1 International Letters of Chemistry, Physics and Astronomy Submitted: ISSN: , Vol. 68, pp Revised: doi: / Accepted: SciPress Ltd., Switzerland Online: Comparison of 3DCRT Dose Distribution in Radiotherapy for Lung Cancer Patient by Using AAA and PBC Algorithms Muhammad Masud Rana 1,3,a*, S. M. Azharul Islam 1,b, M. Moinul Islam 2,c, Md. Shakilur Rahman 2,d, Sarwar Alam 3,e, M. A. Bari 3,f 1 Department of Physics, Jahangirnagar University (JU), Savar, Dhaka, Bangladesh 2 Health Physics & Radioactive Waste Management Unit, INST, Bangladesh Atomic Energy Commission, Ganakbari, Savar, Dhaka, Bangladesh 3 Department of Oncology, Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh a* masudphysicist_bsmmu@yahoo.com, b azharphy@yahoo.com, c moinul19@baec.gov.bd, d shakilknu.kor@gmail.com, e drsarwarbd@yahoo.com,fpds.bsmmu@gmail.com *Corresponding author Keywords: Anisotropic Analytical Algorithm, Pencil Beam Convolution Algorithm, Treatment Planning System, Three Dimensional Conformal Radiation Therapy (3DCRT), Lung Cancer. Abstract. The Pencil Beam Convolution (PBC) algorithm in radiation treatment planning system is widely used to calculate the radiation dose distribution in radiotherapy planning. A new photon dose calculation algorithm known as Anisotropic Analytical Algorithm (AAA) by Varian Medical Systems is applied to investigate the difference of dose distribution by using AAA and PBC algorithms for the lung cancer with an inhomogeneity of its low density. In the present work, radiotherapy treatment planning of 10 lung cancer patients are designed with 6 MV photon beam using three-dimensional conformal radiation therapy (3DCRT) and dose distribution was calculated by the AAA and the PBC Algorithms. The dose distribution performance is evaluated by dose profile curve along transversal slice of PTV and Dose Volume Histogram (DVH) covered by the 95% isodose of PTV. The mean dose of organ at risks did not changed significantly but the volume of the PTV covered by the 95% isodose curve was decreased by 6% with inhomogeneity due to the algorithms. The dose distribution and the accuracy in calculating the absorbed dose of the AAA algorithm of the Varian Eclipse treatment planning system is analyzed and discussed. Introduction In radiotherapy, maximum control of tumors with minimum of complications to the normal tissues depends on various factors especially on the accuracy of absorbed dose deliver [1] to the tumor. Since under-dosage may not kill all the cancer cells and over-dosage can harm the surrounding healthy tissue more than necessary, which could lead to unwanted side effects [2]. In clinical data consideration lead to generally agreed recommendations on the required accuracy in clinical dosimetry for radical curative being given in ICRU report-24 (1976) for at least accuracy of ±5 % in the delivery of absorbed dose to the target volume of the treatment tumor [3-4]. Brahme [5] also proposed a tolerance value of accuracy in dose delivery of ±3.5 % at one standard deviation level. In radiobiology, the dose response relationship for tumor cell killing follow the sigmoidal curves at high dose which implies that the tumor control can only achieve with a very high precisional dose delivery. In recent years, the increased sophistication of treatment techniques and delivery methods, the accuracy of highly conformal radiotherapy has improved rapidly with technological advances. This leads the demands on modern treatment techniques require better modeling of treatment beams and more sophisticated modeling in the presence of in homogeneities in order to assure the accuracy in the calculation of dose distribution. In order to achieve such accuracy, the uncertainties in all stages of the radiotherapy process, such as dosimetry, simulation and planning to the treatment delivery, must be reduced as far as possible. The introduction of increasingly complex treatment techniques SciPress applies the CC-BY 4.0 license to works we publish:
2 International Letters of Chemistry, Physics and Astronomy Vol and the possibility for delivering higher doses in radiotherapy treatments has reinforced the requirement for accuracy in dose calculation algorithms. Historically, one of the most serious weaknesses in treatment planning systems has been their ability to accurately predict doses in the presence of inhomogeneities, particularly through poor consideration of electron transport [6]. Radiotherapy treatment planning is generally performed on dedicated computers using specialized treatment planning software. Dose calculation algorithms are the most critical software component in a computerized Treatment Planning System (TPS). Different algorithms are applied in different commercial treatment planning systems e.g., Elekta XiO: Clarkson, FFT Convolution, Multigrid Convolution, Superposition, Fast Superposition; for Phillips Pinnacle: Collapsed Cone Convolution, Pencil Beam and for Varian Eclipse: Anisotropic Analytical Algorithm, Pencil Beam Algorithm etc. The PBC algorithm is most common that implemented in the TPS Eclipse version (Varian Medical Systems), uses experimental measurements as part of the beam configuration [7]. The study for the accuracy of recent developed AAA algorithm is compared with Eclipse s Pencil Beam Convolution (PBC) algorithm by many authors [8-11] compared Monte Carlo (MC) simulation which was considered as gold standard in dose calculation. E. Sterpin et al. [12] have studied the accuracy of AAA algorithm against MC and compared with IMRT plans in presence of inhomogeneous tissue. Bragg et al. [6] compared AAA to the PBC algorithm and was not found any significant values of quality compared to IMRT treatments plans for prostate, parotid or nasopharynx while in case accurate modeling of lateral electron transport demonstrates there found a significant increases in the volume of PTV being under dosed in IMRT non-small cell lung cancer (NSCLC) treatments plans reported. The most recent studies of AAA and PBC algorithm was studied by Antonella Bufacchi et al. [9] for prostate and lung cancer planning in combination with NTCP (Normal Tissue Complication Probability) parameters that varied by 12.8% and 4.5% respectively between the algorithms. The large variation implies that a more detail studies of AAA algorithm in case of inhomogeneous tissues is highly required. The aim of this study was to evaluate differences in dose distributions in therapy treatment plans of lung tumors calculated with pencil beam convolution (PBC) algorithm and anisotropic analytical algorithm (AAA) of the Varian Eclipse treatment planning system. Beam profile and dose volume histogram (DVH) were used to get the performance of dose distribution using both AAA and PBC algorithms. This research work is performed with newly installed linear Accelerator (Clinac DHX, SN: 5550, Varian Medical Systems) of National Institute of Cancer Research and Hospital (NICRH), Dhaka, Bangladesh having a TPS (Varian Eclipse, platform: 10.0) provision for using AAA (version: ) and PBC (version: ) calculation algorithms. Materials and Methods The AAA is a three-dimensional (3D) pencil beam convolution/superposition algorithm that uses Monte Carlo derived kernels. Since the majority of the convolution operators appearing in the mathematical formalism can be converted into analytical expressions (which significantly reduce the computational time) the analytical property was added to the algorithm name. The AAA was originally conceived by Ulmer et al. (Ulmer and Harder 1995, 1996) [13-14] and Kaissl et al. (Ulmer and Kaissl 2003) [15]. The AAA accounts for tissue heterogeneity anisotropically in the entire three-dimensional neighborhood of an interaction site using photon scatter kernels in multiple lateral directions. The final dose distribution is obtained by the superposition of photon and electron convolutions. The pencil beam kernel (K) represents the absorbed dose distribution in the water phantom at standard SPD, resulting from a very small circular photon beam (2.5 mm diameter) and convolution. Convolution is done by summing a number of pencil beams, each weighted with the field intensity to obtain the total dose contribution. The PBC model generates the dose distribution matrix by convolution of pencil-beam kernels with a non-uniform field function; the pencil-beam kernels are derived from open-beam measurements. 10 lung cancer patients were performed with three dimensional conformal radiation therapy (3DCRT) on the AAA and PBC algorithms clinically. To compare the dose distribution according to the algorithms, we used the Anisotropic Analytical
3 56 Volume 68 Algorithm (version ) and the Pencil Beam Convolution (version ) by Eclipse treatment planning system (Platform: 10) in Varian Medical Systems. The images of thorax region all of the lung cancer patients taken by Brilliance Big Bore CT Simulator (Philips) and all the images were imported into Eclipse TPS of LINAC (Clinac DHX, SN: 5550, Varian Medical Systems) system. The 3D patient body was made using the imported images. Gross Tumour Volume (GTV), Clinical Target Volume (CTV), Planning Target Volume (PTV) and all Organ AT Risks (OAR) e.g. heart, lung etc. were contoured by hospital oncologist in all axial images according to standard contouring protocol (Fig: 1). All treatment plans were completed by using three dimensional conformal radiation therapy technique (3DCRT). (a) Fig. 1. (a) shows imported CT image for TPS planning. Figure (b) shows contoured structures, GTV- pink, PTV- red, Heart blue and Spinal cord Cyan A linear accelerator (Clinac DHX, SN: 5550, Varian Medical Systems) was assigned to all of the plans and five fields with different angles were used for the treatment plans with a Source to Axis Distance (SAD) of 100 cm (such as Fig: 2) with a 6 MV photon energy. Multi Leaf Collimator (MLC) were also used to made costume irregular treatment field. To get a homogeneous dose distribution different angle Enhancement Dynamic Wedges (EDW) were used in all of plan. The prescribed dose was set to 6000 cgy to the planning target volume at 200 cgy per fraction for each plan. (b) Fig. 2. Shows 3DCRT planning with 5 fields (14 14 cm 2, cm 2, cm 2, cm 2 and cm 2 ) isocentric technique All of the treatment plans were calculated by using AAA algorithm with 2.5 mm grid size. The treatment plans were copied and recalculated again by using PBC algorithm having same grid size.beam profile was taken by scanning along transvers direction through central axis from right to left with additional 50% distance of the respective tumor width both for AAA and PBC by using Eclipse Beam Profile tool (Fig: 3). Same procedure was applied to all the plans. All data convert to text file for comparison.
4 International Letters of Chemistry, Physics and Astronomy Vol Fig. 3. Figure shows profile and point dose for a 3DCRT isocentric technique lung cancer patient treated with 5 fields for AAA. By taking 95% isodose curve of the Planning Target Volume (PTV) and using Dose Volume Histogram (DVH) the performance of the dose distribution to the PTV and the organs at risk both for AAA and PBC algorithms were evaluated. Same procedure was applied to all the plans. Results and Discussion The treatment plan calculated with the AAA (105.1%) for the lung cancer patient has a lower absolute dose maximum in this transversal slice with about 10% compared to the PBC (115%) but approximately at the same location shown in Fig 4(a) and 4(b) because the AAA takes into account the lower amount of scattered radiation from the low density lung which the PBC doesn t. (a) AAA (b) PBC Fig. 4. Isodoses for the lung cancer patient calculated with the AAA and PBC through a transversal slice at dose absolute maximum. PTV is drawn in the image and 3DCRT treatment using 5 fields. From the 95% isodose curves, the dose difference from the two algorithms was significantly larger in the inhomogeneous lung such as the low electron density. From (Fig 5) the profiles through the tumour in the lung the PBC algorithm overestimate the absorbed dose compare to the AAA algorithm. Since the PBC overestimates the amount of scattered radiation from the low-density lung tissue therefore, the absorbed dose calculated by PBC algorithm is higher.
5 58 Volume 68 Fig. 5. Isodoses for the lung cancer patient calculated with the AAA and PBC through a transversal slice at dose absolute maximum. PTV is drawn in the image and 3DCRT treatment using 5 fields. In addition, from the Table 1, it is seen that in the profiles, lung tomour dose maximum (D max ) by using the AAA algorithm is approximately average 10.3% lower than the PBC algorithm. Table 1 Absolute dose maximum both for calculated AAA & PBC of lung cancer patients. Case no AAA(D max ) PBC(D max ) PBC(D max ) - AAA(D max ) (%) (%) (%) Average % 114.6% 10.3% The DVH shows that dose calculation by using AAA algorithm gives a lower absorbed dose to the PTV compare to the PBC (Fig 6).
6 International Letters of Chemistry, Physics and Astronomy Vol PTV AAA Heart AAA, PBC PTV PBC Spinal cord AAA, PBC Fig. 6. DVH for a lung cancer patient treated with (14 14 cm 2, cm 2, cm 2, cm 2 and cm 2 ) fields showing the dose distribution for PTV both for the AAA and the PBC. The organs at risk did not changed significantly but the volume of the PTV covered by the 95% isodose curve was decreased by average 6.09% due to performance AAA of algorithm. That means, the mean dose calculated by using AAA algorithm was average cgy. Whilst the mean dose calculated by the PBC algorithm was average cgy given in Table 2. Table 2 The AAA and PBC calculated mean dose (cgy) of the PTV from DVH covered by the 95% isodose. Case no AAA(PTV min ) PBC(PTV min ) PBC(PTV min ) - AAA(PTV min ) (%) decreased by AAA Average Conclusion In this study, we have tried to investigate possible clinical data for dose distribution and absorbed dose in 3DCRT treatment planning for lung cancer by using PBC and AAA algorithm. The differences between the two algorithm shows a significant value of dose variation in inhomogeneity case which implies more investigation requires to conduct the verification of AAA and PBC to compare both in experimentally and MC simulation method. It could be concluded here that the dose distribution and the accuracy in calculating the absorbed dose of the AAA algorithm is better than the PBC algorithm.
7 60 Volume 68 References [1] M.S. Rahman, G.N. Kim et al., TLD postal dose quality audit intercomparison for megavolts photon beam of radiotherapy centers in Bangladesh, Jour. Nucl. Sci. Tech. Sup 5 (2008) [2] B.J. Mijnheer, J.J. Battermann and A. Wambersie, What degree of accuracy is required and can be achieved in photon and neutron therapy?, Radio. Oncol. 8 (1987) [3] ICRU, Determination of absorbed dose in patient irradiated by means of X- or gamma rays in radiotherapy procedures, Report-24, Bethesda, MD: ICRU (1976). [4] A. Brahme, J. Chavaudra, T. Landberg et al., Accuracy requirements and quality assurance of external beam therapy with photon and electron, Acta. Oncol. Sup. 1 (1988) [5] A. Brahme, Dosimetric precision requirements in radiation therapy, Acta. Radiol. Oncol. 23 (1984) [6] C.M. Bragg, J. Conway, Dosimetric verification of the Anisotropic Analytical Algorithm for radiotherapy treatment planning, Radio. Oncol. 81 (2006) [7] P.M.R Storchi, L.J. Battum, E. Woudstra, Calculation of a pencil beam kernel from measured photon beam data, Phys. Med. Biol. 44 (1999) [8] V. Panettieri, P. Barsoum, M. Westermark, AAA and PBC calculation accuracy in the surface build-up region tangential beam treatments. Phantoms and breast case study with the Monte Carlo code PENELOPE, Radiat. Oncol. 93 (2009) [9] A. Bufacchi, B. Nardiello, R. Capparella, Clincal implications in the use of the PBC algorithm versus the AAA by comparison of different NTCP models/parameters, Radiat. Oncol (2013) [10] TDLF. Herman, K. Hibbitts, T. Herman, Evaluation of pencil beam convolution and anisotropic analytical algorithms in stereotactic lung irradiation, J. Medi. Phys. 36(4) (2011) [11] P. Carrasco, N. Jornet, M. A.Duch et al. Comparison of dose calculation algorithms in phantom with lung equivalent heterogeneities under conditions of lateral disequilibrium, Med. Phys. 31 (2004) [12] E. Sterpin E, M. Tomasej, B. D. Smedt et al., Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta Sl25 Linear Accelerator, Med Phys 34 (2007) [13] W. Ulmer, D. Harder, A Triple Gaussian Pencil beam Model for Photon beam Treatment Planning, Z. Med. Phys. 5 (1995) [14] W. Ulmer, D. Harder, Applications of a triple Gaussian pencil beam model for photon beam treatment planning, Z. Med. Phys. 6 (1996) [15] W. Ulmer, W. Kaissl, The inverse problem of a Gaussian convolution and its application to the finite size of the measurement, Phys. Med. Biol. 48 (2003)
Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom
Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom David Followill, Ph.D. Associate Director Radiological Physics Center RPC History Lesson
More informationQuality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose
Petrovic B Comparison of dose calculation algorithms for stereotaxy Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in and RT Dose Borislava Petrovic 1, Aleksandra Grządziel
More informationThe Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom
The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom Gary Fisher, B.S. David Followill, Ph.D. Geoffrey Ibbott, Ph.D. This investigation
More informationLeila E. A. Nichol Royal Surrey County Hospital
2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry
More informationFeasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment
Chinese Journal of Cancer Original Article Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment Suresh Rana 1 and ChihYao Cheng 2 Abstract The volumetric modulated
More informationAddress for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,
ORIGINAL ARTICLE Dosimetric Comparison of Different 3DCRT Techniques in Left Breast Cancer Radiotherapy Planning Abdus Sattar Mollah 1 and Meher Niger Sharmin 2 1 Department of Medical Physics, KhwajaYunus
More informationEfficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO
Investigations and research Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO M. Kunze-Busch P. van Kollenburg Department of Radiation Oncology, Radboud University Nijmegen Medical
More informationA comparative dosimetric analysis of the effect of heterogeneity corrections used in three treatment planning algorithms
The University of Toledo The University of Toledo Digital Repository Theses and Dissertations 2010 A comparative dosimetric analysis of the effect of heterogeneity corrections used in three treatment planning
More informationA TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,
More informationVariable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10
Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10 Simon Goodall Radiation Oncology Physicist Genesis Care Western Australia Introduction
More informationA VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI
More informationDosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer Tan Chek Wee 15 06 2016 National University Cancer Institute, Singapore Clinical Care Education Research
More informationThe bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes
The bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes Abdulhamid Chaikh1,2, Jean-Pierre Bresciani3,4, Jacques Balosso2,4 1Department of Radiation Oncology and
More informationRadiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments
Radiation Damage Comparison between Intensity Modulated Radiotherapy () and Field-in-field (FIF) Technique In Breast Cancer Treatments Huisi Ai 1 and Hualin Zhang 2 1. Department of Radiation Oncology,
More informationQuality assurance and credentialing requirements for sites using inverse planned IMRT Techniques
TROG 08.03 RAVES Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques Introduction Commissioning and quality assurance of planning systems and treatment delivery
More informationA Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population
A Dosimetric Comparison of Whole-Lung Treatment Techniques in the Pediatric Population Corresponding Author: Christina L. Bosarge, B.S., R.T. (R) (T) Indiana University School of Medicine Department of
More informationChapters from Clinical Oncology
Chapters from Clinical Oncology Lecture notes University of Szeged Faculty of Medicine Department of Oncotherapy 2012. 1 RADIOTHERAPY Technical aspects Dr. Elemér Szil Introduction There are three possibilities
More informationCURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT
CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT Purpose The purpose of this curriculum outline is to provide a framework for multidisciplinary training for radiation oncologists, medical
More informationIndependent corroboration of monitor unit calculations performed by a 3D computerized planning system
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 1, NUMBER 4, FALL 2000 Independent corroboration of monitor unit calculations performed by a 3D computerized planning system Konrad W. Leszczynski* and
More informationSBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session
Stereotactic Body Radiation Therapy Quality Assurance Educational Session J Perks PhD, UC Davis Medical Center, Sacramento CA SBRT fundamentals Extra-cranial treatments Single or small number (2-5) of
More informationBorges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1
Borges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1 Medicalconsult SA, Lisboa, Portugal; 2 Escola Superior de Tecnologias da Saúde, Lisboa, Portugal; 3 InsEtuto Tecnológico e Nuclear, InsEtuto Superior
More informationThe Physics of Oesophageal Cancer Radiotherapy
The Physics of Oesophageal Cancer Radiotherapy Dr. Philip Wai Radiotherapy Physics Royal Marsden Hospital 1 Contents Brief clinical introduction Imaging and Target definition Dose prescription & patient
More informationEvaluation of Dosimetry Check software for IMRT patient-specific quality assurance
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 3, 2015 Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance Ganesh Narayanasamy, Travis Zalman, Chul S. Ha,
More informationSilvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida
American Association of Medical Dosimetrists 2015 Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida Most
More informationActivity report from JCOG physics group
2013.5.9 Global Harmonization Group meeting ICCR2013 @ Melbourne Activity report from JCOG physics group 1 Hokkaido University, Graduate School of Medicine, 2 National Cancer Center, Center for Cancer
More informationQuality assurance in external radiotherapy
Quality assurance in external radiotherapy dr. Marius Laurikaitis medical physicist Oncological Hospital of Kaunas Medical University Hospital Kaunas, 2010-10-14 Acceptance and Commissioning Acceptance
More informationMeasurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation Therapy (3D-CRT); A Comparative Study Erik
More informationEvaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas
1 Carol Boyd Comprehensive Case Study July 11, 2013 Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas Abstract: Introduction:
More informationA Dosimetric study of different MLC expansion aperture For the radiotherapy of pancreas cancer
IOSR Journal of Applied Physics (IOSR-JAP) e-issn: 2278-861.Volume 6, Issue Ver. II (May-Jun. 201), PP 2- A Dosimetric study of different MLC expansion aperture For the radiotherapy of pancreas cancer
More informationDose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83
Special report Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83 Rapid development in imaging techniques, including functional imaging,
More informationAdditional Questions for Review 2D & 3D
Additional Questions for Review 2D & 3D 1. For a 4-field box technique, which of the following will deliver the lowest dose to the femoral heads? a. 100 SSD, equal dmax dose to all fields b. 100 SSD, equal
More informationComparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy
Turkish Journal of Cancer Volume 37, No. 2, 2007 59 Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy MUHAMMAD BASIM
More informationEvaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases
Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook
More informationPotential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana
University of Groningen Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's
More information3D-CRT Breast Cancer Planning
3D-CRT Breast Cancer Planning Tips and Tricks Bednář, V. 3D-CRT Obsolete or not? There are more advanced techniques than 3D-CRT, but 3D-CRT has some advantages: Availability and price Forward planning
More informationThe RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff
The RPC s Evaluation of Advanced Technologies AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff 1 http://rpc.mdanderson.org Supported by: NCI grants CA10953 and CA81647, and an
More informationDefining Target Volumes and Organs at Risk: a common language
Defining Target Volumes and Organs at Risk: a common language Eduardo Rosenblatt Section Head Applied Radiation Biology and Radiotherapy (ARBR) Section Division of Human Health IAEA Objective: To introduce
More informationA Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer
A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer Tony Kin Ming Lam Radiation Planner Dr Patricia Lindsay, Radiation Physicist Dr John Kim, Radiation Oncologist Dr Kim Ann Ung,
More informationData Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff
Data Collected During Audits for Clinical Trials July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff RPC Programs Assure... Constancy of basic machine calibration (TLD/OSLD Audits) Validity of treatment
More informationAssessing the shift of radiobiological metrics in lung radiotherapy plans using 2D gamma index
Original Article Assessing the shift of radiobiological metrics in lung radiotherapy plans using 2D gamma index Abdulhamid Chaikh, Jacques Balosso,2 Department of Radiation Oncology and Medical Physics,
More informationDosimetric Comparison: Acuros XB vs AAA
Dosimetric Comparison: Acuros XB vs AAA Leo El Hage, Chris James, Jim Frantzis, Roger Li, Venkata Sheshadri Epworth Radiation Oncology Epworth HealthCare Excellence. Everywhere. Everyday Background Epworth
More informationVerification of performance of Acuros XB Algorithm (AXB) Implemented on Eclipse Planning System
Original Article Research in Oncology 2018; Vol. 14, No. 1: 34-38. DOI: 10.21608/resoncol.2018.3026.1047 Verification of performance of Acuros XB Algorithm (AXB) Implemented on Eclipse Planning System
More informationHampton University Proton Therapy Institute
Hampton University Proton Therapy Institute Brief introduction to proton therapy technology, its advances and Hampton University Proton Therapy Institute Vahagn Nazaryan, Ph.D. Executive Director, HUPTI
More informationLung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014
Lung Spine Phantom Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 The study groups are requesting that each institution keep the phantom for no more than 2 week. During this
More informationIROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015
IROC Liver Phantom Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 The study groups are requests that each institution keep the phantom for no more than 2 weeks. During
More informationHeterogeneity Corrections in Clinical Trials
Heterogeneity Corrections in Clinical Trials Niko Papanikolaou Departments of Radiology and Radiation Oncology U of TX Health Science Center, San Antonio, TX Eric Klein Department of Radiation Oncology
More informationSBRT Credentialing: Understanding the Process from Inquiry to Approval
SBRT Credentialing: Understanding the Process from Inquiry to Approval David Followill, Ph.D. (presented by Andrea Molineu, M.S.) IROC Houston QA Center July 15, 2015 What is credentialing? Verification
More informationOriginal Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem
Original Article Treatment Planning Evaluation of Sliding Window and Multiple Static Segments Technique in Intensity Modulated Radiotherapy for Different Beam Directions Teyyiba Kanwal, Muhammad Khalid,
More informationWHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY
doi:10.1016/j.ijrobp.2009.03.029 Int. J. Radiation Oncology Biol. Phys., Vol. 75, No. 1, pp. 253 259, 2009 Copyright Ó 2009 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/09/$ see front
More informationThe objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical
The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical sites. The final aim will be to be able to make out these
More informationI. Equipments for external beam radiotherapy
I. Equipments for external beam radiotherapy 5 linear accelerators (LINACs): Varian TrueBeam 6, 10 & 18 MV photons, 6-18 MeV electrons, image-guided (IGRT) and intensity modulated radiotherapy (IMRT),
More informationIMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia
IMRT - the physician s eye-view Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia The goals of cancer therapy Local control Survival Functional status Quality of life Causes
More informationNIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning
NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD Dosimetry Planning CPT Codes: 77295, 77300, 77301, 77306, 77307, 77321, 77316, 77317, 77318, 77331, 77399 Original Date: April, 2011 Last Reviewed
More informationVerification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film
Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film E.B.Rajmohan¹, Pratik Kumar¹, Bhudatt Paliwal,² David Westerly², N.Gopishankar³, R.K.Bisht³, D.Tewatia²,
More informationTo Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence
SCIENCE & TECHNOLOGY To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence Alburuj R. Rahman*, Jian Z. Wang, Dr. Z. Huang, Dr. J. Montebello Department of
More informationD DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology
Journal of Life Sciences 9 (2015) 120-126 doi: 10.17265/1934-7391/2015.03.005 D DAVID PUBLISHING Uncertainties of in vivo Dosimetry Using Semiconductors Zeina Al Kattar, Hanna El Balaa and Saeed Zahran
More informationA treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
Peters et al. Radiation Oncology 2014, 9:153 RESEARCH Open Access A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse Samuel Peters
More informationAccuracy Requirements and Uncertainty Considerations in Radiation Therapy
Departments of Oncology and Medical Biophysics Accuracy Requirements and Uncertainty Considerations in Radiation Therapy Introduction and Overview 6 August 2013 Jacob (Jake) Van Dyk Conformality 18 16
More informationIMAT: intensity-modulated arc therapy
: intensity-modulated arc therapy M. Iori S. Maria Nuova Hospital, Medical Physics Department Reggio Emilia, Italy 1 Topics of the talk Rotational IMRT techniques: modalities & dedicated inverse-planning
More informationTreatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize
More informationQuality assurance of volumetric modulated arc therapy using Elekta Synergy
Acta Oncologica, 2009; 48: 11931197 ORIGINAL ARTICLE Quality assurance of volumetric modulated arc therapy using Elekta Synergy AKIHIRO HAGA 1, KEIICHI NAKAGAWA 1, KENSHIRO SHIRAISHI 1, SAORI ITOH 1, ATSURO
More informationLevel of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013
Level of Accuracy Practically Achievable in Radiation Therapy David Followill and RPC staff August 6, 2013 Sources of Treatment Uncertainty Machine functioning Radiation dose determination Patient specific
More informationOut-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients
EURAMED,MELODI and EURADOS Workshop, Helsinki 19.-20.4.2017 Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients Jan Seppälä, Chief Physicist Tuomas Virén, Medical
More informationInstitute of Oncology & Radiobiology. Havana, Cuba. INOR
Institute of Oncology & Radiobiology. Havana, Cuba. INOR 1 Transition from 2-D 2 D to 3-D 3 D conformal radiotherapy in high grade gliomas: : our experience in Cuba Chon. I, MD - Chi. D, MD - Alert.J,
More informationRadiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability
Original Article Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability Rana S, Cheng CY Department of Medical
More informationAdvanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*
Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark* Purpose: To evaluate an institution s 3D treatment planning process and the institution
More informationRADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident
Resident s Name: RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Rotation: PHYS 703: Clinical Rotation 2 Inclusive dates of rotation: Feb. 26, 2016 Aug. 25, 2016 Director or Associate
More informationAbdulhamid Chaikh 1,2, Jacques Balosso 1,2. Introduction
Original Article Statistical control process to compare and rank treatment plans in radiation oncology: impact of heterogeneity correction on treatment planning in lung cancer Abdulhamid Chaikh 1,2, Jacques
More informationIntensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain
1 Carol Boyd March Case Study March 11, 2013 Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain History of Present Illness:
More informationNormal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT
Received: 28 September 2017 Revised: 17 November 2017 Accepted: 28 December 2017 DOI: 10.1002/acm2.12276 RADIATION ONCOLOGY PHYSICS Normal tissue doses from MV image-guided radiation therapy (IGRT) using
More informationVOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER
Romanian Reports in Physics, Vol. 67, No. 3, P. 978 986, 2015 VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER D. ADAM 1, 2, M.D. SUDITU 1, 2, R. POPA 1, 2, V. CIOCALTEI
More informationREVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria
REVISITING ICRU VOLUME DEFINITIONS Eduardo Rosenblatt Vienna, Austria Objective: To introduce target volumes and organ at risk concepts as defined by ICRU. 3D-CRT is the standard There was a need for a
More informationDOSE DISTRIBUTION ANALYZE OF THE BODY STI USED MONTE CARLO METHOD
Proceedings of the Tenth EGS4 Users' Meeting in Japan, KEK Proceedings 2002-18, p.65-73 DOSE DISTRIBUTION ANALYZE OF THE BODY STI USED MONTE CARLO METHOD N. Tohyama, H. Saitoh, T. Fujisaki 1, S. Abe 1
More informationComparing Study between Conventional and Conformal Planning Radiotherapy
Middle East Journal of Applied Sciences Volume : 06 Issue :04 Oct.-Dec. 2016 Pages: 660-670 Comparing Study between Conventional and Conformal Planning Radiotherapy 1 Aida Salama, 1 Sahar Awad, 2 Tamer
More informationTransition to Heterogeneity Corrections. Why have accurate dose algorithms?
Transition to Heterogeneity Corrections Eric E. Klein, M.S., Washington University, St. Louis, MO Craig Stevens, M.D., Ph.D., MD Anderson Cancer Center, Houston, TX Nikos Papinikolou, Ph.D., University
More informationGuidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy
Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy VERSION 2.1 April 2015 Table of Contents Abbreviations & Glossary... 3 Executive Summary...
More informationReena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery
Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery Reena Phurailatpam Tejpal Gupta, Rakesh Jalali, Zubin Master, Bhooshan Zade,
More informationThe performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 14, NUMBER 6, 2013 The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media Monica W.K.
More information3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Iran. J. Radiat. Res., 2007; 5 (1): 1-8 3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis A.K. Bhardwaj 1*,T.S.
More informationThe Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction
1 The Effects of DIBH on Liver Dose during Right-Breast Treatments Megan E. Sullivan B.S.R.T.(T)., Patrick A. Melby, B.S. Ashley Hunzeker, M.S., CMD, Nishele Lenards, M.S., CMD Medical Dosimetry Program
More informationElectron Beam ET - Reloaded Therapy - Reloaded
8/4/216 Electron Beam ET - Reloaded Therapy - Reloaded Qiuwen Wu, Ph.D. Department of Radiation Oncology Duke University 1 Introduction: e vs. γ vs. p Electron Photon Proton Depth dose and lateral profiles
More informationEvaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer
1 Charles Poole April Case Study April 30, 2012 Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer Abstract: Introduction: This study
More informationMONTE CARLO BASED DOSIMETRY OF HEAD-AND-NECK PATIENTS TREATED WITH SIB-IMRT
doi:10.1016/j.ijrobp.2005.09.049 Int. J. Radiation Oncology Biol. Phys., Vol. 64, No. 3, pp. 968 977, 2006 Copyright 2006 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/06/$ see front
More informationInhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system
Journal of Physics: Conference Series PAPER OPEN ACCESS Inhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system To cite this article: S Yani et al 2016 J.
More informationPlanning Optimization of Conformal Radiotherapy Techniques for Meningioma Brain Tumors
Med. J. Cairo Univ., Vol. 80, No. 1, June: 213-221, 2012 www.medicaljournalofcairouniversity.com Planning Optimization of Conformal Radiotherapy Techniques for Meningioma Brain Tumors AIDA SALAMA, Ph.D.*;
More informationClinical Impact of Couch Top and Rails on IMRT and Arc Therapy
Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 8-2011 Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy
More informationFollow this and additional works at: Part of the Medicine and Health Sciences Commons
Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 8-2012 EVALUATION OF THE EFFECTIVENESS OF ANISOTROPIC ANALYTICAL ALGORITHM
More informationIMRT Planning Basics AAMD Student Webinar
IMRT Planning Basics AAMD Student Webinar March 12, 2014 Karen Chin Snyder, MS Senior Associate Physicist Department of Radiation Oncology Disclosures The presenter has received speaker honoraria from
More informationIROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015
IROC Lung Phantom 3D CRT / IMRT Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015 The IROC requests that each institution keep the phantom for no more than 2 weeks. During
More informationBaotian Huang 1, Lili Wu 1, Peixian Lin 2 and Chuangzhen Chen 1*
Huang et al. Radiation Oncology (2015) 10:53 DOI 10.1186/s13014-015-0357-0 RESEARCH Open Access Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy
More information4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest
SRS using the CyberKnife Sonja Dieterich, PhD, DABR Associate Professor University of California Davis Disclaimer/Conflict of Interest Consulting agreements with Broncus Medical and CyberHeart, Inc. Scientific
More informationDosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: Monte Carlo studies in patient geometries
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 1, WINTER 2002 Dosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: Monte Carlo studies in patient geometries
More informationEQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS
PAPER EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS Isra Israngkul Na Ayuthaya *, Sivalee Suriyapee, Phongpheath Pengvanich
More informationTopics covered 7/21/2014. Radiation Dosimetry for Proton Therapy
Radiation Dosimetry for Proton Therapy Narayan Sahoo Department of Radiation Physics University of Texas MD Anderson Cancer Center Proton Therapy Center Houston, USA Topics covered Detectors used for to
More informationClinical Implementation of SRS/SBRT
Clinical Implementation of SRS/SBRT Anil Sethi, PhD, FAAPM Loyola University Medical Center November 4, 2017 Disclosures Speaker: BrainLAB Standard Imaging Research collaboration: RaySearch 2 Learning
More informationDosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 4, 2015 Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy Kimiko
More informationComputerized Treatment Planning in Radiation Therapy of Intact Breast: Influence of Number of CT-Cuts
Journal of the Egyptian Nat. Cancer Inst., Vol. 17, No. 2, June: 76-84, 2005 Computerized Treatment Planning in Radiation Therapy of Intact Breast: Influence of Number of CT-Cuts TAREK SHOUMAN, M.D.; ZEINAB
More informationRPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy
RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy Guidelines for Planning and Irradiating the RPC Liver Phantom. Revised Dec 2005 Credentialing for this protocol requires four steps:
More informationPage 1. Helical (Spiral) Tomotherapy. UW Helical Tomotherapy Unit. Helical (Spiral) Tomotherapy. MVCT of an Anesthetized Dog with a Sinus Tumor
Helical (Spiral) Tomotherapy Novel Clinical Applications of IMRT Linac Ring Gantry CT Detector X-Ray Fan Beam Binary Multileaf Collimator Binary MLC Leaves James S Welsh, MS, MD Department of Human Oncology
More information