Chapter 6 IDENTIFICATION AND CHARACTERIZATION OF FLAVONOIDS BY HPLC AND LC-MS/MS ANALYSIS

Size: px
Start display at page:

Download "Chapter 6 IDENTIFICATION AND CHARACTERIZATION OF FLAVONOIDS BY HPLC AND LC-MS/MS ANALYSIS"

Transcription

1 Chapter 6 IDENTIFICATION AND CHARACTERIZATION OF FLAVONOIDS BY HPLC AND LC-MS/MS ANALYSIS

2 6.1 Introduction This chapter discusses the method development carried out for the identification and characterization of flavonoids on High Pressure Liquid Chromatography (HPLC) and Mass spectrometry (LC-MS). The first part of the chapter deals with an elaborate description of entire method development on HPLC for the separation and identification of flavonoid constituents along with the necessary modifications made in accordance to available literature. Second part of the chapter includes detailed description of Mass spectral studies for the characterization of flavonoid components followed by results and discussion section giving elaborate interpretation used for identification of individual compounds. 6.2 Experimental Chemicals Methanol and Acetonitrile of HPLC grade were obtained from Merck Pvt. Ltd. Quercetin and Kaempferol of purity > 99.8% were obtained from Sigma Aldrich, Germany. Formic acid was of AR grade % obtained from S.D. Fine Chem. Ltd Instrumentation HPLC Instrumentation HPLC analyses were conducted on a JASCO HPLC 1500 series connected to JASCO- MD-2010 plus multi-wavelength detector (PDA detector) as shown in Figure 6.1. LC system of JASCO series included JASCO-model PU-2080 intelligent HPLC pump equipped with JASCO-LG Ternary gradient unit, JASCO-DG line School of Science, SVKM s NMIMS (Deemed-to-be University) 137

3 degasser and JASCO-AS intelligent HPLC sampler having a variable (1-100µL) injection volume loop. Data obtained was analyzed and processed using the ChromNav offline processing software. The chromatographic separation was achieved using a Kromasil C18 column having dimensions of 4.6 x 250mm, particle size 5µm. Fig. 6.1: JASCO 1500 Series equipped with PDA detection system JASCO-1500 Series instrument comprised of JASCO-model-PU-1580 intelligent HPLC pump for constant flow and pressure modes. The pump works on 230V, 5A, equipped with front panel control keys to monitor pump operation, solvent flow mode selection, time program execution and display on the monitor screen. The LCD displays operating status such as, pressure readings, operating parameters and error messages. Apart from these, the other instrumental parts include, a solvent through which plunger washing solvent is drained off, purge valve allowing the solvent to flow out through drain tube, School of Science, SVKM s NMIMS (Deemed-to-be University) 138

4 pump head containing two chambers with inlet and outlet check valves for solvent delivery, and outlet port through which solvent from the pump is discharged. The front panel keypad controls all these functions and a rare panel controls gradient elution. In the constant flow mode, the flow rate range is mL min -1 with a flow precision of + 2% and a flow rate setting at mL min -1 increment. In another setting, the range mL min -1 increment is also available. The operating pressure ranges are kg/cm 2 ( ml min -1 ). In the constant pressure mode, the pressure range is kg/cm 2 with a setting at 10kg/cm 2 and precision of + 10%. The instrument is incorporated with JASCO-AS intelligent HPLC sampler with variable µl injection volume loop and a cooling facility (4 C). Fifty samples can be loaded to the sampler in a standard mode operation, while eighty four samples can be loaded in micro mode. The detector used is JASCO MD-2010 Plus Intelligent UV/VIS Multiwavelength detector. It comprises of four channels of which CH1 and CH3 calculate absorbance monitoring and CH4 calculates ratio channel output. The optical arrangement includes a single beam photometric detection with a flat-field polychromator. The wavelength range is nm and the PDA has 512 channels with a noise of x 10-5 AU. The light sources include deuterium and tungsten lamps. A PC-based ChromNAV, version chromatographic software with LC-Net II/ADC system is used for data integration. The software is configured with a calibration format where the drug concentration can be plotted against peak height or peak area or ratio of peak height or peak area of analyte to that of the internal standard to obtain the linear regression least square fit data of analysis Mass Spectrophotometer instrumentation Mass spectrometry analyses for the present study were done on 3 different systems. Initial LC-MS analysis was carried out MS system 1. The next MS system used was MS School of Science, SVKM s NMIMS (Deemed-to-be University) 139

5 system 2 and confirmatory results were obtained on MS system 3. All the three MS systems are described below. LC-MS System 1: LC-MS analysis was carried out using a Liquid Chromatograph Mass Spectrometer make of Varian Inc. USA having model 410 Prostar Binary LC with 500 MS IT PDA detector. LC-MS System 2: LC-MS analysis was carried out using a Shimadzu Liquid Chromatograph System LC- MS 2020 with Electrospray ionization (ESI) interface, and a single quadrupole analyzer. LC system was LC-20AD equipped with a PDA detector SPD-20AC, Oven CTO-20AC. The Lab Solutions software Version 5.53 SP2 from Shimadzu Pvt. Ltd. was used for data acquisition and evaluation. LC-MS System 3: LC-ESI/MS analysis was carried out using a Shimadzu liquid chromatographic system LC-MS LC system consisted of Nexsera HPLC system equipped with LC-20AD pump along with a UV detector SPD-20AC, Oven CTO-20AC which was connected to a quadrapole mass spectrophotometer. The Lab Solutions software Version5.53 SP2 from Shimadzu Pvt. Ltd. was used for data acquisition and evaluation Preparation of Working Standards and Sample Solutions Entire HPLC method development was done using two flavonol standards - Quercetin and Kaempferol. Preparation of standard solution was done using HPLC grade solvents. Working standard of Quercetin: 10mg Quercetin dissolved in methanol and made upto 10mL volume to yield a concentration of 1mg/mL. 1mL of this stock solution was taken in a 10mL volumetric flask and further diluted with 10mL School of Science, SVKM s NMIMS (Deemed-to-be University) 140

6 methanol to prepare a concentration of 100µg/mL. From this 100µg/mL solution, 1ml was taken and further diluted with 10mL methanol to give a concentration of 10µg/mL. This was then used for HPLC analysis. Working standard of Kaempferol: 10mg Kaempferol dissolved in methanol and made upto 10mL volume to yield a concentration of 1mg/mL. 1ml of this stock solution was taken and diluted with 10mL methanol to prepare a concentration of 100µg/mL. From this solution, 1ml was taken and further diluted with 10mL methanol to give a concentration of 10µg/mL. This was used for HPLC analysis. Both these working standards were used for optimization of HPLC conditions. Sample solutions: Isolated bands obtained from Prep-TLC were used as samples for analysis. There were four bands obtained from Prep-TLC, Prep Sample 1 (NB- 1), Prep Sample 2 (NB-2), Prep Sample 3 (NB-3) and Prep Sample 4 (NB-4). Each of them was dissolved in a specific amount of HPLC grade methanol to obtain its stock solution of 1mg/mL These stock solutions were used further with appropriate dilutions according to the requirement of the experiment RP-HPLC Method Development RP-HPLC mode of separation was carried out for the separation of isolated Prep-TLC bands. Literature review revealed the extensive use of RP-HPLC employed in the separation of phenolic/flavonoid compounds. Reverse Phase C18 columns with lengths in the range of 150mm to 250mm, having particle size of 5μm and an internal diameter of 4.6mm were found to be commonly employed for phenolic compounds. Therefore, taking this into consideration and on the basis of the available data, the column used for the School of Science, SVKM s NMIMS (Deemed-to-be University) 141

7 present study was Kromasil 100 RP 5C-18 with dimensions of 250mm x 4.6µm. The optimal detection wavelength for both, phenolic and flavonoid compounds were set at 280 in accordance with earlier work of Sun et al., (2007) and Burin et al., (2011). A preliminary study on the working standards was carried out, employing the isocratic mode of elution with a mobile phase comprising of Methanol: Acetonitrile: Water [31:10:59, v/v/v] reported by Zu et al., (2006). ph of the mobile phase was found to be This method is denoted as HPLC method 1. The UV spectrum of all the peaks was recorded in methanolic sample solutions and maximum absorption was observed in the full range from nm. Different channels were set for different wavelength using ChromNav software. The working standards, Quercetin and Kaempferol were injected individually to determine the exact retention time and their elution pattern. Thus the first chromatographic conditions set in HPLC Method 1 are as shown in Table 6.1. Reproducibility of the method was checked by injecting a standard solution in replicate (n=6). School of Science, SVKM s NMIMS (Deemed-to-be University) 142

8 Table 6.1: HPLC conditions for Method 1 Column Mobile Phase Flow Rate Detection Wavelength Kromasil 100 RP 5C-18 [250mm x 4.6mm, 5µm] Methanol: Acetonitrile: Water [ 31:10:59,v/v/v] ph mL/min nm [Entire Scan] 280nm Loading volume 20µL Standard Concentration Run length Quercetin and Kaempferol 10µg/mL 60 min Results obtained from HPLC method 1 suggested the need for changing HPLC parameters. Therefore, instead of direct analysis of the sample solutions, initial method development was done using working standards. HPLC method 1 was modified by changing the proportion of the mobile phase so as to enable a proper elution of standard solutions. Modified HPLC conditions set for Method 2 are shown in Table 6.2. Reproducibility of the method was checked by injecting standard solution in replicate (n=6). School of Science, SVKM s NMIMS (Deemed-to-be University) 143

9 Table 6.2: HPLC conditions for Method 2 Column Kromasil 100 RP 5C-18 [250mm x 4.6mm, 5µm] Mobile Phase Methanol : Acetonitrile: Water [ 34:10:56: v/v/v] ph Flow Rate Detection Wavelength 1.0mL/min nm [Entire Scan] 280nm Loading volume 20µL Working Standards Samples Run length Quercetin, Kaempferol (10µg/mL) Prep-TLC Bands, NB-1, NB-2 (20µg/mL) 60 min On the basis of the results obtained for working standards, Prep-TLC samples were also analyzed using HPLC Method 2. However, among the 4 isolated bands, NB-2 and NB-3 was of interest due to their TLC profile as discussed in Chapter 5. Hence preliminary HPLC analysis was done for NB-2 and NB-3 using Method 2. However this method did not bring about a separation of peaks in both the preparative samples. Hence the chromatographic conditions were slightly modified. The flow rate was lowered to 0.4mL/min to allow complete resolution of the peaks. Modified HPLC conditions set for Method 3 are shown in Table 6.3. Reproducibility of the method was checked by injecting standard solution in replicate (n=6). School of Science, SVKM s NMIMS (Deemed-to-be University) 144

10 Table 6.3: HPLC conditions for Method 3 Column Mobile Phase Flow Rate Detection Wavelength Kromasil 100 RP 5C-18 [250mm x 4.6mm, 5µm] Methanol : Acetonitrile: Water [ 34:10:56: v/v/v] ph mL/min nm [Entire Scan] 280nm Loading volume 20µL Working Standards Samples Run length Kaempferol (10µg/mL) Prep-TLC Bands, NB-1, NB-2 (20µg/mL) 60min Proper separation of peaks was observed for Prep-TLC bands NB-2 and NB-3. This optimized LC method was employed for Mass Spectrometry analysis for obtaining the molecular mass for each separated peak using LC-MS system 1. Mass spectrometry analysis was done by employing ESI positive ionization mode at capillary voltage of 80V. Scanning was performed from m/z 100 to However, no mass was observed for the peak under this optimized LC method. This was thought to be due to lack of ionization of peaks which plays a crucial role in mass spectral analysis. Although the optimized mobile phase was suitable for separation of samples, it was unable to cause enough ionization. Thus the lack of proper ionization was possibly on account of absence of acid in the above mentioned optimized mobile phase. Cech et al., (2001) had earlier observed that formic acid present in mobile phase helps to improve the ionization capacity by enhancing protonation. School of Science, SVKM s NMIMS (Deemed-to-be University) 145

11 The mobile phase was therefore modified by the introduction of 0.01% formic acid. Another modification involved lowering of the flow rate. A low flow rate is basically employed for increasing the time for ionization. HPLC conditions set for Method 4 are shown in Table 6.4. Table 6.4: HPLC conditions for Method 4 Column Mobile Phase Flow Rate Kromasil 100 RP 5C-18 [250mm X4.6mm] Methanol : 0.01% formic acid in Acetonitrile : 0.01% formic acid in Water [ 34:10:56: v/v/v] ph mL/min Detection Wavelength nm [Channel 9] Loading volume 20µL Sample name Run length Standard Kaempferol [15µg/mL] Prep NB-1 [20µg/mL] Prep NB-2 [20µg/mL] Prep NB-3 [20µg/mL] Prep NB-4 [20µg/mL] 100min Proper separation of peaks was observed under the above set conditions for all the Prep- TLC samples. These HPLC optimized parameters were then used for further LC-MS analysis for the identification of each peak of interest from Prep sample NB-2 and Prep sample NB-3. School of Science, SVKM s NMIMS (Deemed-to-be University) 146

12 6.2.5 Method Development on Mass Spectrometry Preliminary mass spectrometry analysis was done using LC-MS system 2. Further confirmatory study was carried out on LC-MS system Preliminary MS analysis of Kaempferol, Prep NB-2 and Prep NB-3 Preliminary MS analysis was undertaken by employing Electrospray Ionization [ESI] in both positive and negative mode for full scan using MS system 2 (Tsimogiannis et al., 2007). HPLC conditions were same as described in Table 6.4. MS system 2 used for this study was a Shimadzu liquid chromatographic system LC-MS Conditions set on MS system 2 are shown in Table 6.5. The Lab Solutions software version 5.53 SP2 from Shimadzu Pvt. Ltd. was used for data acquisition and evaluation. Table 6.5: MS conditions set on MS system 2 Parameters Interface Voltage Working Conditions 4.50kV Desolvation Line (DL) temperature 250 C Heat block temperature 400 C Nebulizing gas flow Drying gas flow 2.0 L/min 15.0 L/min Scanning range m/z School of Science, SVKM s NMIMS (Deemed-to-be University) 147

13 LC-MS/MS analysis of Pre NB-2 and NB-3 On the basis of results obtained from these preliminary studies, further fragmentation of the parent ion was done to get the product ion scan. MS system 3 used for this study was a HPLC system Nexsera coupled to Shimadzu Liquid Chromatographic System LC-MS Positive ionization mode was used to produce fragments of parent molecule. Conditions set on MS system 3 are as tabulated in Table 6.6. Data acquisition and interpretation was done with the Lab Solutions software version 5.53 SP2 from Shimadzu Pvt. Ltd. Table 6.6: MS conditions set on MS system 3 Parameters Interface Voltage Working Conditions 4.50kV Desolvation Line (DL) temperature 250 C Heat block temperature 400 C Nebulizing gas flow Drying gas flow 2.0 L/min 15.0 L/min Scanning range m/z Collision energy -65.0V Compounds were identified using the data obtained for their absorbance spectra (λ max ), parent mass and fragmentation patterns by comparing with available literature of standard compounds. School of Science, SVKM s NMIMS (Deemed-to-be University) 148

14 6.3 Results and Discussion HPLC method development Preliminary method development on HPLC was done using standard solutions of Quercetin and Kaempferol, each having a concentration of 10μg/mL. The different chromatographic conditions employed for method development have already been discussed under Section In HPLC Method 1, both the working standards Quercetin and Kaempferol eluted slowly with higher retention time. Figure 6.2 and Figure 6.3 shows the HPLC chromatogram observed for Quercetin and Kaempferol, respectively. Table 6.7 and 6.8 shows the reproducibility results obtained for Quercetin and Kaempferol under HPLC Method 1. School of Science, SVKM s NMIMS (Deemed-to-be University) 149

15 Figure 6.2: HPLC Chromatogram of Standard Quercetin under chromatographic conditions set for HPLC Method 1 Table 6.7: Reproducibility results of Quercetin for HPLC method 1 Observation no. t R (min) Peak Area Mean S.D % C.V School of Science, SVKM s NMIMS (Deemed-to-be University) 150

16 Figure 6.3: HPLC Chromatogram of Standard Kaempferol under chromatographic conditions set for HPLC Method 1 Table 6.8: Reproducibility results of Kaempferol for HPLC Method 1 Observation no. t R (min) Peak Area Mean S.D % C.V School of Science, SVKM s NMIMS (Deemed-to-be University) 151

17 Since the % C.V was less than 2% for the retention time as well as peak area, system suitability test passed the criteria of acceptance. Quercetin eluted with a retention time of 22 min whereas Kaempferol eluted later with a retention time of 35 min. Separation of polyphenolic compounds in reverse phase depends on the polarity of the compounds. Thus it is easy to predict the elution order of polyphenolic compounds in RP-HPLC. The elution order for separation of compounds is determined by their structural differences. Quercetin and Kaempferol are flavonol group of compounds with the same substitution pattern in the A flavone ring. Consequently, substitution in the B ring plays a major role in determining their elution order (Kulevanova et al., 2002). Quercetin contains two OH-groups at 3 and 4 position in the B-ring, whereas Kaempferol differs by having only one OH group in the 4 position. Owing to these structural differences, retention of both these compounds is affected by the number of OH-groups attached to the B-ring. Thus RP-HPLC follows the order of elution in compounds such that more polar (OH) groups are observed to have less retention on the reversed phase (non-polar), thereby eluting faster. Thus they show shorter retention time. Therefore, in a reverse phase system, the sample elution is retained for more hydrophobic compounds (Merken et al., 2000 and Kulevanova et al., 2002) Results obtained for HPLC Method 1 suggested the need for method development; hence the mobile phase composition was altered so as to bring about an early elution of the standard solutions. A study conducted by Snyder et al., (1997) indicated that the solvent system of the mobile phase has an effect on sample retention. Flavonoids are polyphenolic substances having three phenolic rings which results in stronger hydrophobic interaction with the stationary phase thereby resulting in longer retention. School of Science, SVKM s NMIMS (Deemed-to-be University) 152

18 Thus as a function of their molecular structure, greater amount of methanol is needed for elution of flavonoid compounds. Hence the mobile phase composition was slightly modified by changing the content of the organic solvent. Methanol content in the mobile phase was slightly increased. Figures 6.4 and 6.5 represent the chromatograms obtained for standard Quercetin and Kaempferol respectively under HPLC Method 2. Results of reproducibility for HPLC Method 2 are shown for Quercetin and Kaempferol in Tables 6.9 and 6.10, respectively. Figure 6.4: HPLC Chromatogram of Standard Quercetin under chromatographic conditions set for HPLC Method 2 School of Science, SVKM s NMIMS (Deemed-to-be University) 153

19 Table 6.9: HPLC Method 2: Reproducibility results of Quercetin Observation no. t R (min) Peak Area Mean S.D % C.V Figure 6.5: HPLC Chromatogram of Standard Kaempferol under chromatographic conditions set for HPLC Method 2 School of Science, SVKM s NMIMS (Deemed-to-be University) 154

20 Table 6.10: HPLC Method 2: Reproducibility results of Kaempferol Observation no. t R (min) Peak Area Mean S.D % C.V With an increase in the methanol content, the retention time of Quercetin and Kaempferol changed. Retention time of Quercetin and Kaempferol decreased to min and min, respectively. This could be attributed to the increase in the polarity of mobile phase ultimately resulting in faster elution of retained compounds. Since the % C.V was less than 2% for retention time as well as peak area, system suitability test passed the criteria of acceptance. The same mobile phase composition was employed for analysis of preparative samples. On the basis of the TLC profile obtained for the four preparative bands, NB-2 and NB-3 were selected as discussed earlier. Figures 6.6 and 6.7 shows the chromatograms obtained for Prep NB-2 and Prep NB-3, respectively under HPLC Method 2. School of Science, SVKM s NMIMS (Deemed-to-be University) 155

21 Figure 6.6: HPLC Chromatogram of Prep NB-2 under chromatographic conditions set for HPLC Method 2 Figure 6.7: HPLC Chromatogram of Prep NB-3 under chromatographic conditions set for HPLC Method 2 School of Science, SVKM s NMIMS (Deemed-to-be University) 156

22 As observed in the above chromatograms, peaks were obtained in Prep NB-2 and NB-3. However, no proper separation of peaks was observed for both the samples. Hence, in order to achieve a proper separation of peaks, the flow rate was lowered to 0.4mL/min (HPLC method 3). Figure 6.8 shows a chromatogram obtained for Kaempferol under HPLC Method 3. Reproducibility data obtained for standard Kaempferol (n=6) under HPLC method 3 are shown in Table Under these conditions, separation was observed for the peaks in NB-2 and NB-3, results of which are depicted in Figures 6.9 and 6.10 for NB-2 and NB-3 respectively. Reproducibility of the peaks for NB-2 and NB-3 was studied by analyzing sample in triplicate. These results are shown in Table Figure 6.8: HPLC Chromatogram of Kaempferol under chromatographic conditions set for HPLC Method 3 School of Science, SVKM s NMIMS (Deemed-to-be University) 157

23 Table 6.11: Reproducibility results of HPLC Method 3 Observation no. Kaempferol t R (min) Peak Area Mean S.D %CV Figure 6.9: HPLC Chromatogram of NB-2 under chromatographic conditions set for HPLC Method 3 School of Science, SVKM s NMIMS (Deemed-to-be University) 158

24 Figure 6.10: HPLC Chromatogram of NB-3 under chromatographic conditions set for HPLC Method 3 Table 6.12: Reproducibility results of NB-2 and NB-3 for HPLC method 3 Observation no. NB-2 NB-3 t R (min) Peak Area t R (min) Peak Area Mean S.D %RSD Thus the HPLC conditions as given in HPLC Method 3 were optimized for separation of peaks of interest. School of Science, SVKM s NMIMS (Deemed-to-be University) 159

25 6.3.2 Preliminary MS analysis of Prep sample Electrospray Ionization (ESI) was employed for preliminary mass analysis employing both, the positive and negative mode. Prep NB-3 was analyzed using ESI-MS (positive ionization) under HPLC method 3. Figure 6.11 shows the ESI-MS spectrum observed for NB-3. Figure 6.11: ESI MS spectra for NB-3 under positive ionization As seen in above figure, there was no significant ionization observed at expected retention time. As discussed in earlier section of this chapter, this was thought to be due to improper ionization of peaks. Thus the optimized mobile phase was not suitable for causing ionization of molecule. This could have been due to lack of acid in mobile phase. Presence of formic acid in mobile phase has been reported to improve its ionization capacity by enhancing protonation (Cech et al., 2001) School of Science, SVKM s NMIMS (Deemed-to-be University) 160

26 The mobile phase was thus modified by introduction of 0.01% formic acid and flow rate was lowered to 0.2mL/min to provide more time for proper ionization. All the preparative samples were properly separated using above conditions. Figure 6.12 shows the chromatogram for Kaempferol under HPLC Method 4 and the reproducibility results for the same are shown in Table Figures 6.13, 6.14, 6.15 and 6.16 show the chromatograms of NB-1, NB-2, NB-3 and NB-4 under HPLC Method 4. Reproducibility results for all prep samples are shown in Table Figure 6.12: HPLC Chromatogram of Kaempferol under chromatographic conditions set for HPLC Method 4 School of Science, SVKM s NMIMS (Deemed-to-be University) 161

27 Table 6.13: Reproducibility results of Kaempferol for HPLC Method 4 Observation no. t R (min) Peak Area Mean S.D % C.V Figure 6.13: HPLC Chromatogram of NB-1 under chromatographic conditions set for HPLC Method 4 School of Science, SVKM s NMIMS (Deemed-to-be University) 162

28 Figure 6.14: HPLC Chromatogram of NB-2 under chromatographic conditions set for HPLC Method 4 Figure 6.15: HPLC Chromatogram of NB-3 under chromatographic conditions set for HPLC Method 4 School of Science, SVKM s NMIMS (Deemed-to-be University) 163

29 Figure 6.16: HPLC Chromatogram of NB-4 under chromatographic conditions set for HPLC Method 4 Peak purity Under this optimized HPLC conditions (Method 4), peak purity was checked using PDA for the standard Kaempferol as well as for the peaks of interest. The peak purity for kaempferol was found to be 98.9% whereas for NB-2 and NB-3 the values were 98.1% and 99.8% respectively. School of Science, SVKM s NMIMS (Deemed-to-be University) 164

30 Table 6.14: Reproducibility results of NB-1, NB-2, NB-3 and NB-4 for HPLC Method 4 Reading no. t R NB-1 NB-2 NB-3 NB-4 Peak t R (min) Area (min) Peak Area t R (min) Peak Area t R Peak (min) Area Mean S.D %RSD % RSD observed was less than 2% which was within the acceptance criteria and thus the HPLC method also gave reproducible results Tentative identification of Preparative samples from HPLC Elution Profile and UV spectra For all the four preparative samples, tentative identification of compounds was done on the basis of their elution pattern on HPLC and their spectra obtained through PDA. Absorption maxima for each peak were compared with available literature for standard compounds. Figures 6.17 and 6.18, illustrate UV spectra obtained for Standard Kaempferol and Quercetin, respectively. School of Science, SVKM s NMIMS (Deemed-to-be University) 165

31 266nm 367nm Figure 6.17: UV spectra of Standard Kaempferol 253nm 370nm Figure 6.18: UV spectra of Standard Quercetin Figure 6.19 (a) and (b) shows the HPLC profile of NB-1 and its UV spectrum respectively. Figure 6.20 (a) and (b) shows the HPLC profile of NB-2 and its UV spectrum respectively. Figure 6.21 (a) and (b) shows the HPLC profile of NB-3 and its UV spectrum respectively. Figure 6.22 (a) and (b) shows the HPLC profile of NB-4 and its UV spectrum respectively. School of Science, SVKM s NMIMS (Deemed-to-be University) 166

32 (a) (b) Figure 6.19: (a) HPLC profile of NB-1 and (b) UV spectrum of peak (tr = 21 min) School of Science, SVKM s NMIMS (Deemed-to-be University) 167

33 (a) Figure 6.20: (a) HPLC profile of NB-2 and (b) UV spectrum of peak (tr = 29 min) (b) School of Science, SVKM s NMIMS (Deemed-to-be University) 168

34 (a) (b) Figure 6.21: (a) HPLC profile of NB-3 and (b) UV spectrum of peak (tr = 47 min) School of Science, SVKM s NMIMS (Deemed-to-be University) 169

35 (a) (b) Figure 6.22: (a) HPLC profile of NB-4 and (b) UV spectrum of peak (tr = 26 min) School of Science, SVKM s NMIMS (Deemed-to-be University) 170

36 6.3.4 Spectral analysis of NB-1 and NB-4: Spectral data obtained for NB-1 and NB-4 showed two major absorbance maxima at 245 and 325 nm and a shoulder peak at 294nm. This spectral characteristic is similar to that observed for phenolic acids (Lin and Harnly, 2010). In addition, NB-1 (t R = 21 min) and NB-4 (t R = 26 min) eluted much earlier as compared to standard Kaempferol (t R = 85 min). These elution patterns for phenolic acid and flavonol aglycones were in agreement with those observed earlier by Jianping et al., (2007) in their study on red wines wherein phenolic acids eluted much faster than flavonoids. This could be attributed to more polar nature of phenolic acids than flavonoids. Basically the structure of flavonol compounds contains a 4-keto functional group which increases the hydrophobicity of the molecule by forming a planar non-polar six-member ring; making it less polar to the solvent. Moreover, the unsaturation between positions 2 and 3 of the pyran ring on the flavonoid molecule is also known to make the compound much less polar due to a larger electron density on the oxygen atom of the 4-keto group thus explaining the higher retention time encountered for flavonols i.e. Quercetin and Kaempferol (Wulf and Nagel, 1976). Thus, on the basis of their TLC profile, HPLC elution pattern and UV spectra, NB-1 and NB-4 were tentatively identified as phenolic acids. However, further identification by MS was not carried out for these samples as main focus of the study was flavonoid group of compounds Spectral analysis of NB-2 and NB-3 Spectral data obtained for NB-2 were similar to that of Quercetin when compared with the standard compound. However, retention time observed was completely different for both. There was a possibility of this peak being glycosidic form of Quercetin as glycosylation is known to affect the elution pattern. These results are in agreement with those of Wulf and Nagel, (1976) who earlier reported that flavonoid glycosides are more School of Science, SVKM s NMIMS (Deemed-to-be University) 171

37 polar than flavonoid aglycones and that glycosylation results in faster elution of compounds. Quercetin glycoside eluted faster than its aglycone form and this could be due to increase in polarity of molecule by addition of sugar moiety. Spectral data obtained for NB-3 was similar to that of standard Kaempferol. However, similar effect was observed for NB-3 as observed for NB-2. Retention time of standard Kaempferol was high as compared to that of NB-3. Therefore, there was possibility of NB-3 to be present in glycosidic form of Kaempferol. The observed results were in accordance to remarks made by Spanos et al., (1990) who reported a change in the retention time of an aglycone (free molecule) esterified with a carboxylic acid or with a sugar moiety. This variation in retention time would be due to the difference in the polarity of the molecule. Therefore on the basis of this literature, it was more crucial to obtain MS data to ensure the identification of peaks as many different compounds belonging to the same family show similar scan spectra. Thus Prep NB-2 and NB-3 were subjected to MS/MS analysis for their identification Preliminary LC-MS analysis of Kaempferol, Prep NB-2 and Prep NB-3 Initial LC-ESI-MS data for standard Kaempferol, Prep NB-2 and Prep NB-3 was obtained using Shimadzu Liquid Chromatographic System LC-MS ESI-MS analysis was done using both positive and negative ionization mode. ESI-MS analysis of standard Kaempferol produced a parent ion [M-H] + at m/z 287 in positive mode and [M-H] - at m/z 285 in negative mode. Figures 6.23 (a) and (b) shows ESI-MS spectra obtained for Kaempferol in the positive and negative ionization modes respectively while Figures 6.24 (a), (b) and 6.25 (a), (b) show ESI-MS spectra obtained for NB-2 and NB-3 in the positive and negative ionization modes respectively. School of Science, SVKM s NMIMS (Deemed-to-be University) 172

38 Figure 6.23 (a): ESI-MS spectrum of Standard Kaempferol in Positive ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 173

39 Figure 6.23 (b): ESI-MS spectrum of Standard Kaempferol in Negative ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 174

40 Figure 6.24 (a): ESI-MS spectrum of NB-2 in Positive ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 175

41 Figure 6.24 (b): ESI-MS spectrum of NB-2 in Negative ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 176

42 Figure 6.25 (a): ESI-MS spectrum of NB-3 in Positive ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 177

43 Figure 6.25 (b): ESI-MS spectrum of NB-3 in Negative ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 178

44 6.3.7 LC-ESI-MS analysis of NB 2 LC-ESI-MS analysis of NB-2 produced a parent ion [M-H] + at m/z 465 in the positive ionization mode and [M-H] - at m/z 463 in the negative ionization mode. Hence NB-2 had a molecular weight of 464 which was same as that reported by Lin and Harnly, (2007) for Quercetin glycoside. The possibility of this compound being a quercetin glycoside was justified by its orange colour which developed in TLC and which is characteristic of Quercetin and its derivatives. UV spectra observed matched with the reported UV spectra for Quercetin glycoside (Lin and Harnly, 2007) LC- ESI-MS analysis of NB-3 LC- ESI-MS analysis of NB-3 produced a parent ion [M-H] + at m/z 449 in positive ionization mode and [M-H] - at m/z 447 in negative ionization mode. Thus NB-3 had a molecular weight of 448 which on comparison with available literature was same as that reported for glycoside of Kaempferol, Quercetin and Luteolin (De Brito et al 2007; Lin and Harnly, 2007, 2010; Wan et al., 2011). However among the speculated compounds, TLC profile of NB-3 did not match with Quercetin glycoside. Moreover, comparison of UV spectra of NB-3 with luteolin showed slight variations thereby ruling out the possibility of luteolin. However, further fragmentation of aglycones was done to clarify difference in flavonol and flavone structure LC-MS/MS analysis of Prep NB-2 and Prep NB-3 The fragmentation pattern of flavonoid compounds serves as a highly diagnostic tool for identifying specific classes of compounds. This makes it possible to obtain a precise structural elucidation of the aglycone by comparison with the reported data (Fabre et al. 2001; Cuyckens et al., 2001) School of Science, SVKM s NMIMS (Deemed-to-be University) 179

45 The system used for obtaining the fragmentation pattern of NB-2 and NB-3 was Shimadzu LC-MS The fragmentation pattern was obtained using both the ionization modes for the precursor molecule so as to identify the aglycone moiety. However, the negative ionization mode was unable to produce characteristic fragments for each flavonoid subgroup which may be deduced from the earlier data published by Fabre et al., (2001); Hughes et al., (2001); Wu et al.,(2004) in their studies on flavonoids groups. Figure 6.26 shows the product ion scan obtained for m/z 465 in the positive ionization mode. School of Science, SVKM s NMIMS (Deemed-to-be University) 180

46 Figure 6.26: ESI-MS /MS spectrum of m/z 465 in Positive ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 181

47 As observed above in the ESI-MS/MS spectrum, the product ion scan of m/z 465, generated a ion with m/z 303 indicating the loss of 162 amu from the pseudomolecular ion [M H] + (m/z 465). This loss of 162 indicated attachment of the sugar moiety (hexose) to the aglycone part indicating that it was present in glycosidic form and not as an aglycone. The remaining aglycone part with m/z 303 indicated it to be quercetin as observed earlier by Tsimogiannis et al., (2007). Figure 6.27 explains the loss of the sugar moiety taking place from Quercetin glycoside while Figure 6.28 explains the Cleavage of Quercetin aglycone at different positions in the C-ring. In addition, Quercetin aglycone with m/z 303 produced characteristic fragments for the flavonol group. The characteristic fragments observed with m/z 257, 275, 165 and 153 were similar to the results reported by Tsimogiannis et al., (2007) in their study on phenolic compounds. They reported similar characteristic fragments for standard Quercetin in their study on the fragmentation pattern of twelve selected flavonoids. A product ion scan of quercetin aglycone m/z 303 showed the formation of an ion with m/z 257 which could be attributed to loss of water and carbon monoxide by forming [M+H-H 2 O-CO] +. Moreover, an ion was obtained at m/z 275 indicating the direct loss of carbon monoxide from the protonated aglycone through the formation of [M+H-CO] +. School of Science, SVKM s NMIMS (Deemed-to-be University) 182

48 H + [Aglc-H] + m/z 303 Sugar moiety m/z 162 Figure 6.27 : Cleavage of glycosidic bond to yield quercetin aglycone and the sugar moiety School of Science, SVKM s NMIMS (Deemed-to-be University) 183

49 [M-H] + (m/z = 303) 1,3 B + H + 0,2 A + B A C 0,2 B + 1,3 A + 0,2 A + = 165 1,3 A + = 153 Figure 6.28: Cleavage of Quercetin aglycone at different positions in the C-ring School of Science, SVKM s NMIMS (Deemed-to-be University) 184

50 As shown in the above Figure 6.28, formation of fragments with m/z 153 and 165 were due to C-ring cleavage of the aglycone structure. As noted earlier by Cuyckens & Claeys, (2004) and De Rijke et al., (2006), formation of fragment 153 was likely to be due to the cleavage between bond 1 and 3 which is most commonly observed and constitutes abundant fragment ion for the flavonol group. Moreover, presence of 0,2 A + fragment with m/z 165 has been exclusively assigned to the group of flavonols containing an additional hydroxyl group at 3 position which is present in the structure of Quercetin. Thus NB-2 was identified as a Quercetin glycoside on the basis of its UV spectrum, parent mass and fragmentation pattern. Figure 6.29 shows the product ion scan obtained for m/z 449 in the positive ionization mode. School of Science, SVKM s NMIMS (Deemed-to-be University) 185

51 Figure 6.29: ESI-MS /MS spectrum of m/z 449 in NB-3 in Positive ionization mode School of Science, SVKM s NMIMS (Deemed-to-be University) 186

52 As observed above, the product ion scan of m/z 449, generated an ion with m/z 287 indicating the the loss of 162 amu from the pseudomolecular ion [M H] + (m/z 449). This loss of 162 indicated attachment of the sugar moiety (hexose) to the aglycone part. The remaining aglycone part with m/z 287 indicated it to be kaempferol aglycone as noted by Tsimogiannis et al., (2007). Figure 6.30 explains the loss of the sugar moiety taking place from Kaempferol glycoside while Figure 6.31 explains the Cleavage of Kaempferol aglycone at different positions in the C-ring. Kaempferol aglycone with m/z 287 produced characteristic fragments for the flavonol group. Fragments with m/z 213,165,153 and 121 were similar to those reported by Tsimogiannis et al., (2007). They recorded similar characteristic fragments for standard Kaempferol. Among the fragments, formation of an ion with m/z 213 could be attributed to the loss of water and carbon monoxide through the formation of [M+H-H 2 O-CO] +. School of Science, SVKM s NMIMS (Deemed-to-be University) 187

53 [Aglc-H] + m/z 287 Sugar moiety m/z 162 Figure 6.30: Cleavage of glycosidic bond to form kaempferol aglycone and sugar moiety School of Science, SVKM s NMIMS (Deemed-to-be University) 188

54 [M-H] + (m/z = 287) 0,2 A + = 165 1,3 A + = 153 0,2 B + = 121 Figure 6.31 : Cleavage of Kaempferol aglycone at different positions in the C-ring School of Science, SVKM s NMIMS (Deemed-to-be University) 189

55 As observed above, fragment with m/z 153 and 121 indicated a cleavage between bond 1 and 3 which represents the common fragments observed for flavonoids. The fragment with m/z 153 contained the A ring whereas the fragment with m/z 121 contained the B- ring. Moreover, presence of 0,2 A + with m/z 165 confirmed that the compound belonged to the flavonol group and which is exclusively used to distinguish flavonols from other subgroups. This ion does not occur in the spectra of the other subclasses of flavonoids (De Rijke et al., 2006). This difference in formation of 165 mass at the cleavage between 0 and 2 bonds could be attributed to the presence of an additional 3-OH group which is specific to the group of flavonols. Hence, the possibility of the compound being luteolin was ruled out as it did not show the presence of fragment of m/z 165. A review paper by Pinheiro and Justino, (2010) provides supportive evidence for this fact. They also reported the presence of 0,2 A + fragment to be exclusively assigned to the group of flavonols containing an additional hydroxyl group at position 3. Thus NB-3 was identified as a Kaempferol glycoside on the basis of its UV spectrum, parent mass and fragmentation pattern. School of Science, SVKM s NMIMS (Deemed-to-be University) 190

56 6.4 Conclusion Important conclusions drawn from the results obtained in HPLC method development and Mass spectrometry analysis are as follows: RP-HPLC-DAD method was successfully developed for separation of preparative samples, isolated from Nyctanthes arbor-tristis L. On the basis of the results obtained from TLC profile, HPLC elution pattern and UV spectra, NB-1 and NB-4 belong to phenolic acids whereas NB-2 and NB-3 were identified as flavonols. Under optimized HPLC conditions there were differences in the HPLC elution patterns for phenolic acids and flavonoids with phenolic acids eluting faster than flavonoids. The peaks of interest showed high purity values with NB-2 having a value of 98.1% and NB-3 with a value of 99.8%. Electrospray Ionization (ESI) with positive and negative mode of ionization provided useful data of molecular mass of the parent molecule as well for the characteristic fragmentation pattern. NB-2 was found to be a Quercetin glycoside while NB-3 was a Kaempferol glycoside. School of Science, SVKM s NMIMS (Deemed-to-be University) 191

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Application Note Food Testing & Agriculture Author Edgar Naegele Agilent Technologies,

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Application Note Food Testing Author Edgar Naegele

More information

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography

More information

Steviol Glycosides from Stevia rebaudiana Bertoni

Steviol Glycosides from Stevia rebaudiana Bertoni 0 out of 21 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 Steviol Glycosides from Stevia rebaudiana Bertoni This monograph

More information

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms Asian Journal of Chemistry Vol. 22, No. 7 (2010), 5067-5071 RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms A. LAKSHMANA RAO*, G. TARAKA RAMESH and J.V.L.N.S. RAO Department of Pharmaceutical

More information

Available online Research Article

Available online   Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2015, 7(12):519-523 Research Article ISSN : 0975-7384 CDEN(USA) : JCPRC5 Characterization of cyanidin 3-(6-acetylglucoside)-5-(3

More information

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D

More information

2D-LC as an Automated Desalting Tool for MSD Analysis

2D-LC as an Automated Desalting Tool for MSD Analysis 2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja

More information

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE Int. J. Chem. Sci.: 6(1), 2008, 441-446 A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE S. APPALA RAJU, ARVIND B. KARADI and SHOBHA MANJUNATH HKES s College of Pharmacy,

More information

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Neosolaniol. [Methods listed in the Feed Analysis Standards] Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]

More information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and

More information

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

Vitamin D3 and related compounds by ESI and APCI

Vitamin D3 and related compounds by ESI and APCI Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate

More information

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki

More information

Phospholipid characterization by a TQ-MS data based identification scheme

Phospholipid characterization by a TQ-MS data based identification scheme P-CN1716E Phospholipid characterization by a TQ-MS data based identification scheme ASMS 2017 MP-406 Tsuyoshi Nakanishi 1, Masaki Yamada 1, Ningombam Sanjib Meitei 2, 3 1 Shimadzu Corporation, Kyoto, Japan,

More information

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 641 Triple Quadrupole LC/MS system Application Note Clinical Research Author Siji Joseph Agilent Technologies Bangalore, India

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies. Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

Agilent 1260 Infinity Analytical SFC System

Agilent 1260 Infinity Analytical SFC System Agilent 1260 Infinity Analytical SFC System Installation Instructions: Checkout Procedure This technical note describes the checkout procedures for the Agilent 1260 Infinity Analytical SFC System. Contents

More information

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS Int. J. Chem. Sci.: 6(1), 2008, 399-404 REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS S. APPALA RAJU, ARVIND B. KARADI and SHOBHA MANJUNATH HKES s

More information

Amudha S et al., Asian Journal of Pharmthiaceutical Technology & Innovation, 04 (21); 2016; Research Article

Amudha S et al., Asian Journal of Pharmthiaceutical Technology & Innovation, 04 (21); 2016; Research Article Asian Journal of Pharmaceutical Technology & Innovation ISSN: 2347-8810 Research Article Received on: 09-11-2016 Accepted on: 20-11-2016 Published on: 15-12-2016 Corresponding Author: * Amudha S, Dept.

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form S. LAVANYA* 1, SK. MANSURA BEGUM 1, K. NAGAMALLESWARA RAO 2, K. GAYATHRI DEVI 3 Department of pharmaceutical

More information

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC Chapter III Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC 1. INTRODUCTION Phenolics compounds are naturally present antioxidants, found in a variety of plant

More information

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D

More information

THIN LAYER CHROMATOGRAPHY

THIN LAYER CHROMATOGRAPHY THIN LAYER CHROMATOGRAPHY Thin layer chromatography is the best known technique of plant biochemistry. TLC is used for preliminary separation and determination of plant constituents. It is helpful for

More information

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079 Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for

More information

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector application Note Liquid Chromatography Author Njies Pedjie PerkinElmer, Inc. Shelton, CT 06484 USA Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped

More information

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Method development and validation of tenofovir disoproxil fumerate and emtricitabine in combined tablet

More information

Validation of UV Spectrophotometric and HPLC Methods for Quantitative determination of Iloperidone in Pharmaceutical Dosage Form

Validation of UV Spectrophotometric and HPLC Methods for Quantitative determination of Iloperidone in Pharmaceutical Dosage Form International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.4, No.2, pp 576-581, April-June 2012 Validation of UV Spectrophotometric and HPLC Methods for Quantitative determination

More information

International Journal of Applied Pharmaceutical Sciences and Research

International Journal of Applied Pharmaceutical Sciences and Research International Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 Anas et al/international Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 International

More information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F

More information

High-Performance Liquid Chromatography-Mass Spectrometry for the Determination of Flavonoids in G.biloba Leaves

High-Performance Liquid Chromatography-Mass Spectrometry for the Determination of Flavonoids in G.biloba Leaves Food Science and Technology Research, 22 (2), 199 _ 204, 2016 Copyright 2016, Japanese Society for Food Science and Technology doi: 10.3136/fstr.22.199 http://www.jsfst.or.jp Technical paper High-Performance

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

Measuring Lipid Composition LC-MS/MS

Measuring Lipid Composition LC-MS/MS Project: Measuring Lipid Composition LC-MS/MS Verification of expected lipid composition in nanomedical controlled release systems by liquid chromatography tandem mass spectrometry AUTHORED BY: DATE: Sven

More information

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Power of QTRAP Systems for Identification and Confirmation of Degradation Products Dilip Reddy 1, Chandra Sekar

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(1):138-144 Simultaneous RP HPLC determination of Latanoprost

More information

International Journal of Applied Pharmaceutical Sciences and Research

International Journal of Applied Pharmaceutical Sciences and Research International Journal of Applied Pharmaceutical Sciences and Research Research Article http://dx.doi.org/10.21477/ijapsr.v2i03.8254 Analytical Separation and Characterisation of Degradation Products and

More information

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of 4.1. Introduction Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of eyes. The disease is characterized by lesser or some time no-significant production of tear;

More information

Mass Spectrometry. Actual Instrumentation

Mass Spectrometry. Actual Instrumentation Mass Spectrometry Actual Instrumentation August 2017 See also http://www.uni-bielefeld.de/chemie/analytik/ms f additional infmation 1. MALDI TOF MASS SPECTROMETRY ON THE ULTRAFLEX 2 2. ESI MASS SPECTROMETRY

More information

SUPPLEMENTARY MATERIAL

SUPPLEMENTARY MATERIAL SUPPLEMENTARY MATERIAL Artepillin C, is it a good marker for quality control of Brazilian Green Propolis? Cui-ping Zhang 1, Xiao-ge Shen 1, Jia-wei Chen 1, Xia-sen Jiang 1, Kai Wang 2, Fu-liang Hu 1 *

More information

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW 132 CHAPTER 6 DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF PARACETAMOL, TRAMADOL HYDROCHLORIDE AND DOMPERIDONE IN A COMBINED DOSAGE FORM 6.1 INTRODUCTION

More information

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 10(4), 2012, 2039-2047 ISSN 0972-768X www.sadgurupublications.com DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

More information

Supporting Information. 58 Pages. 6 Figures 4 Tables

Supporting Information. 58 Pages. 6 Figures 4 Tables Light-Source-Dependent Effects of Main Water Constituents on Photodegradation of Phenicol Antibiotics: Mechanism and Kinetics Linke Ge, Jingwen Chen, * Xianliang Qiao, Jing Lin, Xiyun Cai Key Laboratory

More information

Edgar Naegele. Abstract

Edgar Naegele. Abstract Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in

More information

Scholars Research Library

Scholars Research Library Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2010, 2(2): 294-299 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column Application Note Clinical Research LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell EC C8 Column Authors Rongjie Fu and Zhiming Zhang Agilent Technologies

More information

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Single Quadrupole Compact Mass Spectrometer for Liquid Sample Single Quadrupole Compact Mass Spectrometer for Liquid Sample YL INSTRUMENT CO., LTD. YL9900 MS quickly provides essential information and improves the chemist's workflow. Mordern organic labs have become

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 11(4), 2013, 1607-1614 ISSN 0972-768X www.sadgurupublications.com DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

More information

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods

More information

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety Determination of Aflatoxins in Food by LC/MS/MS Application Food Safety Authors Masahiko Takino Agilent Technologies 9-1 Takakura-Cho Hachiouji-Shi, Tokyo Japan Toshitsugu Tanaka Kobe Institute of Health

More information

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM Int. J. Chem. Sci.: 6(3), 2008, 1576-1582 SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM B. NEELIMA, P. RAVI KUMAR, M. MURALI KRISHNA, V. HIMA

More information

Designer Cannabinoids

Designer Cannabinoids Liquid Chromatography Mass Spectrometry SSI-LCMS-010 Designer Cannabinoids LCMS-8030 Summary A rapid LC-MS-MS method for determination of designer cannabinoids in smokeable herbs was developed. Background

More information

Analysis of HMF by HPLC

Analysis of HMF by HPLC COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl

More information

CAMAG TLC-MS INTERFACE

CAMAG TLC-MS INTERFACE CAMAG TLC-MS INTERFACE 93.1 249.2 40 30 97.1 20 10 250.2 0 200 400 m/z WORLD LEADER IN PLANAR-CHROMATOGRAPHY Identification and elucidation of unknown substances by hyphenation of TLC / HPTLC and MS The

More information

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector application Note UHPLC Author Njies Pedjie PerkinElmer, Inc. Shelton, CT 06484 USA Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector Introduction Foods

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2014, 5(5):91-98 ISSN: 0976-8688 CODEN (USA): PSHIBD A novel RP-HPLC method development and validation of Perindopril Erbumine in

More information

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40 International Research Journal of Pharmaceutical and Applied Sciences Available online at www.irjpas.com Int. Res J Pharm. App Sci., 2012; 2(4):35-40 Research Article Estimation of Fesoterodine fumarate

More information

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Development and validation of liquid chromatographic method for trazodone hydrochloride

Development and validation of liquid chromatographic method for trazodone hydrochloride Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2012, 4 (6):1657-1664 (http://scholarsresearchlibrary.com/archive.html) ISS 0975-5071 USA CODE: DPLEB4

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION DOI: 10.1038/NCHEM.2419 Diversification of Self-Replicating Molecules Jan W. Sadownik, Elio Mattia, Piotr Nowak, Sijbren Otto* University of Groningen, Center for Systems Chemistry, Stratingh Institute

More information

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is

More information

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 643 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia

More information

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Identification of Steroids in Water by Ion Trap LC/MS/MS Application Identification of Steroids in Water by Ion Trap LC/MS/MS Application Environmental Author Paul Zavitsanos and Christine Miller Agilent Technologies, Inc. Centerville Road Wilmington, DE 9- USA Abstract

More information

Supporting information

Supporting information Supporting information Figure legends Supplementary Table 1. Specific product ions obtained from fragmentation of lithium adducts in the positive ion mode comparing the different positional isomers of

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent

More information

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics Quantitative Analysis of piates in Urine Using RRHT LC/MS/MS Application Forensics Authors Sheher Mohsin Agilent Technologies, Inc. 10 N. Martingale Rd., Suite 550 Schaumburg, IL 60173 USA Yanan Yang Agilent

More information

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer APPLICATION NOTE 72819 Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer Author Maria Grübner; Thermo Fisher Scientific, Germering,

More information

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method International Journal of Chemical and Pharmaceutical Sciences 2017, Mar., Vol. 8 (1) ISSN: 0976-9390 IJCPS Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by

More information

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination Ozonolysis of phospholipid double bonds during electrospray ionization: a new tool for structure determination Michael C. Thomas, Todd W. Mitchell, Stephen J. Blanksby Departments of Chemistry and Biomedical

More information

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Larry T. Taylor, 1 Jinchuan Yang, 2 and Giorgis Isaac 2 1 Department of

More information

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc., PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES DR. A. RAMESH, Ph.D, D.Sc., raamesh_a@yahoo.co.in 1 OBJECTIVES Determination of persistence and photolysis

More information

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection APPLICATION NOTE Liquid Chromatography Author: Wilhad M. Reuter PerkinElmer, Inc. Shelton, CT Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection Introduction Cannabis sativa, from which

More information

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation PO-CON69E Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation MSACL 6 EU Stéphane Moreau, Daisuke Kawakami, Toshikazu Minohata Shimadzu Europe GmbH, Duisburg,

More information

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application Pharmaceutical Author Cliff Woodward Agilent Technologies, Inc. 285 Centerville

More information

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE WORLD JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES Ramalakshmi et al. SJIF Impact Factor 6.647 Volume 7, Issue 2, 1010-1018 Research Article ISSN 2278 4357 METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC

More information

Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard with Emphasize on Specificity Parameter Method

Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard with Emphasize on Specificity Parameter Method ISSN: 0970-020 X; CODEN: OJCHEG Oriental Journal of Chemistry 2011, Vol. 27, No. (2): Pg. 697-701 http://www.orientjchem.org Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard

More information

Authors. Abstract. Introduction. Environmental

Authors. Abstract. Introduction. Environmental Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,

More information

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses Ensuring High ensitivity and Consistent Response in UHPLC-M Analyses Markus Martin, Michael Heidorn, Frank teiner, Tobias Fehrenbach, and Fraser McLeod, Dionex Corporation, Germering, Germany Introduction

More information

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16 Asian Journal of Pharmaceutical Technology & Innovation ISSN: 2347-8810 Research Article Received on: 30-03-2016 Accepted on: 01-04-2016 Published on: 15-04-2016 Corresponding Author: *Pankti M. Shah,

More information

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: Research Article CODEN: AJPAD7 ISSN: 2321-0923 Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: www.ajpamc.com ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF GEFITINIB

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Title Revision n date

Title Revision n date A. THIN LAYER CHROMATOGRAPHIC TECHNIQUE (TLC) 1. SCOPE The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate and triamcinolone acetonide

More information

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol. 3, No.2, pp 605-609, April-June 2011 RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem

More information

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni Journal of Food Research; Vol. 4, No. 2; 2015 ISSN 1927-0887 E-ISSN 1927-0895 Published by Canadian Center of Science and Education Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides

More information

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract JJC Jordan Journal of Chemistry Vol. 4 No.4, 2009, pp. 357-365 Development and Validation of Analytical Method for Fluconazole and Fluconazole Related Compounds (A, B, and C) in Capsule Formulations by

More information

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 6(4), 2008, 2055-2061 DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS B. S. SASTRY a, S. GANANADHAMU and G. DEVALA RAO K. V.

More information