For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Size: px
Start display at page:

Download "For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns."

Transcription

1 For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns

2 The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies over traditional, fully porous sub- columns on the market, yielding remarkable chromatographic resolution, higher peak capacities, and greater sensitivity, so labs can get the most out of every UHPLC analysis. If you are not completely satisfied with Kinetex core-shell columns, send in your comparative data to a similar product within days for a FULL REFUND.

3 The Core-Shell Advantage Using sol-gel processing techniques that incorporate nano-structuring technology, a durable, homogeneous porous shell is grown on a solid silica core to create a core-shell particle. This particle morphology results in less band broadening for all four sources of UHPLC band broadening compared to fully porous particles and thus delivers extremely high efficiencies! Kinetex Core-Shell Fully Porous Less Band Broadening More Band Broadening Kinetex Core-Shell High particle density helps create optimal bed structure which reduces band broadening effects of Eddy Diffusion Ultra-high performance on UHPLC systems Reduced diffusion path improves efficiency Solid Core Porous Shell Fully Porous Less homogenuous bed structure leads to performance loss Diffusion path limits efficiencies Band broadening due to frictional heating as flow rate increases Phenomenex l WEB:

4 High Performance UHPLC Core-Shell Particles Kinetex. Sub- efficiencies at much lower backpressures Gives you the opportunity to increase flow rate for increased peak capacities and shorter run times Can be used on both UHPLC and HPLC systems. Kinetex. 0 % higher performance than traditional. fully porous particle First core-shell sub- on the market. Kinetex. Incredible column efficiencies above 00,000 p/m, giving an average of 0 % higher efficiencies than traditional. fully porous particles Second core-shell sub- on the market. Other Core-Shell Solutions... Kinetex While not developed specifically for UHPLC systems, the Kinetex provides or better efficiencies at backpressures and is fully scalable to the other Kinetex particle sizes! Aeris Columns Aeris WIDEPORE and PEPTIDE columns are excellent tools for UHPLC analysis of proteins and peptides! solid core.---. solid core.---. solid core

5 UHPLC Compatible Kinetex Columns are Compatible with All UHPLC Instruments Kinetex on Agilent 90 Kinetex on JASCO X-LC Kinetex on Shimadzu Nexera Kinetex on Waters ACQUITY UPLC Need help installing your Kinetex column? Waters, ACQUITY and UPLC are registered trademarks of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. Shimadzu and Nexera are registered trademarks of Shimadzu Corporation. JASCO is a registered trademark of JASCO Corporation. Phenomenex is not affiliated with Agilent, JASCO, or Waters. Phenomenex l WEB:

6 Kinetex.. Beyond Fully Porous Sub- Performance With its ability to provide ultra-high performance at a fraction of the pressure, the Kinetex. paves the way for better, faster UHPLC methods. Where Your UHPLC Performance Stops... Waters ACQUITY. 0. ml/min and 9 bar Peak Capacity of Ours Starts... Kinetex. 8 9 min 9 0 App ID ml/min and bar Peak Capacity of 8 App ID 00 Conditions same for all columns except where noted: Columns: Kinetex. C8 ACQUITY UPLC BEH. C8 Dimensions: 00 x. mm Mobile Phase: A: 0.% Formic Acid in Water B: 0.% Formic Acid in Acetonitrile Gradient: Time (min) % B 9 9 Flow Rate: As Noted Detection: nm Backpressure: As Noted Instrument: Waters ACQUITY UPLC Sample:. Pyridine. Acetaminophen. Pindolol. Sulfathiazole. Acebutolol. Chloropheniramine. Benzyl Alcohol 8. Phenol 9. Triprolidine 0. -Methyl, -nitrobenzoic acid. Nortriptyline. Prednisolone. Diflunisal. -Hydroxy, -methyl benzaldehyde. Hexanophenone 0 min... And Keeps Going! Kinetex..0 ml/min and 8 bar Peak Capacity of ,9 min App ID 000 Faster Analysis Higher Performance On Your UHPLC System Waters, ACQUITY, and UPLC are registered trademarks of Waters Corporation. BEH Technology is a trademark of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications.

7 Kinetex. Do More with Core-Shell! Start by matching a Kinetex. column to the sub- you re currently using. Then watch the pressure drop and you re options appear. In no time you ll have better peak capacities, sensitivities, and greater column performance. 98 Intensity, cps Intensity, cps.e.0e e.e Fully Porous. C8 00 psi ( bar) Peak Capacity =. App ID min Kinetex. C8 00 psi ( bar) Peak Capacity = min Lower backpressure gives you options App ID 99 Conditions are the same for all columns: Column: Kinetex. μm C8 Fully Porous. μm C8 Dimensions: Kinetex: 0 x. mm, 0 x. mm, and 00 x. mm Fully Porous: 0 x. mm Flow Rate: 0.8, 0.8,., and 0.8 ml/min Mobile Phase: A: 0.% Formic acid in Water B: 0.% Formic acid in Acetonitrile Gradient: Time (min) % B Temperature: 0 ºC Detection: MS Backpressure: As noted Analytes:. Haloperidol. Diltiazem. Terfenadine. Cimetidine. Acetaminophen. Sulfathiazole. Pindolol 8. Quinidine 9. Acebutolol 0. Chlorpheniramine. Tripolidine. Prednisolone. Nortriptyline. -Hydroxy--methyl benzaldehyde. Hexanophenone Increase the flow rate Kinetex. C8 98.e Increase peak capacity Increase column length Kinetex. C8.08e Increase potential resolving power Intensity, cps.0e psi ( bar) 90 Peak Capacity =. 8 App ID min Intensity, cps.00e psi ( bar) Peak Capacity = min App ID 990 Phenomenex l WEB:

8 Kinetex.. The First Sub- Core-Shell Column Upgrade the efficiency and performance of your current sub- column with a Kinetex. core-shell column. Extra resolution, higher peak capacities, and greater sensitivity are all within your reach with Kinetex Core-Shell Technology. AU % 8 % % Higher Resolution (between peaks and ) Higher Resolution (between peaks and ) Higher Resolution (between peaks and 8) AU min Waters ACQUITY BEH. C8 App ID 980 Conditions for both columns: Column: Kinetex. XB-C8 ACQUITY UPLC BEH. C8 Dimensions: 0 x. mm Mobile Phase: A: Milli-Q Water B: Acetonitrile Gradient: Time (min) % B Flow Rate: 0. ml/min Temperature: Ambient Detection: 0 nm (ambient) Backpressure: 89 bar (Kinetex) 9 bar (ACQUITY) Instrument: Waters ACQUITY UPLC Sample:. Hydrocortisone. Cortisone. Corticosterone. Cortisone--Acetate. DHEA (Dehydroepiandrosterone). -Hydroxyprogesterone. Deoxycorticosterone 8. Progesterone App ID 980 min Waters, ACQUITY, and UPLC are registered trademarks of Waters Corporation. BEH Technology is a trademark of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications.

9 Kinetex. Superior Resolving Power The increased efficiency of the Kinetex. allows you to use shorter columns for faster run times while keeping optimal performance. Now it s time for you to challenge your difficult separations with the superior efficiency and resolving power of a Kinetex. core-shell column. Fully Porous. C8 Intensity, cps min.e Fused-Core. C8 Intensity, cps min Intensity, cps.e Kinetex. Faster analysis, better sensitivity, and overall better resolution! App ID min Conditions for all columns Columns: Fully porous. C8 (0 x. mm) Fused-Core. C8 (0 x. mm) Kinetex. C8 (0 x. mm) Mobile Phase: A: 0 mm Ammonium Formate B: Acetonitrile Gradient: Time (min) % B Flow Rate: 0. ml/min Temperature: º C Detection: MS/MS (AB SCIEX API 000 ) Sample:. Lorazepam glucoronide Fused-Core is a registered trademark of Advanced Materials Technology, Inc. Phenomenex is in no way affiliated with Advanced Materials Technology, Inc. Comparative separations may not be representative of all applications. Phenomenex l WEB:

10 Kinetex.. The New Standard for UHPLC Bring your UHPLC analysis to the next level with the incredibly powerful Kinetex.. Kinetex. C8 mau Peak Capacity = 8 App ID 08 Higher Sensitivity 0 min mau Waters ACQUITY UPLC BEH. C Peak Capacity = App ID 08 Greater Resolution of Impurities 0 min Conditions for both columns: Column: Kinetex. C8 ACQUITY UPLC BEH. C8 Dimensions: 0 x. mm Mobile Phase: Acetonitrile / Water (0:0) Gradient: Time (min) % B Flow Rate: 0. ml/min Temperature: Ambient Detection: nm Instrument: Waters ACQUITY UPLC Sample:. -Gingerol (). -Gingerol (). Capsaicin. 8-Gingerol. -Shogal. 0-Gingerol. 8-Shogal 8. 0-Shogal BEH. μm Kinetex. μm Waters, ACQUITY, and UPLC are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications. 8

11 Kinetex. More Peaks and More Sensitivity, in Less Time With typically 0 % more efficiency then a fully porous. particle, the Kinetex. lets you SEE MORE! Waters ACQUITY BEH. C8 AU 0. 8 Peaks App ID Min Kinetex 9. C8 AU Peaks App ID 9 Min Conditions for all columns same except where noted: Column: Waters ACQUITY UPLC BEH. C8 Kinetex. C8 Dimensions: 0 x. mm Mobile Phase: A: 0. % TFA in Water B: 0. % TFA in Acetonitrile Gradient: Time (min) % B Flow Rate: 0. ml/min Temperature: 0 º C Detection: 0 nm (ambient) Instrument: Waters ACQUITY UPLC Sample: Trypsin digested BSA Waters, ACQUITY, and UPLC are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications. Phenomenex l WEB: 9

12 Kinetex.. More Resolution! Kinetex. Core-Shell Technology will show you what you re missing with conventional sub- fully porous columns. Waters ACQUITY BEH. C8 8 AU min AU min App ID 8 Kinetex. C8 AU More Resolution! min AU App ID min Conditions for all columns same except where noted: Column: Waters ACQUITY UPLC BEH. Gradient: Time (min) % B C8 0 Kinetex. C8.0 9 Dimensions: 0 x. mm. 9 Mobile Phase: A: 0. % Formic Acid in Water. B: 0. % Formic Acid in Acetonitrile Flow Rate: 0. ml/min Temperature: Ambient Detection: nm Instrument: Waters ACQUITY UPLC Sample:. Estriol. Hydrocortisone. Corticosterone. Cortisone acetate. -beta-estradiol. -alpha-estradiol. -OH-progesterone 8. -alpha-ethynylestradiol 9. Estrone 0. Deoxycorticosterone acetate. Progesterone Waters, ACQUITY, and UPLC are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications. 0

13 UHPLC Column Protection R&D 00 Award Recipient Protect any UHPLC column Protect your column, including Kinetex core-shell columns, from damaging contaminants and microparticulates with the SecurityGuard ULTRA guard cartridge system! Simple to use Extend column lifetime Pressure rated to 0,000 psi (,8 bar) Fits virtually all manufacturers columns. to. mm ID UHPLC Column Protection SecurityGuard ULTRA Guard Cartridge System (Cartridge connected to Holder) Cartridge* Frit Holder Material Chamber Compounds of Interest } Contaminants and Particulates *Cartridge schematic not drawn to scale See it in action: Phenomenex l WEB:

14 Six selectivities. Take your pick. Choose from a wide range of phases for greater flexibility in UHPLC method development. Kinetex columns come in a variety of stationary phases to cover a full spectrum of applications ranging from acids and bases, to isomers and extremely polar compounds. Si C8 XB- C8 C8 Endcapped C8 phase Increased retention for polar basic compounds Protective isobutyl side chains Increased retention of polar acidic compounds Endcapped C8 phase Less hydrophobic than a C8 phase F ACN H 0 ACN ACN ACN ACN ACN ACN ACN F F ACN ACN ACN ACN H 0 ACN ACN ACN ACN H 0 H 0 H 0 F F H 0 HO O H 0 OH H 0 H 0 O H 0 Si H 0 OH Si HO Si H 0 HO OH Phenyl- Hexyl PFP HILIC Phenyl - Hexyl Greater retention and separation of aromatic hydrocarbons Pentafluorophenyl phase Unique aromatic and polar selectivity Unbonded silica phase Increased retention of polar compounds Material Characteristics Packing Material Pore Size (Å) Effective Surface Area (m /g) Effective Carbon Load % USP Classification ph Stability* Pressure Stability Kinetex C L. - 8.* 000 bar** Kinetex XB-C L. - 8.* 000 bar** Kinetex C L. - 8.* 000 bar** Kinetex PFP L. - 8.* 000 bar** Kinetex HILIC L bar** Kinetex Phenyl-Hexyl L. - 8.* 000 bar** *Columns are ph stable from.-0 under isocratic conditions. Columns are ph stable.-8. under gradient conditions. **Kinetex. columns of.0 and. mm ID are pressure rated to 00 bar.

15 Kinetex Ordering Information. Minibore Column (mm) Phases 0 x. C8 00B--AN SecurityGuard. μm Minibore Columns (mm) Ultra Cartridges Phases 0 x. 0 x. 00 x. 0 x. /pk XB-C8 00A-98-AN 00B-98-AN 00D-98-AN 00F-98-AN AJ0-88 C8 00A--AN 00B--AN 00D--AN 00F--AN AJ0-88 C8 00A-99-AN 00B-99-AN 00D-99-AN 00F-99-AN AJ0-88 PFP 00A--AN 00B--AN 00D--AN 00F--AN AJ0-88 HILIC 00A--AN 00B--AN 00D--AN AJ0-88 Phenyl-Hexyl 00B-00-AN 00D-00-AN 00F-00-AN AJ0-888 for. mm ID R&D 00 Award Recipient SecurityGuard. μm MidBore Columns (mm) Ultra Cartridges Phases 0 x.0 0 x.0 00 x.0 /pk XB-C8 00A-98-Y0 00B-98-Y0 00D-98-Y0 AJ0-8 C8 00B--Y0 00D--Y0 AJ0-8 C8 00A-99-Y0 00B-99-Y0 00D-99-Y0 AJ0-8 PFP 00B--Y0 00D--Y0 AJ0-880 HILIC 00B--Y0 AJ0-89 Phenyl-Hexyl AJ0-88 for.0 mm ID SecurityGuard. μm Minibore Columns (mm) Ultra Cartridges Phases 0 x. 0 x. x. 00 x. 0 x. /pk XB-C8 00A-9-AN 00B-9-AN 00C-9-AN 00D-9-AN 00F-9-AN AJ0-88 C8 00A--AN 00B--AN 00C--AN 00D--AN 00F--AN AJ0-88 C8 00A-9-AN 00B-9-AN 00C-9-AN 00D-9-AN 00F-9-AN AJ0-88 PFP 00A--AN 00B--AN 00C--AN 00D--AN 00F--AN AJ0-88 HILIC 00A--AN 00B--AN 00C--AN 00D--AN 00F--AN AJ0-88 Phenyl-Hexyl 00A-9-AN 00B-9-AN 00C-9-AN 00D-9-AN 00F-9-AN AJ0-888 for. mm ID SecurityGuard. μm MidBore Columns (mm) Ultra Cartridges Phases 0 x.0 0 x.0 x.0 00 x.0 0 x.0 /pk XB-C8 00A-9-Y0 00B-9-Y0 00C-9-Y0 00D-9-Y0 00F-9-Y0 AJ0-8 C8 00A--Y0 00B--Y0 00C--Y0 00D--Y0 00F--Y0 AJ0-8 C8 00A-9-Y0 00B-9-Y0 00C-9-Y0 00D-9-Y0 00F-9-Y0 AJ0-8 PFP 00A--Y0 00B--Y0 00C--Y0 00D--Y0 00F--Y0 AJ0-880 HILIC 00A--Y0 00F--Y0 AJ0-89 Phenyl-Hexyl 00D-9-Y0 00F-9-Y0 AJ0-88 for.0 mm ID SecurityGuard. μm Analytical Columns (mm) Ultra Cartridges Phases 0 x. 0 x. x. 00 x. 0 x. /pk XB-C8 00B-9-E0 00C-9-E0 00D-9-E0 00F-9-E0 AJ0-88 C8 00A--E0 00B--E0 00C--E0 00D--E0 00F--E0 AJ0-88 C8 00B-9-E0 00C-9-E0 00D-9-E0 00F-9-E0 AJ0-80 PFP 00A--E0 00B--E0 00C--E0 00D--E0 00F--E0 AJ0-8 HILIC 00B--E0 00C--E0 00D--E0 00F--E0 AJ0-8 Phenyl-Hexyl 00B-9-E0 00C-9-E0 00D-9-E0 00F-9-E0 AJ0-8 for. mm ID SecurityGuard ULTRA cartridges require holder, Part No. AJ Find Kinetex analytical and preparative dimensions online at: Phenomenex l WEB:

16 Australia t: f: Austria t: f: Belgium t: (French) t: 0 8 (Dutch) f: + (0)0-89 beinfo@phenomenex.com Canada t: (800) -8 f: (0) 8-8 info@phenomenex.com Denmark t: f: + 80 nordicinfo@phenomenex.com Finland t: f: + 80 nordicinfo@phenomenex.com France t: f: franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: f: 00-0 indiainfo@phenomenex.com Ireland t: 0 0 f: eireinfo@phenomenex.com Italy t: 0 f: 0 italiainfo@phenomenex.com Luxembourg t: + (0)0-800 f: + (0)0-89 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: f: + 80 nordicinfo@phenomenex.com Puerto Rico t: (800) -HPLC f: (0) 8-8 info@phenomenex.com Sweden t: f: + 80 nordicinfo@phenomenex.com United Kingdom t: 0-0 f: 0-09 ukinfo@phenomenex.com United States t: (0) -0 f: (0) 8-8 info@phenomenex.com All other countries: Corporate Office USA t: (0) -0 f: (0) 8-8 info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR0_W Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Phenomenex and Kinetex are registered trademarks, and MidBore and SecurityGuard are trademarks of Phenomenex. Waters, ACQUITY, and UPLC are registered trademarks, and BEH Technology is trademark of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. API 000 is a trademark of AB SCIEX Ltd. Shimadzu and Nexera are registered trademarks of Shimadzu Corporation. JASCO is a registered trademark of JASCO Corporation. Fused-Core is a registered trademark of Advanced Materials Technology, Inc. Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany. Disclaimer Phenomenex is not affiliated with Advanced Materials Technology, Agilent Technologies, JASCO, or Waters Corporation. Comparative separations may not be representative of all applications. 0 Phenomenex, Inc. All rights reserved.

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Effective Surface Area (m 2 /g) Pore Size (Å)

Effective Surface Area (m 2 /g) Pore Size (Å) n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

Vitamin Testing APPLICATIONS GUIDE

Vitamin Testing APPLICATIONS GUIDE Vitamin Testing APPLICATIONS GUIDE Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method

More information

2012 Waters Corporation 1

2012 Waters Corporation 1 An Introduction to Waters HPLC and ACQUITY UPLC Column Technologies for small molecule analysis Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 5659 6288 Fax: +358-9-5659 5659 6282 Waters Finland

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

World Renowned HPLC Media Reinvented for UHPLC!

World Renowned HPLC Media Reinvented for UHPLC! OMEGA World Renowned HPLC Media Reinvented for UHPLC! New. µm Staggering UHPLC Efficiencies and Performance Extreme Ruggedness and Mechanical Strength Perfect Complement to Kinetex Core-Shell Technology

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE APPLICATINS Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE Sky Countryman, Shahana Huq, Terrell Mathews, et al. Phenomenex,

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

An Easier QuEChERS Solution for Diverse Matrices. Learn more at An Easier QuEChERS Solution for Diverse Matrices Learn more at www.phenomenex.com/roq What is roq QuEChERS? QuEChERS is a descriptive acronym that stands for Quick, Easy, Cheap, Effective, Rugged, and

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Separations. Sweet Sugar. Are in Your Future. New.   Luna Omega SUGAR LC Column OMEGA OMEGA Sweet Sugar Separations Are in Your Future New Luna Omega SUGAR LC Column Improved carbohydrate retention and separation with novel HILIC selectivity Enhanced lifetime with highly robust and efficient

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing

More information

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED

More information

The Raptor HILIC-Si Column

The Raptor HILIC-Si Column The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview ABSTRACT: S. M. Ramdharane 1, K. B. Vyas 2, K. S. Nimavat 3 * 1 Pacific Academy of Higher Education & Research

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

Studies on Stationary Phase Selectivity for Solid-Core Particles

Studies on Stationary Phase Selectivity for Solid-Core Particles Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com

More information

TN-0116 Scott Krepich

TN-0116 Scott Krepich TN-116 APPLICATIONS Analysis of Perfluorinated Compounds (PFCs) in Aqueous Matrices, Evaluating Various Online SPE Sorbents by LC-MS/MS Scott Krepich Senior Field Application Scientist Scott enjoys surfing

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

Reversed-Phase Columns (Other than ODS)

Reversed-Phase Columns (Other than ODS) 7 Reversed-Phase Columns (ther than DS) Types and characteristics of reversed-phase columns -- 9, 9 YMC-Pack Pro C8, C--------------------------- 96 YMC-Pack C 8 --------------------------------------

More information

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania

More information

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity Selectivity Accelerated Stationary Phase: Biphenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor Biphenyl Column With Raptor

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

GlycanPac AXR-1 Columns

GlycanPac AXR-1 Columns CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

The One Minute Chromatographer

The One Minute Chromatographer The One Minute Chromatographer Agilent Technologies, Inc. 2013 Page 1 Sub 1 Minute Separations with RRHD Columns Agilent ZORBAX RRHD SB-C18, 2.1 x 100mm, 1.8 µm H2O (0.05% Formic acid) / 2-98 % Acetonitrile

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles

More information

InertSustainBio C18. Rapid Separations of Proteins and Peptides

InertSustainBio C18. Rapid Separations of Proteins and Peptides InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight

More information

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design Alan P McKeown amckeown@ace-hplc.com Advanced Chromatography Technologies www.ace-hplc.com www.mac-mod.com Outline 2 Chromatographic

More information

Fortis Method Development Options

Fortis Method Development Options Method Dev Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options Fortis Ho - Polar endcapped C8 - Increased

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Method development of cytotoxic drugs selectivity IAC Seminar, 06.03.2015 Content Introduction Definition

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information