The massive, irreparable rotator cuff tear is a challenging

Size: px
Start display at page:

Download "The massive, irreparable rotator cuff tear is a challenging"

Transcription

1 New Solution for Massive, Irreparable Rotator Cuff Tears: The Subacromial Biodegradable Spacer Eugenio Savarese, M.D., Ph.D., and Rocco Romeo, M.D. Abstract: Massive, irreparable rotator cuff tears are a source of pain and disability. Although most rotator cuff tears can be completely repaired, a significant number are considered massive and irreparable. Numerous operative techniques have been described for the treatment of these kinds of tears including arthroscopic debridement, biceps tenotomy, tendon transfer, grafting, and reverse arthroplasty. We describe a surgical technique using a biodegradable subacromial balloon spacer (InSpace; OrthoSpace, Kfar Saba, Israel) implanted between the humeral head and acromion that permits smooth, frictionless gliding, restoring the shoulder biomechanics. The technique is easy to perform and is less invasive than the conventional surgical techniques available, and it may potentially serve as a bridging option in patients with massive, irreparable tears who are normally candidates for reverse arthroplasty. The massive, irreparable rotator cuff tear is a challenging problem to manage. A range of surgical options are available for this condition, including subacromial decompression or debridement, various techniques for partial tendon repair, tendon transfer, muscle-tendon slide procedures, the use of rotator cuff allograft and synthetic graft materials, arthrodesis, hemiarthroplasty, and reverse total shoulder arthroplasty. 1-5 There is no consensus or definitive guidelines concerning the preferred surgical option designed to treat massive, irreparable rotator cuff tears when nonoperative modalities have failed, and it is understood that primary repairs are associated with comparatively poor functional outcomes due to definable muscle atrophy and fatty infiltration 6 and that failed initial surgery is dependent on the size of the From San Carlo Hospital, Potenza, Italy. The authors report that they have no conflicts of interest in the authorship and publication of this article. Received January 9, 2012; accepted February 24, Address correspondence to Eugenio Savarese, M.D., Ph.D., San Carlo Hospital, Potito Petrone, 85100, Potenza, Italy. eugenio.savarese@gmail.com This is a U.S. government work. There are no restrictions on its use. Open access under CC BY-NC-ND license /1213 doi: /j.eats tear. 7 A novel surgical technique uses a biodegradable subacromial spacer, the InSpace balloon (OrthoSpace, Kfar Saba, Israel), implanted between the acromion and the humeral head that permits smooth, frictionless gliding, restoring shoulder biomechanics. The InSpace system contains an introducer and a preshaped spacer made of poly(l-lactide-co- -caprolactone), which is a copolymer of poly-lactide and -caprolactone, a biodegradable and widely used material that biodegrades over a period of 12 months. 8,9 To enable insertion, the balloon is folded into a cylinder-shaped insertion tube, which is removed once the spacer is inserted into the subacromial space. The device is contraindicated for patients with known allergy to device material or patients having active or latent infection or signs of tissue necrosis in the subacromial area. As with any other implantable material, the expected risks after implantation may include foreign body response, local irritation at the wound site, local infection, inflammation, and tissue necrosis. Moreover, device displacement may occur and increase pain. All mentioned adverse effects are relatively rare and can be treated by routine medications such as antibiotics and/or injectable steroids. Alternatively, the implant can be punctured or removed by an arthroscopic procedure. Additional highlights and tips Arthroscopy Techniques, Vol 1, No 1 (September), 2012: pp e69-e74 e69

2 e70 E. SAVARESE AND R. ROMEO TABLE 1. Highlights and Tips for InSpace Use Indications Torn and irreparable supraspinatus Torn and irreparable supraspinatus and torn and reparable infraspinatus Torn and irreparable supraspinatus and infraspinatus Torn and irreparable supraspinatus, torn and reparable or irreparable infraspinatus, and torn and reparable subscapularis Contraindications Glenohumeral arthropathy Active or latent infection or tissue necrosis Allergy to device material (poly-lactide and poly- caprolactone) Axillary palsy Risks* Spacer displacement Tissue responses to implant, which could include local irritation, infection, and inflammation Pitfalls and tips The lateral port should be made parallel to the supraglenoid tubercle to enable easy insertion and correct orientation of the device. Debridement and bursectomy should be performed to allow proper selection of spacer size and to enable correct positioning to minimize implant displacement risk. In cases where the measurement of the distance between the glenoid rim and the lateral border of the acromion falls between 2 spacer sizes (e.g., 49 mm, which is borderline between the small and medium spacer sizes), the larger spacer size should be used (to minimize implant displacement). Using a probe through the anterior port could assist in achieving stabilization and proper placement of the device. It is highly recommended to follow the manufacturer s instructions regarding inflation volumes and avoid overinflation. To avoid over-tensioning of the deltoid muscle. In case of a torn subscapularis, reconstruction is recommended. In case of a partially torn long head of the biceps, biceps tenotomy or tenodesis is recommended. It is recommended to repair the subscapularis to create anterior/posterior coupling before spacer insertion. If the subscapularis is irreparable, spacer implantation should be considered with caution. *The risks mentioned are relatively rare and may occur with every implantable device. If adverse effects occur, they can be treated by routine medications or by arthroscopic puncture and/or removal of the device. are described in Table 1, and the treatment algorithm is further described in Fig 1. The InSpace insertion technique is easy to perform, less invasive than many other procedures, reproducible, and safe, with initial results showing efficacy that is maintained beyond the 12-month period of natural biodegradation of the implant. TECHNIQUE The patient is placed either on a beach chair or in the lateral decubitus position (Video 1). The standard arrangement for arthroscopic rotator cuff repair requires a 50-mL Luer-lock syringe filled with 0.9% saline solution prewarmed to 40 C and an extension tube connected to a 3-way valve. Step 1 A standard posterior arthroscopic port is inserted to explore the joint and to allow glenohumeral visualization and treatment of shoulder pathology as indicated. Step 2 Subacromial visualization is conducted through the posterior port while the surgeon inserts a needle into the subacromial space using a secondary lateral arthroscopic port. The lateral 1.5-cm port is made parallel to the supraglenoid tubercle, where placement of this port is critical to permit easy insertion and correct orientation of the balloon system. Step 3 Debridement and/or bursectomy is performed with a shaver to allow better visualization of the subacromial space and to define the type and extent of rotator cuff tear. The soft tissue over the glenoid rim and the rotator cuff muscle stump is cleaned to a level that permits insertion and accurate positioning of the spacer. Step 4 The InSpace subacromial spacer is available in 3 different sizes: small (40 50 mm), medium (50 60 mm), and large (60 70 mm) (Table 2). To select the appropriate spacer size, measurements are made with an arthroscopic probe with marked lines, where the medial point is defined 1 cm medial to the superior glenoid rim and the lateral point is the lateral border of the acromion (Figs 2 and 3). In those cases where the measurement lies between 2 main sizes, the larger spacer size is used to ensure proper positioning and to minimize the likelihood of implant displacement. Step 5 The biodegradable spacer is introduced through the lateral port. The system should be placed approximately 1 cm over the glenoid rim and the rotator cuff tendon stump, inside the medial point. There is a

3 MASSIVE, IRREPARABLE ROTATOR CUFF TEARS e71 FIGURE 1. InSpace treatment algorithm. (ISP, infraspinatus; SSP, supraspinatus; SUBSCAP, subscapularis.) lateral (black) marker on the system deployer that should be in line with the lateral border of the acromion (Fig 4). In some patients this step can be challenging and may require stabilization and placement assistance by advancing a probe through the anterior port (Fig 5). Step 6 Once accurate positioning of the spacer is achieved, the protective sheath is withdrawn to reveal the spacer (Fig 6). The extension tubing is connected to the distal side of the Luer-lock connector, and the spacer is inflated to its maximal volume depending on the spacer size. The valve should remain open to permit backflow of saline solution into the syringe until the recommended volume is achieved that allows a full range of motion of the shoulder. It is important to maintain the recommended volume because spacer overinflation may result in excessive tension in the deltoid muscle with pain, as well as an increased likelihood of device displacement over time. It is preferable that, if the correct volume cannot be maintained, the balloon should remain slightly underinflated to avoid these complications. Step 7 The spacer is sealed and secured in situ by firmly grasping the deployer and withdrawing the connecting syringe (Figs 7 and 8). As a final step, the delivery system is removed, and the shoulder is passively moved through a full range of movement to verify that the spacer is accurately placed, is stable in position, and does not interfere with shoulder mobility. TABLE 2. InSpace Spacer Size and Recommended Inflation Volumes Balloon Size Width (mm) Length (mm) Maximal Inflation Volume (ml) Recommended Final Volume (ml) Small Medium Large FIGURE 2. Definition of medial point in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and arthroscopic probe in lateral portal.

4 e72 E. SAVARESE AND R. ROMEO FIGURE 3. Definition of lateral point in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and arthroscopic probe in lateral portal. FIGURE 5. Assistance in spacer (balloon) deployment using probe in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and arthroscopic probe in anterior portal. DISCUSSION Massive, irreparable rotator cuff tears are a challenging problem, and tears of the posterior cuff result FIGURE 4. Lateral marker of spacer sheath (arrow) in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and spacer sheath in lateral portal. in humeral head migration and narrowing of the subacromial space. Although, on occasion, a shoulder with this pathology can retain acceptable stability, it is frequently very painful and effectively nonfunctional. In recent publications, numerous management strategies have been used, and studies have shown varied results with regard to shoulder pain, range of motion, strength, and overall improvement of shoulder function, with no consensus regarding the optimal treatment solution for this patient population. Longo et al. 10 summarized 22 retrospective nonrandomized studies describing 493 shoulders, in which latissimus dorsi tendon transfer by an arthroscopic, open, or combined approach as a single procedure or in combination with other muscle-tendon transfer procedures, replacement, or both has been proposed as a possible solution to restore pain-free function, strength, and range of motion in patients with massive, irreparable cuff tears. Lee et al. 11 presented satisfactory results with good preservation of the preoperative and postoperative acromiohumeral interval and continuity in the inferior scapulohumeral line, diminishing pain, and improvement of active forward elevation in 36 patients with irreparable, massive rotator cuff tears who were followed up for at least 3 years after arthroscopic tuberoplasty with concomitant acromioplasty, as well as treatment of the biceps tendon when indicated. Gupta et al. 12 described a prospective ob-

5 MASSIVE, IRREPARABLE ROTATOR CUFF TEARS e73 FIGURE 6. (A) Partially exposed spacer and (B) fully exposed spacer in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and spacer in lateral portal. servational study of 24 patients who underwent interposition repair of massive rotator cuff tears with human dermal allograft; all patients showed a significant improvement in pain, range of motion, and strength, with ultrasonography-confirmed fully intact repairs in 76% of patients who were followed up for a 3-year period on average. Glanzmann et al. 13 performed retrospective assessment of 31 deltoid flap transfers for massive posterosuperior rotator cuff tears at midterm and long-term follow-up examinations (mean, 53 and 175 months, respectively). They showed that functional gains were minor but improvement in pain and patient satisfaction was high. Survival rates for the deltoid flap, confirmed by ultrasound, were 16.5% at midterm follow-up and 12.5% at long-term follow-up. Cranial migration of the humeral head progressed in all cases in their study and could not be prevented by the interposition of a deltoid flap. On the basis of these results, Glanzmann et al. no longer use or recommend this technique. Mulieri et al. 7 presented reverse shoulder arthroplasty as a treatment option for patients who had persistent shoulder pain and dysfunction despite a minimum of 6 months of nonoperative treatment with the presence of at least a 2-tendon tear without glenohumeral arthritis. Significant pain relief, along with an improvement in range of motion, was achieved in the 58 patients (60 shoulders) who were evaluated for a minimum of 2 years of follow-up. Nevertheless, this treatment option is a salvage procedure involving major surgery and is associated with a relatively high complication rate (prevalence, 20%). A balloon implantation technique was previously described by Sartoretti et al. 14 for the ankle joint. Kilinc et al. 15 used a Foley catheter that was cut just proximal to the balloon end and inserted into the subacromial space to allow better visualization, triangulation of the arthroscopic instruments, and anatomic repair of the rotator cuff tendon. To our knowledge, this is the first report of the use of the innovative device and technique described for the treatment of patients with massive, irreparable full-thickness rotator cuff tears due to trauma or deg- FIGURE 7. Final step of deployment and sealed spacer in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and spacer in lateral portal.

6 e74 E. SAVARESE AND R. ROMEO REFERENCES FIGURE 8. Inflated spacer over humeral head in left shoulder with patient in beach-chair position, arthroscope in posterior portal, and spacer in lateral portal. The sealing mechanism is marked with an arrow. radation. The rotator cuff normally provides stability by compression of the humeral head into the glenoid, whereas rotator cuff disruption compromises concavity compression and alters glenohumeral load structure and direction. The deployment of a balloon spacer should reduce subacromial friction during shoulder abduction by lowering the head of the humerus and facilitating humeral gliding against the acromion during movement. The spacer degrades within 12 months, which is a period that conforms well to the rehabilitation time frame after any arthroscopic procedure performed on the rotator cuff. It is unclear, however, how long the spacer remains inflated, and it is not understood why pain and functional scores continue to improve beyond the period of spacer disintegration. 1. Moser M, Jablonski MV, Horodyski M, Wright TW. Functional outcome of surgically treated massive rotator cuff tears: A comparison of complete repair, partial repair, and debridement. Orthopedics 2007;30: Cole BJ, ElAttrache NS, Anbari A. Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations. Arthroscopy 2007;23: Cuff D, Pupello D, Virani N, Levy J, Frankle M. Reverse shoulder arthroplasty for the treatment of rotator cuff deficiency. J Bone Joint Surg Am 2008;90: MacDonald PB, Altamimi S. Principles of arthroscopic repair of large and massive rotator cuff tears. Instr Course Lect 2010;59: Goutallier D, Postel JM, Bemageau J, et al. Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res 2007: Matthews TJ, Hand GC, Rees JL, Athanasou NA, Carr AJ. Pathology of the torn rotator cuff tendon. Reduction in potential for repair as tear size increases. J Bone Joint Surg Br 2006;88: Mulieri P, Dunning P, Klein S, Pupello D, Frankle M. Reverse shoulder arthroplasty for the treatment of irreparable rotator cuff tear without glenohumeral arthritis. J Bone Joint Surg Am 2010;92: Burks CA, Bundy K, Fotuhi P, Alt E. Characterization of 75:25 poly(l-lactide-co-epsilon-caprolactone) thin films for the endoluminal delivery of adipose-derived stem cells to abdominal aortic aneurysms. Tissue Eng 2006;12: Levy Y, Paz A, Ben Yosef R, et al. Biodegradable inflatable balloon for reducing radiation adverse effects in prostate cancer. J Biomed Mater Res B Appl Biomater 2009;91: Longo UG, Franceschetti E, Petrillo S, Maffulli N, Denaro V. Latissimus dorsi tendon transfer for massive irreparable rotator cuff tears: A systematic review. Sports Med Arthrosc 2011; 19: Lee BG, Cho NS, Rhee YG. Results of arthroscopic decompression and tuberoplasty for irreparable massive rotator cuff tears. Arthroscopy 2011;27: Gupta AK, Hug K, Berkoff DJ, et al. Dermal tissue allograft for the repair of massive irreparable rotator cuff tears. Am J Sports Med 2012;40: Glanzmann MC, Goldhahn J, Flury M, Schwyzer HK, Simmen BR. Deltoid flap reconstruction for massive rotator cuff tears: Mid- and long-term functional and structural results. J Shoulder Elbow Surg 2010;19: Sartoretti C, Sartoretti-Schefer S, Duff C, Buchmann P. Angioplasty balloon catheters used for distraction of the ankle joint. Arthroscopy 1996;12: Kilinc AS, Ebrahimzadeh MH, Lafosse L. Subacromial internal spacer for rotator cuff tendon repair: The balloon technique. Arthroscopy 2009;25:

Options for the Irreparable RCT 3/9/2018. Your Patient has an Irreparable RC Tear: What Now? Asheesh Bedi, MD

Options for the Irreparable RCT 3/9/2018. Your Patient has an Irreparable RC Tear: What Now? Asheesh Bedi, MD Your Patient has an Irreparable RC Tear: What Now? Asheesh Bedi, MD Harold and Helen W. Gehring Professor Chief, Sports Medicine & Shoulder Surgery MedSport, Department of Orthopedic Surgery Head Team

More information

11/13/2017. Disclosures: The Irreparable Rotator Cuff. I am a consultant for Arhtrex, Inc and Endo Pharmaceuticals.

11/13/2017. Disclosures: The Irreparable Rotator Cuff. I am a consultant for Arhtrex, Inc and Endo Pharmaceuticals. Massive Rotator Cuff Tears without Arthritis THE CASE FOR SUPERIOR CAPSULAR RECONSTRUCTION MICHAEL GARCIA, MD NOVEMBER 4, 2017 FLORIDA ORTHOPAEDIC INSTITUTE Disclosures: I am a consultant for Arhtrex,

More information

Massive Rotator Cuff Tears. Rafael M. Williams, MD

Massive Rotator Cuff Tears. Rafael M. Williams, MD Massive Rotator Cuff Tears Rafael M. Williams, MD Rotator Cuff MRI MRI Small / Partial Thickness Medium Tear Arthroscopic View Massive Tear Fatty Atrophy Arthroscopic View MassiveTears Tear is > 5cm

More information

Management of Massive/Revision Rotator Cuff Tears

Management of Massive/Revision Rotator Cuff Tears Management of Massive/Revision Rotator Cuff Tears Nikhil N. Verma MD, Director Sports Medicine, Rush University Medical Center, Midwest Orthopedics at Rush, Chicago, IL nverma@rushortho.com I. Anatomy

More information

SHOULDER ANATOMY AND FUNCTION. Disclosure. Case. Learning Objectives MRI. Plan? 3/23/2017 5

SHOULDER ANATOMY AND FUNCTION. Disclosure. Case. Learning Objectives MRI. Plan? 3/23/2017 5 Disclosure Doc, My Shoulder Keeps me Up at Night! Evaluation and Treatment of Atraumatic Shoulder Pain Matthew F. Dilisio, MD Shoulder and Elbow Surgery, CHI Health Orthopedics Assistant Professor, Creighton

More information

The Irreparable Rotator Cuff Tear:

The Irreparable Rotator Cuff Tear: The Irreparable Rotator Cuff Tear: Trauma 101: Shoulder Session #2 Brian Grawe, MD Assistant Professor Orthopaedics & Sports Medicine 5/10/2018 Brian Grawe, MD Assistant Professor Phone Number: 513-558-4516

More information

Inserting a biodegradable subacromial spacer for rotator cuff tears

Inserting a biodegradable subacromial spacer for rotator cuff tears NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE Interventional procedure consultation document Inserting a biodegradable subacromial spacer for rotator cuff tears The rotator cuff is a group of muscles

More information

Management of arthritis of the shoulder. Omar Haddo Consultant Orthopaedic Surgeon

Management of arthritis of the shoulder. Omar Haddo Consultant Orthopaedic Surgeon Management of arthritis of the shoulder Omar Haddo Consultant Orthopaedic Surgeon Diagnosis Pain - with activity initially. As disease progresses night pain is common and sleep difficult Stiffness trouble

More information

Considerations 3/9/2018. Asheesh Bedi, MD. I have no disclosures or conflicts of interest related to the content of this presentation.

Considerations 3/9/2018. Asheesh Bedi, MD. I have no disclosures or conflicts of interest related to the content of this presentation. Radiological Assessment of the Rotator Cuff What predicts outcomes? Asheesh Bedi, MD Harold and Helen W. Gehring Professor Chief, Sports Medicine & Shoulder Surgery MedSport, Department of Orthopedic Surgery

More information

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE INTERVENTIONAL PROCEDURES PROGRAMME Interventional procedure overview of inserting a biodegradable subacromial spacer for rotator cuff tears The rotator

More information

06/Μαρ/2013 FUNCTION OF THE ROTATOR CUFF. ARTHROSCOPIC ROTATOR CUFF REPAIR Primarily to stabilize and centralize the humeral head GENERAL GUIDE LINES

06/Μαρ/2013 FUNCTION OF THE ROTATOR CUFF. ARTHROSCOPIC ROTATOR CUFF REPAIR Primarily to stabilize and centralize the humeral head GENERAL GUIDE LINES FUNCTION OF THE ROTATOR CUFF ARTHROSCOPIC ROTATOR CUFF REPAIR Primarily to stabilize and centralize the humeral head GENERAL GUIDE LINES Achieved by balancing the force couples in coronal and transverse

More information

Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuv tears

Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuv tears DOI 10.1007/s00590-012-0981-4 ORIGINAL ARTICLE Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuv tears Vladimir Senekovic Boris Poberaj

More information

ROTATOR CUFF DISORDERS/IMPINGEMENT

ROTATOR CUFF DISORDERS/IMPINGEMENT ROTATOR CUFF DISORDERS/IMPINGEMENT Dr.KN Subramanian M.Ch Orth., FRCS (Tr & Orth), CCT Orth(UK) Consultant Orthopaedic Surgeon, Special interest: Orthopaedic Sports Injury, Shoulder and Knee Surgery, SPARSH

More information

RCR or rtsa? Massive Rotator Cuff Tears without Arthritis in Patients Older than 65 Reverse Total Shoulder Arthroplasty or Rotator Cuff Repair?

RCR or rtsa? Massive Rotator Cuff Tears without Arthritis in Patients Older than 65 Reverse Total Shoulder Arthroplasty or Rotator Cuff Repair? Massive Rotator Cuff Tears without Arthritis in Patients Older than 65 Reverse Total Shoulder Arthroplasty or Rotator Cuff Repair? JESSE W. ALLERT, MD THOMAS SELLERS, MD PETER SIMON, PHD RACHEL CLARK,

More information

DK7215-Levine-ch12_R2_211106

DK7215-Levine-ch12_R2_211106 12 Arthroscopic Rotator Interval Closure Andreas H. Gomoll Department of Orthopedic Surgery, Brigham and Women s Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A. Brian J. Cole Departments

More information

Shoulder Arthroscopy. Dr. J.J.A.M. van Raaij. NOV Jaarvergadering Den Bosch 25 jan 2018

Shoulder Arthroscopy. Dr. J.J.A.M. van Raaij. NOV Jaarvergadering Den Bosch 25 jan 2018 Shoulder Arthroscopy Dr. J.J.A.M. van Raaij NOV Jaarvergadering Den Bosch 25 jan 2018 No disclosures Disclosure Shoulder Instability Traumatic anterior Traumatic posterior Acquired atraumatic Multidirectional

More information

Shoulder Arthroscopy Lab Manual

Shoulder Arthroscopy Lab Manual Shoulder Arthroscopy Lab Manual Dalhousie University Orthopaedic Program May 5, 2017 Skills Centre OBJECTIVES 1. Demonstrate a competent understanding of the arthroscopic anatomy and biomechanics of the

More information

Shoulder Arthroscopy Portals

Shoulder Arthroscopy Portals Shoulder Arthroscopy Portals Alper Deveci and Metin Dogan 7 7.1 Bony Landmarks Before starting shoulder arthroscopy, the patient must be positioned and draping applied. Then the bony landmarks are identified

More information

SHOULDER PROBLEMS & ARTHROSCOPIC MANAGEMENT

SHOULDER PROBLEMS & ARTHROSCOPIC MANAGEMENT SHOULDER PROBLEMS & ARTHROSCOPIC MANAGEMENT DR.SHEKHAR SRIVASTAV Sr. Consultant-KNEE & SHOULDER Arthroscopy Sant Parmanand Hospital,Delhi Peculiarities of Shoulder Elegant piece of machinery It has the

More information

Operative techniques for treatment of chronic massive rotator cuff lesions : Deltoid flap transfer versus arthroscopic debridement

Operative techniques for treatment of chronic massive rotator cuff lesions : Deltoid flap transfer versus arthroscopic debridement 428 Acta Orthop. Belg., 2017, 83, 428-432 f. blanke, j. sachser, m. majewski ORIGINAL STUDY Operative techniques for treatment of chronic massive rotator cuff lesions : Deltoid flap transfer versus arthroscopic

More information

Conflict of Interest. New Strategies in Rotator Cuff Repair. Objectives. Learner Outcome

Conflict of Interest. New Strategies in Rotator Cuff Repair. Objectives. Learner Outcome Conflict of Interest New Strategies in Rotator Cuff Repair Sheri Lankford, BSN, CNOR I hereby certify that, to the best of my knowledge, no aspect of my current personal or professional situation might

More information

Shoulder Arthroscopy Curriculum

Shoulder Arthroscopy Curriculum ARTHRO Mentor 1 Description All those with an interest in the shoulder should develop a basic level of proficiency and should be able to perform a thorough diagnostic exam, looking from both the anterior

More information

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D. SURGICAL TECHNIQUE ROTATOR CUFF REPAIR BIOKNOTLESSRC SUTURE ANCHOR Surgical Technique for Arthroscopic Rotator Cuff Repair Raymond Thal, M.D. Town Center Orthopaedic Associates Reston, Virginia Surgical

More information

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE ! SURGICAL TECHNIQUE! DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. ARTHROSCOPIC AND SUBPECTORAL BICEPS TENODESIS SURGICAL TECHNIQUE BICEPS TENODESIS Indications Tenodesis of

More information

D Degenerative joint disease, rotator cuff deficiency with, 149 Deltopectoral approach component removal with, 128

D Degenerative joint disease, rotator cuff deficiency with, 149 Deltopectoral approach component removal with, 128 Index A Abduction exercise, outpatient with, 193, 194 Acromioclavicular arthritis, with, 80 Acromiohumeral articulation, with, 149 Acromio-humeral interval (AHI), physical examination with, 9, 10 Active

More information

Massive cuff tears treated with arthroscopically assisted latissimus dorsi transfer. Surgical technique

Massive cuff tears treated with arthroscopically assisted latissimus dorsi transfer. Surgical technique Original article Massive cuff tears treated with arthroscopically assisted latissimus dorsi transfer. Surgical technique Vincenzo De Cupis 1, Mauro De Cupis 2 1 I.C.O.T., Latina, Italy 2 Department of

More information

SHOULDER ARTHROPLASTY (TOTAL, HEMI, REVERSE)/ARTHRODESIS

SHOULDER ARTHROPLASTY (TOTAL, HEMI, REVERSE)/ARTHRODESIS evicore healthcare. Clinical Decision Support Tool Diagnostic Strategies This tool addresses common symptoms and symptom complexes. Imaging requests for patients with atypical symptoms or clinical presentations

More information

FUNCTIONAL ANATOMY OF SHOULDER JOINT

FUNCTIONAL ANATOMY OF SHOULDER JOINT FUNCTIONAL ANATOMY OF SHOULDER JOINT ARTICULATION Articulation is between: The rounded head of the Glenoid cavity humerus and The shallow, pear-shaped glenoid cavity of the scapula. 2 The articular surfaces

More information

Biomechanical concepts of total shoulder replacement. «Shoulder Course» Day 1. Richard W. Nyffeler Orthopädie Sonnenhof Bern. 11. Sept.

Biomechanical concepts of total shoulder replacement. «Shoulder Course» Day 1. Richard W. Nyffeler Orthopädie Sonnenhof Bern. 11. Sept. Biomechanical concepts of total shoulder replacement Richard W. Nyffeler Orthopädie Sonnenhof Bern First total shoulder prosthesis Jules Emile Péan, 1830-1898 Monobloc prostheses Charles Neer, 1917-2011

More information

STATE OF CONNECTICUT ETHICS BOARD NONE ARTHREX INC ARTHREX INC

STATE OF CONNECTICUT ETHICS BOARD NONE ARTHREX INC ARTHREX INC Rationale, Biomechanics,Early Results after Superior Capsular Reconstruction Augustus D Mazzocca MS, MD Director of the New England Musculoskeletal Institute Chairman Department of Orthopaedic Surgery

More information

BICEPTOR Tenodesis System

BICEPTOR Tenodesis System BICEPTOR Tenodesis System Sub-Pectoral Biceps Tenodesis A Shoulder Series Technique Guide As described by: Nikhil N. Verma, MD As described by: Nikhil N. Verma, MD Midwest Orthopedics at Rush Chicago,

More information

Cigna Medical Coverage Policies Musculoskeletal Shoulder Arthroplasty (Total, Hemi, Reverse)/Arthrodesis

Cigna Medical Coverage Policies Musculoskeletal Shoulder Arthroplasty (Total, Hemi, Reverse)/Arthrodesis Cigna Medical Coverage Policies Musculoskeletal Shoulder Arthroplasty (Total, Hemi, Reverse)/Arthrodesis Effective January 1, 2016 Instructions for use The following coverage policy applies to health benefit

More information

SSSR. 1. Nov Shoulder Prosthesis. Postoperative Imaging. Florian M. Buck, MD

SSSR. 1. Nov Shoulder Prosthesis. Postoperative Imaging. Florian M. Buck, MD Shoulder Prosthesis Postoperative Imaging Florian M. Buck, MD Shoulder Prosthesis Surgical Approach Findings Imaging Modalities Postoperative Problems Shoulder Prosthesis What are we talking about Anatomical

More information

Surgical management of massive rotator cuff tears

Surgical management of massive rotator cuff tears All-Arthroscopic Patch Augmentation of a Massive Rotator Cuff Tear: Surgical Technique Peter N. Chalmers, M.D., Rachel M. Frank, M.D., Anil K. Gupta, M.D., M.B.A., Adam B. Yanke, M.D., Scott W. Trenhaile,

More information

Short term results of arthroscopic repair of subscapularis tendon tear

Short term results of arthroscopic repair of subscapularis tendon tear Original Research Medical Journal of the Islamic Republic of Iran.Vol. 23, No. 3, November, 2009. pp. 117-121 Short term results of arthroscopic repair of subscapularis tendon tear Hamid Reza Aslani, MD.

More information

The Current State of Rotator Cuff Repairs

The Current State of Rotator Cuff Repairs Conflict of Interest Slide The Current State of Rotator Cuff Repairs Gerald R. Williams, Jr, MD John M. Fenlin, Jr, MD Professor of Shoulder and Elbow Surgery Royalties Depuy: shoulder arthroplasty DJO:

More information

Augmented Glenoid Component for Bone Deficiency in Shoulder Arthroplasty

Augmented Glenoid Component for Bone Deficiency in Shoulder Arthroplasty Clin Orthop Relat Res (2008) 466:579 583 DOI 10.1007/s11999-007-0104-4 SYMPOSIUM: NEW APPROACHES TO SHOULDER SURGERY Augmented Glenoid Component for Bone Deficiency in Shoulder Arthroplasty Robert S. Rice

More information

Shoulder Anatomy and a preface on the Shoulder Arthroscopy.

Shoulder Anatomy and a preface on the Shoulder Arthroscopy. Shoulder Anatomy and a preface on the Shoulder Arthroscopy www.fisiokinesiterapia.biz Shoulder Anatomy Shoulder Anatomy Greatest ROM No inherent bony stability Relies on soft tissues for stability Many

More information

Common Surgical Shoulder Injury Repairs

Common Surgical Shoulder Injury Repairs Common Surgical Shoulder Injury Repairs Mr Ilia Elkinson BHB, MBChB, FRACS (Ortho), FNZOA Orthopaedic and Upper Limb Surgeon Bowen Hospital Wellington Hospital Objectives Review pertinent anatomy of the

More information

Dual Row Rotator Cuff Repair using the CHIA PERCPASSER

Dual Row Rotator Cuff Repair using the CHIA PERCPASSER Dual Row Rotator Cuff Repair using the CHIA PERCPASSER THOMAS P. KNAPP, M.D. Santa Monica Orthopaedic & Sports Medicine Group TM CHIA PERCPASSER Surgical Technique Dual Row Rotator Cuff Repair using the

More information

Arthroscopy / MRI Correlation Conference. Department of Radiology, Section of MSK Imaging Department of Orthopedic Surgery 7/19/16

Arthroscopy / MRI Correlation Conference. Department of Radiology, Section of MSK Imaging Department of Orthopedic Surgery 7/19/16 Arthroscopy / MRI Correlation Conference Department of Radiology, Section of MSK Imaging Department of Orthopedic Surgery 7/19/16 Case 1: 29 YOM with recurrent shoulder dislocations Glenoid Axial T1FS

More information

US finding of the shoulder (with live demonstration) 인제의대상계백병원 안재기

US finding of the shoulder (with live demonstration) 인제의대상계백병원 안재기 US finding of the shoulder (with live demonstration) 인제의대상계백병원 안재기 Shoulder US Biceps tendon & Rotator Cuff Long Head of Biceps Tendon Subscapularis tendon Supraspinatus tendon Infraspinatus tendon Teres

More information

The Shoulder. By Patrick Ryan, Bobby Law, Jack Beaty, Alex Newhouse and Chuck Nelson

The Shoulder. By Patrick Ryan, Bobby Law, Jack Beaty, Alex Newhouse and Chuck Nelson The Shoulder By Patrick Ryan, Bobby Law, Jack Beaty, Alex Newhouse and Chuck Nelson Learning Objectives/Agenda Review the anatomy of the shoulder Describe the main diseases of the shoulder Describe the

More information

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique It s small. It s strong. And it's all suture. The JuggerKnot Soft Anchor represents the next generation of suture anchor technology.

More information

11/15/2017. Biceps Lesions. Highgate Private Hospital (Whittington Health NHS Trust) E: LHB Anatomy.

11/15/2017. Biceps Lesions. Highgate Private Hospital (Whittington Health NHS Trust) E: LHB Anatomy. Biceps Lesions Mr Omar Haddo (Consultant Orthopaedic Surgeon MBBS, BmedSci, FRCS(Orth) ) Highgate Private Hospital (Whittington Health NHS Trust) E: admin@denovomedic.co.uk LHB Anatomy Arise from superior

More information

Latissimus dorsi transfer for primary treatment of irreparable rotator cuff tears

Latissimus dorsi transfer for primary treatment of irreparable rotator cuff tears J Orthopaed Traumatol (2002) 2:139 145 Springer-Verlag 2002 ORIGINAL F. Postacchini S. Gumina P. De Santis R. Di Virgilio Latissimus dorsi transfer for primary treatment of irreparable rotator cuff tears

More information

How they begin 8/18/15. Arthroscopic Management of Complex RCT. Disclosures in AAOS Database

How they begin 8/18/15. Arthroscopic Management of Complex RCT. Disclosures in AAOS Database Arthroscopic Management of Complex RCT Brian J. Cole, MD, MBA Professor and Vice-Chairman, Department of Orthopedics Chairman, Department of Surgery, Rush OPH Team Physician, Chicago Whites Sox and Bulls

More information

Gregory P. Nicholson, M.D. Disclosures. Indications for Open RCR. Open RC Repairs 2015 and Role of Tendon Transfers. Associate Professor

Gregory P. Nicholson, M.D. Disclosures. Indications for Open RCR. Open RC Repairs 2015 and Role of Tendon Transfers. Associate Professor Open RC Repairs 2015 and Role of Tendon Transfers Gregory P. Nicholson, M.D. Associate Professor Rush University Medical Center Chicago, Illinois Disclosures Research and Educational Support: Tornier,

More information

Fully Torn Rotator Cuff Repair

Fully Torn Rotator Cuff Repair Fully Torn Rotator Cuff Repair A torn rotator cuff is a common condition that can cause shoulder pain, weakness, and loss of mobility. If the tear is severe enough, surgical intervention is often necessary

More information

R. Frank Henn III, MD. Associate Professor Chief of Sports Medicine Residency Program Director

R. Frank Henn III, MD. Associate Professor Chief of Sports Medicine Residency Program Director R. Frank Henn III, MD Associate Professor Chief of Sports Medicine Residency Program Director Disclosures No financial relationships to disclose 1. Labral anatomy 2. Adaptations of the throwing shoulder

More information

Reverse Total Shoulder Arthroplasty Protocol Shawn Hennigan, MD

Reverse Total Shoulder Arthroplasty Protocol Shawn Hennigan, MD General Information: Reverse Total Shoulder Arthroplasty Protocol Shawn Hennigan, MD Reverse or Inverse Total Shoulder Arthroplasty (rtsa) is designed specifically for the treatment of glenohumeral (GH)

More information

Rotator Cuff Tears: Surgical Treatment Options

Rotator Cuff Tears: Surgical Treatment Options Rotator Cuff Tears: Surgical Treatment Options The following article provides in depth information about surgical treatment for rotator cuff injuries, and is a continuation of the article "Rotator Cuff

More information

ROTATOR CUFF INJURIES / IMPINGEMENT SYNDROME

ROTATOR CUFF INJURIES / IMPINGEMENT SYNDROME ROTATOR CUFF INJURIES / IMPINGEMENT SYNDROME Shoulder injuries are common in patients across all ages, from young, athletic people to the aging population. Two of the most common problems occur in the

More information

Massive Rotator Cuff Tears Pathophysiology and Treatment Options. Mike Walton Consultant Shoulder Surgeon Wrightington Hospital

Massive Rotator Cuff Tears Pathophysiology and Treatment Options. Mike Walton Consultant Shoulder Surgeon Wrightington Hospital Massive Rotator Cuff Tears Pathophysiology and Treatment Options Mike Walton Consultant Shoulder Surgeon Wrightington Hospital Tendon Structure Tendons are mechanically responsible for the transmission

More information

Rehabilitation Guidelines for Labral/Bankert Repair

Rehabilitation Guidelines for Labral/Bankert Repair Rehabilitation Guidelines for Labral/Bankert Repair The true shoulder joint is called the glenohumeral joint and consists humeral head and the glenoid. It is a ball and socket joint. Anatomy of the Shoulder

More information

Vol 3, 2008 CEC ARTICLE: Special Medical Conditions Part 2: Shoulder Maintenance and Rehab C. Eggers

Vol 3, 2008 CEC ARTICLE: Special Medical Conditions Part 2: Shoulder Maintenance and Rehab C. Eggers Vol 3, 2008 CEC ARTICLE: Special Medical Conditions Part 2: Shoulder Maintenance and Rehab C. Eggers SHOULDER GIRDLE STABILIZATION Knowledge of the anatomy and biomechanics of the shoulder girdle is essential

More information

SHOULDER JOINT ANATOMY AND KINESIOLOGY

SHOULDER JOINT ANATOMY AND KINESIOLOGY SHOULDER JOINT ANATOMY AND KINESIOLOGY SHOULDER JOINT ANATOMY AND KINESIOLOGY The shoulder joint, also called the glenohumeral joint, consists of the scapula and humerus. The motions of the shoulder joint

More information

Massive Rotator Cuff Tears Arthroscopic Treatments

Massive Rotator Cuff Tears Arthroscopic Treatments Massive Rotator Cuff Tears Arthroscopic Treatments Brian D. Busconi, MD Chief of Sports Medicine & Arthroscopy UMass Memorial Medical Center Brian.Busconi@umassmemorial.org Disclosures Consultant Arthrex

More information

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE INTERVENTIONAL PROCEDURES PROGRAMME Interventional procedure overview of superior capsular augmentation for massive rotator cuff tears The rotator cuff

More information

ARTHROSCOPIC SUPRASCAPULAR NERVE RELEASE

ARTHROSCOPIC SUPRASCAPULAR NERVE RELEASE ARTHROSCOPIC SUPRASCAPULAR NERVE RELEASE Laurent Lafosse & Robert Fullick Alps Surgery Institute Annecy France DISCLOSURE Royalties Depuy Consultant Depuy Stock options ITS Stock options Orthospace 1 Background

More information

A Patient s Guide to Rotator Cuff Tendinitis or Shoulder Impingement

A Patient s Guide to Rotator Cuff Tendinitis or Shoulder Impingement A Patient s Guide to Rotator Cuff Tendinitis or Shoulder Impingement Introduction Shoulder pain is a common condition whether due to aging, overuse, trauma or a sports injury. Shoulder pain and injuries

More information

CiSE. Introduction ORIGINAL ARTICLE. Tae Kang Lim, Kyu Hwan Bae

CiSE. Introduction ORIGINAL ARTICLE. Tae Kang Lim, Kyu Hwan Bae ORIGINAL ARTICLE Vol. 22, No. 1, March, 2019 https://doi.org/10.5397/cise.2019.22.1.9 CiSE Arthroscopic-assisted Latissimus Dorsi Tendon Transfer for the Management of Irreparable Rotator Cuff Tears in

More information

SHOULDER IMPINGEMENT / ROTATOR CUFF TENDONITIS / SUBACROMIAL BURSITIS

SHOULDER IMPINGEMENT / ROTATOR CUFF TENDONITIS / SUBACROMIAL BURSITIS SHOULDER IMPINGEMENT / ROTATOR CUFF TENDONITIS / SUBACROMIAL BURSITIS The terms impingement, rotator cuff tendonitis, and subacromial bursitis, all refer to a spectrum of the same condition. Anatomy The

More information

Shoulder: Clinical Anatomy, Kinematics & Biomechanics

Shoulder: Clinical Anatomy, Kinematics & Biomechanics Shoulder: Clinical Anatomy, Kinematics & Biomechanics Dr. Alex K C Poon Department of Orthopaedics & Traumatology Pamela Youde Nethersole Eastern Hospital Clinical Anatomy the application of anatomy to

More information

Index. ESSKA 2018 G. Milano et al. (eds.), Management of Failed Shoulder Surgery,

Index. ESSKA 2018 G. Milano et al. (eds.), Management of Failed Shoulder Surgery, A Acromial fractures, 186 Acromioclavicular joint (ACJ) instability, 55, 97 case study, 98 100 classification, 85 clinical relevant situations, 86 dislocation, 97 98 insufficient fixation, 87 88 operative

More information

Rehabilitation Guidelines for Shoulder Arthroscopy

Rehabilitation Guidelines for Shoulder Arthroscopy UW HEALTH SPORTS REHABILITATION Rehabilitation Guidelines for Shoulder Arthroscopy Front View Acromion Supraspinatus Back View Supraspinatus Long head of bicep Type I Infraspinatus Short head of bicep

More information

Part II: Rotator Cuff Repair, Day of Surgery and Postoperative Course

Part II: Rotator Cuff Repair, Day of Surgery and Postoperative Course Part II: Rotator Cuff Repair, Day of Surgery and Postoperative Course Benjamin W. Sears, MD 303-321-1333 western-ortho.com denvershoulder.com Day of Surgery Most patients will undergo outpatient surgery

More information

Tendinosis & Subacromial Impingement Syndrome. Gene Desepoli, LMT, D.C.

Tendinosis & Subacromial Impingement Syndrome. Gene Desepoli, LMT, D.C. Tendinosis & Subacromial Impingement Syndrome Gene Desepoli, LMT, D.C. What is the shoulder joint? Shoulder joint or shoulder region? There is an interrelatedness of all moving parts of the shoulder and

More information

ARTHROSCOPIC GIANT NEEDLE ROTATOR CUFF REPAIR AS A ROUTINE PROCEDURE SINCE 1990

ARTHROSCOPIC GIANT NEEDLE ROTATOR CUFF REPAIR AS A ROUTINE PROCEDURE SINCE 1990 ARTHROSCOPIC GIANT NEEDLE ROTATOR CUFF REPAIR AS A ROUTINE PROCEDURE SINCE 1990 A 10 minutes transhumeral footprint repair using only sutures AIG Medical GmbH Bonn (Aeratec) Essential for this surgery

More information

3/9/2018. Algorithm for Massive RCT s. Massive Rotator Cuff Tears: When is Reverse TSA the only option?

3/9/2018. Algorithm for Massive RCT s. Massive Rotator Cuff Tears: When is Reverse TSA the only option? Massive Rotator Cuff Tears: When is Reverse TSA the only option? Anthony A. Romeo, MD Professor, Department of Orthopedics Head, Section of Shoulder and Elbow Surgery Team Physician, Chicago White Sox

More information

Asymptomatic acromioclavicular joint arthritis in arthroscopic rotator cuff tendon repair: a prospective randomized comparison study

Asymptomatic acromioclavicular joint arthritis in arthroscopic rotator cuff tendon repair: a prospective randomized comparison study Arch Orthop Trauma Surg (2011) 131:363 369 DOI 10.1007/s00402-010-1216-y ARTHROSCOPY AND SPORTS MEDICINE Asymptomatic acromioclavicular joint arthritis in arthroscopic rotator cuff tendon repair: a prospective

More information

Clinical Study Infraspinatus/Teres Minor Transfer Biceps In Situ Tenodesis Procedure: Initial Results of a Technique for Massive Cuff Tears

Clinical Study Infraspinatus/Teres Minor Transfer Biceps In Situ Tenodesis Procedure: Initial Results of a Technique for Massive Cuff Tears ISRN Orthopedics Volume 2013, Article ID 646598, 4 pages http://dx.doi.org/10.1155/2013/646598 Clinical Study Infraspinatus/Teres Minor Transfer Biceps In Situ Tenodesis Procedure: Initial Results of a

More information

Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft

Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft Original Article Clinics in Orthopedic Surgery 2017;9:497-505 https://doi.org/10.4055/cios.2017.9.4.497 Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic

More information

Integra. Titan Modular Shoulder System, 2.5

Integra. Titan Modular Shoulder System, 2.5 Titan Modular Shoulder System, 2.5 Limit uncertainty with a shoulder implant system that redefines modularity, addresses multiple indications, and allows for reproducible results. Titan Modular Shoulder

More information

Current Controversies in Shoulder Surgery:

Current Controversies in Shoulder Surgery: Current Controversies in Shoulder Surgery: Shoulder Instability Rotator Cuff Injury and Repair Reverse Shoulder Arthroplasty Brian Feeley, MD UC San Francisco Sports Medicine and Shoulder Surgery Disclosures

More information

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D.

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D. Rotator Cuff Repair Utilizing the ALLthread Suture Anchor by Scott Kuiper, M.D. The Material Difference Biomet Sports Medicine recognizes the benefit of material options. Many times surgeons require different

More information

The Upper Limb II. Anatomy RHS 241 Lecture 11 Dr. Einas Al-Eisa

The Upper Limb II. Anatomy RHS 241 Lecture 11 Dr. Einas Al-Eisa The Upper Limb II Anatomy RHS 241 Lecture 11 Dr. Einas Al-Eisa Sternoclavicular joint Double joint.? Each side separated by intercalating articular disc Grasp the mid-portion of your clavicle on one side

More information

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco Chairmen: Samuel Antuña Emilio Calvo Fernando Marco www..com 2 Index General Information 04 Faculty 05 Scientific Program Thursday October 18th 06 Friday October 19th 10 3 General information Dates October

More information

Suprascapular Nerve: How to identify when it is a problem and what to do? Speaker Disclosure

Suprascapular Nerve: How to identify when it is a problem and what to do? Speaker Disclosure Suprascapular Nerve: How to identify when it is a problem and what to do? Eric C. McCarty, MD Associate Professor Chief of Sports Medicine and Shoulder Surgery University of Colorado School of Medicine

More information

Leeds-Kuff Patch TM. For Rotator Cuff Reinforcement. Surgical Technique Manual

Leeds-Kuff Patch TM. For Rotator Cuff Reinforcement. Surgical Technique Manual Leeds-Kuff Patch TM For Rotator Cuff Reinforcement Surgical Technique Manual 0086 Introduction Leeds-Kuff Patch TM This technique utilizes a non-absorbable polyester patch which is sutured over the torn

More information

SHOULDER PATIENTS. Diagnostic Shoulder Arthroscopy Technique Guide

SHOULDER PATIENTS. Diagnostic Shoulder Arthroscopy Technique Guide SHOULDER PATIENTS Diagnostic Shoulder Arthroscopy Technique Guide mi-eye 2 Indications for Use The mi-eye 2 system is indicated for use in diagnostic and operative arthroscopic and endoscopic procedures

More information

Diagnosis: Significant atrophy of supraspinatus FATTY INFILTRATION AND CUFF ATROPHY

Diagnosis: Significant atrophy of supraspinatus FATTY INFILTRATION AND CUFF ATROPHY Diagnosis Diagnosis: Significant atrophy of supraspinatus FATTY INFILTRATION AND CUFF ATROPHY Degenerative muscular changes associated with rotator cuff tears include fatty infiltration and atrophy. Increased

More information

Anatomy Your shoulder is made up of three bones: your upper arm bone (humerus), your shoulder blade (scapula), and your collarbone (clavicle).

Anatomy Your shoulder is made up of three bones: your upper arm bone (humerus), your shoulder blade (scapula), and your collarbone (clavicle). Shoulder Impingement/Rotator Cuff Tendinitis One of the most common physical complaints is shoulder pain. Your shoulder is made up of several joints combined with tendons and muscles that allow a great

More information

Immediate post surgical findings of soft tissue swelling, subcutaneous emphysema, and skin staples for reverse total shoulder arthroplasty.

Immediate post surgical findings of soft tissue swelling, subcutaneous emphysema, and skin staples for reverse total shoulder arthroplasty. Immediate post surgical findings of soft tissue swelling, subcutaneous emphysema, and skin staples for reverse total shoulder arthroplasty. REVERSE TOTAL SHOULDER ARTHROPLASTY WITH FRACTURED ACROMION Above:

More information

Clinical Outcomes and Complications during the Learning Curve for Reverse Total Shoulder Arthroplasty: An Analysis of the First 40 Cases

Clinical Outcomes and Complications during the Learning Curve for Reverse Total Shoulder Arthroplasty: An Analysis of the First 40 Cases Original Article Clinics in Orthopedic Surgery 2017;9:213-217 https://doi.org/10.4055/cios.2017.9.2.213 Clinical Outcomes and Complications during the Learning Curve for Reverse Total Shoulder Arthroplasty:

More information

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco 2nd Chairmen: Samuel Antuña Emilio Calvo Fernando Marco www..com 2 2nd Index General Information 04 Faculty 05 Scientific Program Thursday October 18th 06 Friday October 19th 10 Traducción simultánea Inglés

More information

PROGRAM THURSDAY APRIL 5, 2018

PROGRAM THURSDAY APRIL 5, 2018 PROGRAM THURSDAY APRIL 5, 2018 Welcome Hot And Controversial Topics Anterior Shoulder Instability Invited Special Guest Lecture 07:00 Registration 07:45-08:00 Welcome 07:45 Why are we here? Scheibel Session

More information

The Shoulder. Systematically scanning the shoulder provides extremely useful diagnostic information. The Shoulder

The Shoulder. Systematically scanning the shoulder provides extremely useful diagnostic information. The Shoulder 1 ! The most ACCESSIBLE to sonographic exam! The most MOBILE and VULNERABLE extremity AND Systematically scanning the shoulder provides extremely useful diagnostic information! The Goal for this section

More information

Rehabilitation Guidelines for Shoulder Arthroscopy

Rehabilitation Guidelines for Shoulder Arthroscopy Rehabilitation Guidelines for Shoulder Arthroscopy The true shoulder joint is called the glenohumeral joint and consists humeral head and the glenoid. It is a ball and socket joint. Anatomy of the Shoulder

More information

Shoulder Ultrasonography as a Diagnostic Tool for Rotator Cuff Disease

Shoulder Ultrasonography as a Diagnostic Tool for Rotator Cuff Disease Shoulder Ultrasonography as a Diagnostic Tool for Rotator Cuff Disease Jay D Keener, MD Associate Professor Shoulder and Elbow Service Washington University Disclosure No relevant financial disclosures

More information

How repaired rotator cuff function influences Constant scoring

How repaired rotator cuff function influences Constant scoring Orthopaedics & Traumatology: Surgery & Research (2010) 96, 500 505 ORIGINAL ARTICLE How repaired rotator cuff function influences Constant scoring D. Goutallier a,, J.-M. Postel a, C. Radier b, J. Bernageau

More information

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco

2nd madrid. shoulder course. msc. MADRID - October 18-19, Chairmen: Samuel Antuña Emilio Calvo Fernando Marco 2nd Chairmen: Samuel Antuña Emilio Calvo Fernando Marco www..com 2nd 2 2nd INDEX General Information 04 Faculty 05 Program at a Glance 06 Scientific Program Thursday October 18th 08 Friday October 19th

More information

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair Surgical Technique by Shabi Kahn, MD One Surgeon. One Patient. Over 1 million times per year, Biomet

More information

Rotator Cuff Repair Outcomes. Patrick Birmingham, MD

Rotator Cuff Repair Outcomes. Patrick Birmingham, MD Rotator Cuff Repair Outcomes Patrick Birmingham, MD Outline Arthroscopic Vs. Mini-open Subjective Outcomes Objective Outcomes Timing Arthroscopic Vs. Mini-open Sauerbrey Arthroscopy 2005 Twenty-six patients

More information

WHAT YOU IS BACK WITHIN ARM S REACH

WHAT YOU IS BACK WITHIN ARM S REACH YOUR TOTAL SHOULDER REPLACEMENT SURGERY STEPS TO RETURNING TO A LIFESTYLE YOU DESERVE WHAT YOU IS BACK WITHIN ARM S REACH Nathan Richardson, MD Orthopedics, Shoulder & Elbow Surgeon Board Certified in

More information

Rotator Cuff Repair TRENDS OF REPAIRS. Evolution of Arthroscopic Repair. Shoulder Girdle. Rotator Cuff Repair 8/29/2013

Rotator Cuff Repair TRENDS OF REPAIRS. Evolution of Arthroscopic Repair. Shoulder Girdle. Rotator Cuff Repair 8/29/2013 Rotator Cuff Repair Indications, Patient Selection, Outcomes James C. Vailas, M.D. New Hampshire Orthopaedic Center September 14, 2013 New Hampshire Musculoskeletal Institute 20 th Annual Symposium Evolution

More information

Technique. Aequalis Resurfacing Humeral Head

Technique. Aequalis Resurfacing Humeral Head S u r g i c a l Technique Aequalis Resurfacing Humeral Head 1 The Aequalis Resurfacing Humeral Head has been developed in conjunction with Drew Miller, MD - Atlanta, GA. The Aequalis Resurfacing Humeral

More information

Degenerative joint disease of the shoulder, while

Degenerative joint disease of the shoulder, while Arthroscopic Debridement of the Shoulder for Osteoarthritis David M. Weinstein, M.D., John S. Bucchieri, M.D., Roger G. Pollock, M.D., Evan L. Flatow, M.D., and Louis U. Bigliani, M.D. Summary: Twenty-five

More information

Evaluation of Rotator Cuff Repair Using Korean Shoulder Scoring System

Evaluation of Rotator Cuff Repair Using Korean Shoulder Scoring System ORIGINAL ARTICLE Clinics in Shoulder and Elbow Vol. 18, No. 4, December, 2015 http://dx.doi.org/10.5397/cise.2015.18.4.206 CiSE Clinics in Shoulder and Elbow Evaluation of Rotator Cuff Repair Using Korean

More information