Preparative Chromatography Meets UHPLC

Size: px
Start display at page:

Download "Preparative Chromatography Meets UHPLC"

Transcription

1 Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure

2 Two Award Winning Technologies Award Recipient AXIA Award Recipient Kinetex NOW COMBINED to give you unmatched purification performance for both HPLC and SFC applications. Core-Shell Technology Kinetex Core-Shell Technology produces increased efficiencies over traditional, fully porous columns, yielding remarkable chromatographic resolution, higher peak capacities, and greater sensitivity, so labs can get even more out of their HPLC analyses! The benefits of Kinetex Core-Shell Technology include: Increased efficiencies over traditional fully porous columns Seamless scalability from HPLC/UHPLC to Preparative LC Kinetex µm provides better performance than traditional fully porous and µm materials. µm.7 µm.6 µm µm Preparative Column Packing Technology An advanced preparative column packing and hardware design, Axia incorporates patented Hydraulic Piston Compression technology that offers increased sorbent bed density and eliminates media bed collapse as a source of premature column failure in preparative HPLC columns. Unlike traditional column packing methods, the Axia packing method is completely automated and monitored by multiple sensors to allow for measurement and recording of all process parameters for every column. The result is a vastly improved packing process that offers the following benefits: Extended column lifetimes Improved reproducibility: Column-to-Column and Batch-to-Batch Efficiencies and peak symmetries on par with analytical separations Increased column stability under high flow rates

3 Combining These Two Award Winning Technologies Gives You Higher Efficiency! Start with sharper peaks by taking advantage of the high efficiencies of Kinetex µm Axia preparative columns. Waters XBridge µm C8 Prep OBD Kinetex µm XB-C8 Axia Packed Response - Millivolts 4 x 9. mm N =, plates App ID 46 Response - Millivolts 4 x. mm N = 8,4 plates Over % Increase in Efficiency App ID min min Conditions for both columns: Columns: Kinetex µm XB-C8 Axia Packed XBridge µm C8 Prep OBD Dimensions: x. mm (Kinetex) x 9 mm (XBridge) Mobile Phase: Water/ Acetonitrile (:) Injection Volume: µl Flow Rate: ml/ min Temperature: Ambient Detection: 4 nm Sample:. Uracil. Acetophenone. Toluene 4. Naphthalene Excellent Loadability! With narrower peak widths than fully porous columns across every sample load, Axia packed Kinetex µm columns give you the capability of increased sample load and higher throughput for vastly improved purification performance and economics. 77 Waters XBridge µm C8 Prep OBD mv min Conditions for both columns: Columns: Kinetex μm C8 Axia Packed XBridge µm C8 Prep OBD Dimensions: x. mm (Kinetex) x 9 mm (XBridge) Mobile Phase: A: Water with. % Formic acid B: Acetonitrile with. % Formic acid Gradient: Time (min) 8 % B App ID 77 mv Kinetex µm C8 Axia Packed Increased Sensitivity and Excellent Loadability! min Flow Rate: ml/min Temperature: Ambient Detection: 4 nm Sample: mg/ml in DMSO. Doxepin (From - mg on-column). Amitriptyline (From - mg on-column) App ID 774 Waters is a registered trademark of Waters Corp. OBD and XBridge are trademarks of Waters Corp. Phenomenex is in no way affiliated with Waters Corp. Comparative separations may not be representative of all applications.

4 Preparative Technology Redefined Axia Technology Vs. Traditional Prep Column Packing Waters OBD Patented Prep Column Packing Process: TRADITIONAL PREP PACKING In traditional slurry packing processes, like the Waters OBD (Optional Bed Density) Prep column packing approach, pressure on the packed bed is released when the column is removed from the column packing station to allow attachment of the endfitting. This conventional packing process involves: Compression Decompression Recompression Several problems with this packing method are: Variability in column performance due to increased number of manual operations required for assembly Potential silica media damage during recompression Limited level of process control is based on traditional slurry packing technology Pump Column Media escapes from disconnected column Silica media packed under liquid pressure Removal of escaped media Violent recompression of silica media Media density disruption and potential media crushing Diagram from Waters Corporation U.S. Patent No. 7,99,4 Our Vastly Improved Patented Packing Process: AXIA TECHNOLOGY In contrast to the multi-step process required in conventional slurry packing, Axia packed preparative columns are packed using a single axial compression step. The ideal column bed density is custom calculated and automated for each specific media and column size. Computer control of the entire process ensures both proper bed density and column uniformity every time. During the Axia packing process, the packing piston is locked in place, eliminating any de compression and recompression of the packed bed. This improves media integrity and column bed stability, and solves the primary lifetime and performance problems associat ed with conventional slurry packed preparative columns. Silica media packed under piston pressure Column Specialized computer control for ideal pressure Packing piston locked. No media or pressure escape Media maintains initial optimal packing density and shape Axia patent: U.S. Patent No. 7,674,8 Waters is a registered trademark of Waters Corp. OBD is a trademark of Waters Corp. Phenomenex is in no way affiliated with Waters Corp. 4

5 The Packing Difference You Can See! Traditional Prep Packing Decompression and then recompression during packing can damage the media and lead to increased column-to-column variability, flow disturbances, and decreased column lifetimes. *SEM of Waters OBD inlet frit Crushed media or silica fines at frit surface after packing Axia Packing Technology Highly tuned patented process and hardware eliminates potential decompression and ensures media stability and optimal bed density. *SEM of Axia inlet frit Intact media at frit surface after packing *The images are believed to be representative, but individual columns may vary. View an animated packing process comparison Unmatched Column Reproducibility The completely automated Axia packing system provides feedback control and infinite tuning of packing density for specific media characteristics such as mechanical strength and porosity. An optimum bed density can be consistently reproduced column-to-column. This directly translates into consistent efficiency and peak asymmetry measurements and decreases the column variability seen in traditionally packed preparative columns. Efficiency (N),, 8, Reproducible Column-to-Column Efficiency Average Efficiency (N) with Synergi 4 µm Hydro-RP x. mm.8 % RSD. 7 % Improved Avg. Efficiency Peak Asymmetry.4.. Reproducible Column-to-Column Peak Asymmetry Average Peak Asymmetry with Gemini µm C8 x. mm 9. % RSD % Improved Avg. Peak Shape. Density (%) Density Comparison of Packed Beds 9 % Increase in Packing, density and More Uniformly Packed Bed 6,. 4 4, Traditional Slurry Packing Axia Packed Hydraulic Piston Compression Packing Traditional Slurry Packing Axia Packed Hydraulic Piston Compression Packing Traditional Slurry Packing Axia Packed Hydraulic Piston Compression Packing Waters is a registered trademark of Waters Corp. OBD is a trademark of Waters Corp. Phenomenex is in no way affiliated with Waters Corp. Comparative separations may not be representative of all applications.

6 Seamless Scalability from HPLC/UHPLC to PREP The recent addition of the Kinetex µm in the Axia packed format (. mm ID) makes it the first core-shell sorbent commercially available for small-scale preparative applications. Combine this with the added flexibility that the entire Kinetex core-shell line (. µm,.7 µm,.6 µm and μm) is fully scalable in retention and selectivity, makes transferring high performance HPLC/ UHPLC methods to preparative and SFC applications, simple. Analytical method Kinetex.6 μm XB-C8 mau App ID 4 Column: Kinetex.6 µm XB-C8 Dimensions: x 4.6 mm Part No.: F-4496-E Mobile Phase: A:.% TFA in Water B:.% TFA in Acetonitrile Gradient: Linear 8: (A/B) to :9 (A/B) over minutes Injection Volume: µl Flow Rate: ml/ min Temperature: Ambient Detection: nm Sample: Crude peptide mix min Preparative scale-up and fraction collection Kinetex μm XB-C8 mv 7 7 FR FR FR FR 4 App ID 44 Column: Kinetex µm XB-C8 Axia Packed Dimensions: x. mm Part No.: F-46-P-AX Mobile Phase: A:.% TFA in Water B:.% TFA in Acetonitrile Gradient: Linear 8: (A/B) to :9 (A/B) over minutes Injection Volume: ml Flow Rate: ml/ min Temperature: Ambient Detection: nm Sample: Crude peptide mix min Analytical fraction analysis Kinetex.6 μm XB-C8 Fraction = 97. % Purity Fraction 4 Fraction Fraction Fraction App ID 4 Column: Kinetex.6 µm XB-C8 Dimensions: x 4.6 mm Part No.: F-4496-E Mobile Phase: A:.% TFA in Water B:.% TFA in Acetonitrile Gradient: Linear 8: (A/B) to :9 (A/B) over minutes Injection Volume: µl Flow Rate: ml/ min Temperature: Ambient Detection: nm Sample: Crude peptide mix min Tip: For more information on the power of Kinetex core-shell scalability, request technical note TN- at: 6

7 A Broad Spectrum of Column Selectives Kinetex core-shell columns are available in a wide range of stationary phases, allowing you to optimize your separation for maximum resolution and loadability across HPLC, UHPLC, and Preparative HPLC and SFC applications. 9 4 C8 6 4 App ID min C8 min Endcapped C8 phase Increased retention for polar basic compounds XB-C8 6 4, Si App ID 9 XBC8 min min Protective isobutyl side chains Increased retention of polar acidic compounds 86, 6 4 Phenyl-Hexyl App ID 994 6, PhenylHexyl Phenyl-Hexyl Greater retention and separation of aromatic hydrocarbons min F,4 F PFP 6 F F F App ID Conditions for all columns: Column: Kinetex.6 µm C8 Kinetex.6 µm XB-C8 Kinetex.6 µm Phenyl-Hexyl Kinetex.6 µm PFP Dimensions: x. mm Mobile Phase: A:.% Formic acid in Water B:.% Formic acid in Acetonitrile Gradient: Time (min) %B Flow Rate: Temperature: Detection: Sample: PFP Pentafluorophenyl phase Unique aromatic and polar selectivity min.8 ml/min ºC 4 nm (ambient). Pyridine. Triprolidine. Acetaminophen. Nortriptyline. Pindolol. Prednisolone 4. Quinidine. -Methyl. Sulfathiazole 4-nitrobenzoic acid 6. Acebutolol 4. -Hydroxy7. Benzyl alcohol -methylbenzaldehyde 8. Chlorpheniramine. Diflunisal 9. Phenol 6. Hexanophenone red-acids blue-bases white-neutrals Comparative separations may not be representative of all applications. Columns are ph stable from.- under isocratic conditions. Columns are ph stable.-8. under gradient conditions. Phenomenex l WEB: 7

8 A New Era of Technical Support Services, Let Us Do the Work for You PhenoLogix, our in-house application support lab, saves you time and money by screening multiple scout columns and solvent strategies for new purification methods or revalidating your current methods. We work together to make you successful by minimizing your process purification development time and optimizing your purification method. Column Screening Normal Phase Reversed Phase Polar Organic SFC Chiral Method Optimization Services Fast Turnaround Easy Method Transfer Continued Support Preparative and Process Scale-Up Media Screening Small Scale Purification DAC Packing Assistance Get started today and let us exceed your expectations. 8

9 Extend the Lifetime of Your Axia Preparative Column Use the SecurityGuard PREP column protection system! Extend preparative column lifetime by as much as x Protect column from samples that precipitate out of solution Protect column from contaminants Stable and leak-free up to 6 ml/min The SecurityGuard PREP system was designed to effectively (and inexpensively) protect your valuable Prep columns from the damaging effects of mobile phase and sample chemical contaminants and particulates, without altering your chromatographic results. Forced Degradation Lifetime Study Axia packed column with SecurityGuard PREP cartridge after initial injection Injection - 4 min Conditions Column: Luna µm C8() Axia Packed Dimension: x. mm Part No.: B-4-P-AX Mobile Phase: A:.% TFA in Water B:.% TFA in Water/Acetonitrile (:7) Gradient: Linear 9:7 (A/B) to % B over minutes Injection Volume: 4 µl Flow Rate: 6 ml/min Temperature: Ambient Detection: 7 nm Sample:. Nadolol. Metoprolol. Propranolol Axia packed column with SecurityGuard PREP cartridge after multiple injections Injection 4-4 min Time to change the PREP cartridge Axia packed column after removing SecurityGuard column protection system Injection 4 Original column performance maintained by using SecurityGuard PREP SecurityGuard PREP - 4 min 9

10 If Axia packed columns do not provide at least an equivalent separation as compared to a competing preparative column of the same particle size, same phase and dimensions, return the column with comparative data within 4 days for a FULL REFUND. Only applies to. mm ID columns.

11 Ordering Information Kinetex Analytical Columns SecurityGuard SecurityGuard µm Columns (mm) ULTRA Cartridges* ULTRA Cartridges* x. /pk x 4.6 x 4.6 x 4.6 x 4.6 /pk XB-C8 B-46-AN AJ-878 B-46-E D-46-E F-46-E G-46-E AJ-8768 C8 B-46-AN AJ-878 B-46-E D-46-E F-46-E G-46-E AJ-8768 PFP B-46-AN AJ-8787 B-46-E D-46-E F-46-E G-46-E AJ-877 Phenyl-Hexyl B-46-AN AJ-8788 B-46-E D-46-E F-46-E G-46-E AJ-8774 for. mm ID for 4.6 mm ID SecurityGuard.6 μm Analytical Columns (mm) ULTRA Cartridges* x 4.6 x x 4.6 x 4.6 x 4.6 /pk XB-C8 B-4496-E C-4496-E D-4496-E F-4496-E AJ-8768 C8 A-446-E B-446-E C-446-E D-446-E F-446-E AJ-8768 PFP A-4477-E B-4477-E C-4477-E D-4477-E F-4477-E AJ-877 Phenyl-Hexyl B-449-E C-449-E D-449-E F-449-E AJ-8774 for 4.6 mm ID SecurityGuard.6 μm MidBore Columns (mm) ULTRA Cartridges* x. x. 7 x. x. x. /pk XB-C8 A-4496-Y B-4496-Y C-4496-Y D-4496-Y F-4496-Y AJ-877 C8 A-446-Y B-446-Y C-446-Y D-446-Y F-446-Y AJ-877 PFP A-4477-Y B-4477-Y C-4477-Y D-4477-Y F-4477-Y AJ-878 Phenyl-Hexyl D-449-Y F-449-Y AJ-878 for. mm ID SecurityGuard.6 μm Minibore Columns (mm) ULTRA Cartridges* x. x. 7 x. x. x. /pk XB-C8 A-4496-AN B-4496-AN C-4496-AN D-4496-AN F-4496-AN AJ-878 C8 A-446-AN B-446-AN C-446-AN D-446-AN F-446-AN AJ-878 PFP A-4477-AN B-4477-AN C-4477-AN D-4477-AN F-4477-AN AJ-8787 Phenyl-Hexyl A-449-AN B-449-AN C-449-AN D-449-AN F-449-AN AJ-8788 for. mm ID SecurityGuard.7 μm MidBore Columns (mm) ULTRA Cartridges* x. x. x. /pk XB-C8 A-4498-Y B-4498-Y D-4498-Y AJ-877 C8 B-447-Y D-447-Y AJ-877 PFP B-4476-Y D-4476-Y AJ-878 for. mm ID SecurityGuard.7 μm Minibore Columns (mm) ULTRA Cartridges* x. x. x. x. /pk. µm Columns (mm) x. XB-C8 A-4498-AN B-4498-AN D-4498-AN F-4498-AN AJ-878 C8 A-447-AN B-447-AN D-447-AN F-447-AN AJ-878 PFP A-4476-AN B-4476-AN D-4476-AN F-4476-AN AJ-8787 Phenyl-Hexyl B-4-AN D-4-AN F-4-AN AJ-8788 for. mm ID C8 B-4-AN Axia Packed Kinetex Preparative Columns SecurityGuard µm Axia Packed Preparative Columns (mm) PREP Cartridges** x. x. x. x. x. /ea XB-C8 B-46-P-AX D-46-P-AX F-46-P-AX G-46-P-AX AJ-94 C8 B-46-P-AX D-46-P-AX F-46-P-AX G-46-P-AX AJ-94 PFP B-46-P-AX D-46-P-AX F-46-P-AX G-46-P-AX AJ-946 Phenyl-Hexyl B-46-P-AX D-46-P-AX F-46-P-AX G-46-P-AX AJ-947 for. mm ID SecurityGuard Column Protection Protect your Kinetex and Axia Packed preparative columns from the damaging effects of mobile phase and sample chemical contaminants with SecurityGuard ULTRA and SecurityGuard PREP Dramatically extends column lifetime and performance Virtually no change in chromatography Simple to use *SecurityGuard ULTRA cartridges require holder, Part No. AJ-9 **SecurityGuard PREP cartridges require holder, Part No. AJ-8 SecurityGuard ULTRA Part No. Description Unit Price AJ-9 SecurityGuard ULTRA Holder for UHPLC/ HPLC Columns. to 4.6mm ID ea SecurityGuard PREP Part No. Description Unit Price AJ-8 SecurityGuard PREP HPLC Guard Cartridge Holder Kit,.mm ID, includes column coupler ea Phenomenex l WEB:

12 Preparative Chromatography Meets UHPLC Australia t: f: Austria t: -9- f: -9- Belgium t: 4 (French) t: 8666 (Dutch) f: + ()-8749 beinfo@phenomenex.com Canada t: (8) 4-68 f: () info@phenomenex.com Denmark t: f: nordicinfo@phenomenex.com Finland t: f: nordicinfo@phenomenex.com France t: 9 f: 9 franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: 4-4 f: 4-4 indiainfo@phenomenex.com Ireland t: 47 4 f: eireinfo@phenomenex.com Italy t: 67 f: 67 italiainfo@phenomenex.com Luxembourg t: + ()-487 f: + ()-8749 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: -487 f: nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: 8 f: nordicinfo@phenomenex.com Puerto Rico t: (8) 4-HPLC f: () info@phenomenex.com Sweden t: f: nordicinfo@phenomenex.com United Kingdom t: 6-67 f: ukinfo@phenomenex.com United States t: () - f: () info@phenomenex.com All other countries: Corporate Office USA t: () - f: () info@phenomenex.com BR94_W Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Phenomenex, Gemini, Kinetex, and Luna are registered trademarks, Axia, MidBore, Synergi, and SecurityGuard are trademarks of Phenomenex. Waters is a registered trademark, XBridge and OBD are trademarks of Waters Corporation. Disclaimer Phenomenex is not affiliated with Waters Corporation. Comparative separations may not be representative of all applications. Axia is patented by Phenomenex. U.S. Patent No. 7,674,8 Phenomenex. All rights reserved.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

HPLC. Varian Dynamax Preparative HPLC Columns

HPLC. Varian Dynamax Preparative HPLC Columns HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

Vitamin Testing APPLICATIONS GUIDE

Vitamin Testing APPLICATIONS GUIDE Vitamin Testing APPLICATIONS GUIDE Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Effective Surface Area (m 2 /g) Pore Size (Å)

Effective Surface Area (m 2 /g) Pore Size (Å) n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

2012 Waters Corporation 1

2012 Waters Corporation 1 An Introduction to Waters HPLC and ACQUITY UPLC Column Technologies for small molecule analysis Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 5659 6288 Fax: +358-9-5659 5659 6282 Waters Finland

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2. Five Distinct Polysaccharide Phases to Resolve 9 % of Your Enantiomers* If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 % SIMPLIFIED IRAL SEPARATIS FIVE omplementary hiral Phases for Greater Selectivity Resolve 9 % of all your Enantiomers using Screening Kits * FREE hiral Screening and Separation Services. *Based on screening

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Separations. Sweet Sugar. Are in Your Future. New.   Luna Omega SUGAR LC Column OMEGA OMEGA Sweet Sugar Separations Are in Your Future New Luna Omega SUGAR LC Column Improved carbohydrate retention and separation with novel HILIC selectivity Enhanced lifetime with highly robust and efficient

More information

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles

More information

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE APPLICATINS Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE Sky Countryman, Shahana Huq, Terrell Mathews, et al. Phenomenex,

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

An Easier QuEChERS Solution for Diverse Matrices. Learn more at An Easier QuEChERS Solution for Diverse Matrices Learn more at www.phenomenex.com/roq What is roq QuEChERS? QuEChERS is a descriptive acronym that stands for Quick, Easy, Cheap, Effective, Rugged, and

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

World Renowned HPLC Media Reinvented for UHPLC!

World Renowned HPLC Media Reinvented for UHPLC! OMEGA World Renowned HPLC Media Reinvented for UHPLC! New. µm Staggering UHPLC Efficiencies and Performance Extreme Ruggedness and Mechanical Strength Perfect Complement to Kinetex Core-Shell Technology

More information

TN-0116 Scott Krepich

TN-0116 Scott Krepich TN-116 APPLICATIONS Analysis of Perfluorinated Compounds (PFCs) in Aqueous Matrices, Evaluating Various Online SPE Sorbents by LC-MS/MS Scott Krepich Senior Field Application Scientist Scott enjoys surfing

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

Kromasil The way to peak performance in liquid chromatography

Kromasil The way to peak performance in liquid chromatography Kromasil The way to peak performance in liquid chromatography Kromasil product catalogue Kromasil is offered in a wide assortment of columns and in bulk amounts from parts of kilograms to metric tons.

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis Zhenyu Wang Merck Research Laboratories NJCG 2013 Outline SFC chronicle The journey of a half century Re-birth

More information

Thermo Scientific Hypersil BDS Columns

Thermo Scientific Hypersil BDS Columns Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific Thermo Scientific Hypersil BDS

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

CANNABIS TESTING. LC/GC/SFC/SPE/QuEChERS. Analytical Options For Your Laboratory Needs.

CANNABIS TESTING. LC/GC/SFC/SPE/QuEChERS. Analytical Options For Your Laboratory Needs. CANNABIS TESTING LC/GC/SFC/SPE/QuEChERS Analytical ptions For Your Laboratory Needs www.phenomenex.com/cannabis If products in this guide do not provide at least an equivalent separation as compared to

More information

Purification - Flash Chromatography

Purification - Flash Chromatography SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver

More information

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania

More information

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design Alan P McKeown amckeown@ace-hplc.com Advanced Chromatography Technologies www.ace-hplc.com www.mac-mod.com Outline 2 Chromatographic

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information