VITROS MicroTip Assay Summary

Size: px
Start display at page:

Download "VITROS MicroTip Assay Summary"

Transcription

1 AAT α-antitrypsin AMPH Amphetamine ApoA1 Apolipoprotein A1 ApoB Apolipoprotein B1 ASO Antistreptolysin O BARB Barbiturates BENZ Benzodiazapines C3 Complement C AAT/HPT PV FS Pack 2 (Saline dilution) 1 Urine EDTA mg/dl g/l DAT PV FS Pack ng/ml μg/l ApoA1 PV FS Pack mg/dl g/l ApoB PV FS Pack mg/dl g/l FS1 Urine Urine ASO/RF PV Isotonic saline IU/mL kiu/l (kiu/l = IU/mL x 1) DAT PV FS Pack ng/ml μg/l DAT PV FS Pack ng/ml μg/l Protein PV FS Pack mg/dl mg/l mg/dl g/l days Cutoff 500 ng/ml Negative: <500 ng/ml Positive: 500 ng/ml Cutoff 1000 ng/ml Negative: <1000 ng/ml Positive: 1000 ng/ml mg/dl g/l mg/dl g/l Adult: Children: Cutoff 200 ng/ml Negative: <200 ng/ml Positive: 200 ng/ml Cutoff 200 ng/ml Negative: <200 ng/ml Positive: 200 ng/ml 200 IU/mL 240 IU/mL Positive: 300 ng/ml Positive: 300 ng/ml days mg/dl mg/l Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

2 C4 Complement C4 CAFFN Caffeine (includes calibrators) COCM Cocaine Metabolites dldl Direct LDLC dtibc Direct Total Iron- Binding Capacity EDTA Urine Protein PV FS Pack mg/dl mg/l 2 15 TDM PV FS Pack μg/ml μmol/l μmol/l = μg/ml x 5.15) , FS1 DAT PV FS Pack ng/ml μg/l PV FS Pack mg/dl mmol/l (mmol/l = mg/dl x ) dtibc PV FS Pack μg/dl μmol/l (μmol/l = μg/dl x 0.179) mg/dl mg/l Therapeutic: 8 20 μg/ml Toxic: >50 μg/ml Cutoff 150 ng/ml Negative: <150 ng/ml Positive: 150 ng/ml Optimal: <100 mg/dl Near to above Optimal: mg/dl Borderline High: mg/dl High: mg/dl Very High: 190mg/dL Male: μg/dl Female: μg/dl μmol/l >258 μmol/l Positive: 300 ng/ml <2.59 mmol/l mmol/l mmol/l mmol/l 4.91 mmol/l μmol/l μmol/l days days Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

3 GENT Gentamicin HbA1c Direct % Glycated Hemoglobin HCY 2 Homocysteine HPT Haptoglobin hscrp High-Sensitivity C-Reactive Protein IgA Immunoglobulin A IgG Immunoglobulin G EDTA EDTA Whole blood EDTA EDTA EDTA 3 13 TDM PV FS Pack μg/ml μmol/l 2.16) HbA1c: 5 Hb: 5 31 %A1c PV Isotonic saline 4 14 %A1c NGSP HbA1c (mmol/mol) Therapeutic Trough: <1.00 μg/ml <2.00 μg/ml Toxic Trough: 2.00 μg/ml Therapeutic Peak: μg/ml μg/ml Toxic Peak: >12.00 μg/ml 6.5 %A1c NGSP 48 Calculated HbA1c (mmol/mol) SI Units HCY 2 PV FS Pack μmol/l Male: Female: AAT/HPT PV FS1 FS Pack mg/dl g/l hscrp PV Do not dilute mg/l Low: Average: High: Indeterminant: Protein PV FS Pack mg/dl g/l Protein PV FS Pack mg/dl g/l <2.16 μmol/l <4.32 μmol/l 4.32 μmol/l μmol/l μmol/l >25.92 μmol/l Action Suggested Action Suggested μmol/l μmol/l 1 week Hb- A1c: days Hb: 340/ days mg/dl g/l days <1.0 mg/l 1.0 to 3.0 mg/l > mg/l >10.0 mg/l mg/dl g/l mg/dl g/l Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

4 IgM Immunoglobulin M malb Micro Albumin METD Methadone OP Opiates PALB Prealbumin PCP Phencyclidine EDTA Protein PV FS Pack mg/dl g/l Urine malb PV FS Pack mg/dl mg/l Urine 4 26 DAT PV FS Pack ng/ml μg/l Urine OP-LO 8 OP-HI 2 Urine DAT PV FS Pack 4 OP-LO: ng/ml (μg/l) OP-HI: ng/ml (μg/l) PALB PV FS Pack mg/dl mg/l DAT PV FS Pack ng/ml μg/l mg/dl g/l Cutoff 150 ng/ml Negative: <150 ng/ml Positive: 150 ng/ml (OP-LO) Positive: 300 ng/ml <1.7 mg/dl <16.7 mg/l Positive: 300 ng/ml Cutoff 2000 ng/ml (OP-HI) Negative: <2000 ng/ml Positive: 2000 ng/ml 1 week days mg/dl mg/l Cutoff 25 ng/ml Negative: <25 ng/ml Positive: 25 ng/ml RF Rheumatoid Factor THC Cannabinoids EDTA 5 16 Urine 6 30 ASO/RF PV FS Pack IU/mL klu/l (klu/l = IU/mL x 1) DAT PV FS Pack ng/ml μg/l Cutoff 20 ng/ml Negative: <20 ng/ml Positive: 20 ng/ml <12 IU/mL <12 klu/l Cutoff 50 ng/ml Negative: <50 ng/ml Positive: 50 ng/ml days Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

5 Reaction Sample TOBRA Tobramycin EDTA 3 14 TDM PV FS Pack μg/ml μmol/l 2.14) Therapeutic Trough: <1.00 μg/ml <2.00 μg/ml Toxic Trough: 2.00 μg/ml Therapeutic Peak: μg/ml μg/ml Toxic Peak: >12.00 μg/ml <2.14 μmol/l <4.28 μmol/l 4.28 μmol/l μmol/l μmol/l >25.68 μmol/l 3 weeks TRFRN Transferrin VALP Valproic acid VANC Vancomycin EDTA EDTA EDTA Protein PV FS Pack mg/dl g/l 3 12 TDM PV FS Pack μg/ml μmol/l 6.93) 3 11 TDM PV FS Pack μg/ml μmol/l 0.67) mg/dl g/l Minimal: 50.0 μg/ml Therapeutic: μg/ml Possible Toxic: >100.0 μg/ml Serious Toxic: >200.0 μg/ml Therapeutic Trough: μg/ml Toxic Peak: μg/ml μmol/l μmol/l >693.0 μmol/l > μmol/l μmol/l μmol/l 1 week days Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

6 Ortho-Clinical Diagnostics, Inc., 2017 VITROS is a registered trademark of Ortho-Clinical Diagnostics, Inc. 100 Indigo Creek Drive Rochester, NY

Part No. J04498 Cat No Performance Verifiers: Training Module

Part No. J04498 Cat No Performance Verifiers: Training Module Cat No. 680 0325 : Training Module Export authorized under general license GTDA (General Technical Data Available) IMPORTANT The information contained herein is based on the experience and knowledge relating

More information

cobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines

cobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines cobas c 501 analyzer and cobas c 311 analyzer General Information How to use these guidelines Unless otherwise indicated, the data presented is the same for both the cobas c 501 analyzer and the cobas

More information

URGENT FIELD SAFEY NOTICE

URGENT FIELD SAFEY NOTICE April x, 2015 URGENT FIELD SAFETY NOTICE Software Anomaly using VITROS 5,1 FS Chemistry Systems Dear Customer, As part of a Field Safety Corrective Action, the purpose of this notification is to inform

More information

Turbidos. Design Verification. Contents

Turbidos. Design Verification. Contents Design Verification Turbidos Contents 1 adjustment... 2 2 Target value determination... 2 3 Stability... 2 3.1 Accelerated stress data... 2 3.2 Open vial stability... 3 3.3 Real Time Stability... 4 4 Result

More information

VITROS MicroSlide Assay Summary

VITROS MicroSlide Assay Summary ACET Acetaminophen ALB Albumin EDTA 10 9 TDM PV Specialty 5.5 4 PV Isotonic saline or 10 200 μg/ml 66 1323 μmol/l (μmol/l = μg/ml x 6.616) 1.00 6.00 g/dl 10.0-60.0 g/l (g/l = g/dl x 10) Therapeutic: 670

More information

Reagents on COBAS INTEGRA Systems

Reagents on COBAS INTEGRA Systems within specification within specification Lipemia AAGP α1-acid Glycoprotein X X no no no no no no no AAGP2 α1-acid Glycoprotein Gen.2 X X X 60 60 1000 1026 1026 621 700 AAT2 α1-antitrypsin ver.2 X X X

More information

QUALITY CONTROL. Linearity Sets

QUALITY CONTROL. Linearity Sets QUALITY CONTROL Linearity Sets The new Acusera Linearity Sets have been designed with convenience in mind, helping you to easily meet CLIA requirements for calibration verification and assessment of linearity.

More information

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS Advancing Biochemistry Testing for Laboratories CONTENTS 01 06 43 46 53 55 60 BENEFITS OF RANDOX REAGENTS REAGENTS - RANDOX THIRD PARTY REAGENTS

More information

Excellence and confidence

Excellence and confidence Thermo Scientific System Reagents Fully supported and guaranteed, CE marked system solutions Streamlined supply and support Maximum stability and reduced waste Standardised performance in External Quality

More information

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Thermo Scientific Konelab System Reagents For convenient and reliable analysis Thermo Scientific Konelab System Reagents For convenient and reliable analysis Part of Thermo Fisher Scientific Thermo Scientific Konelab system reagents ensure the high quality analysis results Easy-to-use

More information

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-EP-19851-01-00 according to DIN EN ISO/IEC 17043:2010 Period of validity: 10.04.2017 to 21.01.2021 Holder of certificate: ESfEQA

More information

Thermo Scientific System Reagents Excellence in Clinical Chemistry

Thermo Scientific System Reagents Excellence in Clinical Chemistry Thermo Scientific System Reagents Excellence in Clinical Chemistry Part of Thermo Fisher Scientific Covering over 150 CE marked products, Thermo Scientific system reagents are specifically developed and

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

DEDICATED LINES LÍNEAS DEDICADAS

DEDICATED LINES LÍNEAS DEDICADAS DEDICATED LINES LÍNEAS DEDICADAS DEDICATED LINES LÍNEAS DEDICADAS SPINLAB / SELECTRA - FLEXOR SYSTEM PRODUCT PRODUCTO METHOD MÉTODO SIZE PRESENTACIÓN REF. CÓDIGO BIOCHEMISTRY BIOQUÍMICA ALBUMIN ALBÚMINA

More information

Quick Reference Guide. on Turbodyne SC

Quick Reference Guide. on Turbodyne SC RF Turbodyne RF Quantitative turbidimetric immunoassay for determination of Rheumatoid Factors Turbodyne RF is used for the detection of Rheumatoid Arthritis (RA), Differential diagnosis of RA from Rheumatic

More information

Optimized for best performance in clinical chemistry testing

Optimized for best performance in clinical chemistry testing Optimized for best performance in clinical chemistry testing System Reagents for Indiko and Konelab clinical and specialty chemistry analyzers Complete system solutions Thermo Scientific system reagents

More information

NORTH SHORE - LONG ISLAND JEWISH HEALTH SYSTEM LONG ISLAND JEWISH MEDICAL CENTER DEPARTMENT OF LABORATORY MEDICINE REFERENCE RANGES

NORTH SHORE - LONG ISLAND JEWISH HEALTH SYSTEM LONG ISLAND JEWISH MEDICAL CENTER DEPARTMENT OF LABORATORY MEDICINE REFERENCE RANGES S A2 COLUMN 0D 2.0-3.5 2.0-3.5 % ACETAMINOPHEN 0D 5-25 5-25 > 150 ug/ml > 50 ug/ml 12 hour post ingestion > 100 ug/ml 8 hour post ingestion > 200 ug/ml 4 hour post ingestion ACTIVATED PROTEIN C RESIS 0D

More information

Traceability in External Quality Assessment: How Weqas ensures traceability in EQA and stresses its importance to users. David Ducroq.

Traceability in External Quality Assessment: How Weqas ensures traceability in EQA and stresses its importance to users. David Ducroq. Traceability in External Quality Assessment: How Weqas ensures traceability in EQA and stresses its importance to users David Ducroq Weqas Unit 6, Parc Tŷ Glas Llanishen Cardiff UK www.weqas.com Programme

More information

Technical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP)

Technical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP) Technical Bulletin Performance Characteristics of the BN ProSpecä System By Liana Frances Romero, BS, MT(ASCP) Introduction The BN ProSpecä System is an automated nephelometry analyzer for in vitro diagnostic

More information

Carry-over Evasion List

Carry-over Evasion List Version 22 Note: It is possible that non-roche reagents may cause carry-over interference. Roche is not responsible for any carry-over interference caused by non-roche reagents. Urea and Ammonia should

More information

Assay Information For COBAS INTEGRA Systems

Assay Information For COBAS INTEGRA Systems Information For COBAS INTEGRA Systems General Information e contents of this document, including all graphics and photographs, are the property of Roche Diagnostics. No part of this document may be reproduced

More information

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently.

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently. MEMORANDUM Originating Department Chemical Pathology Issued By: Issued To: Subject: Details: Dr. Shari Srinivasan All Laboratory Service Users Change in Chemical Pathology Analysers Dear Colleague, As

More information

SydPath Reference Intervals for Clinical Trials (Contract Pathology Unit) Unauthorised Copy

SydPath Reference Intervals for Clinical Trials (Contract Pathology Unit) Unauthorised Copy HAEMATOLOGY APTT 1 150 M 25 35 sec APTT 1 150 F 25 35 sec Basophils Cord 2 weeks M 0.0 0.4 10^9/L Basophils Cord 2 weeks F 0.0 0.4 10^9/L Basophils 2 wks 3 mths M 0.0 0.2 10^9/L Basophils 2 wks 3 mths

More information

6/6/2016 pg. 1 of 24

6/6/2016 pg. 1 of 24 Last Reviewed: (Updated 06.06.16) By: Dr. Heidi Budke LTR29828 (BVH and ACC shared reference ranges) Hematology Reference Ranges: WBC LH750 AND 0-1 Day 9.0-30.0 DXH800 1-3 Days 9.4-34.0 4 Days - 1 Month

More information

Types of target values, acceptable ranges

Types of target values, acceptable ranges Types of target values, acceptable ranges As the differential of rounding, maximum 1 percent point deviation is allowed from the maximum acceptable range. 100. Clinical chemistry (wet) 1. Calcium RMV 10

More information

Please contact the Client Services Team if you require further information.

Please contact the Client Services Team if you require further information. Reference ranges are quoted on all reports where appropriate for the test carried out. The reference range and reporting units, including any interpretive information, is specific to the methodology used

More information

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-EP-19851-01-00 according to DIN EN ISO/IEC 17043:2010 Period of validity: 24.08.2018 to 21.01.2021 Holder of certificate: ESfEQA

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Program Analyte Unit Target Limit Absolute SD %

Program Analyte Unit Target Limit Absolute SD % Andrology Sperm Count 1.0E06/mL Peer Group Mean SD 2 Sperm Morphology % normal Peer Group Mean SD 2 Sperm Viability % viable Peer Group Mean SD 2 Endocrinology Cortisol µg/dl Peer Group Mean % of Target

More information

Alaska Native Medical Center Anchorage, AK

Alaska Native Medical Center Anchorage, AK ANMC Lab Test Requirements Key: Room Temp (20-25C), Refrigerated (2-8C), (-15 to -25C), Hr (Hours), D (Days), W (Weeks), Mo (Months), Yr (Years). Basic Processing Instructions: Centrifuge all blood specimens

More information

Your Results are Our Priority.

Your Results are Our Priority. Your Results are Our Priority. Enzyme Linked Immunosorbent Assay (ELISA) One year shelf life Ready to use, color coded reagents and bottles Single dilution factor Adaptable for all forensic matrices Forensic

More information

GRADING CRITERIA for CMS Regulated Analytes

GRADING CRITERIA for CMS Regulated Analytes CLIA '88 AND GRADING The Clinical Laboratory Improvement Amendments of 1988 (CLIA '88) were established by the federal government (CMS) to regulate clinical laboratories and proficiency test providers

More information

VITROS MicroWell Assay Summary

VITROS MicroWell Assay Summary 3,63,6 VITROS MicroWell Assay Summary s / Reagents AFP AFP Anti-HAV IgM 2 HAV M Anti-HAV Total 2 HAV T Anti- Hc 2 ahc Amniotic Fluid 25 43 AFP 10 43 Anti-HAV IgM 10 53 Anti-HAV Total 50 55 Anti-Hc RE A

More information

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with: WSLH PT roficiency esting Calibration Verification/ Linearity Products Products provided in partnership with: www.wslhpt.org 800-462-5261 PTService@slh.wisc.edu General Chemistry Ammonia/Ethanol - 5 x

More information

Plasma proteins Quantitatively, proteins are the most important part of the soluble components of the blood plasma.

Plasma proteins Quantitatively, proteins are the most important part of the soluble components of the blood plasma. Plasma proteins 42 Plasma proteins Quantitatively, proteins are the most important part of the soluble components of the blood plasma. concentrations of between 60 and 80 g L 1, they constitute approximately

More information

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1)

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1) 0086 LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1) CAT. NO. LAL 4213 LOT NO. 238UL SIZE: 12 x 5 ml EXPIRY: 2018-04-28 GTIN: 05055273209006 INTENDED USE This product

More information

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5 AFP All All < 15 ug/l Albumin All 0-3M 25-40 g/l Albumin All 3-12M 32-45 g/l Albumin All 1-70Y 34-48 g/l Albumin All >70Y 32-46 g/l Alk Phos All 0-10Y 80-350 U/L Alk Phos M 10-14Y 45-400 U/L Alk Phos F

More information

EDUCATIONAL COMMENTARY rd TEST EVENT Chemistry Urine Drug Testing

EDUCATIONAL COMMENTARY rd TEST EVENT Chemistry Urine Drug Testing EDUCATIONAL COMMENTARY 2003 3 rd TEST EVENT Chemistry Urine Drug Testing Educational commentary is provided through our affiliation with the American Society for Clinical Pathology (ASCP). To obtain FREE

More information

LABORATORY NORMAL RANGES. Prepared by Date Adopted Supersedes Procedure # / Dated William T. Pope, PhD and

LABORATORY NORMAL RANGES. Prepared by Date Adopted Supersedes Procedure # / Dated William T. Pope, PhD and Prepared by Date Adopted Supersedes Procedure # / Dated William T. Pope, PhD and 3-31-09 Normal Ranges / 12-30-08 Christy O Brien, MT (ASCP) CHEMISTRY Acetone None detected Albumin, g/dl 3.5-5.0 Adult

More information

You will receive an Advance Shipment Notice (ASN), which reminds you of upcoming shipments and test events, before

You will receive an Advance Shipment Notice (ASN), which reminds you of upcoming shipments and test events, before 2015 Test Event Calendar The following Test Event Calendar applies for all Programs in this section. The number of shipments of sample sets is indicated in the program description for each Program. You

More information

Clinical Chemistry Specific Proteins Presentation

Clinical Chemistry Specific Proteins Presentation Clinical Chemistry Specific Proteins Presentation November 2004 AEROSET and c8000 are registered trademarks of Abbott Laboratories. All other trademarks, brands, trade names and product names are the property

More information

klinikuri bioqimia kat. # dasaxeleba SefuTva

klinikuri bioqimia kat. # dasaxeleba SefuTva klinikuri bioqimia substratebi / Substrates 1001020 Albumin 2 x 250 ml 1001041 Bilirubin Total & Direct Jendrasik 1 x 150 ml 1001042 Total Bilirubin DMSO 2 x 150 ml 1001043 Direct Bilirubin DMSO 2 x 150

More information

PROGRAM General Information

PROGRAM General Information Association for Quality Assessment in TDM and Clinical Toxicology Section of the Dutch Foundation for Quality Assessment in Medical Laboratories PROGRAM 2016 General Information P.O. Box 43100, 2504 AC

More information

DELIVERS MORE EASY FAST EFFICIENT. Linearity and Calibration Verification PRODUCT CATALOG

DELIVERS MORE EASY FAST EFFICIENT. Linearity and Calibration Verification PRODUCT CATALOG DELIVERS MORE EASY FAST EFFICIENT Linearity and Calibration Verification PRODUCT CATALOG VALIDATE PRODUCTS ARE SYNONYMOUS WITH EFFICIENCY AND QUALITY. READY-TO-USE LINEARITY SETS: Liquid samples require

More information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information Daily Quality Control Calibration Verification / Linearity Quality control made easy. Product Information AUDIT MicroControls Making life in the lab easier. AUDIT provides value to customers through high-quality

More information

American Bio Medica Corporation (Updated 3/1/05) 122 Smith Road, Kinderhook NY NYS Contract PC SB

American Bio Medica Corporation (Updated 3/1/05) 122 Smith Road, Kinderhook NY NYS Contract PC SB Award Number 00155 Item # Description American Bio Medica Corporation (Updated 3/1/05) 122 Smith Road, Kinderhook NY 12106 www.abmc.com NYS Contract PC57927 - SB Qty/ Case or Package List Price/ Unit NYS

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-25 U/L 10-35 U/L 10-30 U/L 10-25 U/L 10-30 U/L 10-35 U/L 10-25 U/L 10-35 U/L 10-25 U/L 10-20 U/L 10-35 U/L Albumin 0-6

More information

EASY. FAST. EFFICIENT.

EASY. FAST. EFFICIENT. DELIVERS MORE EASY. FAST. EFFICIENT. Calibration Verification / Linearity Testing PRODUCT CATALOG VALIDATE PRODUCTS ARE SYNONYMOUS WITH EFFICIENCY AND PRECISION. READY-TO-USE LINEARITY SETS: Liquid samples

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-30 U/L 10-30 U/L 10-20 U/L Albumin 0-6 days 6 days - 37 months 37 months - 7 years 7-20 years 2.6-3.6 g/dl 3.4-4.2 g/dl

More information

Frequently Asked Questions: Opiate Dependency and Methadone Maintenance Treatment program follow-up

Frequently Asked Questions: Opiate Dependency and Methadone Maintenance Treatment program follow-up Frequently Asked Questions: Opiate Dependency and Methadone Maintenance Treatment program follow-up Dr. Bhushan M. Kapur Associate Professor Department of Laboratory Medicine and Pathobiology, Faculty

More information

Alere Triage System. Knowing now matters when rapid treatment decisions can be made at the point-of-care.

Alere Triage System. Knowing now matters when rapid treatment decisions can be made at the point-of-care. System Knowing now matters when rapid treatment decisions can be made at the point-of-care. The Alere Triage System The MeterPro is utilized in thousands of healthcare facilities worldwide. A comprehensive

More information

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L The highest quality range of routine DP PT Lp(a) CO 2 ApTT Cu Hp MAU and novel D3-HB reagents CH T Cu Hp MAU D3-HB CHE Li Na Zn TAS HDL L HFABP Apo A-1PHE EDDP PT Lp(a) CO 2 ApTT DP PT Lp(a) CO 2 ApTT

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE INSTRUCTIONS FOR USE VITROS Chemistry Products malb Reagent malb 680 1740 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry Products malb Reagent is used on the VITROS 5,1 FS Chemistry

More information

25 years of research excelence

25 years of research excelence Crystal Chem full product catalog 25 years of research excelence We're poud to be one of the top providers of research assays for the last 25 years product catalog See our full line of high quality assays

More information

LABHORIZONS. New Procedures A NEWSLETTER FOR CLIENTS

LABHORIZONS. New Procedures A NEWSLETTER FOR CLIENTS LABHORIZONS A NEWSLETTER FOR CLIENTS Volume XVII, No. 6 June 2017 New Procedures RheumAssure................................... 504509 CPT 83520; 86200; 86431 Synonyms 14-3-3; 14-3-3 η Protein; ACPA; Anti-CCP;

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Gender: M Chart No: Fasting: Yes. Boston Heart HDL Map TM Test 1 ApoA-I (mg/dl) levels in HDL particles. α Range > <14 mg/dl. α-2 50.

Gender: M Chart No: Fasting: Yes. Boston Heart HDL Map TM Test 1 ApoA-I (mg/dl) levels in HDL particles. α Range > <14 mg/dl. α-2 50. Pro vider: Ordering Provider 123 Main Street Anytown, ST 12345 Account No: DOB: 00/00/1950 Framingham Risk Score: Patient Info: FAMILY HIST CVD Lipid, Lipoprotein and Apolipoprotein Tests Total Cholesterol

More information

NEW RCPCH REFERENCE RANGES-

NEW RCPCH REFERENCE RANGES- s vary between populations and age groups and it is important to always check the reference Haematology: Haemoglobin Male 130 175 g/l 0 6 days 145-220 g/l Female 115 165 g/l 7 days 140-186 g/l 8 days 3

More information

TRACEABILITY and UNCERTAINTY 9

TRACEABILITY and UNCERTAINTY 9 AAT Antitrypsin alpha 1 AAGP Acid glycoprotein alpha 1 immunoturbidimetric Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Integra 00 plus Acid phosphatase,

More information

Biochemistry Adult Reference Ranges

Biochemistry Adult Reference Ranges Certified correct on 28/06/2016 Biochemistry Adult Reference Ranges Test Reference range Units Reference range from Traceable to standard reference material Albumin 35 50 g/l Pathology IRMM ERM-DA470k/IFCC

More information

Minimum Whole Blood Volumes for Microcollection Tubes for Neonates, Pediatrics, Patients less than 45 kg (100 lb) and Difficult Collections

Minimum Whole Blood Volumes for Microcollection Tubes for Neonates, Pediatrics, Patients less than 45 kg (100 lb) and Difficult Collections The following table outlines the minimum whole blood volume that must be drawn into a microcollection tube (unless otherwise stated) for an individual test on a neonate, pediatric, patient weighing less

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Biochemistry Department Poole Hospital Longfleet Road Poole BH15 2JB Contact: Dr Fergus Jack Tel: +44 (0) 1202 442 497 E-Mail: Fergus.jack@poole.nhs.uk

More information

Reference Manual. Performance Verification Manual. For In Vitro Diagnostic Use. This manual is intended for UniCel DxC Systems AU Systems

Reference Manual. Performance Verification Manual. For In Vitro Diagnostic Use. This manual is intended for UniCel DxC Systems AU Systems Reference Manual Performance Verification Manual For In Vitro Diagnostic Use This manual is intended for UniCel DxC Systems AU Systems PN A85514AC December 2016 Beckman Coulter, Inc. 250 S. Kraemer Blvd.

More information

Provided by MedicalStudentExams.com NORMAL LABORATORY VALUES

Provided by MedicalStudentExams.com NORMAL LABORATORY VALUES NORMAL LABORATORY VALUES 1. BLOOD, PLASMA, SERUM 2. CEREBROSPINAL FLUID 3. HEMATOLOGIC 4. SWEAT 5. URINE 6. SYNOVIAL FLUID 7. TOXIC LEVELS 8. Tumour Markers 9. Differential of Cerebral Spinal Fluid 10.

More information

DTH Meditech HCIS Reference Intervals

DTH Meditech HCIS Reference Intervals Applicability Purpose This document applies to all Central Zone DTH Meditech HCIS personnel of AHS Laboratory Services and laboratories administered under the Covenant Health Group collectively referred

More information

Contract No. 952-M1 Collection Service Requirements Texas Department of Criminal Justice (TDCJ)

Contract No. 952-M1 Collection Service Requirements Texas Department of Criminal Justice (TDCJ) The services and requirements referenced are specific to Texas Department of Criminal Justice (TDCJ) and are in addition to and may include the services and must be in compliance with the requirements

More information

Laboratory diagnosis of plasma proteins and plasma enzymes

Laboratory diagnosis of plasma proteins and plasma enzymes Laboratory diagnosis of plasma proteins and plasma enzymes Functions of plasma proteins Function: transport humoral immunity enzymes protease inhibitors maintenance of oncotic pressure buffering Example:

More information

BS-230. Clinical Chemistry Analyzer

BS-230. Clinical Chemistry Analyzer BS-230 Clinical Chemistry Analyzer Flexible loading: 80 sample positions, Up to 80 reagent positions. Up to (40 fixed + 40 interchangeable) μl minimum reaction volume Disposable Cuvettes to avoid contamination

More information

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp R E A G E N T S The highest quality range of routine and novel reagents DP PT Lp(a) C T Cu Hp MAU D3-HB HFABP Apo A-1PHE EDDP DP PT Lp(a) CO 2 ApTT Cu Hp u Hp MAU D3-HB CHE Li Na Zn ABP Apo A-1 PHE EDDP

More information

TARRANT COUNTY PURCHASING DEPARTMENT

TARRANT COUNTY PURCHASING DEPARTMENT JACK BEACHAM, C.P.M., A.P.P. PURCHASING AGENT TARRANT COUNTY PURCHASING DEPARTMENT JULY 20, 2015 BID NO. 2015-163 ADDENDUM #1 ROB COX, C.P.M., A.P.P. ASSISTANT PURCHASING AGENT ANNUAL CONTRACT FOR VARIOUS

More information

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens This document describes the validation of a Neogen Fentanyl kit for the semi-quantitative analysis of

More information

Rapid Alcohol Screening Devices. p19

Rapid Alcohol Screening Devices. p19 CLIA-WAIVED Product Catalog RAPID DRUG SCREENING DEVICES Rapid Urine Drug Screening Devices. p5 Rapid Alcohol Screening Devices. p19 Complementary Products. p23 HELPING YOU MAKE INFORMED DECISIONS ABOUT

More information

HOSPITALS IN-COMMON LABORATORY INC.

HOSPITALS IN-COMMON LABORATORY INC. Immunoglobulin E Ab., Single Allergen: Allergens are now searchable and viewable in the web test manual database but are not listed individually in the printable pdf-format documents. Trace Metals: Trace

More information

DAT-B 2015 Direct Antiglobulin Test

DAT-B 2015 Direct Antiglobulin Test EVALUATION DAT-B 2015 Direct Antiglobulin Test INSTITUTION: ATTENTION: CAP NUMBER: 7181660-01 Kit# 1 KIT INFORMATION: Kit ID: 28002258 10/12/2015 11/16/2015 Next Mailing Date: 2/22/2016 COPIED TO: LAP

More information

Quest Diagnostics Drug Testing Index Full Year 2015 Tables

Quest Diagnostics Drug Testing Index Full Year 2015 Tables Quest Diagnostics Drug Testing Index Full Year 2015 Tables Table 1. Annual Positivity Rates Urine Drug Tests (For Combined U.S. Workforce) (More than 9.5 million tests from January to December 2015) Year

More information

DrugSmartCup & DrugSmartDip Accuracy Report as produced by Ameditech, Inc.

DrugSmartCup & DrugSmartDip Accuracy Report as produced by Ameditech, Inc. Accuracy The accuracy of the DrugSmart Drugs of Abuse Tests was evaluated in comparison to commercially available drug screen tests. Sixty (60) negative urine samples collected from presumed non-user volunteers

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE VITROS Chemistry Products Reagent 680 1728 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry Products Reagent is used on the VITROS 5,1 FS Chemistry System, the VITROS 4600 Chemistry

More information

Test Definition: PCDSO Pain Clinic Drug Screen, Urine

Test Definition: PCDSO Pain Clinic Drug Screen, Urine Reporting Title: Pain Clinic Drug Screen, U Performing Location: Rochester Specimen Requirements: Collection Container/Tube: Plastic urine container Submission Container/Tube: Plastic, 60-mL urine bottle

More information

ONLINE DAT II Results matter.

ONLINE DAT II Results matter. From tough questions to reliable answers. ONLINE DAT II Results matter. Patient results matter Reputations are at stake: theirs and yours. Behind every Drugs-of-Abuse Test (DAT) result is a person whose

More information

Results that require action

Results that require action Following is a list of Allina Health Laboratory Results That Require Action (formerly Critical Values). Results That Require Action describes a lab test result that may indicate a lifethreatening situation.

More information

Test Definition: PDSOX Pain Clinic Drug Screen, Chain of Custody, Urine

Test Definition: PDSOX Pain Clinic Drug Screen, Chain of Custody, Urine Reporting Title: Pain Clinic Drug Screen, CoC, U Performing Location: Rochester Specimen Requirements: Container/Tube: Chain-of-Custody Kit (Supply T282) containing the specimen containers, seals, and

More information

1. Purpose 1.1. To define testing locations, schedule and order priority for each test performed in the core laboratory.

1. Purpose 1.1. To define testing locations, schedule and order priority for each test performed in the core laboratory. Department Of Pathology GEN.1017.03 Integrated Test Schedule Version# 5 Department Specimen Processing POLICY NO. 1938 PAGE NO. 1 OF 6 Printed copies are for reference only. Please refer to the electronic

More information

Roche/Hitachi - PreciControl ClinChem Multi 2

Roche/Hitachi - PreciControl ClinChem Multi 2 ATRYP Antitrypsin alpha 1 ERM-DA470k/IFCC 9 136 1.36 1.84 0.0184 GPROT Acid glycoprotein alpha 1 CRM 470 2 90.1 0.901 0.890 0.00890 ACP Acid phosphatase total 1-naphthyl phosphate 0.720 43.1 0.00703 0.421

More information

PENN STATE MILTON S. HERSHEY MEDICAL CENTER TABLE OF CRITICAL LAB VALUES CURRENT AS OF: 1/2015

PENN STATE MILTON S. HERSHEY MEDICAL CENTER TABLE OF CRITICAL LAB VALUES CURRENT AS OF: 1/2015 PENN STATE MILTON S. HERSHEY MEDICAL CENTER TABLE OF CRITICAL LAB VALUES CURRENT AS OF: 1/2015 Section: Chemistry For inpatients, once 3 consecutive critical values for the same analyte (test result) have

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 BIO-RAD LABORATORIES 9500 Jeronimo Road Irvine, CA 92618-2017 Regulatory Phone (Elizabeth Platt): 949 598-1285 US Product Info/Sales: Phone: (800) 224-6723,

More information

The Quidel Triage System

The Quidel Triage System The Quidel Triage System Automated. Calibrated. Connected. Professional diagnostics at the point-of-care BR1026500EN00.qxp_Layout 1 8/28/18 2:28 PM Page 4 The Quidel Triage System Fast quantitative results

More information

HAEMATOLOGY. Test Name Status Result Unit Reference Interval HbA1c (Glycated Haemoglobin) 5.4 % Method : HPLC Sample Type : Whole Blood EDTA

HAEMATOLOGY. Test Name Status Result Unit Reference Interval HbA1c (Glycated Haemoglobin) 5.4 % Method : HPLC Sample Type : Whole Blood EDTA Institution Report Date 25-Dec-2016 05:59 PM HAEMATOLOGY HbA1c (Glycated Haemoglobin) 5.4 % 4.5-6.0 Method : HPLC Sample Type : Whole Blood EDTA REMARKS In vitro quantitative determination of HbA1c in

More information

therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser

therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser The RX imola is a cost effective system that delivers consistent high quality results. Capable of

More information

Laboratory Values, Critical. ThedaCare. Date Last Reviewed: 4/5/2018 Reviewing Body(s): Quality; Laboratory Leadership

Laboratory Values, Critical. ThedaCare. Date Last Reviewed: 4/5/2018 Reviewing Body(s): Quality; Laboratory Leadership Laboratory Values, Critical ThedaCare Policy & Procedure Policy Title: Laboratory Values, Critical Policy Number: 694 Location(s): All ThedaCare Department(s): Laboratory Date Last Reviewed: 4/5/2018 Reviewing

More information

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS External Quality Assurance Services Table of Contents About Bio-Rad EQAS EQAS Program Overview.... 3 Online EQAS Resources... 4 Submitting

More information

Bio-Rad Laboratories EQAS. External Quality Assurance Services

Bio-Rad Laboratories EQAS. External Quality Assurance Services Bio-Rad Laboratories EXternal QUALITY ASSURANCE SERVICES EQAS External Quality Assurance Services Bio-Rad Laboratories EXternal QUALITY ASSURANCE SERVICES Participate in an internationally recognized quality

More information

Analyte Specimen Demographic Reference Range Units

Analyte Specimen Demographic Reference Range Units Acetone Negative titer Alanine aminotransferase (ALT/SGPT) 10-49 U/L Albumin 3.2-4.8 g/dl Alcohol < 10 Alpha-fetoprotein (AFP) < 1.3-8.1 ng/ml Alkaline phosphatase 0 7 days 7 30 days 1 3 3 6 6 12 1 3 3

More information

Urine Drug Testing to Monitor Opioid Use In Managing Chronic Pain

Urine Drug Testing to Monitor Opioid Use In Managing Chronic Pain Faculty Disclosure Henry C. Nipper, PhD, DABCC Dr. Nipper has listed no financial interest/arrangement that would be considered a conflict of interest. Urine Drug Testing to Monitor Opioid Use In Managing

More information

IMMUNOASSAY PREMIUM - LEVEL 3 (IA PREMIUM 3)

IMMUNOASSAY PREMIUM - LEVEL 3 (IA PREMIUM 3) 0086 IMMUNOASSAY PREMIUM - LEVEL 3 (IA PREMIUM 3) CAT. NO. IA2640 GTIN: 05055273203868 SIZE: 12 x 5 ml CAT. NO. IA2633 GTIN: 05055273203837 SIZE: 4 x 5 ml LOT NO. 1627EC EXPIRY: 2019-04-28 INTENDED USE

More information

Learning Objectives. Drug Testing 10/17/2012. Utilization of the urine drug screen: The good, the bad, and the ugly

Learning Objectives. Drug Testing 10/17/2012. Utilization of the urine drug screen: The good, the bad, and the ugly Utilization of the urine drug screen: The good, the bad, and the ugly Jennifer A. Lowry, MD Chief, Section of Medical Toxicology Children s Mercy Hospital Kansas City, MO Learning Objectives Describe the

More information

2013 Clinical drug and alcohol testing solutions. Product Catalog. CLIA-waived point of care test devices

2013 Clinical drug and alcohol testing solutions. Product Catalog. CLIA-waived point of care test devices 2013 Clinical drug and alcohol testing solutions Product Catalog CLIA-waived point of care test devices HELPING YOU MAKE INFORMED DECISIONS ABOUT ABUSE. Substance abuse testing with more substance. 2 of

More information

CLIA APPROVED PROFICIENCY TESTING PROGRAMS ACCUTEST, INC. P.O. Box 999 Westford, Massachusetts (800)

CLIA APPROVED PROFICIENCY TESTING PROGRAMS ACCUTEST, INC. P.O. Box 999 Westford, Massachusetts (800) ACCUTEST, INC. P.O. Box 999 Westford, Massachusetts 01886 (800) 665-2575 MICROBIOLOGY Bacteriology Aerobic Culture and Identification Antibiotic Susceptibility Testing Direct Antigen Detection Gram Stain

More information

PEACEHEALTH LABORATORIES

PEACEHEALTH LABORATORIES 360-414-2306 www.peacehealthlabs.org Critical Values Call List - Longview Critical values are reported per the criteria published below. Laboratory results meeting these criteria indicate potential life-threatening

More information