First (preliminary) results from BTF measurements in the LHC

Size: px
Start display at page:

Download "First (preliminary) results from BTF measurements in the LHC"

Transcription

1 First (preliminary) results from BTF measurements in the LHC C. Tambasco X. Buffat, T. Pieloni, J. Barranco Acknowledgements: G. Trad, A. Boccardi, M. Gasior, T. Levens, T. Lefevre, M.Khun W. Hofle, E. Metral, D. Valuch, G. Kotzian. OP: M. Pojer, R. Giachino, B. Salvachia,M. Solfaroli, J. Wenninger and all the crews on shift (Kajtan, Markus, Giulia, Lasse, Reyes) And all the other MD users for spare time

2 BTF measurements have been performed for the first time in LHC The BTF system has been developed by the BI team BTF system has been set-up (no MD time was allocated) to be transparent to the beams (no emittance neither losses observed) Several configurations have been tested and will be presented Experimental data - simulations comparisons will be discussed (preliminary) Next step: SD computation (PySSD) from SixTrack particle distribution Summary

3 What are BTF measurements? Beam Transfer Function: beam amplitude response per driving excitation frequency ADT kicker beam BBQ pickup Ain, φin, Ω Network Analyzer Beam Response Aout, φout, Ω BTF: Amplitude (Ω), phase (Ω )

4 BTF measurements btf_gui.py

5 BTF measurements Plane

6 BTF measurements Plane Excitation amplitude

7 BTF measurements Plane Excitation amplitude Frequency range

8 BTF measurements Plane Excitation amplitude Frequency range Frequency step

9 Why BTF measurements? Particle distribution BTF= Frequency Distribution ( Landau Damping with two dimensional betatron tune spread, J. S. Berg and F. Ruggero) Tunes and coherent mode observations Spread measurements etc Direct measurements of the Landau Stability Diagrams Sensitive to particle distribution changes BTF measurement is the only way to test the model of the Stability diagrams

10 Summary of the BTF measurements BTF measurements tested on pilot and nominal bunches at injection and at flat top Excitation amplitude scan: good settings have been found to be transparent Octupole scan (at injection and flat top) Beams in collision (at injection and after the squeeze) ADT gain scan (at flat top) Chromaticity scan (at flat top) LR contribution (end of the squeeze, LR separation ~14σ )

11 Amplitude scan: safe BTF configuration BSRT data, injection, pilot bunches The excitation amplitude is not calibrated (restricted time for BTF setup) BTF excitations use about 0.01 % of the damper power

12 Synchrotron sidebands in BTF response Synchrotron sidebands visible in the BTF signal expected at ±0.005 at injection from the peak of the tune Q ~7 units Phase jump clearly visible in correspondence of the synchrotron sidebands and coherent tune

13 ADT effect on BTF amplitude response ADT effect on the BTF Sidebands still visible, very high, Q ~7 We corrected chromaticity and switched off the ADT (here already collision tunes) Q ~2 Q=±0.005

14 MD : Octupole scan injection

15 MD : Octupole scan injection Losses for 26 A octupole current

16 Octupole scan at Injection: BTF amplitude response Octupole scan at injection with pilot bunches at collision tunes Q ~2 εnorm=2 μm [a.u.] [a.u.] Each BTF signal has been normalized at the maximum value

17 Octupole scan at Injection: BTF phase Phase Phase The slope of the phase increase while increasing the spread Bad phase in vertical, could not be used to reproduce SD in vertical

18 Octupole scan at Injection: Footprint Q ~2 εnorm=2 μm

19 Octupole scan at Injection: Footprint Q ~2 εnorm=2 μm

20 Octupole scan at Injection: Footprint Q ~2 εnorm=2 μm

21 Octupole scan at Injection: Footprint Q ~2 εnorm=2 μm Vertical losses observed (D. Mirarchi)

22 BTF simulation with COMBI A sinusoidal excitation is applied to the beam: Positive LOF 6.5 A Horizontal/Vertical plane excitation amplitude Initial excitation frequency Final excitation frequency Resolution of the frequency step Number of turns for each step of the BTF excitation The tune spread is computed with MAD-X and given as an input in COMBI (linear spread)

23 Some first observations and preliminary results Preliminary results B1 H At 0 octupole current, the spread is not the one expected from simulations

24 Some first observations and preliminary results Preliminary results B1 H The spread at 0 A is reproduced with ~5 A octupole current This is consistent with measured spread at injection equivalent to 3 A (R. Tomas, further checks needed)

25 Some first observations and preliminary results Preliminary results B1 H

26 Some first observations and preliminary results Preliminary results B1 H 10 A octupole current is needed to reproduce 6.5 A BTF measurements

27 Some first observations and preliminary results Preliminary results B1 H

28 Some first observations and preliminary results Preliminary results B1 H Very noise signal for COMBI simulation, still needed to be understood, but some of the visible peaks are also present in measurements

29 Preliminary results B1 V

30 Some first observations and preliminary results Preliminary results B1 V

31 Some first observations and preliminary results Preliminary results B1 V

32 Some first observations and preliminary results Preliminary results B1 V

33 Some first observations and preliminary results Preliminary results B1 V

34 Some first observations and preliminary results Preliminary results B1 V Measured spread smaller than the one expected

35 Some first observations and preliminary results Preliminary results B1 V Measured spread smaller than the one expected

36 Beam in collision at injection BTF signal when beams in collisions in IP1&5: pi and sigma-mode visible Optimization of the IPs was performed looking at the shift from the BTF Blow up observed during BTF possibly due to the excitation of the pi mode (ADT off) π mode V Measured tune shift by BTF ΔQ~ (expected ΔQ=0.013) π mode H

37 Beam in collision at flat top Looking at the π-mode position we can optimize collisions Incoherent spread visible between σ-mode and π-mode No emittance blow up observed (ADT Off) Measured tune shift by BTF ΔQ~ (expected ΔQ=0.008)

38 ADT gain scan at Flat top High chromaticity > very high sidebands Q ~15 units The coherent tune is visible for an ADT gain of 100 turns (knob of 0.02)

39 Chromaticity scan at Flat top Chroma 15 units gives large response, higher than the coherent tune amplitude Sidebands go down decreasing the chromaticity, and the amplitude of the coherent tune increases

40 Chromaticity scan at Flat top Data normalized to the amplitude of the coherent tune to compare measurements

41 Chromaticity scan at Flat top Data normalized to the amplitude of the coherent tune to compare measurements

42 Chromaticity scan: sidebands ratio Sideband ratio: A= S1/S0 > Independent from excitation amplitude Quadratic behavior of the amplitude ratio of the sidebands To be verified and further investigated vs analytical expectations (S. Fartoukh LHC LHC Project Report 986 )

43 Chromaticity scan: tune shift from sextupoles High sensitivity in tune measurements with BTF amplitude response > Feed-down effect from sextupoles on the tune while changing chromaticity

44 Octupole scan at Flat top: BTF amplitude response εnorm=2.4 μm εnorm=2.2 μm Data normalized to the BTF amplitude of the coherent tune Less impact on the BTF amplitude width while changing octupole current

45 Octupole scan at Flat top: BTF phase

46 Octupole scan at Flat top: BTF phase

47 Octupole scan at Flat top: BTF phase

48 Octupole scan at Flat top: BTF phase The resolution in the phase is not good to reproduce SD

49 Octupole scan at Flat top VS PySSD simulations PySSD and BTF data comparison B1 H B1 V

50 Octupole scan at Flat top VS PySSD simulations B1 H B1 V

51 Octupole scan at Flat top VS PySSD simulations B1 H B1 V

52 Octupole scan at Flat top VS PySSD simulations B1 H B1 V

53 BTF measurements end of the squeeze εnorm=2.24 μm εnorm=2.19 μm Beam-beam LR at ~14σ : really small contribution as expected with a such separation However there is an asymmetry w.r.t. the vertical plane

54 PySSD and BTF measurements comparison B1 H B1 V

55 PySSD and BTF measurements comparison B1 H B1 V

56 PySSD and BTF measurements comparison B1 H B1 V Simulations predict a small increase in the spread, not observed in the vertical plane

57 Crossing angle asymmetry Emittance difference in the planes of 2.3%, can this explain the different behavior? Can this be related with uncertainty on crossing angle? Update on crossing angles in IR1 and IR5 J. Wenninger (LBOC meeting 27/10/2015)

58 Crossing angle asymmetry Emittance difference in the planes of 2.3%, can this explain the different behavior? Can this be related with uncertainty on crossing angle? Update on crossing angles in IR1 and IR5 J. Wenninger (LBOC meeting 27/10/2015)

59 Measured Stability Diagram at Injection 11.5 A octupole current ε=2.0 μm

60 Next step: integrate the distribution from SixTrack to compute SD with PySSD We needed to smooth the SixTrack distribution in order to integrate the dispersion integral A bilinear interpolation (2D) has been used to smooth the histogram of the distribution Known case, analytical linear detuning from octupoles only (-100 A) Initial uniform distribution at the 1st turn in SixTrack Jy Jx

61 SixTrack distribution Known case, analytical linear detuning from octupoles only (-100 A) Weighted distribution for gaussian shape exp(jx,jy) 100 bins Interpolated Jy Jx

62 SixTrack distribution Known case, analytical linear detuning from octupoles only (-100 A) Distribution after 1e6 turns in SixTrack 100 bins Jy Jy Jx Jx

63 Stability Diagram from SixTrack distribution Known case, analytical linear detuning from octupoles only -100 A, 4 TeV, ε=2.2 μm The integration is working, we can reproduce the SD from PySSD integrating the SixTrack distribution

64 Stability Diagram from SixTrack distribution Known case, analytical linear detuning from octupoles only -100 A, 4 TeV, ε=2.2 μm

65 Technical summary for LHC 2016 start up BTF measurement have been set-up to be completely transparent on the beams (while separated) BTF system has been tested on several machine configuration (on pilot and nominal bunches, at injection and flat top, with different ADT gains and chroma, on colliding and non colliding beams) Outlook for the 2016: LHC 2016 > Setup of the system to be transparent to the beam (start up stage) Need calibration of the excitation amplitude with the BI team collaboration More flexible BTF GUI B2 Vertical plane signal to be investigated

66 BTF Summary Extra spread at injection with 0 A octupole current, probably due to non linearities (reproducible by simulations with 5 A octupole current) Consistent with optics measurements at injection (further checks with R. Tomas ref: Collecting amplitude detuning measurements from 2012 R. Tomas et all) From BTF measurements we can measure the tune and coherent modes with a resolution of 10^-4 ADT gain scan: coherent modes visible for an ADT gain of 100 turns Chromaticity scan: the ratio of the heights of the tune peak and sidebands have a parabolic behavior, we can measure the feed-down effects due to sextupoles with a sensitivity of 10^-4 Octupole scan at flat top: not large impact on spread with different octupole, good agreement with simulations (better in vertical plane) End of the squeeze: observed asymmetry between H and V possible explanations: different emittance, crossing angle, multipolar errors at triplets?

67 Ongoing & Outlook Confirm with simulations spread of non linearities at injection and understand how it adds-up to the spread for higher octupole currents Further simulations required to explain the measured spread after the squeeze: combine uncertainty on the x-angle and smaller emittance in V Further investigation on analytical expectations for chromaticity scan (S. Fartoukh LHC Project Report 986 ) Integrate SixTrack distribution in PySSD, problem on the histogram binning to be solved (convergence problem)

68 Stability Diagram from SixTrack distribution Known case, analytical linear detuning from octupoles only -100 A, 4 TeV, ε=2.2 μm There is a dependency on the chosen binning to create the distribution histogram from SixTrack Convergence needs to be found

69 Measured Stability Diagram at Injection 6.5 A octupole current ε=3.75 μm

MD Landau Damping: Beam Transfer Functions and diffusion mechanisms

MD Landau Damping: Beam Transfer Functions and diffusion mechanisms CERN-ACC-NOTE-2017-0027 25-04-2017 claudia.tambasco@cern.ch MD 1856 - Landau Damping: Beam Transfer Functions and diffusion mechanisms C. Tambasco, J. Barranco *, A. Boccardi, X. Buffat, M. Crouch, M.

More information

Crystal Collimation Cleaning Measurements with Proton Beams in LHC

Crystal Collimation Cleaning Measurements with Proton Beams in LHC CERN-ACC-Note-2018-0024-MD 2016.07.29 Roberto.Rossi@cern.ch Crystal Collimation Cleaning Measurements with Proton Beams in LHC R. Rossi, O. Aberle, O. O. Andreassen, M. Butcher, C. A. Dionisio Barreto,

More information

Halo Collimation Depth Using BDSIM

Halo Collimation Depth Using BDSIM Halo Collimation Depth Using BDSIM John Carter Royal Holloway University of London Halo Collimation Depth Studies Full BDS Collimation plans Example of BDSIM collimation capabilities Conclusion John.Carter@.rhul

More information

Modified Collimation Layout & Optics (for cryogenic collimators in IR3 with maximum 4.5 m displacement of elements )

Modified Collimation Layout & Optics (for cryogenic collimators in IR3 with maximum 4.5 m displacement of elements ) Modified Collimation Layout & Optics (for cryogenic collimators in IR3 with maximum 4.5 m displacement of elements ) J.M. Jowett, Collimation Working Group, 19/7/2010 1 IR3 Optics overview, Beam 1 Primary

More information

Re-circulating Linac Option

Re-circulating Linac Option FLS 2010, ICFA Beam Dynamics Workshop, SLAC, 1-5 th March 10 Re-circulating Linac Option Deepa Angal-Kalinin, Peter Williams & D. Dunning ASTeC, STFC, Daresbury Laboratory & The Cockcroft Institute Contents

More information

Double Stage Seeded FEL With Fresh Bunch Injection Technique at FERMI

Double Stage Seeded FEL With Fresh Bunch Injection Technique at FERMI Double Stage Seeded FEL With Fresh Bunch Injection Technique at FERMI Enrico Allaria on behalf of the FERMI commissioning team 1 Outline Seeded Free Electron Lasers Benefits and possibilities Seeded FEL

More information

RESULTS OF THE LHC DCCT CALIBRATION STUDIES

RESULTS OF THE LHC DCCT CALIBRATION STUDIES CERN-ATS-Note-212-26 PERF BI DCCT Note RESULTS OF THE LHC DCCT CALIBRATION STUDIES C. Barschel 1,2, M. Ferro-Luzzi 1, J.J. Gras 1, M. Ludwig 1, P. Odier 1, and S. Thoulet 1 1 CERN, Geneva, Switzerland

More information

LHC Collimation Status and Plans

LHC Collimation Status and Plans 2 nd Joint HiLumi LHC-LARP Annual Meeting INFN, Laboratori Nazionali di Frascati Frascati, Italy, November 14 th -16 th, 2012 LHC Collimation Status and Plans Stefano Redaelli, CERN, BE-ABP on behalf of

More information

Outline Fermi experimental setup Impact of the laser heater on seeded FEL Non-Gaussian effects 2

Outline Fermi experimental setup Impact of the laser heater on seeded FEL Non-Gaussian effects 2 Benefits of the laser heater induced energy spread for high harmonic conversion in HGHG FEL E. Ferrari 1,2, G. Penco 1, E. Allaria 1, S. Spampinati 1, L. Giannessi 1,3, W. Fawley 1, Z. Huang 4 1. Elettra

More information

Collimation Experience at the Large Hadron Collider

Collimation Experience at the Large Hadron Collider 52 nd ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams, HB2012 Beijing, China, September 17 th -21 th, 2012 Collimation Experience at the Large Hadron Collider Stefano

More information

CONCEPTUAL SPECIFICATION TECG FOR CRYSTAL COLLIMATION AT THE LHC WP5

CONCEPTUAL SPECIFICATION TECG FOR CRYSTAL COLLIMATION AT THE LHC WP5 EDMS NO. 1366524 REV. 0.2 VALIDITY DRAFT REFERENCE : LHC- TECG- ES- 0001 CONCEPTUAL SPECIFICATION TECG FOR CRYSTAL COLLIMATION AT THE LHC WP5 Equipment/system description Crystal collimation of hadron

More information

E. Allaria. on behalf of the FERMI team

E. Allaria. on behalf of the FERMI team E. Allaria on behalf of the FERMI team Work partially supported by the Italian Ministry of University and Research under grants FIRB-RBAP045JF2 and FIRB-RBAP06AWK3 1 2 Outline Elettra and the FERMI FEL

More information

X ray Spectra and Peak Power Control with isase. J. Wu (SLAC) and C. Pellegrini (UCLA/SLAC) May 15, 2013

X ray Spectra and Peak Power Control with isase. J. Wu (SLAC) and C. Pellegrini (UCLA/SLAC) May 15, 2013 X ray Spectra and Peak Power Control with isase J. Wu (SLAC) and C. Pellegrini (UCLA/SLAC) May 15, 2013 OUTLINE Review SASE FEL Short longitudinal coherent length leads to spiky temporal and spectral profiles

More information

First Demonstration of High Gain Lasing and Polarization Switch with a Distributed Optical Klystron FEL at Duke University

First Demonstration of High Gain Lasing and Polarization Switch with a Distributed Optical Klystron FEL at Duke University First Demonstration of High Gain Lasing and Polarization Switch with a Distributed Optical Klystron FEL at Duke University *, N. A. Vinokurov# S. Mikhailov*, J. Li*, V. Popov* *FEL Lab, Department of Physics,

More information

w. D. Jolly, F. A. Bruton, and C. Fedor

w. D. Jolly, F. A. Bruton, and C. Fedor ULTRASONIC TRANSDUCER CHARACTERIZATION STATION w. D. Jolly, F. A. Bruton, and C. Fedor Southwest Research Institute 6220 Culebra Road San Antonio, Texas 78284 INTRODUCTION The portable ultrasonic transducer

More information

DPA calculations with FLUKA

DPA calculations with FLUKA DPA calculations with FLUKA A. Lechner, L. Esposito, P. Garcia Ortega, F. Cerutti, A. Ferrari, E. Skordis on behalf of the FLUKA team (CERN) with valuable input from R. Bruce, P.D. Hermes, S. Redaelli

More information

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Performance of phased array and conventional ultrasonic probes on the new ISO reference block Performance of phased array and conventional ultrasonic probes on the new ISO 19675 reference block C. Udell, D. Chai 1 and F. Gattiker Proceq S.A., Ringstrasse 2, Schwerzenbach, Switzerland. More info

More information

NDT PERFORMANCE DEMONSTRATION USING SIMULATION

NDT PERFORMANCE DEMONSTRATION USING SIMULATION NDT PERFORMANCE DEMONSTRATION USING SIMULATION N. Dominguez, F. Jenson, CEA P. Dubois, F. Foucher, EXTENDE nicolas.dominguez@cea.fr CEA 10 AVRIL 2012 PAGE 1 NDT PERFORMANCE DEMO. USING SIMULATION OVERVIEW

More information

Task Test beam infrastructure in Frascati LNF, Ferrara & Perugia INFN structure and University of Bergen

Task Test beam infrastructure in Frascati LNF, Ferrara & Perugia INFN structure and University of Bergen Task 8.2.2 Test beam infrastructure in Frascati LNF, Ferrara & Perugia INFN structure and University of Bergen 1 DAFNE accelerator Complex The BTF (Beam Test Facility) is part of the DAFNE accelerator

More information

FERMI: EUV and Soft X-Ray FELs with HGHG

FERMI: EUV and Soft X-Ray FELs with HGHG 1 FERMI: EUV and Soft X-Ray FELs with HGHG E. Allaria on behalf of the FERMI commissioning team Enrico Allaria Outline 2 Elettra and the FERMI FEL project FERMI parameters FEL-1 experimental results FEL

More information

CREX Magnet Considerations

CREX Magnet Considerations CREX Magnet Considerations Seamus Riordan University of Massachusetts, Amherst sriordan@physics.umass.edu April 12, 2014 Seamus Riordan CREX Magnet 1/12 Optimize Kinematics Compete against falling rates

More information

CONCEPTUAL SPECIFICATION TARGET COLLIMATOR LONG DISPERSION SUPPRESSOR P7 [TCLD]

CONCEPTUAL SPECIFICATION TARGET COLLIMATOR LONG DISPERSION SUPPRESSOR P7 [TCLD] REV. 0.2 VALIDITY DRAFT REFERENCE : LHC- TCLD- ES- 0002 EDMS NO. 1366519 CONCEPTUAL SPECIFICATION TARGET COLLIMATOR LONG DISPERSION SUPPRESSOR P7 [TCLD] Equipment/system description Dispersion suppressor

More information

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Jason Silver August 26, 2009 Presentation Outline Introduction Thesis Objectives Mathematical Model and Principles Methods

More information

RVTEC 2010 UHDAS/ADCP

RVTEC 2010 UHDAS/ADCP RVTEC 2010 UHDAS/ADCP Part I: ADCP Getting Ocean Velocity What can go wrong ADCP Processing with CODAS Part II: UHDAS 1: Outline What it does Where things are written Monitoring, Interpretation What can

More information

7 Grip aperture and target shape

7 Grip aperture and target shape 7 Grip aperture and target shape Based on: Verheij R, Brenner E, Smeets JBJ. The influence of target object shape on maximum grip aperture in human grasping movements. Exp Brain Res, In revision 103 Introduction

More information

bio-mof-1 DMASM Wavenumber (cm -1 ) Supplementary Figure S1 FTIR spectra of bio-mof-1, DMASMI, and bio-mof-1 DMASM.

bio-mof-1 DMASM Wavenumber (cm -1 ) Supplementary Figure S1 FTIR spectra of bio-mof-1, DMASMI, and bio-mof-1 DMASM. bio-mof-1 Transmittance bio-mof-1 DMASM DMASMI 2000 1500 1000 500 Wavenumber (cm -1 ) Supplementary Figure S1 FTIR spectra of bio-mof-1, DMASMI, and bio-mof-1 DMASM. Intensity (a.u.) bio-mof-1 DMASM as

More information

A new geometric and mechanical verification device for medical LINACs

A new geometric and mechanical verification device for medical LINACs JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 A new geometric and mechanical verification device for medical LINACs Keith T. Welsh,* Robert A. Wlodarczyk, and L. E. Reinstein

More information

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

A new method of sonograph lateral resolution measurement using PSF analysis of received signal A new method of sonograph lateral resolution measurement using PSF analysis of received signal L. Doležal, J. Hálek Faculty of Medicine Palacký University in Olomouc, Czech Republic E-mail: ladol@tunw.upol.cz

More information

Feng Xiujuan National Institute of Metrology (NIM),China

Feng Xiujuan National Institute of Metrology (NIM),China The acoustic calibration service in transportation at NIM Feng Xiujuan National Institute of Metrology (NIM),China 1. Calibration requirements 2. Calibration service at NIM 2.1 Microphone 2.2 Ultrasonic

More information

The Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation. Presented at EPAC 2008, Genova D. Ondreka, GSI

The Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation. Presented at EPAC 2008, Genova D. Ondreka, GSI The Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation Presented at EPAC 2008, Genova D. Ondreka, GSI Introduction Heidelberg Ion Therapy Centre: Europe's first dedicated particle therapy facility

More information

Last report Nov 12, measured PMT #1; discussed new faceplate for setup; beam profile studies that suggest beam spot with σ 60

Last report Nov 12, measured PMT #1; discussed new faceplate for setup; beam profile studies that suggest beam spot with σ 60 PMT SCANNINGS SETUP ETUP PROGRESS Last report Nov 12, 2002. measured PMT #1; discussed new faceplate for setup; beam profile studies that suggest beam spot with σ 60 60-90µm What s s new? scans of second

More information

Possibilities of time resolved studies at FLASH

Possibilities of time resolved studies at FLASH Possibilities of time resolved studies at FLASH S. Düsterer Outline Pump-probe at FLASH FEL + FEL Optical lasers + FEL THz + FEL The future FEL + FEL split and delay Autocorrelator / beam splitter Uni

More information

SpiderX. Portable Residual Stress X-Ray Diffractometer.

SpiderX. Portable Residual Stress X-Ray Diffractometer. Portable Residual Stress X-Ray Diffractometer www.gnr.it About SpiderX GNR Analytical Instrument offers equipment based on X-Ray Diffraction to measure residual stress state and retained austenite content.

More information

NAILFOLD CAPILLAROSCOPY USING USB DIGITAL MICROSCOPE IN THE ASSESSMENT OF MICROCIRCULATION IN DIABETES MELLITUS

NAILFOLD CAPILLAROSCOPY USING USB DIGITAL MICROSCOPE IN THE ASSESSMENT OF MICROCIRCULATION IN DIABETES MELLITUS NAILFOLD CAPILLAROSCOPY USING USB DIGITAL MICROSCOPE IN THE ASSESSMENT OF MICROCIRCULATION IN DIABETES MELLITUS PROJECT REFERENCE NO. : 37S0841 COLLEGE BRANCH GUIDE : DR.AMBEDKAR INSTITUTE OF TECHNOLOGY,

More information

Neuron, Volume 63 Spatial attention decorrelates intrinsic activity fluctuations in Macaque area V4.

Neuron, Volume 63 Spatial attention decorrelates intrinsic activity fluctuations in Macaque area V4. Neuron, Volume 63 Spatial attention decorrelates intrinsic activity fluctuations in Macaque area V4. Jude F. Mitchell, Kristy A. Sundberg, and John H. Reynolds Systems Neurobiology Lab, The Salk Institute,

More information

Ch.20 Dynamic Cue Combination in Distributional Population Code Networks. Ka Yeon Kim Biopsychology

Ch.20 Dynamic Cue Combination in Distributional Population Code Networks. Ka Yeon Kim Biopsychology Ch.20 Dynamic Cue Combination in Distributional Population Code Networks Ka Yeon Kim Biopsychology Applying the coding scheme to dynamic cue combination (Experiment, Kording&Wolpert,2004) Dynamic sensorymotor

More information

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance Jan Gajewski Institute of Nuclear Physics, Kraków, Poland German Cancer Research Center, Heidelberg, Germany Existing

More information

Routine Quality Assurance Cookbook

Routine Quality Assurance Cookbook This Cookbook is a companion guide to the AIUM Routine Quality Assurance (QA) for Diagnostic Ultrasound Equipment document, which outlines the basic QA requirements for AIUM-accredited practices. The Guide

More information

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of

More information

Beam Loss and Collimation in the ESS Linac

Beam Loss and Collimation in the ESS Linac Beam Loss and Collimation in the ESS Linac Ryoichi Miyamoto (ESS) B. Cheymol, H. Danared, M. Eshraqi, A. Ponton, J. Stovall, L. Tchelidze (ESS) I. Bustinduy (ESS-Bilbao) H. D. Thomsen, A. I. S. Holm, S.

More information

A Comparison of Interaction Physics for Proton Collimation Systems in Current Simulation Tools

A Comparison of Interaction Physics for Proton Collimation Systems in Current Simulation Tools A Comparison of Interaction Physics for Proton Collimation Systems in Current Simulation Tools J. Molson et al. Laboratoire de l Accélérateur Linéaire May 17, 2017 J. Molson et al. Proton collimation simulation

More information

Peak Analysis using Cumulative Peak Fitting:

Peak Analysis using Cumulative Peak Fitting: Peak Analysis using Cumulative Peak Fitting: An Approach to get more Information from a C TOF AMS Spectrum Markus Müller 1, Thorsten Titzmann 2, Christian George 1, Barbara D Anna 1 [1] IRCELYON, CNRS,

More information

ACCELERATOR DESIGN ISSUES IN CANCER THERAPY

ACCELERATOR DESIGN ISSUES IN CANCER THERAPY ACCELERATOR DESIGN ISSUES IN CANCER THERAPY December 25 P.J. Bryant CERN John ADAMS Memorial Lecture 25- P.J. Bryant - Slide 1 Contents Introduction Hadrons & voxel scanning Experimental setup A closer

More information

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods

More information

Theta sequences are essential for internally generated hippocampal firing fields.

Theta sequences are essential for internally generated hippocampal firing fields. Theta sequences are essential for internally generated hippocampal firing fields. Yingxue Wang, Sandro Romani, Brian Lustig, Anthony Leonardo, Eva Pastalkova Supplementary Materials Supplementary Modeling

More information

Linear Ultrasonic Wave Propagation in Biological Tissues

Linear Ultrasonic Wave Propagation in Biological Tissues Indian Journal of Biomechanics: Special Issue (NCBM 7-8 March 29) Linear Ultrasonic Wave Propagation in Biological Tissues Narendra D Londhe R. S. Anand 2, 2 Electrical Engineering Department, IIT Roorkee,

More information

Shcherbakov O.N., Petrov A.E., Polevoy A.G., Annenkov A.S. ULTES LLC, Moscow, Russia

Shcherbakov O.N., Petrov A.E., Polevoy A.G., Annenkov A.S. ULTES LLC, Moscow, Russia METHODS AND MEANS OF ULTRASONIC INSPECTION (USI) OF WELDED JOINTS WITH ACOUSTIC CONTACT LEVEL TRACKING AND EVALUATION OF THE NATURE AND ACTUAL CHARACTERISTICS OF FLAWS Shcherbakov O.N., Petrov A.E., Polevoy

More information

The LHC Collimation System

The LHC Collimation System The LHC Collimation System Ralph W. Aßmann for the LHC Collimation Project AB Seminar 10.03.2005 1/54 Based on the results of the work by: O. Aberle,,,, I. Baishev,, A. Bertarelli,, H. Braun, M. Brugger,,

More information

Biological Optimization of Hadrontherapy. Uwe Oelfke

Biological Optimization of Hadrontherapy. Uwe Oelfke 4/2/2012 page 1 Biological Optimization of Hadrontherapy Uwe Oelfke DKFZ Heidelberg (E040) Im Neuenheimer Feld 280 69120 Heidelberg, Germany u.oelfke@dkfz.de 4/2/2012 page 2 Contents Introduction and General

More information

Acceptance testing of a large aperture dynamic wavefront sensor

Acceptance testing of a large aperture dynamic wavefront sensor Acceptance testing of a large aperture dynamic wavefront sensor David J. Fischer*, Alan Wertheimer, Laurie Hill Eastman Kodak Company, 1447 St. Paul St, Rochester, NY 14653 ABSTRACT A large aperture dynamic

More information

Bruker D8 Discover User Manual (Version: July 2017)

Bruker D8 Discover User Manual (Version: July 2017) University of Minnesota College of Science and Engineering Characterization Facility Eulerian cradle Reference 2θ (two-theta): Detector angle (GADDS angle # 1) Bruker D8 Discover User Manual (Version:

More information

Luminosity Monitor and Test Run Results. Presented by: Luis Mercado UMASS Amherst 7/23/08

Luminosity Monitor and Test Run Results. Presented by: Luis Mercado UMASS Amherst 7/23/08 Luminosity Monitor and Test Run Results Presented by: Luis Mercado UMASS Amherst 7/23/08 Overview Luminosity Monitors Lumi Setup Components PMT Linearity Motivation/Formalism Experimental Test Setup Acceptable

More information

Supplementary Figure 1. Sample preparation schematic. First (Stage I), square islands of MoO 3 are prepared by either photolithography followed by

Supplementary Figure 1. Sample preparation schematic. First (Stage I), square islands of MoO 3 are prepared by either photolithography followed by Supplementary Figure 1. Sample preparation schematic. First (Stage I), square islands of MoO 3 are prepared by either photolithography followed by thermal evaporation and liftoff or by a process where

More information

Digital film dosimetry in radiotherapy and the development of analytical applications software

Digital film dosimetry in radiotherapy and the development of analytical applications software University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2005 Digital film dosimetry in radiotherapy and the development

More information

Manual Ultrasonic Inspection of Thin Metal Welds

Manual Ultrasonic Inspection of Thin Metal Welds 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Manual Ultrasonic Inspection of Thin Metal Welds More Info at Open Access Database www.ndt.net/?id=16364

More information

Biologically-Inspired Human Motion Detection

Biologically-Inspired Human Motion Detection Biologically-Inspired Human Motion Detection Vijay Laxmi, J. N. Carter and R. I. Damper Image, Speech and Intelligent Systems (ISIS) Research Group Department of Electronics and Computer Science University

More information

EFFECTS OF SPATIAL VARIATION OF SEISMIC INPUTS ON BRIDGE LONGITUDINAL RESPONSE

EFFECTS OF SPATIAL VARIATION OF SEISMIC INPUTS ON BRIDGE LONGITUDINAL RESPONSE 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 64 EFFECTS OF SPATIAL VARIATION OF SEISMIC INPUTS ON BRIDGE LONGITUDINAL RESPONSE Jiachen WANG 1, Athol

More information

Terahertz reflectometry imaging for low and high grade gliomas

Terahertz reflectometry imaging for low and high grade gliomas Terahertz reflectometry imaging for low and high grade gliomas Young Bin Ji 1,9, Seung Jae Oh 1,9, Seok-Gu Kang 2,9, Jung Heo 3,9, Sang-Hoon Kim 1,4, Yuna Choi 1, Seungri Song 3, Hye Young Son 5, Se Hoon

More information

Genetic Algorithms and their Application to Continuum Generation

Genetic Algorithms and their Application to Continuum Generation Genetic Algorithms and their Application to Continuum Generation Tracy Moore, Douglass Schumacher The Ohio State University, REU, 2001 Abstract A genetic algorithm was written to aid in shaping pulses

More information

Some Thoughts on Calibrating LaModel

Some Thoughts on Calibrating LaModel Some Thoughts on Calibrating LaModel Dr. Keith A. Heasley Professor Department of Mining Engineering West Virginia University Introduction Recent mine collapses and pillar failures have highlighted hli

More information

The DAΦNE Beam Test Facility & AGILE Calibration

The DAΦNE Beam Test Facility & AGILE Calibration The DAΦNE Beam Test Facility & AGILE Calibration BTF webcam live view B. Buonomo, G. Mazzitelli, L. Quintieri INFN LNF, P. Valente INFN Roma 1 The DAΦNE BTF BTF The BTF is a e /e + test-beam facility in

More information

CHIRPED PULSE AMPLIFICATION FOR SHORT VUV FEL PULSES AT

CHIRPED PULSE AMPLIFICATION FOR SHORT VUV FEL PULSES AT CHIRPED PULSE AMPLIFICATION FOR SHORT VUV FEL PULSES AT FERMI@ELETTRA David Garzella (CEA/IRAMIS/LIDYL) and G. De Ninno (Univ. of Nova Gorica/Sincrotrone Trieste) (On behalf of the FERMI CPA Collaboration)

More information

Verification of micro-beam irradiation

Verification of micro-beam irradiation Journal of Physics: Conference Series OPEN ACCESS Verification of micro-beam irradiation To cite this article: Qiongge Li et al 2015 J. Phys.: Conf. Ser. 573 012047 View the article online for updates

More information

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV M. Mumot, G. V. Mytsin, Y. I. Luchin and A. G. Molokanov Medico-Technical

More information

Atmospheric Correction: candidate improvements Erwin Wolters, Sindy Sterckx, and Stefan Adriaensen

Atmospheric Correction: candidate improvements Erwin Wolters, Sindy Sterckx, and Stefan Adriaensen Atmospheric Correction: candidate improvements Erwin Wolters, Sindy Sterckx, and Stefan Adriaensen Contents Current AOT and AC algorithm Overview AOT datasets and retrieval approaches Overview areas Results

More information

Application(s) of Alanine

Application(s) of Alanine Application(s) of Alanine Simon Duane Radiotherapy Standards User Group, 5 June 2007 Outline Alanine/EPR dosimetry characteristics, usage (dis)advantages for reference dosimetry Traceable dosimetry for

More information

Frequency Tracking: LMS and RLS Applied to Speech Formant Estimation

Frequency Tracking: LMS and RLS Applied to Speech Formant Estimation Aldebaro Klautau - http://speech.ucsd.edu/aldebaro - 2/3/. Page. Frequency Tracking: LMS and RLS Applied to Speech Formant Estimation ) Introduction Several speech processing algorithms assume the signal

More information

Lecture 2 BME 599: Modeling & Simulation of Movement

Lecture 2 BME 599: Modeling & Simulation of Movement Simulation Lab #1 Lecture 2 Question of the Day How high can you jump without an approach or swinging your arms? How should you coordinate muscle forces to produce a maximum height jump? Outline for Today

More information

WFC3-IR Thermal Vacuum Testing: IR Channel Dark Current

WFC3-IR Thermal Vacuum Testing: IR Channel Dark Current WFC3-IR Thermal Vacuum Testing: IR Channel Dark Current B. Hilbert and M. Robberto September 9, 2005 ABSTRACT During the 2004 thermal vacuum testing campaign, a series of tests were performed in order

More information

Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites

Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites Electronic Supplementary Material (ESI) for Analytical Methods. Supplementary Material (ESI) for Analytical Methods Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites

More information

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT April 25 nd, 2015 Lung Cancer Lung cancer is the most lethal cancer: Over 224,000 new diagnoses in the U.S. predicted

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

FT-302 Force Transducer

FT-302 Force Transducer Technical Note FT-302 LabScribe is a trademark of 2015 Overview The FT-302 is a high-sensitivity dual-range research grade force transducer designed to measure forces in the 0.005 to 10 gram and 0 to 100

More information

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy C. Talamonti M. Bruzzi,M. Bucciolini, L. Marrazzo, D. Menichelli University of

More information

High-Level Dosimetry systems used at CERN

High-Level Dosimetry systems used at CERN High-Level Dosimetry systems used at CERN Markus Fuerstner 1, Doris Forkel-Wirth 1, Helmut Vincke 1, Sabine Mayer 1, Isabel Brunner 1, Idelette Floret 2 1 CERN, CH-1211 Geneva 23, Switzerland 2 EIG, Ecole

More information

First lasing at the ELBE mid IR FEL

First lasing at the ELBE mid IR FEL First lasing at the ELBE mid IR FEL Peter Michel, Forschungszentrum Rossendorf, PF 510119, 01314 Dresden, Germany p.michel@fz-rossendorf.de ELBE facility - overview ELBE FEL First lasing and results What

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 37-013 GARD Users Manual March 2005 Manual No. 37-013-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective

More information

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions. Lesson 07: Ultrasound Transducers This lesson contains 73 slides plus 16 multiple-choice questions. This lesson was derived from pages 33 through 42 in the textbook: Ultrasound Transducers Ultrasound Transducers

More information

On the feasibility of speckle reduction in echocardiography using strain compounding

On the feasibility of speckle reduction in echocardiography using strain compounding Title On the feasibility of speckle reduction in echocardiography using strain compounding Author(s) Guo, Y; Lee, W Citation The 2014 IEEE International Ultrasonics Symposium (IUS 2014), Chicago, IL.,

More information

Table 1: Samples used in experimental program. Block ID/thickness [ mm ]

Table 1: Samples used in experimental program. Block ID/thickness [ mm ] CONTRIBUTION TO DETECTION AND SIZING LINEAR DEFECTS BY CONVENTIONAL AND PHASED ARRAY ULTRASONIC TECHNIQUES P. Ciorau Ontario Power Generation-Inspection Services Division-NDE Systems Department, Pickering,

More information

ULTRASOUND SIMULATION HELPS TUBE MANUFACTURERS TO CALIBRATE THEIR NDT SYSTEMS S. Deutsch 1, B Bisiaux 1 and P. Gerard 2

ULTRASOUND SIMULATION HELPS TUBE MANUFACTURERS TO CALIBRATE THEIR NDT SYSTEMS S. Deutsch 1, B Bisiaux 1 and P. Gerard 2 ULTRASOUND SIMULATION HELPS TUBE MANUFACTURERS TO CALIBRATE THEIR NDT SYSTEMS S. Deutsch 1, B Bisiaux 1 and P. Gerard 2 1 VALLOUREC, Aulnoye, France; 2 VALTIMET LES LAUMES, Venarey Les Laumes, France Abstract:

More information

H. A. TANAKA (TORONTO/IPP/TRIUMF) MPMTS FOR HK A PERSONAL PERSPECTIVE

H. A. TANAKA (TORONTO/IPP/TRIUMF) MPMTS FOR HK A PERSONAL PERSPECTIVE H. A. TANAKA (TORONTO/IPP/TRIUMF) MPMTS FOR HK A PERSONAL PERSPECTIVE MPMT: Essential features: Vessel providing water-proofing and protection against pressure in additional to photosensors, readout electronics,

More information

Proton and helium beams: the present and the future of light ion beam therapy

Proton and helium beams: the present and the future of light ion beam therapy Proton and helium beams: the present and the future of light ion beam therapy Dr. Andrea Mairani Group Leader Biophysics in Particle Therapy Heidelberg Ion Beam Therapy Center HIT Department of Radiation

More information

Advanced IPD meta-analysis methods for observational studies

Advanced IPD meta-analysis methods for observational studies Advanced IPD meta-analysis methods for observational studies Simon Thompson University of Cambridge, UK Part 4 IBC Victoria, July 2016 1 Outline of talk Usual measures of association (e.g. hazard ratios)

More information

TUTORIAL IN SMALL ANGLE X-RAY SCATTERING ANALYSIS

TUTORIAL IN SMALL ANGLE X-RAY SCATTERING ANALYSIS TUTORIAL IN SMALL ANGLE X-RAY SCATTERING ANALYSIS at the Abdus Salam International Center of Theoretical Physics (ICTP) Heinz Amenitsch Sigrid Bernstorff Michael Rappolt Trieste, 15. May 2006 (14:30-17:15)

More information

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies ICPT School on Medical Physics for Radiation Therapy Justus Adamson PhD Assistant Professor Department of Radiation

More information

Evidence of intrinsic ferromagnetism in individual dilute magnetic semiconducting nanostructures O-K. (a) Zn-L Zn-L 2,3

Evidence of intrinsic ferromagnetism in individual dilute magnetic semiconducting nanostructures O-K. (a) Zn-L Zn-L 2,3 SUPPLEMENTARY INFORMATION Evidence of intrinsic ferromagnetism in individual dilute magnetic semiconducting nanostructures O-K (a) O-K Fe-L Co-L 2,3 2,3 Zn-L Zn-L 2,3 2,3 (b) Intensity (a. u.) 500 750

More information

LHC Physics or How LHC experiments will use OSG resources

LHC Physics or How LHC experiments will use OSG resources LHC Physics or How LHC experiments will use OSG resources OSG Consortium Meeting 08 / 21 / 06 Oliver Gutsche USCMS / Fermilab Particle Physics Probe innermost structure and explain it from first principles

More information

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

IN VIVO IMAGING Proton Beam Range Verification With PET/CT IN VIVO IMAGING Proton Beam Range Verification With PET/CT Antje-Christin Knopf 1/3 K Parodi 2, H Paganetti 1, T Bortfeld 1 Siemens Medical Solutions Supports This Project 1 Department of Radiation Oncology,

More information

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy C. Talamonti a*, M. Bucciolini a, L. Marrazzo a, D. Menichelli a. a) Department

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Biomedical Acoustics Session 1pBAb: Ultrasound Contrast Agents and Passive

More information

STAT 503X Case Study 1: Restaurant Tipping

STAT 503X Case Study 1: Restaurant Tipping STAT 503X Case Study 1: Restaurant Tipping 1 Description Food server s tips in restaurants may be influenced by many factors including the nature of the restaurant, size of the party, table locations in

More information

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus Page 1 of 7 11/18 Candidates are expected to cover all of the content of this syllabus when preparing

More information

FEL oscillation with a high extraction efficiency at JAEA ERL FEL

FEL oscillation with a high extraction efficiency at JAEA ERL FEL FEL oscillation with a high extraction efficiency at JAEA ERL FEL Japan Atomic Energy Agency (JAEA) ERL group Nobuyuki Nishimori, Ryoichi Hajima, Ryoji Nagai, Eisuke Minehara, Masaru Sawamura Nobuhiro

More information

BOOTSTRAPPING CONFIDENCE LEVELS FOR HYPOTHESES ABOUT QUADRATIC (U-SHAPED) REGRESSION MODELS

BOOTSTRAPPING CONFIDENCE LEVELS FOR HYPOTHESES ABOUT QUADRATIC (U-SHAPED) REGRESSION MODELS BOOTSTRAPPING CONFIDENCE LEVELS FOR HYPOTHESES ABOUT QUADRATIC (U-SHAPED) REGRESSION MODELS 12 June 2012 Michael Wood University of Portsmouth Business School SBS Department, Richmond Building Portland

More information

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy Simon Duane, Hugo Palmans, Peter Sharpe NPL, UK Stefaan Vynckier UCL, Brussels, Belgium LNE-LNHB / BIPM workshop,

More information

SYNAPT G2-S High Definition MS (HDMS) System

SYNAPT G2-S High Definition MS (HDMS) System SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business

More information

WEARABLE TREMOR REDUCTION DEVICE (TRD) FOR HUMAN HANDS AND ARMS

WEARABLE TREMOR REDUCTION DEVICE (TRD) FOR HUMAN HANDS AND ARMS Proceedings of the 2018 Design of Medical Devices Conference DMD2018 April 9-12, 2018, Minneapolis, MN, USA DMD2018-6918 WEARABLE TREMOR REDUCTION DEVICE (TRD) FOR HUMAN HANDS AND ARMS Sreekanth Rudraraju

More information

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi Clinical Implementation of a New Ultrasound Guidance System Vikren Sarkar Bill Salter Martin Szegedi Disclosure The University of Utah has research agreements with Elekta Agenda Historical Review Trans-Abdominal

More information

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels

More information