Operating Instructions SaHoMa -II mobile ultrasonic nebulizer
|
|
- Donald Gilmore
- 5 years ago
- Views:
Transcription
1 Operating Instructions SaHoMa -II mobile ultrasonic nebulizer
2 Manufacturer NEBU-TEC International med. Produkte Eike Kern GmbH Kreuzfeldring Elsenfeld GERMANY Tel.: (+49) (0) Fax: (+49) (0) sahoma@nebu-tec.de Web: Description SaHoMa -II mobile ultrasonic nebulizer Type: HM-200 Made in Germany SaHoMa -II Inhalation Mask Type: HM-210 Made in Germany Security Advice: Each handling of the device requires the exact understanding and observance of the present instruction manual. In any case, the liability for the safe functioning of the devices devolves solely to the user if intervention by third persons or handling not according to the intended use occur. Intended Use: In combination with the SaHoMa -II mobile ultrasonic nebulizer your SaHoMa -II Inhalation Mask applies highly efficient and accurately dosed medication into the respiratory cycle of your horse. Seite 2
3 Table of Contencts: Page: 1. How to operate the SaHoMa -II Inhalation Mask Connection of the fastening belt to the SaHoMa -II Inhalation Mask How to attach the sealing ring How to attach the SaHoMa -II Inhalation Mask Connection of the SaHoMa -II mobile ultrasonic nebulizer to the SaHoMa -II Inhalation Mask Connection of the SaHoMa -II nebulization unit to the SaHoMa -II mobile ultrasonic nebulizer Protection of the electronic part and the nebulization unit of the SaHoMa -II Inhalation Mask Connection of the filter membrane and filter basket to the SaHoMa -II Inhalation Mask How to turn on the ultrasonic nebulizer SaHoMa -II 9 2. Charging the SaHoMa -II mobile ultrasonic nebulizer Capacity check of the rechargeable battery pack Charging the SaHoMa -II mobile ultrasonic nebulizer Cleaning the Nebulization Unit Cleaning of the aerosol generator Cleaning of the medication chamber Drying the accessory parts of the nebulization unit Assembly of the nebulization unit Cleaning the Aerosol Generator with the SaHoMa Concentrated Detergent Filling the Nebulization Unit Technical Information Technical information SaHoMa -II mobile ultrasonic nebulizer Technical information SaHoMa -II Inhalation Mask Aerosol spectrum SaHoMa -II mobile ultrasonic nebulizer Average operating life of the components of the SaHoMa -II mobile ultrasonic nebulizer Display of the SaHoMa -II mobile ultrasonic nebulizer Troubleshooting Ambient conditions Storage and transportation conditions Warranty Warranty card Parts list 24 Seite 3
4 1. How to operate the SaHoMa -II Inhalation Mask 1.1 Connection of the fastening belt to the SaHoMa -II Inhalation Mask Connect the fastening belt (Art.-No.: HM-217) to the SaHoMa -II Inhalation Mask by plugging the two clips in the fastening bar of the inhalation mask. 1.2 How to attach the sealing ring Put he sealing ring (Art.-No.: HM-215) over the horse s snout so that it can get used to the upcoming inhalation treatment. Seite 4
5 1.3 How to attach the SaHoMa -II Inhalation Mask Now put the SaHoMa -II Inhalation Mask over the horse s snout and fit the sealing ring into the rear bulge of the inhalation mask. The horse can still breathe without inspiration resistance as both the filter basket and filter membrane have not been inserted yet. Now fasten the fastening belt at the back of the horse s head. Seite 5
6 1.4 Connection of the SaHoMa -II mobile ultrasonic nebulizer to the SaHoMa -II Inhalation Mask Slide the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) along the slide rails of the SaHoMa -II Inhalation Mask (Art.-No.: HM-210) into the opening. The SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) snaps into the SaHoMa -II Inhalation Mask (Art.-No.: HM-210) and thus guarantees a secure connection. Seite 6
7 1.5 Connection of the SaHoMa -II nebulization unit to the SaHoMa -II mobile ultrasonic nebulizer Now connect the connecting cable of the SaHoMa -II nebulization unit (Art.-No.: HM-201) to the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200). Connect the SaHoMa -II nebulization unit (Art.-No.: HM-201) to the SaHoMa -II Inhalation Mask (Art.- No.: HM-210). Fasten the nebulization unit as shown in the below picture in order to guarantee that no residual quantity is left in the nebulization unit after the nebulization process. Seite 7
8 1.6 Protection of the electronic part and the nebulization unit of the SaHoMa -II Inhalation Mask Slide the protective cover over both the electronic part and nebulization unit. 1.7 Connection of the filter membrane and filter basket to the SaHoMa -II Inhalation Mask Insert a new filter membrane (Art.-No.: HM-214) into the filter basket (Art.-No.: HM-212) of the SaHoMa -II Inhalation Mask. Gently slide the filter basket (Art.-No.: HM-212) with the inserted filter membrane (Art.-No.: HM-214) over the two bolts. The two bolts of the SaHoMa -II Inhalation Mask will snap into the lateral holes of the clip. Seite 8
9 1.8 How to turn on the ultrasonic nebulizer SaHoMa -II Turn on the ultrasonic nebulizer by pressing the start-up button for approx. 3 seconds via the side hole in the protective cover. The light bar is rotating from the left to the right side. The multifunctional light is permanently flashing green. Seite 9
10 2. Charging the SaHoMa -II mobile ultrasonic nebulizer To keep you mobile your SaHoMa -II mobile ultrasonic nebulizer is equipped with integrated battery cells. It also provides a display that shows the battery capacity. This enables you to check the remaining capacity at any time. General Advice: Please note that the integrated display will not work shortly after completion of the inhalation process or the displayed value is not reliable, respectively. This is due to the design of the rechargeable battery. A reliable value can be displayed after a period of approx. 1 hour. 2.1 Capacity detection of the rechargeable battery pack Shortly push the button of your SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200). The light bar in the display shows the battery capacity (approx. 3 seconds). If this value is below or equal 20 % we recommend to charge the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200). Seite 10
11 2.2 Charging the SaHoMa -II mobile ultrasonic nebulizer Connect the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) to the power cord (Art.-No. HM- 204) and a power socket. The flashing green indicator light signals the charging process. When the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) is completely charged the indicator light is continuously lit (green light). Attention: Do only use the original power cord (Art.-No.: HM-204) for charging the SaHoMa -II mobile ultrasonic nebulizer. Do not use a damaged or defective power cord. Contact the manufacturer immediately if the device is defective. Seite 11
12 3. Cleaning the Nebulization Unit 3.1 Cleaning of the aerosol generator Open the nebulization unit (Art.-No. HM-201) by pushing the blue button and turning the bottom down. Now you can remove the aerosol generator carefully from the nebulization unit (HM-201). Please only touch the aerosol generator at tis frame and be careful not touching the metal membrane. Rinse the aerosol generator under tap water. Seite 12
13 3.2 Cleaning of the medication chamber Open the cap and bottom of the nebulization unit. Never pull directly at the cable as this could cause cable breaks and device failures. Rinse the nebulization unit under running tap water. Important note: Please make sure that the cable with its plug don t get wet. (Danger of short circuit) Seite 13
14 3.3 Drying the accessory parts of the nebulization unit Place all cleaned accessory parts of the nebulization unit on a clean, dry and absorbent surface and let them air-dry completely. Note: If you intend to apply different medications successively during your inhalation therapy, please note the following: After each application the nebulizer needs to be rinsed under warm tap water until the medicine residues are completely removed so that undesirable interaction amongst the medicine residues can be avoided. The aerosol generator is a wearing part and must be replaced depending on the time of usage, but in any case at least after 6 months. Seite 14
15 3.4 Assembly of the nebulization unit Open the bottom of the nebulization unit. Now insert the aerosol generator into the nebulization unit. Please only touch the aerosol generator at its frame and be careful not touching the metal membrane. The aerosol generator clicks into place when inserting it. The nebulization unit is now ready for the next application. It needs to be stored and assembled condition. Seite 15
16 4. Cleaning the aerosol generator with the SaHoMa concentrated detergent The SaHoMa unit may only be cleaned using the concentrated detergent provided by the manufacturer. The unit needs to be cleaned when the performance of the aerosol generator is considerably decreasing. For opening and cleaning the SaHoMa -II nebulization unit please follow the information in Chapter 3 Cleaning the Nebulization Unit. IMPORTANT: THE CONCENTRATED DETERGENT MAY NOT BE INHALED! ATTENTION: Always arrange for adequate ventilation! Proceed as follows when using the SaHoMa concentrated detergent: 1. Fill the medication chamber with the SaHoMa -II concentrated detergent. 2. Have the SaHoMa -II concentrated detergent nebulized for 1 minute. ATTENTION: Always arrange for adequate ventilation! IMPORTANT: THE CONCENTRATED DETERGENT MAY NOT BE INHALED! 3. Leave the detergent in the medication chamber for 3 minutes. 4. Now have the SaHoMa -II concentrated detergent completely nebulized. ATTENTION: Always arrange for adequate ventilation! IMPORTANT: THE CONCENTRATED DETERGENT MAY NOT BE INHALED! 5. Now rinse the nebulization unit thouroughly with warm tap water (at least 1 minute). 6. Then have 3 ml distilled (demineralitzed) water nebulized. NOTE: Please arrange for adequate ventilation at any time when having the SaHoMa -II concentrated detergent nebulized. IMPORTANT: THE CONCENTRATED DETERGENT MAY NOT BE INHALED! Seite 16
17 5. Filling the nebulization unit Open the cap of the nebulization unit and fill in the medication/solution by using a syringe, ampoule, etc. Please note that the maximum filling quantity is 18 ml. Afterwards close the cap of the nebulization unit. Seite 17
18 6. Technical information 6.1 Technical information SaHoMa -II mobile ultrasonic nebulizer Type:. HM-200 Description:.....SaHoMa -II mobile ultrasonic nebulizer Dimensions basic device (L x W x H): x 85 x 70 mm Weight basic device: g Power supply:...battery operation Power cord: VDC / 1.5 A Ultrasonic frequency: khz Nebulization output: ml/min Volumetric capacity of nebulization unit ml Electrical protection class IIB Type:. HM-203 Description:...nebulization unit Dimensions (L x W x H): x 50 x 60 mm Weight: g 6.2 Technical information SaHoMa -II Inhalation Mask Type:.HM-210 Dimensions mask (L x W x H): x 250 x 325 mm Weight mask: g Material data sheet: GRILAMID Seite 18
19 6.3 Aerosol spectrum SaHoMa -II mobile ultrasonic nebulizer The aerosol characteristics were determined by means of a HELOS VARIO KF laser diffractometer. Test medium: 0.9 % sodium chloride (NaCl). 6.4 Average operating life of the components of the SaHoMa -II mobile ultrasonic nebulizer: Nebulization unit for SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-201).12 months Aerosol generator... maximum 6 months After the expiration of the operating life we recommend to replace the components in order to guarantee a proper functioning. The components need to be replaced earlier if the nebulization time increases although using the same solution and same volume as usual. Seite 19
20 6.5 Display of the SaHoMa -II mobile ultrasonic nebulizer Display of battery capacity: Shortly push the button of your SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200). The battery capacity is displayed for approx. 3 secs. Start of nebulization process: Push the button of the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) for 3 secs. This initiates the nebulization (rotating light bar from left to right together with flashing green light). End of nebulization: When the medication is completely nebulized the light bars in the display move from the middle to both sides (left/right). Nebulization unit is not connected: If you push the button of the SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) and the nebulization unit is not connected the following is displayed: The light bar is continuously lit and the multifunction light is successively flashing red/green. Seite 20
21 6.6 Troubleshooting No function red light bar on the left side: Device has not function. The light bar is on the left side, is continuously flashing and the multifunctional light is successively flashing red/green. Defective connection cable, cable break. Please replace nebulization unit (HM-201). No function red ligth bar on the right side: Device has no function. The light bar is on the right side, is continuously flashing and the multifunctional light is successively flashing red/green. Defective aerosol generator. Please replace the aerosol generator (HM-205). Problem Possible cause/troubleshooting Prolonged inhalation time - Has the aerosol generator been hygienically processed according to chapter 4? - Has the aerosol generator been mechanically damaged or is the operating life exceeded? The treatment times can differ from the stated values for specific medications. Low or no aerosol output below an ambient temperature of 15 C - The ambient temperature should be at least 15 C. - Please wait for about 30 minutes until the device is adapted to the ambient temperature. The medication should be temperated at room temperature. Seite 21
22 6.7 Ambient conditions The aerosol characteristic can be guaranteed if the following ambient conditions are kept: Ambient temperature...15 C - 35 C Relative humidity of ambient air...30 % - 95 % The medication to be nebulized must be temperated at room temperature. The aerosol spectrum can not be guaranteed if the relative humidiy of ambient air is too low (< 30%). 6.8 Storage and transportation conditions Temperature - 20 C to + 60 C Relative humidity of ambient air...15 % - 95 % The parts may not be exposed to direct sunlight. The nebulization unit, SaHoMa -II mobile ultrasonic nebulizer basic device and power cord may not be stored in damp locations and/or transported together with damp objects. When the ambient temperature is extremely fluctuating the efficacy of the device might be affected due to condensation humidity. 7. Warranty We issue a 24 months warranty on your SaHoMa -II Inhalation Mask (Art.-No.: HM-210) and SaHoMa -II mobile ultrasonic nebulizer (Art.-No.: HM-200) starting from date of purchase. The integrated battery cells have a warranty period of 6 months. Any damage caused by improper handling is not subject to warranty protection. The warranty expires when the device had been interfered with by a third party. Wearing parts of the SaHoMa -II mobile ultrasonic nebulizer, such as the nebulization unit or aerosol generator, are not subject to warranty protection. Wearing parts of the SaHoMa -II Inhalation Mask, such as filter membrane or sealing ring, are not subject to warranty protection. Seite 22
23 7.1 Warranty Card Warranty Card SaHoMa -II mobile ultrasonic nebulizer Type: HM-200 Date of Purchase: Serial Number: SaHoMa -II Inhalation Mask Type: HM-210 Date of Purchase: Owner: Name: Address: Country: Seite 23
24 8. SaHoMa -II Parts list Article-No.: HM-200 HM HM-201 HM-204 HM-205 HM HM HM HM-212 HM-213 HM-214 HM-215 HM-216 HM-217 HM-218 HM-230 HM-231 HM-232 HM-233 Description: SaHoMa -II mobile ultrasonic nebulizer SaHoMa -II mobile ultrasonic nebulizer incl. nebulization unit & power cord SaHoMa -II nebulization unit SaHoMa -II power cord SaHoMa -II aerosol generator for nebulization unit SaHoMa -II Inhalation Mask incl. fastening belt, filter basket, sealing ring, 5 filter membranes & carrying box SaHoMa -II housing bowl SaHoMa -II cap SaHoMa -II filter basket SaHoMa -II filter membrane with valves SaHoMa -II filter membrane SaHoMa -II sealing ring SaHoMa -II sealing ring small for foals SaHoMa -II fastening belt SaHoMa -II carrying box SaHoMa -II concentrated detergent for SaHoMa -II aerosol generator PYH-2800 Inhalation solution for SaHoMa -II 15-days-cure for galoppers PYH-2800 Inhalation solution for SaHoMa -II 15-days-cure for dressage riders PYH-2800 Inhalation solution for SaHoMa -II 15-days-cure for show jumbers NEBU-TEC International med. Produkte Eike Kern GmbH Kreuzfeldring Elsenfeld GERMANY Tel.: (+49) (0) Fax: (+49) (0) sahoma@nebu-tec.de Web: Seite 24
Portable Equine Nebuliser System. User Manual
Portable Equine Nebuliser System User Manual Table of Contents INTENDED USE... 3 SAFETY INFORMATION... 3 TECHNICAL SPECIFICATION... 4 INSTRUCTIONS FOR USE... 6 MAINTENANCE... 12 TROUBLESHOOTING... 13 WARRANTY...
More informationCompressor Nebulizer Instruction Manual Part No.: 5055
Compressor Nebulizer Instruction Manual Part No.: 5055 DISTRIBUTED BY: SAVE THESE INSTRUCTIONS. CAUTION - U.S. Federal Law restricts this device to sale by or on the order of a physician. 666002-6310 V1.3
More informationPORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606
PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606 Please read this guidebook carefully before operating this unit. Your Nebulizer is intended for use in the treatment of asthma, COPD and
More informationA82-LIFE-Dog Nebulizer NBB02
A82-LIFE-Dog Nebulizer NBB02 פיית אוויר A82-LIFE-Dog Nebulizer NBB02 www.mfcl.co.il COMPRESSOR NEBULIZER USER S MANUAL A82-LIFE-Dog Nebulizer NBB02 ILLUSTRATION OF PARTS A. NEBULIZER COMPRESSOR
More informationMini-Mist. Owner s Manual. portable nebulizer. PMM241 Rev.3 12/10
Mini-Mist TM portable nebulizer PMM241 Rev.3 12/10 Dear Prodigy Owner: Thank you for choosing the Prodigy Mini-Mist vibrating mesh nebulizer. Please read this manual carefully as it contains important
More informationCompressor Nebulizer. Guidebook
NSTRU Compressor Nebulizer Guidebook MODEL: MQ6002 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Compressor Nebulizer MODEL NO: MQ6002 INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------
More informationDear HighQ Check System Owner :
Dear HighQ Check System Owner : Thank you for purchasing the HighQ Check Blood Glucose Monitoring System. This manual provides important information to help you to use the system properly. Before using
More informationINSTRUCTIONS FOR USE WARNING
INSTRUCTIONS FOR USE WARNING Read and understand these Instructions for Use and all safety precautions it contains. Improper use can cause serious or fatal injury and/or illness. CAUTION US Federal law
More informationMedescan Nebuliser Med - S600A Instructions Manual
Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory
More informationMESH NEBULIZER INSTRUCTION MANUAL. Model NE-U22
EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 1 INSTRUCTION MANUAL MESH NEBULIZER Model NE-U22 Thank you very much for purchasing OMRON Mesh Nebulizer. Be sure to read this Instruction Manual before using the
More informationCompressor Nebulizer. Guidebook
NSTRU Compressor Nebulizer Guidebook MODEL: CN02WS (MQ6003) READ ALL INSTRUCTION BEFORE USE Airial TM Compressor Nebulizer INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------
More informationEnglish. Fealite Nasal Pillows System. User Manual
Fealite Nasal Pillows System User Manual 0123 Table of Contents Fealite Nasal Pillows System 1 Intended Use 1 Medical Information 1 Parts of the Fealite 3 Fitting the Fealite 5 Using Tube Retainer (Optional)
More informationInstruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C
Instruction Manual 2004 Aerogen, Inc. Part No. AG-AL1010 Rev. C Table of Contents Introduction... 3 System description... 4 Warnings... 5 Cautions... 5 Electromagnetic Susceptibility... 5 Symbols... 6
More informationMultipower. User Guide E S S E N T I A L S T R E N G T H
E L E M E N T E S S E N T I A L S T R E N G T H User Guide The identification plate of and manufacturer, affixed to the frame behind the barbell rack, gives the following details: A B C D E Name and address
More informationNebu 100s Series. Instruction Manual
Nebu 100s Series Instruction Manual Pioneer Medical Instrument Technology (PMI) Co.,Ltd. 7F., No.11, Wuquan 2nd Rd., Wugu Dist., New Taipei City 248, Taiwan R.O.C.) http://www.pmi med.com e Mail: customer.service@pmi
More informationInduction loop EZT Instruction manual
Induction loop EZT 3012 Instruction manual Important safety instructions Please read this instruction manual carefully and completely before using the product. Make this instruction manual easily accessible
More informationCOMPRESSOR NEBULIZER MODEL: JB USER S MANUAL
COMPRESSOR NEBULIZER MODEL: JB0112-062 USER S MANUAL Read this manual before operating the nebulizer Save these instructions for future reference Caution: Federal law restricts this device to sale by or
More informationPilotOne II. User Guide
PilotOne II User Guide Contents 1. Welcome 4 2. Description 5 3. Using Phonak PilotOne II 6 3.1 Inserting a new battery 6 3.2 Switching On / Off 7 3.3 Holding correctly 7 3.4 Changing hearing aid volume
More informationRecharge. Relax.Repeat.
Recharge. Relax.Repeat. Recharge. Relax.Repeat. What s Inside Your rechargeable hearing aids will be delivered to you in two boxes. Please note that both ZPower rechargeable batteries and disposable batteries
More informationPROFESSIONAL CARE OXYJET air. powered. Downloaded from manuals search engine. filter. OxyJet
PROFESSIONAL powered CARE by OXYJET+ 3000 600 500 air filter 5 400 300 200 ml OxyJet 6 English 9 KR If you should require further assistance, please call our Consumer Service line. Helpline GB 0 800 783
More informationTHE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT
USER MANUAL THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT 3 QUICK START GUIDE For those familiar with e-cigarettes, the steps below
More informationSelectTech 3.1 Bench Assembly / Owner s Manual
SelectTech 3.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Congratulations on your commitment to fitness and your purchase of the Bowflex SelectTech 3.1
More informationLow Row. User manual E S S E N T I A L S T R E N G T H
E L E M E N T E S S E N T I A L S T R E N G T H User manual 1 The identification plate of and manufacturer, affixed on the back panel of the weight stack, gives the following details: A B C D E Name and
More informationmax airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!
Operating Manual for max airless Dispenser Read this manual thoroughly before operating the Labmax airless! witeg Labortechnik GmbH Am Bildacker 16 D-97866 Wertheim/Main Phone: +49 (0)9342 / 9301-0 Fax:
More informationTH Premium RIC LI 19. Guide for Hearing Care Professionals
TH Premium RIC LI 19 Guide for Hearing Care Professionals Content Introduction 3 Before and after fitting 4 Assembling 4 Activating 4 Charging 5 Connecting 5 Noting the serial number 6 Replacing the housing
More informationRhino Clear Sprint Atomizer
Visit us online to view our wide range of sinus therapy medications for use with the Rhino Clear Sprint atomizer. www.woodlandhillspharmacy.com 20631 Ventura Blvd, Ste 305 Woodland Hills, CA 91364 Phone:
More informationTable of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5
User Manual 3 Table of Contents Introduction....4 1. Indications For Use...4 2. Contraindications...4 3. Warnings...5 4. Precautions...5 5. Adverse Reactions...5 6. Step-By-Step Instructions...6 A. Contents...6
More informationTWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL
TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact:
More informationPhonak PilotOne II. User Guide
Phonak PilotOne II User Guide Contents 1. Welcome 4 2. Description 5 3. Using Phonak PilotOne II 6 3.1 Inserting a new battery 6 3.2 Switching On/Off 7 3.3 Holding PilotOne II 7 3.4 Changing hearing aid
More informationCompatible with the following products TENS. Replacement Pads. User Manual. Last revised: V Last revised: V
Compatible with the following products TENS Replacement Pads User Manual Last revised: V11-160923 Last revised: V4-170619 Contents Introduction 2-3 Parts 3 General Warnings and Safety 4-10 Using your TENS
More informationCROSS TRAINING MAGNETIC TREADMILL
CROSS TRAINING MAGNETIC TREADMILL SF-T7615 USER MANUAL IMPORTANT : Read all instructions carefully before using this product. Retain this manual for future reference. For customer service, contact support@sunnyhealthfitness.com
More informationINSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.
INSTALLATION MANUAL VIDEO Camera, Probe and Lightsource OTOSCOPES www.medrx-int.com Contents Using The Video Otoscope... 3 The Battery Operated LED Light Source... 4 Wiring Diagram - Battery Operated LED
More informationCompressor Nebulizer System
MedPro The Professional Choice Le choix des professionnels MedProTM MC Compressor Nebulizer System 705-445 Instruction Manual Index 1. Introduction...2 2. Product Identification...2 3. Important Safeguards...3
More informationDip Station G
Exclusively distributed by: RFE UK Ltd The Performance Centre Maidstone Road Kingston, Milton Keynes MK 0BD, UK +44 (0)190 793020 sales@goldsgymfitness.com 20. All rights reserved. Manufactured under license
More informationSelectTech 4.1 Bench. Assembly Manual
SelectTech 4.1 Bench Assembly Manual Table of Contents Important Safety Instructions...3 Safety Warning Labels and Serial Number...4 Specifications...5 Before Assembly...5 Parts...6 Hardware...7 Tools...7
More informationCustom instruments. Insio primax User Guide. Hearing Systems
Custom instruments Insio primax User Guide Hearing Systems Content Welcome 4 Your hearing instruments 5 Instrument type 5 Getting to know your hearing instruments 5 Components and names 6 Controls 8 Settings
More informationweight.detach/bench ITEM NO: 76310
weight.detach/bench ITEM NO: 76310 OWNER S MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference. The specifications of this product
More informationThis page has been intentionally left blank
Instruction Manual Table of Contents Introduction... 1 Important Safeguards... 2 Warranty... 5 Classifications and Markings... 6 Aeroneb Go System Parts... 7 Unit Assembly and Usage... 7 Prior to Assembly...
More informationTWIST STEPPER NO. 045
TWIST STEPPER NO. 045 IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact: support@sunnyhealthfitness.com
More informationMANUAL. Initial owner
MANUAL Model S1club Initial owner On behalf of BIOROWER ROWING MACHINES we would like to congratulate you on becoming part of a new generation of rowers. Enclosed you will find important guidelines regarding
More informationGlucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only
Glucose Meter User Guide Veterinary Monitoring System For dog and cat use only Gpet instruction Manual 31/5/09 18:06 Page 2 Gpet instruction Manual 31/5/09 18:06 Page 3 TABLE OF CONTENTS Your g-pet system
More informationTABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION
TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION
More informationINSTRUCTION MANUAL. Compressor Nebulizer System NE-C25
INSTRUCTION MANUAL Compressor Nebulizer System Model NE-C25 Thank you very much for purchasing the OMRON product. Be sure to read this Instruction Manual thoroughly before use. Keep this Instruction Manual
More informationInstruction Manual for minivap Vaporizer. By HERMES Medical Engineering SL.
Instruction Manual for minivap Vaporizer By HERMES Medical Engineering SL. For correct use of device, please read the following document carefully. The user is not authorized to use the device outside
More informationOTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction
OTAGO LIPOSURG Compact, powerful system for infiltration and liposuction The Otago LipoSurg is the first medical device which allows infiltration and Liposuction in a single compact device. FEATURES AND
More informationER75 Electro-Acoustic Ear Simulator. Operating Manual
ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United
More informationTWISTING STAIR STEPPER WITH BANDS
TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN
More informationLIFEBOX TROUBLESHOOTING. Tips and hints
LIFEBOX TROUBLESHOOTING Tips and hints 2012 Lifebox Foundation. Registered as a charity in England and Wales (1143018). 1 About this guide Your Lifebox pulse oximeter was specially designed by experts
More informationGlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System
GlucCell TM SYSTEM USER S GUIDE ver 2.3 Intended Use The GlucCell TM Cell Culture Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during
More informationSelectTech 4.1 Bench Assembly / Owner s Manual
SelectTech 4.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Table of Contents Important Safety Instructions...3 Safety Warning Labels and Serial Number...4
More informationDr FuelCell Load Measurement Box
1 (855) 251-0016 sales@fuelcellstore.com Dr FuelCell Load Measurement Box Instruction Manual www.fuelcellstore.com Instruction Manual for Dr FuelCell TM Load Measurement Box Version 1.0.1 November 2008
More informationThe Omicron vaporizer is the world s first and only non-flame powered
The Omicron vaporizer is the world s first and only non-flame powered portable extract vaporizer. The only one to use pure extract oils with no need for carrier agents or cotton in the cartridge. The only
More informationBODY ANALYZER SCALE PS 8710
02PS8710_en 20.10.2008 13:30 Uhr Seite 14 Safety Please note the following instructions when using the appliance. 7 The appliance is designed for domestic use only. 7 Do not use the appliance on a carpet
More informationExclusively distributed by: RFE UK Ltd The Performance Centre Maidstone Road Kingston, Milton Keynes MK10 0BD, UK +44 (0)1908 793020 sales@goldsgymfitness.com www.goldsgymfitness.com 2010. All rights reserved.
More informationUTILITY TRAINER. Model STB Retain This Manual for Reference OWNER'S MANUAL
NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Important Assembly Information UTILITY TRAINER STB-98010 Care and Maintenance Parts List Warranty
More informationHCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual
HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT Instruction Manual TABLE OF CONTENTS IEC Symbols...2 Important Safeguards...2 Introduction...3 Specifications...4
More informationMARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL
NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Hardware Identifier MARCY DIAMOND ELITE UTILITY BENCH MD-440 Assembly Instruction Parts List Warranty
More informationAdjustable Ab Board G
Exclusively distributed by: RFE UK Ltd The Performance Centre Maidstone Road Kingston, Milton Keynes MK10 0BD, UK + (0)10 73020 sales@goldsgymfitness.com 2010. All rights reserved. Manufactured under license
More informationGlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System
GlucCell TM SYSTEM USER S GUIDE Ver 2.1 Intended Use The GlucCell TM Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during cell culture.
More informationBands. Model : No For Customer Service, please contact:
Twisting ing Stair Stepper With Bands Model : No. 068 For Customer Service, please contact: support@sunnyhealthfitness.com Important Safety Information We thank you for choosing our product. To guarantee
More informationComfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use
Comfortmax Thermax Hot/Cold Water Circulation System Instructions for Use THIS DEVICE CAN BE COLD ENOUGH TO CAUSE SERIOUS INJURY. SERIOUS ADVERSE REACTIONS AND SAFETY HAZARDS MAY OCCUR WHEN USING THIS
More informationE L E C T R O N I C VA P O R I Z E R S. User Manual
E L E C T R O N I C VA P O R I Z E R S User Manual Thank you for purchasing a Signature Series Product. Please read this manual carefully before use so as to use correctly. If you require additional information
More informationOWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:
OWNER S MANUAL BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio 43035 Tel: 800.990.5556 1 www.bodycraft.com SAFETY INSTRUCTION WARNING: To reduce the risk of serious injury, read the following safety
More informationBlood Glucose Monitoring System. User Guide
Blood Glucose Monitoring System User Guide Table of Contents Introduction...2 Important Safety Instructions...2 About ipet PRO Blood Glucose Monitoring System...3 About ipet PRO Meter...4 About the ipet
More informationHome Sleep Test. User Manual. One Night Test. For help at any time, call Also, please visit to watch our video.
Home Sleep Test User Manual For help at any time, call 1-877-753-3776. Also, please visit www.novasom.com to watch our video. One Night Test Before You Begin Before You Begin The AccuSom unit: cannot be
More informationWEIGHT SYSTEM EXERCISER User s Manual
Model No. 831.14934.0 Serial No. Write the serial number in the space above for reference. WEIGHT SYSTEM EXERCISER User s Manual Serial Number Decal Assembly Operation Maintenance Part List and Drawing
More informationE. SelectTech 3.1 Bench Assembly / Owner s Manual
000-6190.121212.E SelectTech 3.1 Bench Assembly / Owner s Manual Congratulations on your commitment to fitness and your purchase of the Bowflex SelectTech 3.1 Bench. Before assembling your Bowflex SelectTech
More information> Cue vaping device. > One e-liquid cartridge. > USB charging cord. > One Buddy Tip for sharing CUE. > This Quick Start Guide
What s in the box? > Cue vaping device > One e-liquid cartridge > USB charging cord > One Buddy Tip for sharing CUE > This Quick Start Guide Getting started y Charge the CUE device When the light turns
More informationCompact Compressor Nebulizer
INSTRUCTION MANUAL Compact Compressor Nebulizer MODEL NE-C30 3 5 ESPAÑOL PORTUGUÊS Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner
More informationBreezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler
Breezhaler 3 Pull cap off Press buttons once and release Breathe in rapidly and steadily. Hold. Open. Place capsule in chamber. Close (click). Breathe out 4 Open to see clear capsule. If not all clear
More informationPedAlert 100. PedAlert 120
PedAlert 100 & PedAlert 120 Operator s Manual 1996 PLANET LLC, Patent #6,174,294, B1 Notice: The manufacturer reserves the right to make changes to the device and Operator s Manual without obligation to
More informationOwner s Manual. Model# IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference.
Swing Stepper Owner s Manual Model#91306 IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference. The specifications of this product may vary
More informationTranscutaneous Electrical Nerve Stimulator (TENS)
Transcutaneous Electrical Nerve Stimulator (TENS) How does TENS work? A TENS unit sends electrical pulses through the skin to start your body s own pain killers. The electrical pulses can release endorphins
More informationBlood glucose monitor. MediTouch 2
Blood glucose monitor for self-testing MediTouch 2 Quick Reference Guide GB Art. 79034 0483 EXACT MDD 93/42/EWG WARNING Before using the MediTouch 2 blood glucose monitor from MEDISANA for the first time,
More informationTranscutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T
Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T Operation Manual Read Before Using GF-3-INS-LAB-RevA08 TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS
More informationUSER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at. or call
Model No. RBBE950 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal (Under Seat) QUESTIONS? As a manufacturer, we are committed to providing
More informationPLUS One. Blood Glucose Monitoring System. Owner s Manual
PLUS One Blood Glucose Monitoring System Owner s Manual Dear PLUS One System Owner: Thank you for purchasing the PLUS One Blood Glucose Monitoring System. This manual provides important information to
More informationGoniometer series 400
User s Manual Huber Diffraktionstechnik GmbH & Co. KG Sommerstrasse 4 D - 83253 Rimsting Phone +49 (0) 8501 6878-0 Fax +49 (0) 8051 6878-10 info@xhuber.com www.xhuber.com series 400 Manual 400_en-A05 2005
More informationExclusively distributed by: RFE UK Ltd The Performance Centre Maidstone Road Kingston, Milton Keynes MK10 0BD, UK +44 (0)1908 793020 sales@goldsgymfitness.com www.goldsgymfitness.com 2010. All rights reserved.
More informationAva Fertility Tracker User Manual Version 5.0. Not for contraceptive use.
Ava Fertility Tracker User Manual Version 5.0 Not for contraceptive use. 06 AVA AG, all rights reserved. Ava and Ava logotype are trademarks of Ava AG. All other trademarks are property of their respective
More informationAva Fertility Tracker User Manual Version 4.0. Not for contraceptive use.
Ava Fertility Tracker User Manual Version 4.0 Not for contraceptive use. 06 AVA AG, all rights reserved. Ava and Ava logotype are trademarks of Ava AG. All other trademarks are property of their respective
More informationTH Premium IF 19. User Guide
TH Premium IF 19 User Guide Content Welcome 4 Your hearing instruments 5 Instrument type 5 Getting to know your hearing instruments 5 Components and names 6 Hearing programs 7 Features 7 Batteries 8 Battery
More informationMotorised Treadmill Model No: JI1625
BODYWORX Motorised Treadmill Model No: JI1625 Retain this owner s manual for future reference Read and follow all instructions in this owner s manual Version A 1 TABLE OF CONTENTS OVERVIEW DRAWING 2 ASSEMBLY
More informationUSER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!
Model No. WEBE44.0 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal QUESTIONS? As a manufacturer, we are committed to providing complete customer
More informationE. SelectTech 5.1 Bench Owner s / Assembly Manual
000-6189.080118.E SelectTech 5.1 Bench Owner s / Assembly Manual Congratulations on your commitment to fitness and your purchase of the Bowflex SelectTech 5.1 Bench. Before assembling your Bowflex SelectTech
More informationTJF-160F/VF Cleaning and Disinfection Checklist
TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-160F/VF has been performed
More informationFibrlok II 2529 Universal Optical Fiber Splice
Fibrlok II 2529 Universal Optical Fiber Splice Instructions January 2007 78-8128-0163-3-E Contents: 1.0 General... 3 2.0 Splicing Set-up... 4 3.0 Fiber Preparation... 5 4.0 Splice Assembly... 6 5.0 For
More informationUser s Guide 2004 Horizon Fitness Products Designed & Engineered in the U.S.A. Made in China
VersaBALL_Pro_User s_guide_v1.0.qxd 8/20/2004 10:26 AM Page 1 HORIZON FITNESS 800 BURTON BOULEVARD DEFOREST, WI 53532 Phone 1-800-244-4192 Fax 1-608-842-1660 www.horizonfitness.com User s Guide Functional
More information38IN MINI TRAMPOLINE OWNER S MANUAL CAUTION MODEL NO Assembly Adjustments Parts Warranty
OWNER S MANUAL MODEL NO. 1231040 Assembly Adjustments Parts Warranty 38IN MINI TRAMPOLINE CAUTION You must read and understand this owner s manual before operating unit. SAFETY PRECAUTIONS Thank you for
More informationCompressor Nebulizer. Model UN-014
Compressor Nebulizer Model UN-014 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione ITALIANO ESPAÑOL FRANÇAIS ENGLISH 1WMPD4003398
More informationPARI INSTRUCTIONS FOR USE COMPRESSOR NEBULIZER SYSTEM. Portable Power Kit (optional)
PARI COMPRESSOR NEBULIZER SYSTEM INSTRUCTIONS FOR USE max Portable Power Kit (optional) max Multi-Voltage AC Adapter Power Cord Tubing Carrying Case max PARI Reusable Nebulizer PARI COMPRESSOR NEBULIZER
More informationThe Bowflex Conquest Home Gym Assembly Instructions
The Bowflex Conquest Home Gym Assembly Instructions P/N 001-6841 Rev C (04/2007) Table of Contents Before You Start... 2 Tools You Will Need / Hardware Chart... 3 Parts List... 4 Weight and Multi-carton
More informationDELUXE HOME GYM HG Model HG Retain This Manual for Reference OWNER'S MANUAL
NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Important Assembly Information DELUXE HOME GYM HG 8250 Care and Maintenance Parts List Warranty Ordering
More informationPure 312 Nx, Pure 13 Nx
Pure 312 Nx, Pure 13 Nx User Guide Hearing Systems Content Welcome 4 Your hearing instruments 5 Instrument type 5 Getting to know your hearing instruments 6 Components and names 7 Controls 10 Hearing programs
More informationROWER-442 ROWING MACHINE OWNER S MANUAL
ROWING MACHINE OWNER S MANUAL Product may vary slightly from the item pictured due to model upgrades Read all instructions carefully before using this product. Retain this owner s manual for future reference.
More informationVarseoWax CAD/Cast GEBRAUCHSANWEISUNG INSTRUCTIONS FOR USE MODE D EMPLOI INSTRUCCIONES DE USO ISTRUZIONI PER L USO Partners in Progress
www.bego.com VarseoWax CAD/Cast GEBRAUCHSANWEISUNG INSTRUCTIONS FOR USE MODE D EMPLOI INSTRUCCIONES DE USO ISTRUZIONI PER L USO Partners in Progress EN INSTRUCTION FOR USE VarseoWax CAD/Cast VarseoWax
More informationCharging base guide. A Sonova brand
Charging base guide A Sonova brand Thank you Thank you for choosing this rechargeable solution. We care deeply about people with hearing loss. We work closely with hearing healthcare professionals to make
More informationMass Dosing System. D a t a S c i e n c e s I n t e r n a t i o n a l TH STREET NW SUITE 100 ST. PAUL, MN USA (651) (800)
Mass Dosing System D a t a S c i e n c e s I n t e r n a t i o n a l 119 14TH STREET NW SUITE 100 ST. PAUL, MN 55112 USA OVERVIEW This manual highlights how DSI s Mass Dosing Controller interacts with
More informationAppendix M: Device Technique
Nursing Care of Dyspnea: The 6th Vital Sign in Individuals with Chronic Obstructive Pulmonary Disease (COPD) Appendix M: Device Technique Medications: Inhalation Devices Medications come in many forms.
More informationUSER S MANUAL QUESTIONS? CAUTION. Visit our website at.
Model No. NTCCBE950 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal (under seat) QUESTIONS? As a manufacturer, we are committed to providing
More information