RESEARCH ARTICLE /jp-journals

Size: px
Start display at page:

Download "RESEARCH ARTICLE /jp-journals"

Transcription

1 /jp-journals RESEARCH ARTICLE Parikshit Rajkumar Rao et al Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop for en masse Retraction of Anterior Teeth: FEM Study 1 Parikshit Rajkumar Rao, 2 Sunita S Shrivastav, 3 Rishi A Joshi ABSTRACT Introduction: M/F ratio, F/D rate, amount of force produced and the configuration of a loop affects the complex biomechanics involved in a translatory type of tooth/teeth movement for closure of extraction space. Aim: To evaluate the biomechanical properties of snail loop and compare it with teardrop loop and opus loop. Materials and methods: Finite element method analysis was carried out by utilizing Ansys10 and 11software in a computer loaded with IBM. A total of 13 finite element models were constructed and 14 analyses were conducted in the study. Results: Inherently the M/F ratio produced was higher and F/D rate produced was least for opus loop compared to snail loop and teardrop loop. Conclusion: With incorporation of 20 gable bends snail loop prepared in inch and inch TMA wire is very efficient to deliver M/F ratio required for translatory tooth movement with acceptable F/D rate. Snail loop is easy to fabricate and finer shape morphology prevents tissue impingement. Keywords: Snail loop, Opus loop, Teardrop loop, FEM. How to cite this article: Rao PR, Shrivastav SS, Joshi RA. Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop for en masse Retraction of Anterior Teeth: FEM Study. J Ind Orthod Soc 2013;47(2): INTRODUCTION Space closure forms a major fraction of orthodontic treatment. Extraction space closure is carried out by retraction of anteriors or protraction of posteriors, depending upon the type of anchorage requirements. 1 Modus operandi for closure of extraction spaces in preadjusted edgewise appliance therapy are: Friction mechanics or frictionless mechanics. 2 The advantage of frictionless mechanics is that there is no dissipation of force by friction. Various retraction loops, such as teardrop, opus, etc. are used as force system in frictionless mechanics. In retraction loop mechanics the only known disadvantage is that, the loop may fail to produce ideal expected results in practice due to the complexity of loop fabrication and some unknown factors. The force system of retraction 1,3 Senior Lecturer, 2 Professor 1 Department of Orthodontia, KM Shah Dental College, Vadodara Gujarat, India 2 Department of Orthodontics, Sharad Pawar Dental College, Wardha Maharashtra, India 3 Department of Orthodontics, Hitkarini Dental College, Jabalpur, Madhya Pradesh, India Corresponding Author: Parikshit Rajkumar Rao, Senior Lecturer Department of Orthodontia, KM Shah Dental College, Vadodara, Gujarat India, raoparikshit83@yahoo.in Received on: 3/3/12 Accepted after Revision: 25/8/12 62 loops can be tested in the laboratory and the clinician can then fabricate the spring in accordance. 2,3 The retraction loop should have an optimum size to fit into the vestibule causing no discomfort to the patient and must be easy to fabricate. For a translatory tooth movement, retraction loop should provide sufficiently high moment-to-force (M/F) ratio and low force to deflection (F/D) rate to maintain optimum force levels for a longer duration of time. 4 Keeping these clinical considerations into mind; clinicians have proposed a variety of clinical modifications in the design of the loop, degree of bends, type, dimension and material of an archwire. Teardrop loop 5 is very simple to fabricate, but the inherent M/F ratio of loop is inadequate for causing translatory motion of the teeth. Opus loop design inherently produces M/F ratio close to 10:1. 6 One major disadvantage with this retraction loop is the tissue impingement caused by it. A blend of both the designs is seen to be integrated in snail loop. 7 It has got design configuration similar to teardrop loop and additionally has got a helix in its design similar to opus loop. For any retraction loop to be made universally acceptable a complete knowledge of its biomechanical properties are very essential. Literature search revealed that the biomechanical efficiency of snail loop has not yet been analyzed. Present study evaluates the biomechanical efficiency of snail loop and compares it to that of teardrop loop and opus loop which are frequently used for en masse space closure. MATERIALS AND METHODS Mathematical approach and experimental methods are routinely used for analyzing M/F ratio and F/D rate of loop JAYPEE

2 JIOS Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop designs. 8,9 Laser holography, 10 photoelastic models/typodont 11 are various experimental approaches that routinely utilized by clinicians for extensive analysis of retraction loops. Since the above mentioned experimental approaches are time consuming and expensive, presently finite element method (FEM), which is observed to be used extensively to study loop designs, was used for this study. 6 Ansys V10 and V11 finite element software was used to construct a three-dimensional model of the retraction loops after which forces and moments produced by loop geometries in all three-dimensions were studied. A computer loaded with IBM consisting of Ansys as the pre- and postprocessor and Ansys direct solver which investigated the three-dimensional outcome of individual loops were used in the study. Based on the dimensions prescribed by the respective authors (Figs 1 to 3) a total of 13 FEM models were constructed and 14 analyses were conducted in the study. 5-7 The horizontal length of all the loop models (distance between the anterior and the posterior node) were kept 13 mm considering the interbracket distance from the second premolar midpoint to the canine midpoint considering a first premolar extraction case (Figs 4 to 7). Titanium molybdenum alloy (TMA) and stainless steel (SS) are the most commonly used wires for making loops. Most of the loop mechanics advocate full slot engagement and most Fig. 3: Dimensions of opus loop used for modeling often preferred wire dimension is inch and inch wire dimensions. Any variation in the material of wire produces a different F/D rate. Hence we chose both TMA and SS wires of both inch and inch wire dimensions. Following 13 FEM models were prepared for the study: Three models for snail loop were prepared in inch TMA wire with 0, 10 and 20 preactivation bends. Two models for snail loop were prepared in inch SS wire with 0 and 10 preactivation bend. Four models for snail loop were prepared in inch TMA wire with 0, 5, 10 and 20 preactivation bends. Two models of snail loop were prepared in inch SS wire with 0 and 10 preactivation bend. One model each of teardrop loop and opus loop was generated in inch TMA wire without any preactivation bends. Method of Analysis for Different Combinations of FEM Model 1. Loops without preactivation bend: A fixed point was determined at the terminal node on the alpha side Fig. 1: Dimensions of teardrop loop used for modeling Fig. 2: Dimensions of snail loop used for modeling Fig. 4: FEM model prepared for teardrop loop without any preactivation bend The Journal of Indian Orthodontic Society, April-June 2013;47(2):

3 Parikshit Rajkumar Rao et al 2. Loops with preactivation bend: To simulate the engagement of the wire in the brackets a rotation was added to the alpha end until the horizontal leg was completely horizontal and collinear with the bracket slot. The exact displacement at the alpha node was recorded to obtain information about the amount of cross-over produced when the wire was engaged. This point was neutral position for all the loops and starting point for all the activations. Subsequently the terminal node on the beta side was displaced by a predetermined distance after which the force and the moment produced on the terminal node on the alpha side were recorded. RESULTS Fig. 5: FEM model prepared for opus loop without any preactivation bend Fig. 6: FEM model prepared for snail loop prepared without any preactivation bend Fig. 7: FEM model prepared for snail loop prepared with preactivation bend on side (corresponding to the canine bracket) on the FEM model. Subsequently the terminal node on the beta side (corresponding to the second premolar bracket) was displaced by a predetermined distance after which the force and the moment produced on the terminal node on the alpha side were recorded on the Ansys software. Finite element analysis was carried out for different FEM models and MCSPD code was given to different models prepared, where: M represents material types (TMA or SS) C represents configurations of loops (teardrop, Tr, opus, Op and snail, Sn loops) S represents size of wire ( inch as S1 and inch as S2) P represents preactivation angle alpha (zero degree as 0, five degrees as 5, ten degrees as 10, twenty degrees as 20 ) D represents displacement, the amount of activation of the given loop model (1 mm as D1 and 2 mm as D2). Total 13 FEM models were studied to evaluate the M/F ratio, F/D rate and the maximum force generated by the respective loop models after their activation. Results of the study are tabulated as shown in Tables 1 to 3. DISCUSSION This study was designed to optimize the utilization of snail loop by understanding its biomechanical properties and also compare it with opus and teardrop loop. It was observed that the forces, moments and F/D rate produced from SS dental archwire was nearly three times in comparison to TMA. However, the changes observed in M/F ratio was not appreciable when SS and TMA was compared (Tables 1 and 2). When dimension of wires was changed from S1 to S2 in TMA wire a marginal increase in force produced and F/D rate was observed. In SS archwire when the dimension of wires was changed from S1 to S2 wire increase in force produced and F/D were substantial (Tables 1 and 2). Bodily tooth movement requires production of uniform stress on PDL with a light continuous force. 12 The inherent M/F ratio produced by snail loop is not adequate to impart translatory movement of the dentition. To increase the M/F ratio gable/preactivation bends have to be incorporated into the loop. Snail loop prepared in either TMA or SS archwire produced optimum M/F ratio for bodily movement after giving 20 preactivation bend (Tables 1 and 2). 64 JAYPEE

4 JIOS Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop F/D rate produced by snail loop models prepared in TMA wire was comparatively less when compared to models prepared in SS wire (Tables 1 and 2). This observation was further substantiated in Graph 1. Reason for such an observation could be attributed to various physical properties exhibited by TMA wire. 13 This is an important observation as loops with high F/D rate tend to deactivate faster and can exert stresses up to a level which can be traumatic to the periodontium and alveolar bone. Lower F/D ratio delivers a constant force as the tooth moves and the appliance gets deactivated late in comparison to loops producing higher F/D ratio. 13 For individual bodily canine retraction a force of 150 and 300 gm for anterior retraction is recommended. 14 A force level of 70 to 120 gm is needed for bodily movement of the dentition. 15 Force level of 100 gm is recommended for incisor retraction on each side. 16 A force range of 320 to 350 gm for upper anteriors and 270 to 290 gm is required for lower anteriors. 17 A force level of 200 gm for en mass retraction for frictional mechanics has been recommended. 18 Snail loop model prepared in TMA wire with dimension of S2 having 20 bend produced maximum force of 339 gm after D2 displacement, snail loop model prepared in TMA wire with dimension of S1 having 20 preactivation bend produced a maximum force of gm after D2 displacement. These loop models provided ideal force levels with acceptable M/F ratio. Forces produced by models prepared in stainless steel were very high (Tables 1 and 2). TMA wires delivered more constant moments throughout the range of deflection and thus the center of rotation of the dentition was kept constant throughout the range of tooth movement (Graph 2). Several factors related both to the thermomechanical processing of the wire and the larger elastic range, which requires a different bending technique, could justify this finding. 13 Hence, TMA loops are more preferable due to their larger range and more consistent force delivery. Comparison between snail, teardrop and opus loop prepared in S2 dimension in TMA wire without giving any preactivation bend at D1 displacement showed that M/F ratio of opus loop was 9.8 mm, teardrop loop was 4.5 mm and for snail loop was 5.5 mm (Table 3). The M/F ratio produced by all the loop models was constant throughout the period of activation (Graph 3). Thus, we can observe that inherently opus loop produces an ideal M/F ratio required for bodily translation of the dentition. The height of the opus loop being more as compared Table 1: Comparison of snail loop prepared in SS and TMA wires in S1 dimension Material of Preactivation Force produced at Moments produced at F/D rate at M/F ratio at the wire bend ( ) displacement D1 displacement D1 displacement D1 displacement and D2 (gm) and D2 (gm/mm) and D2 (gm/mm) D1 and D2 (mm) 1 (mm) 2 (mm) 1 (mm) 2 (mm) 1 (mm) 2 (mm) TMA SS Table 2: Comparison of snail loop prepared in SS and TMA wires in S2 dimension Material of Preactivation Force produced at Moments produced at F/D rate (gm/mm) M/F ratio at the wire bend ( ) displacement D1 displacement D1 displacement D1 and D2 (gm) and D2 (gm/mm) and D2 (mm) 1 (mm) 2 (mm) 1 (mm) 2 (mm) 1 (mm) 2 (mm) TMA SS Table 3: Comparison of snail, opus and teardrop loops prepared in TMA wire with dimension of S2 Loop configuration Preactivation Initial Force produced Moments F/D rate M/F ratio (mm) bend ( ) displacement at 1 mm produced (gm/mm) (mm) displacement at 1 mm (gm) displacement (gm/mm) Snail loop (TM, Sn, S2, 0, D1) Tear drop loop (TM, Tr, S2, 0, D1) Opus loop (TM, Op, S2, 0, D1) The Journal of Indian Orthodontic Society, April-June 2013;47(2):

5 Parikshit Rajkumar Rao et al to the other two loops contributes to the increase observed in the M/F ratio. This increased height of the opus loop can create problem of tissue impingement and reduce patient compliance. F/D rate and maximum force generated of opus loop is the lowest compared to other two loops (Table 3). Configuration of the opus loop and 70 angulation given to its vertical leg during optimization of the design could be attributed to such an observation. CONCLUSION Thus after evaluating and comparing all the characteristics of teardrop loop, opus loop and snail loop we conclude that snail Graph 1: Comparison of F/D rate for snail, opus and teardrop loops prepared in S1 and S2 dimensions of wire Graph 2: Comparison of moment to displacement curve for snail, opus and teardrop loops prepared in S1 and S2 dimensions of wire Graph 3: Comparison of M/F ratio produced by snail, opus and teardrop loops prepared in S1 and S2 dimensions of wire 66 JAYPEE

6 JIOS Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop loop has a definite advantage over teardrop loop in all respects of biomechanical characters. Snail loop with incorporation of gable bends is very efficient to deliver M/F ratio similar to that of opus loop. Finer shape morphology of snail loop provides ease of fabrication and prevents tissue impingement which is a drawback of opus loop. For optimum utilization of snail loop it must be prepared in either inch or inch TMA wire and must be activated by 2 mm. No matter how precise we try to conduct our study we cannot specifically simulate and construct an artificial oral environment to conduct a study. Hence, a further assessment on the clinical efficiency and ease of use of snail loop on patients has to be conducted. REFERENCES 1. Braun S, Sjursen RC, Legan HL. On management of extraction site. Am J Orthod Dentofacial Othop 1997;112: Staggers JA, Germane N. Clinical considerations in the use of retraction mechanics. J Clin Orthodont 1991 June;25(6): Choy K, Pae E-K, Kim KH, Park YC, Burstone CJ. Controlled space closure with a statically determinate retraction system. Angle Orthodont 2002;72: Burstone CJ, Koeng HA. Optimizing anterior and canine retraction. Am J Orthod 1976;70(1): Alexander AG. The vari-simplex discipline: Part-3 extraction treatment. J Clin Orthodont 1983 Aug; Siatowski RE. Continuous archwire closing loop design optimization and verification. Part 1. Am J Orthod Dentofac Orthop 1997;112: Vibhute PJ. Snail loop for low friction space closure. J Clin Orthodont 2008;42: Rinaldi TC, Johnson BE. An analytical evaluation of a new spring design for segmented space closure. Angle Orthod 1995;65: Nagerl H, Burstone CJ. Centre of rotation with transverse forces: An experimental study. Am J Orthod Dentofacial Orthop 1991;99: Burstone CJ, Pryputiniewicz RJ. Holographic determination of the centre of rotation produced by orthodontic forces. Am J Orthod Dentofac Orthop 1980 Apr;77(4): Baetin LR. Canine retraction. A photoelastic study. Am J Orthodont 1975;67(1): Mazza D, Mazza M. Specialized spring design in segmented edgewise mechanics: Further verification of dedicated software. Angle Orthodont 200;70: Rabound DW, Faulkner MG, Lipset AW. Three-dimensional effect in retraction appliance design. Am J Orthod Dentofacial Orthop 1997;112: Fortin J-M. Translation of premolars in the dog by controlling the moment to force ratio on the crown. Am J Orthodont 1971;59(6): Proffit WR, Fields HW. The second stage of comprehensive treatment: Correction of molar relationship and space closure. Section 7 of Chapter 17. Contemporary Orthodontics (3rd ed). St Louis, Missouri: Mosby 2001: Gjessing P. Controlled retraction of maxillary incisors. Am J Orthod Dentofacial Orthop 1992;101: Hixon EH, Tikian HA, Callow GE, McDonald HW, Tacy RJ. Optimum force, differential force and anchorage. Am J Orthodontics 1969;55(1): Bennet JC, McLaughlin RP. Controlled space closure with a preadjusted appliance system. J Clin Orthodont 1990;24; The Journal of Indian Orthodontic Society, April-June 2013;47(2):

Controlled Space Closure with a Statically Determinate Retraction System

Controlled Space Closure with a Statically Determinate Retraction System Original Article Controlled Space Closure with a Statically Determinate Retraction System Kwangchul Choy, DDS, MS, PhD a ; Eung-Kwon Pae, DDS, MSc, PhD b ; Kyung-Ho Kim, DDS, MS, PhD c ; Young Chel Park,

More information

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One In italiano, per favore ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS Part One Gabriele Floria DDS, Lorenzo Franchi DDS, Turi Bassarelli MD English Translation by Dr. Susan Eslambolchi & Dr.

More information

Dual Force Cuspid Retractor

Dual Force Cuspid Retractor CLINICAL INNOVATION 1 Matrishva B Vyas, 2 Neeraj Alladwar ABSTRACT The most time consuming stage of bicuspid extraction-based treatment is cuspid retraction. Cuspid retraction with both types of conventional

More information

A finite element analysis of the effects of archwire size on orthodontic tooth movement in extraction space closure with miniscrew sliding mechanics

A finite element analysis of the effects of archwire size on orthodontic tooth movement in extraction space closure with miniscrew sliding mechanics Kawamura and Tamaya Progress in Orthodontics (2019) 20:3 https://doi.org/10.1186/s40510-018-0255-8 RESEARCH Open Access A finite element analysis of the effects of archwire size on orthodontic tooth movement

More information

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case Dhaval Ranjitbhai Lekhadia, Gautham Hegde RESEARCH ARTICLE 10.5005/jp-journals-10029-1149 A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

More information

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D. Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D. Abstract The ribbon arch previously had great popularity and utility early in the 20 th century, but lost its appeal as edgewise

More information

ORTHOdontics SLIDING MECHANICS

ORTHOdontics SLIDING MECHANICS ORTHOdontics PGI/II SLIDING MECHANICS FOCUS ON TARGETED SPACE GAINING AND ITS APPLICATIONS, INCLUDING WITH RAPID PALATAL EXPANDIONS. ALSO INCLUDES RETENTION AND CLINICAL PEARLS FACULTY: Joseph Ghafari,

More information

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Experience with Contemporary Tip-Edge plus Technique A Case Report. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 13, Issue 3 Ver. I. (Mar. 2014), PP 12-17 Experience with Contemporary Tip-Edge plus Technique A Case

More information

Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy

Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy Original Research 10.5005/jp-journals-10021-1237 Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy 1 Sreekrishnan B Nair, 2 AT

More information

The effect of Gable angle size and spring activation distance of 0.016x0.022 NiTi and TMA sectional T-loop towards force, moment y.

The effect of Gable angle size and spring activation distance of 0.016x0.022 NiTi and TMA sectional T-loop towards force, moment y. Padjadjaran Journal of Dentistry 2009;21(2):78-87. The effect of angle size and spring activation distance of 0.016x0.022 NiTi and TM sectional T-loop towards force, moment y values Norman Wachyudi, Tono

More information

INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS

INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS ORTHOdontics PGI PROBLEM SOLVING IN ORTHODONTICS INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS FACULTY: Fares

More information

With judicious treatment planning, the clinical

With judicious treatment planning, the clinical CLINICIAN S CORNER Selecting custom torque prescriptions for the straight-wire appliance Earl Johnson San Francisco, Calif Selecting custom torque prescriptions based on the treatment needs of each patient

More information

Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire

Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire European Journal of Orthodontics 26 (2004) 339 345 European Journal of Orthodontics vol. 26 no. 3 European Orthodontic Society 2004; all rights reserved. Three-dimensional finite element analysis in distal

More information

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required DEFINITION Fixed Appliances are devices or equipments that are attached to the teeth, cannot be removed by the patient and are capable of causing tooth movement. INDICATIONS Fixed Appliances are indicated

More information

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System. SM 3M Health Care Academy Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System. Dr. Gianluigi Fiorillo Dr. Gianluigi Fiorillo received

More information

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO 80302 Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS

More information

IJPCDR ORIGINAL RESEARCH ABSTRACT INTRODUCTION

IJPCDR ORIGINAL RESEARCH ABSTRACT INTRODUCTION ORIGINAL RESEARCH Comparison of the Conventional Method using Intraoral Periapical with the Contemporary Imaging Technology (Spiral Computed Tomography) for the Amount of Apical Root Resorption K. V. Sujan

More information

Measurements of the torque moment in various archwire bracket ligation combinations

Measurements of the torque moment in various archwire bracket ligation combinations European Journal of Orthodontics 34 (2012) 374 380 doi:10.1093/ejo/cjr022 Advance Access Publication 13 May 2011 The Author 2011. Published by Oxford University Press on behalf of the European Orthodontic

More information

Holy Nexus of Variable Wire Cross-section: New Vistas in Begg s Technique

Holy Nexus of Variable Wire Cross-section: New Vistas in Begg s Technique 10.5005/jp-journals-10021-1012 ORIGINAL ARTICLE Holy Nexus of Variable Wire Cross-section: New Vistas in Begg s Technique 1 Anil Miglani, 2 Ranjit Kumar Reena, 3 Pawanjit Singh Walia, 4 Varun Grover ABSTRACT

More information

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Fabio Schemann-Miguel 1, Flávio Cotrim-Ferreira 2, Alessandra Motta Streva 3, Alexander Viégas de

More information

2007 JCO, Inc. May not be distributed without permission.

2007 JCO, Inc. May not be distributed without permission. 2007 JCO, Inc. May not be distributed without permission. www.jco-online.com CSE REPORT Correction of an symmetrical Class II Malocclusion Using Predictable Force Systems PIERO PLCIOS, DDS, MDS FLVIO URIBE,

More information

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports Case Report Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports Helen Taylor, BDS, MScD, DOrth, MOrth, FDSRCS(Eng) a Abstract: Vertical control is

More information

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT Authors: Dr Arun Kumar G a Master of Dental Surgery(Orthodontics) Associate Professor, Department of Orthodontics & Dentofacial

More information

Gentle-Jumper- Non-compliance Class II corrector

Gentle-Jumper- Non-compliance Class II corrector 15 CASE REPORT Gentle-Jumper- Non-compliance Class II corrector Amit Prakash 1,O.P.Mehta 2, Kshitij Gupta 3 Swapnil Pandey 4 Deep Kumar Suryawanshi 4 1 Senior lecturer Bhopal - INDIA 2 Professor Bhopal

More information

Measurement of Forces and Moments in Three- Dimensional Archwires

Measurement of Forces and Moments in Three- Dimensional Archwires Virginia Commonwealth University VCU Scholars Compass Theses and Dissertations Graduate School 2003 Measurement of Forces and Moments in Three- Dimensional Archwires Dwight Van Buelow Virginia Commonwealth

More information

6. Timing for orthodontic force

6. Timing for orthodontic force 6. Timing for orthodontic force Orthodontic force is generally less than 300gm, so early mechanical stability is enough for immediate orthodontic force. There is no actually difference in success rate

More information

Comparison of Rate of Canine Retraction into Recent Extraction Site with and without Gingival Fiberotomy: A Clinical Study

Comparison of Rate of Canine Retraction into Recent Extraction Site with and without Gingival Fiberotomy: A Clinical Study JCDP 10.5005/jp-journals-10024-1338 Comparison of Rate of Canine Retraction into Recent Extraction Site with and without Gingival Fiberotomy ORIGINAL RESEARCH Comparison of Rate of Canine Retraction into

More information

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain Welcome Ron Not Ron? Click here. My Account The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain VOLUME 26 : NUMBER 03 : PAGES (165-178) 1992 CHRISTOPHER K. KESLING, DDS, MS Tooth movement in

More information

The management of impacted

The management of impacted Using a rigid hook and spring auxiliary slid onto the archwire to direct eruption of impacted teeth BY S. JAY BOWMAN, DMD, MSD, AND ALDO CARANO, DR ODONT, MS, SPEC ORTHOD Figure 1: A 12-year-old female

More information

There had been controversies concerning how to achieve maximum anchorage in the first premolar extraction cases.

There had been controversies concerning how to achieve maximum anchorage in the first premolar extraction cases. Cronicon OPEN ACCESS EC DENTAL SCIENCE Research Article Comparison Between the Stresses Induced on Vital Structures During Two Steps and En-Masse Retraction Methods of Upper Anterior Segment Depending

More information

Full-step Class II extraction patients, patients

Full-step Class II extraction patients, patients ORIGINAL ARTICLE Group A T-loop for differential moment mechanics: An implant study Renato Parsekian Martins, a Peter H. Buschang, b and Luiz Gonzaga Gandini Jr c Araraquara, Brazil, and Dallas, Tex Introduction:

More information

Biomechanics in Orthodontics: Principles and Practice

Biomechanics in Orthodontics: Principles and Practice Biomechanics in Orthodontics: Principles and Practice Biomechanics IN Orthodontics PRINCIPLES AND PRACTICE Ram S. Nanda, BDS, DDS, MS, PhD Professor Emeritus Department of Orthodontics College of Dentistry

More information

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System The Loading And Unloading roperties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System Authors: Thomas Mathew MDS Orthodontics, Lecturer, Faculty of Dentistry,

More information

The Tip-Edge appliance and

The Tip-Edge appliance and Figure 1: Internal surfaces of the edgewise archwire slot are modified to create the Tip-Edge archwire slot. Tipping surfaces (T) limit crown tipping during retraction. Uprighting surfaces (U) control

More information

Prediction of optimal bending angles of a running loop to achieve bodily protraction of a molar using the finite element method

Prediction of optimal bending angles of a running loop to achieve bodily protraction of a molar using the finite element method Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-718 eissn 200-372X https://doi.org/10.4041/kjod.2018.48.1.3 Prediction of optimal bending angles of a running loop to achieve bodily protraction

More information

A SIMPLE METHOD FOR CORRECTION OF BUCCAL CROSSBITE OF MAXILLARY SECOND MOLAR

A SIMPLE METHOD FOR CORRECTION OF BUCCAL CROSSBITE OF MAXILLARY SECOND MOLAR Short Communication International Journal of Dental and Health Sciences Volume 01,Issue 03 A SIMPLE METHOD FOR CORRECTION OF BUCCAL CROSSBITE OF MAXILLARY SECOND MOLAR Sumit Yadav 1,Davender Kumar 2,Achla

More information

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS. TURN CLASS II INTO SIMPLE CLASS I PATIENTS. THE CARRIERE MOTION TM APPLIANCE fast gentle natural The Carriere Philosophy. Fast. Shortens overall treatment time by up to four months as it treats Class II

More information

Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis

Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis ORIGINAL ARTICLE Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis Sang-Jin Sung, a Gang-Won Jang, b Youn-Sic Chun, c and Yoon-Shik Moon d Seoul and

More information

Space Closure Biomechanics Applied Using The MBT System Technique

Space Closure Biomechanics Applied Using The MBT System Technique Space Closure Biomechanics Applied Using The MBT System Technique by Hugo Trevisi, D.D.S. Dr. Hugo Trevisi, São Paulo, Brazil Dr. Hugo Trevisi received his dental degree in 1974 at Lins College of Dentistry

More information

Testing Force Systems and Biomechanics Measured Tooth Movements from Differential Moment Closing Loops

Testing Force Systems and Biomechanics Measured Tooth Movements from Differential Moment Closing Loops Original Article Testing Force Systems and Biomechanics Measured Tooth Movements from Differential Moment Closing Loops Andrew J. Kuhlberg, DMD, MDS a ; Derek Priebe, DDS, MDS b Abstract: Orthodontic tooth

More information

Treatment of a malocclusion characterized

Treatment of a malocclusion characterized CONTINUING EDUCATION ARTICLE Cephalometric evaluation of open bite treatment with NiTi arch wires and anterior elastics Nazan Küçükkeleș, DDS, PhD, a Ahu Acar, DDS, PhD, b Arzu A. Demirkaya, DDS, c Berna

More information

Case Report Unilateral Molar Distalization: A Nonextraction Therapy

Case Report Unilateral Molar Distalization: A Nonextraction Therapy Case Reports in Dentistry Volume 2012, Article ID 846319, 4 pages doi:10.1155/2012/846319 Case Report Unilateral Molar Distalization: A Nonextraction Therapy M. Bhanu Prasad and S. Sreevalli Department

More information

Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics

Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics Dr MJ Rowland-Warmann BSc BDS (Manc) MSc Aes.Med. (Lond) MJDF RCS (Eng) GDC: 178642

More information

REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO Dr. Nanda Dr. Marzban Dr. Kuhlberg

REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO Dr. Nanda Dr. Marzban Dr. Kuhlberg REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO 80302 Dr. Nanda Dr. Marzban Dr. Kuhlberg Dr. Nanda is Professor, Head, and Program Director, Dr. Marzban is a thirdyear

More information

An Effectiv Rapid Molar Derotation: Keles K

An Effectiv Rapid Molar Derotation: Keles K An Effectiv ective e and Precise Method forf Rapid Molar Derotation: Keles K TPA Ahmet Keles, DDS, DMSc 1 /Sedef Impar, DDS 2 Most of the time, Class II molar relationships occur due to the mesiopalatal

More information

UNILATERAL UPPER MOLAR DISTALIZATION IN A SEVERE CASE OF CLASS II MALOCCLUSION. CASE PRESENTATION. 1*

UNILATERAL UPPER MOLAR DISTALIZATION IN A SEVERE CASE OF CLASS II MALOCCLUSION. CASE PRESENTATION. 1* UNILATERAL UPPER MOLAR DISTALIZATION IN A SEVERE CASE OF CLASS II MALOCCLUSION. CASE PRESENTATION. 1* Department of Orthodontics and Pedodontics 1 Faculty of Dental Medicine, University of Medicine and

More information

Initial Displacement of Teeth as an Indicator of Ideal Force System for En Masse Retraction Using Mini Implant A FEM Study

Initial Displacement of Teeth as an Indicator of Ideal Force System for En Masse Retraction Using Mini Implant A FEM Study Original Article Initial Displacement of Teeth as an Indicator of Ideal Force System for En Masse Retraction Using Mini Implant A FEM Study 1 Laljit Singh Brar, 2 Suresh Babu, 3 Ashutosh Wadhawan To cite:

More information

MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D

MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D Dr. Masatada Koga, D.D.S., Ph.D, is an assistant professor in the Department of Orthodontics

More information

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment?

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment? TURKISH JOURNAL of DOI: 10.5152/TurkJOrthod.2017.17034 CASE REPORT Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction

More information

An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case

An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case 10.5005/jp-journals-10021-1127 CASE REPORT An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case 1 Anil Miglani, 2 Reena R Kumar, 3 Ashish Chopra,

More information

Case Report Orthodontic Replacement of Lost Permanent Molar with Neighbor Molar: A Six-Year Follow-Up

Case Report Orthodontic Replacement of Lost Permanent Molar with Neighbor Molar: A Six-Year Follow-Up Hindawi Case Reports in Dentistry Volume 2017, Article ID 4206435, 9 pages https://doi.org/10.1155/2017/4206435 Case Report Orthodontic Replacement of Lost Permanent Molar with Neighbor Molar: A Six-Year

More information

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

Canine Extrusion Technique with SmartClip Self-Ligating Brackets Canine Extrusion Technique with SmartClip Self-Ligating Brackets Dr. Luis Huanca Ghislanzoni Dr. Luis Huanca received his DDS in 2006 and the MS and Specialist in Orthodontics in 2009 from the University

More information

3M Incognito Appliance System extraction case study.

3M Incognito Appliance System extraction case study. SM 3M Health Care Academy 3M Incognito Appliance System extraction case study. Toru Inami, DDS, Ph.D. Dr. Toru Inami graduated from the Aichigakuin University School of Dentistry in 1976. From 1977 to

More information

Nonsurgical Treatment of Adult Open Bite Using Edgewise Appliance Combined with High-Pull Headgear and Class III Elastics

Nonsurgical Treatment of Adult Open Bite Using Edgewise Appliance Combined with High-Pull Headgear and Class III Elastics Case Report Nonsurgical Treatment of Adult Open Bite Using Edgewise Appliance Combined with High-Pull Headgear and Class III Elastics Isao Saito, DDS, PhD a ; Masaki Yamaki, DDS, PhD b ; Kooji Hanada,

More information

Orthodontic treatment of midline diastema related to abnormal frenum attachment - A case series.

Orthodontic treatment of midline diastema related to abnormal frenum attachment - A case series. Orthodontic treatment of midline diastema related to abnormal frenum attachment - A case series. Running title: Orthodontic treatment of midline diastema. Dr. Amit Dahiya 1, Dr. Minakshi Rana 2, Dr. Arun

More information

Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews.

Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews. SM 3M Health Care Academy Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews. Dr. J.C. Pérez-Varela MD, DDS, MS, Ph.D. Specialist in Orthodontics. Doctor of Medicine

More information

Crowded Class II Division 2 Malocclusion

Crowded Class II Division 2 Malocclusion Class II Division 2 Malocclusion Crowded Class II Division 2 Malocclusion Clinicians: Drs. Chris Chang, Hsin-Yin Yeh, Sophia Pei-Wen Shu, W. Eugene Roberts Patient: Miss Jhan Pre-treatment Diagnosis An

More information

Mechanical evaluation of space closure loops in Orthodontics

Mechanical evaluation of space closure loops in Orthodontics Orthodontics Orthodontics Mechanical evaluation of space closure loops in Orthodontics Eduardo Uggeri Rodrigues (a) Hiroshi Maruo (a) Odilon Guariza Filho (a) Orlando Tanaka (a) Elisa Souza Camargo (a)

More information

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases by Lisa Alvetro, DDS, MSD After receiving her DDS summa cum laude from Ohio State University, Dr. Alvetro

More information

AlignEUSummit2015_PPT Template- GEN SESSION_

AlignEUSummit2015_PPT Template- GEN SESSION_ Innovations of Invisalign Clear Aligners John Morton Director of Research and Technology 1 2016 Align Technology, Inc. All rights reserved. Legal Disclaimer The statements, views and opinions expressed

More information

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

Finite Element Analysis of Dental Implant as Orthodontic Anchorage JCDP 10.5005/jp-journals-10024-1044 ORIGINAL RESEARCH Finite Element Analysis of Dental Implant as Orthodontic Anchorage Finite Element Analysis of Dental Implant as Orthodontic Anchorage Anirban Sarmah,

More information

Study Model-based Evaluation of Built-in Tip, Torque, and In out Characteristics of a Third-generation Preadjusted Edgewise Appliance

Study Model-based Evaluation of Built-in Tip, Torque, and In out Characteristics of a Third-generation Preadjusted Edgewise Appliance Rishabh Gupta et al ORIGINAL RESEARCH 10.5005/jp-journals-10024-2206 Study Model-based Evaluation of Built-in Tip, Torque, and In out Characteristics of a Third-generation Preadjusted Edgewise Appliance

More information

Orthodontic Treatment Using The Dental VTO And MBT System

Orthodontic Treatment Using The Dental VTO And MBT System Orthodontic Treatment Using The Dental VTO And MBT System by Dr. Hideyuki Iyano Dr. Hideyuki Iyano, Department of Orthodontics, Ohu University School of Dentistry, Japan. He is also a member of the Japan

More information

Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek

Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek Dr. Wiezorek studied dental medicine at Kiel University, Germany from 1987 to 1993. He then finished

More information

Miniscrew-supported coil spring for molar uprighting: Description

Miniscrew-supported coil spring for molar uprighting: Description Miniscrew-supported coil spring for molar uprighting: Description ntônio Carlos de Oliveira Ruellas 1, Matheus Melo Pithon 2, Rogério Lacerda dos Santos 3 Introduction: Since the beginning of miniscrews

More information

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment by Lisa Alvetro, DDS After receiving her DDS summa cum laude from Ohio State University, Dr. Lisa Alvetro completed

More information

Ortho-surgical Management of Severe Vertical Dysplasia: A Case Report

Ortho-surgical Management of Severe Vertical Dysplasia: A Case Report Case Report Ortho-surgical Management of Severe Vertical Dysplasia: A Case Report 1 Vinni Arora, 2 Rekha Sharma, 3 Sachin Parashar 1 Senior Resident, 2 Professor and Head of Department, 3 Former Resident

More information

A finite element simulation of initial movement, orthodontic movement, and the centre of resistance of the maxillary teeth connected with an archwire

A finite element simulation of initial movement, orthodontic movement, and the centre of resistance of the maxillary teeth connected with an archwire European Journal of Orthodontics 36 1 of (2014) 7 255 261 The Author 2011. Published by Oxford University Press on behalf of the European Orthodontic Society. doi:10.1093/ejo/cjr123 All rights reserved.

More information

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS. TURN CLASS II INTO SIMPLE CLASS I PATIENTS. THE CARRIERE MOTION TM APPLIANCE fast gentle natural The Carriere Philosophy. Fast. Shortens overall treatment time by up to four months as it treats Class II

More information

A New Low-Friction Ligation System

A New Low-Friction Ligation System 2005 JCO, Inc. May not be distributed without permission. www.jco-online.com A New Low-Friction Ligation System ARTURO FORTINI, MD, DDS MASSIMO LUPOLI, MD, DDS VITTORIO CACCIAFESTA, DDS, MS Many factors

More information

In biocreative therapy (C-therapy), torque control

In biocreative therapy (C-therapy), torque control ONLINE ONLY Factors controlling anterior torque with C-implants depend on en-masse retraction without posterior appliances: Biocreative therapy type II technique Sung-Seo Mo, a Seong-Hun Kim, b Sang-Jin

More information

Correction of Class II Division 2 Malocclusion by Fixed Functional Class II Corrector Appliance: Case Report

Correction of Class II Division 2 Malocclusion by Fixed Functional Class II Corrector Appliance: Case Report Case Report To cite: Kumar M, Sharma H, Bohara P. Correction of class II division 2 malocclusion by fixed functional class II corrector appliance: case report. Journal of contemporary orthodontics, February

More information

AL-AZHAR. Dental Journal. Print ISSN Online ISSN ADJ-for Girls, Vol. 5, No. 1, January (2018) PP. 9:14

AL-AZHAR. Dental Journal. Print ISSN Online ISSN ADJ-for Girls, Vol. 5, No. 1, January (2018) PP. 9:14 AL-AZHAR Dental Journal F o r G i r l s The Official Publication of The Faculty of Dental Medicine For Girls, Al-Azhar University Cairo, Egypt. Print ISSN 2537-0308 Online ISSN 2537-0316 ADJ-for Girls,

More information

Different Non Surgical Treatment Modalities for Class III Malocclusion

Different Non Surgical Treatment Modalities for Class III Malocclusion IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 6 (Sep.- Oct. 2013), PP 48-52 Different Non Surgical Treatment Modalities for Class III Malocclusion

More information

Orthodontic treatment for jaw defor. Sakamoto, T; Sakamoto, S; Harazaki, Author(s) Yamaguchi, H. Journal Bulletin of Tokyo Dental College, 4

Orthodontic treatment for jaw defor. Sakamoto, T; Sakamoto, S; Harazaki, Author(s) Yamaguchi, H. Journal Bulletin of Tokyo Dental College, 4 Orthodontic treatment for jaw defor Titlelip and palate patients with the co external-expansion arch and a facia Sakamoto, T; Sakamoto, S; Harazaki, uthor(s) Yamaguchi, H Journal ulletin of Tokyo Dental

More information

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 3 (Jul.- Aug. 2013), PP 47-51 Is nickel titanium superior to multistranded stainless steel

More information

AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015

AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015 AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015 Title: Clinical and iomechanical Considerations of TADs in Challenging Cases: Sagittal Correction beyond Orthodontic oundaries

More information

Effective Tooth Movement Using Lingual Segmented Arch Mechanics Combined With Miniscrews

Effective Tooth Movement Using Lingual Segmented Arch Mechanics Combined With Miniscrews 日本舌側矯正歯科学会会誌 23 原 著 Effective Tooth Movement Using Lingual Segmented Arch Mechanics Combined With Miniscrews Tae-Hyun Choi a) Kyung-Keun Shi b), Young-Chel Park c), Kee-Joon Lee d) Department of Orthodontics,

More information

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi A Clinical Review of the MBT Versatile+ Appliance System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi Treatment Philosophy of the MBT Appliance System

More information

ABSTRACT INTRODUCTION /jp-journals

ABSTRACT INTRODUCTION /jp-journals ORIGINAL RESEARCH 10.5005/jp-journals-10024-2102 An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions

More information

Case Report. profile relaxed relaxed smiling. How would you treat this malocclusion?

Case Report. profile relaxed relaxed smiling. How would you treat this malocclusion? Pre-Treatment profile relaxed relaxed smiling How would you treat this malocclusion? Case R. C. 16 years, 9 months introduction This female adolescent with bilabial protrusion and flared upper anterior

More information

Intraoral molar-distalization appliances that

Intraoral molar-distalization appliances that 2014 JCO, Inc. May not be distributed without permission. www.jco-online.com Distalization with the Miniscrew- Supported EZ Slider Auxiliary ENIS GÜRAY, DDS, PHD FARUK IZZET UCAR, DDS, PHD NISA GUL, DDS

More information

Angle s Molar Classification Revisited

Angle s Molar Classification Revisited Devanshi Yadav et al Original Article 10.5005/jp-journals-10021-1282 Angle s Molar Classification Revisited 1 Devanshi Yadav, 2 MS Rani, 3 AM Shailaja, 4 Dhruv Anand, 5 Nikhil Sood, 6 Rajat Gothi ABSTRACT

More information

Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case

Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case Hayder A. Hashim, BDS, MSc Abstract Aim: The purpose of this article is to show the value of serial extractions in a

More information

Response of the maxillary dentition to a statically determinate one-couple system with tip-back mechanics: A prospective clinical trial

Response of the maxillary dentition to a statically determinate one-couple system with tip-back mechanics: A prospective clinical trial Original Article Response of the maxillary dentition to a statically determinate one-couple system with tip-back mechanics: A prospective clinical trial Nandakumar Janakiraman a ; Pawandeep Gill b ; Madhur

More information

Longitudinal Measurements of Tooth Mobility during Orthodontic Treatment Using a Periotest

Longitudinal Measurements of Tooth Mobility during Orthodontic Treatment Using a Periotest Original Article Longitudinal Measurements of Tooth Mobility during Orthodontic Treatment Using a Periotest Eiji Tanaka, DDS, PhD a ; Kazuhiro Ueki, DDS, PhD b ; Mayu Kikuzaki, DDS c ; Eitaro Yamada, DDS

More information

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires S1:1 170421 7390 SOLITAIRE Single Pack s OrthoQuest offers the highest quality wires available in the orthodontic industry. Our wires are designed to exact specifications by trained engineers and manufactured

More information

THE MBT VERSATILE+ APPLIANCE SYSTEM

THE MBT VERSATILE+ APPLIANCE SYSTEM THE MBT VERSATILE+ APPLIANCE SYSTEM McLaughlin, Bennett, Trevisi The MBT Versatile+ Appliance System THE DEVELOPMENT OF A TREATMENT MECHANICS AND APPLIANCE PHILOSOPHY The first fully programmed preadjusted

More information

MemRx Orthodontic Appliances

MemRx Orthodontic Appliances MemRx Orthodontic Appliances Uses and Instructions The MemRx Fundamentals As the need for faster, more efficient treatment of non-compliant patients increases, orthodontic!technology and materials has

More information

TADs Supported Tongue Crib: A New Minimalistic Design

TADs Supported Tongue Crib: A New Minimalistic Design Clinical Pearl TADs Supported Tongue Crib: A New Minimalistic Design Patni V 1, Kolge NE 2 To cite: Patni V, Kolge NE. TADs Supported Tongue Crib: A New Minimalistic Design. Journal of Contemporary Orthodontics,

More information

Orthodontic bracket slot dimensions as measured from entire bracket series

Orthodontic bracket slot dimensions as measured from entire bracket series Original Article Orthodontic bracket slot dimensions as measured from entire bracket series Paul Brown a ; Warren Wagner b ; Hyden Choi c ABSTRACT Objective: To measure the slot dimensions of an entire

More information

1. Muhammad Moazzam 2. Waheed-ul-Hameed 3. Rana Modassir Shamsher Khan 4. Abdul Samad Khan 5. Imran Rahber 6. Muhammad Osman Masood

1. Muhammad Moazzam 2. Waheed-ul-Hameed 3. Rana Modassir Shamsher Khan 4. Abdul Samad Khan 5. Imran Rahber 6. Muhammad Osman Masood Single Arch Treatment in Class II Div 1 Malocclusion {Original Article (Dentistry)} 1. Muhammad Moazzam 2. Waheed-ul-Hameed 3. Rana Modassir Shamsher Khan 4. Abdul Samad Khan 5. Imran Rahber 6. Muhammad

More information

2008 JCO, Inc. May not be distributed without permission. Correction of Asymmetry with a Mandibular Propulsion Appliance

2008 JCO, Inc. May not be distributed without permission.   Correction of Asymmetry with a Mandibular Propulsion Appliance 2008 JCO, Inc. May not be distributed without permission. www.jco-online.com CASE REPORT Correction of Asymmetry with a Mandibular Propulsion Appliance JOSÉ AUGUSTO MENDES MIGUEL, DDS, MSC, PHD GUSTAVO

More information

An estimated 25-30% of all orthodontic patients can benefit from maxillary

An estimated 25-30% of all orthodontic patients can benefit from maxillary 2017 JCO, Inc. May not be distributed without permission. www.jco-online.com A New Appliance for Efficient Molar Distalization VAIBHAV GANDHI, BDS, MDS FALGUNI MEHTA, BDS, MDS HARSHIK PAREKH, BDS, MDS

More information

TWO PHASE FOR A BETTER FACE!! TWIN BLOCK AND HEADGEAR FOLLOWED BY FIXED THERAPY FOR CLASS II CORRECTION

TWO PHASE FOR A BETTER FACE!! TWIN BLOCK AND HEADGEAR FOLLOWED BY FIXED THERAPY FOR CLASS II CORRECTION Case Report NUJHS Vol. 5, No.2, June 2015, ISSN 2249-7110 TWO PHASE FOR A BETTER FACE!! TWIN BLOCK AND HEADGEAR FOLLOWED BY FIXED THERAPY FOR CLASS II CORRECTION 1 2 3 4 U S Krishna Nayak, Ashutosh Shetty,

More information

Plastic deformation occurs if the stress exceeds the

Plastic deformation occurs if the stress exceeds the ONLINE ONLY Effects of stress relaxation in beta-titanium orthodontic loops Sergei Godeiro Fernandes Rabelo Caldas, a Renato Parsekian Martins, b Rodrigo F. Viecilli, c Marılia Regalado Galv~ao, a and

More information

Mesial Step Class I or Class III Dependent upon extent of step seen clinically and patient s growth pattern Refer for early evaluation (by 8 years)

Mesial Step Class I or Class III Dependent upon extent of step seen clinically and patient s growth pattern Refer for early evaluation (by 8 years) Orthodontics and Dentofacial Development Overview Development of Dentition Treatment Retention and Relapse Growth of Naso-Maxillary Complex Develops postnatally entirely by intramenbranous ossification

More information

Segmental Orthodontics for the Correction of Cross Bites

Segmental Orthodontics for the Correction of Cross Bites 10.5005/jp-journals-10005-1080 CASE REPORT IJCPD Segmental Orthodontics for the Correction of Cross Bites 1 Anirudh Agarwal, 2 Rinku Mathur 1 Professor and Head, Department of Orthodontics, Rajasthan Dental

More information

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY THE EFFECTIVENESS OF SURESMILE TECHNOLOGY TO ACHIEVE PREDICTED TREATMENT OUTCOME A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY CHRISTOPHER JOHN VAUBEL IN PARTIAL

More information

Management of Congenitally Missing Lateral Incisor

Management of Congenitally Missing Lateral Incisor 10.5005/jp-journals-10021-1016 CASE REPORT JIOS Management of Congenitally Missing Lateral Incisor 1 Nidhi Kedia, 2 Ashima Valiathan ABSTRACT Multiple treatment options are available to patients who have

More information