Core-Shell Technology for Proteins and Peptides
|
|
- Aubrey Allison
- 6 years ago
- Views:
Transcription
1 Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems
2 Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein and Peptide Separations Core-shell particle technology provides striking increases in peak capacity and resolution at lower backpressures, giving chromatographers the ability to achieve ultra-high performance on ANY system, HPLC or UHPLC. Optimizing the pore size and shell thickness for intact proteins or smaller peptide fragments provides well-defined depth penetration of biomolecules leading to maximum separation power. 3.6 µm Core-Shell Particle 2.6 µm Solid Core.5 µm Porous Shell 1.7 µm Core-Shell Particle 1.25 µm Solid Core.22 µm Porous Shell Aeris Peptide 3.6 µm 1.7 µm Aeris WIDEPORE 3.2 µm Solid Core 3.6 µm Core-Shell Particle.2 µm Porous Shell 3.6 µm Aeris TM WIDEPORE and make a perfect pair for peptide mapping. HPLC SYSTEM solid core solid core solid core 3.6 µm PROTEIN OR PEPTIDE < 1 kda UHPLC SYSTEM 1.7 µm 3.6 µm Hydrophilic Proteins 3.6 µm > 1 kda HPLC OR UHPLC SYSTEMS Hydrophobic Proteins 3.6 µm XB-C8 Very Hydrophobic Proteins 3.6 µm 213 Phenomenex, Inc. All rights reserved.
3 Aeris Peptide Ultra-High Resolving Power on HPLC and UHPLC Systems with 3.6 µm Columns The Aeris PEPTIDE 3.6 µm core-shell column was designed with one purpose in d: to maximize the separation of large numbers of peptides on any HPLC or UHPLC system. Because core-shell particles remove the backpressure constraints of HPLC or UHPLC systems, chromatographers can achieve the ultra-high performance of similar length sub-2 µm columns at a fraction of the backpressure µm 125 bar Resolves an Additional Pair of Peptides 8 *Waters ACQUITY BEH 1.7 µm C bar Conditions for both columns: Column: 3.6 µm ACQUITY BEH 1.7 µm C18 Dimensions: 15 x 2.1 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (97:3) for 5 to A/B (55:45) over 55 Flow Rate:.3 ml/ Temperature: 4 ºC Instrument: Agilent 12SL Detection: 214 nm (ambient) Sample: Human IgG Tryptic Digest App ID App ID Maximize Performance on UHPLC Systems with 1.7 µm Technology AU With pressure stability up to 1, bar and the high efficiencies brought about by core-shell particle technology, the sub-2 µm column produces breakthrough chromatographic performance on UHPLC systems. Use 1.7 µm columns to boost the performance of sub-2 µm fully porous peptide mapping methods. 1.7 µm AU *Waters ACQUITY BEH 1.7 µm C18 Conditions for both columns: Column: 1.7 µm ACQUITY BEH 1.7 µm C18 Dimensions: 15 x 2.1 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.8 % TFA Gradient: A/B (97:3) for 1.5 to A/B (6:4) over 11 to A/B (5:95) over 1 Flow Rate:.5 ml/ Temperature: 4 ºC Injection Volume: 5 µl Instrument: Aglient 12SL Detection: 214 nm (ambient) Sample: Alpha-Casein Tryptic Digest.3.3 Identify More Peaks Peak count = 79 Peak count = App ID App ID * Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Study was performed using new columns and, to the extent possible, identical experimental conditions were applied. Comparative separations may not be representative of all applications.
4 Aeris Widepore Utilize Long Columns to Maximize Resolution on HPLC and UHPLC Systems Aeris WIDEPORE 3.6 µm Increased Resolution Using Core-Shell Technology *Waters ACQUITY BEH3 1.7 µm C18 12 bar 4 bar App ID App ID x 2.1 mm 15 x 2.1 mm Moving to a Longer Column 25 x 2.1 mm 3.6 µm 16 bar Even Greater Resolution on Your UHPLC System App ID Conditions for all columns: Column: 3.6 µm ACQUITY BEH3 1.7 µm C18 Dimensions: as noted in chromatogram Mobile Phase: A: Water with.1 % TFA B: Acetonitrile Gradient: A/B (9:1) for 5 to A/B (5:5) over 45 Flow Rate:.2 ml/ Temperature: 22 ºC Injection Volume: 2 µl Instrument: Agilent 12SL Detection: 21 nm Sample: Degraded Myoglobin Easy Method Development with Three Selectivities 3.6 µm Core-Shell Stationary Si Si XB- C18 XB- C8 Maximum hydrophobicity recommended for: Proteins Hydrophilic proteins PEGylated proteins High temperature separations Alternative selectivity for peptide mapping XB-C8 Moderate hydrophobicity recommended for: Large proteins Moderately hydrophobic proteins Monoclonal antibodies Glycosylated proteins High temperature separations Low hydrophobicity recommended for: Very large proteins Very hydrophobic proteins Membrane proteins Least retentive * Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Study was performed using new columns and, to the extent possible, identical experimental conditions were applied. Comparative separations may not be representative of all applications.
5 Ordering Information Material Characteristics Packing Material Total Particle Porous Size (µm) Shell (µm) Core Size (µm) Pore Size (Å) ph Stability Temp Stability Pressure Stability C 6 bar C bar Order Online for Exclusive Savings! C 6 bar 5 x 2.1 x x x 2.1 B-4482-AN D-4482-AN F-4482-AN G-4482-AN AJ-8783 XB-C8 B-4481-AN D-4481-AN F-4481-AN G-4481-AN AJ-8785 B-4486-AN D-4486-AN F-4486-AN G-4486-AN AJ µm Minibore Columns (mm) x x x 4.6 D-4482-E F-4482-E G-4482-E AJ µm Analytical Columns (mm) UHPLC Column Protection Cartridge Holder Cartridge with Holder XB-C8 D-4481-E F-4481-E G-4481-E AJ-8771 D-4486-E F-4486-E G-4486-E AJ x 2.1 x x 2.1 B-456-AN D-456-AN F-456-AN AJ µm Minibore Columns (mm) 5 x 2.1 x x x 2.1 B-457-AN D-457-AN F-457-AN G-457-AN AJ µm Minibore Columns (mm) x x x 4.6 D-457-E F-457-E G-457-E AJ-8946 ea AJ-9 Price 3.6 µm Analytical Columns (mm) If you are not completely satisfied with your Aeris core-shell columns, return the column with comparative data within 45 days for a FULL REFUND. ULTRA Cartridge Holder* (for 2.1 to 4.6 mm ID columns) ULTRA Guard Cartridge Holder * ULTRA cartridges require holder part number AJO-9.
6 Core-Shell Technology for Proteins and Peptides Australia t: f: au Austria t: f: Belgium t: (French) t: (Dutch) f: +31 () be Canada t: (8) f: (31) Denmark t: f: nordic Finland t: f: nordic France t: f: france Germany t: f: anfrage@phenomenex.com India t: f: india Ireland t: f: eire Italy t: f: italia Luxembourg t: +31 () f: +31 () nl Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nl New Zealand t: f: nz Norway t: f: nordic Puerto Rico t: (8) 541-HPLC f: (31) Sweden t: f: nordic United Kingdom t: f: uk United States t: (31) f: (31) All other countries: Corporate Office USA t: (31) f: (31) FL _W Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at Trademarks Aeris and are trademarks of Phenomenex. Waters and ACQUITY are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. Disclaimer Phenomenex is not affiliated with Agilent Technologies, Inc. or Waters Corporation. Comparative separations may not be representative of all applications. 213 Phenomenex, Inc. All rights reserved.
APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns
Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE
More informationAeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE
Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance
More informationAPPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit
Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,
More informationAPPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1
APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there
More informationFor Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.
For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies
More informationAPPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.
Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually
More informationAPPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology
Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm
More informationColumns The FIRST and ONLY sub-2 µm core-shell columns on the market
Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad
More informationPreparative Chromatography Meets UHPLC
Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award
More informationA Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns
A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,
More informationAPPLICATIONS TN Analytical Method
APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell
More informationProtect Your Mass Spec
Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of
More informationLabs Across the World Are Advancing Their Protein Precipitation
Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance
More informationAPPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD
Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside
More informationAPPLICATIONS TN Materials and Methods
APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with
More informationEnantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases
T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,
More informationYes You Can! New! Amazing EVO C18. Core-Shell Technology
Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used
More informationNEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!
Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell
More informationFinally, a Solid Phase Extraction product for Drugs of Abuse
n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent
More informationRun 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.
APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,
More informationSIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced
SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector
More informationThe high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.
The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance
More informationPhospholipid Removal Solutions
Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause
More informationFigure 1. Core-Shell Particle Technology
Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future
More informationAwesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology
Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally
More informationCore-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns
Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the
More informationAPPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column
Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,
More informationUltimate Core Performance to Maximize Your Investment
Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience
More informationRapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite
T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko
More informationAPPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)
APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her
More informationMETHAMPHETAMINE & AMPHETAMINE
METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS
More informationCANNABIS TESTING ACCESSORIES
CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe
More informationPAIN PANEL. Research and Solutions
PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug
More informationExceed your Purification Goals. Guaranteed. Phenomenex l WEB:
Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability
More informationAPPLICATION TN Materials and Methods Reagents and Chemicals
TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also
More informationA New Era in SFC Column Technology
B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationA New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis
A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and
More informationA Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS
A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these
More informationC30 ISOMERS HAVE MET THEIR MATCH
C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES
More informationLC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined
ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationPhenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,
More informationGlycanPac AXR-1 Columns
CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous
More informationKeep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse
Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons
More informationComparison of a UPLC Method across Multiple UHPLC Systems
Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid
More informationHyper-fast & Super-rugged
Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle
More informationCOMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput
ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting
More informationFused-Core Particles:
Fused-Core Particles: Varying Shell Thickness and Pore Size Stephanie A. Schuster; Joseph J. Kirkland; Brian M. Wagner; Barry E. Boyes; William L. Johnson; Timothy J. Langlois; Joseph J. DeStefano Advanced
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.
Objective The aim of the study presented is to determine the presence of target Gingkolides in Gingko biloba leaf extract. The data presented shows Gingkolides determined to be present in the extract analyzed.
More informationImproving Food Process Control Using the
Improving Food Process Control Using the UPLC Amino Acid Analysis Solution Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION Food products have different desirability and value based in
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationNEW Kinetex F5. HPLC/UHPLC Core-Shell Columns
Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious
More informationKeep it Clean with Strata -X
Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10
More informationBioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS
Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher
More informationPharmacopoeia Methods
Allowable Adjustments to Pharmacopoeia Methods Isocratic Separations Component European Pharmacopoeia (Ph. Eur.) Composition of the mobile phase ± 30 % Relative or ± 2 % absolute, whichever is the larger;
More informationSepax Technologies, Inc.
Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid
More informationImpurity Profiling of Carbamazepine by HPLC/UV
Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis
More informationPAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes
Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of
More informationRoc On with These Dependable LC Columns
Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you
More informationSeparation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column
Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based
More informationStudies on Stationary Phase Selectivity for Solid-Core Particles
Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com
More informationMaximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns
Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors
More informationAnalytical and Preparative SFC Columns
Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationSIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %
SIMPLIFIED IRAL SEPARATIS FIVE omplementary hiral Phases for Greater Selectivity Resolve 9 % of all your Enantiomers using Screening Kits * FREE hiral Screening and Separation Services. *Based on screening
More informationEffective Surface Area (m 2 /g) Pore Size (Å)
n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing
More informationProviding a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis
Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation
More informationNew Luna Omega. Columns. The Final Word in Fully Porous UHPLC
New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC
More informationNew HPLC Column Options for UHPLC
New HPLC Column Options for UHPLC Rapid Resolution High Definition Columns and More Chor Koon Tan, PhD Business Development Manager Columns & Supplies Division Asia-Pacific Agilent Technologies Page 1
More informationApplication Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix
Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes
More informationCore-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology
Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products
More informationPrep Columns. and Bulk Media. and Bulk Media
Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36
More informationSeparation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns
Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives
More informationEffective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate
Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,
More informationExtended Application Note
Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and
More informationHigh-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine
High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationAnalytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP
Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract
More informationInertSustainBio C18. Rapid Separations of Proteins and Peptides
InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight
More informationACE Excel UHPLC Columns
Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationUltra Columns. also available. ordering note
: 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak
More informationUSP Method Transfer of Ziprasidone HCl from HPLC to UPLC
Mia Summers and Kenneth J. Fountain Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Updating USP Methods from HPLC to UPLC using sub-2 µm columns 85% decrease in analysis time, faster throughput
More informationUltra Columns HPLC COLUMNS
Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501
More informationSecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!
U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative
More informationIncreasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System
Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 129 Infinity LC System Application Note Pharmaceutical and Chemical Analysis
More informationThermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific
Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N
More informationProbing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION
Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is
More informationRestek Ultra II HPLC Columns
Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra
More informationChromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns
: 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar
More informationChoosing Preparative Columns
Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical
More informationYMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability
YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.
More informationHigh-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine
High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,
More informationConfidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis
A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED
More informationPyroMark Q24 CpG MGMT Handbook
December 2009 PyroMark Q24 CpG MGMT Handbook For quantification of CpG methylation in region +17 to +39 in the MGMT gene Sample & Assay Technologies QIAGEN Sample and Assay Technologies QIAGEN is the leading
More informationThermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA
An Ultra High Resolution Glycan Column for Isomeric Separation and the Structural Identification of Labeled N-Glycans from Proteins Including Antibodies Udayanath Aich, 1 Julian Saba, 2 Rosa Viner, 2 Shanhua
More information