1 Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems

2 Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein and Peptide Separations Core-shell particle technology provides striking increases in peak capacity and resolution at lower backpressures, giving chromatographers the ability to achieve ultra-high performance on ANY system, HPLC or UHPLC. Optimizing the pore size and shell thickness for intact proteins or smaller peptide fragments provides well-defined depth penetration of biomolecules leading to maximum separation power. 3.6 µm Core-Shell Particle 2.6 µm Solid Core.5 µm Porous Shell 1.7 µm Core-Shell Particle 1.25 µm Solid Core.22 µm Porous Shell Aeris Peptide 3.6 µm 1.7 µm Aeris WIDEPORE 3.2 µm Solid Core 3.6 µm Core-Shell Particle.2 µm Porous Shell 3.6 µm Aeris TM WIDEPORE and make a perfect pair for peptide mapping. HPLC SYSTEM solid core solid core solid core 3.6 µm PROTEIN OR PEPTIDE < 1 kda UHPLC SYSTEM 1.7 µm 3.6 µm Hydrophilic Proteins 3.6 µm > 1 kda HPLC OR UHPLC SYSTEMS Hydrophobic Proteins 3.6 µm XB-C8 Very Hydrophobic Proteins 3.6 µm 213 Phenomenex, Inc. All rights reserved.

3 Aeris Peptide Ultra-High Resolving Power on HPLC and UHPLC Systems with 3.6 µm Columns The Aeris PEPTIDE 3.6 µm core-shell column was designed with one purpose in d: to maximize the separation of large numbers of peptides on any HPLC or UHPLC system. Because core-shell particles remove the backpressure constraints of HPLC or UHPLC systems, chromatographers can achieve the ultra-high performance of similar length sub-2 µm columns at a fraction of the backpressure µm 125 bar Resolves an Additional Pair of Peptides 8 *Waters ACQUITY BEH 1.7 µm C bar Conditions for both columns: Column: 3.6 µm ACQUITY BEH 1.7 µm C18 Dimensions: 15 x 2.1 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (97:3) for 5 to A/B (55:45) over 55 Flow Rate:.3 ml/ Temperature: 4 ºC Instrument: Agilent 12SL Detection: 214 nm (ambient) Sample: Human IgG Tryptic Digest App ID App ID Maximize Performance on UHPLC Systems with 1.7 µm Technology AU With pressure stability up to 1, bar and the high efficiencies brought about by core-shell particle technology, the sub-2 µm column produces breakthrough chromatographic performance on UHPLC systems. Use 1.7 µm columns to boost the performance of sub-2 µm fully porous peptide mapping methods. 1.7 µm AU *Waters ACQUITY BEH 1.7 µm C18 Conditions for both columns: Column: 1.7 µm ACQUITY BEH 1.7 µm C18 Dimensions: 15 x 2.1 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.8 % TFA Gradient: A/B (97:3) for 1.5 to A/B (6:4) over 11 to A/B (5:95) over 1 Flow Rate:.5 ml/ Temperature: 4 ºC Injection Volume: 5 µl Instrument: Aglient 12SL Detection: 214 nm (ambient) Sample: Alpha-Casein Tryptic Digest.3.3 Identify More Peaks Peak count = 79 Peak count = App ID App ID * Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Study was performed using new columns and, to the extent possible, identical experimental conditions were applied. Comparative separations may not be representative of all applications.

4 Aeris Widepore Utilize Long Columns to Maximize Resolution on HPLC and UHPLC Systems Aeris WIDEPORE 3.6 µm Increased Resolution Using Core-Shell Technology *Waters ACQUITY BEH3 1.7 µm C18 12 bar 4 bar App ID App ID x 2.1 mm 15 x 2.1 mm Moving to a Longer Column 25 x 2.1 mm 3.6 µm 16 bar Even Greater Resolution on Your UHPLC System App ID Conditions for all columns: Column: 3.6 µm ACQUITY BEH3 1.7 µm C18 Dimensions: as noted in chromatogram Mobile Phase: A: Water with.1 % TFA B: Acetonitrile Gradient: A/B (9:1) for 5 to A/B (5:5) over 45 Flow Rate:.2 ml/ Temperature: 22 ºC Injection Volume: 2 µl Instrument: Agilent 12SL Detection: 21 nm Sample: Degraded Myoglobin Easy Method Development with Three Selectivities 3.6 µm Core-Shell Stationary Si Si XB- C18 XB- C8 Maximum hydrophobicity recommended for: Proteins Hydrophilic proteins PEGylated proteins High temperature separations Alternative selectivity for peptide mapping XB-C8 Moderate hydrophobicity recommended for: Large proteins Moderately hydrophobic proteins Monoclonal antibodies Glycosylated proteins High temperature separations Low hydrophobicity recommended for: Very large proteins Very hydrophobic proteins Membrane proteins Least retentive * Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Study was performed using new columns and, to the extent possible, identical experimental conditions were applied. Comparative separations may not be representative of all applications.

5 Ordering Information Material Characteristics Packing Material Total Particle Porous Size (µm) Shell (µm) Core Size (µm) Pore Size (Å) ph Stability Temp Stability Pressure Stability C 6 bar C bar Order Online for Exclusive Savings! C 6 bar 5 x 2.1 x x x 2.1 B-4482-AN D-4482-AN F-4482-AN G-4482-AN AJ-8783 XB-C8 B-4481-AN D-4481-AN F-4481-AN G-4481-AN AJ-8785 B-4486-AN D-4486-AN F-4486-AN G-4486-AN AJ µm Minibore Columns (mm) x x x 4.6 D-4482-E F-4482-E G-4482-E AJ µm Analytical Columns (mm) UHPLC Column Protection Cartridge Holder Cartridge with Holder XB-C8 D-4481-E F-4481-E G-4481-E AJ-8771 D-4486-E F-4486-E G-4486-E AJ x 2.1 x x 2.1 B-456-AN D-456-AN F-456-AN AJ µm Minibore Columns (mm) 5 x 2.1 x x x 2.1 B-457-AN D-457-AN F-457-AN G-457-AN AJ µm Minibore Columns (mm) x x x 4.6 D-457-E F-457-E G-457-E AJ-8946 ea AJ-9 Price 3.6 µm Analytical Columns (mm) If you are not completely satisfied with your Aeris core-shell columns, return the column with comparative data within 45 days for a FULL REFUND. ULTRA Cartridge Holder* (for 2.1 to 4.6 mm ID columns) ULTRA Guard Cartridge Holder * ULTRA cartridges require holder part number AJO-9.

6 Core-Shell Technology for Proteins and Peptides Australia t: f: au Austria t: f: Belgium t: (French) t: (Dutch) f: +31 () be Canada t: (8) f: (31) Denmark t: f: nordic Finland t: f: nordic France t: f: france Germany t: f: anfrage@phenomenex.com India t: f: india Ireland t: f: eire Italy t: f: italia Luxembourg t: +31 () f: +31 () nl Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nl New Zealand t: f: nz Norway t: f: nordic Puerto Rico t: (8) 541-HPLC f: (31) Sweden t: f: nordic United Kingdom t: f: uk United States t: (31) f: (31) All other countries: Corporate Office USA t: (31) f: (31) FL _W Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at Trademarks Aeris and are trademarks of Phenomenex. Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. Disclaimer Phenomenex is not affiliated with Agilent Technologies, Inc. or Waters Corporation. Comparative separations may not be representative of all applications. 213 Phenomenex, Inc. All rights reserved.

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

GlycanPac AXR-1 Columns

GlycanPac AXR-1 Columns CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

Fused-Core Particles:

Fused-Core Particles: Fused-Core Particles: Varying Shell Thickness and Pore Size Stephanie A. Schuster; Joseph J. Kirkland; Brian M. Wagner; Barry E. Boyes; William L. Johnson; Timothy J. Langlois; Joseph J. DeStefano Advanced

More information

The Raptor HILIC-Si Column

The Raptor HILIC-Si Column The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution

More information

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT. Objective The aim of the study presented is to determine the presence of target Gingkolides in Gingko biloba leaf extract. The data presented shows Gingkolides determined to be present in the extract analyzed.

More information

Improving Food Process Control Using the

Improving Food Process Control Using the Improving Food Process Control Using the UPLC Amino Acid Analysis Solution Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION Food products have different desirability and value based in

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher

More information

Pharmacopoeia Methods

Pharmacopoeia Methods Allowable Adjustments to Pharmacopoeia Methods Isocratic Separations Component European Pharmacopoeia (Ph. Eur.) Composition of the mobile phase ± 30 % Relative or ± 2 % absolute, whichever is the larger;

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

Studies on Stationary Phase Selectivity for Solid-Core Particles

Studies on Stationary Phase Selectivity for Solid-Core Particles Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and

More information

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 % SIMPLIFIED IRAL SEPARATIS FIVE omplementary hiral Phases for Greater Selectivity Resolve 9 % of all your Enantiomers using Screening Kits * FREE hiral Screening and Separation Services. *Based on screening

More information

Effective Surface Area (m 2 /g) Pore Size (Å)

Effective Surface Area (m 2 /g) Pore Size (Å) n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing

More information

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

New HPLC Column Options for UHPLC

New HPLC Column Options for UHPLC New HPLC Column Options for UHPLC Rapid Resolution High Definition Columns and More Chor Koon Tan, PhD Business Development Manager Columns & Supplies Division Asia-Pacific Agilent Technologies Page 1

More information

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information

InertSustainBio C18. Rapid Separations of Proteins and Peptides

InertSustainBio C18. Rapid Separations of Proteins and Peptides InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC Mia Summers and Kenneth J. Fountain Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Updating USP Methods from HPLC to UPLC using sub-2 µm columns 85% decrease in analysis time, faster throughput

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 129 Infinity LC System Application Note Pharmaceutical and Chemical Analysis

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED

More information

PyroMark Q24 CpG MGMT Handbook

PyroMark Q24 CpG MGMT Handbook December 2009 PyroMark Q24 CpG MGMT Handbook For quantification of CpG methylation in region +17 to +39 in the MGMT gene Sample & Assay Technologies QIAGEN Sample and Assay Technologies QIAGEN is the leading

More information

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA An Ultra High Resolution Glycan Column for Isomeric Separation and the Structural Identification of Labeled N-Glycans from Proteins Including Antibodies Udayanath Aich, 1 Julian Saba, 2 Rosa Viner, 2 Shanhua

More information