UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system
|
|
- Denis Simon
- 6 years ago
- Views:
Transcription
1 The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases and are subject to change without prior notice. The required features should therefore be specified in each individual case at the time of conclusion of the respective contract. Printed in the UK / Nov JN4481/PN Siemens Hearing Instruments Ltd. Alexandra House Newton Road Crawley West Sussex RH10 9TT Tel: Fax: retail: info_hearingaids.shi.uk@siemens.com healthcare: siemenshearing.shi.uk@siemens.com UNITY 2 a state-of-the-art audiological integrated diagnostic and fitting system
2 UNITY 2 a state-of-the-art audiological integrated diagnostic and fitting system Hearing care professionals, and Siemens, have the same important goal: to help people with hearing loss. That s why at Siemens we continue to develop the audiological diagnostic and fitting systems hearing care professionals need for their patients. And that s why we created UNITY 2. The easy to use PC-based system allows the integration of all testing and fitting tasks, offering the power to create the best possible hearing instrument fitting. Modular, portable, in tune with your workflow. Who said state-of-the-art can t be simple to use? 2 3
3 Modular, flexible UNITY 2 s modular but integrated design means that the system can be tailored to meet individual requirements. This offers the flexibility of using all modules or different combinations of control unit and docking station. Portable The compact control unit (all housings are anodised aluminium) can be connected easily to UNITY 2 s docking station. No matter where it s needed, the UNITY 2 audiometer and REM control unit are ready to go! Simple UNITY 2 s unique, state-of-the-art design is the ultimate in simplicity. No messy wires and leads - it connects to a PC with just a single USB cable. All components have strong but simple connections. Supports your workflow It s faster: uses high-speed data links for quicker results. It s completely integrated: can be used with other Siemens systems like CONNEXX, Practice Navigator (or any other patient management system), and NOAH 3 compatible hardware or software modules. It s more efficient: all system data is stored and shared in a common database saving time and storage while eliminating data duplication. UNITY 2 supports processes from diagnostics to fitting. 4 5
4 Audiometer Module UNITY 2 s audiometer module brings together the functions of a traditional 2-channel audiometer with all the advantages of a PC-controlled audiometer. Like all UNITY 2 modules, the audiometer can be used separately. The UNITY 2 audiometer is a full 2-channel clinical system supporting conventional as well as high-frequency tone audiometry, insert earphones and complete speech testing. UNITY 2 includes ample choice of audiometric symbols (including British BSA symbols), audiogram comparison either between ears or with existing audiograms and a new silent mode panel feature to avoid unwanted signals to the patient. External input and output jacks are available to connect the audiometer modules to your PC s CD-ROM drive, a CD player or speech microphone. Also, the integrated free-field amplifier drives almost any conventional free-field speaker system. UNITY 2 Audiometer features: Complete 2-channel clinical audiometer Supports high-frequency audiometry and special test routines Capability of choosing audiogram symbols (Including British BSA symbols) Audiogram comparison either between ears or with existing audiograms Silent mode panel Fully integrates with NOAH 3 and patient management systems 6 7
5 // mobile // // stationary // Probe Microphone Module Hearing UNITY 2 is the premier fitting verification tool available today it equips the user with the power and flexibility to perform precise, accurate hearing instrument fittings, quickly and easily. The system offers the possibility to plug in two probe microphones. Integration means no double entry of audiometric data UNITY 2 takes the audiometric test information directly from the NOAH 3 database to calculate fitting targets. All standard fitting formulae are available. UNITY 2 enables the measuring of occlusion effects and the real-ear-to-coupler difference for target adjustment during paediatric fittings. In addition, the UNITY 2 probe mic module provides direct access to CONNEXX through its REM-Link, so real-time measures and adjustments on hearing instruments can be made. Instrument Analyser An adapter set is available separately and allows coupler measurements on the hearing instrument in a quiet environment Can be used without the test box making it ideal for home visits. The highly flexible tube allows quick and precise fixation of the Unity 2 probe on the customer's ear. A plug-in earpiece is integrated into the housing of the probe and enables comfortable RECD measurements even when no earpiece is available. UNITY 2 Probe Microphone features: Fully integrates with NOAH 3 and compatible patient management systems REM-Link provides real-time, simultaneous measurement and parameter adjustment of all programmable and digital Siemens hearing instruments along with our on-top mode Averaged output measurement for ICRA, ILTASS & Chirp-signals as standard Binaural probe mic Unique to UNITY 2 Sound Mapping Sound Mapping is a brand new feature in the Unity 4.6 software, enabling speech mapping by using life voice or ISTS noise (international speech test signal). The feature allows the simultaneous measurement of three curves: speech peaks, average speech and soft speech. Unity 2 is the first test system in the world to provide this unique feature! UNITY 2 s hearing instrument analyser module is a state-of-the-art hearing instrument test and measurement system. UNITY 2 provides the power and flexibility to make precise, accurate hearing instrument functionality tests including automatic routines. The software allows storage of multiple measurement curves and provides detailed text descriptions of test parameter settings, all with just the click of the mouse. A wide variety of test signals are also available, including ICRA, Chirp and ILTASS signals for testing digital hearing instruments. The extremely customisable software allows the user to adapt every single test setting to better reflect particular workflow. Analyser features: Fully integrates with NOAH 3 and Patient Management Systems Test signals for digital hearing instruments provided as standard Supports automated test routines for ANSI and IEC standards testing HIT-Link provides real-time, simultaneous measurement and parameter adjustment of all programmable and digital Siemens hearing instruments The spacious test box of the Unity 2 hearing aid analyser is situated in the docking station and offers space for coupler accessories and a Noah Link. 8 9
6 Technical Specifications Medical CE mark: The CE mark indicates that Siemens Audiologische Technik GmbH meets the requirements of Annex VI of the Medical Device Directive 93/42/EEC. Approval is made by TÜV identification no STANDARDS Safety: EMC: Hearing Instrument Analyser: Audiometer: EN , Class I, Type B EN EN , EN , EN , EN , UL ANSI S3.22. EN , ANSI S3.6, ANSI S3.43 CAN/CSA-C22.2 No M90 EN COMMON DATA FOR ALL APPLICATIONS Frequency Accuracy: ± 1 % FFT: Resolution 1024 points, Averaging: Intensity Accuracy: ± 1.5 db Sweep Speed: 1,5 12 sec./decade at 25 Hz warble frequency (depending on frequency resolution) Frequency Resolution: 1/3, 1/6, 1/12 and 1/24 octave Stimulus Distortion: Less than 1 % THD AVAILABLE TESTS Audiometer: Probe: Hearing Instrument Analyser: Air conduction REUR, OEG (Open Ear Gain) IEC118 standard (optional ANSI 3.22 standard) Bone conduction REOR (Occlusion effects) OSPL90 Free field (10 W integrated amplifier) REAR (SPL level at the eardrum) Full on gain Tests conducted other than hearing threshold: REIG (gain measured at the eardrum) Input/Output SISI test RECD (ear-to-coupler difference) Attack/Release time Lüscher test Open Ear Spectrum Reference test gain Fowler test Frequency response Stenger test Carhart test Equivalent input noise Harmonic distortion Battery current drain Custom Covers the IEC 118 and ANSI 3.22 with individual setting of the different parameters in the different tests FREQUENCY RANGE 125 Hz 8 khz (AC & free field) 125 Hz 8 khz 100 Hz 8 khz 125 Hz 16 khz (AC, HF mode) 250 Hz 6 khz (BC) STIMULUS SIGNAL Pure tone, warble, Noise signals: White, pink, speech, ILTASS, ICRA, Pure tone, warble, Noise signals: White, narrow band, speech, Chirp, patient voice Noise signals: Narrow band, chirp, ICRA ILTASS MEASUREMENT INTENSITY RANGE HDA200: db HL Microphone: db SPL Microphone: db SPL TDH39: db HL Speaker: db SPL Speaker: db SPL in 5 db step BC: db HL FF: db HL LOUDSPEAKER OUTPUT Max. 6 W into 8 ohms Max. 6 W into 8 ohms Max. 6 W into 8 ohms HEARING INSTRUMENT TEST BOX Telecoil drive in test box: Total Harmonic Distortion: Battery Simulator: Battery Current Test: ma/meter Ranges 0 55%, Resolution 0.1 % Standard types are selectable, Ranges: 0 50 ma Custom types within V, Resolution: 0.1 ma 0 25 Ohm range Accuracy: ± 5 % Computer Communication: Built-in USB1.1 computer interface. Windows software available Supported Operating Systems: Construction: Anodised all-aluminum case Windows 98 SE and higher Power: AC 50/60 Hz V (except Windows NT) Fuses: 5 x 20 mm, 2.15 AT Consumption: 75 W Dimensions: Control Unit L x W x H: 31.9 x 31.7 x 7.5 cm Docking Station L x W x H: 42.8 x 23.0 x 22.2 cm Weight: Control Unit 4.4 kg Docking Station 10.9 kg DETACHABLE PARTS OPTIONAL PARTS 2CC Coupler with adaptors for ITE, BTE Battery adapters BAA675, BAA13, BAA312, BAA10, BAA5 Reference microphone Couplers 1.2CC and 0.6CC: ITE, BTE, Body 711 coupler USB cable, power cable 120 or 230 V Operation manual and service manual multilingual CE Instructions for use 10 11
AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY
AUDIOLAB Two channel clinical audiometer Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY AUDIOLAB Two channel clinical audiometer AudioLab, advanced technology in a small package.
More informationRECD-Measurements with Connexx 6.3 and Unity 2
RECD-Measurements with Connexx 6.3 and Unity 2 Vera Spitzlei, Corporate Audiology Siemens Audiologische Technik GmbH For internal use only / Copyright Siemens AG 2009. All rights reserved. Overview Why
More informationDiagnostic Audiometer
AD629 Technical Specificatons Page 0 Technical Specifications AD629 Diagnostic Audiometer Item No.8107429 3/2015 AD629 Technical Specificatons Page 1 License Overview International configuration AD629
More informationUser groups Most sensorineural, conductive and mixed hearing losses in the categories of severe and profound.
P R O D U C T I N F O R M A T I O N S W I F T 0 + Fitting range db HL -0 0 0 0 0 0 0 Hz 0 00 0 000 00 00 General information Swift + is a very reliable and powerful programmable BTE instrument for people
More informationOscilla - excellence since 1960
Oscilla - excellence since 1960 Oscilla USB310 / 330 PC-based Screening Audiometer 11 frequencies: 125-8000 Hz (selectable in USB330) Left, right and binaural Pulse tone Warble tone (USB330) 4 automatic
More informationAA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer
Audiometer AA-MC Ideal for clinical practice in otolaryngology clinic Space saving is achieved with a width of about 350 mm Easy operation with touch panel Audiogram can be printed by built-in printer
More informationEquinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions
Equinox 2.0 PC-based audiometer Time saving solutions Equinox 2.0 PC-based audiometer The best of two worlds Equinox 2.0 is a state of the art two channel clinical audiometer controlled from an external
More informationThe integrated fitting solution
Hearing Aid Fitting The integrated fitting solution - Audiometry, REM, HIT, and visual speech mapping l e a d i n g d i a g n o s t i c s o l u t i o n s Hearing Aid Fitting A complete solution The is
More informationTWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO
TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO THE AUDIOMETER PERFECT FOR EVERY PATIENT POPULATION GSI AUDIOSTAR PRO FAST AND EFFICIENT The GSI AudioStar Pro continues the tradition of excellence in clinical
More informationThe professional fitting solution
Hearing Aid Fitting The professional fitting solution Interacoustics Hearing Aid Fitting A complete service The Affinity 2.0 is a powerful and stylish instrument that interfaces with a full range of integrated
More informationAC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer
AC40 Technical Specificatons Page 1 Technical Specifications AC40 Clinical Audiometer D-0106990-B 05/2015 AC40 Technical Specificatons Page 2 License Overview International configuration AC40 Basic license
More informationGSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard
GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full
More informationThe true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.
AC40 Clinical Audiometer true hybrid The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box Interacoustics leading diagnostic solutions AC40 Clinical Audiometer A true hybrid
More informationQuick Guide Binaural REM
Quick Guide Binaural REM The purpose of this document is to provide a quick guide for the Binaural REM feature found in the REM440 Real-Ear Measurement module in the Affinity 2.0 and Callisto Suites. This
More informationAURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04
AURICAL Plus with DSL v. 5.0b Quick Guide 0459 Doc no. 7-50-0900/04 Copyright notice No part of this Manual or program may be reproduced, stored in a retrieval system, or transmitted, in any form or by
More informationGRASON-STADLER HEARING ASSESSMENT SYSTEMS
Audiometric Solutions GRASON-STADLER HEARING ASSESSMENT SYSTEMS Setting The Clinical Standard Audiometric Solutions GRASON-STADLER HEARING ASSESSMENT SYSTEMS Clinical Systems GSI Audiostar Pro GSI AudioStar
More informationHow to use AutoFit (IMC2) How to use AutoFit (IMC2)
How to use AutoFit (IMC2) 1 AutoFit is a beneficial feature in the Connexx Fitting Application that automatically provides the Hearing Care Professional (HCP) with an optimized real-ear insertion gain
More informationThe true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.
AC40 Clinical Audiometer true hybrid The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box Interacoustics leading diagnostic solutions AC40 Clinical Audiometer A true hybrid
More informationFONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech
FONIX FP35 Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Move your hearing aid fittings into the world of the touch screen! The new FP35 Touch adds a new interactive dimension to hearing
More informationAC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s
AC40 Clinical Audiometer Save time Focus on results Interacoustics l e a d i n g d i a g n o s t i c s o l u t i o n s AC40 Clinical Audiometer Two channel audiometer The AC40 is an advanced clinical audiometer
More informationAUDIOMETERS AUDIXI 10
AUDIOMETERS AUDIXI 10 DESCRIPTION The Audixi 10 is a Two-Channel innovative digital audiometer with Internet connectivity leveraging the Tablet technology and incorporating a new and simplified calibration
More informationAC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11
AC40 Technical Specificatons Page 1 Technical Specifications AC40 Clinical Audiometer D-0106990-F 2017/11 AC40 Technical Specificatons Page 2 License Overview International configuration AC40 Basic license
More informationNeuro-Audio Version 2010
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE ECochG MLR P300 Neuro-Audio Version 2010 one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA)
More informationAT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.
AT235/AT235h Middle Ear Analyzers Diagnostic & clinical tympanometry with basic audiometry. Fast & reliable middle ear analyzer The AT235 is an automatic middle ear analyzer ideal for diagnostic and screening
More informationAD226 Diagnostic Audiometer
AD226 Technical Specificatons Page 0 Technical Specifications AD226 Diagnostic Audiometer D-0106126-C 2017/11 AD226 Technical Specificatons Page 1 License Overview International configuration AD226 Basic
More informationmyaudiometer. It s familiar, and it s so much
Introducing the MADSEN Astera myaudiometer. It s familiar, and it s so much More 2 I m amazed that I can do so much more without changing the way I work. myaudiometer. It s familiar. Just more... Possibilities
More informationTesting Digital Hearing Aids
Testing Digital Hearing Aids with the FONIX 6500-CX Hearing Aid Analyzer Frye Electronics, Inc. Introduction The following is a quick guide for testing digital hearing aids using the FONIX 6500-CX. All
More informationAudiology Equipment p r o d u c t s c AtA l o g u E
products catalogue 2014 Audiology Equipment Orchestral perfection A full line of Audiology Equipment News for 2014 Our Bell, Harp and Piano audiometers now feature HyTech, Inventis Hybrid Technology. You
More informationDSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.
www.bestsound-technology.com DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015. First fit is an essential stage of the hearing aid fitting process and is a cornerstone of the ultimate
More informationEquinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution
Equinox 2.0 PC-based audiometer Not just an audiometer - A full counseling and reporting solution The PC-based Advantage The Equinox 2.0 is a state of the art two channel clinical audiometer. Counseling
More informationThe future of fitting
The future of fitting She s looking at you and you re looking at her The new AURICAL makes her fitting experience more comfortable, faster and easier to understand. It helps you create rapport and gain
More informationAD629 The true hybrid
AD629 The true hybrid Stand alone & PCbased audiometry in one box The first true hybrid audiometer The AD629 presents a new concept we like to call hybrid, because it combines the best of past, present
More informationThe true hybrid Stand alone & PC-based audiometry in one box
AD629 Diagnostic Audiometer true hybrid The true hybrid Stand alone & PC-based audiometry in one box Interacoustics leading diagnostic solutions AD629 Diagnostic Audiometer The first true hybrid audiometer
More informationGSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER
GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER Setting The Clinical Standard GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER Tradition of Excellence The GSI AudioStar Pro continues the tradition of
More informationABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300 Neuro-Audio one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA) (air and
More informationINTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.
INTRODUCTION TO PURE TONE AUDIOMETERY (AUDIOMETER & TESTING ENVIRONMENT) By Mrs. Wedad Alhudaib with many thanks to Mrs. Tahani Alothman Topics : This lecture will incorporate both theoretical information
More informationImportance of a Good Start. Topics. Rationale. In-Situ Audiometry. In-Situ Audiometry. Enhancing the Initial
Enhancing the Initial Hearing Aid Fitting Michael Block, Ph.D. Session 0228 Importance of a Good Start The consequences of doing a poor job of selling the hearing-impaired client on a positive treatment
More informationThe true hybrid Stand alone & PC-based audiometry in one box
true hybrid The true hybrid Stand alone & PC-based audiometry in one box l e a d i n g d i a g n o s t i c s o l u t i o n s The first true hybrid audiometer The presents a new concept we like to call
More informationAC40. The true clinical. hybrid
AC40 The true clinical hybrid The true clinical hybrid audiometer Stand alone & PCbased audiometry in one box A true hybrid audiometer The AC40 full two channel audiometer includes all the advanced features
More informationAA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions
AA222 / AA220 Audio Traveller Save time on routine. Focus on results. AA222 / AA220 Audio Traveller Middle ear analyzer The AA222/AA220 is the most comprehensive combination of middle ear analyzer and
More informationGood Things Come In Small Packages. Diagnostic & Hearing Instrument Fitting Technologies CATALOG
Good Things Come In Small Packages Diagnostic & Hearing Instrument Fitting Technologies CATALOG Good Things Come In Small Packages MedRx, Inc 1200 Starkey Rd. #105 Largo, FL 33771 U.S.A. 888-392-1234 727-584-9600
More informationSoftware Training Manual
Software Training Manual Copyright June 2004 Avant Training Manual Rev 1 Effective Date June 1, 2004 INTRODUCTION Congratulations! Your decision to incorporate the MedRx Avant into your daily practice
More informationbinax fit: How it s simulated in Connexx, how to verify it, and how to match-to-target the easy way
www.bestsound-technology.com binax fit: How it s simulated in Connexx, how to verify it, and how to match-to-target the easy way Richard Schultz-Amling Sivantos, 2015. 1 Introduction Since the release
More informationHearing Solutions Catalog Winter Supplement January 2009
Hearing Solutions Catalog Winter Supplement January 2009 LX Virtue The following information is a supplement containing information for products released January 1, 2009. It should be used along with
More informationGeneral about Calibration and Service on Audiometers and Impedance Instruments
General about Calibration and Service on Audiometers and Impedance Instruments Calibration and Service of Audiometers - page 1 of 14 Rev.4 2008-05-21/JF General about Calibration and Service on Audiometers
More informationPortable Hearing Instrument Fitting System
Portable Hearing Instrument Fitting System TM TM The RM500SL delivers real control and portable verification. Now you can provide Audioscan quality patient care wherever it s needed! The RM500SL is used
More informationChildFit. Widex Baby. Compass quick guide
ChildFit When working with very young children, it is not always possible to obtain all of the information necessary for an accurate hearing aid fitting. To that end, Widex has developed the ChildFit procedure
More informationAMBCO 1000+P AUDIOMETER
Model 1000+ Printer User Manual AMBCO 1000+P AUDIOMETER AMBCO ELECTRONICS 15052 REDHILL AVE SUITE #D TUSTIN, CA 92780 (714) 259-7930 FAX (714) 259-1688 WWW.AMBCO.COM 10-1004, Rev. A DCO 17 008, 11 13 17
More informationContents #
TRAINING MANUAL Contents Introduction... 3 AVANT REMsp Software Overview..... 3 AVANT REMsp Software Options.... 4 Preparing for Testing.. 8 Live Speech Mapping.. 11 Real Ear Measurements. 16 Additional
More informationDiagnostic Impedance & Audiometry in one solution
AA222/AA222h Audio Traveller Diagnostic Impedance & Audiometry in one solution Interacoustics l e a d i n g d i a g n o s t i c s o l u t i o n s AA222/AA222h Audio Traveller Middle ear analyzer The AA222
More informationOIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R
More informationIntroduction... 3 AVANT REM Software Overview... 4
TRAINING MANUAL Contents Introduction... 3 AVANT REM Software Overview... 4 AVANT REM Software Options... 5 Preparing for Testing... 8 Live Speech Mapping.... 12 Real Ear Measurements 17 Additional Tests
More informationAffinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping
Affinity 2.0 integrated fitting solution Audiometry, REM, HIT, and Visible Speech Mapping The complete solution Affinity 2.0 is a user friendly, all-in one system for audiometry, real-ear measurement and
More informationER75 Electro-Acoustic Ear Simulator. Operating Manual
ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United
More informationTRAINING MANUAL
TRAINING MANUAL www.medrx-usa.com 1 Contents Introduction..... 3 AVANT REM Software Overview.... 4 AVANT REM Software Options... 5 Preparing for Testing.... 8 Live Speech Mapping... 12 Real Ear Measurements.....
More informationAMBCO AUDIOMETER
Model 1000+ User Manual AMBCO 1000+ AUDIOMETER AMBCO ELECTRONICS 15052 REDHILL AVE SUITE #D TUSTIN, CA 92780 (714) 259-7930 FAX (714) 259-1688 WWW.AMBCO.COM 10-1003, Rev. A DCO 17 008, 11 13 17 Model 1000+
More informationThe Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements
The Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements By: Kristina Frye Section 1: Common Source Types FONIX analyzers contain two main signal types: Puretone and
More informationEPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE
EPIC-PLUS System for auditory evoked potentials and neuro-otology PEA - VEMPs ASSR - E-ABR FACIAL NERVE EPIC-PLUS System for auditory evoked potentials and neuro-otology Epic-plus, a unique solution. With
More informationDesktop Fitting Guide for Phonak Brio 3
Phonak Target 5.3.3 Desktop Fitting Guide for Phonak Brio 3 The Phonak Target fitting software is intended to be used by qualified hearing care professionals to configure, program, and fit hearing aids
More informationDSM PRO. Software Training Manual. Copyright November 2003
DSM PRO Software Training Manual Copyright November 2003 DSM PRO Training Manual Rev 1 Effective November 2003 INTRODUCTION Congratulations! Your decision to incorporate the MedRx DSM PRO into your daily
More informationMedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator
MedRx HLS Plus An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid Hearing Loss Simulator The Hearing Loss Simulator dynamically demonstrates the effect of the client
More informationFONIX FA-12 Hearing Evaluator Digital Audiometer
FONIX FA-12 Hearing Evaluator Digital Audiometer Operator s Manual version 1.22 2011, Frye Electronics, Inc. All Rights Reserved 6/09 Revised 4/27/11 Note on this Manual We have organized this manual
More informationThe true hybrid Stand alone & PC-based audiometry in one box
ad629 Diagnostic Audiometer true hybrid The true hybrid Stand alone & PC-based audiometry in one box Interacoustics l e a d i n g d i a g n o s t i c s o l u t i o n s ad629 Diagnostic Audiometer The first
More informationThis Page Intentionally Left Blank
TRAINING MANUAL This Page Intentionally Left Blank 2 Contents Introduction... 4 AVANT REM Speech Software Overview. 5 AVANT REM Speech Software Options 6 Preparing for Testing.. 9 Live Speech Mapping..
More informationPhonak Target 6.0. Phonak Target Fitting Guide. Content. November 2018
Phonak Target 6.0 November 2018 Phonak Target Fitting Guide The Phonak Target fitting software is intended to be used by qualified hearing care professionals to configure, program, and fit hearing aids
More informationA full product range for your every need. World leading diagnostic solutions
A full product range for your every need World leading diagnostic solutions Future-safe solutions based on knowledge For more than 45 years, Interacoustics has helped the professional world reach new milestones
More informationABR Screener Excellence in Newborn Hearing Screening
MB 11 Patented CE-Chirp stimulus reduces test times Virtually no cost or low cost supplies reduce program costs Classic and BERAphone hardware models offer choices to meet your program needs ABR Screener
More informationThe registration testing for audiometric device in CFDA
The registration testing for audiometric device in CFDA Beijing Center for Medical Devicee Quality Supervision and Testing of China Food and Drug Administration Beijing Institute of Medical Device Testing
More informationVerification of soft speech amplification in hearing aid fitting: A comparison of methods
Verification of soft speech amplification in hearing aid fitting: A comparison of methods Sarah E. Dawkins, B.A. AuD Research Project April 5, 2007 University of Memphis Project Advisor Robyn M. Cox, PhD.
More informationOperating Instructions MA 25
Operating Instructions MA 25 Table of Contents Page 1 Introduction... 2 2. Description... 3 2.1 Important safety note... 4 2.2 Unpacking and checking the MA 25... 5 2.3 Accessories... 5 2.5 Connecting
More informationPhonak Target 4.3. Desktop Fitting Guide. Content. March 2016
Phonak Target 4.3 March 2016 Desktop Fitting Guide This guide provides you with a detailed introduction to latest hearing instrument fitting with Phonak Target. www.phonakpro.com/target_guide Please also
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Equipment for speech audiometry Appareils pour l audiométrie vocale OIML R 122 Edition 1996 (E) CONTENTS Foreword... 3
More information보청기의전기음향적성능분석. Kyoung Won Lee, Ph.D Hallym University of Graduate Studies
보청기의전기음향적성능분석 Kyoung Won Lee, Ph.D Hallym University of Graduate Studies 차례 I. 성능분석이필요한이유 II. 성능분석에필요한장비의구성 III. 성능분석시구성품의위치 IV. 성능분석의기준 V. 성능분석의내용 VI. 성능분석의절차 I. 성능분석이필요한이유 보청기의품질관리보청기의적합 - frequency
More informationpep Step up with pep Pep Specification Guide _Pep_Specification_Guide_UK.indd 1
pep Step up with pep Pep Specification Guide 124843_Pep_Specification_Guide_UK.indd 1 20.06.12 14:14 What is pep? It s that energetic feeling you get when life is great and you are ready to take on the
More informationBuilding Practice Success Through Speechmap Real Ear Measurements. Chris Stokes-Rees
Building Practice Success Through Speechmap Real Ear Measurements Chris Stokes-Rees Speaker Disclosure Relevant financial relationships: Audioscan (Applications Specialist) Conestoga College, Kitchener
More informationERO SCAN. Otoacoustic Emission Testing
ERO SCAN Otoacoustic Emission Testing ERO SCAN OAE Testing for all ages Newborns School Children Toddlers Adults ERO SCAN Screening Version The ERO SCAN with screening function is the smart choice for
More informationPhonak Target 5.4. Phonak Target Fitting Guide. Content. August 2018
Phonak Target 5.4 August 2018 Phonak Target Fitting Guide The Phonak Target fitting software is intended to be used by qualified hearing care professionals to configure, program, and fit hearing aids to
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The first and only one of its kind 4
More informationTRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.
TRAINING MANUAL AVANT Hearing Instrument Test Chamber HIT+ www.medrx-int.com Contents Getting to know your HIT+... 3 AVANT HIT Software Overview.. 4 AVANT HIT Software Options.... 5 Preparing for Testing...
More informationUnlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G
OAE AUDIOMETRY Unlock VIDEO OTOSCOPY N O A H IMC2 AND EMR READY C O U N S E L I N G IMMITTANCE R E P O R T I N G H I T P M M your potential Otometrics Madsen A450 the audiometer that works for you Fits
More informationStep-by-Step RECD Guide
Precision Audiometric Instruments www.medrx-usa.com Step-by-Step RECD Guide The RECD task involves 4 steps: 1 - Complete Calibration of the Speakers and Probe Tube 2 - Measure an Ear Response 3 - Perform
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device. Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationTune in on life with SCOLAbuddy. A new fm receiver from Widex
Tune in on life with SCOLAbuddy A new fm receiver from Widex Meet your new buddy The latest member of the Scola FM family The successful Widex SCOLA FM product series has acquired a new family member:
More informationBioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY
BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY 2017/2018 CONTENT OVERVIEW GUIDELINE WITH FUNCTIONAL ANALYSIS AUDIOMETRY eaudio USB MIDDLE EAR ANALYSIS etymp USB EVOKED POTENTIALS
More informationERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols
ERO SCAN Screener with 4 frequency DPOAE testing Protocols Diagnostic with 4, 6 and 12 frequency DPOAE testing Protocols *TEOAE upgrade OAE Test System ERO SCAN - OAE Test System Physicians Otoacoustic
More informationProduct Portfolio Supplement
2016 Product Portfolio Supplement I N T R O D U C I N G Muse BTE 13 The latest release in the Muse family Made for At Starkey Hearing Technologies, we ve always focused on audibility and speech understanding
More informationFM SYSTEMS. with the FONIX 6500-CX Hearing Aid Analyzer. (Requires software version 4.20 or above) FRYE ELECTRONICS, INC.
T E S T I N G FM SYSTEMS with the FONIX 6500-CX Hearing Aid Analyzer (Requires software version 4.20 or above) FRYE FRYE ELECTRONICS, INC. P.O. Box 23391 Tigard, OR 97281-3391 (503) 620-2722 (800) 547-8209
More informationAudiological Bulletin no. 46
Audiological Bulletin no. 46 Fitting Passion 115 with Compass V4 News from Audiological Research and Communication 9 502 1119 001 10-07 2 This bulletin describes the four main steps in fitting Passion
More informationAffinity 2.0 / Equinox 2.0 Hearing Aid Analyzer
Instructions for Use US Affinity 2.0 / Equinox 2.0 Hearing Aid Analyzer D-0004578-J 2017/11 Instructions for Use - US Hearing Aid Analyzer Affinity 2.0 Table of Contents 1 INTRODUCTION... 1 1.1 About
More informationECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR
ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR Screening and Clinical Modality User Programmable Protocols ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR All of Labat s technology
More informationExperience the power of integration
Experience the power of integration Contact us: 1 800 289 2150 sales@gnotometrics.com www.otometrics.com Specifications are subject to change without notice. Copyright GN Otometrics. 2013/03. 7-26-9055-US/00.
More informationPrecision Audiometric Instruments
Audiometry REM/Live Speech Mapping H earing Instrument Testing & Evaluation Tinnitus Assessment Video Otoscopy Hearing Instrument Vacuum www.medrx-usa.com Precision Audiometric Instruments Precision Audiometric
More informationOAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols
Screener PLUS with 4 frequency DPOAE testing Protocols Diagnostic PLUS with 4, 6 and 12 frequency DPOAE testing Protocols *TEOAE upgrade OAE Test System Physicians Otoacoustic emissions testing is an ideal
More informationPrecision Audiometric Instruments
Audiometry REM/Live Speech Mapping H earing Instrument Testing & Evaluation Tinnitus Assessment Video Otoscopy Hearing Instrument Vacuum www.medrx-usa.com Precision Audiometric Instruments MedRx Gives
More information