1 special communication Determining bone and total body mineral content from body density and bioelectrical response spectroscopy STEVEN F. SICONOLFI, 1 RANDAL J. GRETEBECK, 2 WILLIAM W. WONG, 3 SHERIL S. MOORE, 4 AND JOHN H. GILBERT III 5 1 Neurosciences Neuromuscular Laboratory, SD3/Space and Life Sciences Research Laboratories, National Aeronautics and Space Administration Johnson Space Center, Houston 77058; 3 Stable Isotope Program, United States Department of Agriculture/Agricultural Research Service Children s Nutrition Research Center, Department of Pediatrics, Baylor College of Medicine, Houston 77030; 4 University Space Research Association, Houston 77058; 5 Aerospace Consultant Enterprises, Houston, Texas 77059; and 2 Department of Foods and Nutrition, Purdue University, West Lafayette, Indiana Siconolfi, Steven F., Randal J. Gretebeck, William W. Wong, Sheril S. Moore, and John H. Gilbert III. Determining bone and total body mineral content from body density and bioelectrical response spectroscopy. J. Appl. Physiol. 85(4): , We hypothesized that one could assess total body mineral (TBM) and bone mineral content (BMC) from measurements of body density and bioelectrical response spectroscopy (BRS)-determined total body water by using a three-compartment (3C) model. We compared TBM and BMC computed from measurements of water ( 2 H 2 O dilution or BRS) and body density (underwater weighing) with [4-compartment (4C)] and without (3C) mineral (dual X-ray absorptiometry) in 15 women and 16 men. BRS used multifrequency or single-frequency estimates of water. Mean differences between the 3C and 4C models ranged from 6.1 to 2.2%. Correlations between models were Standard errors of the estimate of % were within the range of those previously reported, i.e., %. Use of BRS did not significantly decrease the strength of the correlations between the models. A significant mean difference (only in women) was found only with 3C single-frequency BRS estimates of TBM and BMC. We concluded that investigators can assess TBM and BMC 3C multifrequency BRS estimates in men and women. multicompartment models; body composition; underwater weighing; osteoporosis One possible solution uses bioelectrical response spectroscopy (BRS) to assess total body water. BRS comprises the impedance, phase-angle, capacitance, and inductance responses of the human body to a multifrequency input current. A common problem observed with BRS is that the body s impedance shifts as fluid compartments exchange water, such as that observed when a subject moves from a standing to a supine position. The water shift between compartments may take up to 30 min to stabilize. Consequently, estimates of total body water were only valid for the amount of time the subject maintained the position used in the original research study. Siconolfi et al. (18) reported a new approach that eliminated this problem. They showed BRS assessment of total body water to be valid after 0 and 40 min of supine rest. This new BRS, combined with body density, would make remote monitoring of TBM and BMC feasible during spaceflight or in other research studies, such as field evaluation of BMC. However, we must know the effect of using water assessed by BRS on the validity of the Siconolfi et al. (17) model. This study evaluated the validity of the Siconolfi et al. estimates of TBM and BMC from measurements of body density (D b ) and water by using BRS. We evaluated the validity for all subjects (n 31) and subjects by gender (men n 16 and women n 15). SPACEFLIGHT INDUCES physiological adaptations that include decreases in bone mineral content (BMC) (15). Monitoring of BMC with bone densitometers is not possible during spaceflight because of the size and power requirements of present instrumentation. Siconolfi et al. (17) reported that one could assess total body mineral [TBM; 82.4% of which is bone (2)] from measurements of body density and water. During spaceflight, assessing body density is possible because it is the ratio of body mass (available since Skylab) to body volume (portable air-displacement volumometry) (16). The problem is the assessment of total body water on a real-time basis. METHODS Subjects. Thirty-one subjects (16 men and 15 women) participated in this study. All subjects had passed an Air Force Class III physical or its equivalent and were briefed on the study. After all questions about the study were answered, subjects signed an approved informed consent statement. Table 1 lists subject characteristics. Total body water by dilution. This method has been described in detail elsewhere (17). Briefly, subjects reported to the Johnson Space Center in the morning, after an overnight fast, for collection of baseline urine samples. They then drank an oral dose of water containing4gof99.8 atom percent 2 H 2 O (Icon Services, Summit, NJ) diluted to 100 g total volume with tap water. Urine samples collected 3, 4, and 5 h after

2 TBM AND BMC FROM BRS AND BODY DENSITY 1579 Table 1. Subject characteristics Parameter Age, yr Body mass, kg Body density, g/ml Body water, kg BMC, kg %Fat from 4C model administration of the dose were stored frozen in cryogenically stable tubes at 20 C until analysis. We prepared samples according to the procedures of Wong et al. (21) for 2 H: 1 H isotope-ratio measurements by gas-isotope-ratio mass spectrometry. The precision in our laboratory for water is 1% (on the basis of the difference between 4- and 5-h samples from 50 subjects). Total body water by BRS. The full BRS model is described in detail elsewhere (18). Briefly, we recorded BRS from a Hewlett-Packard model 4284A Precision LCR Meter through electrodes placed on the hand, wrist, ankle, and foot at standard locations, before the subject assumed the supine position. BRS uses an average input current of 250 µa (at frequencies of 5, 50, 67, 85, 100, 150, 166, 200, 250, and 300 khz). Subjects reclined in a supine position, and a computer recorded the BRS immediately. We used the Siconolfi et al. (18) parallel electric circuit model to determine water. We regressed (3rd-order least squares regression) each subject s impedance and resistance values on frequency. The mean ( SD) of the correlations for the individualized regressions was The resistance of the total circuit (RT) was the resistance at the frequency where impedance changed by only 1% with a frequency increase of 25 khz. We used the 1% limit because it is an industry standard for high-precision resistors (12). Our laboratory (4) reported that this approach was better than the statistically derived values of the Cole-Cole method. RT estimated water by using the following equation (18) Water (kg) Ht 2 /RT BM model R 0.987; SE of estimate (SEE) 1.26 kg, where Ht is the subject s height (cm), RT is the resistance ( ) of the circuit, and BM is body mass (kg). We also evaluated other BRS estimates of water on the basis of single-frequency responses. The gender-specific equations by Kushner and Schoeller (7) estimated water from Ht 2 /R (resistance at 50 khz) and BM by using the following gender-specific equations Water (kg) (Ht 2 /R) BM men: model R 0.988; SEE kg, and Values are means SD. n 31 Subjects; BMC, bone mineral content; 4C, 4-compartment model. Water (kg) (Ht 2 /R) BM women: model R 0.975; SEE kg. Body density. This protocol is described in a previously published study (17). Briefly, we determined the subject s mass on a beam balance scale and volume by underwater weighing (19). In our laboratory we used a harness and snorkel system that maintains the subject at 2.5 cm below the water surface during the weighing procedures. This reduces the effects of the water acting on the thorax. Water is thought to affect the subject s ability to reach the same residual volume observed outside the tank (3). We found no difference between residual volumes measured in subjects in this position in the water and those measured in a separate group of subjects before weighing. Therefore, we chose not to measure the residual volume during the weighing procedures in this study. The precision ( SD of the difference between 2 measurements) in our laboratory for body density is g/ml (50 subjects were weighed twice). BMC. We assessed BMC with a Hologic QDR 2000 whole body densitometer that employs the technique of dual-energy X-ray absorptiometry (DEXA). The test subject removed all metal (i.e., jewelry) or clothes containing metal before the scan. Subjects wore medical scrubs or other suitable clothing. The technician performing the scans positioned the subject in the supine position on the densitometer for each scan and instructed the subject to remain still during the scan. The Hologic scanned the subject s whole body in the pencil-beam mode. The standard analysis software provided by Hologic (version 5.64) analyzed the scans and reported BMC. Within our laboratory, the precision of the whole body scan is 0.6% (21 subjects were scanned 3 times over 5 days). The same individual performed all scans and scan analyses to avoid interoperator sources of precision error. Many studies report that DEXA measurements of BMC systematically underestimate in vivo neutron activation or chemical analysis values (5, 6, 8, 10, 13, 14, 20). Sabin et al. (14) examined the BMC of three lumbar spines (L 2 L 4 ) from 12 cadavers with DEXA and by ashing at 250 C for 60 h, followed by an additional 24 h of ashing at 500 C. They reported that DEXA systematically underestimated (14%) the ashed BMC. Ho et al. (6) also reported a systematic underestimation of BMC by DEXA. They reported the Hologic BMC to be 5.2% lower than individually ashed (n 31) lumbar spines (11 cadavers), and the regression had a SEE of 8.9%. Sabin et al. suggested that the difference between their results and the Ho et al. results were due to the different temperatures used for ashing the bone. Sabin et al. ashed eight additional vertebrae at the same temperature as did Ho et al. and found a result ( 6.7%) similar to that of Ho et al. Sabin et al. suggested that the higher temperatures used by Ho et al. may have led to chemical changes in the hydroxapatite that account for the smaller mineral content in the ashed vertebrae. Louis et al. (10) reported that neutron activation analysis also underestimated bone mineral ash (3.9%). This difference between the osseous mineral and ashed mineral was similar to that reported by dez et al. (4.3%) (11). Louis et al. also reported that DEXA was 2.2% lower than neutron activation analysis. This yielded a net 6% underestimation of DEXA BMC for the Louis et al. data. Tothill et al. (20) compared BMC from a phantom measured on Hologic, Norland, and Lunar instruments. These authors found Hologic to be 6.7% lower than the phantom (provided by Norland). They also compared BMC of humans across instruments. Hologic and Lunar BMCs were well correlated (r 0.974, Hologic 1.006*Lunar 201.2) but had significantly different means. This suggests that a correction factor should be used when the accuracy of BMC is compared with ashing or neutron activation analyses, when investigators use different bone densitometers. Two of the cadaver studies (6, 10) scanned individual lumbar spines. The BMC of these individual vertebrae are

3 1580 TBM AND BMC FROM BRS AND BODY DENSITY small, g. Lapillone et al. (8) examined the accuracy of Hologic estimates of BMC in small ( 10 g mineral) bone tablets (Ossopan) and reported that the Hologic BMC was % lower than expected. This high degree of variability makes the extrapolation to whole humans difficult. Sabin et al. (14) used the L 2 L 4 values as one measurement to avoid this error. Lapillone et al. noted that, as the BMC increased above 10 g, the error decreased from 10.9 to 3.5%. This suggests that the results of Sabin et al. could be useful as a correction factor. Heymsfield et al. (5) and Pierson et al. (13) compared in vivo neutron activation with Lunar DEXA-determined BMC. We can compare the accuracy of DEXA with this instrument after correcting the Lunar BMC to an equivalent Hologic BMC by using the regression of Tothill et al. (20). Comparing in vivo neutron activation estimate of osseous mineral by Heymsfield et al. to their DEXA data, we found that Lunar DEXA was underestimated by 3.7%. Adjusting their mean Lunar data to an equivalent Hologic response increased the underestimation to 10.8%. Lunar-determined BMC overestimated the in vivo neutron activation value of Pierson et al. by 3.7%. Adjusting their mean Lunar data to an equivalent Hologic response yielded an underestimation of 12.5%. The ashing and neutron activation studies show a range of underestimation of BMC by Hologic DEXA of %. The Heymsfield et al., Pierson et al., and Sabin et al. (14) studies produce a composite correction factor of 11.9% (adjusted for sample size). We applied each correction factor plus the adjusted mean factor to the BMC from the three-compartment (3C) dilution model (3C D ). A repeated-measures ANOVA between the DEXA BMC and corrected 3C D estimates (n 31) showed that only the Ho et al. (6) and Louis et al. (10) correction factors produced significant differences from the Hologic BMC (Table 2). The adjusted mean correction to the three 3C estimates [3C D, multifrequency BRS (3C MB ), and single-frequency BRS (3C SB )] were not significantly different ( 0.3, 1.4, and 3.0%, respectively) from the Hologic BMC for our subjects (Table 2). Therefore, we chose to use the 11.9% correction factor. TBM. Brozek et al. (2) reported that osseous mineral was 82.4% of the TBM content. We followed the suggestion by Lohman (9) and Heymsfield et al. (5) that TBM could be obtained by dividing the corrected BMC by C model assessment of TBM and BMC. Body density and total body water (with 3C D,3C MB,or3C SB ) estimated percent body fat with the following equation (9) %Fat D b w where w is total body water expressed as a fractional component of body mass. This estimate, in combination with body mass, yielded body fat. Fat-free mass (FFM) was the difference between body mass and fat mass. The density of the FFM was computed by using (17) D FFM (1 %fat)/[(1/d b ) (%fat/0.9007)] We used the equation by Siconolfi et al. (17) to determine mineral FFM (m FFM ) m FFM w FFM D FFM Multiplying m FFM by FFM resulted in TBM. BMC was 82.4% of TBM. Statistical analyses. Good validity was present when 1) mean differences between the four-compartment (4C) and 3C values were not significant (repeated-measures ANOVA with Scheffé s post hoc analyses); 2) there was a strong Pearson product-moment correlation; 3) there was a low SEE [expressed as a percentage of the 4C mean (SEE%)]; and 4) there were nonsignificant correlations between the residuals and the averaged values (1), indicating no systematic reason for differences between the methods. Validity was evaluated for all subjects (n 31) and for subjects by gender subgroups. RESULTS The means and SDs of the TBM and BMC for 4C and 3C models are presented in Table 3. Only the validity results for BMC are presented in Table 4. The TBM statistical data were not included in Table 4 because it is a function of BMC and the mean differences, correlations, SEE%, and residual correlations (1) were identical to the BMC data. A key result was the lack of a significant decrease in Pearson product-moment correlations by substituting 3C MB (r 0.90) or 3C SB (r 0.91) estimates of total body water for dilution (r 0.91) for all subjects. Male and female subgroups (Table 4) had similar results. The correlations of residuals (1) Table 2. Effects of literature correction factors on % of 3C estimates of BMC Reference Reference Method Correction Factor r* SEE% of Correction Factor % 3C D 3C MB 3C SB Ho et al. (6) Ashing 5.2% % 7.3% 6.1% 4.4% Louis et al. (10) Ashing 6.0% % 6.4% 5.3% 3.0% Sabin et al. (14) Ashing 14.0% % 2.7% 3.7% 5.3% Heymsfield et al. (5) IVNA 10.5% % 1.0% 0.1% 1.8% Pierson et al. (13) IVNA 12.5% % 1.0% 2.0% 3.6% Adjusted mean 11.9% 0.3% 1.4% 3.0% Uncorrected Hologic 13.9% 12.7% 10.7% %, Percent mean difference; % of 3-compartment model (3C) estimates of BMC (3C Hologic)/Hologic; D, MB, and SB: with dilution and multifrequency and single-frequency bioelectrical response spectroscopy, respectively. * Correlated between dual-energy X-ray absorptiometry (DEXA) BMC and reference method with standard error of the estimate (SEE): SEE expressed as a percentage of the mean reference method (SEE%). Mean adjusted for sample size from Heymsfield et al. (5), Pierson et al. (13), and Sabin et al. (14). In vivo neutron activation analysis (IVNA) adjusted from Lunar BMC to Hologic BMC by using Tothill et al. (19) regression. P 0.05 when compared with Hologic BMC.

4 TBM AND BMC FROM BRS AND BODY DENSITY 1581 Table 3. TBM and BMC assessments from 4C and 3C models in male, female, and all subjects ( 0.08 to 0.36) were not significant, suggesting no systematic over- or underestimation of BMC (Table 4) for all, male, and female subjects. The substitution of the 3C SB model estimates of total body water did produce significantly (P 0.05) lower BMC values ( 6.1%) only for female subjects. The single-frequency BRS model estimates of total body water had excellent correlations (all 0.95; men 0.92; women 0.96) with dilution values but were significantly (P 0.05) larger for all (3.9%), male (4.0%), and female (3.8%) subjects. The multifrequency BRS model estimates of total body water had both excellent correlations (all 0.96; men 0.93; women 0.97) and no significant mean differences for all (1.1%), male (1.0%), and female (1.3%) subjects. SEE% for both methods were similar ( %). DISCUSSION All Subjects, kg, kg, kg TBM 4C DEXA 3, , , C D 3, , , C MB 3, , , C SB 3, , , * BMC 4C DEXA 2, , , C D 2, , , C MB 2, , , C SB 2, , , * Values are means SD. TBM, total body mineral, 4C DEXA, 4-compartment model from DEXA. *P 0.05 compared with 4C DEXA. Table 4. Validity of 3C estimates of BMC in male, female, and all subjects % * vs. 4C DEXA r SEE% Bland-Altman r All Subjects 3C D 0.3% C MB 1.4% C SB 3.0% C D 2.2% C MB 1.7% C SB 0.6% C D 3.6% C MB 5.4% C SB 6.1% *% is 100 (3C 4C DEXA )/4C DEXA based on means. All correlations were significantly different from 0. P 0.05 compared with 4C DEXA. The effects of the single and multifrequency BRS estimates of total body water on the validity of 3C MB and 3C SB determined TBM and BMC were similar. However, the single frequency BRS model estimate of total body water underestimated the 3C SB determined TBM and BMC for the 15 female subjects in the 3C SB model. This underestimation was due to the significantly larger (3.8%) value for water from single frequency BRS compared with the isotopic dilution in our female subjects. The increase in estimated total body water increases the relative percentage of water in the FFM because FFM mass has not changed. This increase in the percentage of water in the FFM is at the expense of the percentage available for mineral and protein. The decrease in the percentage of mineral in the FFM yields smaller values for TBM and BMC. For example, if a person with an actual FFM of 60 kg (consisting of 43.5 kg of water and 16.5 kg of mineral and protein) had an estimated water content of 45.2 kg ( 4% larger than actual), the estimated residual mass decreases by 10% (14.8 kg). Assuming the percent decrease is proportionally ( 27% mineral and 73% protein based on mean female data from Table 1) distributed between mineral and proteins, the reported mineral value would be 2.7% lower than the actual mineral value. The difference between the 3C D and 3C SB models for the female subjects was 2.5%. This study also evaluated the validity of the 3C methods in male subjects. The 3C estimates of BMC were not significantly larger than were the Hologic BMC. The validity for men was equivalent for the three 3C BRS models, despite a 4% overestimation of water with the 3C SB method. This may have been due to the nonsignificant overestimation of the 3C D, which was decreased by the nonsignificant expansion of water. High correlations, small or nonsignificant mean differences, and no systematic error (evident by no significant residual correlations) are only part of the evaluation. The SEE of the 3C methods also must be examined. We expressed the SEEs as a percentage of the mean so that we could compare them to SEEs reported in the literature. Our SEEs ranged from 8.5 to 9.3%. This range of accuracy was within the range reported in the literature (4.9 13%) when DEXA BMC is compared with either ashing (of lumbar spines) or to in vivo neutron activation analysis of humans. Given the error associated with estimating total body water [ 5.6% from multifrequency BRS and 6.6% from singlefrequency BRS (18)] and the 8.8% error in the 3C estimate of BMC (17), the propagated error of using the BRS in the 3C method would be from 10.4 to 10.9%. All of the mean differences and SEEs in this study were less than these expected errors. This suggests that the estimate of BMC from the 3C MB model would be acceptable. The combined methods of a portable air-displacement volumometer (15), calibrated scale, and the BRS instrumentation can permit the assessment of TBM and BMC ( 82.4% of TBM) during spaceflight. These methods also could be used during Earth-based research, such as epidemiologic studies of osteoporosis. These instruments could easily be used in a portable laboratory (trailer) or taken into a subject s home. The total cost of the instruments would be minimal ( $15,000) compared with the cost of bone densitometers and magnetic resonance imagers. We concluded that investigators can assess TBM and BMC from the 3C MB model in men and women.

5 1582 TBM AND BMC FROM BRS AND BODY DENSITY We thank Elisabeth Spector for work with the bone densitometer and Dr. Alan D. Moore for assistance in underwater weighing. Address for reprint requests: S. F. Siconolfi, 121 Shapero Hall/ College of Pharmacy and Allied Health Professions, Wayne State University, Detroit, MI Received 3 April 1997; accepted in final form 15 June REFERENCES 1. Bland, J. M., and D. G. Altman. Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet 1: , Brozek, J., F. Grande, J. T. Anderson, and A. Kemp. Densitometric analysis of body composition: revision of some quantitative assumptions. Ann. NY Acad Sci. 110: , Gibbons, E. S., G. T. Jessup, and C. J. Bunting. Exercise physiology: effect of immersion on residual volume measurements in females. J. Sports Med. Phys. Fitness 25: , Gilbert, J. H., S. S. Suire, R. Gretebeck, W. W. Wong, and S. F. Siconolfi. Effect of frequency, circuit analysis and instrument on extracellular and total body resistance (Abstract). Med. Sci. Sports Exer. 27, Suppl.: S118, Heymsfield, S. B., S. Lichtman, R. N. Baumgartner, J. Wang, and Y. Kamen. Body composition of humans: comparison of two improved four-compartment models that differ in expense, technical complexity, and radiation exposure. Am. J. Clin. Nutri. 52: 52 58, Ho, C. P., R. W. Kim, M. B. Schaffler, and D. J. Sartoris. Accuracy of dual-energy radiographic absortiometry of the lumbar spine: cadaver study. Radiology 176: , Kushner, R. F., and D. A. Schoeller. Estimation of total body water by bioelectrical impedance analysis. Am. J. Clin. Nutr. 44: , Lapillone, A., P. M. Braillon, O. Claris, P. S. Ho, P. D. Delmas, and B. L. Salle. Use of dual-energy X-ray absorptiometry for the measurements of small quantities of mineral. Biol. Neonate. 71: , Lohman, T. G. Advances in Body Composition Assessment. Champaign, IL: Human Kinetics, 1992, p Louis, O., P. VanDen Winkel, P. Covens, A. Schoutes, and M. Osteaux. Dual-energy X-ray absorptiometry of lumbar vertebra: relative contribution of body and posterior elements and accuracy in relation with neutron activation analysis. Bone 13: , dez, J. A., A. Keys, J. R. Anderson, and F. Grande. Density of fat and bone mineral of mammaliam body. Metabolism 9: , Perry, R. H. (Editor). Engineering Manual. A Practical Reference of Data and Methods in Architectural, Chemical, Civil, Electrical, Mechanical, and Nuclear Engineering (2nd ed.). New York; McGraw-Hill, 1959, p Pierson, R. N., Jr., W. J. C. Thornton, D. P. Kotler, S. B. Heymsfield, D. A. Weber, and R. M. Ma. Bone mineral and body fat measurements by two absorptiometry systems: comparison with neutron activation analysis. Calcified Tissue International 56: 93 98, Sabin, M. A., G. M. Blake, S. M. MacLaughlin-Black, and I. Fogelman. The accuracy of volumetric bone density measurements in dual X-ray absorptiometry. Calcified Tissue International 56: , Schneider, V. S., A. D. LeBlanc, and L. C. Taggart. Bone and mineral metabolism. In: Space Physiology and Medicine, edited by A. E. Nicogossian, C. L. Huntoon, and S. L. Pool (3rd ed.). Philadelphia, PA: Lea and Febiger, 1994, p Siconolfi, S. F. Soft-Sided Air Volumometer. Washington, DC: National Aeronautics and Space Administration, (NASA patent application: MSC ) 17. Siconolfi, S. F., R. J. Gretebeck, and W. W. Wong. Assessing total body protein, mineral and bone mineral content from total body water and body density. J. Appl. Physiol. 79: , Siconolfi, S. F., R. J. Gretebeck, W. W. Wong, R. A. Pietrzyk, and S. S. Moore. Assessing total body and extracellular water from bioelectrical response spectroscopy. J. Appl. Physiol. 82: , Sinning, W. E., D. G. Dolny, K. D. Little, L. N. Cunningham, A. Racaniello, S. F. Siconolfi, and J. L. Sholes. Validity of general equations for body composition analysis in male athletes. Med. Sci. Sports Exer. 17: , Tothill, P., A. Avendell, and D. M. Reid. Precision and accuracy of measurements of whole-body bone mineral: comparison between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. Br. J. Radiol. 67: , Wong, W. W., L. S. Lee, and P. D. Klein. Deuterium and oxygen-18 measurements on microliter samples of urine, plasma, saliva, and human milk. Am. J. Clin. Nutr. 45: , 1987.

Bone Mineral and Body Composition Measurements: Cross-Calibration of Pencil-Beam and Fan-Beam Dual- Energy X-Ray Absorptiometers*

Bone Mineral and Body Composition Measurements: Cross-Calibration of Pencil-Beam and Fan-Beam Dual- Energy X-Ray Absorptiometers* JOURNAL OF BONE AND MINERAL RESEARCH Volume 13, Number 10, 1998 Blackwell Science, Inc. 1998 American Society for Bone and Mineral Research Bone Mineral and Body Composition Measurements: Cross-Calibration

More information

Chapter 17: Body Composition Status and Assessment

Chapter 17: Body Composition Status and Assessment Chapter 17: Body Composition Status and Assessment American College of Sports Medicine. (2010). ACSM's resource manual for guidelines for exercise testing and prescription (6th ed.). New York: Lippincott,

More information

Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes

Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes Susumu Sato 1), Shinichi Demura 2), Tamotsu Kitabayashi

More information

EXTRACELLULAR WATER REFERENCE VALUES. Extracellular Water: Reference values for Adults

EXTRACELLULAR WATER REFERENCE VALUES. Extracellular Water: Reference values for Adults CHAPTER 5 Extracellular Water: Reference values for Adults Analiza M. Silva, Jack Wang, Richard N. Pierson Jr., ZiMian Wang, David B. Allison Steven B. Heymsfield, Luis B. Sardinha, Stanley Heshka ABSTRACT

More information

Alterations in growth and body composition during puberty. I. Comparing multicompartment body composition models

Alterations in growth and body composition during puberty. I. Comparing multicompartment body composition models Alterations in growth and body composition during puberty. I. Comparing multicompartment body composition models JAMES N. ROEMMICH, 1 PAMELA A. CLARK, 1 ARTHUR WELTMAN, 2,3 AND ALAN D. ROGOL 1,4 1 Division

More information

Measurement of total body water using 2 H dilution: impact of different calculations for determining body fat

Measurement of total body water using 2 H dilution: impact of different calculations for determining body fat British Journal of Nutrition (2002), 88, 325 329 q The Authors 2002 DOI: 10.1079/BJN2002654 Measurement of total body water using 2 H dilution: impact of different calculations for determining body fat

More information

Body composition analysis by dual energy X-ray absorptiometry in female diabetics differ between manufacturers

Body composition analysis by dual energy X-ray absorptiometry in female diabetics differ between manufacturers European Journal of Clinical Nutrition (1997) 51, 449±454 ß 1997 Stockton Press. All rights reserved 0954±3007/97 $12.00 Body composition analysis by dual energy X-ray absorptiometry in female diabetics

More information

Documentation, Codebook, and Frequencies

Documentation, Codebook, and Frequencies Documentation, Codebook, and Frequencies Dual-Energy X-ray Absorptiometry Femur Bone Measurements Examination Survey Years: 2005 to 2006 SAS Transport File: DXXFEM_D.XPT January 2009 NHANES 2005 2006 Data

More information

Body Composition. Lecture Overview. Measuring of Body Composition. Powers & Howely pp Methods of measuring body composition

Body Composition. Lecture Overview. Measuring of Body Composition. Powers & Howely pp Methods of measuring body composition Body Composition Powers & Howely pp 344-356 Lecture Overview Methods of measuring body composition Two-component system Body fatness for health & fitness Obesity and weight control Diet, exercise, and

More information

Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

Whole Body Dual X-Ray Absorptiometry to Determine Body Composition Page: 1 of 6 Last Review Status/Date: March 2015 Determine Body Composition Description Using low dose x-rays of two different energy levels, whole body dual x-ray absorptiometry (DXA) measures lean tissue

More information

COMPARISON OF BODY COMPOSITION ASSESSMENT IN WOMEN USING SKINFOLD THICKNESS EQUATIONS, BIOELECTRICAL IMPEDANCE ANALYSIS AND UNDERWATER WEIGHING

COMPARISON OF BODY COMPOSITION ASSESSMENT IN WOMEN USING SKINFOLD THICKNESS EQUATIONS, BIOELECTRICAL IMPEDANCE ANALYSIS AND UNDERWATER WEIGHING STUDIES IN PHYSICAL CULTURE AND TOURISM Vol. 17, No. 3, 2010 EFTEKHAR MOHAMMADI, SAEID SHAKERIAN Faculty of Physical Education & Sports Science, Shahid Chamran University, Iran COMPARISON OF BODY COMPOSITION

More information

COMPARISON OF AIR DISPLACEMENT PLETHYSMOGRAPHY TO HYDROSTATIC WEIGHING FOR ESTIMATING TOTAL BODY DENSITY IN CHILDREN

COMPARISON OF AIR DISPLACEMENT PLETHYSMOGRAPHY TO HYDROSTATIC WEIGHING FOR ESTIMATING TOTAL BODY DENSITY IN CHILDREN COMPARISON OF AIR DISPLACEMENT PLETHYSMOGRAPHY TO HYDROSTATIC WEIGHING FOR ESTIMATING TOTAL BODY DENSITY IN CHILDREN Geo Claros 1, Holly R Hull 1, and David A Fields 1,2 * 1 Department of Health and Exercise

More information

Duncan Macfarlane IHP, HKU Parts of this lecture were based on lecture notes provided by the Lindsay Carter Anthropometric Archive, AUT, NZ

Duncan Macfarlane IHP, HKU Parts of this lecture were based on lecture notes provided by the Lindsay Carter Anthropometric Archive, AUT, NZ Body composition assessment issues in athletes 1 Duncan Macfarlane IHP, HKU Parts of this lecture were based on lecture notes provided by the Lindsay Carter Anthropometric Archive, AUT, NZ LEARNING OUTCOMES:

More information

Location of body fat and body size impacts DXA soft tissue measures: a simulation study

Location of body fat and body size impacts DXA soft tissue measures: a simulation study (2008) 62, 553 559 & 2008 Nature Publishing Group All rights reserved 0954-3007/08 $30.00 www.nature.com/ejcn ORIGINAL ARTICLE Location of body fat and body size impacts DXA soft tissue measures: a simulation

More information

ESPEN Congress The Hague 2017

ESPEN Congress The Hague 2017 ESPEN Congress The Hague 2017 Paediatric specificities of nutritional assessment Body composition measurement in children N. Mehta (US) 39 th ESPEN Congress The Hague, Netherlands Body Composition Measurement

More information

Norland Densitometry A Tradition of Excellence

Norland Densitometry A Tradition of Excellence Norland Densitometry A Tradition of Excellence Norland DXA Bone Density Measurement Osteoporosis is a disease marked by reduced bone strength leading to an increased risk of fractures. About 54 million

More information

Body composition techniques and the four-compartment model in children

Body composition techniques and the four-compartment model in children J Appl Physiol 89: 613 620, 2000. Body composition techniques and the four-compartment model in children DAVID A. FIELDS AND MICHAEL I. GORAN Division of Physiology and Metabolism, Department of Nutrition

More information

Bedside methods versus dual energy X-ray absorptiometry for body composition measurement in COPD

Bedside methods versus dual energy X-ray absorptiometry for body composition measurement in COPD Eur Respir J ; 19: 66 631 DOI: 1.1183/931936..796 Printed in UK all rights reserved Copyright #ERS Journals Ltd European Respiratory Journal ISSN 93-1936 Bedside methods versus dual energy X-ray absorptiometry

More information

Body composition in children and adults by air displacement plethysmography

Body composition in children and adults by air displacement plethysmography European Journal of Clinical Nutrition (1999) 53, 382±387 ß 1999 Stockton Press. All rights reserved 0954±3007/99 $12.00 http://www.stockton-press.co.uk/ejcn Body composition in children and adults by

More information

9 Quality Assurance in Bone Densitometry section

9 Quality Assurance in Bone Densitometry section 9 Quality Assurance in Bone Densitometry section Introduction Bone densitometry is frequently used to determine an individual's fracture risk at a particular point in time but may also be used to assess

More information

Assessment of body composition of Sri Lankan Australian children using ethnic specific equations

Assessment of body composition of Sri Lankan Australian children using ethnic specific equations J.Natn.Sci.Foundation Sri Lanka 2015 43 (2): 111-118 DOI: http://dx.doi.org/10.4038/jnsfsr.v43i2.7938 RESEARCH ARTICLE Assessment of body composition of Sri Lankan Australian children using ethnic specific

More information

pqct Measurement of Bone Parameters in Young Children

pqct Measurement of Bone Parameters in Young Children Journal of Clinical Densitometry, vol. 3, no. 1, 9 14, Spring 2000 Copyright 2000 by Humana Press Inc. All rights of any nature whatsoever reserved. 0169-4194/00/3:9 14/$11.50 Original Article pqct Measurement

More information

The Assessment of Body Composition in Health and Disease

The Assessment of Body Composition in Health and Disease The Assessment of Body Composition in Health and Disease Giorgio Bedogni, Paolo Brambilla, Stefano Bellentani and Claudio Tiribelli CHAPTER 3 BODY AND NUTRITIONAL STATUS Nutritional status can be operationally

More information

Validation Study of Multi-Frequency Bioelectrical Impedance with Dual-Energy X-ray Absorptiometry Among Obese Patients

Validation Study of Multi-Frequency Bioelectrical Impedance with Dual-Energy X-ray Absorptiometry Among Obese Patients OBES SURG (2014) 24:1476 1480 DOI 10.1007/s11695-014-1190-5 OTHER Validation Study of Multi-Frequency Bioelectrical Impedance with Dual-Energy X-ray Absorptiometry Among Obese Patients Silvia L. Faria

More information

Luís B Sardinha, Timothy G Lohman, Pedro J Teixeira, Dartagnan P Guedes, and Scott B Going

Luís B Sardinha, Timothy G Lohman, Pedro J Teixeira, Dartagnan P Guedes, and Scott B Going Comparison of air displacement plethysmography with dual-energy X-ray absorptiometry and 3 field methods for estimating body composition in middle-aged men 1,2 Luís B Sardinha, Timothy G Lohman, Pedro

More information

Whole Body Dual X-Ray Absorptiometry (DXA) to Determine Body Composition

Whole Body Dual X-Ray Absorptiometry (DXA) to Determine Body Composition Whole Body Dual X-Ray Absorptiometry (DXA) to Determine Body Composition Policy Number: 6.01.40 Last Review: 4/2018 Origination: 4/2005 Next Review: 4/2019 Policy Blue Cross and Blue Shield of Kansas City

More information

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p. Dedication Preface Acknowledgments Continuing Education An Introduction to Conventions in Densitometry p. 1 Densitometry as a Quantitative Measurement Technique p. 2 Accuracy and Precision p. 2 The Skeleton

More information

Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation

Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation Recent citations - Munawar A Riyadi et al To cite this article:

More information

Bioelectrical impedance analysis to assess body composition in obese adult women: The effect of ethnicity

Bioelectrical impedance analysis to assess body composition in obese adult women: The effect of ethnicity International Journal of Obesity (1998) 22, 243±249 ß 1998 Stockton Press All rights reserved 0307±0565/98 $12.00 Bioelectrical impedance analysis to assess body composition in obese adult women: The effect

More information

DIALYSIS OUTCOMES Quality Initiative

DIALYSIS OUTCOMES Quality Initiative Bipedal Bioelectrical Impedance Analysis Reproducibly Estimates Total Body Water in Hemodialysis Patients Robert F. Kushner, MD, and David M. Roxe, MD Formal kinetic modeling for hemodialysis patients

More information

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA)

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA) 1. RELEVANCE a. This SOP outlines the instructions to completing Duel Energy X-Ray Absorptiometry (DXA) including: scanning, analysis, review and filing. 2. SCOPE a. This SOP applies to all TCRC RDs. 3.

More information

Evaluation of body fat in fatter and leaner 10-y-old African American and white children: the Baton Rouge Children s Study 1 3

Evaluation of body fat in fatter and leaner 10-y-old African American and white children: the Baton Rouge Children s Study 1 3 Original Research Communications Evaluation of body fat in fatter and leaner 10-y-old African American and white children: the Baton Rouge Children s Study 1 3 George A Bray, James P DeLany, David W Harsha,

More information

ESPEN Congress Prague 2007

ESPEN Congress Prague 2007 ESPEN Congress Prague 2007 Nutrition implication of obesity and Type II Diabetes Nutrition support in obese patient Claude Pichard Nutrition Support in Obese Patients Prague, 2007 C. Pichard, MD, PhD,

More information

J EisenkoÈlbl 1, M Kartasurya 1 and K Widhalm 1 * Introduction

J EisenkoÈlbl 1, M Kartasurya 1 and K Widhalm 1 * Introduction (2001) 55, 423±429 ß 2001 Nature Publishing Group All rights reserved 0954±3007/01 $15.00 www.nature.com/ejcn Original Communication Underestimation of percentage fat mass measured by bioelectrical impedance

More information

DEXA Bone Mineral Density Tests and Body Composition Analysis Information for Health Professionals

DEXA Bone Mineral Density Tests and Body Composition Analysis Information for Health Professionals DEXA Bone Mineral Density Tests and Body Composition Analysis Information for Health Professionals PERFORMANCE DEXA is an advanced technology originally used to, and still capable of assessing bone health

More information

The Bone Wellness Centre - Specialists in Dexa Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Bone Wellness Centre - Specialists in Dexa Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 Birth Date: 24.7 years Height / Weight: 8.0 cm 79.0 kg Sex / Ethnic: Male Patient ID: Total Body Tissue Quantitation Composition Reference: Total Tissue 40% 30% 20% 0% 20 30 40 50 60 70 80 90 00 Centile

More information

Body-composition assessment in infancy: air-displacement plethysmography compared with a reference 4-compartment model 1 4

Body-composition assessment in infancy: air-displacement plethysmography compared with a reference 4-compartment model 1 4 Body-composition assessment in infancy: air-displacement plethysmography compared with a reference 4-compartment model 1 4 Kenneth J Ellis, Manjiang Yao, Roman J Shypailo, Alessandro Urlando, William W

More information

JEPonline Journal of Exercise Physiologyonline

JEPonline Journal of Exercise Physiologyonline 26 JEPonline Journal of Exercise Physiologyonline Official Journal of The American Society of Exercise Physiologists (ASEP) ISSN 1097-9751 An International Electronic Journal Volume 6 Number 2 May 2003

More information

N. J. FULLER, S. A. JEBB, M. A. LASKEY', W. A. COWARD and M. ELlA INTRODUCTION

N. J. FULLER, S. A. JEBB, M. A. LASKEY', W. A. COWARD and M. ELlA INTRODUCTION Clinical Science (1992) 82, 687693 (Printed in Great Britain) Fourcomponent model for the assessment of body composition in humans: comparison with alternative methods, and evaluation of the density and

More information

Multi-Compartment Model (MCM) and Body Composition Measurement Techniques

Multi-Compartment Model (MCM) and Body Composition Measurement Techniques White Paper Contents Multi Compartment Model (MCM) 1 Methods comparable to MCM 2 Methods NOT comparable to MCMC 3 References 6 Multi-Compartment Model (MCM) and Body Composition Measurement Techniques

More information

Prediction of extracellular water and total body water by multifrequency bio-electrical impedance in a Southeast Asian population

Prediction of extracellular water and total body water by multifrequency bio-electrical impedance in a Southeast Asian population Asia Pacific J Clin Nutr (1999) 8(2): 155 159 155 Original Article OA 88 EN Prediction of extracellular water and total body water by multifrequency bio-electrical impedance in a Southeast Asian population

More information

Development of a Viable Bedside Ultrasound Protocol to Accurately Predict Appendicular Lean Tissue Mass

Development of a Viable Bedside Ultrasound Protocol to Accurately Predict Appendicular Lean Tissue Mass Development of a Viable Bedside Ultrasound Protocol to Accurately Predict Appendicular Lean Tissue Mass by Michael Paris A thesis presented to the University of Waterloo in fulfillment of the thesis requirement

More information

BODY COMPOSITION COMPARISON: BIOELECTRIC IMPEDANCE ANALYSIS WITH DXA IN ADULT ATHLETES

BODY COMPOSITION COMPARISON: BIOELECTRIC IMPEDANCE ANALYSIS WITH DXA IN ADULT ATHLETES BODY COMPOSITION COMPARISON: BIOELECTRIC IMPEDANCE ANALYSIS WITH DXA IN ADULT ATHLETES A Thesis Presented to the Faculty of the Graduate School University of Missouri In Partial Fulfillment of the Requirements

More information

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 Birth Date: 40.2 years Height / Weight: 158.0 cm 52.0 kg Sex / Ethnic: Female Patient ID: Total Body Tissue Quantitation Composition Reference: Total Tissue 50% 40% 30% 20% 20 30 40 50 60 70 80 90 100

More information

Differences in whole body measurements by DXA-scanning using two Lunar DPX-L machines

Differences in whole body measurements by DXA-scanning using two Lunar DPX-L machines International Journal of Obesity (1999) 23, 764±770 ß 1999 Stockton Press All rights reserved 0307±0565/99 $12.00 http://www.stockton-press.co.uk/ijo Short Communication Differences in whole body measurements

More information

Alice J Yee, Thomas Fuerst, Loren Salamone, Marjolein Visser, Maurice Dockrell, Marta Van Loan, and Marialice Kern

Alice J Yee, Thomas Fuerst, Loren Salamone, Marjolein Visser, Maurice Dockrell, Marta Van Loan, and Marialice Kern Calibration and validation of an air-displacement plethysmography method for estimating percentage body fat in an elderly population: a comparison among compartmental models 1 3 Alice J Yee, Thomas Fuerst,

More information

Bone Mineral Density and Its Associated Factors in Naresuan University Staff

Bone Mineral Density and Its Associated Factors in Naresuan University Staff Naresuan University Journal 2005; 13(3): 13-18 13 Bone Mineral Density and Its Associated Factors in Naresuan University Staff Supawitoo Sookpeng *, Patsuree Cheebsumon, Malinee Dhanarun, Thanyavee Pengpan

More information

In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in

In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in 1 2 In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in adults: the influence of body mass index 3 4 Running title: Precision of the idxa for the measurement of visceral

More information

1. Frequently asked questions

1. Frequently asked questions 1. Frequently asked questions Q. How is BMR calculated by boditrax composition monitors? The electrical signals do not directly measure BMR. They measure electrical impedance, and from this, the weight

More information

Comparison of Body Composition Assessment Techniques in Older Adults

Comparison of Body Composition Assessment Techniques in Older Adults University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange Masters Theses Graduate School 8-2005 Comparison of Body Composition Assessment Techniques in Older Adults Rebekah Ann

More information

Note that metric units are used in the calculation of BMI. The following imperial-metric conversions are required:

Note that metric units are used in the calculation of BMI. The following imperial-metric conversions are required: Body Composition Body Composition: Assessment and Interpretation Body composition has great practical and functional significance for many of us: scientists, clinicians and the general population. It can

More information

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 Patient: Birth Date: 48.2 years Height / Weight: 150.0 cm 72.0 kg Sex / Ethnic: Female

More information

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 Patient: Birth Date: 43.4 years Height / Weight: 170.0 cm 66.0 kg Sex / Ethnic: Female

More information

MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition Medical Policy MP 6.01.40 BCBSA Ref. Policy: 6.01.40 Last Review: 09/19/2018 Effective Date: 09/19/2018 Section: Radiology Related Policies 6.01.44 Vertebral Fracture Assessment With Densitometry 9.01.502

More information

Manipulating Pretesting Conditions for Measuring Body Composition Using the BodPod and Bioelectrical Impedance AN HONORS THESIS (HONR 499)

Manipulating Pretesting Conditions for Measuring Body Composition Using the BodPod and Bioelectrical Impedance AN HONORS THESIS (HONR 499) Manipulating Pretesting Conditions for Measuring Body Composition Using the BodPod and Bioelectrical Impedance AN HONORS THESIS (HONR 499) Jenna Elwert Thesis Advisor Paul Nagelkirk Signed Ball State University

More information

Body-fat measurement in patients with acquired immunodeficiency syndrome: which method should be used?13

Body-fat measurement in patients with acquired immunodeficiency syndrome: which method should be used?13 Original Research Communications-general Body-fat measurement in patients with acquired immunodeficiency syndrome: which method should be used?13 Jack Wang, Donald P Koiler, Man Russell, Santiago Burasiero,

More information

Medical Policy. MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

Medical Policy. MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition Medical Policy MP 6.01.40 BCBSA Ref. Policy: 6.01.40 Last Review: 09/28/2017 Effective Date: 09/28/2017 Section: Radiology End Date: 09/18/2018 Related Policies 6.01.44 Vertebral Fracture Assessment With

More information

patients Bioimpedance analysis of total body water in hemodialysis

patients Bioimpedance analysis of total body water in hemodialysis Kidney International, VoL 46 (1994), pp. 1438 1442 Bioimpedance analysis of total body water in hemodialysis patients L. TAMMY Ho, ROBERT F. KUSHNER, DALE A. SCHOELLER, RANI GuDIvM, and DAVID M. SPIEGEL

More information

Cross-calibration of fat and lean measurements by dualenergy X-ray absorptiometry to pig carcass analysis in the pediatric body weight range13

Cross-calibration of fat and lean measurements by dualenergy X-ray absorptiometry to pig carcass analysis in the pediatric body weight range13 Cross-calibration of fat and lean measurements by dualenergy X-ray absorptiometry to pig carcass analysis in the pediatric body weight range13 Stephen J Pintauro, Tim R Nagy, Christa M Duthie, and Michael

More information

Body composition A tool for nutritional assessment

Body composition A tool for nutritional assessment Body composition A tool for nutritional assessment Ingvar Bosaeus Clinical Nutrition Unit Sahlgrenska University Hospital NSKE Oslo 2012-01-18 Outline What is body composition? What is nutritional assessment?

More information

MEASUREMENT OF BODY COMPOSITION BY IMPEDENCEMETRY NUTRITION CENTRES

MEASUREMENT OF BODY COMPOSITION BY IMPEDENCEMETRY NUTRITION CENTRES Page 1 of 8 1. Scope This procedure is to be followed by the ECRIN Nutrition Centres when performing measurements of body composition by indpendencemetry This procedure describes the steps necessary to

More information

Evaluation of DXA against the four-component model of body composition in obese children and adolescents aged 5 to 21 years

Evaluation of DXA against the four-component model of body composition in obese children and adolescents aged 5 to 21 years Europe PMC Funders Group Author Manuscript Published in final edited form as: Int J Obes (Lond). 2010 April ; 34(4): 649 655. doi:10.1038/ijo.2009.249. Evaluation of DXA against the four-component model

More information

As of the wrestling season, the National

As of the wrestling season, the National Evaluation of Air Displacement for Assessing Body Composition of Collegiate Wrestlers ALAN C. UTTER 1, FREDRIC L. GOSS 2, PAMELA D. SWAN 3, GREGORY S. HARRIS 1, ROBERT J. ROBERTSON 2, and GREGORY A. TRONE

More information

Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition. Original Policy Date 12:2013

Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition. Original Policy Date 12:2013 MP 6.01.28 Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition Medical Policy Section Radiology Is12:2013sue 12:2012 Original Policy Date 12:2013 Last Review Status/Date reviewed

More information

Suprailiac or Abdominal Skinfold Thickness Measured with a Skinfold Caliper as a Predictor of Body Density in Japanese Adults

Suprailiac or Abdominal Skinfold Thickness Measured with a Skinfold Caliper as a Predictor of Body Density in Japanese Adults Tohoku J. Exp. Med., 2007, Measurement 213, 51-61Error Characteristics of Skinfold Caliper 51 Suprailiac or Abdominal Skinfold Thickness Measured with a Skinfold Caliper as a Predictor of Body Density

More information

The estimation of body density in rugby union

The estimation of body density in rugby union LT ERMWORATH Br. J. Sp. Med., Vol. 29, No. 1, pp. 46-51, 1995 Copyright ( 1995 Elsevier Science Ltd Printed in Great Britain. All rights reserved 0306-3674/95 $10.00 + 00 The estimation of body density

More information

Clinical Densitometry

Clinical Densitometry Volume 8 Number 3 Fall 2005 ISSN: 1094 6950 Journal of Clinical Densitometry The Official Journal of The International Society for Clinical Densitometry Editor-in-Chief Paul D. Miller, MD HumanaJournals.com

More information

Evaluating body fat in girls and female adolescents: advantages and disadvantages of dual-energy X-ray absorptiometry 1 4

Evaluating body fat in girls and female adolescents: advantages and disadvantages of dual-energy X-ray absorptiometry 1 4 Evaluating body fat in girls and female adolescents: advantages and disadvantages of dual-energy X-ray absorptiometry 1 4 William W Wong, Albert C Hergenroeder, Janice E Stuff, Nancy F Butte, E O Brian

More information

Roberto D Sainz and Alessandro Urlando

Roberto D Sainz and Alessandro Urlando Evaluation of a new pediatric air-displacement plethysmograph for body-composition assessment by means of chemical analysis of bovine tissue phantoms 1 3 Roberto D Sainz and Alessandro Urlando ABSTRACT

More information

Fitness Assessment Body Composition. PaedDr. Lucia Malá, Ph.D. PaedDr. Tomáš Malý Ing. František Zahálka, Ph.D. prof. Ing. Václav Bunc, CSc.

Fitness Assessment Body Composition. PaedDr. Lucia Malá, Ph.D. PaedDr. Tomáš Malý Ing. František Zahálka, Ph.D. prof. Ing. Václav Bunc, CSc. Fitness Assessment Body Composition PaedDr. Lucia Malá, Ph.D. PaedDr. Tomáš Malý Ing. František Zahálka, Ph.D. prof. Ing. Václav Bunc, CSc. Reviewed by: doc. RNDr. Pavel Bláha, CSc. prof. RNDr. Jarmila

More information

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems? Osteoporos Int (2010) 21:1227 1236 DOI 10.1007/s00198-009-1062-3 ORIGINAL ARTICLE Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems? B. Fan & Y. Lu

More information

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1 Patient: Birth Date: 29.5 years Height / Weight: 156.0 cm 57.0 kg Sex / Ethnic: Female

More information

Bone Densitometry Radiation dose: what you need to know

Bone Densitometry Radiation dose: what you need to know Bone Densitometry Radiation dose: what you need to know John Damilakis, PhD Associate Professor and Chairman University of Crete, Iraklion, Crete, GREECE Estimation of bone status using X-rays Assessment

More information

Stable Isotope Techniques to Develop and Monitor Nutrition Programmes

Stable Isotope Techniques to Develop and Monitor Nutrition Programmes Stable Isotope Techniques to Develop and Monitor Nutrition Programmes A. Introduction The central role of nutrition to development is emphasized by the growing international awareness that the magnitude

More information

Body Composition. Sport Books Publisher 1

Body Composition. Sport Books Publisher 1 Body Composition Sport Books Publisher 1 The body composition The body composition is affected by the proportions of the body component (bones, muscles, and other tissues) It can be seen that the major

More information

Estimation of body composition from bioelectrical impedance of body segments : comparison with dual-energy X-ray absorptiometry

Estimation of body composition from bioelectrical impedance of body segments : comparison with dual-energy X-ray absorptiometry British Journal of Nutrition (1993), 69, 645-655 645 Estimation of body composition from bioelectrical impedance of body segments : comparison with dual-energy X-ray absorptiometry BY S. P. STEWART1, P.

More information

Travis M. Combest, MS, MPH*; Robin S. Howard, MA ; LTC Anne M. Andrews, SP USA (Ret.)

Travis M. Combest, MS, MPH*; Robin S. Howard, MA ; LTC Anne M. Andrews, SP USA (Ret.) MILITARY MEDICINE, 182, 7/8:e1908, 2017 Comparison of Circumference Body Composition Measurements and Eight-Point Bioelectrical Impedance Analysis to Dual Energy X-Ray Absorptiometry to Measure Body Fat

More information

Spinal Cord Rehab Program, Toronto Rehabilitation Institute, University Health Network, 520 Sutherland Drive, Toronto, ON, Canada M4G 3V9 2

Spinal Cord Rehab Program, Toronto Rehabilitation Institute, University Health Network, 520 Sutherland Drive, Toronto, ON, Canada M4G 3V9 2 Journal of Obesity Volume 212, Article ID 936, 9 pages doi:1.11/212/936 Clinical Study Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry Assessments of Changes in Body Composition Following

More information

Understanding Body Composition

Understanding Body Composition PowerPoint Lecture Outlines 7 Understanding Body Composition Objectives Define body composition. Explain why the assessment of body size, shape, and composition is useful. Explain how to perform assessments

More information

Assessing nutritional status after spinal cord injury

Assessing nutritional status after spinal cord injury Assessing nutritional status after spinal cord injury Prof Mary Galea Date: 30 October 2015 Research report #: 078-1015-R01 Further information For further information on this report, please email info@iscrr.com.au

More information

Body composition measurement in severe obesity Sai Krupa Das

Body composition measurement in severe obesity Sai Krupa Das Body composition measurement in severe obesity Sai Krupa Das Purpose of review Severe obesity is accompanied by large increases in fat mass and alterations in the composition of fat free mass, in particular

More information

Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants 1 3

Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants 1 3 Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants 1 3 Winston WK Koo, Mouhanad Hammami, and Elaine M Hockman ABSTRACT Background: Compared

More information

Fitness Concepts + Principles Packet. Name: Period:

Fitness Concepts + Principles Packet. Name: Period: Fitness Concepts + Principles Packet Name: Period: Content Pages + Directions 5 Components of Fitness.................................................... Slides 3-12 FITT Principle.........................................................

More information

Dual-energy Vertebral Assessment

Dual-energy Vertebral Assessment Dual-energy Vertebral Assessment gehealthcare.com Dual-energy Vertebral Assessment More than 40% of women with normal or osteopenic BMD had a moderate or severe vertebral deformation seen with DVA. Patrick

More information

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry Eur Respir J 1998; 12: 960 966 DOI: 10.1183/09031936.98.12040960 Printed in UK - all rights reserved Copyright ERS Journals Ltd 1998 European Respiratory Journal ISSN 0903-1936 New bioelectrical impedance

More information

The Influence of Exogenous Fat and Water on Lumbar Spine Bone Mineral Density in Healthy Volunteers

The Influence of Exogenous Fat and Water on Lumbar Spine Bone Mineral Density in Healthy Volunteers Original Article http://dx.doi.org/10.3349/ymj.2012.53.2.289 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 53(2):289-293, 2012 The Influence of Exogenous Fat and Water on Lumbar Spine Bone Mineral Density

More information

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry R Gilles, Laurentius Ziekenhuis Roermond 1. Introduction Osteoporosis is characterised by low bone mass, disruption of the micro-architecture

More information

Jean-Claude Pineau, PhD*; Jean Robert Filliard, PhDÀ; Michel Bocquet, PhD`

Jean-Claude Pineau, PhD*; Jean Robert Filliard, PhDÀ; Michel Bocquet, PhD` Journal of Athletic Training 2009;44(2):142 147 g by the National Athletic Trainers Association, Inc www.nata.org/jat original research Ultrasound Techniques Applied to Body Fat Measurement in Male and

More information

Lateral Vertebral Analysis DXA Body Composition Quality Assurance in DXA

Lateral Vertebral Analysis DXA Body Composition Quality Assurance in DXA Strong Bone Asia 2013 Osteoporosis in ASEAN Lateral Vertebral Analysis DXA Body Composition Quality Assurance in DXA Chris Schultz Scientist-in-Charge (Bone Densitometry) Royal Adelaide Hospital, Adelaide,

More information

Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition

Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition Policy Number: 6.01.40 Last Review: 4/2014 Origination: 4/2005 Next Review: 4/2015 Policy Blue Cross and Blue Shield of Kansas

More information

Clinical Study Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA

Clinical Study Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA ISRN Obesity Volume 2013, Article ID 462394, 5 pages http://dx.doi.org/10.1155/2013/462394 Clinical Study Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model

More information

Encompass. Eastern Kentucky University. Lee Doernte Eastern Kentucky University. January 2018

Encompass. Eastern Kentucky University. Lee Doernte Eastern Kentucky University. January 2018 Eastern Kentucky University Encompass Online Theses and Dissertations Student Scholarship January 2018 Use Of Dual Energy X-Ray Absorptiometry Measurements To Evaluate Total Body Volume When Compared To

More information

Evaluation and Validation of BODPOD Body Scan Method as Compared to DEXA, Effect of Calcium and Caloric Intake in Female Collegiate Track Athletes

Evaluation and Validation of BODPOD Body Scan Method as Compared to DEXA, Effect of Calcium and Caloric Intake in Female Collegiate Track Athletes Utah State University DigitalCommons@USU Undergraduate Honors Theses Honors Program 5-2010 Evaluation and Validation of BODPOD Body Scan Method as Compared to DEXA, Effect of Calcium and Caloric Intake

More information

Premium solution for your health

Premium solution for your health 770 Premium solution for your health See What You re Made of Reveal the efficiency of your consultation throughout the InBody Test The InBody Test clearly visualize internal change of the body. Weight

More information

This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.

This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving. This is the peer reviewed version of the following article: S, Smith & A. M. Madden (2016) Body Composition and functional assessment of nutritional status in adults: a narrative review of imaging, impedance,

More information

Comparison of Dual-Energy X-Ray Absorptiometry and Dual Photon Absorptiometry for Bone Mineral Measurements of the Lumbar Spine

Comparison of Dual-Energy X-Ray Absorptiometry and Dual Photon Absorptiometry for Bone Mineral Measurements of the Lumbar Spine Comparison of Dual-Energy X-Ray Absorptiometry and Dual Photon Absorptiometry for Bone Mineral Measurements of the Lumbar Spine HENZ W. WAHNER, M.D., WLLAM L. DUNN, M.Sc, MANUEL L. BROWN, M.D., Section

More information

British Journal of Nutrition

British Journal of Nutrition (2008), 99, 432 441 q The Authors 2007 doi: 10.1017/S0007114507815789 Usefulness of different techniques for measuring body composition changes during weight loss in overweight and obese women Cláudia

More information

BODY MASS INDEX AND BODY FAT CONTENT IN ELITE ATHLETES. Abstract. Introduction. Volume 3, No. 2, 2011, UDC :572.

BODY MASS INDEX AND BODY FAT CONTENT IN ELITE ATHLETES. Abstract. Introduction. Volume 3, No. 2, 2011, UDC :572. EXERCISE AND QUALITY OF LIFE Volume 3, No. 2, 2011, 43-48 UDC 796.034.6-051:572.087 Research article BODY MASS INDEX AND BODY FAT CONTENT IN ELITE ATHLETES Jelena Popadiã Gaãeša *, Otto Barak, Dea Karaba

More information

Bioimpedance Spectroscopy for the Estimation of Fat-Free Mass In End-Stage Renal Disease

Bioimpedance Spectroscopy for the Estimation of Fat-Free Mass In End-Stage Renal Disease Bioimpedance Spectroscopy for the Estimation of Fat-Free Mass In End-Stage Renal Disease A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY Sara M. Vine IN PARTIAL

More information

Alexandra M. Johnstone a, Peter Faber b, Eileen R. Gibney c, Gerald E. Lobley a, R. James Stubbs a, Mario Siervo d, ORIGINAL ARTICLE

Alexandra M. Johnstone a, Peter Faber b, Eileen R. Gibney c, Gerald E. Lobley a, R. James Stubbs a, Mario Siervo d, ORIGINAL ARTICLE Obesity Research & Clinical Practice (2014) 8, e46 e54 ORIGINAL ARTICLE Measurement of body composition changes during weight loss in obese men using multifrequency bioelectrical impedance analysis and

More information