Direct determination of MCPD esters and glycidyl esters by LC-TOFMS
|
|
- Virginia Hill
- 6 years ago
- Views:
Transcription
1 1 AOCS Meeting May 16-19, Phoenix, AZ Direct determination of MCPD esters and glycidyl esters by LC-TOFMS Mark W. Collison, Ph. D., Director, Analytical Chemistry, Troy Haines, Analytical Laboratory Manager, ADM Research
2 2 What are MCPD and glycidol? Monochloropropanediol - Byproduct found in in soy sauce and hydrolyzed vegetable protein produced by HCl digestion - Also reported previously in HCl hydrolyzed oils - Reported in the last several years to be widespread in vegetable oils using chemical tests. Glycidol - Also reported to be present in vegetable oils by the same chemical tests.
3 MCPD Esters and Glycidyl Esters 3
4 4 Chemical Methods of Analysis Fat + Sodium Methoxide FAME + glycerol etc. Acidify and extract using concentrated sodium chloride to partition (converts glycidol to MCPD) React with phenylboronate or other derivatizing agents Analyze MCPD-phenylboronate by GCMS. The DGF chemical method will be the one we compared with: DGF c-iii_18 _09_e14 Alternative procedure utilized acid hydrolysis
5 5 Why Develop an LCMS method? The DGF method does not work adequately. -ISTD recovery is acceptable ONLY if NaCl is used in the wash -Loss of virtually all ISTD if Na 2 SO 4 is used in the wash -Conversion to the brominated form if NaBr is used in the wash. The DGF method claims the method analyzes the total of MCPD plus glycidol, but MCPD and glycidol have not been shown to be the only precursors that can produce MCPD under the reaction conditions. The difference between the two treatments in the DGF method has been implied as a measure of glycidol, but there is no evidence glycidol is the only substance which contributes to this difference in results. LCMS provides direct analysis of MCPD mono-esters and di-esters and glycidyl esters without chemical modifications that can give incorrect results. LCMS provides very specific correct identification of analytes. LCMS allows use of isotopic internal standards for very accurate analysis.
6 Effect of Salts on the DGF method Loss of MCPD in the absence of chloride 6
7 Effect of Salts on the DGF method Conversion of MCPD to MBPD in the presence of bromide 7
8 8
9 9 LC-TOFMS Method for MCPD esters and glycidyl esters MCPD diesters do not ionize well to MH+ ions by either ESI or APCI Current approach was used previously for diglycerides [1] Low concentration of sodium acetate (~26 µm) in the mobile phase allows ESI ionization and detection of sodiated ions [MNa+] High resolution TOF-MS detection allowed elimination of background interferences for certain MCPD esters. -Eliminated by setting m/z resolution to 50 ppm (±0.016 da) [1] Hannah L. Callender, Jeffrey S. Forrester, Pavlina Ivanova, Anita Preininger, Stephen Milne, and H. Alex Brown, Quantification of Diacylglycerol Species from Cellular Extracts by Electrospray Ionization Mass Spectrometry Using a Linear Regression Algorithm Anal. Chem. 2007, 79,
10 10 LC-TOFMS Detects both mono- and di-esters of MCPD Detection limit for diester standards is µg/kg Limit of quantitation for total MCPD esters in vegetable oil samples is about ~500 µg/kg (~100 µg/kg MCPD equivalent concentration) Method also optimized for detection of glycidyl esters Detection Limit of individual GS standards is ~5 µg/kg Limit of quantitation for total glycidyl esters in vegetable oils ~200 µg/kg (~40 µg/kg glycidol equivalent concentration)
11 11 Standards 3-MCPD monopalmitate, 3-MCPD monostearate, 3-MCPD dipalmitate, were purchased from Toronto Research Chemicals, Inc (North York, ON, Canada). Glycidyl stearate was purchased from TCI America (Portland, OR, USA). Glycidyl linolenate, glycidyl linoleate, glycidyl oleate and glycidyl palmitate were purchased from Wako Pure Chemical Industries (Tokyo, Japan). Glycidyl-31d-palmitate synthesized enzymatically as internal standard for glycidyl esters 3-MCPD mono- and diesters of oleic, linoleic and mixed fatty acids, and deuterated internal standard (dioleyl-d5-mcpd), and glycidyl esters of palmitic, oleic and mixed fatty acids were synthesized enzymatically.
12 12 LC and TOF-MS conditions Methanol-Sodium Acetate - Methanol containing 0.26 mm sodium acetate was prepared by adding 21.3 mg sodium acetate to 1 liter methanol. HPLC Mobile Phase A - 90% methanol 10% acetonitrile with mm sodium acetate. Mix 100 ml Methanol-Sodium Acetate, 800 ml methanol and 100 ml acetonitrile. HPLC Mobile Phase B - 80% methylene chloride 10% methanol 10% acetonitrile with mm sodium acetate. Mix 100 ml Methanol-Sodium Acetate, 800 ml methylene chloride and 100 ml acetonitrile. ISTD solution: 2030 µg/ml dioleyl-d5-mcpd and 180 µg/ml glycidyl 31dpalmitate in HPLC Mobile B Sample Preparation: -In a 12 x 32 HPLC vial, accurately weigh 1 drop (~20-25 mg) oil -Add 975 µl ISTD Solution.
13 13 LC and TOF-MS conditions HPLC Column: Phenomenex Luna 3 µm C18,100Å, 50 x 3.0 mm. Flow Rate ml / min. TOF-MS Agilent 6210 TOF-MS upgraded to 4 GHz - ESI at 3.5 kv - Gas Temp. 300 C - Drying Gas 5 L/min. - Nebulizer Pressure 50 psi - Mass Range 300 to 700 m/z Gradient Programming Run Time % B 0 min. 0 5 min min min min. 100 Polarity Positive, Instrument Mode 4 GHz, Data Storage - Centroid Monoheptadecanoin and Dinonadecanoin as Mass Reference Ions
14 14
15 571 ppb Glycidyl Palmitate 485 ppb Glycidyl Stearate 568 ppb Glycidyl Oleate 478 ppb Glycidyl Linoleate 444 ppb Glycidyl Linolenate 15
16 5693 ppb 3-MCPD Monopalmitate 2338 ppb 3-MCPD Monostearate ppb 3-MCPD Monooleate ppb 3-MCPD Monolinoleate 1516 ppb 3-MCPD Monolinolenate 16
17 7180 ppb 3-MCPD Palmitic-Palmitic Diester 4347 ppb 3-MCPD Oleic-Oleic Diester ppb 3-MCPD Oleic-Linoleic Diester 6935 ppb 3-MCPD Linoleic-Linoleic Diester 2022 ppb 3-MCPD Linoleic-Linolenic Diester 2030 ppb d5-3-mcpd Oleic-Oleic Diester (ISTD) 17
18 732 ppb 3-MCPD Palmitic-Oleic Diester 924 ppb 3-MCPD Palmitic-Linoleic Diester 251 ppb 3-MCPD Oleic-Stearic Diester 147 ppb 3-MCPD Linolenic-Linolenic Diester 135 ppb 3-MCPD Palmitic-Linolenic Diester 18
19 19 Typical Standard Curve GL, ng/ml
20 20 MCPD Ester and Glycidyl Ester Content of Commercial Vegetable Oils Samples are from a variety of producers and were obtained from grocery stores and commercial suppliers
21 21 Results for Commercial Refined Oils MCPD monoesters are never found in deodorized vegetable oils. Glycidol is not likely to be the precursor of MCPD esters in commercial vegetable oils. MCPD diesters have not been found in commercial vegetable oils other than some samples of palm oil. Glycidyl esters were found in significant quantities in some commercial vegetable oils.
22 22 DGF Method compared to LCMS method DGF method predicts higher total MCPD + glycidol concentrations than LCMS when MCPD esters and / or glycidyl esters are present. DGF Method still gives positive results even when MCPD and glycidyl esters are not detected by LC-TOFMS.
23 23 MCPD Esters can form from contact with hydrochloric acid under mild conditions. Conditions of acid treatment: 0.1 v/wt% acid, 2 min shear mix, 60 min stir mix, 70 C, water wash to neutral Note that glycidyl stearate was not destroyed during this mild acid treatment and was not the precursor for MCPD formation.
24 24 MCPD Esters can form from contact with HCl treated adsorbents during vegetable oil processing * manufacturers confirmed that HCl was used in the acid washing Samples deodorized after treatments at 260 C, 30 min, 3 mm Hg, 3% steam sparge. Original experiment was an attempt to remove precursors of glycidyl esters and MCPD esters. RB Palm Oil was free of detectable MCPDE and GE prior to the experiment
25 25 Glycidyl esters Diglyceride content seems to correlate somewhat with glycidyl ester content. High diglyceride content in oils predisposes them to formation of glycidyl esters
26 26
27 27 Challenges in getting correct results from the LC-TOFMS method The instrument gets dirty quickly from the sodium in the mobile phase and requires a quick cleaning every day prior to use. More extensive cleaning is required weekly in heavy use. Certain parts in the ESI source corrode quickly and require frequent replacement. ESI Nebulizer needles are replaced weekly in heavy use. Close attention to internal standard areas and frequent check standards are needed to be certain that loss of intensity has not occurred.
28 28 Conclusions The harsh chemistry of the DGF method creates incorrect results in the analysis of MCPD and glycidyl esters. Chemistry capable of transesterifying oils needs to be avoided in analysis of MCPD and glycidyl esters. Direct analysis by LCMS looks extremely promising. MCPD esters can form from contact with hydrochloric acid and from acid washed absorbents during vegetable oil processing. Glycidyl esters are widely present in vegetable oils. Glycidyl esters seem to be a much more widespread issue than MCPD esters. Glycidyl esters are not the precursor of MCPD esters. High diglyceride content predisposes oils to glycidyl ester formation Glycidyl esters and MCPD esters can be greatly reduced by processing.
29 Laboratory treatments of soy, corn and palm oil MCPD diesters found by LC-TOFMS 29
30 30 Recent Research GCMS Confirmation of the MCPD esters found by LC-TOFMS. - Samples were injected on a DB5 column, analyzed by MS on a Shimadzu QP-2010 Plus - Samples that were negative by LC-TOFMS for MCPD esters had no detectable MCPD esters by GCMS - Samples which were positive for MCPD esters by LC- TOFMS showed the same detectable MCPD esters by GCMS - Difficult to maintain sensitivity due to detector fouling - Complete chromatographic resolution of MCPD esters from corresponding glycerides is essential
31 31 Atmospheric Pressure Photoionization (APPI) Utilizes UV light to ionize nebulized samples. Syagen is the patent holder and makes all APPI sources currently sold. M + hν M + + e - MH + ions are normally seen, though M + ions are sometimes seen. M + + SH MH + + S
32 32 APPI MCPD monoesters and glycidyl esters All of which have identical LCMS spectra Addition of acetone as a dopant increases response of MCPD monoesters and glycidyl esters and decreases response of monoglycerides
33 33 APPI MCPD diesters Favored reaction for saturated diesters Favored reaction for unsaturated diesters Addition of acetone as a dopant increases response of MCPD monoesters and glycidyl esters and decreases response of monoglycerides
34 34
Direct Determination of MCPD Fatty Acid Esters and Glycidyl Fatty Acid Esters in Vegetable Oils by LC- TOFMS
Direct Determination of MCPD Fatty Acid Esters and Glycidyl Fatty Acid Esters in Vegetable Oils by LC- TOFMS Troy D. Haines, Kevin J. Adlaf, Robert M. Pierceall, Inmok Lee, Padmesh Venkitasubramanian and
More informationUpdate on the Development of a Sensitive, Accurate, and User- Friendly Method for the Direct Determination of 3-MCPD 3
Update on the Development of a Sensitive, Accurate, and User- Friendly Method for the Direct Determination of 3-MCPD 3 Esters J. D. Pinkston, P.J. Stoffolano, P. Y. Lin The Procter & Gamble Company, Winton
More informationCurrent status of MCPD and Glycidol Analysis in Oils
Current status of MCPD and Glycidol Analysis in Oils Mark W. Collison, Ph. D., Director, Analytical Chemistry Research Division Archer Daniels Midland Company and Chair of the Uniform Methods Committee
More information3-MCPD esters in edible oils: analytical aspects
French Institute for Fats and Oïl 3-MCPD esters in edible oils: analytical aspects Florent JOFFRE, Hugues GRIFFON, Bénédicte SOULET and Florence LACOSTE 3-MCPD esters in oils: context Analysis of 3-MCPD:
More informationLimitation of Indirect Quantification for Glycidol Fatty Acid Ester in Edible Oils
Limitation of Indirect Quantification for Glycidol Fatty Acid Ester in Edible Oils Kao Corporation Global RD, Healthcare Food Labs. Indirect Quantification for GE (DGF Method) Combination of two different
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More information3-MCPD & 3-MCPD ester Food processed contaminants
-MCPD esters: Current Knowledge and Status Nuzul Amri Ibrahim Muhamad oddy amli aznim Arni Abdul azak Ainie Kuntom Malaysian Palm il Board Introduction utline -MCPD and -MCPD ester esearch by others Mechanism
More informationKEYWORDS ABSTRACT. 3-MCPD, Glycidol, edible oil, lab automation, ISO , AOCS Cd 29c-13, DGF C-VI 18 (10)
Fully Automated Determination of 3-MCPD and Glycidol in Edible Oils by GC/MS Based on the Commonly Used Methods ISO 18363-1, AOCS Cd 29c-13, and DGF C-VI 18 (10) Dominik Lucas, Andreas Hoffmann, Carlos
More informationThe Development and Application of the Automated Method for the Quantification of 3-MCPD-,2-MCPD-, and Glycidylesters in Edible Oils and Fats
The Development and Application of the Automated Method for the Quantification of 3-MCPD-,2-MCPD-, and Glycidylesters in Edible Oils and Fats Ralph Zwagerman, 21-06-2017, 3-MCPD Symposium, Berlin 1 Motivation
More informationLC/MS Method for Comprehensive Analysis of Plasma Lipids
Application Note omics LC/MS Method for Comprehensive Analysis of Plasma s Authors Tomas Cajka and Oliver Fiehn West Coast Metabolomics Center, University of California Davis, 451 Health Sciences Drive,
More informationDetermination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.
Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are
More informationFatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens
Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens Synopsis: This protocol describes the standard method for extracting and quantifying free fatty acids found in cells and media
More informationVitamin D3 and related compounds by ESI and APCI
Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate
More informationAnalytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)
Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is 2, 4, 5-T. 1. Instrument Liquid Chromatograph-tandem mass spectrometer (LC-MS/MS)
More informationAmphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS
Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 643 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia
More informationTime-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract.
Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium Application Natural Product Chemistry Authors Hideaki Uchida Agilent Technologies Japan, Ltd. Tokyo
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 18363-1 First edition 2015-08-15 Animal and vegetable fats and oils Determination of fatty-acid-bound chloropropanediols (MCPDs) and glycidol by GC/MS Part 1: Method using fast
More informationFast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )
Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Larry T. Taylor, 1 Jinchuan Yang, 2 and Giorgis Isaac 2 1 Department of
More informationMethods and Materials
Introduction Esterified and free forms of 2MCPD, 3MCPD and glycidol (Figure 1) are heatinduced contaminants found in various types of processed food. [1] Following ingestion, esterified forms of these
More informationMitigation of 3-monochloropropane-1,2-diol and glycidol esters in refined palm oil via modified refining process. Chin Ping TAN
Mitigation of 3-monochloropropane-1,2-diol and glycidol esters in refined palm oil via modified refining process Chin Ping TAN Contents Introduction Recent scientific opinion on MCPDE and GE issues (2016
More informationInterested in conducting your own webinar?
Interested in conducting your own webinar? Email webinars@bnpmedia.com An Automated System for the analysis of fatty acid methyl esters (FAME) in edible oils Institute for Food Safety and Health Illinois
More informationSTUDY OF 3-MCPD ESTERS AND GLYCIDYL ESTERS IN MALAYSIA
DGF Symposium on MCPD Esters and Glycidyl Esters, 20 21 June 2017, Berlin, Germany STUDY OF 3-MCPD ESTERS AND GLYCIDYL ESTERS IN MALAYSIA Raznim Arni Abd. Razak Product Development & Advisory Services
More informationIdentification of Steroids in Water by Ion Trap LC/MS/MS Application
Identification of Steroids in Water by Ion Trap LC/MS/MS Application Environmental Author Paul Zavitsanos and Christine Miller Agilent Technologies, Inc. Centerville Road Wilmington, DE 9- USA Abstract
More informationHigh-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System
High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System Application Note Food, Hydrocarbon Processing Authors Michael Woodman Agilent Technologies,
More informationAnalysis of MCPD- and Glycidyl- Esters in edible oils
Analysis of MCPD- and Glycidyl- Esters in edible oils IZMIR, TURKEY Dubois Mathieu Nestlé-Research-Center Quality and Safety Agenda 2 MCPD- and glycidyl-esters Esters of Mono-Chloro-Propane-Diol H ccurrence:
More informationPHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,
PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES DR. A. RAMESH, Ph.D, D.Sc., raamesh_a@yahoo.co.in 1 OBJECTIVES Determination of persistence and photolysis
More informationCannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D
More informationSample Preparation is Key
PLOS ONE DOI: 10.1371/journal.pone.0117232 February 6, 2015 Presented by Katie Gibbs Sample Preparation is Key Sample extraction and instrumental analysis methods are well documented in metabolomics. Understanding
More informationIndirect methods for the Analysis of MCPD and Glycidyl Esters: A Critical Overview
Indirect methods for the Analysis of MCPD and Glycidyl Esters: A Critical Overview Karel Hrncirik Unilever, The Netherlands ILSI EUROPE WORKSHOP ON MCPD AND GLYCIDYL ESTERS IN FOOD PRODUCTS 9-10 November
More informationCore E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley
Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley This protocol describes the extraction and direct measurement of cholesterol esters (CEs) and triacylglycerols
More informationApplication Note. Author. Abstract. Introduction. Food Safety
Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass
More informationApplication Note No. 301/2017
Application Note No. 301/2017 3-MCPD and glycidol in infant formula SpeedExtractor E-916, Multivapor P-6: Extraction of 3-MCPD and glycidyl-esters from infant formula www.buchi.com Quality in your hands
More informationMCPDs Esters & Glycidyl Esters: Validation of the Analytical Method and Occurrence in Vegetable Oils
MCPDs Esters & Glycidyl Esters: Validation of the Analytical Method and Occurrence in Vegetable Oils Florence LACOSTE, ITERG Recherche. Innovation. Qualité SISSG Workshop on 3-MCPD in Vegetable Oils UDINE,
More informationConcentrating Alpha-tocopherol from Oil Byproduct with Supercritical Methanol and CO 2
Concentrating Alpha-tocopherol from Oil Byproduct with Supercritical Methanol and CO 2 Tao Fang, Wahyudiono, Motonobu Goto *, Mitsuru Sasaki Department of Applied Chemistry and Biochemistry, Kumamoto University,
More informationA Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer
A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract
More informationQualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection
Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D
More informationValidation of Quantitative Method for Glycidol Fatty Acid Esters (GEs) in Edible Oils
102nd AOCS Annual Meeting & Expo Validation of Quantitative Method for Glycidol Fatty Acid Esters (GEs) in Edible Oils Hiroki Shiro, Naoki Kondo and Yoshinori Masukawa * Tochigi Research Labs Kao corporation
More informationMCPD and Glycidol in Edible Oils Post Refining Formation, Decomposition and Analysis SGS Germany GmbH J. Kuhlmann
MCPD and Glycidol in Edible Oils Post Refining Formation, Decomposition and Analysis SGS Germany GmbH J. Kuhlmann 1 Introduction, & Glycidol: Derivates of glycerol free : non-genotoxic carcinogen MCPD
More informationDetermination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry
Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent
More informationLC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column
Application Note Clinical Research LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell EC C8 Column Authors Rongjie Fu and Zhiming Zhang Agilent Technologies
More informationFatty acid esters of chloropropanols and glycidol in foods analysis and exposure
Fatty acid esters of chloropropanols and glycidol in foods analysis and exposure International Association for Food Protection European Symposium on Food Safety Warsaw 21-23 May 2012 Colin Crews 1 MCPD
More informationAnalysis of MCPD- and Glycidyl- Esters in edible oils
Analysis of MCPD- and Glycidyl- Esters in edible oils Dubois Mathieu Nestlé Research Center Lausanne Switzerland Extraction methods Direct vs Indirect method comparison Analytical standard management LC-MS
More informationA Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography
Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical
More informationKey Advantages of Comprehensive Cannabis Analysis
Comprehensive Cannabis Analysis: Pesticides, Aflatoxins, Terpenes, and High Linear Dynamic Range Potency from One Extract Using One Column and One Solvent System Robert Di Lorenzo 1, Diana Tran 2, KC Hyland
More informationAuthors. Abstract. Introduction. Environmental
Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationMethods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University
Methods in Mass Spectrometry Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University Sample Engineering Chemistry Biology Life Science Medicine Industry IDF / Police Sample
More informationKey Words: Brassica oleraceae, glucosinolate, liquid chromatography mass spectrometry, FNH-I-003
IDENTIFICATION OF MAJOR GLUCOSINOLATES IN BROCCOLI (Brassica oleracea var. italica) BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY (LC-MS) AND DETERMINATION OF ANTICANCER PROPERTIES OF BROCCOLI EXTRACTS Carlos
More informationAutomated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench
Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench Application Note Authors Rima Juskelis and Jack Cappozzo Institute for Food Safety and Health
More informationHigh Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column
High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column Application Note BioPharma Authors James Martosella, Phu Duong, and Alex Zhu Agilent Technologies, Inc. Abstract
More informationProficiency testing performance of Turkish laboratories on determination of relative composition of fatty acids in sunflower oil
ORIGINAL ARTICLE J. Chem. Metrol. 11:2 (2017) 40-45 Proficiency testing performance of Turkish laboratories on determination of relative composition of fatty acids in sunflower oil Hasibe Yilmaz 1*, Simay
More informationCarnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual
Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST
More informationAdvantages and disadvantages of different analytical techniques used to determine chloropropanols in food lipid matrices
Advantages and disadvantages of different analytical techniques used to determine chloropropanols in food lipid matrices Agnieszka Głowacz, Renata Jędrkieiwcz Gdańsk University of Technology Department
More informationUPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research
Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample
More informationToolbox for the Mitigation of 3-MCPD Esters and Glycidyl Esters in Food
Toolbox for the Mitigation of 3-MCPD Esters and Glycidyl Esters in Food Dr. Birgit Christall Bund für Lebensmittelrecht und Lebensmittelkunde e. V. (BLL) German Federation for Food Law and Food Science
More informationSummary Chapter 8 CHAPTER 8. Summary. Page 173
CHAPTER 8 Summary Page 173 Chapter 2: Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitative Estimation of PEG 400 and its Applications A rapid sensitive and selective MRM based method
More informationApplication Note. Abstract. Authors. Pharmaceutical
Analysis of xycodone and Its Metabolites-oroxycodone, xymorphone, and oroxymorphone in Plasma by LC/MS with an Agilent ZRBAX StableBond SB-C18 LC Column Application ote Pharmaceutical Authors Linda L.
More informationPhospholipid characterization by a TQ-MS data based identification scheme
P-CN1716E Phospholipid characterization by a TQ-MS data based identification scheme ASMS 2017 MP-406 Tsuyoshi Nakanishi 1, Masaki Yamada 1, Ningombam Sanjib Meitei 2, 3 1 Shimadzu Corporation, Kyoto, Japan,
More informationAnalysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS
Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS UCT Part Numbers ECQUEU7-MP Mylar pouch containing 4g MgSO4, 1g NaCl, 1g Na3Cit 2H2O and 0.5g Na2Cit 1.5H2O CUMPSC1875CB2CT 2mL dspe tube
More informationQuantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics
Quantitative Analysis of piates in Urine Using RRHT LC/MS/MS Application Forensics Authors Sheher Mohsin Agilent Technologies, Inc. 10 N. Martingale Rd., Suite 550 Schaumburg, IL 60173 USA Yanan Yang Agilent
More informationIon Suppression Minimized in LC/MSD
Welcome to our E-Seminar: Ion Suppression Minimized in LC/MSD Outline What is ion/signal suppression and why Approaches to minimize suppression Different ionization process ESI source design Fruit and
More informationRapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph
Application Note Food Rapid Analysis of 37 FAMEs with the Agilent 88 Gas Chromatograph Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd., Shanghai 131 P. R. China Abstract An Agilent 88 GC
More informationDetermination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety
Determination of Aflatoxins in Food by LC/MS/MS Application Food Safety Authors Masahiko Takino Agilent Technologies 9-1 Takakura-Cho Hachiouji-Shi, Tokyo Japan Toshitsugu Tanaka Kobe Institute of Health
More informationResidue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.
Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Aspartame This monograph was also published in: Compendium of Food Additive
More informationQuantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection
Application Note Food Testing, Metabolomics, Agricultural Chemistry, Environmental Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with
More informationDetection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole
Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent LC/MS Triple Quadrupole Application Food Safety Authors Yanyan Fang Agilent Technologies (Shanghai),
More informationThe challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample
The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample Presented by Michael Ye ExTech, 2014 sigma-aldrich.com/analytical 1 Agenda 1. Background; why and how analyze
More informationRapid Generation of Fatty Acid Methyl Ester Profiles using (Direct Analysis in Real Time) DART- Mass Spectrometry
Rapid Generation of Fatty Acid Methyl Ester Profiles using (Direct Analysis in Real Time) DART- Mass Spectrometry Brian Musselman, Jordan Krechmer, Tim Ng, and Joseph LaPoint IonSense, Inc. 999 Broadway
More informationLC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ
LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.
More informationThe HPLC Preparative Scale-Up of Soybean Phospholipids Application
The HPLC Preparative Scale-Up of Soybean Phospholipids Application Food and Flavors Authors Cliff Woodward and Ron Majors Agilent Technologies, Inc. 285 Centerville Road Wilmington, DE 1988-161 USA Abstract
More informationChromatography Vacuum Ultraviolet Spectroscopy
Application Note Differentiation and Determination Differentiation and Determination of Fatty Acid Methyl of Fatty Esters Acid by Gas Methyl Chromatography Esters by Vacuum Gas Ultraviolet Spectroscopy
More informationMaterials and Methods
J Am Oil Chem Soc (2017) 94:1323 1328 DOI 10.1007/s11746-017-3039-2 SHORT COMMUNICATION Identification of a TBHQ Interfering Peak in Crude Canola Oil Using AOCS Official Method Ce 6 86 and its Chromatographic
More informationMetabolomic fingerprinting of serum samples by direct infusion mass spectrometry
Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry Raúl González-Domínguez * Department of Chemistry, Faculty of Experimental Sciences. University of Huelva, Spain. * Corresponding
More informationDirect Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application
Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Food Safety Authors M. H. Blokland, P. W. Zoontjes, S. S. Sterk, and L. A. van Ginkel, National Institute of Public Health and
More informationDetermination of Amantadine Residues in Chicken by LCMS-8040
Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole
More informationCannabinoid Quantitation Using an Agilent 6430 LC/MS/MS
Cannabinoid Quantitation Using an Agilent 643 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia Department of Forensic Science
More informationREP18/CF-Appendix VI 1
REP18/CF-Appendix VI 1 APPENDIX VI PROPOSED DRAFT CODE OF PRACTICE FOR THE REDUCTION OF 3-MONOCHLOROPROPANE-1,2- DIOL ESTERS (3-MCPDE) AND GLYCIDYL ESTERS (GE) IN REFINED OILS AND FOOD PRODUCTS MADE WITH
More informationUsing Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.
Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationQuantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition
PO-CON1321E Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition ASMS 213 TP 71 Jie Xing 1, Yin Ling Chew*
More informationLC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods
LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods Application Note Food Testing & Agriculture Authors Nick Byrd and Danielle Sweeney Campden BRI Gloucestershire UK
More informationAutomated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS
Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,
More informationDIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD
DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD Kenichi TAKAICHI, Shuji SAITOH, Yoshio KUMOOKA, Noriko TSUNODA National Research Institute of Police Science, Chiba,
More informationQuality Considerations and Control Factors for Homebrewing Biodiesel. John Bush
Quality Considerations and Control Factors for Homebrewing Biodiesel John Bush John@boulderbiodiesel.com www.boulderbiodiesel.com Quality? Modern Diesel Engines are very sensitive to fuel quality issues.
More information[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector
Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Mark Benvenuti, Gareth Cleland, and Jennifer Burgess Waters Corporation, Milford, MA, USA
More informationPURPOSE: To synthesize soap from fat and lye. To observe the physical and chemical properties of soap.
FATS AND SAP: SAPNIFIATIN PURPSE: To synthesize soap from fat and lye. To observe the physical and chemical properties of soap. FATTY AIDS AND FATS: Fats and oils are mixtures of complex esters. Fat esters
More informationRapid and Robust Detection of THC and Its Metabolites in Blood
Rapid and Robust Detection of THC and Its Metabolites in Blood Application Note Forensics/Doping Control Author Stephan Baumann Agilent Technologies, Inc. Santa Clara CA 95051 USA Abstract A robust method
More informationQuantitative Method to measure Glycidol Fatty Acid Esters (GEs) in Edible Oils
101 st AOCS Annual Meeting & Expo Quantitative Method to measure Glycidol Fatty Acid Esters (GEs) in Edible Oils Hiroki Shiro* 1, Yoshinori Masukawa 1, Naoki Kondo 1 and Naoto Kudo 2 1 Tochigi Research
More informationFast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System
Fast deteration of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 126 Infinity Analytical SFC System Application Note Petrochemical Authors Maria Rambla Alegre, Melissa N. Dunkle,
More informationMatrix-induced Signal Enhancement of Propamocarb in LC-MS/MS
Observations concerning a compound a matrix a method other Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS Reported by: EURL-SRM Version 1 (last update: 24.10.2012) Brief description of problem/observation/solution:
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationAbstract. Introduction
A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue
More informationThis revision also necessitates a change in the table numbering in the test for Organic Impurities.
Methylphenidate Hydrochloride Extended-Release Tablets Type of Posting Notice of Intent to Revise Posting Date 27 Jul 2018 Targeted Official Date To Be Determined, Revision Bulletin Expert Committee Chemical
More information3-MCPD Esters in Edible Oils Current Knowledge
ILSI SEA Region 6th Asian Conference on Food and Nutrition Safety (Nov 2012) http://www.ilsi.org/sea_region/pages/vieweventdetails.aspx?webid=4d540914-eeb6-40e4-89eb-0b73ba3d76c1&listid=478be3cb-581b-4ba2-a280-8e00ccb26f9c&itemid=66
More informationAS Application Note 1602
Determination of the fatty acid composition in refined oils and fats by alkaline transesterification by the ASAN 1602 Status: February 2018 Page 1 / 12 Introduction Animal and vegetable fats play a key
More informationExtraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis
Application Note AN890 Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Page Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Prior to LC/MS-MS
More informationQuantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System
Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for
More informationAnalysis & occurrence of bound glycidol and MCPD in oil containing foods SGS Germany GmbH J. Kuhlmann
Analysis & occurrence of bound glycidol and MCPD in oil containing foods SGS Germany GmbH J. Kuhlmann 1 Introduction 2-MCPD, 3-MCPD & Glycidol: Glycerolderivates + HCl - H 2 O 3-MCPD (3-Chloropropane-1,2-diol)
More informationQuantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.
Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS Application Forensics Authors Neil Campbell, B. Sc. Forensic Science Laboratory Chemistry Centre (WA) 5 Hay Street
More informationAnalysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ
Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent
More information