Detection of Immunoglobulin M Antibodies Specific for Toxoplasma gondii with Increased Selectivity for Recently Acquired Infections

Size: px
Start display at page:

Download "Detection of Immunoglobulin M Antibodies Specific for Toxoplasma gondii with Increased Selectivity for Recently Acquired Infections"

Transcription

1 JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 2004, p Vol. 42, No /04/$ DOI: /JCM Copyright 2004, American Society for Microbiology. All Rights Reserved. Detection of Immunoglobulin M Antibodies Specific for Toxoplasma gondii with Increased Selectivity for Recently Acquired Infections Ravi Kaul,* Peilin Chen, and Steven R. Binder Clinical Diagnostics Group, Bio-Rad Laboratories, Hercules, California Received 12 April 2004/Returned for modification 26 July 2004/Accepted 26 August 2004 Toxoplasma gondii infections can cause serious complications in pregnant women, leading to miscarriage, stillbirth, and birth defects. Definitive diagnosis of T. gondii acute infection is therefore critical for the clinical management of a mother and her fetus. Positive immunoglobulin M () results are not sufficient as evidence of recent infection, as these antibodies are often present for many months. Further, IgG avidity and differential agglutination tests, two tests used by reference laboratories to distinguish between recent and past infections, are not always in agreement, and both methods yield a significant number of indeterminate results. We report the development of a new immunoassay that is performed by using a bead-based immunoassay on an automated analyzer (BioPlex 2200). Initial validation included 204 samples from pregnant women and 198 samples from asymptomatic healthy adults. An overall specificity of 99% was observed. Further, 100% sensitivity for acute infections was observed for 10 well-characterized seroconversion panels. We then examined 50 samples from pregnant women, all of which were positive by ELISA, which had been fully evaluated in a reference laboratory. Of the 50 samples, 34 (68%) tested positive in the BioPlex 2200 assay, of which 32 of 34 (94%) exhibited an acute or equivocal pattern by differential agglutination. Of the 16 negative samples, 15 (94%) showed high-igg-avidity antibodies. Collectively, these results suggest that this new assay shows a preferential response to antibodies produced by recent infections, reducing the number of positive results for pregnant women that will require extensive additional clinical evaluation. Toxoplasma gondii is an obligate intracellular protozoan responsible for common parasitic infections throughout the world. It affects a wide range of hosts, including humans, domestic mammals, and birds, with members of the cat family being the only known hosts for the sexual stages of T. gondii infection. In general, T. gondii infections are asymptomatic and self-limiting, especially among healthy immunocompetent hosts; however, the infection may cause severe complications in pregnant women and immunocompromised patients (6). Fetal infection can develop only when a woman with no immunity becomes infected with T. gondii during pregnancy or up to 8 weeks before conceiving. Fetal toxoplasmosis, particularly in early pregnancy, can cause miscarriage, stillbirth, and birth defects. Infected babies may not develop any disease, or they may experience serious damage to the brain and eyes. The detection of recently acquired infection in pregnant women is therefore critical for clinical management of the mother and her fetus (19, 20, 23, 25). PCR amplification of T. gondii DNA in blood cells, body fluids, and tissues has been used successfully for the diagnosis of congenital toxoplasmosis; however, its reliability with amniotic fluid samples before 18 weeks of gestational age is unknown (5, 21). Furthermore, PCR amplification is not very helpful in predicting the time of infection, because the clearance of DNA from body fluids and tissue samples is not well established. The detection of T. gondii-specific immunoglobulin M () antibodies is the most common method used to determine the point during pregnancy when the infection occurred. In the * Corresponding author. Mailing address: Clinical Diagnostic Group, 4000 Alfred Nobel Dr., Hercules, CA Phone: (510) Fax: (510) ravi_kaul@bio-rad.com. United States, the incidence of acute infection during pregnancy has been estimated to be approximately 0.2 to 1.0%, although in about 90% of cases the disease goes unrecognized (25). In some countries, the seroprevalence of antibodies has been reported to be as high as 2.4% (23). Identifying the time of primary infection is crucial for the clinical management of pregnant women because of an inverse correlation between the severity of toxoplasmosis for the fetus and the gestational age (14, 25). However, variability among in vitro commercial kits prompted the United States Food and Drug Administration (FDA) to reexamine the performance of these kits in 1997 (24). The clinical specificity of these kits varied between 77 and 99% compared to the reference enzyme-linked immunosorbent assay (ELISA) test (17). For this reason, the FDA currently requires additional evaluation of preliminary positive results by a reference laboratory. Repeat testing of is not sufficient to confirm acute infection because antibodies may persist for months or even years after acute infection (1, 4, 15). In an evaluation of -positive sera from pregnant women, submitted by clinical laboratories using FDA-cleared tests, 60% of the sera were determined to be consistent with chronic (nonacute) infection when tested by the U.S. reference laboratory for T. gondii antibodies at the Research Institute, Palo Alto Medical Foundation (PAMF), Palo Alto, Calif. (13). This reference laboratory uses a serum profile that includes a double sandwich ELISA (17), a differential agglutination test (AC/HS test) (2), and the Sabin-Feldman dye test (22) in combination with IgG avidity results (8, 11, 12, 16) to distinguish between recently acquired and distant infections. A positive and IgG test with a high IgG avidity test during the first trimester rules out acute infection in women, but the 5705

2 5706 KAUL ET AL. J. CLIN. MICROBIOL. presence of low-avidity IgG antibody does not rule out a nonacute infection (15). In this situation, the results from the additional methods are carefully considered. Because no avidity or differential agglutination test has been cleared by the FDA, such tests are performed only at reference laboratories and require carefully trained personnel for proper reading and interpretation of results. Outside of the U.S., a few avidity tests are commercially distributed. This report describes the development of a new immunoassay that utilizes the Bio-Rad BioPlex 2200 immunoassay analyzer, a fully automated platform with multiplex capabilities (10). The data demonstrate that the conditions employed for the immunoassay yielded a differential response to T. gondii-specific antibodies, with reduced sensitivity to from samples with high-avidity IgG antibodies. This selective response may reduce the number of -positive specimens from women with nonacute infection, reducing the number of patients requiring clinical management. MATERIALS AND METHODS T. gondii antigen. The T. gondii antigenic extract from Viral Antigens (Memphis, Tenn.) was reextracted with high-salt carbonate buffer (1 M sodium chloride in 150 mm sodium carbonate buffer, ph 9.0) for 30 min at room temperature; the purified cell extract was suspended in 10 mm phosphate-buffered saline for subsequent use in the BioPlex 2200 immunoassay. Western blot analyses that were performed on unprocessed and partially purified extracts showed similar antigenic profiles, supporting the observation that antigenic integrity is maintained during the purification process (data not shown). Serum specimens. Sera from 402 subjects procured from two blood banks were used in this study. The samples included two populations: asymptomatic healthy donors born between the years 1933 and 1994 (n 198) and pregnant women (n 204). Of the serum samples from pregnant women, 100 samples were drawn from women in their first trimester, 100 samples were drawn from women in the second trimester, and 4 samples were drawn from women in the third trimester. In addition, nonconsecutive, well-characterized -positive samples from 25 pregnant women after 16 weeks of gestation and another 25 samples from women after 16 weeks of gestation were supplied by the PAMF. Also, 10 seroconversion panels that were provided by the Hospital La Timone, Marseilles, France, were included in this study. Each seroconversion panel represented three or more sequential serum samples from subjects who were initially IgG and negative for antibodies and then seroconverted in response to acute infection. Reference assays. The results from the BioPlex 2200 multianalyte immunoassay analyzer were compared to those obtained with several commercially available kits. For specificity, samples were analyzed with the PlateliaToxo (Bio-Rad Laboratories Diagnostic Group, Redmond, Wash.). For seroconversion, samples were analyzed by using biomerieux (Hazelwood, Mo.) avidity VIDAS and ISAGA kits and the Roche Cobas Core IgG kit. Finally, serum profiles were generated at the PAMF by using the BioMerieux IgG avidity test (16) as well as the in-house double sandwich ELISA (17), the differential agglutination (AC/HS) test (2), and the Sabin-Feldman dye test (22). Six samples that tested positive by the Platelia and BioPlex 2200 assays were reevaluated at the PAMF by using their in-house ELISA, AC/HS test, and IgG avidity test. BioPlex 2200 immunoassay analyzer. The BioPlex 2200 (Bio-Rad Laboratories Diagnostic Group, Hercules, Calif.) is a fully automated, floor-standing random access platform with multiplex capabilities. The instrument combines the Luminex (Austin, Tex.) multianalyte profiling (Lab-MAP) technology (3) with unique antigen-coated fluoromagnetic bead chemistry and versatile software. The bead reagent was prepared via a three-step procedure involving (i) chemical activation of carboxyl groups on 8- m-diameter fluoromagnetic polystyrene beads, (ii) covalent coupling of antigen, and (iii) blocking of the unreacted sites with 2% bovine serum albumin (BSA). Essentially, the carboxylic acid groups on the surfaces of fluoromagnetic beads were activated in the presence of N-(3-dimethylaminopropyl)-N -ethylcarbodiimide and N-hydroxysuccinimide to form activated esters. These esters react with amino groups on purified antigen, yielding stable amide bonds. Following coupling, beads were blocked with 10 mm phosphate buffer, ph 7.4, containing 150 mm sodium TABLE 1. Comparison of T. gondii-specific response for seroconversion panels using different assay formats a Group biomerieux VIDAS biomerieux ISAGA chloride and 2% BSA for 2 h at room temperature. Blocked beads were washed three times with bead storage buffer (50 mm Tris-HCl, ph 8.1, 150 mm sodium chloride, and 2% BSA) and stored at 4 C. The amount of antigen coated on beads was titrated for optimal performance. Buffered solution (100 l) containing the antigen-coupled fluoromagnetic beads was mixed with 5 l of serum sample and 100 l of sample treatment buffer, which contained goat anti-human IgG. The mixture was incubated for 20 min at 37 C, followed by two washes. Subsequently, beads were incubated with 50 l ofanr-phycoerythrin-conjugated goat anti-human reagent (Jackson ImmunoResearch, West Grove, Pa.) for 10 min at 37 C, washed twice, and aspirated into the Luminex detector module. The median relative fluorescent intensity of the beads were measured and recorded. The median relative fluorescent intensity values were converted into an antibody index (AI) by using a 5-point calibration curve created by serially diluting pooled high-titer samples with a pool of -negative blood bank samples. Cutoffs for the BioPlex 2200 assay were adjusted to maximize both assay sensitivity and specificity against the Platelia kit. All samples with an AI value of 1.0 were considered positive, while samples with an AI value of 1.0 were treated as negative. Each test includes three internal quality control bead controls designed to monitor detector stability, specimen and sample integrity, and the presence of nonspecific binding that could result in inaccurate serology assays. RESULTS BioPlex 2200 Roche Cobas Core IgG Positive 31 b Negative a Ten different seroconversion panels comprising a total of 44 samples were evaluated. The seronegativity for both and IgG of the first (and sometimes second) sample from each panel is reflective of its preconversion status. b One equivocal result was scored as positive. Seroconversion panels serve as valuable tools for evaluating the clinical sensitivity of an immunoassay, since the positive samples are known to result from an acute infection. A total of 44 serum samples derived from 10 seroconversion panels were tested to evaluate the performance of the BioPlex 2200 assay. Table 1 compares the BioPlex 2200 test results with biomerieux VIDAS and biomerieux ISAGA assay results and the Roche Cobas Core IgG results provided by the Hospital La Timone. The IgG levels were measured to document that each patient was initially seronegative. One hundred percent agreement between the biomerieux Vidas and BioPlex 2200 test results was observed for all 10 seroconversion panels. One serum sample with an equivocal AI value of 0.6 by the biomerieux Vidas test was scored as positive. None of the samples reverted to seronegative status, even though the follow-up samples were drawn long after seroconversion (median, 62 days; range, 22 to 247 days). For two of the seroconversion panels, antibodies were detected before IgG antibodies, which accounted for the three additional negative IgG results. The specificity of the BioPlex 2200 immunoassay was evaluated for 402 retrospectively collected samples. Table 2 lists the serological test results for these samples. None of the 198 asymptomatic healthy donors tested positive by either the BioPlex 2200 or the Platelia assay. In comparison, a positivity rate of 1.5%

3 VOL. 42, 2004 BioPlex 2200 TOXOPLASMA IMMUNOASSAY 5707 TABLE 2. Comparison of the specificity of the Platelia and BioPlex 2200 test results for 402 serum samples Group Number (n) Platelia BioPlex 2200 Positive Negative Positive Negative Healthy donors Pregnant women a a 201 Total (% positive) (0.7%) (0.7%) 399 a While the number of positive samples identified by the Platelia and BioPlex 2200 assays among pregnant women was the same, the two assays identified different samples as positive. All of the positive results had signals that were less than 1.5 times the cutoff. The reference laboratory results for these six positive samples were negative, and hence these samples were designated as false positives. (3 of 204) was observed among pregnant-donor samples when tested by either the Platelia or the BioPlex 2200 immunoassay. The three samples that tested positive by the Platelia assay were negative by the BioPlex 2200 assay, and the three samples that tested positive by the BioPlex 2200 assay were negative in the Platelia assay. Repeat tests on these six discrepant samples did not alter the results. Subsequently, these six samples were reevaluated at the reference laboratory for, AC/HS differential agglutination, and IgG avidity. All six samples were negative for, with a nonacute AC/HS pattern. Furthermore, two of six samples showed highavidity IgG antibodies. The performance of the BioPlex 2200 assay for pregnant women with suspected primary infections was evaluated by comparing the results with the serology profile performed at the Research Institute, PAMF. A total of 50 samples from pregnant women were fully characterized; half were collected at 16 weeks of gestation and the other half at 16 weeks of gestation. All 50 samples were positive for by the PAMF ELISA. Forty-four of the 50 positive samples (88%) had either an acute or an equivocal AC/HS pattern, and 6 had a nonacute pattern (Table 3). Only 28 of 50 (56%) of the positive samples had high-iggavidity antibodies, which essentially rule out recent infection. These included all 6 samples with the nonacute AC/HS pattern and 18 of 20 of the samples with an equivocal AC/HS pattern. Thus, these two confirmatory methods were generally in agreement; only four samples with high avidity had an acute AC/HS pattern. Using the BioPlex 2200, 34 of 50 of the PAMF samples were positive. For the 16 BioPlex negative samples, TABLE 3. Comparison of the AC/HS and VIDAS avidity test results for 50 samples from pregnant women VIDAS avidity test results Acute (n 24) AC/HS pattern (n 50) a Equivocal (n 20) Nonacute (n 6) Low 16 (15) 2 (2) 0 Equivocal 4 (4) 0 0 High 4 (2) 18 (9) 6 (2) a The numbers in parentheses refer to BioPlex positive samples among the corresponding groups. The AC/HS test uses methanol or acetone-fixed and formalin-fixed tachyzoite preparations that express antigenic determinants found early following acute infection (AC antigen) or in the later stages of infection (HS antigen), respectively. 15 (94%) exhibited high IgG avidity results (Fig. 1). Furthermore, 32 of 34 BioPlex -positive samples had either an acute or an equivocal AC/HS pattern, representing 94% agreement (Table 3). In summary, specimens that were positive by the PAMF test and negative by the BioPlex toxoplasmosis test were in 15 of 16 cases associated with nonacute infection, representing more than half of the highavidity samples in this study. When used as a screening test, the BioPlex method might significantly reduce the number of positive specimens that would require additional testing and ultimately be judged inconsistent with acute infection. DISCUSSION There is an urgent need for a test that can determine the true nature of infection given the long half-life of some antibodies (1, 4, 12). Although several test kits are commercially available in the United States and Europe for the diagnosis of T. gondii infections, their results are less than optimal, leading to misdiagnosis and unnecessary treatment of the patient and/or termination of the pregnancy (24). An overall specificity of 99.3% was observed among healthy donor and pregnant donor samples in the present study. In the United States, the incidence of acute infection during pregnancy has been estimated to be approximately 0.2 to 1.0%, although in 90% of cases it goes unrecognized. An evaluation of six commercial kits for the detection of human antibodies to using serology laboratory results as the gold standard scored the Centers for Disease Control and Prevention assay at 99.1% specificity, with other kit performances between 77.5 and 98.6% (24). Newer serological tests that help to discriminate between recent and distant infection, including the differential hemagglutination AC/HS test and avidity of IgG antibodies, have been introduced. While these tests are not FDA cleared for commercial use in the United States, such tests are recommended for all -seropositive patients and are performed by the Research Institute, PAMF, a reference laboratory. However, these tests show a high number of equivocal results, which often lead to repeat testing (12). Approximately 32% (11 of 34) of the BioPlex -positive samples tested equivocal in the AC/HS test, and 12% (4 of 34) were equivocal in the IgG avidity test. Comparison of IgG avidity test results between the PAMF ELISA and the BioPlex positive samples reflects a higher percentage of high-avidity samples (56%) among PAMF ELISA -positive samples than among BioPlex -positive samples (38%; 13 of 34). However, such an anomaly is mainly due to the fact that 15 of 16 -negative samples had high-iggavidity antibodies and hence were excluded from the initial calculation. Collectively, these results are in agreement with the published study showing higher prevalence of high-iggavidity antibodies among ELISA positive samples obtained during the first trimester (12). Additional evidence showing the efficacy of the BioPlex assay was demonstrated by the fact that over 70% of -positive samples exhibited an acute AC/HS pattern after the high-avidity samples were excluded. A similar observation was made with the PAMF ELISA positive samples as well. One explanation for the selective characteristics of the Bio-

4 5708 KAUL ET AL. J. CLIN. MICROBIOL. FIG. 1. Correlation of test results obtained by the BioPlex 2200 assay and the VIDAS IgG avidity assay for 50 pregnant women. The solid vertical lines indicate VIDAS threshold levels for low, equivocal, and high avidity, with test results of 0.2 representing low avidity, results from 0.2 to 0.3 representing equivocal avidity, and results of 0.3 representing high avidity. The solid horizontal line indicates the threshold for discrimination of -negative from -positive samples by the BioPlex 2200 assay. AI values that were 1.0 are scored as positive. Plex 2200 assay is a difference in performance due to the unique characteristics of a particular antigen (15). A study of several recombinant antigens using IgG ELISA demonstrated small differences in reactivity towards sera representing recently acquired and chronic infections (18). However, no recombinants were used in our study. Further, preliminary experiments with natural antigens from multiple sources, including harvested tachyzoites prepared in-house, did not show any change in this selective behavior. Choice of the appropriate antigen, purification of the antigen, and loading of the antigen on the solid phase all influenced specificity towards nonreactive samples but did not influence the selective lack of response to samples that were positive by ELISA methods. Therefore, the selective behavior may be characteristic of the assay format rather than a characteristic of the antigen. Under the conditions employed, the quantity of antigen used in the BioPlex 2200 assay is 10% of the quantity used for ELISA plates, and the incubation time is short. It is possible, therefore, that the selective response reflects differences in the affinity of the different antibodies under the test condition. The Bio-Rad BioPlex 2200 assay offers several advantages over other ELISA methods because it is a rapid, accurate, high-throughput assay with the potential for multiplexed analyses. The use of multiplexed immunoassays, based on flow cytometry, has become routine for the measurement of cytokine levels (9). In a review published in The Lancet in 2002, Jani et al. proposed that such technology could be useful for the diagnosis and surveillance of infectious diseases, even in a resource-poor setting (7). Similarly, the method for detecting described here could be combined with additional methods for detecting rubella, cytomegalovirus, and herpes to facilitate maternal screening; a matching profile of IgG antibody is also possible. The reduced sensitivity to from samples with high-avidity IgG may lead to a substantial reduction in the number of -positive samples that require follow-up testing. This study represents the first detailed comparison of a flow microsphere immunoassay for where the sensitivity and specificity were evaluated against established reference methods, as well as the first evaluation of performance with specimens representing both acute and nonacute infection. ACKNOWLEDGMENTS We are grateful to the Research Institute, PAMF, for providing fully characterized clinical samples and to the hospital La Timone for seroconversion panels. We also thank Craig Hixson for review and editorial corrections. REFERENCES 1. Bobic, B., D. Sibalic, and O. Djurkovic-Djakovic High levels of antibodies specific for Toxoplasma gondii in pregnancy 12 years after primary infection. Gynecol. Obstet. Investig. 31: Dannemann, B. R., W. C. Vaughan, P. Thulliez, and J. S. Remington Differential agglutination test for the diagnosis of recently acquired infection with Toxoplasma gondii. J. Clin. Microbiol. 28: Fulton, R. J., R. L. McDade, P. L. Smith, L. J. Kienker, and J. R. Kettman, Jr Advanced multiplexed analysis with the FlowMetrix system. Clin. Chem. 43: Gorgievski-Hrisoho, M., D. Germann, and L. Matter Diagnostic implications of kinetics of immunoglobulin M and A antibody responses to Toxoplasma gondii. J. Clin. Microbiol. 34: Hohlfeld, P., F. Daffos, J. M. Costa, P. Thulliez, F. Forestier, and M. Vidaud Prenatal diagnosis of congenital toxoplasmosis with a polymerase chain reaction test on amniotic fluid. N. Engl. J. Med. 331: Holland, G. N., G. R. O Connors, R. Belfort, Jr., and J. S. Remington Toxoplasmosis, p In J. S. Peprose, G. N. Holland, and K. R. Wilhelmus (ed.), Ocular infection and immunity. Mosby Yearbook, St. Louis, Mo. 7. Jani, I. V., G. Janossy, and D. W. G. Brown Multiplexed immunoassays by flow cytometry for diagnosis and surveillance of infectious diseases in resource-poor settings. Lancet 2: Jenum, P. A., B. Stray-Pedersen, and A.-G. Gundersen Improved diagnosis of primary Toxoplasma gondii infection in early pregnancy by

5 VOL. 42, 2004 BioPlex 2200 TOXOPLASMA IMMUNOASSAY 5709 determination of anti immunoglobulin G avidity. J. Clin. Microbiol. 35: Kellar, K. L., and J. P. Douglass Multiplexed microsphere-based flow cytometric immunoassays for human cytokines. J. Immunol. Methods 279: Klutts, J. S., R. S. Liao, W. M. Dunne, Jr., and A. M. Gronowski Evaluation of a multiplexed bead assay for assessment of Epstein-Barr virus immunologic status. J. Clin. Microbiol. 42: Lappalainen, M., P. Koskela, M. Koskiniemi, P. Ammala, V. Hiilesma, K. Teramo, K. O. Raivio, J. S. Remington, and K. Hedman Toxoplasmosis acquired during pregnancy: improved serodiagnosis based on avidity of IgG. J. Infect. Dis. 167: Liesenfeld, O., J. G. Montoya, S. Kinney, C. Press, and J. S. Remington Effect of testing for IgG avidity in the diagnosis of Toxoplasma gondii infection in pregnant women: experience in a US reference laboratory. J. Infect. Dis. 183: Liesenfeld, O., J. G. Montoya, N. J. Tathineni, M. Davis, B. W. Brown, Jr., K. L. Cobb, J. Parsonnet, and J. S. Remington Confirmatory serologic testing for acute toxoplasmosis and rate of induced abortions among women reported to have positive Toxoplasma immunoglobulin M antibody titers. Am. J. Obstet. Gynecol. 184: McCabe, R., and J. S. Remington Toxoplasmosis: the time has come. N. Engl. J. Med. 318: Meek, B., T. van Gool, H. Gilis, and R. Peek Dissecting the antibody response during the acute and latent phase of toxoplasmosis. Diagn. Microbiol. Infect. Dis. 41: Montoya, J. G., O. Liesenfeld, S. Kinney, C. Press, and J. S. Remington VIDAS test for avidity of Toxoplasma-specific immunoglobulin G for confirmatory testing of pregnant women. J. Clin. Microbiol. 40: Naot, Y., and J. S. Remington An enzyme-linked immunosorbent assay for detection of antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis. J. Infect. Dis. 142: Nigro, M., A. Gutierrez, A. M. Hoffer, M. Clemente, F. Kaufer, L. Carral, V. Martin, E. A. Guarnera, and S. O. Angel Evaluation of Toxoplasma gondii recombinant proteins for the diagnosis of recently acquired toxoplasmosis by an immunoglobulin G analysis. Diagn. Microbiol. Infect. Dis. 47: Pelloux, H., E. Brun, G. Vernet, S. Marcillat, M. Jolivet, D. Guergour, H. Hidalgo, A. Fleuret, and P. Ambroise-Thomas Determination of anti- Toxoplasma immunoglobulin G avidity: adaptation to the VIDAS system (biomerieux). Diagn. Microbiol. Infect. Dis. 32: Remington, J. S., R. McLeod, and G. Desmonts Toxoplasmosis, p In J. S. Remington and J. O. Klein (ed.), Infectious diseases of the fetus and newborn infant, 4th ed. The W. B. Saunders Co., Philadelphia, Pa. 21. Romand, S., M. Wallon, J. Franck, P. Thulliez, F. Peyron, and H. Dumon Prenatal diagnosis using polymerase chain reaction on amniotic fluid for congenital toxoplasmosis. Obstet. Gynecol. 97: Sabin, A. B., and H. A. Feldman Dyes as microchemical indicators of a new immunity phenomenon affecting a protozoan parasite (Toxoplasma). Science 108: Svobodova, V., and I. Literak Prevalence of and IgG antibodies to Toxoplasma gondii in blood donors in the Czech Republic. Eur. J. Epidemiol. 14: Wilson, M., J. S. Remington, C. Clavet, G. Varney, C. Press, D. Ware, and the FDA Toxoplasmosis Ad Hoc Working Group Evaluation of six commercial kits for detection of human immunoglobulin M antibodies to Toxoplasma gondii. J. Clin. Microbiol. 35: Wong, S. Y., and J. S. Remington Toxoplasmosis in pregnancy. Clin. Infect. Dis. 18: Downloaded from on January 27, 2019 by guest

VIDAS Test for Avidity of Toxoplasma-Specific Immunoglobulin G for Confirmatory Testing of Pregnant Women

VIDAS Test for Avidity of Toxoplasma-Specific Immunoglobulin G for Confirmatory Testing of Pregnant Women JOURNAL OF CLINICAL MICROBIOLOGY, July 2002, p. 2504 2508 Vol. 40, No. 7 0095-1137/02/$04.00 0 DOI: 10.1128/JCM.40.7.2504 2508.2002 Copyright 2002, American Society for Microbiology. All Rights Reserved.

More information

Effect of Testing for IgG Avidity in the Diagnosis of Toxoplasma gondii Infection in Pregnant Women: Experience in a US Reference Laboratory

Effect of Testing for IgG Avidity in the Diagnosis of Toxoplasma gondii Infection in Pregnant Women: Experience in a US Reference Laboratory 1248 Effect of Testing for IgG Avidity in the Diagnosis of Toxoplasma gondii Infection in Pregnant Women: Experience in a US Reference Laboratory Oliver Liesenfeld, 1,2,3 Jose G. Montoya, 1,2 Sandra Kinney,

More information

Evaluation of the Immunoglobulin G Avidity Test for Diagnosis of Toxoplasmic Lymphadenopathy

Evaluation of the Immunoglobulin G Avidity Test for Diagnosis of Toxoplasmic Lymphadenopathy JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 2004, p. 4627 4631 Vol. 42, No. 10 0095-1137/04/$08.00 0 DOI: 10.1128/JCM.42.10.4627 4631.2004 Copyright 2004, American Society for Microbiology. All Rights Reserved.

More information

Received 8 April 1996/Returned for modification 19 June 1996/Accepted 15 July 1996

Received 8 April 1996/Returned for modification 19 June 1996/Accepted 15 July 1996 JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 1996, p. 2526 2530 Vol. 34, No. 10 0095-1137/96/$04.00 0 Copyright 1996, American Society for Microbiology Study of Abbott Toxo IMx System for Detection of Immunoglobulin

More information

Significance of a positive Toxoplasma Immunoglobulin M test result. in the United States

Significance of a positive Toxoplasma Immunoglobulin M test result. in the United States JCM Accepted Manuscript Posted Online 9 September 2015 J. Clin. Microbiol. doi:10.1128/jcm.01663-15 Copyright 2015, American Society for Microbiology. All Rights Reserved. 1 2 Significance of a positive

More information

False-Positive Results in Immunoglobulin M (IgM) Toxoplasma Antibody Tests and Importance of Confirmatory Testing: the Platelia Toxo IgM Test

False-Positive Results in Immunoglobulin M (IgM) Toxoplasma Antibody Tests and Importance of Confirmatory Testing: the Platelia Toxo IgM Test JOURNAL OF CLINICAL MICROBIOLOGY, Jan. 1997, p. 174 178 Vol. 35, No. 1 0095-1137/97/$04.00 0 Copyright 1997, American Society for Microbiology False-Positive Results in Immunoglobulin M (IgM) Toxoplasma

More information

Immunoglobulin M Toxoplasma Antibodies

Immunoglobulin M Toxoplasma Antibodies CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, JUlY 1994, p. 401-405 Vol. 1, No. 4 1071-412X/94/$04.00+0 Copyright C) 1994, American Society for Microbiology The Vitek Immunodiagnostic Assay for Detection

More information

Reliable screening for early diagnosis

Reliable screening for early diagnosis Elecsys TORCH panel Reliable screening for early diagnosis Toxoplasmosis Rubella HSV CMV Toxoplasmosis The safe and sure approach to Toxo screening Ultrasensitive Toxo IgM optimized to detect all potential

More information

Performance of the BioPlex 2200 flow immunoassay (Bio- Rad) in critical cases of serodiagnosis of toxoplasmosis

Performance of the BioPlex 2200 flow immunoassay (Bio- Rad) in critical cases of serodiagnosis of toxoplasmosis CVI Accepts, published online ahead of print on 29 January 2014 Clin. Vaccine Immunol. doi:10.1128/cvi.00624-13 Copyright 2014, American Society for Microbiology. All Rights Reserved. 1 2 3 Performance

More information

Comparison of the efficiency of two commercial kits ELFA and Western blot in estimating the phase of Toxoplasma gondii infection in pregnant women

Comparison of the efficiency of two commercial kits ELFA and Western blot in estimating the phase of Toxoplasma gondii infection in pregnant women Annals of Agricultural and Environmental Medicine 2016, Vol 23, No 4, 570 575 www.aaem.pl ORIGINAL ARTICLE Comparison of the efficiency of two commercial kits ELFA and Western blot in estimating the phase

More information

Lecture-7- Hazem Al-Khafaji 2016

Lecture-7- Hazem Al-Khafaji 2016 TOXOPLASMOSIS Lecture-7- Hazem Al-Khafaji 2016 TOXOPLASMOSIS It is a disease caused by Toxoplasma gondii which is a protozoan parasite that is infects a variety of mammals and birds throughout the world.

More information

Simplified Assay for Measuring Toxoplasma gondii Immunoglobulin G Avidity

Simplified Assay for Measuring Toxoplasma gondii Immunoglobulin G Avidity CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, Sept. 2001, p. 904 908 Vol. 8, No. 5 1071-412X/01/$04.00 0 DOI: 10.1128/CDLI.8.5.904 908.2001 Copyright 2001, American Society for Microbiology. All Rights

More information

Non-commercial use only

Non-commercial use only Microbiologia Medica 2017; volume 32:6583 Evaluation of the TGS TA system for the detection of anti-toxoplasma antibodies Olivia Arpino, Annalisa Cianflone, Maria Teresa Manco, Alessia Paganini, Massimo

More information

Laboratory Diagnosis of Toxoplasma gondii Infection and Toxoplasmosis

Laboratory Diagnosis of Toxoplasma gondii Infection and Toxoplasmosis S73 Laboratory Diagnosis of Toxoplasma gondii Infection and Toxoplasmosis Jose G. Montoya Department of Immunology and Infectious Diseases, Research Institute, Palo Alto Medical Foundation, Palo Alto,

More information

Improved Diagnosis of Primary Toxoplasma gondii Infection in Early Pregnancy by Determination of Antitoxoplasma Immunoglobulin G Avidity

Improved Diagnosis of Primary Toxoplasma gondii Infection in Early Pregnancy by Determination of Antitoxoplasma Immunoglobulin G Avidity JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 1997, p. 1972 1977 Vol. 35, No. 8 0095-1137/97/$04.00 0 Copyright 1997, American Society for Microbiology Improved Diagnosis of Primary Toxoplasma gondii Infection

More information

Development of Specific Immunoglobulins G, M, and A Following Primary Toxoplasma gondii Infection in Pregnant Women

Development of Specific Immunoglobulins G, M, and A Following Primary Toxoplasma gondii Infection in Pregnant Women JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 1998, p. 2907 2913 Vol. 36, No. 10 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology. All Rights Reserved. Development of Specific Immunoglobulins

More information

Innovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES

Innovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES Innovation in Diagnostics ToRCH A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES EN TOXOPLASMOSIS Toxoplasmosis is a parasitic disease caused by with the obligate intracellular

More information

Utility of Immunoblotting for Early Diagnosis of Toxoplasmosis Seroconversion in Pregnant Women

Utility of Immunoblotting for Early Diagnosis of Toxoplasmosis Seroconversion in Pregnant Women CLINICAL AND VACCINE IMMUNOLOGY, Nov. 2011, p. 1908 1912 Vol. 18, No. 11 1556-6811/11/$12.00 doi:10.1128/cvi.05303-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. Utility of

More information

Modification and Evaluation of Avidity IgG Testing for Differentiating of Toxoplasma gondii Infection in Early Stage of Pregnancy

Modification and Evaluation of Avidity IgG Testing for Differentiating of Toxoplasma gondii Infection in Early Stage of Pregnancy Original Article Modification and Evaluation of Avidity IgG Testing for Differentiating of Toxoplasma gondii Infection in Early Stage of Pregnancy Mohammad Reza Bonyadi, M.D. 1 *, Parvin Bastani, M.D.

More information

Multiplex Detection of IgM and IgG Class Antibodies to Toxoplasma gondii, Rubella Virus, and Cytomegalovirus Using a Novel Multiplex Flow Immunoassay

Multiplex Detection of IgM and IgG Class Antibodies to Toxoplasma gondii, Rubella Virus, and Cytomegalovirus Using a Novel Multiplex Flow Immunoassay CLINICAL AND VACCINE IMMUNOLOGY, Nov. 2010, p. 1734 1738 Vol. 17, No. 11 1556-6811/10/$12.00 doi:10.1128/cvi.00332-10 Copyright 2010, American Society for Microbiology. All Rights Reserved. Multiplex Detection

More information

VOL 13, NO 1, JANUREY 2015 SUPPL AL-AZHAR ASSIUT MEDICAL JOURNAL

VOL 13, NO 1, JANUREY 2015 SUPPL AL-AZHAR ASSIUT MEDICAL JOURNAL AL-AZHAR ASSIUT MEDICAL JOURNAL DIAGNOSTIC TESTS TO DETECT RECENT INFECTIONS WITH TOXOPLASMA GONDII IN PREGNANT WOMEN Anwar Hosainy Abo Hashim 1 and Afaf Abdel-Ghany Attya 2 Department of Parasitology,

More information

Laboratory diagnosis of congenital infections

Laboratory diagnosis of congenital infections Laboratory diagnosis of congenital infections Laboratory diagnosis of HSV Direct staining Tzanck test Immunostaining HSV isolation Serology PCR Tzanck test Cell scrape from base of the lesion smear on

More information

TELEFAX. Toxoplasma Serology Laboratory (TSL) DATE: TO: FAX: FROM:

TELEFAX. Toxoplasma Serology Laboratory (TSL) DATE: TO: FAX: FROM: TELEFAX DATE: TO: FAX: FROM: Toxoplasma Serology Laboratory RE: SPECIMEN REQUIREMENTS AND TESTING INFORMATION (effective 1/15/16) THIS TRANSMISSION CONSISTS OF 16 PAGES INCLUDING THIS COVER PAGE. IF THERE

More information

Bio-Rad Laboratories. The Best Protection Whoever You Are. Congenital and Pediatric Disease Testing

Bio-Rad Laboratories. The Best Protection Whoever You Are. Congenital and Pediatric Disease Testing Bio-Rad Laboratories I N F E C T I O U S D I S E A S E T E S T I N G The Best Protection Whoever You Are Congenital and Pediatric Disease Testing Bio-Rad Laboratories I N F E C T I O U S D I S E A S E

More information

Serology and International units

Serology and International units Serology and International units L. Grangeot-Keros, National Reference Laboratory for Rubella, Virology Department, A. Béclère Hospital, Clamart, France Detection of rubella-specific IgG antibody Assays

More information

Toxoplasma gondii IgM (Toxo IgM)

Toxoplasma gondii IgM (Toxo IgM) DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

Rubella Latex Agglutination Test

Rubella Latex Agglutination Test Rubella Latex Agglutination Test Cat. No.:DLAT1088 Pkg.Size:30T Intended use The Rubella Latex Agglutination Test is a rapid latex particle agglutination test for the qualitative and semi-quantitative

More information

CHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) Toxoplasma IgG. Cat # (20-25 C Room temp.) Volume

CHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) Toxoplasma IgG. Cat # (20-25 C Room temp.) Volume DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

Automated microparticle enzyme immunoassays

Automated microparticle enzyme immunoassays 238 Infectious Diseases and Immunology, Diagnostic Division, Abbott Laboratories, North Chicago, Illinois 60064, USA J W Safford G G Abbott M C Craine R G MacDonald Correspondence to: J W Safford Abbott

More information

Role of Specific Immunoglobulin E in Diagnosis of Acute Toxoplasma Infection and Toxoplasmosis

Role of Specific Immunoglobulin E in Diagnosis of Acute Toxoplasma Infection and Toxoplasmosis JOURNL OF CLINICL MICROBIOLOGY, Nov. 199, p. 2952-2959 95-117/9/112952-8$2./ Copyright 199, merican Society for Microbiology Vol. 1, No. 11 Role of Specific Immunoglobulin in Diagnosis of cute Toxoplasma

More information

patient's serum is separated from other serum components by selective absorption of the IgM

patient's serum is separated from other serum components by selective absorption of the IgM JOURNAL OF CLINICAL MICROBIOLOGY, Nov. 1981, p. 486-491 0095-1137/81/1 10486-06$02.00/0 Vol. 14, No. 5 Immunoglobulin M-Immunosorbent Agglutination Assay for Diagnosis of Infectious Diseases: Diagnosis

More information

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

First Department of Microbiology, School of Medicine, Aristotle University of Thessaloniki, Greece

First Department of Microbiology, School of Medicine, Aristotle University of Thessaloniki, Greece ORIGINAL ARTICLE 10.1111/j.1469-0691.2005.01193.x Seroprevalence of Toxoplasma gondii in northern Greece during the last 20 years E. Diza, F. Frantzidou, E. Souliou, M. Arvanitidou, G. Gioula and A. Antoniadis

More information

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

SURVEILLANCE OF TOXOPLASMOSIS IN DIFFERENT GROUPS

SURVEILLANCE OF TOXOPLASMOSIS IN DIFFERENT GROUPS SURVEILLANCE OF TOXOPLASMOSIS IN DIFFERENT GROUPS Pages with reference to book, From 183 To 186 Mughisuddin Ahmed ( Department of Pathology, Dow Medical College and Basic Medical Sciences Institute, Jinnah

More information

DIAGNOSTIC AUTOMATION, INC.

DIAGNOSTIC AUTOMATION, INC. DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

Comparative evaluation of AxSYM, VIDAS and VIDIA toxoplasmosis reagent performance in a high seroprevalence Latin American country

Comparative evaluation of AxSYM, VIDAS and VIDIA toxoplasmosis reagent performance in a high seroprevalence Latin American country Artigo Original / Original Article Comparative evaluation of AxSYM, VIDAS and VIDIA toxoplasmosis reagent performance in a high seroprevalence Latin American country Avaliação comparativa entre o desempenho

More information

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing Bio-Rad Laboratories BioPlex 2200 System BioPlex 2200 MMRV IgG Kit The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing Bio-Rad

More information

Toxoplasma gondii IgM ELISA Kit

Toxoplasma gondii IgM ELISA Kit Toxoplasma gondii IgM ELISA Kit Catalog Number KA0226 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

Ocular Toxoplasmosis - A Laboratory View. Chatterton JMW* Evans R. Ho-Yen DO

Ocular Toxoplasmosis - A Laboratory View. Chatterton JMW* Evans R. Ho-Yen DO Ocular Toxoplasmosis - A Laboratory View Chatterton JMW* Evans R Ho-Yen DO Scottish Toxoplasma Reference Laboratory Microbiology Department Raigmore Hospital Inverness IV UJ * corresponding author Introduction

More information

Toxoplasmosis: Summary of evidences, a Research line

Toxoplasmosis: Summary of evidences, a Research line Toxoplasmosis: Summary of evidences, a Research line José G. Montoya, MD Associate Professor of Medicine Associate Chief for Clinical Affairs Division of Infectious Diseases Stanford University School

More information

Treponema-Specific Tests for Serodiagnosis of Syphilis: Comparative Evaluation of Seven Assays

Treponema-Specific Tests for Serodiagnosis of Syphilis: Comparative Evaluation of Seven Assays JOURNAL OF CLINICAL MICROBIOLOGY, Apr. 2011, p. 1313 1317 Vol. 49, No. 4 0095-1137/11/$12.00 doi:10.1128/jcm.02555-10 Copyright 2011, American Society for Microbiology. All Rights Reserved. Treponema-Specific

More information

Toxoplasma gondii IgM ELISA Kit

Toxoplasma gondii IgM ELISA Kit Toxoplasma gondii IgM ELISA Kit Catalog Number KA0226 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol (Cat. No.:EK-310-85) 330 Beach Road, Burlingame CA Tel: 650-558-8898 Fax: 650-558-1686 E-Mail: info@phoenixpeptide.com www.phoenixpeptide.com INTENDED

More information

Method for Avoiding False-Positive Results Occurring in Immunoglobulin M Enzyme-Linked Immunosorbent Assays

Method for Avoiding False-Positive Results Occurring in Immunoglobulin M Enzyme-Linked Immunosorbent Assays JOURNAL OF CLINICAL MICROBIOLOGY, July 1981, p. 73-78 0095-1 137/81/070073-06$02.00/0 Vol. 14, No. 1 Method for Avoiding False-Positive Results Occurring in Immunoglobulin M Enzyme-Linked Immunosorbent

More information

Enzyme Immunoassay (EIA) for the Detection of Toxoplasma IgG Antibodies in Human Serum. For In Vitro Diagnostic Use Only

Enzyme Immunoassay (EIA) for the Detection of Toxoplasma IgG Antibodies in Human Serum. For In Vitro Diagnostic Use Only TOXOPLASMA IgG EIA ID: Blue Enzyme Immunoassay (EIA) for the Detection of Toxoplasma IgG Antibodies in Human Serum. For In Vitro Diagnostic Use Only 25175 96 Tests CONTENTS 1 - INTENDED USE 2 - SUMMARY

More information

Cytomegalovirus IgG, IgM, IgG Avidity II Total automation for accurate staging of infection during pregnancy

Cytomegalovirus IgG, IgM, IgG Avidity II Total automation for accurate staging of infection during pregnancy Infectious Disease Cytomegalovirus IgG, IgM, IgG Avidity II Total automation for accurate staging of infection during pregnancy FOR OUTSIDE THE US AND CANADA ONLY Confidence in Your Results LIAISON Cytomegalovirus

More information

Molecular Markers in Acute and Chronic Phases of Human Toxoplasmosis: Determination of Immunoglobulin G Avidity by Western Blotting

Molecular Markers in Acute and Chronic Phases of Human Toxoplasmosis: Determination of Immunoglobulin G Avidity by Western Blotting CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, May 2000, p. 384 389 Vol. 7, No. 3 1071-412X/00/$04.00 0 Copyright 2000, American Society for Microbiology. All Rights Reserved. Molecular Markers in Acute

More information

Toxoplasmosis Objective :

Toxoplasmosis Objective : Toxoplasmosis Objective : Describe the Life cycle Mention the Infective stages Define Congenital Toxoplasmosis List the Lab.Diagnosis Illustrate the Immunity to Toxoplasmosis Show the relationship between

More information

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit Human Cytomegalovirus Virus Catalog No: IRAPKT1410 (CMV) IgG ELISA Kit Lot No: SAMPLE INTENDED USE The CMV IgG ELISA is intended for use in evaluating a patient s serologic status to cytomegalovirus (CMV)

More information

See external label 96 tests HSV 2 IgA. Cat #

See external label 96 tests HSV 2 IgA. Cat # DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

Susanne Norris Zanto, MPH, MLS (ASCP) CM, SM Montana Public Health Laboratory

Susanne Norris Zanto, MPH, MLS (ASCP) CM, SM Montana Public Health Laboratory Susanne Norris Zanto, MPH, MLS (ASCP) CM, SM Montana Public Health Laboratory Describe the challenges in syphilis diagnostics Present two testing algorithms Non-treponemal test as initial screen Treponemal

More information

Contribution of IgG avidity and PCR for the early diagnosis of toxoplasmosis in pregnant women from the North-Eastern region of Algeria.

Contribution of IgG avidity and PCR for the early diagnosis of toxoplasmosis in pregnant women from the North-Eastern region of Algeria. Contribution of IgG avidity and PCR for the early diagnosis of toxoplasmosis in pregnant women from the North-Eastern region of Algeria. Hajira Berredjem 1,2, Hayette Aouras 3, Meriem Benlaifa 2, Imène

More information

Evidence-based diagnosis of toxoplasma infection Evans R, Ho-Yen D O

Evidence-based diagnosis of toxoplasma infection Evans R, Ho-Yen D O Evidence-based diagnosis of toxoplasma infection Evans R, Ho-Yen D O Record Status This is a critical abstract of an economic evaluation that meets the criteria for inclusion on NHS EED. Each abstract

More information

agglutination assay (ISAGA) for detecting toxoplasma specific IgM

agglutination assay (ISAGA) for detecting toxoplasma specific IgM J Clin Pathol 1989;42:1291-1295 Assessment of immunoglobulin-m immunosorbent agglutination assay (ISAGA) for detecting toxoplasma specific IgM KIM T DUFFY, P J WHARTON, JULIE D JOHNSON, LINDA NEW, R E

More information

Rubella virus IgG ELISA Kit

Rubella virus IgG ELISA Kit Rubella virus IgG ELISA Kit Catalog Number KA0223 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of

More information

Evaluation of IgG Avidity for Diagnosis of Acute Toxoplasma gondii Compared to Nested PCR in Pregnant Women in First Trimester

Evaluation of IgG Avidity for Diagnosis of Acute Toxoplasma gondii Compared to Nested PCR in Pregnant Women in First Trimester Journal of Advances in Medicine 3(1), 31-41, June 2014 3 DOI No. 10.5958/2319-4324.2014.01121.3 Evaluation of IgG Avidity for Diagnosis of Acute Toxoplasma gondii Compared to Nested PCR in Pregnant Women

More information

PREDICTIVE VALUE OF LATEX AGGLUTINATION TEST IN SEROLOGICAL SCREENING FOR TOXOPLASMA GONDII

PREDICTIVE VALUE OF LATEX AGGLUTINATION TEST IN SEROLOGICAL SCREENING FOR TOXOPLASMA GONDII PREDICTIVE VALUE OF LATEX AGGLUTINATION TEST IN SEROLOGICAL SCREENING FOR TOXOPLASMA GONDII Yaowalark Sukthana, Thaiyooth Chintana, Waraporn Supatanapong, Chutatip Siripan, Amorn Lekkla and Rachatawan

More information

Treponemal-Specific Tests for the Serodiagnosis of Syphilis: A Comparative Evaluation of Seven Assays

Treponemal-Specific Tests for the Serodiagnosis of Syphilis: A Comparative Evaluation of Seven Assays JCM Accepts, published online ahead of print on 23 February 2011 J. Clin. Microbiol. doi:10.1128/jcm.02555-10 Copyright 2011, American Society for Microbiology and/or the Listed Authors/Institutions. All

More information

Int.J.Curr.Microbiol.App.Sci (2018) 7(1):

Int.J.Curr.Microbiol.App.Sci (2018) 7(1): International Journal of Current Microbiology and Applied Sciences ISSN: 2319-7706 Volume 7 Number 01 (2018) Journal homepage: http://www.ijcmas.com Original Research Article https://doi.org/10.20546/ijcmas.2018.701.373

More information

Herpes Simplex Virus 2 IgM HSV 2 IgM

Herpes Simplex Virus 2 IgM HSV 2 IgM DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

Evidence-Based Approach for Interpretation of Epstein-Barr Virus Serological Patterns

Evidence-Based Approach for Interpretation of Epstein-Barr Virus Serological Patterns JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 2009, p. 3204 3210 Vol. 47, No. 10 0095-1137/09/$08.00 0 doi:10.1128/jcm.00164-09 Copyright 2009, American Society for Microbiology. All Rights Reserved. Evidence-Based

More information

READ HIGHLIGHTED CHANGES

READ HIGHLIGHTED CHANGES BIO-FLASH Toxo IgM 3000-8554 50 tests The BIO-FLASH Toxo IgM is a fully automated chemiluminescent two-step immunoassay for qualitative measurement of IgM antibodies to Toxoplasma gondii in human serum

More information

Identification of Microbes Lecture: 12

Identification of Microbes Lecture: 12 Diagnostic Microbiology Identification of Microbes Lecture: 12 Electron Microscopy 106 virus particles per ml required for visualization, 50,000-60,000 magnification normally used. Viruses may be detected

More information

National Prevalence Estimates for Cytomegalovirus IgM and IgG Avidity and Association between High IgM Antibody Titer and Low IgG Avidity

National Prevalence Estimates for Cytomegalovirus IgM and IgG Avidity and Association between High IgM Antibody Titer and Low IgG Avidity CLINICAL AND VACCINE IMMUNOLOGY, Nov. 2011, p. 1895 1899 Vol. 18, No. 11 1556-6811/11/$12.00 doi:10.1128/cvi.05228-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. National Prevalence

More information

See external label 2 C-8 C Σ=96 tests Cat # 3171Z. Free Estriol. Cat # 3171Z. Enzyme Linked Immunosorbent Assay

See external label 2 C-8 C Σ=96 tests Cat # 3171Z. Free Estriol. Cat # 3171Z. Enzyme Linked Immunosorbent Assay DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

A 39 years old HIV-positive black African woman with previously treated cerebral

A 39 years old HIV-positive black African woman with previously treated cerebral 1 Abstract A 39 years old HIV-positive black African woman with previously treated cerebral toxoplasmosis experienced a foetal intra-uterine death due to congenital toxoplasmosis. This case demonstrates

More information

Evaluation of the New Architect Cytomegalovirus Immunoglobulin M (IgM), IgG, and IgG Avidity Assays

Evaluation of the New Architect Cytomegalovirus Immunoglobulin M (IgM), IgG, and IgG Avidity Assays JOURNAL OF CLINICAL MICROBIOLOGY, June 2009, p. 1695 1699 Vol. 47, No. 6 0095-1137/09/$08.00 0 doi:10.1128/jcm.02172-08 Copyright 2009, American Society for Microbiology. All Rights Reserved. Evaluation

More information

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

H.Pylori IgG Cat # 1503Z

H.Pylori IgG Cat # 1503Z DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

INTERNATIONAL JOURNAL CEUTICAL RESEARCH AND

INTERNATIONAL JOURNAL CEUTICAL RESEARCH AND Research Article CODEN: IJPRNK B. V. Ramana, IJPRBS, 2013; Volume 2(4): 253-258 ISSN: 2277-8713 IJPRBS INTERNATIONAL JOURNAL OF PHARMAC CEUTICAL RESEARCH AND BIO-SCIENCE SEROPREVALENCE OF ACUTE TOXOPLASMOSIS

More information

HYPERIMMUNOGLOBULIN and CMV- DNAemia IN PREGNANT WOMEN WITH PRIMARY CYTOMEGALOVIRUS INFECTION

HYPERIMMUNOGLOBULIN and CMV- DNAemia IN PREGNANT WOMEN WITH PRIMARY CYTOMEGALOVIRUS INFECTION HYPERIMMUNOGLOBULIN and CMV- DNAemia IN PREGNANT WOMEN WITH PRIMARY CYTOMEGALOVIRUS INFECTION Giovanni Nigro, Rome, Italy Stuart P Adler, Richmond, VA, USA To avoid fetal rejection (50% allograft) an estrogeninduced

More information

Short Video. shows/monsters-inside- me/videos/toxoplasma-parasite/

Short Video.  shows/monsters-inside- me/videos/toxoplasma-parasite/ The word Toxoplasma Originated from the Greek word toxon, which meant "bow." The Latin word toxicum, which meant "poison." The original Greek meaning is the one used for the word Toxoplasma, meaning "bow

More information

Immunoglobulin-A detection and the investigation of clinical toxoplasmosis

Immunoglobulin-A detection and the investigation of clinical toxoplasmosis J. Med. Microbiol. - Vol. 38 (1993), 286-292 1993 The Pathological Society of Great Britain and Ireland Immunoglobulin-A detection and the investigation of clinical toxoplasmosis BINDYA PATEL, YVONNE YOUNG,

More information

Herpes Simplex Virus 2 IgG HSV 2 IgG

Herpes Simplex Virus 2 IgG HSV 2 IgG DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

H.pylori IgA Cat #

H.pylori IgA Cat # DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

ToRCH IgG Plus Test System

ToRCH IgG Plus Test System ToRCH IgG Plus Test System A81101G INTENDED USE The ZEUS AtheNA Multi-Lyte ToRCH IgG Plus Test System is intended intended for the qualitative detection of specific human IgG class antibodies to Toxoplasma

More information

Comparison of three automated immunoassay methods for the determination of

Comparison of three automated immunoassay methods for the determination of CVI Accepts, published online ahead of print on 0 February 00 Clin. Vaccine Immunol. doi:0./cvi.00-0 Copyright 00, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved.

More information

Toxo IgG. Principle of the Test. Introduction

Toxo IgG. Principle of the Test. Introduction Toxo IgG E Principle of the Test The ImmunoComb Toxo IgG test is an indirect solid-phase enzyme immunoassay (EIA). The solid phase is a card with 12 projections ("teeth"). Each tooth is sensitized at two

More information

Answering your daily challenges. in the ELISA technology I N FECTI OUS DISEASES. bioelisa

Answering your daily challenges. in the ELISA technology I N FECTI OUS DISEASES. bioelisa Answering your daily challenges in the ELISA technology I N FECTI OUS DISEASES bioelisa RETROVIRUS HIV is the cause of the most important global pandemic. Due to the lack of vaccination, early diagnosis

More information

Comparison of Three Automated Immunoassay Methods for the Determination of Epstein-Barr Virus-Specific Immunoglobulin M

Comparison of Three Automated Immunoassay Methods for the Determination of Epstein-Barr Virus-Specific Immunoglobulin M CLINICAL AND VACCINE IMMUNOLOGY, Apr. 2010, p. 559 563 Vol. 17, No. 4 1556-6811/10/$12.00 doi:10.1128/cvi.00372-09 Copyright 2010, American Society for Microbiology. All Rights Reserved. Comparison of

More information

Centers for Disease Control and Prevention Zika Diagnosis: Challenges and Opportunities

Centers for Disease Control and Prevention Zika Diagnosis: Challenges and Opportunities Centers for Disease Control and Prevention Zika Diagnosis: Challenges and Opportunities Jorge L. Muñoz-Jordán, Ph.D. Chief, Surveillance and Research Laboratory Centers for Disease Control and Prevention

More information

JOURNAL OF INTERNATIONAL ACADEMIC RESEARCH FOR MULTIDISCIPLINARY Impact Factor 1.393, ISSN: , Volume 2, Issue 2, March 2014

JOURNAL OF INTERNATIONAL ACADEMIC RESEARCH FOR MULTIDISCIPLINARY Impact Factor 1.393, ISSN: , Volume 2, Issue 2, March 2014 PRELIMINARY EVALUATION OF CHORUS SYSTEM IN COMPARISON WITH COBAS 6000 SYSTEM FOR DETECTION OF ANTI-TOXOPLASMA-IGM ANTIBODIES BLERTA LAZE* ANILA MITRE** *Dept. of Biology, University Ismail Qemali, Vlora,

More information

H.Pylori IgG

H.Pylori IgG DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

Toxoplasmosis. Life cycle Infective stages Congenital Toxoplasmosis Lab.Diagnosis Immunity to Toxoplasmosis Toxoplasmosis & Pregnancy

Toxoplasmosis. Life cycle Infective stages Congenital Toxoplasmosis Lab.Diagnosis Immunity to Toxoplasmosis Toxoplasmosis & Pregnancy Toxoplasmosis Life cycle Infective stages Congenital Toxoplasmosis Lab.Diagnosis Immunity to Toxoplasmosis Toxoplasmosis & Pregnancy Human Toxoplasmosis Toxoplasmosis is a zoonotic disease Caused by Coccidian

More information

Identifying false-positive syphilis antibody results using a semi-quantitative

Identifying false-positive syphilis antibody results using a semi-quantitative CVI Accepts, published online ahead of print on 20 April 2011 Clin. Vaccine Immunol. doi:10.1128/cvi.05066-11 Copyright 2011, American Society for Microbiology and/or the Listed Authors/Institutions. All

More information

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol (Cat. No.:EK-310-91) 330 Beach Road, Burlingame CA Tel: 650-558-8898 Fax: 650-558-1686 E-Mail: info@phoenixpeptide.com www.phoenixpeptide.com INTENDED USE The

More information

4/18/2018. Syphilis Testing. Disclosure. Learner Objectives. Outline. Employee and stockholder of Bio-Rad Laboratories, Inc.

4/18/2018. Syphilis Testing. Disclosure. Learner Objectives. Outline. Employee and stockholder of Bio-Rad Laboratories, Inc. Disclosure Employee and stockholder of Bio-Rad Laboratories, Inc. Unraveling the Complexities of Syphilis Testing Maria Crisostomo, April 30 & May 1, 2018 2 Learner Objectives Syphilis Testing Upon completion

More information

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

Human Cytomegalovirus IgM ELISA Kit

Human Cytomegalovirus IgM ELISA Kit Human Cytomegalovirus IgM Catalog No: IRAPKT2012 ELISA Kit Lot No: SAMPLE INTENDED USE The CMV IgM ELISA is intended for use in the detection of IgM antibodies to Cytomegalovirus (CMV) infection in human

More information

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com H. pylori

More information

FOR IN VITRO DIAGNOSTIC USE

FOR IN VITRO DIAGNOSTIC USE Arlington Scientific, Inc. Page 1 of 10 Created by: Approved By: Date: FOR IN VITRO DIAGNOSTIC USE 1.0 INTENDED USE: For the qualitative and quantitative detection of human IgM antibodies to Toxoplasma

More information

VZV IgG ELISA Catalog No (96 Tests)

VZV IgG ELISA Catalog No (96 Tests) INTENDED USE For Research Use Only. Not for use in Diagnostic Procedures. The GenWay, Inc. Kit is intended for the detection of IgG antibody to VZV in human serum or plasma. SUMMARY AND EXPLANATION Varicella

More information

Clinical Evaluation of a Chemiluminescence Immunoassay for Determination of Immunoglobulin G Avidity to Human Cytomegalovirus

Clinical Evaluation of a Chemiluminescence Immunoassay for Determination of Immunoglobulin G Avidity to Human Cytomegalovirus CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, July 2004, p. 801 805 Vol. 11, No. 4 1071-412X/04/$08.00 0 DOI: 10.1128/CDLI.11.4.801 805.2004 Copyright 2004, American Society for Microbiology. All Rights

More information

Micropathology Ltd. University of Warwick Science Park, Venture Centre, Sir William Lyons Road, Coventry CV4 7EZ

Micropathology Ltd. University of Warwick Science Park, Venture Centre, Sir William Lyons Road, Coventry CV4 7EZ www.micropathology.com info@micropathology.com Micropathology Ltd Tel 24hrs: +44 (0) 24-76 323222 Fax / Ans: +44 (0) 24-76 - 323333 University of Warwick Science Park, Venture Centre, Sir William Lyons

More information

Detection of acute Toxoplasma gondii infection in pregnant women by IgG avidity and PCR analysis

Detection of acute Toxoplasma gondii infection in pregnant women by IgG avidity and PCR analysis Tropical Biomedicine 35(4): 908 914 (2018) Detection of acute Toxoplasma gondii infection in pregnant women by IgG avidity and PCR analysis Roozbehani, M. 1, Gharavi, M.J. 2*, Moradi, M. 3 and Razmjou,

More information

UKNEQAS Toxoplasma Serology. It is the fault of the kits or is it?

UKNEQAS Toxoplasma Serology. It is the fault of the kits or is it? UKNEQAS Toxoplasma Serology It is the fault of the kits or is it? Purpose of the Schemes The Toxoplasma subschemes consist of IgG and IgM and are designed to: Provide information allowing participants

More information

MKT/BF/328

MKT/BF/328 19.06.2013 MKT/BF/328 BIO-FLASH posters presented at ECCMID, 23rd Congress of Clinical Microbiology and Infectious Diseases Evaluation of HBV/HCV/HIV 1+2 Evaluation of TORC panel As you know this year

More information

an antirubella antibody labelled with iodine-125 not require purified rubella antigen and, in general, are resistant to false positive results due to

an antirubella antibody labelled with iodine-125 not require purified rubella antigen and, in general, are resistant to false positive results due to J Clin Pathol 1985;38:1150-1154 Public Health Laboratory Service IgM antibody capture enzyme linked immunosorbent assay for detecting rubella specific IgM KATHRYN BELLAMY,* J HODGSON,t PS GARDNER,* P MORGAN-CAPNERt

More information