Validation Study Registration Form

Size: px
Start display at page:

Download "Validation Study Registration Form"

Transcription

1 TrUSt Validation Study Registration Form This form should be completed by the manufacturer or on behalf of the manufacturer. Study Investigator Details Name Address Mrs.Annemarie de Greef and Professor Andrew Shennan Division of Women's Health King's Health Partners, King's College London 10 Floor North Wing, St thomas' Hospital, Westminster Bridge Road, London SE1 7EH, UNITED KINGDOM Test Device Details Brand Owner Brand JAPAN PRECISION INSTRUMENTS INC. NISSEI Model DSK-1011 Internal Model Number DSK-1011 Manufacturer JAPAN PRECISION INSTRUMENTS INC. OEM Q Initiator Manufacturer Details if "Other" If not initiated by the manufacturer, did the manufacturer agree to the study? Select the correct option on each of the following or, if required, complete the explanation beside "Other". Location Upper Arm Details if "Other" Method Oscillometry Details if "Other" Purpose Other Details if "Other" Clinic and self-measurement Operation Automatic Details if "Other" Automatic: Cuff inflation, deflation and blood pressure determination are fully performed by the device automatically; Semi-automatic: Blood pressure determination is performed automatically but cuff inflation and deflation need manual operation; Manual: Cuff pressure control and blood pressure determination are all performed by manual operation. Cuff details including arm circumference ranges (as recommended by the device manufacturer). Cuffs Small Adult: cm to cm Standard Adult: cm to cm Large Adult: cm to cm Other Universal Cuff: 22 cm to 42cm Wrist Cuff cm to cm Wrist Support Method Other features of the device (about 100 words). Memory function for two persons; indication of pulse pressure on LCD as well as graphical indication of blood pressure range. Ultra modern design with large easy to read display screen and incorporating the latest touch-switches method of operation. Agreement I agree to the publication of the results regardless of whether or not they are favourable to the device., y Signed Jr ( * =L -- ~~~&*~. Company Stamp or Seal Name Yasutomo Kimiura Date 21st July dabl8educational Trust Limited No reproduction of this document is permitted without the written authorisation of daweducational Trust Limited dabl Educational Trust Limited is a not-for-profit organisation. Carraig Court, George's Avenue, Blackrock, Co. Dublin, Ireland Tel info@dableducational.org Form DET1B Fax Web

2 ValidationStudyResultForm Please complete Section 1 to Section 3 of this form and return it to dabl Educational Trust with copies of the validationplots.therequirementsforeachofthesesectionsaredetailedbelowtherespectivetable. Brand Nissei StudyRef. DoNotFill Model DSK 1011 Investigator MrsAnnemariedeGreeff,ProfAndrewShennan Signed Date 3August2011 Section1:Methodology Familiarisation Abriefdescriptionofthefamiliarisationsessionshouldbeprovided.Anydifficultiesshouldbereported. Testmeasurementswereperformedbytrainedstudystaffbeforerecruitinganysubjects.Nodifficultieswereexperienced. Recruitment Thepopulationshouldbeoutlinedandthemethodofselectingthesampleshouldbedescribed.Difficultiesinrecruitment shouldbedescribedandhowtheywereovercome. Population General Detailsif Other Adults above the age of 25 years were recruited from outpatient clinics Kimberley Hospital Complex (Kimberley, South Africa). All patients had a doctor s appointment and none attended for validation purposes specifically/only. Procedure Twoobserverswithanindependentsupervisor Observersblindedfromeachother sreadingsandfromthedevicereadings The European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuringdevicesinadultswasfollowedprecisely. Enter protocol adjustments, as necessary, when the study population is not general with sex, age and blood pressure distributionstatedindetail.theseadjustmentsshould bejustified,withreferences wherepossible.becausechildrenand adolescentshavewiderangeofbodysizeandbloodpressurelevels,thesamplesizeforavalidationstudyshoulddepend onthe studyinclusioncriteria. Thus,for example,a33 subject study wouldbeappropriateonly ifa narrowagerangeof childrenisincluded. Lowestpressurefordiastolicrangeis51mmHgandnot<50mmHg.WewereunabletofindasubjectwithaDBP<50mmHg withintheavailabletimeframeforthestudy,thereforesuchasubjectwasnotincluded. ThisformisintendedforuseonlyinconnectionwithbloodpressuremonitorvalidationstudiescarriedoutinaccordancewiththeprotocoloftheEuropean Society of Hypertension: O Brien E et al. European Society of Hypertension International Protocol revision 2010 for the Validation of Blood Pressure MeasuringDevicesInAdults.BloodPressMonit2010;15: dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited dabl EducationalTrustLimitedisanot for profitorganisation. CarraigCourt,George savenue,blackrock,co.dublin,ireland Tel info@dableducational.org FormDET2B Fax Web

3 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page2of7 Note1: Section2:Results The data from Form 2 Subject Data for each subject should be analysed so that the results on this form can be completed.allreferencestoboxes refertovaluesobtainedfromalloftheForms2fromtherelevantsubjects. Table1:ScreeningandRecruitmentDetails ScreeningandRecruitment RecruitmentRanges TotalScreened TotalExcluded RangesComplete mmhg All OnRx Low < RangeAdjustment Arrhythmias DeviceFailure SBP Medium High > PoorQualitySounds CuffSizeUnavailable ObserverDisagreement Low < Distribution OtherReasons* TotalRecruited DBP Medium High > *ExplanationSummary 313 Box301: Box302: Box303: Box304: Box305: Box306: Box307: Box308: Box309: Box310: Box311: Box312: Box313: Boxes : Thetotalnumberofsubjectsscreened,regardlessofwhetherornottheywereincludedinthestudy. Thetotalnumberexcluded.ThisequalsthesumofBoxes303to311 ThenumberofsubjectsexcludedwithRangesCompletecircledinBox287(Form2foreachexcludedsubject). ThenumberofsubjectsexcludedwithRangeAdjustmentcircledinBox287. ThenumberofsubjectsexcludedwithArrhythmiascircledinBox287. ThenumberofsubjectsexcludedwithDeviceFailurecircledinBox287. ThenumberofsubjectsexcludedwithPoorQualitySoundscircledinBox287. ThenumberofsubjectsexcludedwithCuffSizeAvailabilitycircledinBox287. ThenumberofsubjectsexcludedwithObserverDisagreementcircledinBox287. ThenumberofsubjectsexcludedwithDistributioncircledinBox287. ThenumberofsubjectsexcludedwithOtherReasonscircledinBox287.Asummaryofthosereasonsmustbe providedinbox313. The total recruited equals the number screened (Box301) less the number excluded (Box302). This should equal33exceptinvalidationsinsomespecificpopulations. AsummaryofwhythosecountedinBox311wereexcluded.(Box288) Inacompletedstudyinageneraladultpopulation,thesumofBoxes314&315,Box316,thesumofBoxes317 &318,thesumofBoxes319&320,Box321andthesumofBoxes322&323musteachbebetween10and12. ThesumofBoxes314,318,319&323mustbeatmost4.ThesumofBoxes314to318andthesumofBoxes 319to323musteachbeexactly33.Studiesinspecificpopulationsmayhavedifferentrestrictionsandtotals. (Boxes219and220 Form2foreachincludedsubject) 2011dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

4 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page3of7 Boxes : Thenumberofsubjectsineachrangeonantihypertensivemedication.(Boxes207,219and220) 2011dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

5 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page4of7 Table2:SubjectDetails Sex Male:Female 16: Age(years) Range(Low:High) 25: Mean(SD) 51.7(15.8) 332 ArmCircumference(cm) Range(Low:High) 22: Mean(SD) 30.4(4.4) 334 Small x 335 cm CuffforTestDevice Standard x Large x cm cm Other cm Note2: Box330: Box331: Box332: Box333: Box334: Box335: Box336: Box337: Box338: Box339: Box340: Boxes : Boxes : WristCircumference(cm) (Wristdevicesonly) RecruitmentBP(mmHg) Range(Low:High) : 339 Mean(SD) ( ) 340 SBP DBP Range(Low:High) 101: Mean(SD) 151.2(29.2) : (18.0) 344 The values in Boxes refer only to the final recruited subjects, each of whom contributes SBP and DBP measurementsforanalysis.excludedsubjectsarenotincludedinanyofthisanalysis. Enter the numberofmales,acolonand the numberof females. Theyshouldtotal33 except invalidations in some specific populations. If the minimum requirements (10 for a general population) are not met, subjects mustbereplacedasnecessary.(box206) Entertheageoftheyoungestsubject,acolonandtheageoftheoldestsubjecte.g.31:74.Subjectsoutsidethe requiredrange(25andoverforageneralpopulation)arenotpermitted.(box205) Enterthemeanand,inparentheses,theSDofthesubjectages.Valuesshouldberoundedtoonedecimalplace e.g.52.3(11.9).(box205) Enterthesmallestarmcircumference,acolonandthelargestarmcircumferencee.g.24:34.(Box208) Enterthemeanand, in parentheses,thesdofthe subjectarmcircumferences.valuesshould berounded to onedecimalplacee.g.29.0(3.1).(box208) Ifasmallcuffwassupplied,enterthenumberofsubjectsonwhomitwasused.Ifitwasnotsupplied,enteran X.Enterthearmsizesforwhichitisrecommendedbesideit.(Box209) Enterthenumberofsubjectsonwhomastandard(ormedium)cuffwasused.Enterthearmsizesforwhichitis recommendedbesideit.(box209) Ifalargecuffwassupplied,enterthenumberofsubjectsonwhomitwasused.Ifitwasnotsupplied,enteran X.Enterthearmsizesforwhichitisrecommendedbesideit.(Box209) If a different size cuff was supplied, enter the number of subjects in whom it was used. If no such cuff was supplied,enteran X.Enterthearmsizesforwhichitisrecommendedbesideit.(Box209) Enterthesmallestwristcircumference,acolonandthelargestwristcircumferencee.g.15:22.(Applicableonly forwristdevices)(box210) Enterthemeanand,inparentheses,theSDofthesubjectwristcircumferences.Valuesshouldberoundedto onedecimalplacee.g.18.1(2.3).(applicableonlyforwristdevices)(box210) Enter the lowest pressure, a colon and the highest pressure from BPA measurements only e.g.104:180. (Boxes217and218) Enter the mean and, in parentheses, the SD of the subject pressures from BPA measurements only. Values shouldberoundedtoonedecimalplacee.g.140.4(20.3).(boxes217and218) 2011dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

6 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page5of7 Table3:Distribution Thissectionanalysesthedistributionofcomparativemeasurements. SBP DBP OverallRange(mmHg)Low:High 93: OverallRange(mmHg)Low:High 51: Low(<130mmHg) Low(<80mmHg) Medium(130mmHg 160 mmhg) Medium(80mmHg 100mmHg) High(>160mmHg) High(>100mmHg) Box345: Boxes : Box349 Box350: Boxes : Box354: Note3: Note4: Note5: Note6: MaximumDifference MaximumDifference 12 Enterthelowestpressure,acolonandthehighestSBPfromtheobservermeasurements.(Boxes281,283and 285) The observer measurements (three per subject) for SBP are categorised similarly to the recruitment ranges. Enterthecountsofmeasurementsfallingintoeachrange.Thesemusttotal99.(Boxes281,283and285) SubtractthesmallestvaluefromBoxes346to348fromthelargestoneandentertheresult. Enterthelowestpressure,acolonandthehighestDBPfromtheobservermeasurements.(Boxes282,284and 286) The observer measurements (three per subject) for DBP are categorised similarly to the recruitment ranges. Enterthecountsofmeasurementsfallingintoeachrange.Thesemusttotal99.(Boxes282,284and286) SubtractthesmallestvaluefromBoxes351to353fromthelargestoneandentertheresult. In order to ensure a uniform distribution, there must be at least 22 measurements and at most 44 measurements (Boxes346to348and351to353)ineachofthelow,mediumandhighrangesandthemaximumdifferences(Boxes 349and354)must beatmost19.if not,furtherrecruitmentwillbenecessary.subjectstobeexcluded willbethose whosepressuresdriftedfromrecruitmentpressures. TheoverallSBPrangemustbefrom 100mmHgto 170mmHgandtheoverallDBPrangemustbefrom 50mmHg to 120mmHg.Ifnot,furtherrecruitmentwillbenecessary.Subjectstobeexcludedwillbethelastrecruitedwithin therelevantranges. The minimum number of replacements should take place. If a subject is replaced for either of these reasons, circle DistributioninBox287ofForm2forthatsubject. In validations carried out in specific populations requiring more than 33 subjects but with similar blood pressure distributions, similar proportions should be used. If the blood pressure distribution in the specific population differs fromthestandarddistribution,ignorethistablebutcommentonthedistributioninthediscussion. Table4:ObserverDifferences Thissectionisforthedifferencesinpressuresbetweenthetwoobservers. 354 Observer2 Observer1 SBP(mmHg) DBP(mmHg) RangeLow:High 4:4 355 Mean(SD) 0.3(1.7) 357 4: (1.9) 358 Repeated Measurements Boxes Boxes Boxes359 Enterthelowestdifference,acolonandthehighestdifferencebetweentheobservers.Includethesignse.g. 3:+4.(Boxes247,249,251and253andBoxes248,250,252and254).Iftherangeisoutside 4:+4,thenthisisa violation.relevantsubjectsshouldbeexcluded,byreasonofobserverdisagreement,andreplaced. Enter the mean and, in parentheses, the SD of the observer differences. Values should be rounded to one decimalplacee.g.0.3(1.2).(boxes247,249,251and253andboxes248,250,252and254) Enterthenumberofmeasurementsthatwererepeatedintheincludedsubjectsbecauseobserversweremore than4mmhgapart. 2011dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

7 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page6of7 Table5:ValidationResults Part1 <5mmHg <10mmHg <15mmHg Grade1 Mean(mmHg) SD(mmHg) Pass Requirement Twoof Allof SBP Pass Achieved DBP Pass Part2 2/3<5mmHg 0/3<5mmHg Grade2 Grade3 Pass Requirement >24 <3 Note7: Box360: Box361: Box362: Box363: Achieved SBP 29 DBP Pass 374 Pass 378 Pass Pass Part3 Result Pass 380 Boxes : Box366: Box367: Box368: Box369: Boxes : Box372: Box373: Box374: Box375: Box376: Box377: Box378: Box379: Box380 Note8: Inorderforthedevicetopass,allrequirementsmustbefulfilled.Afailinanypartwillresultinanoverallfail. Enter the number of SBP differences (at most 99) between observer and device measurements falling within 5mmHg.(ThetotalnumberofBoxes273,275and277circledAinthe33subjects) Enter the number of SBP differences (at most 99) between observer and device measurements falling within 10mmHg.(ThetotalnumberofBoxes273,275and277circledAorBinthe33subjects) Enter the number of SBP differences (at most 99) between observer and device measurements falling within 15mmHg.(ThetotalnumberofBoxes273,275and277circledA,BorCinthe33subjects) IfBoxes360,361and362fulfilthePassrequirements,thenthisis Pass ;otherwise,itis Fail. Enter the mean and standard deviation respectively of the 99 SBP differences between observer and device measurements.(usedatafromcircledboxes261or267,263or269and265or271) EnterthenumberofDBP differences(atmost99) betweenobserveranddevicemeasurementsfallingwithin 5mmHg.(ThetotalnumberofBoxes274,276and278circledAinthe33subjects) EnterthenumberofDBP differences(atmost99) betweenobserveranddevicemeasurementsfallingwithin 10mmHg.(ThetotalnumberofBoxes274,276and278circledAorBinthe33subjects) EnterthenumberofDBP differences(atmost99) betweenobserveranddevicemeasurementsfallingwithin 15mmHg.(ThetotalnumberofBoxes274,276and278circledA,BorCinthe33subjects) IfBoxes366,367and368fulfilthePassrequirements,thenthisis Pass ;otherwise,itis Fail. Enter the mean and standard deviation respectively of the 99 DBP differences between observer and device measurements.(usedatafromcircledboxes262or268,264or270and266or272) Enterthenumberofsubjects(atmost33)withtwoorthreeoftheabsolutedifferencesbetweenobserverand devicesbpmeasurementswithin5mmhg.(box279is2or3) Enterthenumberofsubjects(atmost33)withnoneoftheabsolutedifferencesbetweenobserveranddevice SBPmeasurementswithin5mmHg.(Box279is0) IfBoxes372and373fulfilthePassrequirements,thenthisis Pass ;otherwise,itis Fail. IfBoxes363and374areboth Pass,thenthisis Pass ;otherwise,itis Fail. Enterthenumberofsubjects(atmost33)withtwoorthreeoftheabsolutedifferencesbetweenobserverand devicedbpmeasurementswithin5mmhg.(box280is2or3) Enterthenumberofsubjects(atmost33)withnoneoftheabsolutedifferencesbetweenobserveranddevice DBPmeasurementswithin5mmHg.(Box280is0) IfBoxes376and377fulfilthePassrequirements,thenthisis Pass ;otherwise,itis Fail. IfBoxes369and378areboth Pass,thenthisis Pass ;otherwise,itis Fail. IfBoxes375and379areboth Pass,thenthisis Pass ;otherwise,itis Fail. In validations carried out in specific populations requiring more than 33 subjects, proportionally equivalent passing criteriashouldbeused dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

8 dabl EducationalTrust ESH IPValidationStudy Form3 StudyResults Page7of7 Plots Discussion Section3:Closeout Includetheplotswiththisdocument.Confirmthattheycomplywiththerequirements SBP X axis: Range80mmHgto190mmHg Referencelinesat130mmHgand160mmHg Y axis: Range 30mmHgto30mmHg Referencelinesevery5mmHgfrom 15mmHgto15mmHg DBP X axis: Range30mmHgto140mmHg Referencelinesat80mmHgand100mmHg Y axis: Range 30mmHgto30mmHg Referencelinesevery5mmHgfrom 15mmHgto15mmHg No specific problems were encountered during validation and distribution conditions were fulfilled. Recruitment of subjectsinhighpressurerangesweremoredifficultandtimeconsumingthanthoseinmediumor low categories, which is commonly reported in validation studies. There was no subject with a diastolicpressure 50mmHg(ourlowestpressureinthisstudyis51mmHg),butitisclearfromthe aboveplotsthatthiswouldnotinfluencethefinalresultofthestudy.thisisthefirstvalidationof thenisseidsk 1011accordingtoarecognisedvalidationprotocol. Conclusion Theconclusionastowhetherthedeviceisaccurateforuseinthepopulationshouldbestated.Iftheresultsareparticularly sensitivetocorrectuse(e.g.mostwristdevices)thenthiscautionmustbestated. The Nissei DSK 1011 device achieves the standard required by the International Protocol revision 2010 and can be recommendedforclinicalorhomeuse. 2011dabl EducationalTrustLimited Noreproductionofthisdocumentispermittedwithoutthewrittenauthorisationofdabl EducationalTrustLimited

9 Systolic Plot Nissei DSK-1011 Diastolic Plot Nissei DSK-1011

Maker Spacelabs Healthcare Manufacturer Spacelabs Healthcare. Brand Spacelabs Model OnTrak

Maker Spacelabs Healthcare Manufacturer Spacelabs Healthcare. Brand Spacelabs Model OnTrak Validation Study Result Form Please complete Section 1 to Section 3 of this form and return it to dabl Educational Trust with copies of the validation plots and a digital photograph of the device used

More information

Validation Study Result Form

Validation Study Result Form Validation Study Result Form Please complete Section 1 to Section 3 of this form and return it to dabl Educational Trust with copies of the validation plots. The requirements for each of these sections

More information

Validation Study Result Form

Validation Study Result Form Validation Study Result Form Please complete Section 1 to Section 5 of this form and return it to dabl Educational Trust with copies of the validation Study Ref. plots. In Section 3 to Section 5, complete

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval BPW22 with the AViTA BPM15S Devices Item 9 HARTMANN Veroval BPW22 AViTA BPM15S Pictures Display Image Validation Equivalence ESH 2010 ESH 2002 BHS AAMI Category Wrist

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the SAFETY PRONTEX INTEGRA (Nissei DS-B33-03) with the Nissei DSK-1011 Devices Item 9 SAFETY PRONTEX INTEGRA (Nissei DS-B33-03) Nissei DSK-1011 Pictures Display Image Validation ESH IP2010

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval wrist blood pressure monitor with the AViTA BPM15S Devices HARTMANN Veroval wrist blood pressure monitor AViTA BPM15S Pictures Display

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval upper arm blood pressure monitor with the AViTA BPM63S Devices Pictures HARTMANN Veroval upper arm blood pressure monitor AViTA BPM63S

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval BPU22 with the AViTA BPM63S Devices Item 9 HARTMANN Veroval BPU22 AViTA BPM63S Pictures Display Image Validation Equivalence ESH 2010 ESH 2002 BHS AAMI Category Arm Type

More information

Declaration of Equivalence Form

Declaration of Equivalence Form Declaration of Equivalence Form DECLARATION OF BLOOD PRESSURE MEASURING DEVICE EQUIVALENCE 2013 SECTION A - Please complete all items. I Bill Huang,, Name of a Company Director A SIGNED COPY WILL BE POSTED

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the Omron M6 Comfort IT (HEM-7322U-E) with the Omron M6 Comfort (HEM-7321-E) Devices Omron M6 Comfort IT (HEM-7322U-E) Omron M6 Comfort (HEM-7321-E) Pictures Display Validation ESH 2010 Device

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the Microlife BP A150 AFIB with the Microlife BP A100 Plus and Microlife BP A100 Device Equivalence Evaluation Form Devices Microlife BP A150 AFIB 9 Microlife BP A100 Plus 9 Microlife BP

More information

Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus Devices Microlife A2 Basic (BP3GQ1-3P) 9 BP3BT0-A 9 Microlife BP A100 Plus 9 Image 10 10 10 Validation

More information

Received 10 April 2008 Revised 23 June 2008 Accepted 24 June 2008

Received 10 April 2008 Revised 23 June 2008 Accepted 24 June 2008 342 Original article Development of an accurate oscillometric blood pressure device for low resource settings Annemarie de Greeff, Hannah Nathan, Nina Stafford, Bing Liu and Andrew H. Shennan Objective

More information

Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus Devices Microlife A6 PC (BP3GU1-8Y) 9 BP3BT0-A 9 Microlife BP A100 Plus 9 Image 10 10 10 Validation

More information

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension M. EL ASSAAD, J. TOPOUCHIAN, G. LABAKI, R. ASMAR L Institut

More information

Device Judgement Recommended

Device Judgement Recommended dabl Educational Trust Validation Checklist Device Judgement Recommended Manufacturer IEM Device Stabil O Graph Category Upper Arm (Self) Mode Oscillometric Protocol Reference BHS + ESH Westhoff TH, Schmidt

More information

Special articles from the ESH working group on blood pressure monitoring 23

Special articles from the ESH working group on blood pressure monitoring 23 Special articles from the ESH working group on blood pressure monitoring 23 European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices

More information

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany Page 1 of 9 Validation of the TONOPORT VI ambulatory blood pressure monitor, according to the European Society of Hypertension International Protocol revision 2010 Michael Abou-Dakn 1, Cornelius Döhmen

More information

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7]. Devices and technology 37 Validation of the A&D UM-11 professional hybrid device for office blood pressure measurement according to the International Protocol George S. Stergiou, Periklis P. Giovas, Charilaos

More information

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010 Short title: Validation

More information

a Medical Physics Department, Guy s & St Thomas NHS Foundation Trust and b King s College School of Medicine, St Thomas Campus, London, UK

a Medical Physics Department, Guy s & St Thomas NHS Foundation Trust and b King s College School of Medicine, St Thomas Campus, London, UK Devices and technology 27 Validation of the Omron 705IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol Andrew Coleman a, Paul Freeman

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 261 Validation of the ROSSMAX blood pressure measuring monitor according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring

More information

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair:

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair: Page 1 of 10 Validation of the automatic blood pressure measurements device, the OMRON EVOLV (HEM- 7600 T-E) in Pregnancy according to the Modified European Society of Hypertension International Protocol

More information

A GUIDE TO OUR NIBP TECHNOLOGY

A GUIDE TO OUR NIBP TECHNOLOGY GE Healthcare THE DINAMAP DIFFERENCE A GUIDE TO OUR NIBP TECHNOLOGY OUR TECHNOLOGICAL ADVANTAGES THE OSCILLOMETRIC METHODOLOGY Oscillometry is the most commonly used means of indirect blood pressure measurement

More information

STATE OF THE ART BP ASSESSMENT

STATE OF THE ART BP ASSESSMENT STATE OF THE ART BP ASSESSMENT PROFESSOR MOLECULAR PHARMACOLOGY CONWAY INSTITUE UNIVERSITY COLLEGE DUBLIN CO-CHAIRMAN BLOOD PRESCSURE MANAGEMENT IN LOW RESOURCE SETTINGS CENTRE FOR INTERNATIONAL HUMANITARIAN

More information

Methods DEVICES AND TECHNOLOGY

Methods DEVICES AND TECHNOLOGY DEVICES AND TECHNOLOGY Validation of the Omron HEM-907 device for blood pressure measurement Mohamed A. El Assaad, Jirar A. Topouchian, Bernadette M. Darné and Roland G. Asmar Background The aim of this

More information

!"#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33

!#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33 !"#$ Blood Pressure Monitor Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33 Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81 Introduction

More information

AFFORDABLE TECHNOLOGY

AFFORDABLE TECHNOLOGY World Health Organization AFFORDABLE TECHNOLOGY BLOOD PRESSURE MEASURING DEVICES FOR LOW RESOURCE SETTINGS CARDIOVASCULAR DISEASES Blood Pressure Measurement in Low Resource Settings Annex 1: Blood Pressure

More information

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents Original article http://dx.doi.org/10.3345/kjp.2011.54.11.463 Korean J Pediatr 2011;54(11):463-469 Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

More information

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure? MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents 01... Blood Pressure Monitor Intended Use 02... 1. What is blood pressure? 02... 2. Why is it useful measure blood pressure at home?... A. WHO blood pressure

More information

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? DECLARATION OF INTEREST Medical Director and Chairman, Advisory Board dabl Ltd., Dublin, Ireland. BLOOD PRESSURE MEASUREMENT

More information

a Centre de Médecine Cardiovasculaire, Paris, France, b Lebanese Hospital and Received 7 June 2009 Revised 15 September 2009 Accepted 9 October 2009

a Centre de Médecine Cardiovasculaire, Paris, France, b Lebanese Hospital and Received 7 June 2009 Revised 15 September 2009 Accepted 9 October 2009 42 Original article Validation of three professional devices measuring office blood pressure according to three different methods: the Omron BP, the Omron HBP T and the Pic Indolor Professional Roland

More information

Online Supplementary Appendix

Online Supplementary Appendix Online Supplementary Appendix This appendix has been provided by the authors to give readers additional information about their work. Supplement to: Lehman * LH, Saeed * M, Talmor D, Mark RG, and Malhotra

More information

MX3 Plus English. Introduction. Table of contents. 1 How to obtain meaningful blood pressure readings

MX3 Plus English. Introduction. Table of contents. 1 How to obtain meaningful blood pressure readings X3 Plus English X3 Plus Introduction The ORON X3 Plus measures your blood pressure and pulse simply and quickly from the arm, without the use of an inflation bulb or stethoscope. The measurement values

More information

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and Original article 333 Optimum frequency of office blood pressure measurement using an automated sphygmomanometer Martin G. Myers a, Miguel Valdivieso a and Alexander Kiss b,c Objective To determine the

More information

Home Blood Pressure Log

Home Blood Pressure Log Home Blood Pressure Log 2 You or your health care professional may want to monitor your blood pressure at home twice a day for a week or more before appointments to accurately confirm your average blood

More information

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard EOIN O'BRIENt, NEIL ATKINS, JAMES SHERIDAN, COLM KILLEEN, RICHARD COSTELLOE, SHANE LYDON and

More information

There is convincing evidence in clinical studies

There is convincing evidence in clinical studies AJH 1998;11:1413 1417 Reliability of Reporting Self-Measured Blood Pressure Values by Hypertensive Patients Thomas Mengden, Rosa Maria Hernandez Medina, Belen Beltran, Elena Alvarez, Karin Kraft, and Hans

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 223 Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British Hypertension Society protocol Paolo Verdecchia, Fabio Angeli, Roberto Gattobigio,

More information

Blood Pressure Monitors Nissei

Blood Pressure Monitors Nissei We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with blood pressure monitors

More information

HOME DIAGNOSTIC TESTS FOR PERSONAL HEALTH PRODUCT CATALOGUE

HOME DIAGNOSTIC TESTS FOR PERSONAL HEALTH PRODUCT CATALOGUE HOME DIAGNOSTIC TESTS FOR PERSONAL HEALTH PRODUCT CATALOGUE 2 WELCOME TO CIGA HEALTHCARE AND Take Charge of Your Own Health With consumers all over the world becoming increasingly more concerned about

More information

M1 Classic. Digital Blood Pressure Monitor. Instruction manual page 1 SYS. mmhg DIA. mmhg. PULSE/min

M1 Classic. Digital Blood Pressure Monitor. Instruction manual page 1 SYS. mmhg DIA. mmhg. PULSE/min 1 Classic Digital Blood Pressure onitor Instruction manual page 1 1 Classic English Introduction The ORON 1 Classic measures your blood pressure and pulse simply and quickly from the arm, without the use

More information

Home blood pressure measurement with oscillometric upper-arm devices

Home blood pressure measurement with oscillometric upper-arm devices REVIEW Home blood pressure measurement with oscillometric upper-arm devices R.L. Braam, Th. Thien *# Department of Internal Medicine, University Medical Centre St Radboud, PO Box 9101, 6500 HB Nijmegen,

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 57 Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use Takahiro Komori a, Kazuo Eguchi a, Satoshi Hoshide a, Bryan Williams b and Kazuomi

More information

STUDIES INVOLVING THE NON-INVASIVE MEASUREMENT OF BLOOD PRESSURE IN THE ARM

STUDIES INVOLVING THE NON-INVASIVE MEASUREMENT OF BLOOD PRESSURE IN THE ARM STUDIES INVOLVING THE NON-INVASIVE MEASUREMENT OF BLOOD PRESSURE IN THE ARM 1. SCOPE Blood pressure is a vital sign that is used in many clinical situations, and assesses the pressure of blood as it flows

More information

RX-3. Blood Pressure Monitor. Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81

RX-3. Blood Pressure Monitor. Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81 RX-3 Blood Pressure Monitor Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33 Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81 IM-HEM-640-E-01-08/08

More information

Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol

Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol Abstract Objectives Existing concerns over the accuracy of automated blood

More information

BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials.

BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials. AJH 1995; 8:311-315 BRIEF COMMUNICATIONS Lack of Placebo Effect on Ambulatory Blood Pressure Giuseppe Mancia, Stefano Omboni, Gianfranco Parati, Antonella Ravogli, Alessandra Villani, and Alberto Zanchetti

More information

DEVICES AND TECHNOLOGY

DEVICES AND TECHNOLOGY DEVICES AND TECHNOLOGY Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor James M. Wright ab, Gurdial S. Mattu a, Thomas L. Perry Jr ab, Mark E. Gelfer

More information

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients?

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients? O R I G I N A L A R T I C L E Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients? I. Aksoy, J. Deinum, J.W.M. Lenders, Th. Thien *# Department of

More information

Importance Of Taking Manual Blood Pressure In Both Arms

Importance Of Taking Manual Blood Pressure In Both Arms Importance Of Taking Manual Blood Pressure In Both Arms Its importance to health is now well-recognised, in that high blood pressure can lead to Have a look at our slide show on how to take a blood pressure

More information

Use and Interpretation of Home Blood Pressure Monitoring

Use and Interpretation of Home Blood Pressure Monitoring Use and Interpretation of Home Blood Pressure Monitoring BLOOD PRESSURE in year 2015 PARAMETERS TODAY Gianfranco Parati University of Milano-Bicocca & Ospedale S.Luca, IRCCS, Istituto Auxologico Italiano

More information

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination JIRI JILEK 1, MILAN STORK 2 1 Carditech, Culver City, California, USA jilekj@usa.net 2 Dept. of Applied Electronics and

More information

Biomedical Instrumentation E. Blood Pressure

Biomedical Instrumentation E. Blood Pressure Biomedical Instrumentation E. Blood Pressure Dr Gari Clifford Adapted from slides by Prof. Lionel Tarassenko Blood pressure Blood is pumped around the body by the heart. It makes its way around the body

More information

ANNEXURE A SUPPLIER DECLARATION FORM P a g e

ANNEXURE A SUPPLIER DECLARATION FORM P a g e ANNEXURE A SUPPLIER DECLARATION FORM - 1 - P a g e Health Professions Council of South Africa This form must be completed and submitted with TENDER: Health Professions Council of South Africa P O Box 205

More information

Centre for Pre-implantation Genetic Diagnosis Guy s & St Thomas Hospital NHS Foundation Trust. HLA PGD Patient referral form

Centre for Pre-implantation Genetic Diagnosis Guy s & St Thomas Hospital NHS Foundation Trust. HLA PGD Patient referral form Centre for Pre-implantation Genetic Diagnosis Guy s & St Thomas Hospital NHS Foundation Trust HLA PGD Patient referral form Please complete as fully as possible. Incomplete forms and missing data may result

More information

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home. Welch Allyn ABPM 6100S Comprehensive blood pressure monitoring that brings patient comfort home. Features and Benefits of the Welch Allyn ABPM 6100S Pictorial application instructions, artery markers and

More information

The increasing awareness of hypertension as a serious

The increasing awareness of hypertension as a serious AJH 2002; 15:787 792 Evaluation of the Performance of a Wrist Blood Pressure Measuring Device With a Position Sensor Compared to Ambulatory 24-Hour Blood Pressure Measurements Sakir Uen, Burkard Weisser,

More information

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement Direct Care Staff Trained in Accurate BP Measurement 1. 2. 3. 5. 22 to 26 cm Small adult (12X22 cm) 27 to 34 cm Adult (16X30 cm) 35 to 44 cm Large adult (16X36 cm) 45 to 52 cm Adult thigh (16X42 cm) widths

More information

Comparison of blood pressure measured at the arm, ankle and calf

Comparison of blood pressure measured at the arm, ankle and calf doi:10.1111/j.1365-2044.2008.05633.x Comparison of blood pressure measured at the arm, ankle and calf C. Moore, 1 A. Dobson, 2 M. Kinagi 2 and B. Dillon 3 1 SpR Anaesthetics, 2 Consultant Anaesthetist,

More information

Interested parties (organisations or individuals) that commented on the draft document as released for consultation.

Interested parties (organisations or individuals) that commented on the draft document as released for consultation. 23 June 2016 EMA/CHMP/345847/2015 Committee for Medicinal products for Human Use Overview of comments received on ''Guideline on clinical investigation of medicinal products in the treatment of hypertension'

More information

AUTOMATIC WRIST Blood PReSSuRe MonIToR InSTRucTIon Manual

AUTOMATIC WRIST Blood PReSSuRe MonIToR InSTRucTIon Manual Instruction manual AUTOMATIC WRIST Blood Pressure Monitor Automatic Wrist Blood Pressure Monitor Instruction Manual RX803 Table of Contents 1. Introduction 1.1 Features 1.2 Important Information 1.2A

More information

PATIENT INFORMATION. Medicine To Treat: H ypertension. Patient Awareness and Self-Care

PATIENT INFORMATION. Medicine To Treat: H ypertension. Patient Awareness and Self-Care PATIENT INFORMATION Medicine To Treat: H ypertension Patient Awareness and Self-Care WHAT IS BLOOD PRESSURE AND HIGH BLOOD PRESSURE? Blood pressure is the force generated as your heart pumps blood and

More information

/tj7-0zq0 510 (k) Summary P

/tj7-0zq0 510 (k) Summary P /tj7-0zq0 510 (k) Summary P Date Prepared: November 28, 2012 Sponsor Information: Pulsecor Limited DEC i 2o12 Level 2, 135 Morrin Road Auckland 1072, New Zealand Sponsor Contact: Andrew Lowe Telephone:

More information

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

2. Measure a subject's blood pressure and heart rate both at rest and during exercise. Lab Activity 11 The Cardiovascular System Student Learning Objectives After completing this lab, you should be able to: 1. Define, explain and correctly use the key terms. 2. Measure a subject's blood

More information

a ARSMED (Association for Research and Development of Biomedical Received 11 October 2007 Revised 27 March 2008 Accepted 27 March 2008

a ARSMED (Association for Research and Development of Biomedical Received 11 October 2007 Revised 27 March 2008 Accepted 27 March 2008 Analytical methods and statistical analyses 285 PA.NET International Quality Certification Protocol for blood pressure monitors Stefano Omboni a,b, Carlo Costantini a,b,c, Claudio Pini b,d, Roberto Bulegato

More information

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals Product of tradition Premium quality for doctors and hospitals For decades, boso has

More information

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Progress in Clinical Medicine 1 ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Keishi ABE** Asian Med. J. 44(2): 83 90, 2001 Abstract: J-MUBA was a large-scale clinical

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 16 Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-71-E)

More information

BP210 BP250. Automatic Blood Pressure Monitor. Medical Diagnostic Device

BP210 BP250.  Automatic Blood Pressure Monitor. Medical Diagnostic Device Medical Diagnostic Device BP210 BP250 Automatic Blood Pressure Monitor Our best-selling easy-to-use ACCUNIQ Sphygmomanometer ensures fast and accurate results www.accuniq.com ACCUNIQ Brand Introduction

More information

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL) TURNING ON/OFF, CHARGING THE DEVICE On/off button on right side Power supply connector START MENU Current time Battery status Select patient Customize settings Turn off device TESTING Additional information

More information

Webinar Logistics. Now What Do I Need To Do? Blood Pressure in Kids January NC Department of Health and Human Services Division of Public Health

Webinar Logistics. Now What Do I Need To Do? Blood Pressure in Kids January NC Department of Health and Human Services Division of Public Health NC Department of Health and Human Services Division of Public Health Now What Do I Need To Do? Blood Pressure in Kids January 2018 Gerri Mattson, MD, MSPH, FAAP Pediatric Medical Consultant Children and

More information

boso ABI-system 100 inexpensive New feature: PWV Early detection of PAOD: fast, accurate The easy way of checking for measurement option

boso ABI-system 100 inexpensive New feature: PWV Early detection of PAOD: fast, accurate The easy way of checking for measurement option The easy way of checking for risk of HeART ATTACK AND STROKE: boso ABI-system 100 Early detection of PAOD: fast, accurate inexpensive New feature: PWV measurement option Top quality for doctors and clinics

More information

Visiting the Hypertension Unit

Visiting the Hypertension Unit Visiting the Hypertension Unit General Internal Medicine (GIM) Information for patients and families visting the Hypertension Unit at Toronto Western Hospital Read this information to learn about: What

More information

Managing Blood Pressure: It Takes a Team

Managing Blood Pressure: It Takes a Team Managing Blood Pressure: It Takes a Team Module Two How to Take Blood Pressure October 2011 MODULE TWO: How to Take Blood Pressure Module Two: HOW TO TAKE BLOOD PRESSURE Objectives Demonstrate proper technique

More information

LEARNING OUTCOME The students will be able to elicit vital signs correctly on human volunteers/patients

LEARNING OUTCOME The students will be able to elicit vital signs correctly on human volunteers/patients Vital signs (pulse, blood pressure, temperature, respiratory rate, pain) are physiological parameters that a healthcare professional requires when dealing with patients. Accurate measurement of vital signs

More information

Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation

Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation ORIGINAL RESEARCH Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation Tyler S Lamb BSc Amar Thakrar MD, FRCPC Mahua Ghosh MD, PhD Merne P Wilson MSc Thomas W Wilson

More information

IB BP 3AS1-2 VarA5 0906

IB BP 3AS1-2 VarA5 0906 Europe / Middle-East / Africa Microlife AG Max Schmidheiny-Strasse 201 9435 Heerbrugg / Switzerland Tel. +41 / 71 727 70 30 Fax +41 / 71 727 70 39 Email admin@microlife.ch www.microlife.com Asia Microlife

More information

High Blood Pressure Blood Pressure Monitoring at Home -- F...

High Blood Pressure Blood Pressure Monitoring at Home -- F... Return to Web version High Blood Pressure Blood Pressure Monitoring at Home Why should I measure my blood pressure at home and keep a record of it? Measuring your blood pressure at home and keeping a record

More information

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation Vital Signs Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation Aims To ensure that students are able to demonstrate the safe and correct technique for setting up

More information

Microlife WatchBP Home A

Microlife WatchBP Home A Microlife The Microlife is designed to provide reliable and unbiased blood pressure measurement results, and strictly follows European Society of Hypertension (ESH) and American Heart Association (AHA)

More information

Data Collection Worksheet

Data Collection Worksheet Data Collection Worksheet 1. Has a doctor or nurse ever said that you have: High blood pressure or hypertension? [ ] No [ ] Yes [ ] Not Sure 1.a. If Yes, then at what age were you first told this? Age

More information

boso Germany PAOD! The crucial Premium-quality risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system!

boso Germany PAOD! The crucial Premium-quality risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system! PAOD! The crucial risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system! The measurement takes 1 minute and also discovers asymptomatic patients. The new standard for primary

More information

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Acta Medica Marisiensis 2016;62(3):350-355 DOI: 10.1515/amma-2016-0038 UPDATE Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Mako Katalin *, Ureche Corina, Jeremias Zsuzsanna University

More information

The Efficacy of a Self-Harm Awareness Training Programme

The Efficacy of a Self-Harm Awareness Training Programme The Efficacy of a Self-Harm Awareness Training Programme Report of an Independent Evaluation Dr. Ella Arensman Ms. Claire Coffey National Suicide Research Foundation Commissioned by the National Office

More information

The measurement of blood pressure and hypertension. Handout Fenyvesi Tamás III.Department of Medicine

The measurement of blood pressure and hypertension. Handout Fenyvesi Tamás III.Department of Medicine The measurement of blood pressure and hypertension Handout Fenyvesi Tamás III.Department of Medicine 1 2 History of the blood pressure measurement direct Stephen HALES 1726 horse carotid indirect Riva-Rocci

More information

Belfast Autism Assessment and Intervention Services

Belfast Autism Assessment and Intervention Services Belfast Autism Assessment and Intervention Services Autism referral Your child or young person can be referred to our Service from a variety of sources, including GP or Health Visitor, or from an Educational

More information

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER Naser KA. Teaching Hospital Peradeniya, Peradeniya, Sri Lanka Zawahir S

More information

9/27/2016. Adherence and Monitoring of Hypertensive Patients. Conflicts of Interest. Brought to you though a partnership:

9/27/2016. Adherence and Monitoring of Hypertensive Patients. Conflicts of Interest. Brought to you though a partnership: Adherence and Monitoring of Hypertensive Patients. Conflicts of Interest Speaker has no conflicts of interest to disclose I have had no financial relationship over the past 12 months with any commercial

More information

ABPM screen 300/400 Risk Assessment

ABPM screen 300/400 Risk Assessment ABPM screen 300/400 Risk Assessment Highlights of custo screen400 ABPM 24 hours Synchronized ABPM and Holter ECG recordings in combination with custo guard 3 72 hours for ABPM recordings alone To our knowledge,

More information

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved Taking and recording blood pressure and pulse City Gate Training Centre all rights reserved Course Content: Definition of Blood Pressure Normal Blood Pressure Readings Systolic and Diastolic Blood Pressure

More information

Welcome to the S410. Blood Pressure System. Instruction Manual

Welcome to the S410. Blood Pressure System. Instruction Manual Welcome to the S410 Blood Pressure System Instruction Manual The simulator is to be used as part of an approved educational program for healthcare. It is not a substitute for traditional learning methods

More information

Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care

Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care 2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY MEASURE TYPE: Intermediate

More information

Epilepsy and Treatment. Epilepsy Congress Elimination of Epilepsy. World Congress on. September 17-18, Cape Town, South Africa

Epilepsy and Treatment. Epilepsy Congress Elimination of Epilepsy. World Congress on. September 17-18, Cape Town, South Africa Epilepsy Congress 2018 September 17-18, 2018 Cape Town, South Africa World Congress on Epilepsy and Treatment Elimination of Epilepsy epilepsycongress.neuroconferences.com Who attends? Epileptologists

More information

Activity Vital Signs: Heart Rate and Blood Pressure

Activity Vital Signs: Heart Rate and Blood Pressure Activity 8.1.2 Vital Signs: Heart Rate and Blood Pressure Introduction The human body is an amazing machine that automatically monitors and adjusts itself in order to maintain equilibrium or homeostasis.

More information

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE Pamela B. Morris, MD, FACC, FAHA, FASPC, FNLA Professor Medicine and Cardiovascular Diseases Director, Seinsheimer Cardiovascular Health

More information

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Faculty Disclosure I have no financial interest to disclose No off-label use of medications will be discussed FIFTH ANNUAL SYMPOSIUM Recognize changes between

More information

The Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement

The Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement The Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement Jinsong Xu 1., Yanqing Wu 1., Hai Su 1 *, Weitong Hu 1, Juxiang Li 1, Wenying Wang

More information

Primary hypertension in adults

Primary hypertension in adults Primary hypertension in adults NICE provided the content for this booklet which is independent of any company or product advertised Hypertension Welcome NICE published an updated guideline on the diagnosis

More information