 2.5.6, CCN Module 2.5.1 5710 Flatiron Parkway, Unit B Boulder, CO 80301 USA
More informationNature Neuroscience: doi: /nn Supplementary Figure 1
Supplementary Figure 1 Hippocampal recordings. a. (top) Post-operative MRI (left, depicting a depth electrode implanted along the longitudinal hippocampal axis) and co-registered preoperative MRI (right)
More informationMultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation
MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation Plexus and Epidural Anaesthesia The essential advantage regarding safety MultiStim SENSOR and MultiStim SWITCH With MultiStim
More informationCaptus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive
Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier. The Captus 3000 combines a software program with the
More informationMyoelectric control algorithm for robot assisted therapy: a hardware in the loop simulation study
https://doi.org/10.1186/s12938-018-0622-1 BioMedical Engineering OnLine RESEARCH Open Access Myoelectric control algorithm for robot assisted therapy: a hardware in the loop simulation study Juan C. Yepes
More informationBIOMECHANICAL ANALYSIS OF THE DEADLIFT DURING THE 1999 SPECIAL OLYMPICS WORLD GAMES
63 Biomechanics Symposia 2001 / University of San Francisco BIOMECHANICAL ANALYSIS OF THE DEADLIFT DURING THE 1999 SPECIAL OLYMPICS WORLD GAMES Rafael F. Escamilla, Tracy M. Lowry, Daryl C. Osbahr, and
More informationSleepSign System. FAQs User List Software Overview
FAQs User List Software Overview SleepSign System SSA100W SleepSign System - Frequently Asked Questions 1. Why should I use SleepSign software? 2. Can SleepSign import digital data generated from my BIOPAC
More informationSIGNATURE SERIES OLYMPIC FLAT BENCH
SIGNATURE SERIES OLYMPIC FLAT BENCH Machine Weight: 150 lbs Size: in. = 51L x 49W x 51H SIGNATURE SERIES OLYMPIC INCLINE BENCH Machine Weight: 185 lbs Size: in. = 51L x 58W x 57H > 30-degree back pad angle
More informationStats 95. Statistical analysis without compelling presentation is annoying at best and catastrophic at worst. From raw numbers to meaningful pictures
Stats 95 Statistical analysis without compelling presentation is annoying at best and catastrophic at worst. From raw numbers to meaningful pictures Stats 95 Why Stats? 200 countries over 200 years http://www.youtube.com/watch?v=jbksrlysojo
More informationE SERIES. Contents CALIBRATION PROCEDURE. Version 2.0
CALIBRATION PROCEDURE E SERIES Version 2.0 Contents Introduction Document Scope... 2 Calibration Overview... 3 What Is Calibration?... 3 Why Calibrate?... 3 How Often Should You Calibrate?... 3 What Can
More information8/20/ Identify the functions of common ECG machines. 3.3 Explain how each ECG machine control is used. 3.4 Recognize common electrodes.
1 2 Electrocardiography for Healthcare Professionals Chapter 3: The Electrocardiograph Learning Outcomes 3.1 Identify three types of leads, and explain how each is recorded. 3.2 Identify the functions
More informationCigarette Smoke Generator
Sophisticated Life Science Research Instrumentation Cigarette Smoke Generator For Inhalation and Analytic Studies Info@TSE-Systems.com Contents Cigarette Smoke Generator Fully Automatic 3 Sensors 3 Cigarette
More informationPOST-ACTIVATION POTENTIATION AND VERTICAL JUMP PERFORMANCE. Cody Hardwick
POST-ACTIVATION POTENTIATION AND VERTICAL JUMP PERFORMANCE Cody Hardwick Submitted in partial fulfillment of the requirements For the degree Master of Science in Kinesiology In the School of Public Health
More informationA Brain Computer Interface System For Auto Piloting Wheelchair
A Brain Computer Interface System For Auto Piloting Wheelchair Reshmi G, N. Kumaravel & M. Sasikala Centre for Medical Electronics, Dept. of Electronics and Communication Engineering, College of Engineering,
More informationTesting the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device
Testing the Accuracy of ECG Captured by through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device Data Analysis a) R-wave Comparison: The mean and standard deviation of R-wave amplitudes
More informationPosture Pump PENTAVEC Model 2500 Instructions
Posture Pump PENTAVEC Model 2500 Instructions page 1 of 6 TRAINING INSTRUCTIONS CAUTION: CAREFULLY READ AND ADJUST THE PELVIC AND FOOT-UNIT BELTS PER "ADJUSTING THE PELVIC PULL" INSTRUCTIONS ON THE FOLLOWING
More informationANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0
ANATOMIC Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0 SCREEN LAYOUT Take screenshot Surgical step Dynamic navigation zone Information area and buttons 2 SCREEN LAYOUT Indicates action when yellow
More informationLABVIEW based expert system for Detection of heart abnormalities
LABVIEW based expert system for Detection of heart abnormalities Saket Jain Piyush Kumar Monica Subashini.M School of Electrical Engineering VIT University, Vellore - 632014, Tamil Nadu, India Email address:
More informationExperiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation
Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation Background The arterial system functions as a pressure reservoir. Blood enters via the heart and exits through the capillaries.
More informationYou make us tic. Leading an active life... syntic. contic + biotic + The first choice in the device-assisted conservative therapy of incontinence
Leading an active life... p r e m i u m l i n e You make us tic syntic biotic + contic + The first choice in the device-assisted conservative therapy of incontinence Multifunctional and nevertheless customized...
More informationCHAPTER 4 ANFIS BASED TOTAL DEMAND DISTORTION FACTOR
47 CHAPTER 4 ANFIS BASED TOTAL DEMAND DISTORTION FACTOR In distribution systems, the current harmonic distortion should be limited to an acceptable limit to avoid heating, losses and malfunctioning of
More informationGeneral Single Ion Calibration. Pete 14-May-09
General Single Ion Calibration Pete 14-May-09 Purpose of SI calibration Measure the instrument response of a single ion. Necessary for understanding of error in instrument (counting statistics) Calculation
More informationHemodynamic Analysis System
Hemodynamic Analysis System Advisor: Professor Mitch Tyler Client: Professor Naomi Chesler Team members: Sarah Czaplewski, Megan Jones, Sara Schmitz, and William Zuleger Overview Pulmonary Hypertension
More informationElectromyography Segmented Assessment for Lower Limb Muscle Transition to Fatigue During Isometric Contraction
Electromyography Segmented Assessment for Lower Limb Muscle Transition to Fatigue During Isometric Contraction By Jorge Garza-Ulloa, Pablo Rangel, Olatunde Adeoye Department of Electrical and Computer
More informationSpeed - Accuracy - Exploration. Pathfinder SL
Speed - Accuracy - Exploration Pathfinder SL 98000 Speed. Accuracy. Exploration. Pathfinder SL represents the evolution of over 40 years of technology, design, algorithm development and experience in the
More informationSINCE 1978 MADE IN THE USA PRO 7000 SERIES SUPPLEMENTARY MACHINES MEDICAL SERIES. engineered for success
SINCE 1978 MADE IN THE USA 1 TM PRO 7000 SERIES SUPPLEMENTARY MACHINES MEDICAL SERIES ENGINEERED FOR SPORTS PERFORMANCE MAGNUM S PRO 7000 SERIES Thirty years of industry experience, innovation, and customer
More informationProtein quantitation guidance (SXHL288)
Protein quantitation guidance (SXHL288) You may find it helpful to print this document and have it to hand as you work onscreen with the spectrophotometer. Contents 1. Introduction... 1 2. Protein Assay...
More informationLIGHTING LABORATORY TESTING SERVICES EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS V1015W
LIGHTING LABORATORY TESTING SERVICES V1015W EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS ABOUT THE LAB The Energywise Lighting Laboratory is offering complete photometric, electric and thermal testing
More informationIso-inertial dynamometer
Iso-inertial dynamometer A. Equipment set up B. Data acquisition and export C. Training mode 1 P a g e A. Equipment set up 1. Connect all the devices as depicted below: 2. Launch the software by clicking
More informationOutline of Talk. Introduction to EEG and Event Related Potentials. Key points. My path to EEG
Outline of Talk Introduction to EEG and Event Related Potentials Shafali Spurling Jeste Assistant Professor in Psychiatry and Neurology UCLA Center for Autism Research and Treatment Basic definitions and
More informationLesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG
Physiology Lessons for use with the PC running Windows 98SE, Me, 2000 Pro, XP Pro/Home/Media Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG Manual Revision PL3.7.0 080706 Richard Pflanzer, Ph.D.
More informationPhysiology Lessons for use with the Biopac Student Lab. Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG
Physiology Lessons for use with the Biopac Student Lab Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG Richard Pflanzer, Ph.D. Associate Professor Emeritus Indiana University School of Medicine
More informationCSDplotter user guide Klas H. Pettersen
CSDplotter user guide Klas H. Pettersen [CSDplotter user guide] [0.1.1] [version: 23/05-2006] 1 Table of Contents Copyright...3 Feedback... 3 Overview... 3 Downloading and installation...3 Pre-processing
More informationHanwell Instruments Ltd. Instruction Manual
Hanwell Instruments Ltd Instruction Manual Document Title RL5000 Sensors - User Guide Document No. IM4177 Issue No. 3 Hanwell Instruments Ltd 12 Mead Business Centre Mead Lane Hertford SG13 7BJ UNITED
More informationA Hierarchical Artificial Neural Network Model for Giemsa-Stained Human Chromosome Classification
A Hierarchical Artificial Neural Network Model for Giemsa-Stained Human Chromosome Classification JONGMAN CHO 1 1 Department of Biomedical Engineering, Inje University, Gimhae, 621-749, KOREA minerva@ieeeorg
More informationDETECTION OF HEART ABNORMALITIES USING LABVIEW
IASET: International Journal of Electronics and Communication Engineering (IJECE) ISSN (P): 2278-9901; ISSN (E): 2278-991X Vol. 5, Issue 4, Jun Jul 2016; 15-22 IASET DETECTION OF HEART ABNORMALITIES USING
More informationfor Heart-Health Scanning
Magnetocardiography for Heart-Health Scanning CardioMag Imaging, Inc. 1 Basic Principles of Magnetocardiography (MCG) The cardiac electric activity that produces a voltage difference on the body surface
More informationBiopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev
42 Aero Camino, Goleta, CA 93117 www.biopac.com Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure Rev. 12292017 Richard Pflanzer, Ph.D. Associate Professor Emeritus Indiana University
More informationVarious Methods To Detect Respiration Rate From ECG Using LabVIEW
Various Methods To Detect Respiration Rate From ECG Using LabVIEW 1 Poorti M. Vyas, 2 Dr. M. S. Panse 1 Student, M.Tech. Electronics 2.Professor Department of Electrical Engineering, Veermata Jijabai Technological
More informationMODULE: SQUAT JUMP BRIEF DESCRIPTION:
MODULE: SQUAT JUMP BRIEF DESCRIPTION: Squat jump is a vertical jump and among the most often used tests for maximal anaerobic power output of the lower extremities. It is a concentric muscle action which
More informationWhat you re in for. Who are cochlear implants for? The bottom line. Speech processing schemes for
What you re in for Speech processing schemes for cochlear implants Stuart Rosen Professor of Speech and Hearing Science Speech, Hearing and Phonetic Sciences Division of Psychology & Language Sciences
More informationDigital. hearing instruments have burst on the
Testing Digital and Analog Hearing Instruments: Processing Time Delays and Phase Measurements A look at potential side effects and ways of measuring them by George J. Frye Digital. hearing instruments
More informationA NOVEL ALGORITHM TO PREDICT KNEE ANGLE FROM EMG SIGNALS FOR CONTROLLING A LOWER LIMB EXOSKELETON
A NOVEL ALGORITHM TO PREDICT KNEE ANGLE FROM EMG SIGNALS FOR CONTROLLING A LOWER LIMB EXOSKELETON Inderjeet Singh Dhindsa 1, Ravinder Agarwal 1, Hardeep Singh Ryait 2 1 EIED, Thapar University Patiala,
More informationEEG, ECG Measurement and Data Analysis. Carlo Lucignoli. ATSiP Teesside 2006
EEG, ECG Measurement and Data Analysis Carlo Lucignoli ATSiP Teesside 2006 What are we trying to achieve? The psychologists wish to measure patients anxiety. The measurement is shown to patients so they
More informationDoctoral School on Engineering Sciences Università Politecnica delle Marche
Doctoral School on Engineering Sciences Università Politecnica delle Marche Extended summary Muscle Fatigue Assessment during Flexion Extension Movements Curriculum: Electromagnetism and Bioengineering
More informationSedLine Sedation Monitor
SedLine Sedation Monitor Quick Reference Guide Not intended to replace the Operator s Manual. See the SedLine Sedation Monitor Operator s Manual for complete instructions, including warnings, indications
More informationEMG Signals for Co-Activations of Major Lower Limb Muscles in Knee Joint Dynamics
Biomedical Science and Engineering, 2015, Vol. 3, No. 1, 9-14 Available online at http://pubs.sciepub.com/bse/3/1/3 Science and Education Publishing DOI:10.12691/bse-3-1-3 EMG Signals for Co-Activations
More informationDigital hearing aids are still
Testing Digital Hearing Instruments: The Basics Tips and advice for testing and fitting DSP hearing instruments Unfortunately, the conception that DSP instruments cannot be properly tested has been projected
More informationSTATISTICS AND RESEARCH DESIGN
Statistics 1 STATISTICS AND RESEARCH DESIGN These are subjects that are frequently confused. Both subjects often evoke student anxiety and avoidance. To further complicate matters, both areas appear have
More information