1 LC/MS Crossroads Jerry Pappas Sales Representative 265 Davidson Avenue Somerset, NJ
2 Comparison of Quads and Traps Ion Traps Quadrupoles Mass Separation in time Mass Separation in space High sensitivity Full Scan Lower sensitivity Full Scan Lower sensitivity SIM and SRM Offer multiple stages of MS n High sensitivity SIM and SRM Offers Only MS or MS/MS Parent and neutral loss scans 2
3 LCQ Instrumentation Classic Duo Deca 3
4 Duo/Deca Comparisons LCQ DUO 400um capillary 2 octopoles One rotary pump LCQ DECA 500um capillary 1 square quadrupole & 1 octopole 2 rotary pumps Deca: approximately 10 x better signal than Duo 4
5 5 Current LCQ Generation
6 Advantage/XP Comparisons 450um Ion Transfer Tube Orthogonal Probes 550um Ion Transfer Tube Orthogonal Probes XP: approximately 10 x better signal than Advantage 6
7 LCQ MS n Quadrupole Ion Trap LC Pump ESI Quadrupole Ion Trap Ion optics Detector Syringe Pump Quadrupole refers to the shape of the ion confining field inside the trap and not the shape of or number of electrodes in the trap. 7
8 Mass Spectrometry Simplified G M S D enerate ove elect etect Ion production Ion optics Mass filter Electron multiplier 8
9 The Mass Spectrum Light, all colors Prism Red Green Blue Ions, various masses Mass Spectrometer
10 Trace produced by summing all observed masses in each scan Total Ion Chromatogram or TIC 10
11 Ionization vs. Fragmentation API CI EI Soft Ionization Hard No Fragments Fragments 11
12 EI and CI Mass Spectra of Ephedrine 100 EI 58 % Relative Intensity CI 148 (MH) 166 MW = 165Th m/z 12
13 Ionization Techniques 200,000 ESI 15,000 1,000 APCI Molecular Weight GC PBI TSP FAB Non Polar Polar 13
14 What is API? Atmospheric Pressure Ionization Source Types: 1. Electrospray Ionisation (ES) Solution phase process (for the most part). 2. APCI (Atmospheric Pressure Chemical Ionization) - Gasphase process. Source Purpose: 1. Ionize the analyte (APCI) or transport ion in solution to the gas phase. 2. Desolvate sample flow for introduction into mass spectrometer. 3. Baffle the first vacuum region of the MS from atmospheric pressure in the source. 4. Pump away neutrals and opposite charged ions which would otherwise interfere with the analysis of the desired polarity. 14
15 LCQ Classic/Duo/Deca API Probes Electrospray Ionization (ESI) Peek insulator Atmospheric Pressure Chemical Interface (APCI) 15
16 LCQ Advantage/XP API Probes Electrospray Ionization (ESI) Atmospheric Pressure Chemical Interface (APCI) Orthogonal ESI & APCI probes 16
17 Chemistry Considerations ESI: Ions formed by solution chemistry Good for Thermally labile analytes Good for Polar analytes Good for Large Molecules (Proteins / Peptides) APCI: Ions formed by gas phase chemistry Good for Volatile / Thermally Stable Good for Non-polar analytes Good for Small Molecules (Steroids) 17
18 ESI Versatility Advantage/XP (Right: Picture represents a low flow position, <50uL/min) A-F Positions for increased ruggedness 1-5 Positions (Left: Picture represents a high flow position) 18
19 Electrospray Basic Layout Heated Capillary ESI Needle /- 5 kv Solvent evaporation and ion release Taylor Cone 19
20 APCI Position on Advantage/XP In/Out Movable Corona Discharge Pin Total control for any flow rate (200ul/min ul/min) 20
21 LC Flow Rates ESI: APCI: 3 µl/min - 1mL/minute Optimal Flow Rate: 200 µl/min Generally, higher flow rates require higher heated capillary temperatures and higher gas flow rates. 200 µl/min - 2mL/minute. Optimal Flow Rate: 500 µl/min Generally, higher flow rates require more sheath and auxiliary gas, but do not require higher heated capillary temperatures. 21
22 Theoretical Increase in Response Conc max = D 2 Column 1 D 2 Column 2 Col. Diameter mm Flow Rate ml/min < 10 µl / min Theoretical Increase Capillary
23 Acids Bases LC Additives Do not use inorganic acids (may cause source corrosion) Formic and acetic acid are recommended Do not use alkali metal bases (may cause source corrosion) Ammonium hydroxide is recommended Surfactants (surface active agents) Detergents and other surface active agents may suppress ionization Trifluoroacetic Acid (TFA) May enhance chromatographic resolution, but causes ion suppression in both negative and positive ion mode Isopropyl Alcohol May Enhance Negative Ion Formation 23
24 Buffers (ph) Avoid using non-volatile HPLC additives such as: Alkali Metal Phosphates Borates Citrates Keep Buffer concentrations below 20 mm using volatile salts such as ammonium acetate. When using buffers, more frequent cleaning of the heated capillary and API stack will be necessary 24
25 LC/MS Additives and Buffers Summary Acetic Acid Formic Acid Ammonium Hydroxide Ammonia Solutions Trichloroacetic Acid (< 0.1% v/v) Trifluoroacetic Acid (< 0.1% v/v) Isopropyl Alcohol (10% of organic phase) Ammonium Acetate Ammonium Formate Proton Donors Proton Acceptors Chromatographic Separation Negative ion formation Buffers 25
26 Common LC/MS Solvents Methanol Acetonitrile Water Isopropanol Dichloromethane Chloroform Hexane 26
27 Effects of Solvents and Additives on ESI Solvent System 50/50 ACN/H2O 0.1% NH4OH 50/50 MeOH/H2O 0.1% NH4OH 50/50 ACN/H2O 0.02% TFA 50/50 ACN/H2O 0.05% TFA 50/50 ACN/H2O 0.1% TFA 50/50 MeOH/H2O 0.02% TFA 50/50 MeOH/H2O 0.05% TFA 50/50 MeOH/H2O 0.1% TFA 50/50 MeOH/H2O 10mM NH4OAc 50/50 MeOH/H2O 5mM NH4OAc 50/50 ACN/H2O 0.1% Formic 50/50 ACN/H2O 1% Acetic 50/50 MeOH/H2O 0.1% Formic 50/50 MeOH/H2O 1% Acetic 100 ACN 100 MeOH 100 H2O 50/50 ACN/H2O 50/50 MeOH/H2O Tyr-Gly-Gly-Phe-Leu Leucine Enkephalin Counts (protonated ion species) 27
28 API Stack LCQ Classic, LCQ DUO, LCQ DECA LCQ DECA XP, LCQ Advantage 28
29 Ion Transfer Tube and Removal Tool Ion transfer tube Removal tool Heated capillary 29
30 Vent Prevent Mechanism Heated Tube in-situ Heated Tube removed Tungsten Vent Prevent 30
31 Ion Optics First multipole Lens Intermultipole Lens Second multipole Lens IONS IN IONS OUT Octapole Mount Vacuum Baffle Analyzer Mount 31
32 Multipole Potential Wells Mass Range Trans Efficiency Octapole Square Quadrupole Round Quadrupole 32
33 33 Mass Analyzer (Ion Trap)
34 Vacuum System Every mass analyzer must operate under vacuum in order to minimize both ion/molecule and molecule/ molecule collisions. At atmospheric pressure, the mean free path of a typical ion is only ca. 52 nm and at 1 mtorr,, it is 40 m. Without vacuum, the ions produced in the source won t make it to the detector. The LCQ vacuum is maintained by a both rotary and turbomolecular pumps 34
35 Ion Optics (Operating Pressures) 1.3 torr 760 torr 1.7x10-3 torr 2.0 x10-5 torr (1.0x10-5 torr He) 60 m 3 /hr 100 L/sec 3.5x10-3 torr He 220 L/sec 35
36 Steps to Ion Trap Scan Functions Trapping- all scans Isolation- SIM and MS n Excitation- MS n Ejection- all scans 36
37 Helium as a Damping Gas Without Helium With Helium He collision He He He He 37
38 38 Discovery of the Effects of Helium
39 39 Helium as a Damping Gas
40 Ion Trap Resolution Effect of Damping Gas Traps injected ions by removing kinetic energy Damps ion motion to center of trap Result... Increase in resolution and sensitivity 40
41 Helium Effect Helium flowing into trap S#:1 RT:0.00 AV:1 SM:7G NL:2.50E7 T: p Full ms m/z Abundance100 Relative S#:23-32 RT: AV:10 SM:7G NL:5.61E7 T: p Full ms Abundance100 Relative m/z Helium shut off and not flowing into trap S#:1 RT:0.02 AV:1 SM:7G NL:9.70E6 T: p Full ms 100 Relative Abundance S#:23-32 RT: AV:10 SM:7G NL:2.80E7 T: p Full ms m/z m/z 100 Relative Abundance
42 Ion Trap Stability Diagram The region shaded blue indicates a (DC) and q (RF) values which provide stable trajectories in the r-direction The region shaded yellow indicates the z-stable a and q combinations The green area where the r- and z-stable regions overlap indicates the a and q combinations under which ions will be stable in the trap 42
43 Stability Diagram for Commercial Traps V qz = k ( m/ e) 43
44 LCQ Scan-Out (Ejection) Rates Normal Scan (5500 amu/sec) Common full, SIM, or MS n (SRM and CRM) scanning Resolution (FWHM) = 0.50, Mass Accuracy = ± 0.05 Zoom Scan (280 amu/sec) Increases resolution and mass accuracy across a narrow range (allows charge state determination) Resolution (FWHM) = 0.15, Mass Accuracy = ± 0.02 Turbo Scan (55,000 amu/sec) Decreases total scan time of a full scan, thus increasing number of scans across a chromatographic peak Resolution (FWHM) = 3.0, Mass Accuracy = ± 0.5 Used for better quantitation due to an increase of scans across a chromatographic peak 44
45 What is AGC and Why Is it Important? Camera AE LCQ Series AGC Too much light degrades the image stored on film, causing a loss of color and image resolution. Too little light results in dark picture with no fine details visible. Cameras with high quality light meters and AE controls produce high quality pictures over a wide dynamic range of lighting conditions. Controls amount of ions (light) entering the ion trap (film) Too many ions degrade the spectral quality in the trap, causing loss in mass resolution and mass assignment. Too few ions result in poor sensitivity to low level or minor components. AGC ensures excellent quality MS, SIM and MS/MS spectra, as well as excellent sensitivity over a wide dynamic range. 45
46 Automatic Gain Control (AGC) Prescan before the analytical scan - Measures the # of ions in the trap for a pre-defined time (10 ms) -Allows software to determine optimum ion injection time 46
47 47 No AGC Spectrum of Ultramark 1621, Caffeine, MRFA Calibration Mixture space charging
48 48 Spectrum of Ultramark 1621, Caffeine, MRFA Calibration Mixture with AGC
49 AGC (Ion Population Control) ~ 300 Ions ~ 1500 Ions ~ 3000 Ions ~ 6000 Ions Relative Abundance m/z Relative Abundance Good Resolution m/z Relative Abundance m/z Relative Abundance m/z Poor Resolution
50 Calculation of Ion Time Constant During Prescan AGC Prescan Signal = Number of Ions x Multiplier Gain x Prescan Time (3 x 10 5 counts) (10 ms) Calculated Ion Time = (how long the gate lens is open ) Target Value AGC Prescan Signal 50
51 Triplicate Injection of 5 nmol of MRFA (AGC ON) Unscaled TIC (counts) Injection Time (ms) 2.0E08 1.8E08 1.6E08 1.4E08 1.2E08 1.0E08 8.0E07 6.0E07 4.0E07 2.0E07 0.0E Unscaled TIC Scan Number Injection Time Scaled TIC (counts) 0 8.0E08 7.0E08 6.0E08 5.0E08 4.0E08 3.0E08 2.0E08 1.0E08 0.0E Scan Number Scaled TIC Scan Number 51
52 7 Isolation of Ions Ion we wish to isolate 0.0 q z Ions at different q z values oscillate at different frequencies (ω o ) ω o q z Ω
53 Isolation Waveforms ~ m/z 200 q axis Hz 16 msec q axis
54 Why MS/MS or MSn? Signal to Noise Improvement Intensity Signal Noise S/N Stages of Analysis 54
55 MS/MS Parameters Precursor ion m/z Excitation voltage Excitation q z Intensity Precursor ion Σ(Product ions) Excitation Voltage (V)
56 Resonant Excitation q z Value q z Fragment ions not trapped Product Ion m/z Range Fragmentation Energy /4 q z /3 q z /2 56
57 Ion Trap Scan Functions 1. Collect 3. Fragment 2. Isolate 4. Eject 57
58 Summary (Ion Trap Functions) 1)Collection 2)Isolation 3)Excitation 4)Ejection For Scans: All By: Ring Electrode Method: Alternating RF frequency (760 khz) at a set amplitude along with He dampening gas traps and cools the ions to the center of the trap. 58
59 Summary (Ion Trap Functions) 1)Trapping 2)Isolation 3)Excitation 4)Ejection For Scans: SIM, MS n By: Endcap Electrodes Method: a) Tailored waveform applied to all ions in the trap except ion of interest b) Thus, only ions of interest remain in the trap. 59
60 Summary (Ion Trap Functions) 1)Trapping 2)Isolation 3)Excitation 4)Ejection For Scans: MS n By: Endcap Electrodes Method: a) Cool ion of interest back to set q value (default = 0.25). b) Apply custom RF waveform in resonance with the set q value, activation time (default = 30 msec), and optimized activation amplitude. 60
61 Summary (Ion Trap Functions) For Scans: All 1)Trapping 2)Isolation 3)Excitation 4)Ejection By: Ring Electrode Method: Ramp ring RF power to increase the q values of all ions in desired scan range, low mass to high mass. (i.e. Mass Selective Scanning) Also, ramp the RF amplitude on the endcap electrodes to consolidate the ions to a group (Resonance Ejection) 61
62 Tune Page convection gauge pressure < 1.5 torr? Ion gauge Pressure <2.0x10-5 torr? 62
63 ESI Calibration Solution Caffeine stock: MFRA stock: Ultramark stock: 10 ml acetonitrile 1 mg/ml in methanol Dissolve 3.0 mg MRFA in 1 ml 50:50 methanol:water Measure 10 υl of Ultramark 1621, and dissolve it in ESI calibration solution ESI calibration solution Into a clean vial pipette 100 µl of caffeine stock, 5 µl of MRFA stock and 2.5 ml of Ultramark stock. Add 50 µl of glacial acetic acid and 2.34 ml 50:50 methanol:water 63
64 64 Ion Trap Animation
65 The Eighth Generation Triple Quad TSQ 15, TSQ 45, TSQ 46, TSQ 70, TSQ 700, TSQ 7000, TSQ, TSQ Quantum 65
66 Smaller because 8degrees 90 Degree Square quad collision cell 25 cm quad TSQ cm quad 25 cm quad Quantum 25 cm quad 90 degrees 66
67 HyperQuads TM Hyperbolic Quadrupoles TSQ to 2000 r 0 = 4 mm L = 250 mm TSQ Quantum 2001 to r 0 = 6 mm L = 250 mm Forms Pure Quadrupolar Fields Reduces Fringing Effects Significantly Improves Resolution Improves Transmission Improves Peak Shapes 67
68 Quadrupole Mass Analyzer The ion is transmitted along the quadrupole in a stable trajectory Rf field. The ion does not have a stable trajectory and is ejected from the quadrupole. 68
69 How does the Quadrupole work? The quadrupole consists of four parallel rods. The opposing rods have the same polarity while adjacent rods have opposite polarity. Each rod is applied with a DC and an RF voltage. Ions are scanned by varying the DC/Rf quadrupole voltages. Only ions with the selected mass to charge ratio will have the correct oscillatory pathway in the Rf field. -ve ve 69
70 Effect of Peak Width On Transmission HYPERQUAD ROUND RODS % T r a n s m i s s i o n Peak Width FWHM 70
71 Effect of Peak Width on Resolution Resolution Quad 0.7 FWHM Quad 0.1 FWHM Sector Quantum operating at 0.1 FWHM at m/z 1000 R = 10,000 Quantum, API 4000, Ultima at 0.7 FWHM at m/z 1000 R = 1428 R is relatively flat across m/z m/z 71
72 The Power of Resolution Separation of ions with same nominal m/z value Unequivocal determination of charge state (ESI) High resolution precursor ion selection for MS/MS High resolution product ion for charge state determination 72
73 Effect of changing resolution on peak shape 1.0 FWHM 0.7 FWHM 0.5 FWHM 0.3 FWHM 0.2 FWHM 0.1 FWHM 73
74 Resolution vs. Intensity 1.0 FWHM 0.7 FWHM 0.5 FWHM 2.5e6 2.1e6 1.9e6 74
75 Resolution vs. Intensity 0.3 FWHM 0.2 FWHM 0.1 FWHM 1.5e6 1.4e6 0.8 e6 75
76 Quadrupole Mass Analyzer If one MS scan between m/z 100 and 500 is completed in one second, then each m/z will be allowed to pass for 2.5 ms ms = 2.5 ms/amu 400 amu To detector 76
77 Quadrupole Mass Analyzer And, for the same peak, for example, the quadrupole performs 5 complete scans from Da each taking 1 sec Da Da Da Da Da 77 5 sec
78 Ion Trap Pre-Scan The length of time that the trap stays open to collect ions is determined by a pre-scan which measures total ion current (prevents space charging, so no ghost peaks ) Pre-Scan 78 5 sec
79 Ion Trap Pre-Scan Cont d Across a peak 5 sec. wide the trap might fill and empty 5 times. So, a group of ions are collected ca. every 1 sec each group is then ejected to the detector, smaller ions first. 1 sec 1 sec 1 sec 1 sec 1 sec 79 5 sec
80 Comparison of Quads and Traps For the quadrupole, each m/z is scanned (sequentially) to the detector for 2.5 ms. But for a trap, each m/z (and all m/z at the same time) is/are collected for ca. 750 ms (taking pre-scan and interscan times into account) and then scanned to the detector. 80
81 Comparison of Quads and Traps At any one particular instant, a quad will only scan/look for only one m/z. All other m/z will be ignored. In this example, each m/z is scanned for 2.5 ms. A trap will fill similar to filling a glass with water. All ions entering the trap will be collected until the trap fills with a pre-defined amount of ions (AGC target value). 81
82 Comparison of Quads and Traps So, for full scan MS, a trap will give better sensitivity because there are more ions representing each m/z arriving at the detector for each scan. 82
83 How Much More??? Accounting for pre-scan/interscan timing, the trap produces ca. 300 times (750 ms/2.5 ms) for the collection of each m/z compared to a quadrupole (i.e 2 orders of magnitude). 83
84 But What if I wanted to pass (filter) only one m/z ion to the detector (i.e. SIM or SRM) then I could spend more time on that ion 84
85 Comparison of Quads and Traps Yes, on a quadrupole, interscan times are relatively short and so the quadrupole remains fixed on that one ion a duty cycle of close to 100% But a trap will still only collect ions in batches - and prescan/interscan times afford a duty cycle of about 75% 85
86 What is a Duty Cycle? Definition:- Time taken to acquire 1 scan and be ready to acquire the next one Duty Cycle Scan 1 ISD Scan 2 Interscan delay (ISD) is the time taken to return all system voltages to the start values and reach a stable state This is dead time and should be minimized 86
87 In Addition While the beam instrument is continuously detecting one particular m/z a trap builds a curve from an average over each collection time and the points are least frequent at the most important region for quantitation (the take off ). 87
88 For Example SRM of 5 pg Alprazolam with LCQ Deca gives a %RSD of 6.11 while SRM of 750 fg Alprazolam with TSQ 7000 gives a %RSD of Signal to noise ratio (S/N) are similar (20:1 and 28:1 respectively). 88
89 Relative Abundan ce %RSD 6.11 RT: 4.26 SN: 20 SRM 5pg Alprazolam with LCQ Deca 100 SRM 750fg Alprazolam with TSQ RT: 4.41 SN: %RSD Time (min)
90 The Effect of Ion Trap Scan Speeds on Quantitative Performance In general, faster scanning produces more points across a chromatographic peak, hence better precision and lower LOQ s. In fact, for an ion-trap, scan speed refers only to the time taken to scan ions from the trap during mass analysis. Scan speed does not refer to the total analytical cycle. In an ion trap device, an MS n analytical scan comprises at least four events: 90
91 The Effect of Ion Trap Scan Speeds on Quantitative Performance 1- AGC Pre-scan 2- Ion Injection (usually the rate-determining step) 3- Isolation and activation of the parent ion within the trap 4- Scanning the ions out of the trap (mass analysis) 91
92 MS Scan Function Ion isolation Mass Analysis Ion Activation Ion Injection AGC Prescan Analytical Scan 92
93 Scan Terminology Prescan Mass Analysis Prescan Mass Analysis Prescan Mass Analysis 1st Microscan 2nd Microscan 3rd Microscan Save Data Complete Scan Cycle 93
94 The Effect of Ion Trap Scan Speeds on Quantitative Performance The injection time constitutes the majority of the total scan time. For good quantitative reproducibility, it is necessary to take enough points to precisely determine the chromatographic peak particularly at the take-off point. Increasing the scan speed in the trap does not significantly increase the number of data points taken across the peak. 94
95 Scan speeds in ion traps Pre-scan Quantitation m/z 500 scanning Isol /Activ // Download msec Pre-scan , msec amu/sec Isol /Activ // Download Injection time Pre-scan msec 13,000 Total amu/sec scan time Isol/Activ/ Download Injection 80 time 80 Scans // sec 500 wide peak Total amu/sec 70 scan time Injection time Scans 500 // sec wide peak Total scan time 710 Scans // sec wide peak
96 The Effect of Ion Trap Scan Speeds on Quantitative Performance The only significant way to increase the sampling rate across the peak is to reduce the injection time which can be achieved in two ways: 1- Set a lower max injection time which reduces the number of ions in the trap, hence sensitivity 2- Increase the efficiency of the source and lenses to improve the transmission of ions; I.e filling the trap to the same level in a shorter period of time. 96
97 Data Dependant Acquisition of MS n Spectra Data Dependant Acquisition: Intelligent decision-making software that selects precursor ion for MS n experiments based on user-define criteria. Critical for metabolite screening experiments. Scan event 1 Full-Scan MS Scan event 2 Full-Scan MS 2 Software selects most intense ion from scan event 1 as precursor ion for ms 2 experiment in scan event 2, provide that its intensity is above a user selected threshold m/z m/z 97
98 Dynamic Exclusion -- MS and MS/MS of Co-Eluters MS MS MS MS/MS MS MS/MS MS MS MS Threshold 231 MS/MS MS Time m/z MS/MS 377 m/z 98 m/z m/z
99 Comparison of Quads and Traps Major Strengths of Triple Quads SRM Sensitivity Neutral Loss Scan Mode Parent (Precursor) Scan Mode Major Strengths of the LCQ Deca XP Plus MS n Scan Mode Full Scan MS/MS Sensitivity Consecutive Reaction Monitoring (CRM) 99
100 What are neutral loss scans? Both Q1 and Q3 are scanned together Q3 is offset by the neutral loss under investigation The precursor ions collide with Argon gas in Q2 to create fragment ions Only those compounds which give a fragment having that specific loss are detected Since both Q1 and Q3 are scanning, neutral loss scan mode is slower than any other mode 100
101 Neutral loss scans Neutral loss scans are used for screening experiments where a group of compounds all give the same loss H 2 N -m/z 84 H 2 N N -m/z 84 N N N H 2 N N H 2 N N H 2 N NH 2 N N -m/z 84 H 2 N NH 2 N HO N N -m/z 84 HO N 101
102 What are precursor ion scans? Precursor ion scans also known as parent ion scans Q1 is scanned Q3 is set to allow only a fragment ion of one m/z to pass; (Q3 fixed) ions collide with Argon gas in Q2 to create fragment or product ions Only those compounds which give that specific fragment ion are detected 102
103 Precursor ion scans Precursor ion scans are used for screening experiments where a group of compounds all give the same fragment ion m/z 162 N N H 2 N m/z 192 N H 2 N N H O N N m/z 192 N N N m/z 84 H 2 N H 2 N N N m/z 268 m/z
104 Comparison of MS n in a Triple Quad verses an Ion Trap Instrument. Triple Quad(nonresonant excitation): Acceleration voltage applied equally to all masses. Get a mix of ms 2, ms 3 ms n products. Ion Trap(resonant excitation): Excitation energy is in resonance with only one mass at a time. Fragments, once formed, can not be further excited unless they are purposely selected for next stage of MS. Allows one to take apart a molecule in a controlled, step-wise fashion. 104
105 Comparison of Quads and Traps Ion Traps Quadrupoles Mass Separation in time Mass Separation in space High sensitivity Full Scan Lower sensitivity Full Scan Lower sensitivity SIM and SRM Offer multiple stages of MS n High sensitivity SIM and SRM Offers Only MS or MS/MS Parent and neutral loss scans 105
Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications
Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications Triple Stage Quadrupole API MS / MS Full Scan Products / - IONS AND NEUTRALS FORMED IN API SOURCE Q0 LENS TRANSPORTS
More informationQuadrupole and Ion Trap Mass Analysers and an introduction to Resolution
Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution A simple definition of a Mass Spectrometer A Mass Spectrometer is an analytical instrument that can separate charged molecules according
More informationMore structural information with MS n
PRODUCT SPECIFICATIONS The LTQ XL linear ion trap mass spectrometer More structural information with MS n The LTQ XL linear ion trap mass spectrometer delivers more structural information faster and with
More informationIntroduction to LC/MS/MS
Trends in 2006 Introduction to LC/MS/MS By Crystal Holt, LC/MS Product Specialist, Varian Inc. Toxicology laboratories Increased use of LC/MS Excellent LD Cheaper (still expensive) Much more robust Solves
More informationImpurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF
Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE
More informationAgilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value
Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels
More informationLECTURE 3. Ionization Techniques for Mass Spectrometry
LECTURE 3 Ionization Techniques for Mass Spectrometry Jack Henion, Ph.D. Emeritus Professor, Analytical Toxicology Cornell University Ithaca, NY 14850 Lecture 3, Page 1 Contents Electron ionization (EI)
More informationO O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions
Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism
More informationQuantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System
Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for
More informationMSQ. Hardware. Document No Revision 02 October 2003
MSQ Hardware Document No. 031871 Revision 02 October 2003 2003 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America. This publication is protected by federal copyright
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Sean Orlowicz LC/MS Product Specialist Agilent Technologies 31August Agilent s > 40 year heritage in mass spectrometry 1971, 5930A GC/MS 1971-2011 2005,
More informationMethods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University
Methods in Mass Spectrometry Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University Sample Engineering Chemistry Biology Life Science Medicine Industry IDF / Police Sample
More informationIdentification of Haemoglobinopathies by LC/MS
Identification of Haemoglobinopathies by LC/ Mark Harrison; Senior Scientist, ThermoFisher Scientific Sarah Battle; Senior Biomedical Scientist, Royal Hallamshire Hospital Introduction There are over 2
More informationIncreased Identification Coverage and Throughput for Complex Lipidomes
Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive
More information2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry
Dr. Sanjeeva Srivastava 1. Fundamental of Mass Spectrometry Role of MS and basic concepts 2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry 2 1 MS basic concepts Mass spectrometry - technique
More informationMS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for
More informationSingle Quadrupole Compact Mass Spectrometer for Liquid Sample
Single Quadrupole Compact Mass Spectrometer for Liquid Sample YL INSTRUMENT CO., LTD. YL9900 MS quickly provides essential information and improves the chemist's workflow. Mordern organic labs have become
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationSample Concentration and Analysis of Human Hormones in Drinking Water
Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationLC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for
POSTER NOTE 64921 LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for Research Use LC-MS/MS quantitative analysis of Poly Rory M Doyle*, Thermo Scientific, Inc,
More informationRobust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS
TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo
More informationSupporting information
Supporting information Figure legends Supplementary Table 1. Specific product ions obtained from fragmentation of lithium adducts in the positive ion mode comparing the different positional isomers of
More informationSCS Mass Spectrometry Laboratory
SCS Mass Spectrometry Laboratory Contact Information Staff 31 Noyes Laboratory (8:00-5:00 M-F) 217-333-2545 http://scs.illinois.edu/massspec/ Furong Sun (frs@illinois.edu) Furong Sun Director Training
More informationAutomated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222
Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Joan Stevens, Ph.D.; Luke Roenneburg; Tim Hegeman; Kevin Fawcett
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationLipidomic Analysis by UPLC-QTOF MS
Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material
More informationAdvancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations
Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research
More informationPosterREPRINT EVALUATION OF A RF-ONLY STACKED RING BASED COLLISION CELL WITH AXIAL FIELD FOR THE LC-MS-MS ANALYSIS OF THE METABOLITES OF RABEPRAZOLE
OVERVIEW Comparison of the performance of a stacked ring based collision cell with axial field and a hexapole collision cell. Full scan LC-MS/MS-MS using precursor, product and neutral loss modes of operation
More informationDetermination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis
Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis UCT Product Number: ECQUEU75CT-MP - Mylar pouch containing extraction
More information[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS
Yun Wang Alelyunas, Henry Shion, Mark Wrona Waters Corporation, Milford, MA, USA APPLICATION BENEFITS mab LC-MS method which enables users to achieve highly sensitive bioanalysis of intact trastuzumab
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More informationDetermination of Amantadine Residues in Chicken by LCMS-8040
Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole
More informationMass Spectrometry. Actual Instrumentation
Mass Spectrometry Actual Instrumentation August 2017 See also http://www.uni-bielefeld.de/chemie/analytik/ms f additional infmation 1. MALDI TOF MASS SPECTROMETRY ON THE ULTRAFLEX 2 2. ESI MASS SPECTROMETRY
More informationAnalysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN
Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words
More informationLC/MS/MS Analysis of Gabapentin, and Opiates. Applications. Presentation Outline. Polarity, MW and Volatility LC/MS Triple Quad Components
Presentation Outline LC/MS/MS Analysis of Gabapentin, LC/MS/MS Benzodiazepines, Introduction and Applications and Opiates Brian Nies LC/MS Product Specialist Varian Inc. Winter CAT Meeting Redondo Beach
More informationQSTAR Operation. May 3, Bob Seward
QSTAR Operation May 3, 2005 Bob Seward Presentation CD Contents QSTAR Hardware QSTAR Schematic 10-7 torr QSTAR Schematic Chernushevich et al, JMS 2001, 36: 849-865 Curtain Plate ESI Source ESI Source Curtain
More informationFundamentals of Soft Ionization and MS Instrumentation
Fundamentals of Soft Ionization and MS Instrumentation Ana Varela Coelho varela@itqb.unl.pt Mass Spectrometry Lab Analytical Services Unit Index Mass spectrometers and its components Ionization methods:
More informationAnalyzing Phenyl Ureas and Carbamates with HPLC/API-MS. Presented by Chen-Kai Meng, Ph.D. Applications Chemist
Analyzing Phenyl Ureas and Carbamates with HPLC/API-MS Presented by Chen-Kai Meng, Ph.D. Applications Chemist Outline Overview of ESI, APPI, and APCI sources Comparing ESI, APPI, and APCI results Identifying
More informationRapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition
Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble
More informationPHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,
PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES DR. A. RAMESH, Ph.D, D.Sc., raamesh_a@yahoo.co.in 1 OBJECTIVES Determination of persistence and photolysis
More informationFOURIER TRANSFORM MASS SPECTROMETRY
FOURIER TRANSFORM MASS SPECTROMETRY https://goo.gl/vx3ogw FT-ICR Theory Ion Cyclotron Motion Inward directed Lorentz force causes ions to move in circular orbits about the magnetic field axis Alan G. Marshall,
More informationApplication Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer
Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Abstract This study demonstrates a sensitive, rapid and reliable research
More informationComponents of a Mass Spectrometer
Components of a Mass Spectrometer Sample Introduction Inlet GC LC Direct Insertion (Syringe/Probe) Ionization Ion Separation Ion Detection Ion Source EI,CI,,, MALDI Mass Analyzer Under vacuum TOF, Quadrupole,
More informationSYNAPT G2-S High Definition MS (HDMS) System
SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business
More information1. Sample Introduction to MS Systems:
MS Overview: 9.10.08 1. Sample Introduction to MS Systems:...2 1.1. Chromatography Interfaces:...3 1.2. Electron impact: Used mainly in Protein MS hard ionization source...4 1.3. Electrospray Ioniztion:
More informationRapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer
Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical
More informationStrengthening Results. Advanced Chromatography with Mass Detection
Strengthening Results Advanced Chromatography with Mass Detection UV Detection Why Not Use UV For Everything? Identification Difficult selectivity in complex matrices Sensitivity Need sufficient molar
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationNeosolaniol. [Methods listed in the Feed Analysis Standards]
Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]
More informationBreaking the Sensitivity Barrier in Triple Quad LC/MS Performance
Breaking the Sensitivity Barrier in Triple Quad LC/MS Performance Tim Schlabach Alex Mordehai Michael Zumwalt Page 1 Sensitivity enhancements for ESI-MS Reduce the column diameter! 30 fold gains in sensitivity
More informationApplying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis
Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS
More informationIonization Methods. Neutral species Charged species. Removal/addition of electron(s) Removal/addition of proton(s)
Ionization Methods Neutral species Charged species Removal/addition of electron(s) M + e - (M +. )* + 2e - electron ionization Removal/addition of proton(s) M + (Matrix)-H MH + + (Matrix) - chemical ionization
More informationDetection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS
Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS Olga Shimelis, An Trinh, and Michael Ye Supelco, Div. of Sigma-Aldrich, Bellefonte, PA T407125 Introduction Molecularly
More informationIdentification of Steroids in Water by Ion Trap LC/MS/MS Application
Identification of Steroids in Water by Ion Trap LC/MS/MS Application Environmental Author Paul Zavitsanos and Christine Miller Agilent Technologies, Inc. Centerville Road Wilmington, DE 9- USA Abstract
More informationEdgar Naegele. Abstract
Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in
More informationMetabolomics Strategies
Metabolomics Strategies using GC-MS/MS-Technology Hans-Joachim Hübschmann GC/MS Technology Manager, Austin/Singapore Proteomics/Metabolomics Seminars March 2012 Thermo Scientific GC and GC-MS Product Line
More informationQuantification of PtdInsP 3 molecular species in cells and tissues by mass spectrometry
Nature Methods Quantification of PtdInsP 3 molecular species in cells and tissues by mass spectrometry Jonathan Clark, Karen E Anderson, Veronique Juvin, Trevor S Smith, Fredrik Karpe, Michael J Wakelam,
More informationAutomated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System
Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography
More informationPosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT
ABSTRACT The traditional study of in vivo drug metabolism in plasma or urine samples is often complicated by the presence of many endogenous compounds. Several mass spectrometric techniques are often applied
More information2D-LC as an Automated Desalting Tool for MSD Analysis
2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja
More informationMass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010
Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010 Introduction, Ionization Methods Mass Analyzers, Ion Activation Methods
More informationVitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid
Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from
More informationPolymer Additive Analysis by EI and APCI
Polymer Additive Analysis by EI and APCI Kate Yu, Eric Block LC/MS Waters Corporation Introduction to polymer additive analysis by LC/MS. Electron Ionization (EI) Advantages Classical spectra Library searchable
More informationDienes Derivatization MaxSpec Kit
Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION
More informationA NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.
A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin
More informationAnalysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS
Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS UCT Part Numbers ECQUEU7-MP Mylar pouch containing 4g MgSO4, 1g NaCl, 1g Na3Cit 2H2O and 0.5g Na2Cit 1.5H2O CUMPSC1875CB2CT 2mL dspe tube
More informationSupporting Information (SI)
Electronic Supplementary Material (ESI) for Analyst. This journal is The Royal Society of Chemistry 2015 Supporting Information (SI) Title: Optimization of Metabolite Extraction of Human Vein Tissue for
More informationVitamin D3 and related compounds by ESI and APCI
Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationSue D Antonio Application Chemist Cedar Creek, TX
Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis
More informationNew Mass Spectrometry Tools to Transform Metabolomics and Lipidomics
New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics July.3.13 Ken Miller Vice President of Marketing, Life Sciences Mass Spectrometry 1 The world leader in serving science Omics & the
More informationDetection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer
APPLICATION NOTE 72819 Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer Author Maria Grübner; Thermo Fisher Scientific, Germering,
More informationResults of Using Re-washed Vials and Closures
Results of Using Re-washed Vials and Closures Loy Shick, Thermo Fisher Scientific, Rockwood, TN, USA Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20670 Key Words Autosampler,
More information[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS
[ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,
More informationMaking your LC Method Compatible with Mass Spectrometry
Making your LC Method Compatible with Mass Spectrometry Technical Overview Author Edgar aegele Agilent Technologies, Inc. Waldbronn, Germany Introduction The power of traditional high-performance liquid
More informationRobust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS
Application Note 242 Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS INTRODUCTION Tobacco-specific nitrosamines (TSNA) are a group of carcinogens found only in tobacco products. They
More informationMass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors
Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification,
More informationAmadeo R. Fernández-Alba
% of compounds % of compounds % of compounds % of compounds Amadeo R. Fernández-Alba LC-Orbitrap QExactive Focus Instrumental LOQ 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% %.1 mg/g.2 mg/g Tomato.5 mg/g ddms2 Target
More informationCONTENT. i iv ix. SVKM s NMIMS, School of Pharmacy and Technology Management
CONTENT Chapter No. Title Page No. Abbreviations List of Figures List of Tables 1 Introduction 1 1.1 Practical aspects 4 1.2 Stability-indicating assay method (SIAM) 5 1.3 Regulatory aspects 6 1.4 Techniques
More informationOMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (10) 86 2R QUALIFICATION OF EQUIPMENT ANNEX 7: QUALIFICATION OF MASS SPECTROMETERS Full document title and reference Document
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationParent and Neutral Loss Monitoring on a Quadrupole Ion Trap Mass Spectrometer: Screening of Acylcarnitines in Complex Mixtures
Anal. Chem. 2002, 74, 5799-5806 Parent and Neutral Loss Monitoring on a Quadrupole Ion Trap Mass Spectrometer: Screening of Acylcarnitines in Complex Mixtures Joseph E. McClellan, Scott T. Quarmby, and
More informationExtraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis
Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More informationMOMA: Mars Organic Molecule Analyzer Luann Becker Johns Hopkins Physics and Astronomy Harsh Environment Mass Spectrometry Workshop September 23rd
MOMA: Mars Organic Molecule Analyzer Luann Becker Johns Hopkins Physics and Astronomy Harsh Environment Mass Spectrometry Workshop September 23rd 2009 Strategy for Future Missions to Mars - Lessons learned
More informationJose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK
HIGH-THRUGHPUT REACTIVE METABLITE SCREEIG FR DICLFEAC BY UPLC AD XEV TQ MS WITH SCAWAVE Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford,
More informationSulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms
Supporting Information for Sulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms Submitted by Yong Feng, Deli
More informationUsing Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.
Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in
More informationUPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
More informationImproving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer
Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer Overview Increased selectivity is achieved in quantitative analysis by using MS 3. The
More informationCHAPTER-6 IDENTIFICATION, AND CHARACTERISATION OF DEGRADATION IMPURITY IN VALSARTAN TABLETS
129 CHAPTER-6 IDENTIFICATION, AND CHARACTERISATION OF DEGRADATION IMPURITY IN VALSARTAN TABLETS 130 6.1. Introduction Valsartan is an orally active specific angiotensin II blocker effective in lowering
More informationMetabolomics: quantifying the phenotype
Metabolomics: quantifying the phenotype Metabolomics Promises Quantitative Phenotyping What can happen GENOME What appears to be happening Bioinformatics TRANSCRIPTOME What makes it happen PROTEOME Systems
More informationAnalysis of several common. organic acids in tobacco leaf, snus, and moist snuff
Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are
More informationComprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids
PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki
More informationUltra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification
22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and
More informationAnalysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF
Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF Application Note 219 Joan Stevens, PhD; Luke Roenneburg; Kevin Fawcett (Gilson,
More informationOzonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination
Ozonolysis of phospholipid double bonds during electrospray ionization: a new tool for structure determination Michael C. Thomas, Todd W. Mitchell, Stephen J. Blanksby Departments of Chemistry and Biomedical
More informationDon t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry
Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry Kai Scheffler, PhD BioPharma Support Expert,LSMS Europe The world
More information