Intermittent Epidural Bolus Compared with Continuous Epidural Infusions for Labor Analgesia: A Systematic Review and Meta-Analysis

Size: px
Start display at page:

Download "Intermittent Epidural Bolus Compared with Continuous Epidural Infusions for Labor Analgesia: A Systematic Review and Meta-Analysis"

Transcription

1 Intermittent Epidural Bolus Compared with Continuous Epidural Infusions for Labor Analgesia: A Systematic Review and Meta-Analysis Ronald B. George, MD, FRCPC, * Terrence K. Allen, MBBS, FRCA, and Ashraf S. Habib, MB, ChB, MSc, MHS, FRCA BACKGROUND: The current standard labor epidural analgesic regimens consist of a local anesthetic in combination with an opioid delivered via continuous epidural infusion (CEI). With CEI local anesthetic, doses may be large with resulting profound motor blockade potentially affecting the incidence of instrumental deliveries. In this systematic review of randomized controlled trials (RCTs), we compared the effect of intermittent epidural bolus (IEB) to standard CEI dosing with or without patient-controlled epidural analgesia on patient satisfaction, the need for manual anesthesia interventions, labor progression, and mode of delivery in healthy women receiving labor epidural analgesia. METHODS: A systematic review of RCTs that compared CEI with IEB for labor analgesia was performed. The articles were evaluated for validity, and data were extracted by the authors and summarized using odds ratios (ORs), mean differences (MDs), and 95% confidence intervals (CIs). RESULTS: Nine RCTs were included in this systematic review. Three hundred forty-four subjects received CEI, whereas 350 subjects received IEB labor analgesia. All 9 studies were deemed to be low risk of bias. There was no statistical difference detected between IEB and CEI in the rate of cesarean delivery (OR, 0.87; 95% CI, ), duration of labor (MD, 17 minutes; 95% CI, 42 to 7), or the need for anesthetic intervention (OR, 0.56; 95% CI, ). IEB did result in a small but statistically significant reduction in local anesthetic usage (MD, 1.2 mg bupivacaine equivalent per hour; 95% CI, 2.2 to 0.3). Maternal satisfaction score (100-mm visual analog scale) was higher with IEB (MD, 7.0 mm; 95% CI, ). CONCLUSIONS: IEB is an appealing concept; current evidence suggests IEB slightly reduces local anesthetic usage and improves maternal satisfaction. Given the wide CIs of the pooled results for many outcomes, definite conclusions cannot be drawn for those outcomes, but there is also a potential that IEB improves instrumental delivery rate and need of anesthesia interventions. More study is required to conceptualize the ideal IEB regimen and investigate its effect on labor analgesia and obstetric outcomes. (Anesth Analg 2013;116:133 44) Childbirth is arguably one of the most painful experiences a woman can undergo. 1 The degree of pain experienced and the quality of pain relief affect patients satisfaction with the birthing process and may have long-term emotional and psychological effects. 2 The quality of labor neuraxial analgesia has surpassed parenteral opioids, nitrous oxide, and nonpharmacologic measures, with limited effect on the mode of delivery and maternal and neonatal outcomes. 3 From the *IWK Health Centre, Dalhousie University, Halifax, Nova Scotia, Canada; Division of Women s Anesthesia, Duke University Medical Center, Durham; and Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina. Accepted for publication August 14, Reprints will not be available from the authors. Dr. George acknowledges the Canadian Anesthesiologists Research Foundation for the 2011 CAS Career Scientist Award in Anesthesia. The authors declare no conflicts of interest. This report was previously presented, in part, at the Society of Obstetric Anesthesia and Perinatology Annual Meeting 2011, Canadian Anesthesiologists Society Annual Meeting Address correspondence to Ronald B. George, MD, FRCPC, Department of Women and Obstetric Anesthesia, IWK Health Centre, Dalhousie University, 5850/5980 University Avenue, PO Box 9700, Halifax, NS, Canada B3K 6R8. Address to rbgeorge@dal.ca. Copyright 2012 International Anesthesia Research Society DOI: /ANE.0b013e b26 The current standard labor epidural analgesic regimens in many institutions in North America and Europe consist of a local anesthetic in combination with an opioid delivered via continuous epidural infusion (CEI) with or without patient-controlled epidural analgesia (PCEA) boluses. Despite improved analgesia with CEI with or without PCEA compared with nonneuraxial analgesia, local anesthetic doses may be large with resulting profound motor blockade. 4 This reduces mobility, pelvic muscle tone, and may impair the ability to bear down during the second stage of labor, potentially resulting in increased rates of dystocia and instrumental deliveries. 5 In the continuing evolution of labor analgesia, rather than delivering the local anesthetic continuously, small regularly spaced intermittent boluses may lead to a more extensive spread of local anesthetic in the epidural space. 6 Therefore, the same dose of local anesthetic given via intermittent epidural bolus (IEB) may provide improved analgesia. Research into IEB is growing, and medical devices are in development. A shift in current practice from CEI (with or without PCEA) to IEB (with or without PCEA) will require enhanced pump technology and acceptance by obstetric anesthesiologists to justify the cost of pump replacement to hospital administration. Previous systematic reviews have addressed labor epidural analgesia versus no analgesia and alternate forms of neuraxial analgesia. 7 9 van der Vyver January 2013 Volume 116 Number

2 Intermittent Epidural Bolus: A Systematic Review et al. 10 systematically reviewed traditional PCEA versus CEI; however, their study was published in 2002, before the use of IEB dosing. We, therefore, performed this systematic review of randomized controlled trials (RCTs) to compare the effects of IEB to standard CEI dosing with or without PCEA in healthy women receiving labor epidural analgesia. Specifically, we investigated whether IEB compared with CEI affects patient satisfaction, the need for manual anesthesia interventions, labor progression, and mode of delivery. METHODS The current meta-analysis adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for reporting meta-analyses. 11 The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (PubMed), Excerpta Medica Database (EMBASE), Cumulative Index to Nursing and Allied Health Literature (CINAHL), and the Web of Science (Science Citation Index/ Social Science Citation Index [SCI/SSCI]) were searched. CENTRAL, EMBASE, CINAHL, and SCI/SSCI were last searched in July The PubMed search was last updated on July 4, MeSH terms relating to labor analgesia and neuraxial anesthetic techniques (analgesia, epidural; anesthesia, obstetrical; pregnancy; analgesia, patient-controlled) were combined with text searches for intermittent and automated and relevant synonyms. The results of these searches were combined with a sensitive methodologic filter for RCTs found in Section of the Cochrane Handbook for Systematic Reviews of Interventions. 12 No restrictions, other than those intrinsic to the database being searched, were placed on the dates of publication. The reference lists from retrieved RCTs were screened to identify additional trials, as were recent tables of contents for the leading anesthesia journals. a A search by author for any individual who appears as an author on 2 or more relevant articles was completed. Using PubMed s See related articles function with relevant trials, additional references were sought. In addition, citation records for all relevant RCTs were searched and reviewed with SCI/SSCI. No restrictions with respect to language were included. Unpublished meeting abstracts were not searched, only published RCTs were sought. An attempt was made to contact authors regarding any clarification of primary outcome measures; unpublished data were not requested. Study Identification The types of studies considered for this review included all published RCTs involving a comparison of IEB dosing for maintenance of labor epidural analgesia compared with traditional CEI dosing with or without PCEA. Specifically, participants were healthy laboring women (nulliparous and parous) with lumbar epidural catheters placed for labor analgesia (induced or spontaneous). Primary outcomes analyzed included patient satisfaction, anesthesia interventions, labor progression, and mode of delivery (vaginal, a January 1, 2012, to July 4, 2012 International Journal of Obstetric Anesthesia, Anesthesia & Analgesia, Anesthesiology, Canadian Journal of Anesthesia, Anaesthesia, and British Journal of Anaesthesia. instrumental vaginal, or cesarean delivery [CD]). Secondary outcomes included degree of motor blockade, degree of sensory blockade, time to first anesthetic intervention, local anesthetic dose delivered per hour, presence of pruritus, shivering, maternal fever, nausea and vomiting, neonatal Apgar scores at 1 minute and 5 minutes, and umbilical artery and vein ph. Studies were included if they reported any of the primary outcomes. Disagreements regarding inclusion of potentially eligible trials were resolved by discussion and, if necessary, arbitration by a third reviewer. Data Extraction and Assessment Data were extracted independently by 2 authors (RG and AH). No predesigned data sheet was used. When data were presented as medians, ranges, and confidence intervals (CIs), the mean and standard deviations were calculated as per Hozo et al. 13 Two reviewers (RG and TA) independently assessed the quality (i.e., risk of bias) of all included studies using criteria adapted from Furlan et al. 14 Each of the 12 criteria were scored as yes, no, or unclear. Studies that met 6 of the criteria were rated as having a low risk of bias. In the event that discussion was unable to solve a disagreement between the 2 reviewers, the opinion of the third reviewer (AH) was sought. An a priori sensitivity analysis was planned excluding studies with high risk of bias. Epidural dose calculations were calculated from summarized data by dividing total dose delivered by the mean duration of labor or duration of analgesia delivery reported in each study. Local anesthetic doses were converted to milligram equivalents of bupivacaine per hour of anesthesia delivery. Ropivacaine and levobupivacaine were assumed to be approximately 60% as potent as bupivacaine All data pertaining to the predetermined outcome measures were transcribed to RevMan 5 for meta-analysis (Version 5.1. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2011). If meta-analytic methods were not possible, the data were simply presented qualitatively. All data were analyzed using a random-effects model due to clinical or methodologic heterogeneity. Continuous variables were reported as mean difference (MD) with 95% CI, while dichotomous data were reported as odds ratios (OR) with 95% CI. Heterogeneity was assessed with the I 2 statistic that describes the percentage of variation across studies that is due to heterogeneity rather than chance. 18 A P < 0.1 was considered statistically significant heterogeneity, and I 2 > 50% was considered to indicate significant heterogeneity. Heterogeneity was explored by performing a sensitivity analysis excluding outlier studies if they were methodologically different from other studies. Publication bias was formally assessed with the Egger test. 19 RESULTS The results of the literature search are outlined in Figure 1. After screening, 21 articles were selected for in-depth fulltext review, from which 9 articles were deemed eligible for inclusion in this systematic review The 12 excluded citations clearly did not include a randomized comparison of IEB dosing of a labor epidural compared with standard CEI Three hundred forty-four subjects received CEI, while 350 subjects received IEB labor analgesia. Study characteristics and risk of bias assessment are included in ANESTHESIA & ANALGESIA

3 Figure 1. Manuscript selection flow diagram. Tables 1 and 2. All 9 studies were deemed low risk of bias. Spontaneous onset of labor was an inclusion criteria in 4 studies. 20,21,24,27 However, 3 of the 4 studies reported a percentage of women who received preanalgesia oxytocin. 21,24,27 Two studies reported the portion of women whose labor was induced. 22,26 Wong et al. 28 only recruited parous women for induction of labor. Two studies reported the preanalgesia use of oxytocin. 23,25 Mode of Delivery Of the 9 included trials, 8 reported data on the mode of delivery. These 8 studies included 652 subjects. 20,22 28 None of the studies reported a significant difference in the CD rate. Pooled results also did not show a difference in the rate of CD (OR, 0.87; 95% CI, ; Fig. 2). Similarly, none of the studies reported a reduction in instrumental delivery rate except the study by Capogna et al. 20 This was the only study designed and powered to detect a difference in instrumental delivery rates and reported a significant reduction with IEB compared with CEI (7% vs 20%; P = 0.03). 20 The pooled results for these 8 studies approached but did not achieve statistical significance with reduction of instrumental delivery rate with IEB (OR, 0.59; 95% CI, ; Fig. 3). Wong et al. 28 recruited only parous women, while the other studies contained only nulliparous women. Excluding the study by Wong et al. 28 had no effect on pooled results (cesarean delivery OR, 0.85; 95% CI, ; instrumental delivery OR, 0.57; 95% CI, ). There was no publication bias for CD (P = 0.27) or instrumental delivery (P = 0.48). Duration of Labor Of the 9 included studies, 8 reported the total duration of labor or duration of labor analgesia (n = 652), 20,22 28 while only 5 reported the duration of the second stage of labor (n = 321) ,26,27 There was no statistically significant difference in total duration of labor between IEB and CEI (Fig. 4A). The duration of second stage of labor was statistically significantly shortened in the IEB group (MD, 12 minutes; 95% CI, 23 to 0; Fig. 4B). There was no publication bias for duration of labor (P = 0.06) or second stage of labor (P = 0.82). Anesthesia Interventions Of the 9 included trials, 8 reported data on the need for manual boluses of local anesthetic by the anesthesia caregiver ,27,28 These 8 studies included 567 subjects (Fig. 5). Capogna et al. 20 reported that no subjects in either group required an anesthetic intervention. There was no statistically significant reduction in the need for additional anesthetic intervention (OR, 0.56; 95% CI, ). The time to a subject s first anesthetic intervention was not significantly January 2013 Volume 116 Number

4 Intermittent Epidural Bolus: A Systematic Review Table 1. Study Characteristics and Risk of Bias Assessment of Included Studies Study n Parity Combined spinal epidural subarachnoid medications Epidural solution CEI regimen IEB regimen Capogna et al Nulliparous N/A Levobupivacaine, % 0.125%; sufentanil, 0.5 µg/ml Chua and Sia Nulliparous Fentanyl, 25 µg Ropivacaine, 0.1%; fentanyl, 2 µg/ml Fettes et al Nulliparous N/A Ropivacaine, 0.2%; fentanyl, 2 µg/ml Leo et al Nulliparous Ropivacaine, 2 mg; fentanyl, 15 µg Ropivacaine 0.1%; fentanyl 2 µcg/ml Lim et al Nulliparous Fentanyl, 25 µg Levobupivacaine, 0.1%; fentanyl, 2 µg/ml Lim et al Nulliparous Ropivacaine, 2 mg; fentanyl, 15 µg Ropivacaine, 0.1%; fentanyl, 2 µg/ml Salim et al Nulliparous N/A Bupivacaine, 0.125% 0.25%; fentanyl, 2 µg/ml Sia et al Nulliparous Ropivacaine, 2 mg; fentanyl, 15 µg Wong et al Parous Bupivacaine, 1.25 mg; fentanyl, 15 µg Ropivacaine, 0.1%; fentanyl, 2 µg/ml Bupivacaine, 0.625%; fentanyl 2, µg/ml 10 ml/h (0.0625%) + PCEA (5 ml bolus, 10 minute lockout, 0.125%) (n = 70) 10 ml (0.0625%) bolus every hour + PCEA (5 ml bolus, 10 minute lockout, 0.125%) (n = 75) Spontaneous/induced labor, n (%) Spontaneous labor a ; oxytocin use not reported 5 ml/h (n = 21) 5 ml bolus every hour (n = 21) Spontaneous labor a ; preanalgesia oxytocin; CEI, 8 (38); IEB, 9 (43) 10 ml/h (n = 20) 10 ml bolus every hour (n = 20) Induction of labor; CEI, 12 (60); IEB, 14 (70) 5 ml/h + PCEA (5 ml bolus, 10 minute lockout) (n = 31) 5 ml bolus every hour (or 30 minutes after successful PCEA dose) + PCEA (5 ml bolus, 10 minute lockout) (n = 31) 10 ml/h (n = 30) 5 ml bolus every 30 minutes (n = 30) 10 ml/h (n = 25) 2.5 ml bolus every 15 minutes 8 ml/h (0.125%) + PCEA (3 ml bolus, 20 minute lockout) (n = 63) 5 ml/h + PCEA (5 ml bolus, 10 minute lockout) (n = 21) 12 ml/h + PCEA (5 ml bolus, 10 minute lockout) (n = 63) (initiated 7.5 minutes after SA dose) (n = 25) 10 ml bolus every hour (0.25%) (n = 64) 5 ml bolus every hour (or 1 hour after successful PCEA dose) (n = 21) 6 ml bolus every 30 minutes + PCEA (5 ml bolus, 10 minute lockout) (n = 63) Preanalgesia oxytocin; CEI, 10 (32); IEB, 15 (48) Preanalgesia oxytocin; CEI, 4 (13); IEB, 9 (30) Spontaneous labor a ; preanalgesia oxytocin; CEI, 10 (40); IEB, 5 (20) Induction of labor; CEI, 17 (27); IEB, 14 (22) Spontaneous labor a ; preanalgesia oxytocin; CEI, 5 (24); IEB, 7 (33) Induction of labor a ; CEI, 63 (100); IEB; 63 (100) CEI = continuous epidural infusion; IEB = intermittent epidural bolus; PCEA = patient-controlled epidural analgesia; SA = subarachnoid. a Reported as an inclusion criteria. Risk of bias assessment ANESTHESIA & ANALGESIA

5 Table 2. The Risk of Bias of Included Studies 14 Capogna et al. 20 Chua and Sia 21 Fettes et al. 22 Leo et al. 23 Lim et al. 25 Lim et al. 24 Salim et al. 26 Sia et al. 27 Wong et al. 28 Was the method of randomization adequate? Yes No Yes No No Yes Yes Yes Yes Was the treatment allocation concealed? Yes Yes Yes Yes No Yes Yes Yes Yes Was the patient blinded to the intervention? Yes Yes Yes Yes No Yes Unsure Yes Yes Was the care provider blinded to the intervention? Yes Yes Yes Yes Unsure Yes Unsure Yes Yes Yes Yes Yes Yes Yes Yes Unsure Yes Yes Was the outcome assessor blinded to the intervention? Was the dropout rate described and acceptable? Yes Yes Yes Yes Yes Yes Yes Yes Yes Were all randomized participants analyzed in their Yes Yes Yes Yes Yes Yes Yes Yes Yes allocated group? Are reports of the study free of suggestion of Yes Yes Yes Yes Yes Yes No Yes Yes selective outcome reporting? Were the groups similar at baseline? Yes Yes Yes Yes Yes Yes Yes Yes Yes Were cointerventions avoided or similar? Yes Yes Yes Yes Yes Yes Yes Yes Yes Was the compliance acceptable in all groups? Yes Yes No Yes Yes Yes Yes Yes No Was the timing of the outcome assessment similar? Yes Yes Yes Yes Yes Yes Yes Yes Yes different between groups (MD, 17 minutes; 95% CI, 28 to 62; Fig. 6). Significant heterogeneity was observed for the time to first interventions outcome (I 2 = 74%). Chua et al. 21 appear to add significant heterogeneity to this analysis. Removing this study abolishes this heterogeneity (I 2 = 0%) with no effect on pooled results (MD, 7 minutes; 95% CI, 37 to 24). Wong et al. 28 and Sia et al. 27 did not report time to first anesthesia intervention. Sia et al., 27 reported no significant difference in the pain-free interval between CEI and IEB. Wong et al. 28 did report the time to first PCEA usage, and this was not significantly different between the IEB and CEI groups. There was no publication bias for manual interventions (P = 0.57) or time to intervention (P = 0.15). Dose of Local Anesthetic The specific regimens and local anesthetic concentrations are listed in Table 1. Of the 9 included studies, 3 published data regarding the total dose of local anesthetic per hour during the study period. 23,24,28 Five other studies 20,22,25 27 reported the total dose given. The study of Chua et al. 21 was not included in this analysis because the study concluded with the first need for anesthetic intervention. With these 8 studies (n = 652) there was a statistically significant reduction in total local anesthetic delivered with IEB (MD, 1.2 mg bupivacaine equivalents per hour; 95% CI, 2.2 and 0.3; I 2 = 83%; Fig. 7A). Salim et al. 26 used a concentrated local anesthetic mixture for their IEB group, different from their CEI group; therefore, we performed a sensitivity analysis excluding this study. The effect was smaller but still statistically significant in favor of IEB with less heterogeneity (MD, 0.7 mg/h; 95% CI, 1.2 to 0.2; I 2 = 40%; Fig. 7B). There was no publication bias for local anesthetic consumption (P = 0.26). Maternal Satisfaction Overall maternal satisfaction with labor analgesia was reported in 5 of the included studies ,27,28 Four studies reported maternal satisfaction with a verbal rating scale (VRS) where 0 is very dissatisfied and 100 is extremely satisfied ,27 Wong et al. 28 reported maternal satisfaction with a 100-mm visual analog scale (VAS) score. Pooled data from the 5 studies showed greater maternal satisfaction in the IEB groups (MD, 7.0 mm; 95% CI, ; Fig. 8). Exclusion of the study by Wong et al. 28 did not have a significant effect on the pooled results (MD, 7.1 mm; 95% CI, ). There was no publication bias for maternal satisfaction (P = 0.84). Subgroup Analysis of Primary Outcomes Each of the primary outcomes had a subgroup analysis completed based on: (1) the use of a combined spinal epidural (CSE) technique to initiate labor analgesia and (2) the use of PCEA during maintenance of labor analgesia. Five studies initiated analgesia with a CSE. 21,23 25,27 The initiation of labor analgesia with a CSE did not have a significant effect on any of the primary outcomes. The use of PCEA for maintenance of labor analgesia made a noteworthy effect on the duration of the first stage of labor and the total duration of labor. When PCEA was used for maintenance of labor, the duration of first stage was longer with IEB 23,26,27 (MD, 20 minutes; 95% CI, 22 to 61). However, when PCEA was not used for maintenance of labor, the duration of first stage January 2013 Volume 116 Number

6 Intermittent Epidural Bolus: A Systematic Review Figure 2. Forest plot for mode of delivery (cesarean). CEI = continuous epidural infusion; IEB = intermittent epidural bolus. Figure 3. Forest plot for mode of delivery (instrumental). CEI = continuous epidural infusion; IEB = intermittent epidural bolus. was shorter with IEB 22,24 (MD, 61 minutes; 95% CI, 129 to 6; Fig. 9). The total duration of labor was reduced with IEB when PCEA was not used 22,24,25 (MD, 86 minutes; 95% CI, 146 to 27), but not when it was used 20,23,26 28 (MD, 4 minutes; 95% CI, 26 to 17; Fig. 4A). Additional Outcomes Other than dose of local anesthetic, most of the secondary outcomes were infrequently reported. A meta-analysis was completed on specific outcomes that contained data from more than 1 study. There were no significant differences between the groups with respect to these outcomes. The results are summarized in Table 3. Umbilical ph values and 1-minute Apgar scores were only reported in 1 study (no significant difference). 22 The 5-minute Apgar was reported in 4 studies, in which the MD was 0.04 with a 95% CI of 0.2 to 0.1. The degree of sensory block was quantified in 4 studies. Leo et al. 23 and Lim et al. 24 reported the sensory block level at the first request for additional analgesia. Chua et al. 21 reported the maximal sensory block level within the first 3 hours of analgesia, while Sia et al. 27 reported the maximal sensory block during the entire study period. Within these studies, there was no significant difference between CEI and IEB with respect to sensory blockade. Capogna et al. 20 designed their study to detect a clinically significant degree of motor blockade measured with the Bromage score modified by Breen et al. 41 In their study, the incidence of motor block (defined as modified Bromage score 41 <6, i.e., the inability to stand and complete a partial knee bend) at least once during labor was significantly increased in the CEI group compared with the IEB group (26/70 vs 2/75, P < 0.001). Assuming the modified Bromage score <6 20 is equivalent to a traditional Bromage score >1, 21,27,28 then the pooled results are not statistically significant (Table 3). DISCUSSION Nine high-quality low risk of bias RCTs have evaluated IEB versus CEI in laboring women. In healthy women requesting labor epidural analgesia, the mode of maintenance of epidural analgesia may not affect the mode of delivery. However, intermittent bolus dosing of local anesthetic may be associated with reduced local anesthetic consumption, decreased anesthetic interventions, and an improvement in maternal satisfaction when compared with those women receiving CEI. The 2 techniques of local anesthesia delivery appear to be comparable in terms of total duration of labor, but there was a statistically significant reduction in the length of the second stage of labor with IEB. The duration of the second stage was a much as 22 minutes shorter with IEB. Arguably, this may enter the realm of clinically significant, ANESTHESIA & ANALGESIA

7 Figure 4. A, Forest plot for the total duration (minutes) of labor and the subgroup analysis for patient-controlled epidural analgesia (PCEA) maintenance of labor analgesia. B, Forest plot for the duration (minutes) of second stage of labor. CEI = continuous epidural infusion; IEB = intermittent epidural bolus. Figure 5. Forest plot for required anesthetic interventions. CEI = continuous epidural infusion; IEB = intermittent epidural bolus. and IEB may positively affect labor progression. Although there was no statistically significant difference between the 2 groups with regard to the incidence of adverse events (Table 3), the wide CIs of the pooled results preclude us from making any conclusions. Despite not reaching statistical significance, several outcomes should be considered potentially clinically significant. The pooled results for instrumental delivery rate, rate of anesthetic interventions, and duration of labor each have wide CIs that contain clinically significant end points, therefore precluding us from drawing conclusions from the pooled data for those outcomes. For instance the lower end CI for the OR for instrumental delivery is 0.35, a clinically significant possibility with IEB. With a January 2013 Volume 116 Number

8 Intermittent Epidural Bolus: A Systematic Review Figure 6. Forest plot for time (minutes) to first required anesthetic intervention. CEI = continuous epidural infusion; IEB = intermittent epidural bolus. Figure 7. A and B, Forest plot for milligrams per hour of local anesthetic (bupivacaine equivalents) delivered. CEI = continuous epidural infusion; IEB = intermittent epidural bolus. Figure 8. Forest plot for maternal satisfaction (visual analog scale [VAS] mm; verbal rating scale [VRS] 23 25, ; 0 = very dissatisfied, 100 = extremely satisfied). CEI = continuous epidural infusion; IEB = intermittent epidural bolus ANESTHESIA & ANALGESIA

9 Figure 9. Forest plot for the duration (minutes) of first stage of labor and the subgroup analysis for patient-controlled epidural analgesia (PCEA) maintenance of labor analgesia. CEI = continuous epidural infusion; IEB = intermittent epidural bolus. Table 3. Secondary Outcomes Outcome Studies Nausea Lim et al. 24,25 Sia et al. 27 Leo et al. 23 Vomiting Lim et al. 24,25 Sia et al. 27 Leo et al. 23 Pruritus Lim et al. 24,25 Sia et al. 27 Leo et al. 23 Hypotension Lim et al. 24,25 Sia et al. 27 Fettes et al. 22 Chua et al. 21 Leo et al. 23 Motor blockade Chua et al. 21 Sia et al. 27 Wong et al. 28 Capogna et al. 20 Number of events/total in intermittent epidural bolus group Number of events/total in continuous epidural infusion group Odds ratio (95% confidence interval) 10/107 (9.3%) 3/107 (2.8%) 2.83 ( ) 9/107 (8.4%) 3/107 (2.8%) 3.21 ( ) 62/107 (57.9%) 62/107 (57.9%) 1.00 ( ) 7/148 (4.7%) 3/148 (2.0%) 1.70 ( ) 5/180 (2.8%) 28/175 (16.0%) 0.47 ( ) heterogeneity measure of zero, 8 studies contributing to a very close statistical significance (P = 0.05) and an absolute risk difference of 5.2% suggest a number-needed-to-treat of 20 to prevent 1 instrumental delivery. The effect size of 0.59 suggests that future trials of IEB should include approximately 486 participants (G-Power v , Mannheim, Germany) to show a statistically significant reduction in the instrumental delivery rate compared with standard CEI. 42 Induced versus spontaneous labor is a potential factor in these important outcomes; however, not all studies restricted the inclusion criteria nor specifically reported this event; therefore, a subgroup analysis was not possible. Interference with normal labor progression leading to instrumental deliveries is a potentially unfavorable outcome of labor analgesia. However, modern labor analgesia with low concentrations of local anesthetics can be administered without adversely affecting labor outcomes. 42 In the Comparative Obstetric Mobile Epidural Trial (COMET) conducted in the United Kingdom, Wilson et al. 43 demonstrated that despite improved analgesia and lower doses of local anesthetic in the CSE analgesia arm of the study, this technique did not alter delivery modality or duration of labor. Despite the lack of statistical significance to alter labor outcomes with IEB delivery of epidural analgesia, the improvement in maternal satisfaction, which may loosely reflect improved analgesia, is still an important goal for labor analgesia research. Satisfaction with labor analgesia is an important outcome of the quality of care given to women. It is a complex measure commonly used to describe overall adequacy of pain relief. However, maternal satisfaction involves many factors maternal involvement in decision making, perception of emotional control, maternal expectations, and labor pain Furthermore, labor pain is more than a simple physiological process; it is a complex reaction for which inadequately validated measures of maternal satisfaction, such as VAS and VRS measures, may or may not necessarily correlate to the effectiveness of pain relief. 47,48 Given the complexity January 2013 Volume 116 Number

10 Intermittent Epidural Bolus: A Systematic Review of measuring satisfaction, the different scales used, and the timing of such a measure, the lack of heterogeneity (I 2 = 0%) should be interpreted with caution. All of the studies had small sample sizes reflecting the difference in the outcomes they were powered to detect. Two trials were powered to detect a difference in the dose of local anesthetic delivered. 27,28 A single study was powered to detect a difference in the duration of labor. 26 Fettes et al. 22 powered their study to detect a difference in VAS score at an arbitrary time, 4 hours after the intervention. Four studies were powered to detect a difference in need for anesthesia interventions. 21,23 25 Other than Capogna et al., 20 none of the included trials was powered to detect a difference in the side effects of labor analgesia. No studies were powered to detect a difference in maternal satisfaction. Capogna et al. 20 published the largest and most recent trial, which was powered to detect a difference in the incidence of motor blockade (primary outcome) and instrumental deliveries (secondary outcome). They reported a greater incidence of motor blockade with CEI using the modified Bromage score, which may be more sensitive than the traditional Bromage score. 41 The authors suggested that the greater incidence of motor blockade and subsequent higher instrumental delivery rate in the CEI group compared with other similar trials was due to the longer duration of observation in their study. However, the duration of labor was not significantly longer in this trial and was likely shorter than average. The dramatic decrease in instrumental delivery rate is likely related to the reduced motor blockade. Perhaps the CEI infusion that was started immediately after induction of analgesia or the increased number of patients who used the higher concentration 0.125% levobupivacaine PCEA option in the CEI group added significantly to the cumulative dose of levobupivacaine and subsequent increased motor blockade. The ultralow dose regimen for epidural analgesia based on the study by Capogna et al. 20 and the reduced PCEA use in the IEB group and subsequent reduced motor blockade appear to eloquently display a potential benefit of IEB. Whether it was the higher PCEA use in the CEI group or the characteristics of IEB with % levobupivacaine, they both seem to deliver appropriate analgesia, as neither group required a manual anesthetic intervention. This came at the cost of increased motor blockade and instrumental delivery in the CEI group. This review has several limitations. There was significant inconsistency with regard to reporting of outcomes. Each of the included studies reported at least 1 primary outcome, but none of the included studies included all primary outcomes reported in this systematic review. Each study, except Sia et al., 27 found at least 1 significant difference in a primary outcome measure. Measures of analgesia such as pain scores reported using VAS, VRS, or numeric rating scales were not measured at standard intervals. In contrast, maternal satisfaction was nearly consistently reported and may represent a surrogate measure of analgesia. The study by Wong et al. 28 was the only study to recruit parous subjects; in fact, they only included parturients with at least 1 previous vaginal delivery (126 subjects). The remaining studies only included uncomplicated nulliparous women. This likely limits our ability to extrapolate our conclusions to women presenting with multiple gestations and parous women. Because of the small number of studies, a metaregression was not conducted to control for factors known to affect the outcomes of interest. There was significant clinical heterogeneity among studies with regard to labor analgesia initiation, specific local anesthetic and concentration, and drug delivery regimens. A subgroup analysis of the effect of PCEA maintenance and CSE analgesia initiation yielded only a potential interaction between PCEA, IEB, and the duration of labor. Because of the small number of studies, the relatively youthful field of IEB, and the variety of analgesia regimens, sensitivity analysis of these dosing variables was not part of this analysis. Currently, because of IEB with PCEA equipment not being readily available, standardization of equipment among institutions is nearly impossible. Specifically, the dosing volumes and intervals varied among the studies, and it is unknown whether this influenced the reported outcomes. Much like the debates regarding the ideal regimen of CEI combined with PCEA, the search for the ideal IEB regimen is sure to inspire future studies. Wong et al. 49 have initiated this avenue of research. They recently compared 3 regimens of IEB and PCEA: 2.5 ml every 15 minutes, 5 ml every 30 minutes, and 10 ml every 60 minutes of mg/ml bupivacaine with 1.95 µg/ml of fentanyl. The 10/60 group did consume less bupivacaine, and the 2.5/15 group appeared to require more interventions for poor analgesia, but otherwise all 3 groups were very similar with respect to mode of delivery, PCEA usage, manual anesthesia interventions, pain scores, and motor blockade. Future studies will need to be powered to detect the small differences that may exist between the extremes of bolus size. Accepting that the lowdose epidural regimens of Wong et al. 49 and Capogna et al. 20 are likely near the ideal concentration, the trends suggest that larger volume boluses may be required. In summary, IEB may be associated with reduced local anesthetic consumption, shorter second stage of labor, and higher maternal satisfaction but possibly no difference in mode of delivery or required anesthetic interventions compared with CEI. As previously noted, the wide CIs for the pooled results of some of the reported outcomes do contain clinically significant differences, such as the potential for a clinically significant reduction in the instrumental delivery rate with IEB. Further research of IEB for labor analgesia is necessary before definite conclusions can be made. Current epidural pump technology does not allow using IEB with PCEA, and changing current practice would require a significant financial influx to labor wards for the required pump technology and education. On the basis of the findings of this systematic review and metaanalysis, current evidence suggests that there may be potential improvements in instrumental delivery rates and rates of anesthesia interventions, so more studies are required to conceptualize the ideal IEB/PCEA regimen and then consistently show an improvement in labor analgesia and a greater effect on obstetric outcomes. The new pump technology required for this new technique and the cost that this entails could easily be justified by improved outcomes. E ANESTHESIA & ANALGESIA

11 DISCLOSURES Name: Ronald B. George, MD, FRCPC. Contribution: This author helped design and conduct the study, analyze the data, and write the manuscript. Attestation: Ronald B. George has seen the original study data, reviewed the analysis of the data, approved the final manuscript, and is the author responsible for archiving the study files. Name: Terrence K. Allen, MBBS, FRCA. Contribution: This author helped conduct the study, analyze the data, and write the manuscript. Attestation: Terrence K. Allen has seen the original study data, reviewed the analysis of the data, and approved the final manuscript. Name: Ashraf S. Habib, MB, ChB, MSc, MHS, FRCA. Contribution: This author helped conduct the study, analyze the data, and write the manuscript. Attestation: Ashraf S. Habib has seen the original study data, reviewed the analysis of the data, and approved the final manuscript. This manuscript was handled by: Cynthia A. Wong, MD. REFERENCES 1. Melzack R. The myth of painless childbirth (the John J. Bonica lecture). Pain 1984;19: Lavand homme P. Chronic pain after vaginal and cesarean delivery: a reality questioning our daily practice of obstetric anesthesia. Int J Obstet Anesth 2010;19: Wong CA, Scavone BM, Peaceman AM, McCarthy RJ, Sullivan JT, Diaz NT, Yaghmour E, Marcus RJ, Sherwani SS, Sproviero MT, Yilmaz M, Patel R, Robles C, Grouper S. The risk of cesarean delivery with neuraxial analgesia given early versus late in labor. N Engl J Med 2005;352: Leighton BL, Halpern SH. The effects of epidural analgesia on labor, maternal, and neonatal outcomes: a systematic review. Am J Obstet Gynecol 2002;186:S Thornton JG, Capogna G. Reducing likelihood of instrumental delivery with epidural anaesthesia. Lancet 2001;358:2 6. Power I, Thorburn J. Differential flow from multihole epidural catheters. Anaesthesia 1988;43: Anim-Somuah M, Smyth R, Howell C. Epidural versus nonepidural or no analgesia in labour. Cochrane Database Syst Revar2005:CD Halpern SH, Carvalho B. Patient-controlled epidural analgesia for labor. Anesth Analg 2009;108: Simmons SW, Cyna AM, Dennis AT, Hughes D. Combined spinal epidural versus epidural analgesia in labour. Cochrane Database Syst Rev 2007:CD van der Vyver M, Halpern S, Joseph G. Patient-controlled epidural analgesia versus continuous infusion for labour analgesia: a meta-analysis. Br J Anaesth 2002;89: Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med 2009;151:264 9, W Lefebvre C, Manheimer E, Glanville J. Searching for studies. In: Higgins JP, Green S, eds. Cochrane Handbook for Systematic Reviews of Interventions Version The Cochrane Collaboration. Chichester, UK: John Wiley & Sons, Hozo SP, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 2005;5: Furlan AD, Pennick V, Bombardier C, van Tulder M; Editorial Board, Cochrane Back Review Group updated method guidelines for systematic reviews in the Cochrane Back Review Group. Spine 2009;34: Capogna G, Celleno D, Fusco P, Lyons G, Columb M. Relative potencies of bupivacaine and ropivacaine for analgesia in labour. Br J Anaesth 1999;82: Polley LS, Columb MO, Naughton NN, Wagner DS, van de Ven CJ. Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor: implications for therapeutic indexes. Anesthesiology 1999;90: Polley LS, Columb MO, Naughton NN, Wagner DS, van de Ven CJ, Goralski KH. Relative analgesic potencies of levobupivacaine and ropivacaine for epidural analgesia in labor. Anesthesiology 2003;99: Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med 2002;21: Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ 1997;315: Capogna G, Camorcia M, Stirparo S, Farcomeni A. Programmed intermittent epidural bolus versus continuous epidural infusion for labor analgesia: the effects on maternal motor function and labor outcome. A randomized double-blind study in nulliparous women. Anesth Analg 2011;113: Chua SM, Sia AT. Automated intermittent epidural boluses improve analgesia induced by intrathecal fentanyl during labour. Can J Anaesth 2004;51: Fettes PD, Moore CS, Whiteside JB, McLeod GA, Wildsmith JA. Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour. Br J Anaesth 2006;97: Leo S, Ocampo CE, Lim Y, Sia AT. A randomized comparison of automated intermittent mandatory boluses with a basal infusion in combination with patient-controlled epidural analgesia for labor and delivery. Int J Obstet Anesth 2010;19: Lim Y, Chakravarty S, Ocampo CE, Sia AT. Comparison of automated intermittent low volume bolus with continuous infusion for labour epidural analgesia. Anaesth Intensive Care 2010;38: Lim Y, Sia AT, Ocampo C. Automated regular boluses for epidural analgesia: a comparison with continuous infusion. Int J Obstet Anesth 2005;14: Salim R, Nachum Z, Moscovici R, Lavee M, Shalev E. Continuous compared with intermittent epidural infusion on progress of labor and patient satisfaction. Obstet Gynecol 2005;106: Sia AT, Lim Y, Ocampo C. A comparison of a basal infusion with automated mandatory boluses in parturient-controlled epidural analgesia during labor. Anesth Analg 2007;104: Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg 2006;102: Gambling DR, McMorland GH, Yu P, Laszlo C. Comparison of patient-controlled epidural analgesia and conventional intermittent top-up injections during labor. Anesth Analg 1990;70: Halonen P, Sarvela J, Saisto T, Soikkeli A, Halmesmäki E, Korttila K. Patient-controlled epidural technique improves analgesia for labor but increases cesarean delivery rate compared with the intermittent bolus technique. Acta Anaesthesiol Scand 2004;48: Hicks JA, Jenkins JG, Newton MC, Findley IL. Continuous epidural infusion of 0.075% bupivacaine for pain relief in labour. A comparison with intermittent top-ups of 0.5% bupivacaine. Anaesthesia 1988;43: Hopp H, Schmitz P, Heinrich J. [Continuous peridural anesthesia results of fractionated application in comparison to catheter infusion]. Z Geburtshilfe Perinatol 1982;186: Lamont RF, Pinney D, Rodgers P, Bryant TN. Continuous versus intermittent epidural analgesia. A randomised trial to observe obstetric outcome. Anaesthesia 1989;44: Li DF, Rees GA, Rosen M. Continuous extradural infusion of % or 0.125% bupivacaine for pain relief in primigravid labour. Br J Anaesth 1985;57: Nikkola E, Läärä A, Hinkka S, Ekblad U, Kero P, Salonen M. Patient-controlled epidural analgesia in labor does not always improve maternal satisfaction. Acta Obstet Gynecol Scand 2006;85: January 2013 Volume 116 Number

12 Intermittent Epidural Bolus: A Systematic Review 36. Paech MJ, Pavy TJ, Sims C, Westmore MD, Storey JM, White C. Clinical experience with patient-controlled and staff-administered intermittent bolus epidural analgesia in labour. Anaesth Intensive Care 1995;23: Robert D, Kaladji C, Charlet P, Soufarapis H, Quesnel J, Bricard H. [Peridural obstetrical anesthesia: intermittent injections or perfusion of bupivacaine?]. Cah Anesthesiol 1989;37: Smedstad KG, Morison DH. A comparative study of continuous and intermittent epidural analgesia for labour and delivery. Can J Anaesth 1988;35: Vandermeulen EP, Van Aken H, Vertommen JD. Labor pain relief using bupivacaine and sufentanil: patient controlled epidural analgesia versus intermittent injections. Eur J Obstet Gynecol Reprod Biol 1995;59 Suppl:S Vertommen JD, Lemmens E, Van Aken H. Comparison of the addition of three different doses of sufentanil to 0.125% bupivacaine given epidurally during labour. Anaesthesia 1994;49: Breen TW, Shapiro T, Glass B, Foster-Payne D, Oriol NE. Epidural anesthesia for labor in an ambulatory patient. Anesth Analg 1993;77: Halpern SH, Abdallah FW. Effect of labor analgesia on labor outcome. Curr Opin Anaesthesiol 2010;23: Wilson MJ, Cooper G, MacArthur C, Shennan A; Comparative Obstetric Mobile Epidural Trial (COMET) Study Group UK. Randomized controlled trial comparing traditional with two mobile epidural techniques: anesthetic and analgesic efficacy. Anesthesiology 2002;97: Angle P, Landy CK, Charles C, Yee J, Watson J, Kung R, Kronberg J, Halpern S, Lam D, Lie LM, Streiner D. Phase 1 development of an index to measure the quality of neuraxial labour analgesia: exploring the perspectives of childbearing women. Can J Anaesth 2010;57: Hodnett ED. Pain and women s satisfaction with the experience of childbirth: a systematic review. Am J Obstet Gynecol 2002;186:S Dickinson JE, Paech MJ, McDonald SJ, Evans SF. Maternal satisfaction with childbirth and intrapartum analgesia in nulliparous labour. Aust N Z J Obstet Gynaecol 2003;43: Brokelman RB, Haverkamp D, van Loon C, Hol A, van Kampen A, Veth R. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty. Eur Orthop Traumatol 2012;3: McCrea BH, Wright ME. Satisfaction in childbirth and perceptions of personal control in pain relief during labour. J Adv Nurs 1999;29: Wong CA, McCarthy RJ, Hewlett B. The effect of manipulation of the programmed intermittent bolus time interval and injection volume on total drug use for labor epidural analgesia: a randomized controlled trial. Anesth Analg 2011;112: ANESTHESIA & ANALGESIA

Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions?

Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions? Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions? Dr Mark Esler Queen Charlotte s and Chelsea Hospital Imperial College Healthcare NHS Trust 2 nd October 2013 2 kangaroos and

More information

NEW MODES OF OBSTETRIC ANALGESIA: DOES PIEB MODE BRING A REAL BENEFIT?

NEW MODES OF OBSTETRIC ANALGESIA: DOES PIEB MODE BRING A REAL BENEFIT? NEW MODES OF OBSTETRIC ANALGESIA: DOES PIEB MODE BRING A REAL BENEFIT? Hawa KEITA-MEYER SERVICE D ANESTHÉSIE. HÔPITAL LOUIS MOURIER, COLOMBES. LABOR PAIN Melzack R. Pain 1984; 19(4): 321-337 LABOR STAGES

More information

Combined spinalepidural. epidural analgesia in labour (review) By Neda Taghizadeh

Combined spinalepidural. epidural analgesia in labour (review) By Neda Taghizadeh Combined spinalepidural versus epidural analgesia in labour (review) By Neda Taghizadeh Cochrane review Cochrane collaboration was founded in 1993 and is named after Archie Cochrane (1909-1988), British

More information

Mitra et al. Sri Lankan Journal of Anaesthesiology: 23(2):61-65(2015) DOI: /slja.v23i2.8068

Mitra et al. Sri Lankan Journal of Anaesthesiology: 23(2):61-65(2015) DOI: /slja.v23i2.8068 DOI: 10.4038/slja.v23i2.8068 Evaluation of analgesic efficacy of the combination of fentanyl with low dose bupivacaine vs ropivacaine using patient controlled epidural analgesia for control of labour pain-

More information

Impact of Drug Delivery Systems on Neuraxial Labor Analgesia

Impact of Drug Delivery Systems on Neuraxial Labor Analgesia Curr Anesthesiol Rep (2013) 3:275 281 DOI 10.1007/s40140-013-0030-9 OBSTETRICAL ANESTHESIA (LR LEFFERT, SECTION EDITOR) Impact of Drug Delivery Systems on Neuraxial Labor Analgesia Srividhya Jayant Iyer

More information

T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 )

T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 ) (Acta Anaesth. Belg., 2006, 57, 45-49) Ropivacaine versus Bupivacaine 0.125% with Fentanyl 1µg/ml for Epidural Labour Analgesia : Is Daily Practice More Important Than Pharmaceutical Choice? T. GIRARD

More information

Original article Pravara Med Rev 2010; 2(3)

Original article Pravara Med Rev 2010; 2(3) Original article Pravara Med Rev 2010; 2(3) A randomized clinical trial to compare continuous epidural infusion technique with that of intermittent boluses for maintenance of epidural labour analgesia

More information

Epidural Analgesia: The Best Mix

Epidural Analgesia: The Best Mix Epidural Analgesia: The Best Mix Clinical Associate Professor Nolan McDonnell FANZCA MClinRes Department of Anaesthesia and Pain Medicine King Edward Memorial Hospital for Women Subiaco, Western Australia

More information

The right drug and dose for neuraxial labour analgesia

The right drug and dose for neuraxial labour analgesia (Acta Anaesth. Belg., 2006, 57, 395-399) The right drug and dose for neuraxial labour analgesia P. Y. DEWANDRE INTRODUCTION Neuraxial analgesia has been demonstrated for many years to be the only safe

More information

Y. Lim, 1 A. T. Sia 2 and C. E. Ocampo 3

Y. Lim, 1 A. T. Sia 2 and C. E. Ocampo 3 Anaesthesia, 2006, 61, pages 339 344 doi:10.1111/j.1365-2044.2006.04535.x Comparison of computer integrated patient controlled epidural analgesia vs. conventional patient controlled epidural analgesia

More information

Patient-controlled epidural analgesia for labor

Patient-controlled epidural analgesia for labor Obstetric Anesthesiology Section Editor: Cynthia A. Wong Focused Review Patient-Controlled Epidural Analgesia for Labor Stephen H. Halpern, MD, MSc, FRCPC* Brendan Carvalho, MBBCh, FRCA Patient-controlled

More information

CSE for labour analgesia. Roshan Fernando: University College Hospital, London

CSE for labour analgesia. Roshan Fernando: University College Hospital, London CSE for labour analgesia Roshan Fernando: University College Hospital, London Lecture outline CSE labour analgesia: indications / technique advantages / disadvantages ambulation recent developments Techniques

More information

Labor Epidural: Local Anesthetics and Beyond

Labor Epidural: Local Anesthetics and Beyond Goals: Labor Epidural: Local Anesthetics and Beyond Pedram Aleshi MD The Changing Practice of Anesthesia September 2012 Review Concept of MLAC Local anesthetic efficacy Local anesthetic sparing effects:

More information

Efficacy of postoperative epidural analgesia Block B M, Liu S S, Rowlingson A J, Cowan A R, Cowan J A, Wu C L

Efficacy of postoperative epidural analgesia Block B M, Liu S S, Rowlingson A J, Cowan A R, Cowan J A, Wu C L Efficacy of postoperative epidural analgesia Block B M, Liu S S, Rowlingson A J, Cowan A R, Cowan J A, Wu C L CRD summary This review evaluated the efficacy of post-operative epidural analgesia. The authors

More information

Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany

Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany Kenneth E Nelson, M.D. Associate Professor Wake Forest University, North Carolina, USA Initiating

More information

NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labour analgesia

NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labour analgesia NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labour analgesia Programmed Intermittent Bolus (PIB) An innovative technique

More information

Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C.

Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C. CSE s for Labor Analgesia PRO! Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C. Tsen, MD Director of

More information

NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labor analgesia

NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labor analgesia NEW! CADD -Solis Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for labor analgesia To provide enough pain relief for childbirth labor and delivery

More information

Title: Epidural Analgesia for Pain Management in Labour. Date: May 03, 2007

Title: Epidural Analgesia for Pain Management in Labour. Date: May 03, 2007 Title: Epidural Analgesia for Pain Management in Labour Date: May 03, 2007 Context and policy issues: Balancing pain control with unwanted maternal and neonatal effects remains a hotly debated topic for

More information

THE earliest reports of neuraxial analgesia for labor

THE earliest reports of neuraxial analgesia for labor Effect of Epidural Infusion Bolus Delivery Rate on the Duration of Labor Analgesia A Randomized Clinical Trial Elizabeth M. S. Lange, M.D., Cynthia A. Wong, M.D., Paul C. Fitzgerald, R.N., M.S., Wilmer

More information

Analgesia after c delivery - wound infusions, tap blocks and intrathecal opioids; what more can we offer our patients?

Analgesia after c delivery - wound infusions, tap blocks and intrathecal opioids; what more can we offer our patients? Analgesia after c delivery - wound infusions, tap blocks and intrathecal opioids; what more can we offer our patients? Ashraf S Habib, MBBCh, MSc, MHSc, FRCA Associate Professor of Anesthesiology Interim

More information

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia British Journal of Anaesthesia 98 (2): 241 5 (2007) doi:10.1093/bja/ael346 Advance Access publication January 8, 2007 OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

More information

NEW! CADD -Solis Ambulatory Pain Management System with Programmed Intermittent Bolus (PIB)

NEW! CADD -Solis Ambulatory Pain Management System with Programmed Intermittent Bolus (PIB) NEW! CADD -Solis Ambulatory Pain Management System with Programmed Intermittent Bolus (PIB) Your solution to better pain management for post-operative pain Programmed Intermittent Bolus (PIB) An innovative

More information

David Gambling, MB, BS,* Jonathan Berkowitz, PhD, Thomas R. Farrell, MD, Alex Pue, MD,* and Dennis Shay, MD*

David Gambling, MB, BS,* Jonathan Berkowitz, PhD, Thomas R. Farrell, MD, Alex Pue, MD,* and Dennis Shay, MD* Society for Obstetric Anesthesia and Perinatology Section Editor: Cynthia A. Wong CME A Randomized Controlled Comparison of Epidural Analgesia and Combined Spinal-Epidural Analgesia in a Private Practice

More information

Although epidural bupivacaine is highly effective

Although epidural bupivacaine is highly effective Original Article 286 Comparison between 0.08% Ropivacaine and 0.06% Levobupivacaine for Epidural Analgesia during Nulliparous Labor: A Retrospective Study in A Single Center Hui-Ling Lee, MD; Liang-Ming

More information

PAIN AND REGIONAL ANESTHESIA

PAIN AND REGIONAL ANESTHESIA PAIN AND REGIONAL ANESTHESIA Anesthesiology 2007; 106:149 56 Copyright 2006, the American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Determination of the Full Dose Response

More information

LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR

LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR Henry Liu * 1,2, Shanglong Yao **1, Frank Rosinia *2 Abstract There is no

More information

Int J Clin Exp Med 2018;11(8): /ISSN: /IJCEM

Int J Clin Exp Med 2018;11(8): /ISSN: /IJCEM Int J Clin Exp Med 2018;11(8):8003-8010 www.ijcem.com /ISSN:1940-5901/IJCEM0078281 Original Article Efficacy and side effects comparison of bupivacaine and ropivacaine with fentanyl for labor analgesia

More information

Epidural Analgesia with Amide Local Anesthetics, Bupivacaine, and Ropivacaine in Combination with Fentanyl for Labor Pain Relief: A Meta-Analysis

Epidural Analgesia with Amide Local Anesthetics, Bupivacaine, and Ropivacaine in Combination with Fentanyl for Labor Pain Relief: A Meta-Analysis e-issn 1643-3750 Med Sci Monit, 15; 21: 921-928 DOI: 10.12659/MSM.892276 Received: 14.08.19 Accepted: 14.10.24 Published: 15.03.29 Epidural Analgesia with Amide Local Anesthetics, Bupivacaine, and Ropivacaine

More information

REVIEW ARTICLE. Molecular Orthopaedics, Beijing Institute of Traumatology and Orthopaedics, Beijing, China

REVIEW ARTICLE. Molecular Orthopaedics, Beijing Institute of Traumatology and Orthopaedics, Beijing, China 294 2016 THE AUTHORS. PUBLISHED BY JOHN WILEY &SONS AUSTRALIA, LTD AND CHINESE ORTHOPAEDIC ASSOCIATION REVIEW ARTICLE Analgesic Efficacy of Adductor Canal Block in Total Knee Arthroplasty: A Meta-analysis

More information

Nitrous Oxide During Labor: Maternal Satisfaction Does Not Depend Exclusively on Analgesic Effectiveness

Nitrous Oxide During Labor: Maternal Satisfaction Does Not Depend Exclusively on Analgesic Effectiveness Nitrous Oxide During Labor: Maternal Satisfaction Does Not Depend Exclusively on Analgesic Effectiveness Michael G. Richardson, MD,* Brandon M. Lopez, MD,* Curtis L. Baysinger, MD,* Matthew S. Shotwell,

More information

CAESAREAN SECTION Brian Fredman

CAESAREAN SECTION Brian Fredman CHAPTER 3 GYNAECOLOGICAL SURGERY CAESAREAN SECTION Brian Fredman Review of evidence: surgical site infusion Of the seven studies on surgical site local anaesthetic infusion after Caesarean section performed

More information

Combined spinal-epidural versus epidural analgesia in labour (Review)

Combined spinal-epidural versus epidural analgesia in labour (Review) Combined spinal- versus analgesia in labour (Review) Simmons SW, Cyna AM, Dennis AT, Hughes D This is a reprint of a Cochrane review, prepared and maintained by The Cochrane Collaboration and published

More information

Comparison between Patient-Controlled Epidural Analgesia and Continuous Epidural Infusion for Pain Relief after Gynaecological Surgery

Comparison between Patient-Controlled Epidural Analgesia and Continuous Epidural Infusion for Pain Relief after Gynaecological Surgery Original Research Article Comparison between Patient-Controlled Epidural Analgesia and Continuous Epidural Infusion for Pain Relief after Gynaecological Surgery Suhaila N 1, Nurlia Y 2 ( ), Azmil Farid

More information

COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR

COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR Br.J. Anaesth. (1977), 49, 75 COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR D. G. LITTLEWOOD, D. B. SCOTT, J. WILSON AND B. G. COVINO SUMMARY Various

More information

OB Div News March 2009

OB Div News March 2009 OB Div News March 2009 Several articles in this month s review have come from Canadian institutions. In spite of my pride in being Canadian, which was enhanced during the Olympics, this is purely coincidental.

More information

Almost two decades have passed since French and American trials

Almost two decades have passed since French and American trials PERIODICUM BIOLOGORUM UDC 57:61 VOL. 111, No 2, 171 185, 2009 CODEN PDBIAD ISSN 0031-5362 Review Modern neuraxial labor analgesia: options for initiation, maintenance and drug selection MARC VAN DE VELDE

More information

Combined Spinal epidural with Levobupivacaine or Ropivacaine with Fentanyl for Labor Analgesia: A Comparative Study

Combined Spinal epidural with Levobupivacaine or Ropivacaine with Fentanyl for Labor Analgesia: A Comparative Study ORIGINAL ARTICLE Combined Spinal epidural with Levobupivacaine or Ropivacaine 10.5005/jp-journals-10050-10080 with Fentanyl for Labor Analgesia Combined Spinal epidural with Levobupivacaine or Ropivacaine

More information

Show Me the Evidence: Epidurals, PVBs, TAP Blocks Christopher L. Wu, MD Professor of Anesthesiology The Johns Hopkins Hospital

Show Me the Evidence: Epidurals, PVBs, TAP Blocks Christopher L. Wu, MD Professor of Anesthesiology The Johns Hopkins Hospital Show Me the Evidence: Epidurals, PVBs, TAP Blocks Christopher L. Wu, MD Professor of Anesthesiology The Johns Hopkins Hospital Overview Review overall (ERAS and non-eras) data for EA, PVB, TAP Examine

More information

NEURAXIAL LABOR ANALGESIA. Thierry Girard

NEURAXIAL LABOR ANALGESIA. Thierry Girard NEURAXIAL LABOR ANALGESIA Thierry Girard 7 April 1853 Prince Leopold, Duke of Albany Proc (Bayl Univ Med Cent) 2006;19:24 28 07/2013 Hypnosis for pain management during labour and childbirth (Review) Madden

More information

Faculty Development Talk

Faculty Development Talk Faculty Development Talk Updates in Obstetric Anaesthesia Leong Wan Ling Consultant, Women s Anaesthesia, KK Women s & Children s Hospital 13 th September 2017 Topics Labour ward Neuraxial anaesthesia

More information

Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors

Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors Cristian Arzola MD MSc Department of Anesthesia and Pain Management Mount Sinai Hospital and University of

More information

Systematic reviews and meta-analyses of observational studies (MOOSE): Checklist.

Systematic reviews and meta-analyses of observational studies (MOOSE): Checklist. Systematic reviews and meta-analyses of observational studies (MOOSE): Checklist. MOOSE Checklist Infliximab reduces hospitalizations and surgery interventions in patients with inflammatory bowel disease:

More information

DATE: 17 January 2011 CONTEXT AND POLICY ISSUES

DATE: 17 January 2011 CONTEXT AND POLICY ISSUES TITLE: Use of Fentanyl and Continuous Electronic Fetal Monitoring in Labour and Delivery: A Review of Clinical Effectiveness, Safety, and Clinical Practice Guidelines DATE: 17 January 2011 CONTEXT AND

More information

The QUOROM Statement: revised recommendations for improving the quality of reports of systematic reviews

The QUOROM Statement: revised recommendations for improving the quality of reports of systematic reviews The QUOROM Statement: revised recommendations for improving the quality of reports of systematic reviews David Moher 1, Alessandro Liberati 2, Douglas G Altman 3, Jennifer Tetzlaff 1 for the QUOROM Group

More information

section: levobupivacaine 0.15% versus ropivacaine 0.15% alone or combined with fentanyl 2 µg/ml: a comparative study

section: levobupivacaine 0.15% versus ropivacaine 0.15% alone or combined with fentanyl 2 µg/ml: a comparative study Clinical research Patient-controlled epidural analgesia after Caesarean section: levobupivacaine 0.15% versus ropivacaine 0.15% alone or combined with fentanyl 2 µg/ml: a comparative study Paraskevi Matsota,

More information

Maternal & fetal outcomes after regional labour analgesia Ultra low dose epidurals to BUMPES. Dr Bernard J Norman November 2012

Maternal & fetal outcomes after regional labour analgesia Ultra low dose epidurals to BUMPES. Dr Bernard J Norman November 2012 Maternal & fetal outcomes after regional labour analgesia Ultra low dose epidurals to BUMPES Dr Bernard J Norman November 2012 Mother Fetus Mother The Birth of Queen Victoria s Eighth Child, Prince Leopold,

More information

CHA Gumi Medical Center, CHA University, Gumi, Korea

CHA Gumi Medical Center, CHA University, Gumi, Korea Anesth Pain Med 2014; 9: 65-69 Clinical Research Comparison of 0.5% ropivacaine with fentanyl and 0.75% ropivacaine used in extension of a preexisting labor epidural for emergency cesarean section: retrospective

More information

Although intrathecal (IT) sufentanil provides effective

Although intrathecal (IT) sufentanil provides effective Combination of Intrathecal Sufentanil 10 g Plus Bupivacaine 2.5 mg for Labor Analgesia: Is Half the Dose Enough? Alex T. H. Sia, MMed, Jin L. Chong, MMed, and Jen W. Chiu, MMed Department of Anesthesia,

More information

What s New in Post-Cesarean Analgesia?

What s New in Post-Cesarean Analgesia? Anesthesia & Obstetrics What s New in Post-Cesarean Analgesia? October 23rd, 2013 2013 UCSF What Does The Evidence Tell Us? Mark Rollins, MD, PhD UC SF Post-Delivery Pain (Mean pain scores for first 24

More information

Assistant Professor, Anaesthesia Department, Govt. General Hospital / Guntur Medical College, Guntur, Andhra Pradesh, India.

Assistant Professor, Anaesthesia Department, Govt. General Hospital / Guntur Medical College, Guntur, Andhra Pradesh, India. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 15, Issue 8 Ver. I (August. 2016), PP 87-91 www.iosrjournals.org A Comparative Study of 0.25% Ropivacaine

More information

Is There an Ideal Regimen for CPNB?

Is There an Ideal Regimen for CPNB? Is There an Ideal Regimen for CPNB? Dr Eric Albrecht, MD, DESA Department of Anesthesiology, CHUV 2nd SARA Annual Symposium June 2013 Manuel pratique d ALR échoguidé, Elsevier Masson, Paris, 2013 Albrecht

More information

Labor pain relief using bupivacaine and sufentanil: Patient controlled epidural analgesia versus intermittent injections

Labor pain relief using bupivacaine and sufentanil: Patient controlled epidural analgesia versus intermittent injections European Journal of Obstetrics & Gynecology and Reproductive Biology 59 Supp!. (1995) S47-S54 Labor pain relief using bupivacaine and sufentanil: Patient controlled epidural analgesia versus intermittent

More information

Research questions: What is the clinical and cost-effectiveness of PCA to manage pain in a hospital setting?

Research questions: What is the clinical and cost-effectiveness of PCA to manage pain in a hospital setting? Title: Patient Controlled Analgesia for Pain Management Date: May 9, 2007 Context and policy issues: Pain following surgery is often treated inadequately, with about 75% of patients experiencing moderate

More information

Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent

Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent British Journal of Anaesthesia 1997; 78: 493 497 CLINICAL INVESTIGATIONS Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent G. LYONS, M. COLUMB, L. HAWTHORNE

More information

E. Sitsen (*), F. van Poorten (**), G. Jansen (***), R. Kuijpers (**), A. Dahan (*) and

E. Sitsen (*), F. van Poorten (**), G. Jansen (***), R. Kuijpers (**), A. Dahan (*) and (Acta Anaesth. Belg., 2012, 63, 169-175) A comparison of the efficacy of levobupivacaine 0,125%, ropivacaine 0,125% and ropivacaine 0,2%, all combined with sufentanil 0.5 µg/ml, in patient-controlled epidural

More information

Remifentanil PCA In Labor

Remifentanil PCA In Labor Remifentanil PCA In { Jennifer Lucero, MD Clinical Instructor UCSF Department of Anesthesia Remifentanil PCA in Discuss the Pharmokinectics of Remifentanil Review literature on the use of Remifentanil

More information

Remifentanil in labour analgesia where are we in 2017 an update.

Remifentanil in labour analgesia where are we in 2017 an update. Remifentanil in labour analgesia where are we in 2017 an update. Vegard Dahl, Head of Dept of Anaesthesia and Intensive Care, Professor, Akershus University Hospital, Norway Disclosures None Agenda Pharmacology

More information

Options for analgesia when a regional technique is not possible

Options for analgesia when a regional technique is not possible Options for analgesia when a regional technique is not possible Damien Hughes Ulster Hospital Belfast Damien.Hughes@setrust.hscni.net History Progress. Plus ça change.. Basic choices.. Pharmacological

More information

Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial

Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial Surjeet Singh, 1 V.P. Singh, 2 Manish Jain, 3 Kumkum Gupta, 3 Bhavna Rastogi,

More information

T A B L E O F C O N T E N T S

T A B L E O F C O N T E N T S Short-term psychodynamic psychotherapies for anxiety, depression and somatoform disorders (Unknown) Abbass AA, Hancock JT, Henderson J, Kisely S This is a reprint of a Cochrane unknown, prepared and maintained

More information

ORIGINAL ARTICLE. Srivastava Meghana 1, Arora Garima 2, Santpur Madhavi 3, Kanwal Preet 4, Bansal Karishma 4 ABSTRACT

ORIGINAL ARTICLE. Srivastava Meghana 1, Arora Garima 2, Santpur Madhavi 3, Kanwal Preet 4, Bansal Karishma 4 ABSTRACT ORIGINAL ARTICLE ANAESTHESIA, PAIN & INTENSIVE CARE www.apicareonline.com Efficacy of bupivacaine and ropivacaine for postoperative analgesia in continuous epidural infusion in lower limb surgeries under

More information

Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia

Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia ISPUB.COM The Internet Journal of Anesthesiology Volume 33 Number 1 Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia S Gautam, S Singh, R Verma, S Kumar,

More information

Cochrane Pregnancy and Childbirth Group Methodological Guidelines

Cochrane Pregnancy and Childbirth Group Methodological Guidelines Cochrane Pregnancy and Childbirth Group Methodological Guidelines [Prepared by Simon Gates: July 2009, updated July 2012] These guidelines are intended to aid quality and consistency across the reviews

More information

How to reduce failure rate of regional anaesthesia for caesarean section? Mike Kinsella St Michael s Hospital, Bristol 4 th November 2010

How to reduce failure rate of regional anaesthesia for caesarean section? Mike Kinsella St Michael s Hospital, Bristol 4 th November 2010 How to reduce failure rate of regional anaesthesia for caesarean section? Mike Kinsella St Michael s Hospital, Bristol 4 th November 2010 Define failure GA conversion; RCoA standards Cat 4

More information

Insertion of an intrathecal catheter following accidental dural puncture: a meta-analysis

Insertion of an intrathecal catheter following accidental dural puncture: a meta-analysis International Journal of Obstetric Anesthesia (2013) 22, 26 30 0959-289X/$ - see front matter c 2012 Elsevier Ltd. All rights reserved. http://dx.doi.org/10.1016/j.ijoa.2012.10.004 REVIEW ARTICLE Insertion

More information

Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor

Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor Epidural Neostigmine versus Fentanyl to Decrease Bupivacaine Use in Patient-controlled Epidural Analgesia during Labor A Randomized, Double-blind, Controlled Study Jessica L. Booth, M.D., Vernon H. Ross,

More information

Local anesthetic infusion pump for pain management following total knee arthroplasty: a meta-analysis

Local anesthetic infusion pump for pain management following total knee arthroplasty: a meta-analysis Zhang et al. BMC Musculoskeletal Disorders (2017) 18:32 DOI 10.1186/s12891-016-1382-3 RESEARCH ARTICLE Open Access Local anesthetic infusion pump for pain management following total knee arthroplasty:

More information

Systematic review: The effectiveness and safety of diclofenac for the. pain management after cesarean

Systematic review: The effectiveness and safety of diclofenac for the. pain management after cesarean Systematic review: The effectiveness and safety of diclofenac for the pain management after cesarean ABSTRACT This is the protocol of systematic review and there is no abstract. The objective is to evaluate

More information

Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section

Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section The Journal of International Medical Research 2012; 40: 1099 1107 Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section SW FENG,

More information

Patient-controlled epidural Levobupicvacaine with or without Fentanyl for post-cesarean section pain relief

Patient-controlled epidural Levobupicvacaine with or without Fentanyl for post-cesarean section pain relief Washington University School of Medicine Digital Commons@Becker Open Access Publications 2014 Patient-controlled epidural Levobupicvacaine with or without Fentanyl for post-cesarean section pain relief

More information

REGIONAL/LOCAL ANESTHESIA and OBESITY

REGIONAL/LOCAL ANESTHESIA and OBESITY REGIONAL/LOCAL ANESTHESIA and OBESITY Jay B. Brodsky, MD Stanford University School of Medicine Jbrodsky@stanford.edu Potential Advantages Regional compared to General Anesthesia Minimal intra-operative

More information

Post Caesarean Analgesia An Update. Kim Ekelund MD, PhD, associate professor Rigshospitalet Copenhagen, Denmark

Post Caesarean Analgesia An Update. Kim Ekelund MD, PhD, associate professor Rigshospitalet Copenhagen, Denmark Post Caesarean Analgesia An Update Kim Ekelund MD, PhD, associate professor Rigshospitalet Copenhagen, Denmark Post caesarean analgesia No Conflicts of Interests Neuraxial opioids Multimodal therapy Plan

More information

Problem solving therapy

Problem solving therapy Introduction People with severe mental illnesses such as schizophrenia may show impairments in problem-solving ability. Remediation interventions such as problem solving skills training can help people

More information

CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour

CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour Dr Jason Reidy Nuffield Department of Anaesthetics Oxford University Hospitals CSE analgesia does not represent the gold standard

More information

Continuous spinal analgesia via a spinal catheter

Continuous spinal analgesia via a spinal catheter Continuous Spinal Analgesia for Labor and Delivery: An Observational Study with a 23-Gauge Spinal Catheter Weike Tao, MD,* Erica N. Grant, MD, MSc,* Margaret G. Craig, MD,* Donald D. McIntire, PhD, and

More information

Epidural analgesia and backache: a randomized controlled comparison with intramuscular meperidine for analgesia during labour

Epidural analgesia and backache: a randomized controlled comparison with intramuscular meperidine for analgesia during labour British Journal of Anaesthesia 89 (3): 466-72 (2002) analgesia and backache: a randomized controlled comparison with intramuscular meperidine for analgesia during labour B. A. Loughnan *, F. Carli 2, M.

More information

Chronic pain after childbirth. Petter Kainu Split

Chronic pain after childbirth. Petter Kainu Split Chronic pain after childbirth Petter Kainu Split 9.5.13 Backround: 128 milj. births per year world wide 18.5 milj. caesarean sections (WHO 2008) 234 milj. surgical operations per year (WHO 2004) Chronic

More information

In a previous study from our institution, we found

In a previous study from our institution, we found A Randomized, Double-Blind, Placebo-Controlled Trial of Morphine Analgesia After Vaginal Delivery Alison Macarthur, MD, MSc* Charles Imarengiaye, MD Luminita Tureanu, MD Kristi Downey, MSc* BACKGROUND:

More information

Postoperative epidural analgesia using local anesthetic

Postoperative epidural analgesia using local anesthetic REGIONAL ANESTHESIA SECTION EDITOR DENISE J. WEDEL A Comparison of 0.1% and 0.2% Ropivacaine and Bupivacaine Combined with Morphine for Postoperative Patient-Controlled Epidural Analgesia After Major Abdominal

More information

Role and safety of epidural analgesia

Role and safety of epidural analgesia Anaesthesia for Liver Resection Surgery The Association of Anaesthetists Seminars 21 Portland Place, London Thursday 15 th December 2005 Role and safety of epidural analgesia Lennart Christiansson MD,

More information

PAIN AND REGIONAL ANESTHESIA. Materials and Methods

PAIN AND REGIONAL ANESTHESIA. Materials and Methods PAIN AND REGIONAL ANESTHESIA Anesthesiology 2004; 101:439 44 2004 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Epidural Neostigmine Combined with Sufentanil Provides

More information

Results. NeuRA Worldwide incidence April 2016

Results. NeuRA Worldwide incidence April 2016 Introduction The incidence of schizophrenia refers to how many new cases there are per population in a specified time period. It is different from prevalence, which refers to how many existing cases there

More information

American Journal of Internal Medicine

American Journal of Internal Medicine American Journal of Internal Medicine 2016; 4(3): 49-59 http://www.sciencepublishinggroup.com/j/ajim doi: 10.11648/j.ajim.20160403.12 ISSN: 2330-4316 (Print); ISSN: 2330-4324 (Online) The Effect of Dose-Reduced

More information

Closed-loop Double-pump Automated System Manual Boluses

Closed-loop Double-pump Automated System Manual Boluses Closed-loop Double-pump Automated System versus Manual Boluses to treat Hypotension during Spinal Anaesthesia for Caesarean Section: randomised controlled trial Dr. Ban Leong SNG MBBS, MMED, FANZCA, FFPMANZCA,

More information

Medicine. Chao Han (MD) a, Xiao-dan Li (MD) b, Hong-qiang Jiang (MD) a, Jian-xiong Ma (PhD) a, Xin-long Ma (MD) a, Systematic Review and Meta-Analysis

Medicine. Chao Han (MD) a, Xiao-dan Li (MD) b, Hong-qiang Jiang (MD) a, Jian-xiong Ma (PhD) a, Xin-long Ma (MD) a, Systematic Review and Meta-Analysis Systematic Review and Meta-Analysis Medicine The use of gabapentin in the management of postoperative pain after total knee arthroplasty A PRISMA-compliant meta-analysis of randomized controlled trials

More information

WITH ISOBARIC BUPIVACAINE (5 MG/ML)

WITH ISOBARIC BUPIVACAINE (5 MG/ML) , 49, 2013, 3 63 (5 MG/ML) (5 MG/ML).,.,.,..,..,, SPINAL ANESTHESIA: COMPARISON OF ISOBARIC ROPIVACAINE (5 MG/ML) WITH ISOBARIC BUPIVACAINE (5 MG/ML) D. Tzoneva, Vl. Miladinov, Al. Todorov, M. P. Atanasova,

More information

PROSPERO International prospective register of systematic reviews

PROSPERO International prospective register of systematic reviews PROSPERO International prospective register of systematic reviews Closed reduction methods for acute anterior shoulder dislocation [Cochrane Protocol] Kanthan Theivendran, Raj Thakrar, Subodh Deshmukh,

More information

Merja Kokki MD, PhD Department of Anaesthesiology and Intensive Care, Kuopio University Hospital, School of Medicine, University of Eastern Finland

Merja Kokki MD, PhD Department of Anaesthesiology and Intensive Care, Kuopio University Hospital, School of Medicine, University of Eastern Finland Long-acting opioids in obstetric analgesia and the newborn Merja Kokki MD, PhD Department of Anaesthesiology and Intensive Care, Kuopio University Hospital, School of Medicine, University of Eastern Finland

More information

Morphine for post-caesarean section analgesia: intrathecal, epidural or intravenous?

Morphine for post-caesarean section analgesia: intrathecal, epidural or intravenous? O r i g i n a l A r t i c l e Singapore Med J 2005; 46(8) : 392 Morphine for post-caesarean section analgesia: intrathecal, epidural or intravenous? Y Lim, S Jha, A T Sia, N Rawal ABSTRACT Introduction:

More information

REVISTA BRASILEIRA DE ANESTESIOLOGIA

REVISTA BRASILEIRA DE ANESTESIOLOGIA Rev Bras Anestesiol. 2013;63(5):433-442 REVISTA BRASILEIRA DE ANESTESIOLOGIA Official Publication of the Brazilian Society of Anesthesiology www.sba.com.br MISCELLANEOUS Comparison between Continuous Thoracic

More information

Comparison of 0.125% ropivacaine-dexmedetomidine versus 0.125% levobupivacaine-dexmedetomidine for epidural labour analgesia

Comparison of 0.125% ropivacaine-dexmedetomidine versus 0.125% levobupivacaine-dexmedetomidine for epidural labour analgesia Comparison of 0.125% ropivacaine-dexmedetomidine versus 0.125% levobupivacaine-dexmedetomidine for epidural labour analgesia ABSTRACT Background: Levobupivacine and Ropivacaine are two new local anaesthetics

More information

Impact of asystematic review on subsequent clinical research

Impact of asystematic review on subsequent clinical research Impact of asystematic review on subsequent clinical research The case of the prevention of propofol injection pain Céline Habre 1,Martin R Tramèr 1,DanielM Pöpping 2, Nadia Elia 1,3 1 Division of Anaesthesiology,

More information

Results. NeuRA Treatments for internalised stigma December 2017

Results. NeuRA Treatments for internalised stigma December 2017 Introduction Internalised stigma occurs within an individual, such that a person s attitude may reinforce a negative self-perception of mental disorders, resulting in reduced sense of selfworth, anticipation

More information

Results. NeuRA Hypnosis June 2016

Results. NeuRA Hypnosis June 2016 Introduction may be experienced as an altered state of consciousness or as a state of relaxation. There is no agreed framework for administering hypnosis, but the procedure often involves induction (such

More information

A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center

A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center Research Article TheScientificWorldJOURNAL (2009) 9, 715 722 ISSN 1537-744X; DOI 10.1100/tsw.2009.94 A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics

More information

Richard Smiley, MD, PhD Virginia Apgar MD Professor of Anesthesiology Chief, Obstetric Anesthesia Columbia University Medical Center New York, NY,

Richard Smiley, MD, PhD Virginia Apgar MD Professor of Anesthesiology Chief, Obstetric Anesthesia Columbia University Medical Center New York, NY, Richard Smiley, MD, PhD Virginia Apgar MD Professor of Anesthesiology Chief, Obstetric Anesthesia Columbia University Medical Center New York, NY, USA Disclosures Off label use: Fentanyl, Sufentanil IT

More information

M.E. Bauer, a J.A. Kountanis, a L.C. Tsen, b M.L. Greenfield, a J.M. Mhyre a ORIGINAL ARTICLE. Introduction

M.E. Bauer, a J.A. Kountanis, a L.C. Tsen, b M.L. Greenfield, a J.M. Mhyre a ORIGINAL ARTICLE. Introduction International Journal of Obstetric Anesthesia (2012) 21, 294 309 0959-289X/$ - see front matter c 2012 Elsevier Ltd. All rights reserved. http://dx.doi.org/10.1016/j.ijoa.2012.05.007 ORIGINAL ARTICLE Risk

More information

COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL

COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL COMPLICATIONS AND INTERVENTIONS ASSOCIATED WITH EPIDURAL ANALGESIA FOR POSTOPERATIVE PAIN RELIEF IN A TERTIARY CARE HOSPITAL Faraz Shafiq *, Mohammad Hamid ** and Khalid Samad *** Introduction Epidural

More information

Spinal Anaesthesia for Caesarean Delivery. Pervez Sultan University College London Hospital

Spinal Anaesthesia for Caesarean Delivery. Pervez Sultan University College London Hospital Spinal Anaesthesia for Caesarean Delivery Pervez Sultan University College London Hospital Disclosures How to Deliver an Evidence- Based Spinal Anaesthetic CSE vs. spinal Block height assessment Drugs

More information