Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management
|
|
- Lee Patrick
- 5 years ago
- Views:
Transcription
1 Clinical Precision for Best Cancer Care Dee Mathieson Senior Vice President Oncology Business Line Management
2 Optimizing clinical results Key drivers in modern Radiation Therapy Clinical precision Continuous clinical innovation Close collaboration with clinical partners Cost containment and efficiency Comprehensive Services and Software solutions
3 Breast Prostate Lung Brain H&N Spine Other Radiation Treatment planning Radiation Information Systems Medical Oncology Information Systems Laboratory Information Systems Cancer Registry Surgical Planning Synergy Axesse LGK Perfexion MEG Oncology Research Neuroscience research Oncology Marketing, Neuroscience Marketing Pathology Marketing Linac sales, OIS sales, Pathology sales, Registry sales, GK/Perfexion sales, MEG sales RO customers MO customers, Neuro customers, Pathology customers, Registry customers
4 Cancer incidence in women Breast Colon & rectum Lund & bronchus CA Cancer J Clin 2006; 56: Uterine corpus 20 Ovary Non-hodgkin lymphoma Year of diagnosis
5 Breast clinical challenge Delicate underlying anatomy Lung Heart for left sided breast Patient breathing Target moves Accurate and repeatable set up Tissues very moveable Side effects Skin reddening and soreness Images courtesy of William Beaumont Hospital, Detroit
6 Current issues in Cancer Management Cancer death 100 Lung and bronchus 90 Rate of 100,000 population Stomach Colon and rectum Prostate 20 Pancreas 10 0 Leukemia Liver Year of death CA Cancer J Clin 2006; 56:
7 The challenge of Lung Cancer Respiratory Motion Lung tumors are moving targets and are subject to baseline shift
8 Integrity 6 th generation integrated digital control system Collimator position Leaf alignment Gantry position Gantry speed Monitor units
9 Continuously Variable Dose Rate From Discrete dose rate delivery To Continuous dose rate delivery Finer dose rate control Faster delivery times More accurate treatments
10 Customer experience of Integrity VMAT plans are significantly accelerated and the treatment delivery is a lot smoother than with the current control system. On average, it has reduced treatment times by 20-30% Prof. Frank Lohr, Vice Chairman of the Department of Radiation Oncology University Medical Center Mannheim, Germany
11 High dose rate Flattened beams Unflattened beams Data courtesy of research from Birmingham Hospital More homogenous distribution Hotspots moved from beam edge Faster treatment
12 3 tiers of safety Accurate & safe MOSAIQ/R& V Guardian Integrity Results Tier 1 in Tier 2 Tier 3 - Checks parameters of prescription - Ensures correct set-up Enhanced patient safety Continuously Smoother verifies patient parameters flow & checks correct position during delivery Improved patient throughput Confidence - Supervises with and all check delivery all techniques systems - Automatic safety stop
13 Agility Intelligent Conformance from a next generation beam-shaping solution This feature is in research and is not for sale or distribution.
14 Seamless field delivery 160 x 5mm Leaves across 40cm x 40cm field Capable of Interdigitation & Island Shapes Maximum effective leaf speed up to 6.5 cm/s 1mm dynamic tolerance No need to split the field More flexible planning Faster delivery Dynamic delivery Faster treatment planning This feature is in research and is not for sale or distribution.
15 Intelligent leaf positioning and design Low transmission < 0.5% for 6MV Small penumbra Sculpted dynamic diaphragms Dynamically assists with OAR protection, beam shaping & dose modulation Flexible shapes Reduced integral dose Protects organs at risk Improved plan quality Easy upgrade This feature is in research and is not for sale or distribution.
16 Rubicon Optical Technology Direct readout of leaf positions Fluorescing Ruby locators Distinct wavelengths Independent field light Reduced QA time Accurate Reliable Reproducible Inherent safety
17 ASTRO 2009 Combined leaf guide and leaf speed is 65mm/s Measurements obtained under the most unfavorable conditions St James's Institute of Oncology, Leeds Teaching Hospitals NHS Trust, UK
18 ESTRO 2010 To establish the accuracy of Monte Carlo calculations compared with measured characteristics Concludes that minimal changes would be expected to be made in dosimetric models of the new head in radiotherapy treatment planning systems. St James's Institute of Oncology, Leeds Teaching Hospitals NHS Trust, UK
19 Monaco New paradigm in treatment planning Biological Modeling Constrained Optimization Single and Multi Arc VMAT Sensitivity Analysis Monte Carlo Dose Algorithm Multicriterial Goals Voxel-based Structure Control Smart Sequencing
20 Biological modelling Takes into account the underlying biological effects of radiation on cells Optimizes based on the nature of the structure Parallel [Lung] Serial [Spinal Cord]
21 Smart Sequencing Fluence smoothing Weight optimization Minimum MU/segment Minimum segment area (cm 2 ) Shape optimization
22 MOSAIQ Diagnostic Imaging Image Fusion (CT, MRI, PET, US,...) Segmentation and contouring Deformable registration Powered by MOSAIQ Dose Accumulation MOSAIQ EMR Optimization Dose calculation and display Treatment Imaging Trial plan comparison, selection, review and approval
23 Progressive innovations in Image Guidance Ease of use Single button Push CBCT Advanced 3D image registration tools Simultaneous image reconstruction Low dose Accuracy Electronic alignment of image to radiation isocenter for sub-mm resolution Large field of view 4D imaging Symmetry
24 Odense University Hospital, Denmark Increased confidence treating lung tumors All lung patients now imaged with Symmetry Access to advanced 4D imaging, both at the CT scanner and on Elekta Synergy, has enabled new clinical protocols with individualized treatment margins. This has allowed margins to be reduced and the surrounding tissue protected Carsten Brink, Head of Research and Development
25 Cancer incidence in men Rate per 100,000 population Prostate Lung & bronchus 80 Colon & rectum 60 Urinary bladder 40 Non-hodgkin lymphoma 20 Melanoma of the skin Year of diagnosis CA Cancer J Clin 2006; 56:
26 MLC Tracking research Research is on existing MLC Agility high speed dynamic leaf guide and leaves optimized for tracking This feature is in research and is not for sale or distribution. Data courtesy Royal Marsden, London, UK
27 Couch Tracking research This feature is in research and is not for sale or distribution. Data courtesy Coventry, UK
28 Breast Prostate Lung Brain H&N Spine Other Radiation Treatment planning Radiation Information Systems Medical Oncology Information Systems Laboratory Information Systems Cancer Registry Surgical Planning Synergy Axesse LGK Perfexion MEG Oncology Research Neuroscience research Oncology Marketing, Neuroscience Marketing Pathology Marketing Linac sales, OIS sales, Pathology sales, Registry sales, GK/Perfexion sales, MEG sales RO customers MO customers, Neuro customers, Pathology customers, Registry customers
Elekta - a partner and world-leading supplier
Experience Elekta Elekta - a partner and world-leading supplier of clinical solutions for image guided radiation therapy, stereotactic radiotherapy, radiosurgery and brachytherapy, as well as advanced
More informationElekta R&D Update 22 January 2015, Utrecht
1 Elekta R&D Update 22 January 2015, Utrecht Elekta R&D Update - 22 January 2015, Utrecht 11.00 R&D Update Niklas Savander President and CEO 11.15 Atlantic Positioning Dee Mathieson, SVP Oncology Business
More informationElekta Synergy Digital accelerator for advanced IGRT
Elekta Synergy Digital accelerator for advanced IGRT Setting the standard for confident care The Field of Radiation Therapy is Constantly Changing Being able to take full advantage of the latest clinical
More informationEvaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases
Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook
More informationElekta Innovation and Growth. ESTRO 2012 Capital Markets Presentation
Elekta Innovation and Growth ESTRO 2012 Capital Markets Presentation 15.00 Introduction Partner in cancer care Growth Tomas Puusepp President and CEO 15.30 Patient-focused development Cancer care solutions
More informationVariable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10
Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10 Simon Goodall Radiation Oncology Physicist Genesis Care Western Australia Introduction
More informationElekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control
Elekta Infinity Digital accelerator for advanced treatments Redefining treatment precision, speed and control Do you have the confidence to increase conformance and speed without compromising target coverage?
More informationA TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,
More informationElekta Infinity Digital accelerator for advanced treatments
Elekta Infinity Digital accelerator for advanced treatments Redefining treatment precision, speed and control Confidence to increase conformance and speed without compromising target coverage Set yourself
More informationS Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M
s y n c h r o n y r e s p i r a t o r y t r a c k i n g s y s t e m S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M The Synchrony System tracks respiration in real time and automatically
More informationAdvances in external beam radiotherapy
International Conference on Modern Radiotherapy: Advances and Challenges in Radiation Protection of Patients Advances in external beam radiotherapy New techniques, new benefits and new risks Michael Brada
More informationTechnology Challenges of Commercial Medical Electron Accelerators
Technology Challenges of Commercial Medical Electron Accelerators John Allen Chief Engineer Elekta Ltd Aims of this talk Medical Radiotherapy is already a large and profitable business Well established
More informationSBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session
Stereotactic Body Radiation Therapy Quality Assurance Educational Session J Perks PhD, UC Davis Medical Center, Sacramento CA SBRT fundamentals Extra-cranial treatments Single or small number (2-5) of
More informationImplementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy
Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy Implementation of radiosurgery and SBRT requires a fundamentally sound approach Errors don t blur out
More informationXSIGHT LUNG TRACKING SYSTEM
XSIGHT LUNG TRACKING SYSTEM CYBERKNIFE SYSTEM HIGHLIGHTS Continual image guidance Without the need for staff intervention or treatment interruption, the CyberKnife s revolutionary image guidance technology
More informationA model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms
1 st Workshop: Radiotherapy Modelling - Luz Saint Sauveur, Sep 2016 A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms A R Barbeiro 1, A Ureba 2, J A Baeza 3,
More informationImportant information
Important information This presentation includes forward-looking statements including, but not limited to, statements relating to operational and financial performance, market conditions, and other similar
More informationA treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
Peters et al. Radiation Oncology 2014, 9:153 RESEARCH Open Access A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse Samuel Peters
More informationPrecisely Maximize Dose, side effects, Patient
Precisely Maximize Dose, Minimize side effects, Maximize Patient Comfort Key Differentiators: The CyberKnife M6 Series Industry-leading precision and patient comfort Enables full-body robotic radiosurgery,
More information8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation
Online MR-IG-ART Dosimetry and Dose Accumulation Deshan Yang, PhD, Associate Professor Department of Radiation Oncology, School of Medicine Washington University in Saint Louis 1 Disclosure Received research
More informationRadiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague
Radiosurgery by Leksell gamma knife Josef Novotny, Na Homolce Hospital, Prague Radiosurgery - Definition Professor Lars Leksell The tools used by the surgeon must be adapted to the task and where the human
More informationVarian Treatment. Streamlined Treatment Delivery Management Application. Specifications
Varian Treatment Streamlined Treatment Delivery Management Application Specifications Specifications Varian Treatment 1 Introduction Streamlined Treatment Delivery Management Varian Treatment verifies
More informationEfficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO
Investigations and research Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO M. Kunze-Busch P. van Kollenburg Department of Radiation Oncology, Radboud University Nijmegen Medical
More informationProtura Robotic Patient Positioning System. for efficiency + performance
Protura Robotic Patient Positioning System for efficiency + performance Protura Robotic Patient Positioning System The Protura Robotic Patient Positioning System is the ultimate in robotic patient motion
More informationStereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS
Stereotactic Radiosurgery Extracranial Stereotactic Radiosurgery Annette Quinn, MSN, RN Program Manager, University of Pittsburgh Medical Center Using stereotactic techniques, give a lethal dose of ionizing
More informationFrom position verification and correction to adaptive RT Adaptive RT and dose accumulation
From position verification and correction to adaptive RT Adaptive RT and dose accumulation Hans de Boer Move away from Single pre-treatment scan Single treatment plan Treatment corrections by couch shifts
More informationQUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT
QUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT G. Guidi Az. Ospedaliero-Universitaria di Modena - Policlinico, Modena Guidi.Gabriele@policlinico.mo.it Phone: +39 059 422 5699 AGENDA Overview of the
More informationCyberknife Stereotactic Treatment
Cyberknife Stereotactic Treatment Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA DISCLAIMER: I am not affiliated with any vendor and did not receive any financial support from any vendor.
More informationPRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT
PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT BENEFITS OF THE CYBERKNIFE TREATMENT DELIVERY SYSTEM True robotic precision: Enable high definition radiotherapy anywhere in the body with the
More informationtypical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the
Precisely maximize dose, Versatile, efficient and effective for the BENEFITS OFandTHE CYBERKNIFE TREATMENT minimize side effects range of radiation oncology patients maximize patient comfort DELIVERY SYSTEM
More informationIngenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning
Ingenia MR-RT MR Systems The comprehensive MR-sim solution to fit your planning Table of contents Experience the difference MRI makes 3 A comprehensive MR-sim solution 4 Position with precision 6 Tailored
More informationHelical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System
The Challenges Associated with Differential Dose Delivery using IMRT Chester Ramsey, Ph.D. Director of Medical Physics Thompson Cancer Center Knoxville, Tennessee, U.S.A Collaborators Chester Ramsey, Ph.D.
More informationTreatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize
More informationDosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer Tan Chek Wee 15 06 2016 National University Cancer Institute, Singapore Clinical Care Education Research
More informationIn-Room Radiographic Imaging for Localization
In-Room Radiographic Imaging for Localization Fang-Fang Yin, Zhiheng Wang, Sua Yoo, Devon Godfrey, Q.-R. Jackie Wu Department of Radiation Oncology Duke University Medical Center Durham, North Carolina
More informationMotion gating and tracking techniques: overview and recent developments
Motion gating and tracking techniques: overview and recent developments Gig S Mageras, PhD, FAAPM Department of Medical Physics Memorial Sloan Kettering Cancer Center, New York MSK/gsm 15-Jun-2018 1 Disclosure
More informationQuality assurance of volumetric modulated arc therapy using Elekta Synergy
Acta Oncologica, 2009; 48: 11931197 ORIGINAL ARTICLE Quality assurance of volumetric modulated arc therapy using Elekta Synergy AKIHIRO HAGA 1, KEIICHI NAKAGAWA 1, KENSHIRO SHIRAISHI 1, SAORI ITOH 1, ATSURO
More informationLeila E. A. Nichol Royal Surrey County Hospital
2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry
More informationDosisverifikation mit Delta 4 Discover während der Behandlung
Dosisverifikation mit Delta 4 Discover während der Behandlung Anders Adolfson, Regional Sales Manager at Scandidos AK IMRT 2015 in Erlangen, March 19 th 2015 Agenda Which problem does Delta 4 Discover
More informationTechnique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases
Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases Kimberly Dempsey, BS, CMD, RT(T) Heather Smith, MS, CMD, RT(R)(T) The University of Alabama
More informationLinac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR
Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR PhD, FAAPM, FACR, FASTRO Department of Radiation Oncology Indiana University School of Medicine Indianapolis, IN, USA Indra J. Das,
More informationDisclosures. Overview 8/3/2016. SRS: Cranial and Spine
SRS: Cranial and Spine Brian Winey, Ph.D. Department of Radiation Oncology Massachusetts General Hospital Harvard Medical School Disclosures Travel and research funds from Elekta Travel funds from IBA
More informationMany vendors are beginning to allow couch motion during radiation delivery.
Dynamic Couch Motion Many vendors are beginning to allow couch motion during radiation delivery. Varian developer mode allows institutions to perform research using these types of treatments. Tomotherapy
More informationMedical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center
Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center All students accepted into the Medical Dosimetry Graduate Certificate Program
More informationAsynchronization. (aka MLC interplay effect with tumor motion)
Asynchronization (aka MLC interplay effect with tumor motion) Asynchronization is what happens when two moving parts do not align as planned. Like when my mother wants a photograph of her five young grandchildren.
More informationFROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017
FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE Geoffrey S. Ibbott, Ph.D. June 20, 2017 1 DISCLOSURES My institution holds Strategic Partnership Research Agreements with Varian, Elekta, and Philips
More information02 CyberKnife: Treatment Delivery
TREATMENT DELIVERY CyberKnife Treatment Delivery System The CyberKnife System is the first and only robotic radiosurgery system to offer highly precise and customizable, non-surgical treatment options
More informationChanging Paradigms in Radiotherapy
Changing Paradigms in Radiotherapy Marco van Vulpen, MD, PhD Mouldroomdag-2015 Towards the elimination of invasion 1 NIH opinion on the future of oncology Twenty-five years from now,i hope that we won
More informationRadiotherapy and Radiosurgery
RapidArc Radiotherapy and Radiosurgery RapidArc Faster. Sharper. Smarter. * It s true for the latest generation of RapidArc technology, and it can be true for your clinic. The oncology landscape has shifted
More informationPatient and Linac QA - present and the future
Patient and Linac QA - present and the future IBA Dosimetry Sandra Kos Service Department Customer Support Specialist sandra.kos@iba-group.com 1 IBA Dosimetry Part of IBA Group OUR MISSION At IBA we dare
More informationApplications of Modern Radiotherapy Systems
Applications of Modern Radiotherapy Systems Thomas Rockwell Mackie Professor University of Wisconsin Co-Founder and Chairman of the Board TomoTherapy Inc. Financial Disclosure I am a founder and Chairman
More informationSBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)
SBRT TREATMENT PLANNING: TIPS + TRICKS Rachel A. Hackett CMD, RT(T) OUTLINE Brief radiobiology review 3D CRT Tx Planning VMAT Tx Planning Protocols Other Sites Oligomets Spine Liver Kidney Adrenal Gland
More informationIntroduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology
Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology Philip Mayles Clatterbridge Centre for Oncology, Wirral, UK 1 What is RapidArc (or VMAT)?
More informationImage Guided Stereotactic Radiotherapy of the Lung
Image Guided Stereotactic Radiotherapy of the Lung Jamie Marie Harris, MS DABR Avera McKennan Radiation Oncology September 25, 2015 Stereotactic Body Radiotherapy - Clinical Dose/Fractionation - Normal
More informationDepartment of Radiation Oncology SMART. Stereotactic MR-guided adaptive radiotherapy. Marloes Jeulink Omar Bohoudi
SMART Stereotactic MR-guided adaptive radiotherapy Department of Radiation Oncology Marloes Jeulink Omar Bohoudi First clinical treatment May 4th 2016 First clinical treatment May 4 th 2016 MR-guided RT
More informationFuture Therapeutic Developments in Head and Neck Cancer
Future Therapeutic Developments in Head and Neck Cancer Professor Kevin Harrington Joint Head of Division of Radiotherapy and Imaging The Institute of Cancer Research/The Royal Marsden NIHR Biomedical
More informationTHE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS
THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS ICTP SCHOOL ON MEDICAL PHYSICS FOR RADIATION THERAPY DOSIMETRY AND TREATMENT PLANNING FOR BASIC AND ADVANCED APPLICATIONS March
More informationIMRT Planning Basics AAMD Student Webinar
IMRT Planning Basics AAMD Student Webinar March 12, 2014 Karen Chin Snyder, MS Senior Associate Physicist Department of Radiation Oncology Disclosures The presenter has received speaker honoraria from
More informationIndependent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA
Independent Dose Verification for IMRT Using Monte Carlo C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA Outline Why Monte Carlo for IMRT QA? Experimental verification
More informationEORTC Member Facility Questionnaire
Page 1 of 9 EORTC Member Facility Questionnaire I. Administrative Data Name of person submitting this questionnaire Email address Function Phone Institution Address City Post code Country EORTC No Enter
More informationOverview of Advanced Techniques in Radiation Therapy
Overview of Advanced Techniques in Radiation Therapy Jacob (Jake) Van Dyk Manager, Physics & Engineering, LRCP Professor, UWO University of Western Ontario Acknowledgements Glenn Bauman Jerry Battista
More informationHerlev radiation oncology team explains what MRI can bring
Publication for the Philips MRI Community Issue 46 2012/2 Herlev radiation oncology team explains what MRI can bring The radiotherapy unit at Herlev University Hospital investigates use of MRI for radiotherapy
More informationIMAT: intensity-modulated arc therapy
: intensity-modulated arc therapy M. Iori S. Maria Nuova Hospital, Medical Physics Department Reggio Emilia, Italy 1 Topics of the talk Rotational IMRT techniques: modalities & dedicated inverse-planning
More informationMRIdian. Linac Advantage. For distribution in the United States
MRIdian Linac Advantage For distribution in the United States MRI + LINAC THE FUTURE IS HERE SIMULTANEOUS IMAGING AND TREATMENT because organ motion matters Visibly Different It is a simple truth. Voluntary
More informationThe MRIdian Advantage
The MRIdian Advantage SIMULTANEOUS IMAGING AND TREATMENT because organ motion matters Visibly Different It is a simple truth. Involuntary life-sustaining movements don t stop while your patients are receiving
More informationA New Standard of Care. ASTRO 2017 Update (NASDAQ: VRAY) 1
A New Standard of Care ASTRO 2017 Update (NASDAQ: VRAY) 1 Disclaimer Forward-Looking Statements This presentation may contain forward-looking statements that are based on our current expectations of the
More informationRadiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions
Radiation Oncology The conf ident path to treatment Philips Radiation Oncology Solutions The confident path to treatment Philips Radiation Oncology Solutions Imaging Image registration Contouring Treatment
More informationIntensity Modulated RadioTherapy
Intensity Modulated RadioTherapy A clinical application of a small accelerator University Medical Center Groningen A.A. van t Veld PhD I. Hoveijn PhD part 1 part2 CERN/KVI accelerator school, Zeegse, June
More informationABAS Atlas-based Autosegmentation
ABAS Atlas-based Autosegmentation Raising contouring to the next level Simultaneous Truth and Performance Level Estimation (STAPLE) Unique to ABAS, the STAPLE calculation is more robust than simple averaging.
More informationNational Cancer Statistics in Korea, 2014
National Cancer Statistics in Korea, 2014 2016. 12. 20. Korea Central Cancer Registry Cancer Incidence in Korea, 2014 National Cancer Incidence, 2014 Trends in Cancer Incidence by Sex and Year * Dark colored
More informationIn-Room Radiographic Imaging for Localization
In-Room Radiographic Imaging for Localization Fang-Fang Yin, Zhiheng Wang, Sua Yoo, Devon Godfrey, Q.-R. Jackie Wu Department of Radiation Oncology Duke University Medical Center Durham, North Carolina
More informationWhich Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic
Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic Outline Image quality and image dose Free breathing CT, 4DCT, and synthetic
More informationStereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations
Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife State-of of-the-art and New Innovations Chad Lee, PhD CK Solutions, Inc. and CyberKnife Centers of San Diego Outline Basic overview
More informationThe High-End Solution for Real-Time Patient Tracking
The High-End Solution for Real-Time Patient Tracking You trust your planning and delivery systems to constantly achieve the best possible results. Now you can trust the Catalyst to provide the same level
More informationCredentialing for the Use of IGRT in Clinical Trials
Credentialing for the Use of IGRT in Clinical Trials James M. Galvin, DSc Thomas Jefferson University Hospital Jefferson Medical College Philadelphia, PA and The Radiation Therapy Oncology Group RADIATION
More informationIMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor
IMRT/IGRT Patient Treatment: A Community Hospital Experience Charles M. Able, Assistant Professor Disclosures I have no research support or financial interest to disclose. Learning Objectives 1. Review
More informationAre Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?
Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program? Can you currently use direct documentation and measurement of delivered dose to ensure you did not underdose or
More informationWhat do we Know About Adaptive Radiotherapy? Lei Dong, Ph.D. Scripps Proton Therapy Center San Diego, California
What do we Know About Adaptive Radiotherapy? Lei Dong, Ph.D. Scripps Proton Therapy Center San Diego, California AAMD Region II Meeting Houston, Texas September 13-14, 2012 Learning Objectives To gain
More informationVOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER
Romanian Reports in Physics, Vol. 67, No. 3, P. 978 986, 2015 VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER D. ADAM 1, 2, M.D. SUDITU 1, 2, R. POPA 1, 2, V. CIOCALTEI
More informationI. Equipments for external beam radiotherapy
I. Equipments for external beam radiotherapy 5 linear accelerators (LINACs): Varian TrueBeam 6, 10 & 18 MV photons, 6-18 MeV electrons, image-guided (IGRT) and intensity modulated radiotherapy (IMRT),
More informationIGRT/Adaptive Gating
IGRT/Adaptive Gating unlocking possibilities exceeding limits with confidence PIONEERING IGRT BrainLAB is committed to providing the best radiotherapy solutions for better treatment and patient care. BrainLAB
More informationIMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia
IMRT - the physician s eye-view Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia The goals of cancer therapy Local control Survival Functional status Quality of life Causes
More informationA UNIQUELY SMART RADIATION THERAPY SYSTEM
A UNIQUELY SMART RADIATION THERAPY SYSTEM FULLY INTEGRATED TREATMENT PLANNING AND DELIVERY PLAN Accuray Precision Treatment Planning System As the radiation oncology field advances, interoperability is
More informationCan we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?
Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Dimos Baltas Dept. of Medical Physics & Engineering, Strahlenklinik, Klinikum Offenbach GmbH 63069 Offenbach, Germany
More informationSarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington
Sarcoma and Radiation Therapy Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington Objective: Helping you make informed decisions Introduction Process Radiation
More informationA Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer
A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer Tony Kin Ming Lam Radiation Planner Dr Patricia Lindsay, Radiation Physicist Dr John Kim, Radiation Oncologist Dr Kim Ann Ung,
More informationTechnical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.
Technical Study Stereotactic Radiosurgery with Elekta Versa HD and Monaco Accuracy of a single isocenter, multiple brain metastases VMAT plan delivered to a pseudo-patient dosimetric gel phantom Institution
More informationRadiotherapy physics & Equipments
Radiotherapy physics & Equipments RAD 481 Lecture s Title: An Overview of Radiation Therapy for Health Care Professionals Dr. Mohammed Emam Vision :IMC aspires to be a leader in applied medical sciences,
More informationCyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017
CyberKnife Technology in Ablative Radiation Therapy Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017 Objectives Components and work flow of CyberKnife Motion management of CyberKnife
More informationA UNIQUELY SMART RADIATION THERAPY SYSTEM
A UNIQUELY SMART RADIATION THERAPY SYSTEM FULLY INTEGRATED TREATMENT PLANNING AND DELIVERY PLAN Accuray Precision Treatment Planning System As the radiation oncology field advances, interoperability is
More informationElectron Beam ET - Reloaded Therapy - Reloaded
8/4/216 Electron Beam ET - Reloaded Therapy - Reloaded Qiuwen Wu, Ph.D. Department of Radiation Oncology Duke University 1 Introduction: e vs. γ vs. p Electron Photon Proton Depth dose and lateral profiles
More informationSRS Uncertainty: Linac and CyberKnife Uncertainties
SRS Uncertainty: Linac and CyberKnife Uncertainties Sonja Dieterich, PhD Linac/CyberKnife Technological Uncertainties 1 Linac Mechanical/Radiation Isocenters Depuydt, Tom, et al. "Computer aided analysis
More information3D-CRT Breast Cancer Planning
3D-CRT Breast Cancer Planning Tips and Tricks Bednář, V. 3D-CRT Obsolete or not? There are more advanced techniques than 3D-CRT, but 3D-CRT has some advantages: Availability and price Forward planning
More informationRadiation treatment planning in lung cancer
Radiation treatment planning in lung cancer Georg Dietmar 1,2 1 Div. Medical Rad. Phys., Dept. of Radiation Oncology / Medical Univ. Vienna & AKH Wien 2 Christian Doppler Laboratory for Medical Radiation
More informationImage Guided Proton Therapy and Treatment Adaptation
Image Guided Proton Therapy and Treatment Adaptation www.hollandptc.nl d.r.schaart@tudelft.nl Cancer in The Netherlands About 1 in 3 people get cancer in some stage of their life 86.800 new cancer patients
More informationImpact of MLC properties and IMRT technique in meningioma and head-and-neck treatments
Kantz et al. Radiation Oncology (2015) 10:184 DOI 10.1186/s13014-015-0447-z RESEARCH Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments Steffi Kantz 1*, Matthias Söhn
More informationA VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI
More informationCollimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region
Li et al. Radiation Oncology (2015) 10:235 DOI 10.1186/s13014-015-0544-z METHODOLOGY Open Access Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution
More informationWork partially supported by VisionRT
Work partially supported by VisionRT Background of frameless intracranial stereotactic radiosurgery UCSD SRS/SRT procedure Clinical Results Summary Total prescribed doses : order of 10 50 Gy Planning targets
More informationElekta 2017 Australasian User Meeting 12 th November 2017, Newcastle, NSW
This work aims to compare ITVs defined using 4DCBCT data in two treatment planning systems (TPS) and to assess their impact on planned dose Elekta 2017 Australasian Background: Lung SABR in NT Introduction:
More information