1 InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior
2 Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups, which employs a phenyl ring with a hexyl (6- carbon) linker and is densely bonded to our newly developed ES silica gel delivering complementary selectivity to straight alkyl-chain columns, but with industry leading reproducibility, inertness and low back pressure. Physical Properties Silica : ES (Evolved Surface) Silica Gel Particle Size : μm, 5 μm Surface Area : 50 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.85 ml/g Bonded Phase : Phenylhexyl Groups End-capping : Complete Carbon Loading : 9.0 % USP Code : L ph Range :.0 to 0.0 Benefits Different selectivity to C8 phases Strong Retentivity than other Phenyl phases Highly inert packing material results in less tailing of peaks for virtually any type of analytes Deliver extreme sensitivity analysis in LC-MS and LC-MS/MS methods Extreme resistance to low and high ph mobile phases Excellent stability to 00 % aqueous mobile phases Compatible with The European Pharmacopeia (Ph. Eur.) methods Endlessly reproducible from column-to-column and batch-to-batch
3 Different Selectivity to C8 Phases The following selectivity test was used to understand the difference in selectivity between a conventional C8 phase, Phenylhexyl and Phenyl phases. Column Size : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH OH B) H O A/B = 70/0, v/v Flow Rate :.0 ml/min Col. Temp. :40 Detection :UV 54 nm Sample : 4 5, 6 7 InertSustain C8. Uracil. Caffeine. Phenol 4. n-butylbenzene 5. o-terphenyl 6. n-amylbenzene 7. Triphenylene InertSustain Phenylhexyl Bonded Phase: Phenylhexyl Groups (C6-Ph) InertSustain Phenyl Bonded Phase: Phenyl Groups (C0-Ph) Sample o., Uracil cannot be retained in a reversed phase mode when using the mobile phase condition described on the right. Therefore, Uracil was used to determine the t0 position. t0: Void Volume Sample o.,, Caffeine and Phenol are used to confirm the amount of residual silanol on the surface of the silica gel. Caffeine elutes later against Phenol when there is a lot of residual silanol on the surface of the silica gel. Sample o.4, n-butylbenzene and Sample o.6, n-amylbenzene were used to determine the hydrophobic property of the column. n-amylbenzene elutes later against n-butylbenzene when the hydrophobicity of the column is high. Stereoselectivity is indicated by Sample o.5, o-terphenyl and Sample o.7, Triphenylene. o-terphenyl has a twisted tertiary structure and Triphenylene has a planar structure. Triphenylene elutes later against o-terphenyl when the stereoselectivity of the column is high.
4 Comparison of Selectivity Between a C8 and Phenylhexyl Phase Figure compares the selectivity provided by a conventional C8 and Phenylhexyl phase. InertSustain Phenylhexyl show stronger retention of compounds containing nitro groups. Figure compares the separation of analgesic drugs on a conventional C8 and Phenylhexyl phase. Indomethacin was strongly retained on InertSustain Phenylhexyl due to the presence of strong pi-pi interaction resulting in change in elution order with better separation InertSustain C8 Figure. Column Size : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH OH B) H O A/B = 0/70, v/v Flow Rate :.0 ml/min Col. Temp. : 40 Detection : UV 0 nm Sample :.,,5-Trinitrobenzene.,-Dinitrobenzene. itrobenzene O O O O O.,,5-Trinitrobenzene.,-Dinitrobenzene O InertSustain Phenylhexyl. itrobenzene Analysis of Analgesic Drugs InertSustain C8 Figure. Column Size : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH C B) 5 mm KH PO 4 (ph.0, H PO 4 ) A/B = 45/55, v/v Flow Rate :.0 ml/min Col. Temp. :40 Detection :UV 0 nm Sample :. Indomethacin. Ibuprofen O Cl H C O CH OH H C CH H CH O OH InertSustain Phenylhexyl O. Indomethacin. Ibuprofen
5 Strong Retentivity than other Phenyl Phases The retentivity of InertSustain Phenylhexyl is stronger comparing with commercially available Phenyl columns. Sample o.5, n-amylbenzene was used to determine the hydrophobic property of columns , InertSustain Phenylhexyl 6 6 7, Column Size : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH OH B) H O A/B = 70/0, v/v Flow Rate :.0 ml/min Col. Temp. :40 Detection :UV 54 nm Sample :. Uracil. Caffeine. Phenol 4. n-butylbenzene 5. n-amylbenzene 6 6. Triphenylene 7. o-terphenyl XBridge Phenyl Inertsil Ph, , , Luna Phenyl-Hexyl InertSustain Phenyl Zorbax Phenyl-Hexyl Inertsil Ph-
6 Benefits of Highly Inert Packing Material InertSustain Phenylhexyl also maintains the same extreme inertness, wide ph range and provide separations with symmetric peaks. Poorly end-capped columns often show tailing of peaks due to the presence of silanols resulting in longer analysis time. Analysis of Antidepressants 4 Eluent Flow Rate Col. Temp. :40 Detection :UV 54 nm Sample :A) CH C B) 5 mm KH PO 4 (ph 7.0, K HPO 4 ) A/B = 50/50, v/v :.0 ml/min :. Imipramine hydrochloride. Amitriptyline hydrochloride. Clomipramine hydrochloride 4. Mianserin hydrochloride 0 0 InertSustain Phenylhexyl. Imipramine hydrochloride. Amitriptyline hydrochloride 4 H C Cl H 0 0 Luna Phenyl-Hexyl. Clomipramine hydrochloride 4. Mianserin hydrochloride
7 Extreme Sensitivity Analysis in LC-MS and LC-MS/MS Methods The usage of highly inert packing material creates another benefit for LC-MS and LC-MS/MS applications. As shown below, InertSustain Phenylhexyl deliver excellent peak shape and high sensitivity even with strong basic analyte. H CO H Dextromethorphan CH System Column Eluent : GL QTRAP : μm, 50 x. mm I.D. : A) CH C B) 0 mm CH COOH 4 in H O A/B = 0/70 (gradient mixer ), v/v :0 μl/min Flow rate Col. Temp. :40 Detection :SIM (ESI, Positive ) CUR IS TEM GS GS ihe O Injection Vol. Sample : μl :Dextromethorphan (50 ng/ml).0e6.0e6.0e6 Max..e6 cps..0e6 Max..7e6 cps..0e6.0e InertSustain Phenylhexyl Other Brands Phenyl Column
8 Wide ph Compatibility with Long Column Lifetime As shown in the experiment below, InertSustain Phenylhexyl maintained high efficiency for 0 hours. % Initial Purging Column :5 μm, mm I.D. Eluent :A) 50 mm Triethylamine (ph 9.5) B)CH OH A/B = 70/0, v/v Flow Rate :.0 ml/min Col. Temp. :50 Eluent :CH C/H O = 65/5, v/v Flow Rate :.0 ml/min Col. Temp. :40 Detection :UV 54 nm Sample :aphthalene Hours of Purging (h) Excellent Stability to 00 % Aqueous Mobile Phases When analyzing hydrophilic compounds under water rich mobile phase condition, once the pump is stopped, the hydrophobic bonded group pushes the aqueous mobile phase out off the pore in an irreversible fashion, in what has become known as the dewetting phenomenon. As shown in the following test, InertSustain Phenylhexyl demonstrates excellent stability to dewetting guaranteeing highly stable, reliable and reproducible chromatograms. 4 First Injection Dewetting Test Column : 5 μm, 50 x 4.6 mm I.D. Eluent : 00 % H O Flow rate :.0 ml/min Col. Temp. : 40 Detection : UV 54 nm Sample :.Cytosine.Uracil.Guanine 4.Thymine 5.Adenine InertSustain Phenylhexyl Second Injection Variation: % Testing Procedure ) 00 % water is introduced into column over 60 minutes. ) Conduct analysis. ) Stop flow for 5 minutes. 4) 00 % water is introduced again into column over 0 minutes. 5) Stop flow for 5 minutes again. 6) Conduct analysis.
9 Compatible with The European Pharmacopeia (Ph. Eur.) Methods Analysis of Indomethacin H C O O CH OH O Indomethacin Cl Column : μm, 50 x 4.6 mm I.D. Eluent : A) 0 g/l CH COOH in H O B) CH C A/B = 70/0 min - 70/0 9 min - 50/50 min 50/50-0 min - 70/0 9 min - 0/70 6 min - 0/70, v/v Flow Rate :.0 ml/min Col. Temp. : 40 Detection : UV 54 nm Injection Vol. : μl Criteria : Indomethacin to be eluted approx. 8 min 0 0 InertSustain Phenylhexyl Access to the latest pharmaceutical, life science, environmental and food applications at
10 Comparison of Performance By conducting the tests below, we can evaluate the degree of inertness of the column. To strictly evaluate all columns, the below mentioned samples were used, which are all known as strong adsorptive compounds. Strong Basic Compound Test Dextromethorphan and Berberine Chloride are strong basic compounds. Severe tailing can be confirmed when the packing material contains residual silanol groups. H CO Column : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH C B) 5 mm K HPO 4 (ph 7.0, KH PO 4 ) A/B = 40/60,v/v Flow Rate :.0 ml/min Col. Temp. : 40 Detection : UV 0 nm Injection Vol : μl Sample : : Dextromethorphan H CH :Dextromethorphan Strong Acidic Compound Test Brilliant Blue FCF has three sulfonic groups in its chemical structure, severe tailing will occur when the surface of the packing material is slightly basic. - O S SO - SO - Column : 5 μm, 50 x 4.6 mm I.D. Eluent : A) CH C B) 0. % H PO 4 A/B = 5/75,v/v Flow Rate :.0 ml/min Col. Temp. : 40 Detection : UV 54 nm Injection Vol : 5 μl Sample : :Brilliant Blue FCF :Phenol :Salicylic acid + :Brilliant Blue FCF
11 Comparison of Performance Strong Basic Compound Test Strong Acidic Compound Test InertSustain Phenylhexyl : Dextromethorphan : Brilliant Blue FCF : Phenol : Salicylic acid Luna Phenyl-Hexyl. o peak XBridge Phenyl. o peak Zorbax Phenyl-Hexyl. o peak
12 Analytical Columns InertSustain Phenylhexyl HP µm.x0mm InertSustain Phenylhexyl HP µm.x50mm InertSustain Phenylhexyl HP µm.x75mm InertSustain Phenylhexyl HP µm.x00mm InertSustain Phenylhexyl HP µm.x50mm InertSustain Phenylhexyl HP µm.x50mm InertSustain Phenylhexyl HP µm.0x0mm InertSustain Phenylhexyl HP µm.0x50mm InertSustain Phenylhexyl HP µm.0x75mm InertSustain Phenylhexyl HP µm.0x00mm InertSustain Phenylhexyl HP µm.0x50mm InertSustain Phenylhexyl HP µm.0x50mm InertSustain Phenylhexyl HP µm 4.6x0mm InertSustain Phenylhexyl HP µm 4.6x50mm InertSustain Phenylhexyl HP µm 4.6x75mm InertSustain Phenylhexyl HP µm 4.6x00mm InertSustain Phenylhexyl HP µm 4.6x50mm InertSustain Phenylhexyl HP µm 4.6x50mm 50 * End-fittings are /6 Waters-compatible.
13 Analytical Columns InertSustain Phenylhexyl µm.0x0mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm.0x75mm InertSustain Phenylhexyl µm.0x00mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm.5x0mm InertSustain Phenylhexyl µm.5x50mm InertSustain Phenylhexyl µm.5x75mm InertSustain Phenylhexyl µm.5x00mm InertSustain Phenylhexyl µm.5x50mm InertSustain Phenylhexyl µm.5x50mm InertSustain Phenylhexyl µm.x0mm InertSustain Phenylhexyl µm.x50mm InertSustain Phenylhexyl µm.x75mm InertSustain Phenylhexyl µm.x00mm InertSustain Phenylhexyl µm.x50mm InertSustain Phenylhexyl µm.x50mm InertSustain Phenylhexyl µm.0x0mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm.0x75mm InertSustain Phenylhexyl µm.0x00mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm.0x50mm InertSustain Phenylhexyl µm 4.0x0mm InertSustain Phenylhexyl µm 4.0x50mm InertSustain Phenylhexyl µm 4.0x75mm InertSustain Phenylhexyl µm 4.0x00mm InertSustain Phenylhexyl µm 4.0x50mm InertSustain Phenylhexyl µm 4.0x50mm InertSustain Phenylhexyl µm 4.6x0mm InertSustain Phenylhexyl µm 4.6x50mm InertSustain Phenylhexyl µm 4.6x75mm InertSustain Phenylhexyl µm 4.6x00mm InertSustain Phenylhexyl µm 4.6x50mm InertSustain Phenylhexyl µm 4.6x50mm * End-fittings are /6 Waters-compatible.
14 Analytical Columns InertSustain Phenylhexyl 5 µm.0x0mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm.0x75mm InertSustain Phenylhexyl 5 µm.0x00mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm.5x0mm InertSustain Phenylhexyl 5 µm.5x50mm InertSustain Phenylhexyl 5 µm.5x75mm InertSustain Phenylhexyl 5 µm.5x00mm InertSustain Phenylhexyl 5 µm.5x50mm InertSustain Phenylhexyl 5 µm.5x50mm InertSustain Phenylhexyl 5 µm.x0mm InertSustain Phenylhexyl 5 µm.x50mm InertSustain Phenylhexyl 5 µm.x75mm InertSustain Phenylhexyl 5 µm.x00mm InertSustain Phenylhexyl 5 µm.x50mm InertSustain Phenylhexyl 5 µm.x50mm InertSustain Phenylhexyl 5 µm.0x0mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm.0x75mm InertSustain Phenylhexyl 5 µm.0x00mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm.0x50mm InertSustain Phenylhexyl 5 µm 4.0x0mm InertSustain Phenylhexyl 5 µm 4.0x50mm InertSustain Phenylhexyl 5 µm 4.0x75mm InertSustain Phenylhexyl 5 µm 4.0x00mm InertSustain Phenylhexyl 5 µm 4.0x50mm InertSustain Phenylhexyl 5 µm 4.0x50mm InertSustain Phenylhexyl 5 µm 4.6x0mm InertSustain Phenylhexyl 5 µm 4.6x50mm InertSustain Phenylhexyl 5 µm 4.6x75mm InertSustain Phenylhexyl 5 µm 4.6x00mm InertSustain Phenylhexyl 5 µm 4.6x50mm InertSustain Phenylhexyl 5 µm 4.6x50mm * End-fittings are /6 Waters-compatible.
15 Guard Columns for UHPLC Holder for Guard Columns for UHPLC - Guard Columns for UHPLC, Holder/Cartridge Set, Holder with pcs.5x0 mm Cartridges, InertSustain Phenylhexyl µm 80 Guard Columns for UHPLC, Holder/Cartridge Set, Holder with pcs.x0 mm Cartridges, InertSustain Phenylhexyl µm 80 Guard Columns for UHPLC, Holder/Cartridge Set, Holder with pcs.0x0 mm Cartridges, InertSustain Phenylhexyl µm Guard Columns for UHPLC,.5x0 mm, pcs, InertSustain Phenylhexyl µm Guard Columns for UHPLC,.x0 mm, pcs, InertSustain Phenylhexyl µm Guard Columns for UHPLC,.0x0 mm, InertSustain Phenylhexyl µm 80 Cartridge Guard Column Ei (on-metal) Holder for 0 mm, Cartridge Guard Column Ei - Cartridge Ei Holder/Cartridge Set, Holder with pcs.0x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Holder/Cartridge Set, Holder with pcs.x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Holder/Cartridge Set, Holder with pcs.0x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Holder/Cartridge Set, Holder with pcs 4.0x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Replacement Cartridges, pcs.0x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Replacement Cartridges, pcs.x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Replacement Cartridges, pcs.0x0 mm, InertSustain Phenylhexyl 5 µm Cartridge Ei Replacement Cartridges, pcs 4.0x0 mm, InertSustain Phenylhexyl 5 µm * End-fittings are /6 Waters-compatible.
16 Cartridge Guard Column E Holder for 0 mm, Cartridge Guard Column E Holder for mm, Cartridge Guard Column E Holder with pcs.0x0 mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs.5x0 mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs.0x0 mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs 4.0x0 mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs.0x mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs 4.0x mm Cartridges, InertSustain Phenylhexyl µm Holder with pcs.0x0 mm Cartridges, InertSustain Phenylhexyl 5 µm Holder with pcs.5x0 mm Cartridges, InertSustain Phenylhexyl 5 µm Holder with pcs.0x0 mm Cartridges, InertSustain Phenylhexyl 5 µm Holder with pcs 4.0x0 mm Cartridges, InertSustain Phenylhexyl 5 µm Holder with pcs.0x mm Cartridges, InertSustain Phenylhexyl 5 µm Holder with pcs 4.0x mm Cartridges, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs.0x0mm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs.5x0mm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs.0x0mm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs 4.0x0mm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs.0xmm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs 4.0xmm, InertSustain Phenylhexyl µm Cartridge E Replacement Cartridges, pcs.0x0mm, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs.5x0mm, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs.0x0mm, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs 4.0x0mm, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs.0xmm, InertSustain Phenylhexyl 5 µm Cartridge E Replacement Cartridges, pcs 4.0xmm, InertSustain Phenylhexyl 5 µm * End-fittings are /6 Waters-compatible.
17 GL Cart Guard Column * End-fittings are /6 Waters-compatible Holder for GL Cart Multipurpose Type - GL Cart Holder/Cartridge Set, Holder with 5 pcs Cartridges, InertSustain Phenylhexyl µm GL Cart Replacement Cartridges, 0 pcs 4.6x5 mm, InertSustain Phenylhexyl µm GL Cart Holder/Cartridge Set, Holder with 5 pcs Cartridges, InertSustain Phenylhexyl 5 µm GL Cart Replacement Cartridges, 0 pcs 4.6x5 mm, InertSustain Phenylhexyl 5 µm Conventional Guard Column Guard Column.0Xmm InertSustain Phenylhexyl µm Guard Column.0X50mm InertSustain Phenylhexyl µm Guard Column.5Xmm InertSustain Phenylhexyl µm Guard Column.5X50mm InertSustain Phenylhexyl µm Guard Column.Xmm InertSustain Phenylhexyl µm Guard Column.X50mm InertSustain Phenylhexyl µm Guard Column.0Xmm InertSustain Phenylhexyl µm Guard Column.0X50mm InertSustain Phenylhexyl µm Guard Column 4.0X0mm InertSustain Phenylhexyl µm Guard Column 4.0Xmm InertSustain Phenylhexyl µm Guard Column 4.0X50mm InertSustain Phenylhexyl µm Guard Column 4.6Xmm InertSustain Phenylhexyl µm Guard Column 4.6X50mm InertSustain Phenylhexyl µm Guard Column.0Xmm InertSustain Phenylhexyl 5 µm Guard Column.0X50mm InertSustain Phenylhexyl 5 µm Guard Column.5Xmm InertSustain Phenylhexyl 5 µm Guard Column.5X50mm InertSustain Phenylhexyl 5 µm Guard Column.Xmm InertSustain Phenylhexyl 5 µm Guard Column.X50mm InertSustain Phenylhexyl 5 µm Guard Column.0Xmm InertSustain Phenylhexyl 5 µm Guard Column.0X50mm InertSustain Phenylhexyl 5 µm Guard Column 4.0X0mm InertSustain Phenylhexyl 5 µm Guard Column 4.0Xmm InertSustain Phenylhexyl 5 µm Guard Column 4.0X50mm InertSustain Phenylhexyl 5 µm Guard Column 4.6Xmm InertSustain Phenylhexyl 5 µm Guard Column 4.6X50mm InertSustain Phenylhexyl 5 µm * End-fittings are /6 Waters-compatible.
18 Preparative Columns Max. Operating Pressure InertSustain Phenylhexyl 5 µm 6.0x50mm InertSustain Phenylhexyl 5 µm 6.0x00mm InertSustain Phenylhexyl 5 µm 6.0x50mm InertSustain Phenylhexyl 5 µm 6.0x50mm InertSustain Phenylhexyl 5 µm 7.6x50mm InertSustain Phenylhexyl 5 µm 7.6x00mm InertSustain Phenylhexyl 5 µm 7.6x50mm InertSustain Phenylhexyl 5 µm 7.6x50mm InertSustain Phenylhexyl 5 µm 0x50mm InertSustain Phenylhexyl 5 µm 0x00mm InertSustain Phenylhexyl 5 µm 0x50mm InertSustain Phenylhexyl 5 µm 0x50mm InertSustain Phenylhexyl 5 µm 4x50mm InertSustain Phenylhexyl 5 µm 4x00mm InertSustain Phenylhexyl 5 µm 4x50mm InertSustain Phenylhexyl 5 µm 4x50mm InertSustain Phenylhexyl 5 µm x50mm InertSustain Phenylhexyl 5 µm x00mm InertSustain Phenylhexyl 5 µm x50mm InertSustain Phenylhexyl 5 µm x50mm * End-fittings are /6 Waters-compatible. Guard Columns for Preparative Columns * End-fittings are /6 Waters-compatible InertSustain Phenylhexyl 5 µm 6.0x50mm Guard InertSustain Phenylhexyl 5 µm 7.6x50mm Guard InertSustain Phenylhexyl 5 µm 0x50mm Guard InertSustain Phenylhexyl 5 µm 4x50mm Guard InertSustain Phenylhexyl 5 µm x50mm Guard Cartridge Guard Columns for Preparative Columns Holder for Prep Guard Cartridge Prep Guard Cartridges, pcs 7.6x0 mm, InertSustain Phenylhexyl 5 µm Prep Guard Holder/Cartridge Set, Holder with pcs 7.6x0 mm Cartridges, InertSustain Phenylhexyl 5 µm * End-fittings are /6 Waters-compatible.
19 Capillary Columns Capillary EX-AO 0.05X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.05X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.05X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.075X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.075X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.X50mm InertSustain Phenylhexyl µm Capillary EX-AO 0.X50mm InertSustain Phenylhexyl µm Capillary EX 0.X50mm InertSustain Phenylhexyl µm Capillary EX 0.X50mm InertSustain Phenylhexyl µm Capillary EX 0.5X50mm InertSustain Phenylhexyl µm Capillary EX 0.5X50mm InertSustain Phenylhexyl µm Capillary EX 0.7X50mm InertSustain Phenylhexyl µm Capillary EX 0.7X50mm InertSustain Phenylhexyl µm EX Micro Guard (Metal) 0.Xmm InertSustain Phenylhexyl µm Capillary EX-AO 0.05x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.05x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.05x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.075x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.075x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.075x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX-AO 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.5x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.5x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.7x50mm InertSustain Phenylhexyl 5 µm Capillary EX 0.7x50mm InertSustain Phenylhexyl 5 µm EX Micro Guard (Metal) 0.xmm InertSustain Phenylhexyl 5 µm EX Micro Guard (on-metal) 0.xmm InertSustain Phenylhexyl 5 µm * End-fittings are Valco /6 (0- UF). * Valco / (6-40 UF) end-fittings are available, indicate / when ordering.
20 Worldwide Ordering Information GL Sciences, Inc. USA 47 Torrance Blvd. Suite 55 Torrance, CA 9050 Phone: Fax: Web: GL Sciences, Inc. Japan - ishishinjuku 6-Chome Shinjuku-ku, Tokyo, 6-0, Japan Phone: Fax: world@gls.co.jp Web: GL Sciences B.V. De Sleutel AS Eindhoven The etherlands Phone: + (0) Fax: + (0) info@glsciences.eu Web: International Distributors Visit our Website at The GL Sciences name, the GL Sciences logo and the following registered trademark or trademark are the property of GL Sciences Inc. Inertsil InertSustain InertSustainSwift All other trademarks or service marks are the property of their respective owners. The specification and the column type are subject to change without notice due to continual improvements.
InertSustainBio C18. Rapid Separations of Proteins and Peptides
InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight
More informationACE C18-AR Use the Power!
combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety
More informationAnalytical and Preparative SFC Columns
Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationChoosing Preparative Columns
Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical
More informationPhysical Properties. Silica
InertSustain InertSustain InertSustain is an ultra performance sugar analysis column using a weak ion-exchanger, which can be used in a ILIC mode as well. The introduction of primary amine groups prevents
More informationInertSustain Amide 技術資料
InertSustain Amide 技術資料 InertSustain Amide Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica
More informationACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability
ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles
More informationRoc On with These Dependable LC Columns
Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you
More informationSepax Technologies, Inc.
Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid
More informationEurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm
HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing
More informationUltra Columns. also available. ordering note
: 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak
More informationACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity
ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention
More informationChromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns
: 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar
More informationC30 ISOMERS HAVE MET THEIR MATCH
C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES
More informationYMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology
YMC-Triart C18 Versatile hybrid silica based HPLC Column The Selectivity Company Multi-layer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart
More informationHxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5.
Page 1 of 5 U S A HPLC Application Index Ordering Information Contact HPLC Support Silica-based columns for general separations: Separation of closely related PAH's Better retention of poorly retained
More informationUltra Columns HPLC COLUMNS
Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501
More informationAPPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit
Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,
More informationHPLC Column for Structural Isomers COSMOSIL Cholester
HPLC Column for Structural Isomers COSMOSIL ol bonded stationary phase Increased stereoselectivity Improved resolution for geometric isomers Silica Gel Average Particle Size Average Pore Size Stationary
More informationYMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology
YMC-Triart C18 Versatile hybrid silica based HPLC column The Selectivity Company Multilayer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart
More informationThermo Scientific Hypersil BDS Columns
Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific Thermo Scientific Hypersil BDS
More informationAeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE
Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance
More informationHyper-fast & Super-rugged
Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle
More informationReversed-Phase Columns (Other than ODS)
7 Reversed-Phase Columns (ther than DS) Types and characteristics of reversed-phase columns -- 9, 9 YMC-Pack Pro C8, C--------------------------- 96 YMC-Pack C 8 --------------------------------------
More informationAgilent Technologies Prep LC Columns
Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies
More informationGerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology
Gerry Hendrickx Regional Sales Manager Central Europe Developments in Waters Column Chemistries : BEH Technology XTerra Columns: First Generation Hybrid Particles Initial Launch 1999 Advantages of XTerra
More informationA New Era in SFC Column Technology
B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level
More informationA New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis
A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and
More informationPhenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,
More informationYMC HILIC Columns for Polar Analytes
YMC HILIC Columns for Polar Analytes Polar Analytes Advantages In general, reliable applications in HPLC require a minimum retention factor (k ) of 2. In the widely used reversed phase methods polar compounds
More informationApplication Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix
Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes
More informationChapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:
Chapter 22: Gas and Liquid Chromatography Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase: Ion Exchange Chromatography Page 1 of 5 Pinnacle DB Ideal for applications
More informationThe high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.
The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationLC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D
LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high
More information176 YMC Chiral Columns
176 YMC Chiral Columns YMC Chiral Columns 177 Chiral Columns Content YMC Chiral NEA(R)(S)... 178-181 YMC Chiral CD BR... 182-185 Ordering Information... 186 HPLC Columns for Optical Isomer Separation Introduction
More informationConverting a CHP Method for Insulin to Agilent Poroshell 120 Columns
Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory
More informationRestek Ultra II HPLC Columns
Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra
More informationA Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS
A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationLC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined
ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing
More informationYMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability
YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.
More informationImpurity Profiling of Carbamazepine by HPLC/UV
Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis
More informationACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available
ACE HILIC UHPLC and HPLC s For Reproducible Polar Analyte Separations Three HILIC Chemistries Available ACE HILIC s What is HILIC? Hydrophilic Interaction Liquid Chromatography (HILIC) was first described
More informationACE Excel UHPLC Columns
Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points
More informationDikma Technologies Inc.
Dikma HPLC / UHPLC Columns Selection Guide HPLC Column Selection Chart Sample MW Sample Solubility Separation Mode Dikma Recommended Column Page Fat Soluble Normal Phase Platisil NH 2 Platisil CN Platisil
More informationTransfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694
Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania
More informationFortis Method Development Options
Method Dev Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options Fortis Ho - Polar endcapped C8 - Increased
More informationNormal Phase HPLC Column COSMOSIL SL-II
Normal Phase HPLC Column COSMOSIL SL-II High purity silica gel (>99.99%) with special treatment Suitable for preparative separation Ultra-pure silica gel of more than 99.99% purity is used for the COSMOSIL
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationAm I getting the very best value from my UHPLC analyses?
Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run
More informationCore-Shell Technology for Proteins and Peptides
Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein
More informationExploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design
Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design Alan P McKeown amckeown@ace-hplc.com Advanced Chromatography Technologies www.ace-hplc.com www.mac-mod.com Outline 2 Chromatographic
More informationUltimate Core Performance to Maximize Your Investment
Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience
More informationRapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column
APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK
More informationThermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific
Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N
More informationEffective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate
Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,
More informationSeparation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column
Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based
More informationSystematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs
Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs Laura Marlatt, An Trinh, and David S. Bell Supelco, 595 North Harrison Road,
More information2 Tosoh bioscience LLc. suite 100 king of Prussia, pa 19406, USA.
TSKgel COLUMNS Tosoh bioscience gmbh Im Leuschnerpark 4 6447 Griesheim Germany t + 49 (0) 6 7047 00 f + 49 (0) 6 879 00 info.tbg@tosoh.com www.tosohbioscience.de 2 Tosoh bioscience LLc 604 Horizon Drive,
More informationAPPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.
Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually
More informationPreparative Chromatography Meets UHPLC
Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award
More informationHPLC. Varian Dynamax Preparative HPLC Columns
HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial
More informationHICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies NEW PRODUCTS Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk
More informationUCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY
UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY SELECTRA C18 HPLC COLUMNS Benefits Good choice for easily converting current C18 methods Suitable for most traditional reverse phase analyses High
More informationThe LC Column Playbook
The LC Column Playbook Mark Powell Applications Engineer Technical Support 1 Overview How do we achieve our goal: Resolution? Efficiency Particle size Column length Selectivity Bonded phase Mobile phase
More informationSUMMARY, CONCLUSION & RECOMMENDATIONS
196 Chapter-5 SUMMARY, CONCLUSION & RECOMMENDATIONS 197 CHAPTER 5 5.1 Summary, Conclusion and Recommendations Summary and Conclusion are drawn based on the work carried out by the author on development
More informationUPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationGlycanPac AXH-1 Columns
Thermo Scientific GlycanPac AXH-1 Columns Product Manual P/N: 065479-01 January 2013 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXH-1 Columns GlycanPac AXH-1, 1.9 µm, Analytical, 2.1
More informationUNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance
UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance Revolutionary aqueous durability Aqueous to non-aqueous High speed normal phase separation 3μm particle size Superior resolution
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationSimultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column
P-CN54E Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column Pittcon 5 9-6P Kenichiro Tanaka, William Hedgepeth, Yuki Sato Shimadzu Scientific Instruments,
More informationDikma Technologies Inc.
Dikma HPLC / UHPLC Columns Selection Guide Dikma Technologies Inc. www.dikmatech.com HPLC Column Selection Chart Sample MW Sample Solubility Separation Mode Dikma Recommended Column Fat Soluble Normal
More informationMeteoric Core. Core-Shell Columns for UHPLC & HPLC. Easy Method Optimization! Excellent Chromatography with Fast Separation!
Meteoric Core Easy Method Optimization! Excellent Chromatography with Fast Separation! Core Porous shell layer Meteoric Core Particle Image Structure Schöttmannshof 19 46539 Dinslaken Phone +49 (0)2064
More informationComparison of a UPLC Method across Multiple UHPLC Systems
Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid
More informationRapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit
Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent
More informationRapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases
Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin
More informationLC-Based Lipidomics Analysis on QTRAP Instruments
LC-Based Lipidomics Analysis on QTRAP Instruments Junhua Wang and Paul RS Baker SCIEX LC-Based Lipidomics Analysis Topics Covered Lipid extraction techniques Hydrophilic Interaction Chromatography (HILIC)
More informationYes You Can! New! Amazing EVO C18. Core-Shell Technology
Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used
More informationPrep Columns. and Bulk Media. and Bulk Media
Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36
More informationA New Dimension in Preparative HPLC
New Dimension in Preparative HPL... we Meet your Needs NULEODUR HTec 6 - key features: reliable and durable standard RP phase for up-scaling to preparative scale, suited for L/MS high loadability and excellent
More informationAPPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1
APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there
More informationUHPLC / HPLC Columns Developed for Mass Spectrometry
ACE UltraCore SuperC18 UHPLC / HPLC s Developed for Mass Spectrometry Water analysis Pharmaceutical Environmental Toxicology Food safety Clinical Forensics Metabolism Trace analysis Ultra-inert 2.5µm and
More informationHigh-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development
Robert Ricker Bio-Applications Scientist CABU April 5, 2 Rapid Resolution HPLC High-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development Slide 4 Ultra-Fast
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationSeparation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns
Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives
More informationGlycanPac AXR-1 Columns
CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous
More informationProfiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography
Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Application Note Metabolomics Author Yuqin Dai Agilent Technologies, Inc. 31 Stevens Creek Blvd,
More informationAnalytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP
Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract
More informationHPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction
IAM CHRMATGRAPHY IAM CHRMATGRAPHY HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction Immobilized Artificial Membrane (IAM) technology is an innovative approach
More informationFor Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.
For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies
More informationIAM Chromatography. Introduction
IAM Chromatography IAM Drug Discovery Columns Introduction References: 1. Regis 1998-99 Chromatography Catalog A simple, rapid method to predict drug transport across biological barriers has been a long
More informationCOSMOSIL HPLC Columns
COSMOSIL HPLC Columns Sample Organic Compounds (low M.W.) Reversed 3C 18 -EB L1 Octadecyl Excellent for basic compounds 3 µm silica packing material C 18 -MS-II L1 Octadecyl Multi-purpose C 18 Monofunctional
More informationStudies on Stationary Phase Selectivity for Solid-Core Particles
Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com
More information