Homogeneous assay for measuring low-density lipoprotein cholesterol in serum with triblock copolymer and -cyclodextrin sulfate

Size: px
Start display at page:

Download "Homogeneous assay for measuring low-density lipoprotein cholesterol in serum with triblock copolymer and -cyclodextrin sulfate"

Transcription

1 Clinical Chemistry 44: (1998) Lipids and Lipoproteins Homogeneous assay for measuring low-density lipoprotein cholesterol in serum with triblock copolymer and -cyclodextrin sulfate Hiroyuki Sugiuchi, 1 * Tetsumi Irie, 2 Yoshinori Uji, 3 Tomohiro Ueno, 1 Toshiko Chaen, 1 Kaneto Uekama, 2 and Hiroaki Okabe 3 We have developed a fully automated method for measuring LDL-cholesterol (LDL-C) in human serum without the need for prior separation, using a nonionic surfactant, polyoxyethylene polyoxypropylene block copolyether (POE-POP), and a sodium salt of sulfated cyclic maltohexaose, -cyclodextrin sulfate. Of the surfactants tested, POE-POP with a higher molecular mass of the POP block and a greater hydrophobicity reduced the reactivity of cholesterol in lipoprotein fractions; the reactivity in descending order was LDL >> VLDL > chylomicron HDL. Gel filtration chromatographic studies revealed that POE-POP removed lipids selectively from the LDL fraction and allowed them to participate in the cholesterol esterase cholesterol oxidase coupling reaction system. By contrast, -cyclodextrin sulfate reduced the reactivity of cholesterol, especially in chylomicrons and VLDL. A combination of POE-POP with -cyclodextrin sulfate provided the required selectivity for the determination of LDL-C in serum in the presence of magnesium ions and a small amount of dextran sulfate without precipitating lipoprotein aggregates. There was a good correlation between the results of LDL-C assayed by the proposed method and the beta-quantification reference method involving 161 sera with triglyceride concentrations ranging from 0.3 to 22.6 mmol/l. 1 Department of Central Laboratory, Kumamoto University Hospital, 1-1-1, Honjo, Kumamoto 860, Japan. 2 Faculty of Pharmaceutical Sciences, Kumamoto University, 5 1, Oehonmachi, Kumamoto 862, Japan. 3 Department of Laboratory Medicine, Kumamoto University, School of Medicine, 1-1-1, Honjo, Kumamoto 860, Japan. *Author for correspondence. Fax (81) ; sugiuchi@ gpo.kumamoto-u.ac.jp. Received August 28, 1997; revision accepted November 13, A positive correlation between the concentration of total cholesterol in serum and the incidence of coronary heart disease is the most consistent finding to emerge from epidemiological and clinical studies [1]. Because LDLcholesterol (LDL-C) accounts for approximately twothirds of the serum cholesterol and constitutes the primary atherogenic fraction of the circulating cholesterol, monitoring of LDL-C in serum provides the basis for the diagnosis and treatment of hyperlipemia [2]. 4 A wide variety of methods has been used for determining LDL-C in serum, including a precipitation-based method [3], electrophoresis [4], HPLC [5], sequential and density-gradient ultracentrifugation [6], Friedewald formula [7], and immunoseparation [8]. Of these, the Friedewald formula is the most commonly used approach in clinical laboratories; however, it is limited to specimens from fasting subjects and specimens with triglyceride concentrations 4.5 mmol/l [9]. Although beta-quantification by ultracentrifugation is the currently accepted reference method for measuring LDL-C in serum [10], it requires relatively large volumes of serum, long turnaround time, and is unsuitable for routine laboratory testing. Therefore, there is a great clinical need to develop a convenient and reliable method for measuring LDL-C in serum without resorting to any fractionation procedures. Interaction of surfactants with lipoproteins has been the focus of many studies [11, 12]. In general, for the determination of total cholesterol in serum, excess amounts of surfactants have been used for solubilizing all the lipoprotein cholesterol in a nonspecific manner and 4 Nonstandard abbreviations: LDL-C, HDL-C, LDL-, HDL-cholesterol; POE-POP, polyoxyethylene polyoxypropylene block copolyether; CHER, cholesterol esterase; CHOD, cholesterol oxidase; 4-AA, 4-aminoantipyrine; EMSE, N-ethyl-N-(3-methylphenyl)-N -succinyl ethylenediamine; MOPS, 3-(N-morpholino)propanesulfonic acid; Lp(a), lipoprotein(a); apo, apolipoprotein; and NCEP, National Cholesterol Education Program. 522

2 Clinical Chemistry 44, No. 3, allowing it to freely participate in the enzymatic reaction system. By contrast, an approach for the direct measurement of LDL-C in serum has been proposed on the basis of the sequential use of two surfactants that show differential selectivities towards lipoprotein fractions [13]. Recently, we established a direct method for measuring HDL-C in serum, with the combined use of polyethylene glycol-modified enzymes and -cyclodextrin sulfate [14, 15]. In these studies -cyclodextrin sulfate, which has a highly concentrated negative charge and possesses heparin-mimicking activity, was used to reduce the reactivity of cholesterol in chylomicron and VLDL fractions in the presence of magnesium ions, without the need for precipitation of these lipoprotein fractions. Furthermore, our preliminary studies have shown that a polyoxyethylene polyoxypropylene block polyether (POE-POP) reduced the reactivity of cholesterol, especially in HDL, suggesting that a combination of POE-POP with -cyclodextrin sulfate could provide the needed selectivity for the determination of LDL-C in serum. Building upon these studies, this paper deals with the potential application of POE-POP and -cyclodextrin sulfate in developing a novel direct assay for LDL-C in serum without prior fractionation. Materials and Methods materials Cholesterol esterase (EC ; CHER, 129 kda from Pseudomonas species) and cholesterol oxidase (EC ; CHOD, 35 kda from Pseudomonas species) were supplied by Kyowa Hakko Kogyo Co. 4-Aminoantipyrine (4-AA) and N-ethyl-N-(3-methylphenyl)-N -succinylethylenediamine (EMSE) were supplied by Kyowa Medex Co. All the surfactants used were commercially available. -Cyclodextrin was donated by Nihon Shokuhin Kako Co. The sodium salt of -cyclodextrin sulfate was prepared according to the nonregioselective method described previously [16]. The average degree of substitution of sulfate groups in -cyclodextrin sulfate was confirmed to be between (mean SD of five different lots) by fast-atom bombardment mass spectrometry and elemental analysis. Dextran sulfate (from dextran, with an average molecular mass of 500 kda) and 3-(N-morpholino)propanesulfonic acid (MOPS) were obtained from Sigma Chemical Co. and Dojin Chemical Co. respectively. Free and conjugated bilirubin dissolved in 30 g/l bovine serum albumin solution (ditaurobilirubin) were obtained from International Reagent Co. Immunoseparation reagent for the determination of LDL-C and latex agglutination reagent for the determination of lipoprotein(a) [Lp(a)] were obtained from Sigma Diagnostics and Daiichi Pure Chemicals Co. respectively. Human sera were obtained from healthy subjects 1 h after lunch, and the four major lipoprotein fractions [chylomicron, hydrated density (d) kg/l; VLDL, d kg/l; LDL, d kg/l; and HDL, d kg/l], isolated by ultracentrifugation according to the method of Hatch and Lees [6], were supplied by Health Care Technology Foundation. All other materials and solvents used were of analytical reagent grade. gel filtration analysis The separation of lipoprotein fractions was performed by HPLC (CCPA 8000, Tosoh) with a gel filtration column (TSK gel Lipopropak XL, Tosoh) according to the method of Kitamura et al. [17]. The individual lipoprotein fractions or serum samples were eluted with 2.6 mmol/l NaCl, ph 7.0, at a flow rate of 1.0 ml/min. The column effluent was collected at intervals of 30 s with a fraction collector (FRAC100, Pharmacia Biotech.). The concentrations of cholesterol and phospholipids in the fraction separated by HPLC were determined enzymatically (Determiner TC and PL, Kyowa Medex). The concentration of total proteins in the fractions separated by HPLC was determined by the micro BCA protein assay reagent kit (Pierce) and those of apolipoproteins A-I, A-II, B, C-II, C-III, and E by immunoturbidimetry (Daiichi Pure Chemicals Co.). There was no apparent contamination with any other proteins such as serum albumin. analytical procedure In the final formulation of reagents used for the determination, reagent 1 contained -cyclodextrin sulfate (0.5 mmol/l), dextran sulfate (0.5 g/l), MgCl 2 (2.0 mmol/l), and EMSE (1.4 mmol/l) in MOPS buffer (50 mmol/l, ph 6.75); reagent 2 consisted of CHER (1 ku/l), CHOD (3 ku/l), peroxidase (30 ku/l), 4-AA (2.5 mmol/l), and POE-POP (4 g/l) in MOPS buffer (50 mmol/l, ph 6.75). All the specimens were stored at 4 C and analyzed within 2 days after blood sampling. Four microliters of the serum sample was added to 300 L of reagent 1. The mixture was incubated at 37 C for 5 min before adding 100 L of reagent 2 and incubated for an additional 5 min. The chromophore formed in a coupled reaction with peroxidase was measured spectrophotometrically at 600 nm; alternatively, dual wavelength measurements [600 nm (main) and 700 nm (subsidiary)] were used, especially when assaying turbid or hemolyzed samples, to avoid any interference with the colorimetric assay. The concentration of LDL-C was calculated by using a serum-based calibrator (LDL-C, 2.77 mmol/l, Precinorm L; Boehringer Mannheim). The instruments used for the determination were a Hitachi 911 automated analyzer and a UV 160A spectrophotometer (Shimadzu). The results of LDL-C in serum assayed by beta-quantification method were obtained by Health Care Technology Foundation, performed according to the Lipid Research Clinic s protocol [18]. The immunoseparation reagent for the determination of LDL-C was used to remove HDL and VLDL from serum, leaving LDL in the filtrate, and was quantified with a standard cholesterol assay [8]. The concentration of triglycerides in serum was determined enzymatically (Determiner TG, Kyowa Medex) and the concentration of HDL-C in serum was

3 524 Sugiuchi et al.: Assay for LDL-cholesterol determined by a dextran sulfate phosphotungstate MgCl 2 precipitation method (Daiichi Pure Chemicals Co.) respectively. data analyses The contribution of various structural and physicochemical factors of surfactants to the selectivity towards LDL-C was statistically examined with multiple regression analysis [19]. Correlations and regression equations were calculated on a PC-9801UF personal computer (NEC), where a stepwise method was used and the validity of regression was judged by the F-test value ( 2.0). The data were analyzed statistically by one-way analysis of variance, with Duncan s multiple comparison test, and P values 0.01 were viewed as statistically significant. Table 1. Lipid composition of isolated lipoprotein fractions (mg/g protein). Lipid HDL LDL VLDL Chylomicron Total cholesterol Free cholesterol Triglycerides Phospholipids Results effect of surfactants on reactivity of lipoprotein cholesterol Compositions of lipids and proteins in the four major lipoprotein fractions used for this study are summarized in Table 1. The isolated lipoprotein fractions had the expected compositions, which are in good agreement with those of other compositional studies [20]. A total of 381 surfactants (24 cationic, 77 anionic, 249 nonionic, 6 amphoteric, and 25 other types) were surveyed with regard to the selectivity towards LDL-C. Fig. 1 shows the selectivity indices of surfactants (2 g/l) for LDL-C (SI LDL )in the presence of CHER (1 ku/l) and CHOD (3 ku/l). The SI LDL value is defined here as the product of the relative reactivity of cholesterol in the LDL fraction (the first term) and the LDL selectivity (the second term) according to the equation: SI LDL (R LDL /100) [(R LDL 3)/ R HDL R VLDL R Chylomicron )] (1) where R is the relative reactivity of cholesterol with the enzymes in each lipoprotein fraction, which is expressed as a percentage of the cholesterol reactivity in the presence of Triton X-100 (2 g/l), and the subscripts refer to each lipoprotein fraction, respectively. The LDL selectivity is defined as the ratio of the R LDL value to the sum of those for the other three lipoprotein fractions, where the R LDL value is multiplied by 3 to maintain the balance between the numerator (one term) and the denominator (three terms). Of the surfactants tested, some nonionic polymers showed greater selectivity towards LDL-C, giving a mean SI LDL value of 2.45 (Fig. 1). In particular, a series of POE-POP, as indicated by open circles in Fig. 1, were most superior with respect to LDL selectivity. POE-POP is an A-B-A-type triblock copolyether consisting of hydrophilic polyoxyethylene A blocks attached to a hydrophobic central polyoxypropylene B block. In this study we used 19 POE-POP with an average molecular mass ranging from 1100 to 6500 Da. The relative contribution of structural factors of the POE-POP to the selectivity towards LDL-C was examined by using multiple regression analysis. In an initial multiple regression equation, the variable criterion was the SI LDL value, and the explanatory variables were (a) the average molecular mass of POE-POP, (b) the molecular mass of the POP block in the POE-POP molecule (MM POP ), and (c) the Fig. 1. Selectivity indices of various surfactants (2 g/l) for LDL-C (SI LDL ) in the presence of CHER (1 ku/l) and CHOD (3 ku/l) in MOPS buffer (ph 7.0) at 37 C: E, SI LDL value for POE-POP; vertical bar represents the mean of the SI LDL values in each row.

4 Clinical Chemistry 44, No. 3, hydrophobicity index for POE-POP as indicated by the fractional molecular mass of the POP block in the POE- POP molecule (FM POP ), respectively. When a stepwise method was used and the validity of regression was judged by the F-test value ( 2.0), the first dependent variable was excluded from the equation and consequently the following equation was obtained: SI LDL ( )MM POP FM POP 5.10 (2) n 19, r 0.671, F 6.56) where the values in parentheses are the estimated standard error of the coefficient. Three-dimensional plots displaying the relation between the SI LDL value and the two predominant factors (MM POP and FM POP ) for POE- POP used are shown in Fig. 2. The partial correlation coefficients for the MM POP and FM POP were and 0.535, respectively. Because the magnitudes of the two coefficients are not significantly different, the two determinants may contribute equally to the selectivity of POE- POP towards LDL-C. On the basis of the above results, POE-POP with a MM POP value of 3850 Da and a FM POP value of 90%, giving a SI LDL value of 9.24, was selected as the most preferred reagent for the determination of LDL-C and used in the following studies. Figure 3 shows the relative reactivity of cholesterol in lipoprotein fractions as a function of POE-POP concentrations in the presence of CHER (1 ku/l) and CHOD (3 Fig. 2. Three-dimensional plot displaying the relation between the SI LDL value, MM POP, and FM POP for POE-POP in the presence of CHER (1 ku/l) and CHOD (3 ku/l) in MOPS buffer (ph 7.0) at 37 C. Fig. 3. Effects of POE-POP on relative reactivities of cholesterol in various lipoprotein fractions in the presence of CHER (1 ku/l) and CHOD (3 ku/l) in MOPS buffer (ph 7.0) at 37 C: E, HDL; F, LDL;, VLDL; Œ, chylomicron. ku/l). The relative reactivity of cholesterol in the lipoprotein fractions decreased with increasing concentrations of POE-POP, with the reactivity decreasing in the order: LDL VLDL chylomicron HDL. effects of poe-pop on gel filtration of lipoprotein fractions Insight into the mechanism by which POE-POP exhibits its selectivity towards LDL-C was gained by gel filtration chromatography. Fig. 4 shows the effect of POE-POP (4 g/l) on the elution pattern for the LDL fraction, as obtained by detecting cholesterol, phospholipids, and proteins in the effluent. In the presence of POE-POP, the first peak at 30 min contained predominantly apolipoprotein (apo) B, as determined by immunoturbidimetry, and cholesterol and phospholipids eluted later in a separate peak (Fig. 4B). The lipids isolated from the LDL particles would be solubilized in the mixed micelles with POE-POP, making them readily amenable to enzymatic reactions with CHER and CHOD. By contrast, when POE-POP at the same concentration as in Fig. 4 was added to the HDL fraction, it reduced the elution volume of the HDL fraction, with only a small change in the protein/lipid composition (Fig. 5). In fact, the protein fraction shown in Fig. 5B contained apo A-I and apo A-II at a molar ratio of 5:1, which is consistent with the expected protein concentrations for the intact HDL fraction. This suggests that the POE-POP varies the density or surface charge of the HDL particles and (or) induces the aggregation of HDL to macroparticles. If such is the case, the modified HDL particles should be resistant to the enzymatic reactions, eventually leading to reduced reactivity of cholesterol in that lipoprotein fraction. In the case of chylomicron and VLDL, the addition of POE-POP

5 526 Sugiuchi et al.: Assay for LDL-cholesterol Fig. 4. Elution patterns of the LDL fraction in the absence and presence of POE-POP (4 g/l), as monitored by cholesterol (E), phospholipids (F), and proteins ( ): A, without POE-POP; B, with POE-POP. to those lipoprotein fractions caused no remarkable separation of proteins and lipids (data not shown). The above results clearly indicate that the POE-POP-mediated selectivity towards LDL-C can be ascribable to selective solubilization of cholesterol in the LDL fraction, thus allowing it to participate in the enzymatic reactions. combination effects of poe-pop with -cyclodextrin sulfate The reactivity of cholesterol in the VLDL fraction persisted with the sole use of POE-POP at concentrations up to 4 g/l, as shown in Fig. 3. For accomplishing the direct determination of LDL-C, the reactivities of cholesterol in all the lipoprotein fractions except for LDL must be completely abolished. For this purpose, we used -cyclodextrin sulfate in combination with POE-POP. Our previous studies have shown that -cyclodextrin sulfate, having a highly concentrated negative charge and possessing heparin-like activity, reduces the reactivity of cholesterol, especially in chylomicrons and VLDL in the presence of magnesium ions, without precipitating those lipoprotein Fig. 5. Elution patterns of the HDL fraction in the absence and presence of POE-POP (4 g/l), as monitored by cholesterol (E), phospholipids (F), and proteins ( ): A, without POE-POP; B, with POE-POP. aggregates. Recent studies have demonstrated that cyclodextrin sulfates exhibit threshold behavior in their heparin-mimicking activities; the introduction of 2 sulfate groups per glucose unit is adequate [21]. Therefore, in this study we prepared -cyclodextrin sulfate with a degree of sulfation of 12, which corresponds to an average substitution of 2 hydroxyl groups per glucose unit. Fig. 6 shows the relative reactivity of cholesterol in lipoprotein fractions as a function of magnesium ions in the presence of the POE-POP (4 g/l), -cyclodextrin sulfate (0.5 mmol/l), dextran sulfate (0.5 g/l), CHER (1 ku/l), and CHOD (3 ku/l). The relative reactivity of cholesterol in the lipoprotein fractions decreased with increasing concentrations of POE-POP, with reactivity decreasing in the order: LDL VLDL chylomicron HDL. Finally, the residual reactivities with fractions other than LDL were completely abolished by adding magnesium ions at concentrations 2 mmol/l.

6 Clinical Chemistry 44, No. 3, Fig. 6. Effects of MgCl 2 on relative reactivities of cholesterol in various lipoprotein fractions in the presence of POE-POP (4 g/l), -cyclodextrin sulfate (0.5 mmol/l), dextran sulfate (0.5 g/l), CHER (1 ku/l), and CHOD (3 ku/l) in MOPS buffer (ph 7.0) at 37 C: E, HDL; F, LDL;, VLDL; Œ, chylomicron. time course of enzymatic reaction Figure 7 shows changes with time in absorbance at 550 nm during the reaction of LDL-C, as determined at intervals of 20 s for 10 min, with the four lipoprotein fractions and the serum samples (diluted five times serially with 155 mmol/l NaCl solution) from a patient with hyperlipemia (total cholesterol mmol/l, triglycerides 2.82 mmol/l, HDL-C 0.78 mmol/l). Only LDL-C from both the lipoprotein fractions and the serum sample exhibited reactivity, reaching a plateau within 5 min after the addition of reagent 2. calibration curve and linearity When calibration for the LDL-C assay was performed with control serum Precinorm L (LDL-C, 2.77 mmol/l, Boehringer Mannheim) for lipid determination, a straight line passing through the origin was obtained, and the calibration was stable during the 1-month period, with absorbance readings varying within 1%. The LDL fraction (LDL-C, 15.5 mmol/l) isolated by ultracentrifugation was diluted with 155 mmol/l NaCl solution, and linearity of the method was investigated. As shown in Fig. 8, good linearity was obtained with the serially diluted fractions of LDL-C solutions up to 15.5 mmol/l. The minimum detectable concentration was mmol/l. When serum samples from patients with hyperlipemia (triglycerides mmol/l, total cholesterol mmol/l) were serially diluted with 155 mmol/l NaCl solution and used for assessment of the linearity, good linearity was obtained, suggesting that the influence of cholesterol derived from VLDL and chylomicrons in sera of patients with hyperlipemia was negligible or nonexistent. Fig. 7. Changes with time in absorbance at 550 nm during the reaction of cholesterol in various lipoprotein fractions (A) and in the serum samples (diluted five times serially with 155 mmol/l NaCl solution) from a patient with hyperlipemia (total cholesterol 11.1 mmol/l, triglycerides 2.8 mmol/l, HDL-C 0.8 mmol/l) (B): (A) E, HDL; F, LDL;, VLDL; Œ, chylomicron;, 155 mmol/l NaCl solution; (B) E, 1/5; F, 2/5;, 3/5; Œ, 4/5;, 5/5. imprecision and recovery tests Repeatability and reproducibility of the method with three different serum samples are shown in Table 2. For run-to-run precision studies the specimens were stored at 80 C and the proposed method indeed worked with the frozen sera. In all three cases, the values obtained were within 4% of the target values as recommended by the National Cholesterol Education Program (NCEP) [22]. For the recovery test, 100 L of the LDL fraction (LDL-C, 5.82 mmol/l) isolated by ultracentrifugation was added to 400 L of the pooled serum (LDL-C, 1.34, 2.72, and 3.54 mmol/l) and the assay was performed with the reagent. The mean SD recovery was 101.1% 3.8% with nine specimens, and ranged between 97% and 105%. interfering substances Addition of conjugated bilirubin at final concentrations up to 0.68 mmol/l (0.14, 0.27, 0.41, 0.55, and 0.68

7 528 Sugiuchi et al.: Assay for LDL-cholesterol Fig. 8. Linearity of direct method for assaying LDL-C by using LDL fraction and serum samples (diluted five times serially with 155 mmol/l NaCl solution) from patients with hyperlipemia (triglycerides mmol/l, total cholesterol mmol/l): E, LDL fraction (triglycerides 1.4 mmol/l); F, triglycerides 4.4 mmol/l and total cholesterol 14.2 mmol/l;, triglycerides 9.6 mmol/l and total cholesterol 7.2 mmol/l; Œ, triglycerides 17.6 mmol/l and total cholesterol 6.7 mmol/l;, triglycerides 13.1 mmol/l and total cholesterol 4.7 mmol/l. Clinic s Program) with serum samples from healthy volunteers (n 86), patients with hyperlipemia (triglycerides 4.5 mmol/l, n 41), and from patients with hyperlipemia (triglycerides 4.5 mmol/l, n 34). For serum samples from these three populations, there was a high degree of correlation between the results of the proposed method and those of the beta-quantification method, with r or better. As shown in Fig. 9, the mean percentage bias of standard deviation for LDL-C determined by the proposed method in comparison with the beta-quantification method was 0.73% 5.78% ( mmol/l) with serum samples from healthy volunteers, showing 1.01% 5.27% ( mmol/l), and those from patients with hyperlipemia, showing no significant difference (P 0.5). There was no increase in the percentage bias, even when the concentrations of triglycerides and HDL-C were high. Correlations between the proposed method and other methods (Friedewald formula, immunoseparation, and HPLC method) are sum- mmol/l) to the pooled serum produced a slightly negative error of up to 10% in the assay result. No adverse effect was observed when free bilirubin (up to 0.68 mmol/l), ascorbic acid (up to 2.84 mmol/l), hemoglobin (up to 5 g/l), Intralipos (up to 10 g/l, The Green Cross Co.), EDTA-2Na (up to 0.27 mmol/l), or citrate (up to 0.34 mmol/l) was included during the measurement of LDL-C with this assay. However, when citrate at a final concentration of 12.9 mmol/l was used as an anticoagulant for whole blood, it produced a slightly negative error of 7.8% in the assay result. comparison with other methods The proposed method was compared with ultracentrifugation (beta-quantification method of the Lipid Research Table 2. Precision of the proposed method for measuring LDL-C in serum. Serum Mean, mmol/l SD, mmol/l CV, % I II III Run-to-run precision b I II III a Twenty aliquots of each serum were assayed simultaneously. b The three sera were assayed in duplicate for 10 days with a single reagent lot. Fig. 9. Biases between direct method and beta-quantification method for assaying LDL-C with serum samples from healthy volunteers (n 86), patients with hyperlipemia (triglycerides 4.5 mmol/l, n 41), and from patients with hyperlipemia (triglycerides 4.5 mmol/l, n 34), as associated with LDL-C (beta-quantification method), triglycerides, and HDL-C concentrations: F, sera from healthy volunteers and patients with hyperlipemia (triglycerides 4.5 mmol/l); E, sera from patients with hyperlipemia (triglycerides 4.5 mmol/l).

8 Clinical Chemistry 44, No. 3, marized in Table 3. In the serum samples from healthy volunteers, the results obtained by the proposed method were well correlated with other methods (r ), but in those from patients with hyperlipemia (triglycerides 4.5 mmol/l), the correlation coefficient increased in the order: Friedewald formula immunoseparation HPLC beta-quantification method. The LDL fraction used in this study is heterogeneous, and contains remnant particles of IDL (d kg/l) and Lp(a) (d kg/l). The proposed method for measuring LDL-C would actually include the contribution of IDL and Lp(a), since there was a good correlation between the results of LDL-C assayed by the proposed method and the beta-quantification method. This estimate is supported by the fact that 77.6% 3.3% of total cholesterol ( mmol/l) in the IDL fraction isolated by ultracentrifugation responded to the proposed method. On the other hand, no direct evidence is available to clarify whether the proposed method would include particles of Lp(a), because of the difficulty in isolating the Lp(a) from the LDL and HDL fractions by ultracentrifugation. Nevertheless, there was no increase in the percentage bias for LDL-C determined by the proposed method in comparison with the beta-quantification method as the concentration of Lp(a) increased. This indicates that the proposed method would also include Lp(a). Discussion Many of the current techniques used for the determination of LDL-C in serum are cumbersome, time consuming, and require specialized instrumentation, which limits their use in the clinical laboratory. The NCEP Working Group on Lipoprotein Measurement has been developing recommendations for LDL-C measurement capable of quantifying LDL-C directly; it should not be based on calculation of difference between two or more measured values [22]. We established a direct method for determining the concentration of LDL-C in serum in a convenient format with the combined use of POE-POP and -cyclodextrin sulfate. Only a very small sample volume (4 L) is needed for this method, without the need for isolation of LDL. LDL-C can be determined in a short time (10 min) by this homogeneous method, which can be easily automated. The strategy used for direct measurement of LDL-C in serum is based on the cooperative actions of POE-POP as a quencher for HDL-C and -cyclodextrin sulfate as a quencher for chylomicrons and VLDL-C. This is distinctly different from the approach used for the homogeneous assay for the direct measurement of LDL-C in serum described previously [13], in which one surfactant selectively hydrolyzes chylomicrons, VLDL, and HDL in a non-color-forming reaction, and then another surfactant hydrolyzes only LDL for color development. Previously, poloxamers including POE-POP have been successfully utilized as surface modifiers for improving the stability of latex particles [23] and as vehicles for transdermal drug delivery [24]. In this study, POE-POP showed limited specificity towards LDL-C, solubilizing it into mixed micelles and thus allowing it to participate in the enzymatic reaction. Some surfactants can be used to isolate apo B and lipids from the LDL fraction [25, 26], but show no selectivity towards LDL-C under the present conditions. Although the mechanism that confers such LDL selectivity to POE-POP is not clear, it is possible that the surfactant may be able to recognize differences in hydrated density, net charge, or size of the various lipoprotein fractions. As shown in Fig. 3, the higher the molecular mass of the POP block and hydrophobicity, the Table 3. Correlations between the proposed LDL assay and other methods with sera from healthy volunteers (I), patients with hyperlipemia (triglycerides <4.5 mmol/l) (II), and with hyperlipemia (triglycerides >4.5 mmol/l) (III). a Method Group Slope (a) y-intercept (b) r n Mean SD, mmol/l Proposed method I II b III Friedewald formula I II b III b,c Immunoseparation I II b III HPLC I II b III Beta quantification I II b III a In the form y ax b; y the proposed method; x other method. b P 0.01 vs group I, c P 0.01 vs the proposed method.

9 530 Sugiuchi et al.: Assay for LDL-cholesterol greater the selectivity towards LDL-C. Apo A-I and apo A-II in the HDL particle are known to be water soluble, whereas apo B in the LDL fraction has an extremely large molecular mass of 540 kda and is highly hydrophobic in nature [27]. Apo B and its aggregates isolated from the LDL particle by POE-POP may be solubilized in the complex form with the surfactant and have an apparent molecular mass of kda, as judged by the elution volume in the gel filtration. In such a complex, the peripheral hydrophilic POE blocks should point freely in solution, whereas the central hydrophobic POP block anchors the surfactant to the hydrophobic surface of the apolipoprotein. On the other hand, the inability of POE- POP to remove apo A-I and apo A-II from the HDL particle may be explained in part by the hydrophilicity of those apolipoproteins and the physical size of the POE- POP micelles, which may not allow them to penetrate the interior of the HDL particle and thus may not solubilize the lipids. The heparin-like activity of -cyclodextrin sulfate was utilized to reduce the reactivity of cholesterol in chylomicrons and VLDL in a manner similar to that reported previously [14, 15]. -Cyclodextrin sulfate has an average molecular mass of 2194 Da, which is 100 times smaller than those of the polyanions used in precipitation-based methods. Furthermore, the charge density of -cyclodextrin sulfate is higher than those of the polyanions because of spatial constraints imposed on the sulfates by the hexasaccharide ring structure. In the presence of magnesium ions, -cyclodextrin sulfate may form water-soluble and submicron-sized complexes with those lipoproteins with a low protein/lipid ratio, which are resistant to the enzymatic reactions. In fact, there was no noticeable visible precipitation during the measurement of LDL-C with this assay. By contrast, when dextran sulfate was included instead of -cyclodextrin sulfate, it increased the turbidity of the reaction mixture to such an extent that it interfered with the determination of LDL-C in serum. The proposed method for measuring LDL-C would include the contribution of IDL and Lp(a), as the Friedewald equation or beta-quantification method does. Because all of the particles of this wide-density LDL population are atherogenic, the proposed method might be a more sensitive indicator of risk for premature coronary artery diseases than a method that has the limited specificity for the narrow-density LDL population. In conclusion, the homogeneous assay described here is simple and reliable for measuring LDL-C in serum without prior fractionation and should prove to be quite useful in the routine clinical laboratory. We express our thanks to Masao Umemoto of the Health Care Technology Foundation, Tokyo, Japan, for supplying the samples of the four lipoprotein classes used in this study. References 1. Kannel WB, Castelli WP, Gordon T. Cholesterol in the prediction of atherosclerotic disease: new perspectives based on the Framingham Study. Ann Intern Med 1979;90: Gordon T, Kannel WB, Castelli WP, Dawber TR. Lipoproteins, cardiovascular disease and death; the Framingham study. Arch Intern Med 1981;141: Wieland H, Seidel D. A simple method for precipitation of low density lipoproteins. J Lipid Res 1983;24: Nauck M, Winkler K, März W, Wieland H. Quantitative determination of high-, low-, and very-low-density lipoproteins and lipoprotein(a) by agarose gel electrophoresis and enzymatic cholesterol staining. Clin Chem 1995;41: Carrol RM, Rudel LL. Lipoprotein separation and low density lipoprotein molecular weight determination using high performance gel-filtration chromatography. J Lipid Res 1983;24: Hatch FT, Lees RS. Practical methods for plasma lipoprotein analysis. Adv Lipid Res 1968;6: Friedewald WT, Levy RI, Fredrickson DS. Estimation of the concentration of low-density lipoprotein cholesterol in plasma, without use of the preparative ultracentrifuge. Clin Chem 1972;18: Pisani T, Gebski CP, Leary ET, Warnick GR, Ollington JF. Accurate direct determination of low-density lipoprotein cholesterol using an immunoseparation reagent and enzymatic cholesterol assay. Arch Pathol Lab Med 1995;119: Warnick GR, Knopp RH, Fitzpatrick V, Bronson L. Estimating low-density lipoprotein cholesterol by the Friedewald equation is adequate for classifying patients on the basis of nationally recommended cutpoints. Clin Chem 1990;36: Belcher JD, McNamara JR, Grinstead GF, Rifai N, Warnick GR, Bachorik P, Frantz I. Measurement of low density lipoprotein cholesterol concentration. In: Rifai N, Warnick GR, eds. Methods for clinical laboratory measurement of lipid and lipoprotein risk factors. Washington, DC: AACC, 1991: Ikai A. Extraction of apo B cluster from human low density lipoprotein with Tween 80. J Biochem 1980;88: Hino K, Nakayama M, Nakanishi K, Manabe M. A new method for the homogeneous assay of serum HDL-cholesterol [Abstract]. Clin Chem 1996;42: Halloran P, Pisani T, Long S. A homogeneous assay for the direct measurement of LDL-cholesterol in serum [Abstract]. Clin Chem 1987;43: Sugiuchi H, Uji Y, Okabe H, Irie T, Uekama K. Differential effects of modified cyclodextrins on serum lipoprotein. Application to direct measurement of high-density lipoprotein in serum. In: Osa T, ed. Proceedings of the 7th International Symposium on Cyclodextrins. Tokyo: Komiyama Printing Co., 1994: Sugiuchi H, Uji Y, Okabe H, Irie T, Uekama K, Kayahara N, Miyauchi K. Direct measurement of high-density lipoprotein in serum with polyethylene glycol-modified enzymes and sulfated -cycrodextrin. Clin Chem 1995;41: Folkman J, Weisz PB, Joullie MM, Li WW, Ewing WR. Control of angiogenesis with synthetic heparin substitutes. Science 1989; 243: Kitamura T, Ito S, Moriyama H, Kato Y, Sasamoto K, Okazaki M. Quantitative analysis of serum lipoproteins (CM, VLDL, LDL and HDL) by high-performance gel filtration chromatography. Chromatography 1996;17: Manual of laboratory operation: Lipid Research Clinics Program. Vol. 1, DHEW publication no. (NIH) Washington, DC: Department of Health, Education, and Welfare, Tanaka U, Tarumi T, Wakimoto K. Handbook of statistical analysis by personal computer II: multivariate analysis. Tokyo: Kyoritsu, 1984:16 37.

10 Clinical Chemistry 44, No. 3, Havel RI, Kane JP. Introduction: structure and metabolism of plasma lipoproteins. In: Scriver CR, Beaudet AL, Sly WS, et al., eds. The metabolic and molecular bases of inherited disease, 7th ed. New York: McGraw Hill, 1995: Burke CJ, Volkin DB, Mach H, Middaugh CR. Effect of polyanions on the unofolding of acidic fibrobrast growth factor. Biochemistry 1993;32: Bachorik PS, Ross JW. National Cholesterol Education Program recommendations for measurement of low density lipoprotein cholesterol: executive summary. Clin Chem 1995;41: Juhász J, Lenaerts V, Bellemare M, Pimienta C, Ong H. Stability and adsorption to polymeric surfaces of rat ANF in poloxamer 407 solutions. Int J Pharm 1991;77: Cappel MJ, Kreuter J. Effect of nonionic surfactants on transdermal drug delivery: II. Poloxamer and poloxamine surfactants. Int J Pharm 1991;69: Helenius A, Simons K. Removal of lipids from human plasma low-density lipoprotein by detergents. Biochemistry 1971;10: Patterson BW, Kilgore LL, Chun PW, Fisher WR. Structural studies on apolipoprotein B: controllable heterogeneity of the complex formed with the surfactant, Triton X-100. J Lipid Res 1984;25: Chan L. Apolipoprotein B, the major protein component of triglyceride-rich and low density lipoproteins. J Biol Chem 1992;267:

ARTICLE. Utility of Direct Measurement of Low-Density Lipoprotein Cholesterol in Dyslipidemic Pediatric Patients

ARTICLE. Utility of Direct Measurement of Low-Density Lipoprotein Cholesterol in Dyslipidemic Pediatric Patients ARTICLE Utility of Direct Measurement of Low-Density Lipoprotein Cholesterol in Dyslipidemic Pediatric Patients Baruch S. Ticho, MD, PhD; Ellis J. Neufeld, MD, PhD; Jane W. Newburger, MD, MPH; Neil Harris,

More information

1 Introduction Imprecision Within-run imprecision, results Day-to-day imprecision, results... 2

1 Introduction Imprecision Within-run imprecision, results Day-to-day imprecision, results... 2 Design Verification liquicolor 1 Introduction... 2 2 Imprecision... 2 2.1 Within-run imprecision, results... 2 2.2 Day-to-day imprecision, results... 2 3 Linearity and Detection Limit... 2 3.1 Linearity...

More information

Comparison of two assays for measuring LDL cholesterol

Comparison of two assays for measuring LDL cholesterol Clinical Chemistry 43:6 1040 1047 (1997) Lipids and Lipoproteins Comparison of two assays for measuring LDL cholesterol Anirban Maitra, Shaina V. Hirany, and Ishwarlal Jialal* The purpose of this study

More information

Direct Measurement of High-Density Lipoprotein Cholesterol in Serum with Polyethylene Glycol-Mod ified Enzymes and Sulfated a-cyclodextrin

Direct Measurement of High-Density Lipoprotein Cholesterol in Serum with Polyethylene Glycol-Mod ified Enzymes and Sulfated a-cyclodextrin CLIN. CHEM. 41/5, 717-723 (1995) #{149} Lipids and Lipoproteins Direct Measurement of High-Density Lipoprotein Cholesterol in Serum with Polyethylene Glycol-Mod ified Enzymes and Sulfated a-cyclodextrin

More information

Separation of HDL Particles by Immunoprecipitation

Separation of HDL Particles by Immunoprecipitation Sun Diagnostics, LLC Separation of HDL Particles by Immunoprecipitation Rae-Anne Nguyen and John H. Contois 13 Introduction We all know that HDL cholesterol concentration is inversely associated with coronary

More information

New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol

New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol Clinical Chemistry 44:7 1443 1451 (1998) Lipids and Lipoproteins New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol

More information

Evaluation of Calculated Low-Density Lipoprotein Against a Direct Assay

Evaluation of Calculated Low-Density Lipoprotein Against a Direct Assay Evaluation of Calculated Low-Density Lipoprotein Against a Direct Assay Navapun Charuruks MD*, Anna Milintagas BSc** * Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University **

More information

Comparison of a Homogeneous Assay With a Precipitation Method for the Measurement of HDL Cholesterol in Diabetic Patients

Comparison of a Homogeneous Assay With a Precipitation Method for the Measurement of HDL Cholesterol in Diabetic Patients Clinical Care/Education/Nutrition O R I G I N A L A R T I C L E Comparison of a Homogeneous Assay With a Precipitation Method for the Measurement of HDL Cholesterol in Diabetic Patients TONNY JENSEN, MD

More information

1. Reagent Store at 2-8 ºC.

1. Reagent Store at 2-8 ºC. LDL Insert Ref.:146 Intended use. System for direct quantitative determination of low density lipoprotein (LDL) in serum or plasma samples. Professional use. [For in vitro diagnostic use.] Test principle.

More information

Lipid Profile Analysis of Aircrew

Lipid Profile Analysis of Aircrew Original Article Lipid Profile Analysis of Aircrew Sampath S *, Richa + ABSTRACT Most laboratories including all our Armed Forces Centers, estimate Low Density Lipoproteins Cholestorol (LDL-C) levels with

More information

Evaluation of a Rapid Homogeneous Method for Direct Measurement of High-Density Lipoprotein Cholesterol

Evaluation of a Rapid Homogeneous Method for Direct Measurement of High-Density Lipoprotein Cholesterol Clinical Chemistry / ORIGINAL ARTICLE Evaluation of a Rapid Homogeneous Method for Direct Measurement of High-Density Lipoprotein Cholesterol R. Scott Hubbard, MD,1 Shaina V. Hirany, MS,2 Sridevi Devaraj,

More information

Katsuyuki Nakajima, PhD. Member of JCCLS International Committee

Katsuyuki Nakajima, PhD. Member of JCCLS International Committee Katsuyuki Nakajima, PhD Member of JCCLS International Committee Visiting Professor and Scientist Tufts University, Boston, MA & Framingham Offspring Study, Framingham, MA August 20 th, 2011, Tokyo Framingham

More information

Serum low-density lipoprotein and high-density lipoprotein cholesterol. determined by ultracentrifugation and high-performance liquid

Serum low-density lipoprotein and high-density lipoprotein cholesterol. determined by ultracentrifugation and high-performance liquid Serum low-density lipoprotein and high-density lipoprotein cholesterol determined by ultracentrifugation and high-performance liquid chromatography Jun Dong, 1 Hanbang Guo, 1 Ruiyue Yang, 1 Hongxia Li,

More information

LDL LD. 01 English - Ref.: 129. Ref.:129. Insert. Intended use. Methodology. Reagents. Test principle. Summary. Precautions and warnings

LDL LD. 01 English - Ref.: 129. Ref.:129. Insert. Intended use. Methodology. Reagents. Test principle. Summary. Precautions and warnings LDL LD Insert Ref.:129 Intended use. System for direct quantitative determination of low density lipoprotein (LDL) in serum or plasma samples. [For in vitro diagnostic use.] Test principle. The method

More information

Shinichi Usui, 1 Masakazu Nakamura, 2 Kazuhiro Jitsukata, 3 Masayuki Nara, 4 Seijin Hosaki, 1 and Mitsuyo Okazaki 4*

Shinichi Usui, 1 Masakazu Nakamura, 2 Kazuhiro Jitsukata, 3 Masayuki Nara, 4 Seijin Hosaki, 1 and Mitsuyo Okazaki 4* Clinical Chemistry 46:1 63 72 (2000) Lipids, Lipoproteins, and Cardiovascular Risk Factors Assessment of Between-Instrument Variations in a HPLC Method for Serum Lipoproteins and Its Traceability to Reference

More information

Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase

Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase Clinical Chemistry 43:10 1932 1936 (1997) Automation and Analytical Techniques Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase Yoshitaka Morishita, 1 * Kiyoshi Nakane,

More information

3 Linearity and Detection Limit Linearity Detection limit... 4

3 Linearity and Detection Limit Linearity Detection limit... 4 Design Verification liquicolor 1 Introduction... 2 2 Imprecision, Reproducibility... 2 2.1 Data from internal study... 2 2.2 Date from external study (Cholesterol Reference Method Laboratory Network)...

More information

Serum LDL- and HDL-cholesterol determined by ultracentrifugation and HPLC

Serum LDL- and HDL-cholesterol determined by ultracentrifugation and HPLC Serum LDL- and HDL-cholesterol determined by ultracentrifugation and HPLC methods Jun Dong, * Hanbang Guo, * Ruiyue Yang, * Hongxia Li, * Shu Wang, * Jiangtao Zhang, and Wenxiang Chen 1, *, Institute of

More information

LDLC3. English System information For cobas c 311/501 analyzers:

LDLC3. English System information For cobas c 311/501 analyzers: Order information Analyzer(s) on which cobas c pack(s) can be used 07005717 190 LDL Cholesterol Gen.3 (200 tests) System ID 07 7565 7 Roche/Hitachi cobas c 311, cobas c 501/502 12172623 122 Calibrator

More information

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%) cobas b system - performance evaluation Study report from a multicenter evaluation of the new cobas b system for the measurement of HbAc and lipid panel Introduction The new cobas b system provides a point-of-care

More information

PLASMA LIPOPROTEINS AND LIPIDS DETERMINATION OF PLASMA CHOLESTEROL AND TRIGLICERIDE LEVEL

PLASMA LIPOPROTEINS AND LIPIDS DETERMINATION OF PLASMA CHOLESTEROL AND TRIGLICERIDE LEVEL PLASMA LIPOPROTEINS AND LIPIDS DETERMINATION OF PLASMA CHOLESTEROL AND TRIGLICERIDE LEVEL Lipids are characterized by low polarity and limited solubility in water. Their plasma concentration is about 500-600

More information

The Adiponectin Turbidimetric Immunoassay Reagent Kit

The Adiponectin Turbidimetric Immunoassay Reagent Kit The Adiponectin Turbidimetric Immunoassay Reagent Kit Catalogue number: 51010 For the quantitative determination of Adiponectin in human serum and plasma This package insert must be read in its entirety

More information

JLR Papers In Press. Published on October 16, 2003 as Manuscript D JLR200

JLR Papers In Press. Published on October 16, 2003 as Manuscript D JLR200 JLR Papers In Press. Published on October 16, 2003 as Manuscript D300024-JLR200 A method of direct measurement for the enzymatic determination of cholesterol esters Toshimi Mizoguchi 1, Toshiyuki Edano,

More information

Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer

Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer Biochemistry & Fundamental Reference Laboratory, Yokohama Our Head Office and Biochemistry Reference Laboratory moved to Yokohama with aims to have further development on the 21 st September, 2018. [Reference

More information

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date AU US Instructions For Use 2018 Beckman Coulter, Inc. All rights reserved. TRIG TRIGLYCERIDE OSR60118 4 x 20 ml R1, 4 x 5 ml R2 OSR61118 4 x 50 ml R1, 4 x 12.5 ml R2 OSR66118 4 x 173 ml R1, 4 x 48 ml R2

More information

LDL . (LDL) Downloaded from ijdld.tums.ac.ir at 12:38 IRST on Friday February 1st 2019 LDL LDL NCEP-ATP-III (LDL) :

LDL . (LDL) Downloaded from ijdld.tums.ac.ir at 12:38 IRST on Friday February 1st 2019 LDL LDL NCEP-ATP-III (LDL) : 197-207 (2 ) 10 1389 -. 2 1 1* :.. 352 :... (TG). (). -.(r= 0/95) :. TG. NCEP-ATP-III. :. () : -1-2 1593748711 : ronakn2000@yahoo.com : 88942661-5 09124135284 ... : 198.[4]. 1990 -. C.[4]. NCEP.[4]...

More information

Evaluation of five methods for determining low-density lipoprotein cholesterol (LDL-C) in hemodialysis patients

Evaluation of five methods for determining low-density lipoprotein cholesterol (LDL-C) in hemodialysis patients Clinical Biochemistry 34 (2001) 593 602 Evaluation of five methods for determining low-density lipoprotein cholesterol (LDL-C) in hemodialysis patients Eleni Bairaktari a, *, Moses Elisaf b, Christos Tzallas

More information

ASSESMENT OF LOW-DENSITY LIPOPROTEIN CHOLESTEROL BY HOMOGENEOUS ASSAY VERSUS FRIEDEWALD S EQUATION - A STUDY OF 50 CASES.

ASSESMENT OF LOW-DENSITY LIPOPROTEIN CHOLESTEROL BY HOMOGENEOUS ASSAY VERSUS FRIEDEWALD S EQUATION - A STUDY OF 50 CASES. Volume: I: Issue-1 May-July -2010 ASSESMENT OF LOW-DENSITY LIPOPROTEIN CHOLESTEROL BY HOMOGENEOUS ASSAY VERSUS FRIEDEWALD S EQUATION - A STUDY OF 50 CASES. Lincy Jacob 1, Ravikanth Medikonda 2, Piyush

More information

High-density Lipoprotein Cholesterol (HDL-C) Assay Kit

High-density Lipoprotein Cholesterol (HDL-C) Assay Kit (FOR RESEARCH USE ONLY. DO NOT USE IT IN CLINICAL DIAGNOSIS!) High-density Lipoprotein Cholesterol (HDL-C) Assay Kit (Double reagents) Catalog No: E-BC-K221 Method: Colorimetric method Specification: 96T

More information

The New Gold Standard for Lipoprotein Analysis. Advanced Testing for Cardiovascular Risk

The New Gold Standard for Lipoprotein Analysis. Advanced Testing for Cardiovascular Risk The New Gold Standard for Lipoprotein Analysis Advanced Testing for Cardiovascular Risk Evolution of Lipoprotein Testing The Lipid Panel Total Cholesterol = VLDL + LDL + HDL Evolution of Lipoprotein Testing

More information

EFFECT OF NICARDIPINE ON FASTING PLASMA LIPIDS AND APOLIPOPROTEINS IN MALE NEW ZEALAND WHITE RABBITS. Kamsiah Jaarin, Nafeeza MI*

EFFECT OF NICARDIPINE ON FASTING PLASMA LIPIDS AND APOLIPOPROTEINS IN MALE NEW ZEALAND WHITE RABBITS. Kamsiah Jaarin, Nafeeza MI* REVIEW ARTICLE Malaysian Journal of Medical Sciences, Vol. 6, No. 2, July 1999 (5-11) EFFECT OF NICARDIPINE ON FASTING PLASMA LIPIDS AND APOLIPOPROTEINS IN MALE NEW ZEALAND WHITE RABBITS Kamsiah Jaarin,

More information

行政院國家科學委員會補助專題研究計畫成果報告

行政院國家科學委員會補助專題研究計畫成果報告 NSC892314B002270 898 1 907 31 9010 23 1 Molecular Study of Type III Hyperlipoproteinemia in Taiwan β β ε E Abstract β Type III hyperlipoproteinemia (type III HLP; familial dysbetalipoproteinemia ) is a

More information

LDL (Human) ELISA Kit

LDL (Human) ELISA Kit LDL (Human) ELISA Kit Cat. No.:DEIA3864 Pkg.Size:96T Intended use This immunoassay kit allows for the specific measurement of human low density lipoprotein, LDL concentrations in cell culture supernates,

More information

Piccolo Lipid Panel Reagent Disc

Piccolo Lipid Panel Reagent Disc Piccolo Lipid Panel Reagent Disc Customer and Technical Service: 800-822-2947 Customers outside the US should contact their local Abaxis representative for customer service July 2011 PN: 400-7144-1 Rev.:

More information

Human LDL ELISA Kit. Innovative Research, Inc.

Human LDL ELISA Kit. Innovative Research, Inc. Human LDL ELISA Kit Catalog No: IRKTAH2582 Lot No: SAMPLE INTRODUCTION Human low-density lipoprotein (LDL) transports cholesterol from the liver to tissues where it is incorporated into cell membranes.

More information

J. Nutr. Sci. Vitaminol., 38, , Note. in Tissues

J. Nutr. Sci. Vitaminol., 38, , Note. in Tissues J. Nutr. Sci. Vitaminol., 38, 517-521, 1992 Note A Simple Enzymatic Quantitative in Tissues Analysis of Triglycerides Hiroshi DANNO, Yuu JINCHO, Slamet BUDIYANTO, Yuji FURUKAWA, and Shuichi KIMURA Laboratory

More information

Estimation of glucose in blood serum

Estimation of glucose in blood serum Estimation of glucose in blood serum Enzymatic estimation of glucose uses a reagent containing two enzymes and a chromogen. Glucose oxidase catalyses the oxidation of glucose to gluconolactone with the

More information

Laboratory Investigation of Dyslipidemia

Laboratory Investigation of Dyslipidemia CHEMISTRY Sridevi Devaraj, PhD Ishwarlal Jialal, MD, PhD, FRCPath, DABCC Laboratory Investigation of Dyslipidemia Cardiovascular disease is the leading cause of lesterol nor triglycerides are soluble in

More information

HDL CHOLESTEROL. 01 English - Ref.: 13. Ref.:13. Insert

HDL CHOLESTEROL. 01 English - Ref.: 13. Ref.:13. Insert HDL CHOLESTEROL Insert Ref.:13 Intended use. System for selective precipitation of Low and Very Low Density Lipoproteins (LDL and VLDL) and HDL cholesterol measurement in the supernatant, by an end point

More information

EliKine Free Thyroxine (ft4) ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit EliKine Free Thyroxine (ft4) ELISA Kit Booklet Item NO. KET0005 Product Name EliKine Free Thyroxine (ft4) ELISA Kit ATTENTION For laboratory research use only. Not for clinical or diagnostic use TABLE

More information

Small dense low-density lipoprotein is a risk for coronary artery disease in an urban Japanese cohort: The Suita study

Small dense low-density lipoprotein is a risk for coronary artery disease in an urban Japanese cohort: The Suita study Small dense low-density lipoprotein is a risk for coronary artery disease in an urban Japanese cohort: The Suita study Hidenori Arai 1, Yoshihiro Kokubo 2, Makoto Watanabe 2, Tatsuya Sawamura 3, Tomonori

More information

Patricia C. Fallest-Strobl, 1 Elin Olafsdottir, 2 Donald A. Wiebe, 1 and James O. Westgard 1 * Lipoproteins

Patricia C. Fallest-Strobl, 1 Elin Olafsdottir, 2 Donald A. Wiebe, 1 and James O. Westgard 1 * Lipoproteins Clinical Chemistry 43:11 2164 2168 (1997) Lipids and Lipoproteins Comparison of NCEP performance specifications for triglycerides, HDL-, and LDL-cholesterol with operating specifications based on NCEP

More information

V Rai, U Iyer, I Mani, U V Mani

V Rai, U Iyer, I Mani, U V Mani Serum Biochemical Changes in Insulin Dependent and Non-Insulin Dependent Diabetes Mellitus and their Role in the Development of Secondary Complications V Rai, U Iyer, I Mani, U V Mani ABSTRACT Fasting

More information

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date SYNCHRON System(s) Chemistry Information Sheet 2015 Beckman Coulter, Inc. All rights reserved. HDLD HDL Cholesterol 650207 For In Vitro Diagnostic Use ANNUAL REVIEW Rx Only Reviewed by Date Reviewed by

More information

Accuracy of Three Dry-Chemistry Methods for Lipid Profiling and Risk Factor Classification

Accuracy of Three Dry-Chemistry Methods for Lipid Profiling and Risk Factor Classification 358 International / Rubin Journal et al. of Sport Nutrition and Exercise Metabolism, 2003, 13, 358-368 2003 Human Kinetics Publishers, Inc. Accuracy of Three Dry-Chemistry Methods for Lipid Profiling and

More information

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON Page67 Available Online through IJPBS Volume 1 Issue 2 APRIL- JUNE 2011 SIMPLE QUANTITATIVE METHOD DEVELOPMENT AND VALIDATION OF VALSARTAN IN PUREFORM AND PHARMACEUTICAL DOSAGE FORMS BYUV SPECTROSCOPY

More information

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS Supplement VLDL LDL HDL PC 3.3 1.77 1.3 LPC 4.82 2.5.35 SM 3.1 4.6 1.92 CER 2.17 6.3 4.15 PE 3.18 1.93 2.79 PE-pl 13.18 1.9 2.32 CE 2.9.65.4 FC.36 3.5 2.54 Suppl. Table 1: CV of pooled lipoprotein fractions

More information

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Method development and validation of tenofovir disoproxil fumerate and emtricitabine in combined tablet

More information

S 102(e) Date: Nov. 23, 1998

S 102(e) Date: Nov. 23, 1998 US006057118A United States Patent (19) 11 Patent Number: 6,057,118 Nakamura et al. (45) Date of Patent: May 2, 2000 54 METHOD FOR QUANTITATIVELY 56) References Cited DETERMINING LDL CHOLESTEROLS U.S. PATENT

More information

ab Sphingomyelin Assay Kit

ab Sphingomyelin Assay Kit ab133118 - Sphingomyelin Assay Kit Instructions for Use For the specific, sensitive and convenient method of quantifying Sphingomyelin in plasma or serum. This product is for research use only and is not

More information

Available online at Scholars Research Library

Available online at  Scholars Research Library Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2015, 7 (3):157-161 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

BCH 447. Triglyceride Determination in Serum

BCH 447. Triglyceride Determination in Serum BCH 447 Triglyceride Determination in Serum Introduction: Triglycerides are esters of fatty acids and are hydrolyzed by lipase to glycerol and free fatty acids. Triglyceride determinations when performed

More information

Walter B. Bayubay CLS (ASCP), AMT, MA Ed, CPI

Walter B. Bayubay CLS (ASCP), AMT, MA Ed, CPI Walter B. Bayubay CLS (ASCP), AMT, MA Ed, CPI Biochemical Analysis (Lipid Panel) Analyte Total Cholesterol Reference Range Patient A < 200 241 LDL-C /= 40 38 Triglycerides

More information

APOB (Human) ELISA Kit

APOB (Human) ELISA Kit APOB (Human) ELISA Kit Catalog Number KA4330 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of the Assay...

More information

Plasma fibrinogen level, BMI and lipid profile in type 2 diabetes mellitus with hypertension

Plasma fibrinogen level, BMI and lipid profile in type 2 diabetes mellitus with hypertension World Journal of Pharmaceutical Sciences ISSN (Print): 2321-3310; ISSN (Online): 2321-3086 Published by Atom and Cell Publishers All Rights Reserved Available online at: http://www.wjpsonline.org/ Original

More information

Lipoprotein Quantification: An Electrophoretic Method Compared with the Lipid Research Clinics Method

Lipoprotein Quantification: An Electrophoretic Method Compared with the Lipid Research Clinics Method CLIN. CHEM. 2810, 2116-2120 (1982) Lipoprotein Quantification: An Electrophoretic Method Compared with the Lipid Research Clinics Method G. Russell Warnick, Thuy Nguyen,1 Robert 0. Bergelin,2 Patricia

More information

COMPARISON OF CALCULATED AND DIRECT LOW DENSITY LIPOPROTEIN CHOLESTEROL DETERMINATIONS IN A ROUTINE LABORATORY. A. A. AMAYO and S.

COMPARISON OF CALCULATED AND DIRECT LOW DENSITY LIPOPROTEIN CHOLESTEROL DETERMINATIONS IN A ROUTINE LABORATORY. A. A. AMAYO and S. 154 EAST AFRICAN MEDICAL JOURNAL March 2004 East African Medical Journal Vol. 81 No. 3 March 2004 COMPARISON OF CALCULATED AND DIRECT LOW DENSITY LIPOPROTEIN CHOLESTEROL DETERMINATIONS IN A ROUTINE LABORATORY

More information

Triglyceride determination

Triglyceride determination Triglyceride determination Introduction: - Triglycerides are esters of fatty acids and are hydrolyzed to glycerol and free fatty acids (by lipase) - Triglyceride determinations when performed in conjunction

More information

liquicolor Design Verification

liquicolor Design Verification Design Verification liquicolor 1 Introduction... 2 2 Imprecision... 2 2.1 Imprecision for... 2 2.2 Imprecision for... 2 3 Linearity and Detection Limit... 2 3.1 Linearity... 2 3.2 Detection Limit... 4

More information

A new on-line dual enzymatic method for simultaneous quantification of cholesterol and triglycerides in lipoproteins by HPLC

A new on-line dual enzymatic method for simultaneous quantification of cholesterol and triglycerides in lipoproteins by HPLC methods A new on-line dual enzymatic method for simultaneous quantification of cholesterol and triglycerides in lipoproteins by HPLC Shinichi Usui,* Yukichi Hara,* Seijin Hosaki, and Mitsuyo Okazaki 1,

More information

Supplemental Figure 1 ELISA scheme to measure plasma total, mature and furin-cleaved

Supplemental Figure 1 ELISA scheme to measure plasma total, mature and furin-cleaved 1 Supplemental Figure Legends Supplemental Figure 1 ELISA scheme to measure plasma total, mature and furin-cleaved PCSK9 concentrations. 4 Plasma mature and furin-cleaved PCSK9s were measured by a sandwich

More information

Cholesterol (blood, plasma, serum)

Cholesterol (blood, plasma, serum) 1 Cholesterol (blood, plasma, serum) 1 Name and description of analyte 1.1 Name of analyte Cholesterol (plasma; also blood, serum) 1.2 Alternative names 2,15-dimethyl-14-(1,5-dimethylhexyl)tetracyclo[8.7.0.0

More information

Chromatography on Immobilized Artificial Membrane

Chromatography on Immobilized Artificial Membrane Chromatography on Immobilized Artificial Membrane Principles of measuring compounds affinity to phospholipids using immobilized artificial membrane chromatography Chromatography on Immobilized Artificial

More information

Accuracy and Precision in Point-of-Care Lipid Testing: CardioChek P A Point-of-Care Test System and PTS Panels Test Strips

Accuracy and Precision in Point-of-Care Lipid Testing: CardioChek P A Point-of-Care Test System and PTS Panels Test Strips Accuracy and Precision in Point-of-Care Lipid Testing: CardioChek P A Point-of-Care Test System and PTS Panels Test Strips Sponsored by Arthur Roberts, MD of The Living Heart Foundation The Living Heart

More information

Hexagon PSA. Design Verification. Contents

Hexagon PSA. Design Verification. Contents Design Verification Hexagon PSA Contents 1. Function...2 2. Sensitivity, Dynamic Range and Traceability...2 Description of Control Materials...2 Analytical Sensitivity...2 3. Clinical Evaluation...3 Evaluation

More information

Measurement of cholesterol levels of the major serum. lipoprotein classes by anion-exchange high-performance

Measurement of cholesterol levels of the major serum. lipoprotein classes by anion-exchange high-performance JLR Papers In Press. Published on May 1, 2003 as Manuscript D300003-JLR200 Category: Method paper Title: Measurement of cholesterol levels of the major serum lipoprotein classes by anion-exchange high-performance

More information

Normal VLDL IDL LDL 1-2 HDL. Abnormal VLDL IDL LDL 1-7 HDL. Figure 1. Normal (Pattern A) and abnormal (Pattern B) lipoprotein profiles

Normal VLDL IDL LDL 1-2 HDL. Abnormal VLDL IDL LDL 1-7 HDL. Figure 1. Normal (Pattern A) and abnormal (Pattern B) lipoprotein profiles INTENDED USE AND INDICATIONS FOR USE The Quantimetrix Lipoprint System LDL Subfractions Kit Lipoprint LDL Kit is a device intended to measure lipoprotein cholesterol (for lipoprotein fractions and subfractions

More information

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser Evaluation Report Eurolyser HbA1c Test Kit on Smart and Cube Analyser Locations Location 1: Klinisk kemi University Hospital MAS Malmö Operator: Dr. Benny Larsson Date: June/July 2007 Location 2: Eurolyser

More information

General Chemistry Scheme Guide

General Chemistry Scheme Guide General Chemistry Scheme Guide Copyright WEQAS. All rights reserved. No part of this document may be reproduced or utilised in any form without permission from WEQAS Contents. Scheme details and repertoire.....

More information

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY Available online at www.ijrpc.com Research Article ABSORPTION CORRECTION METHOD AND SIMULTANEOUS EQUATION METHOD FOR THE SIMULTANEOUS ESTIMATION

More information

Human Oxidized LDL ELISA Kit (MDA-LDL Quantitation), General

Human Oxidized LDL ELISA Kit (MDA-LDL Quantitation), General Human Oxidized LDL ELISA Kit (MDA-LDL Quantitation), General For the detection and quantitation of human OxLDL in plasma, serum or other biological fluid samples Cat. No. KT-959 For Research Use Only.

More information

Serrata) Alkaline Phosphatase

Serrata) Alkaline Phosphatase Vol. 41, No. 5, April 1997 BIOCHEMISTRY and MOLECULAR BIOLOGY INTERNATIONAL Pages 951-959 An Essential Tryptophan Residue of Green Crab (Syclla Serrata) Alkaline Phosphatase Wen-Zhu Zheng 1, Qing-Xi Chen

More information

LIPID-ATHEROSCLEROSIS LABORATORY SERVICES GUIDE

LIPID-ATHEROSCLEROSIS LABORATORY SERVICES GUIDE LIPID-ATHEROSCLEROSIS LABORATORY SERVICES GUIDE Revised 3/2014 LIPID-ATHEROSCLEROSIS LABORATORY SERVICES GUIDE For questions concerning protocol and assay development, validation of results, etc., please

More information

Reagent-free, Simultaneous Determination of Serum Cholesterol in HDL and LDL by Infrared Spectroscopy

Reagent-free, Simultaneous Determination of Serum Cholesterol in HDL and LDL by Infrared Spectroscopy Clinical Chemistry 48:3 499 506 (2002) Lipids, Lipoproteins, and Cardiovascular Risk Factors Reagent-free, Simultaneous Determination of Serum Cholesterol in HDL and LDL by Infrared Spectroscopy Kan-Zhi

More information

Apolipoprotein A1 (Apo A1) ELISA

Apolipoprotein A1 (Apo A1) ELISA Package Insert Apolipoprotein A1 (Apo A1) ELISA 1 x 96 Wells For Research Use Only (RUO). Not for use in clinical, diagnostic or therapeutic procedures. v. 1.0 Eagle Biosciences, Inc. 20A Northwest Blvd.,

More information

Reference Material Institute for Clinical Chemistry Standards (ReCCS)

Reference Material Institute for Clinical Chemistry Standards (ReCCS) Reference Material Institute for Clinical Chemistry Standards (ReCCS) Certified Reference Material for Measurement of Total Cholesterol and Glycerides in Human Serum Certificate of Analysis Intended use

More information

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems. en CHOLESTEROL 7D62 304796/R02 CHOLESTEROL This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems. Read Highlighted Changes Revised October 2012 Package insert

More information

Measuring Lipid Composition LC-MS/MS

Measuring Lipid Composition LC-MS/MS Project: Measuring Lipid Composition LC-MS/MS Verification of expected lipid composition in nanomedical controlled release systems by liquid chromatography tandem mass spectrometry AUTHORED BY: DATE: Sven

More information

UREA CE Insert. 01 English - Ref.: 27. Ref.:27

UREA CE Insert. 01 English - Ref.: 27. Ref.:27 UREA CE Insert Ref.:27 Intended use. Colorimetric and enzymatic system for urea determination in samples of blood and urine, by end point reaction. Professional use. [Only for in vitro diagnostic use.]

More information

Rat cholesterol ELISA Kit

Rat cholesterol ELISA Kit Rat cholesterol ELISA Kit Catalog No. CSB-E11706r (96T) This immunoassay kit allows for the in vitro quantitative determination of rat Cholesterol concentrations in serum, plasma and other biological fluids.

More information

Traceable lipoprotein counting for Cardiovascular disease risk assessment Vincent DELATOUR, PhD

Traceable lipoprotein counting for Cardiovascular disease risk assessment Vincent DELATOUR, PhD Traceable lipoprotein counting for Cardiovascular disease risk assessment Vincent DELATOUR, PhD 1 The need for primary methods VIM 2008 : Primary reference measurement procedure : reference measurement

More information

Friedewald formula. ATP Adult Treatment Panel III L D L Friedewald formula L D L = T- C H O - H D L - T G / 5. Friedewald formula. Friedewald formula

Friedewald formula. ATP Adult Treatment Panel III L D L Friedewald formula L D L = T- C H O - H D L - T G / 5. Friedewald formula. Friedewald formula Friedewald formula 1 1 1,2 ATP Adult Treatment Panel III L D L Friedewald formula L D L = T- C H O - H D L - T G / 5 Friedewald formula Friedewald formula 2003 99 Friedewald formula Colorimetric method

More information

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET International Journal of Pharma and Bio Sciences RESEARCH ARTICLE ANALYTICAL CHEMISTRY DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET K.MYTHILI *, S.GAYATRI,

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE VITROS Chemistry Products Reagent 680 1728 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry Products Reagent is used on the VITROS 5,1 FS Chemistry System, the VITROS 4600 Chemistry

More information

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100) Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on CUBE analyser (CA0100) Location Location: Eurolyser Diagnostica GmbH Operators: Simone Wieser; Franz Helminger; Michael Gruber Date: July-November

More information

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2 JPSBR: Volume 5, Issue 2: 2015 (151-155) ISS. 2271-3681 A ew Gradient RP- HPLC Method for Quantitative Analysis of : (3-luoro-4- Morpholin-4-yl-Phenyl)-Carbamic Acid Methyl Ester and its Related Substances

More information

Quantitative Determination of Proteins

Quantitative Determination of Proteins UV-0003 Introduction One of the easiest and most accurate spectroscopic tool for determining protein concentration is by UV-Visible spectrophotometers. The V-630 is designed for biochemical analysis and

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

LIPASE liquicolor. Design Verification. Multipurpose Reagent

LIPASE liquicolor. Design Verification. Multipurpose Reagent Design Verification LIPASE liquicolor Multipurpose Reagent CONTENTS 1 Introduction... 2 2 Imprecision... 2 3 Linearity and Detection Limit... 2 3.1 Linearity... 2 3.2 Detection Limit... 3 4 Recovery of

More information

Development and Validation of a UV-Spectrophotometric Method for Quantification of Atorvastatin in Tablets

Development and Validation of a UV-Spectrophotometric Method for Quantification of Atorvastatin in Tablets Journal of PharmaSciTech 0; ():4-40 Research Article Development and Validation of a UV-Spectrophotometric Method for Quantification of Atorvastatin in Tablets Ghanty S*, Sadhukhan N, Mondal A Gupta College

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(5):8-14 ISSN: 0976-8688 CODEN (USA): PSHIBD Simultaneous UV-spectrophotometric estimation of bromhexine hydrochloride and

More information

Manual. Precision Red Advanced Protein Assay Reagent. Cat. # ADV02. cytoskeleton.com. Cytoskeleton, Inc.

Manual. Precision Red Advanced Protein Assay Reagent. Cat. # ADV02. cytoskeleton.com. Cytoskeleton, Inc. The Protein Experts Manual Cytoskeleton, Inc. V. 6.0 Precision Red Advanced Protein Assay Reagent Cat. # ADV02 cytoskeleton.com Phone: (303) 322.2254 Fax: (303) 322.2257 Customer Service: cserve@cytoskeleton.com

More information

Depleting Lipoproteins from Serum

Depleting Lipoproteins from Serum Depleting Lipoproteins from Serum Kathy K. Foxx Kalen Biomedical LLC President For decades, fetal bovine serum (FBS) has been used as a supplement for cell-culture media, providing the growth factors that

More information

Quantitative estimation of Rosuvastatin in bulk and tablet dosage form by using area under curve method

Quantitative estimation of Rosuvastatin in bulk and tablet dosage form by using area under curve method Original research article ISSN 2321-0125 www.jpbs-online.com Quantitative estimation of Rosuvastatin in bulk and tablet dosage form by using area under curve method P. S. Jain*, N. K. Kale, S. J. Surana

More information

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is 2, 4, 5-T. 1. Instrument Liquid Chromatograph-tandem mass spectrometer (LC-MS/MS)

More information

Available online Research Article

Available online   Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2016, 8(1):171-176 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Reverse phase high performance liquid chromatography

More information

THE CLINICAL BIOCHEMISTRY OF LIPID DISORDERS

THE CLINICAL BIOCHEMISTRY OF LIPID DISORDERS THE CLINICAL BIOCHEMISTRY OF LIPID DISORDERS Hormonal regulation INSULIN lipid synthesis, lipolysis CORTISOL lipolysis GLUCAGON lipolysis GROWTH HORMONE lipolysis CATECHOLAMINES lipolysis LEPTIN catabolism

More information

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 ( Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2015, 7 (5):44-49 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

DEVELOPMENT AND VALIDATION OF COLORIMETRIC METHODS FOR THE DETERMINATION OF RITONAVIR IN TABLETS

DEVELOPMENT AND VALIDATION OF COLORIMETRIC METHODS FOR THE DETERMINATION OF RITONAVIR IN TABLETS Int. J. Chem. Sci.: 8(1), 2010, 711-715 DEVELOPMENT AND VALIDATION OF COLORIMETRIC METHODS FOR THE DETERMINATION OF RITONAVIR IN TABLETS R. PRIYADARSINI *, V. NIRAIMATHI, T. SARASWATHY, V. GOPI and R.

More information

STORE AT 4 o C Version 3

STORE AT 4 o C Version 3 Instruction Manual Advanced Protein Assay Reagent (Cat. # ADV01) ORDERING INFORMATION To order by phone: (303) - 322-2254 To order by Fax: (303) - 322-2257 To order by e-mail: cserve@cytoskeleton.com Technical

More information