Technical Specification

Size: px
Start display at page:

Download "Technical Specification"

Transcription

1 SPECIFICATION Technical Specification Product Name Meter Type Blood Sample Blood Volume Test Strip Type Measuring Range Measuring Time Power Battery Life Memory Capacity Operating Temp. Operating Humidity Storage Temperature Dimensions Weight Healthy Line Blood Glucose Meter SHL-G800 Fresh capillary whole blood 0.5 ul SHL-GS50, SHL-GS mmol/l 5 seconds One 3V Lithium Battery type (CR2032) Approximately 1000 tests 300 test results (include time and date) 10 ~ 40 10% ~ 90 % 4 ~ mm x 54 mm x 86 mm 45g (with battery) TM ealthy ine Va multumim ca ati ales un produs din gama swisshealthcorporation, ati facut o alegere inspirata. TM Produsele ealthy ine swisshealthcorporation sunt create special pentru dumneavoastra, avand ca principal scop, dorinta de a va oferi prin intermediul tehnologiilor de inalta calitate, SOLUTII PENTRU O SANATATE PERFECTA Sistem digital de monitorizare a glucozei in sange Model SHL-G800 TM ealthy ine swiss health corporation ROMANA 1

2 ATENTIONARI Atentionari Folosire si pastrare Aparatul este destinat pentru a fi folosit acasa Inaintea utilizarii, aparatul trebuie lasat sa se aclimatizeze cu temperatura mediului ambiant aproximativ 20 minute. Pentru a obtine masuratori exacte, nu permiteti prafului si al altor corpuri straine sa patrunda in fanta de introducere a benzii de testare Nu incercati sa desfaceti, sa reparati si/sau sa aduceti modificari aparatului. Nu asezati aparatul langa alte aparate care emit unde electromagnetice ( ex. televizoare, aparate cu microunde, telefoane mobile ). Nu bruscati si nu loviti aparatului in timpul folosirii. Pentru curatarea aparatului nu folositi solutii acide sau diluanti (ex.acetona), este recomandata utilizarea unei carpe de bumbac usor umezita. Aveti grija ca testele sa fie utilizate numai in termenul de valabilitate. Nu refolositi testele. Utilizarea acestui produs nu este recomandat femeilor gravide, copiilor nou nascuti sau persoanelor care au o deshidratare accentuata. Aparatul SHL-G800 utilizeaza numai teste modelul SHL-GS50 () Informatii de siguranta Inaintea utilizarii produsului, cititi cu atentie manualul de utilizare. Nu pastrati aparatul si celelalte accesorii ale acestuia in locuri unde copilul poate ajunge cu usurinta. Dezinfectati si stergeti aparatul de petele de sange aparute. Nu reutilizati benzile de teste. Acordati mare atentie la manuirea testelor si lansatorului de ace. Intregul aparat este folosit numai pentru uz extern. ATENTIONARI Atentionari asupra benzilor de test (strip) Continut produs SHL-G800 Benzile de test sunt sensibile la umiditate, de aceea recipientul in care se gasesc testele trebuie sa aiba in permanenta capacul inchis. Nu permiteti ca benzile de test sa stea foarte mult timp in afara recipientului. Scoaterea testului din recipient se face cu mana curata si uscata. Validitatea testelor este de 18 luni pastrate sub sigiliu si de 3 luni dupa deschiderea recipientului. Glucometru Geanta transport Lansator ace Ace Cutie teste Manualul utilizatorului

3 CONTINUT 50 Descrierea glucometrului SHL-G800 Afisaj Butonul 'M' Fanta de introducere a benzii de testare FATA Butonul 'C' SPATE Eticheta Capac baterie Prepararea testului Deschideti capacul si apoi scoateti un test Inainte de a face testul propriuzis, verificat codul de pe sticluta cu codul ce va apare pe afisaj in momentul introducerii testului in dispozitiv Tick! 2.Inchideti imediat capacul dupa scoaterea testului CONTINUT Descrierea recipient de teste SHL-GS50() Sticluta benzilor de test 50 LOT numar LOT Valabilitate Healthy Line SHL-GSXX Capilar colectare sange Introducerea testului in aparat Beep! Testele SHL-GS50() se folosesc numai la aparatul SHL-G800. Notati data deschiderii unei sticlute de test pentru a evita utilizarea acestora dupa expirare. Verificati validitatea testelor inainte de utilizare. Cititi cu atentie manualul, mai ales in cea ce priveste testele Introduceti testul in aparat in locul indicat in imaginea de mai sus, iar in scurt timp veti auzi un bip si pe ecran va apare un cod. Verificarea codului Verificati daca codul aparut pe ecran este acelasi cu cel de pe sticluta. Daca codul de pe ecran nu corespunde cu cel de pe sticluta va trebui efectuata setarea corecta a codului in aparat. 4 5

4 PREGATIRE Ajustarea codului 50 Aparatul permite setarea codurilor de la 01 la 70, setarea din fabrica va avea codul. Ajustarea codului se face cu autorul butoanelor M sau C. Apasand pe butonul M acesta va incrementa cate o unitate, apasand pe butonul C acesta va decrementa cate o unitate. Tinand apasat mai mult timp pe butonul M sau C se va incrementa sau decrementa mai repede. In momentul introducerii testului in aparat acesta va afisa scurt timp pe ecran toate simbolurile, dupa care va indica pentru 3 secunde codul existent in memorie. In momentul in care pe afisaj apare codul, se pot face ajustarile astfel incat codul de pe sticluta sa corespunda cu ce este afisat. In momentul in care codul de pe afisaj corespunde cu cel de pe sticluta nu se mai apasa pe nimic. Asteptati 3 secunde si aparatul va trece in modul de asteptare a picaturii de sange. Codul, odata setat in aparat va fi memorat, aceasta procedura trebuie refacuta doar daca un nou recipient cu teste are alt cod sau daca este necesara inlocuirea bateriei. Simbolul, asteptarea picaturii de sange Dupa alegerea corecta a codului, la un interval de 3 secunde, pe afisaj va apare simbolul, incepand din acest moment aparatul este pregatit pentru masurarea glicemiei, asteptand picatura de sange pe banda de test. Metode de testare Dezinfectare Inainte de a se face testul de glicemie, spalati-va pe maini cu apa calda si sapun, apoi stergeti-va bine, astfel incat mainile sa fie uscate. Puteti sa dezinfectati degetul din care veti lua picatura de sange cu o carpa curata de bumbac inmuiata in alcool, apoi asteptati evaporarea alcoolului de pe deget Cum colectam picatura de sange 1. Desurubati capul lansetei in sensul invers acelor de ceasornic 2. In timp ce tineti partea inferioara a lansetei luati un ac steril si il introduceti in aceasta 3. Rasuciti capul de plastic ce protejeaza varful acului si desprindeti-l, astfel ca acesta sa ramana liber PREGATIRE

5 PREGATIRE Puneti la loc partea superioara a lansetei, prin infiletare in sensul acelor de ceasornic. 5. Tineti ferm cu o mana partea superioara a lansetei si trageti cu cealalta mana de partea glisanta care se afla in capatul celalalt al lansetei. Acum lanseta s-a incarcat si va permite prin apasarea butonului de pe lanseta sa faca intepatura. 6. Asezati degetul din care doriti sa luati sange in varful lansetei si apasati pe butonul de pe lanseta. Adaugarea picaturii de sange Atingeti la baza picaturii de sange cu capatul testului care a ramas in afara aparatului. Picatura de sange va fi absorbita, prin canalul benzii de test, pana la umplerea acestuia, pe ecran va incepe numerotarea inversa incepand cu cifra 5. Capatul benzii de test trebuie asezata la baza picaturii de sange. Nu picurati sange direct pe banda de test. PREGATIRE 7 7. Strangeti si masati usor degetul pana va apare o picatura de sange pe varful degetului. NU stoarceti cu putere. Procesul de testare Asteptati 5 secunde, dupa trecerea aceastora veti auzi un bip iar pe ecran va aparea rezultatul masurarii glicemiei cu data si ora. Nu scuturati aparatul in timpul masuratorii. 8 Nu folositi un ac care a mai fost utilizat de altcineva. Nu lasati acul in lanseta dupa utilizare. Nu reutilizati acul. Acul folosit se arunca in locuri speciale. Pastrati acele si lanseta in locuri in care copiii sa nu aiba cces. Dupa afisarea rezultatului, scoateti banda de test din aparat. Dupa scoaterea benzii de test din aparat acesta se va inchide automat. Daca rezultatul testului este anormal, folositi o noua banda de test. 9

6 PREGATIRE. Utilizarea memoriei si setarile aparatului Verificarea rezultatelor din memoria aparatului In acest moment, daca apasati in mod repetat butonul C, pe ecran vor fi afisate pe rand rezultatele ultimelor masuratori memorate de aparat. PREGATIRE BEEP! 1.Incepeti cu aparatul inchis. Apasati pe butonul M, veti auzi un bip si aparatul este astfel pornit. 2. Imediat dup pornire pe ecran vor fi afisate data si ora DAY AVG 3. Dupa 2 secunde, apartul va afisa automat media rezultatelor obtinute din masuratorile ultimele 14 zile. 4. Apasati o data pe butonul C si rezultatul celei mai recente masuratori va fi afisat impreuna cu informatiile despre data si ora Dupa verificarea completa a rezultatelor din memorie, puteti parasi operatiunea prin apasarea butonului M, astfel aparatul se va inchide. Tinand apasat pe butonul C viteza derularii rezultatelor va fi accelerata. Daca nu se inchide aparatul apasand pe butonul M, acesta se va inchide automat in 10 min

7 PREGATIRE Setarea Datei si Orei Incepeti cu aparatul inchis. Tineti apasat circa 3 secunde pe butonul M, se va auzi un bip iar pe ecran vor fi afisate toate simbolurile. Dupa o secunda ecranul va trece in modul de setare. Secventele modificarii datei si a orei Setare luna BEEP! Setare zi Setare format ora Setare ora Setare minut Setare an Setarea lunii Cand cifra care simbolizeaza luna clipeste, apasati pe butonul C de cate ori este nevoie pana cand va aparea cifra corespunzatoare lunii dorite. Apoi apasati o data pe butonul M pentru mutarea setarii pe o alta cifra care va clipi. Setarea zilei Cand cifra care simbolizeaza ziua clipeste, apasati pe butonul C de cate ori este nevoie pana cand va aparea cifra corespunzatoare zilei dorite. Apoi apasati o data pe butonul M pentru mutarea setarii pe o alta cifra care va clipi. Setarea formatului orei Aparatul poate fi setat intr-unul dintre formatele de afisare: 12 ore sau 24 de ore. Apasati pe butonul 'C' ca sa apara formatul dorit si apoi apasati pe butonul 'M' pentru mutarea setarii. PREGATIRE 12 13

8 PREGATIRE Setarea orei Cand cifra care simbolizeaza ora clipeste, apasati pe butonul C de cate ori este nevoie pana cand va aparea cifra orei dorite. Apoi apasati o data pe butonul M pentru mutarea setarii pe o alta cifra care va clipi. Stergera rezultatelor PREGATIRE BEEP! Setarea minutului Cand cifra care simbolizeaza minutul clipeste, apasati pe butonul C de cate ori este nevoie pana cand va aparea cifra minutului dorit. Apoi apasati o data pe butonul M pentru mutarea setarii pe o alta cifra care va clipi. Setarea anului Setarea anului se face de la cifra 08 la 20 (adica intre 2008 si 2020). Cand cifra care simbolizeaza anul (08) clipeste, apasati pe butonul C de cate ori este nevoie pana la aparitia anului curent. Apasati o data pe butonul M pentru alta setare. Incepeti cu aparatul inchis. Tineti apasat pe butonul M 3 secunde, veti auzi un bip si pe ecran vor apare toate simbolurile. Dupa o secunda aparatul va afisa trecerea in modul de executie a setarilor Tineti apasat butonul M pana ce pe ecran va apare cuvantul del, prescurtare de la delete ( stergere ) 14 Pentru inchiderea aparatului, tineti apasat butonul M timp de 3 secunde. 15

9 PREGATIRE Memorarea rezultatului testarilor Daca doriti sa pastrati datele in memorie, alegeti simbolul NO si apasati pe butonul M pentru a trece la pasul urmator. PREGATIRE DAY AVG Dupa aparitia cuvantului del pe ecran aparatul va afisa NO sau YES. Comutati intre aceste optiuni cu ajutorul butonului C. Daca vrem sa stergem toate rezultatele apasam pe butonul M cand pe ecran este afisat simbolul YES. Toate rezultatele vor fi sterse iar pe ecran vor disparea simbolurile. Inchiderea aparatului se va face apasand din nou pe butonul M Setari la final Daca la finalul setarilor apasti butonul M pentru 3 secunde aparatul salveaza setarile si se inchide. 16 Daca doriti sa stergeti rezultatul testului apasati butonul M in momentul in care pe ecran se afla simbolul YES Daca doriti sa pastrati rezultatul testului apasati butonul M in momentul in care pe ecran se afla simbolul NO Nu conteaza pasii urmati la setarea aparatului, el va retine mereu in memorie ultimle setari si se va inchide, indiferent cat de mult tineti apasat butonul M 17

10 PREGATIRE Marcarea rezultatelor speciale Marcarea inainte sau dupa masa. Acest marcaj apare cand vreti sa stiti diferenta de rezultate intre inainte de masa /dupa masa si situatia din prezent. Dupa aparitia rezultatului masuratorii, apasati pe butonul M sau C de doua ori, aceasta ducand la aparitia pe ecran a simbolului. Scoateti banda test si aparatul se va inchide automat. Inlocuirea bateriei Aparatul Healthy Line SHL-800 foloseste o baterie de lithium model CR2032 Semnalul Baterie Consumata 1 Cand energia aparatului nu mai este suficienta, pe ecran va apare simbolul. Din momentul aparitiei acsetui simbol pe ecran, se mai pot face circa 50 de testari, dar se recomanda inlocuirea bateriei cat mai rapid. PREGATIRE Marcarea rezultatelor speciale. Puteti utiliza aceasta functie cand doriti sa va amintiti de rezultatul obtinut in conditii speciale (de exemplu: sport, deshidratare severa etc.). Cand pe ecran va fi afisat rezultatul obtinut in astfel de conditii, apasati pe butonul M sau C o singura data iar simbolul va apare pe ecran. Scoateti banda test si aparatul se va inchide automat. Schimbarea bateriei 2 Inchideti aparatul, desfaceti capacul de pe spate unde se afla bateria. Scoateti bateria uzata si montati noua baterie tinand cont de polaritatea acesteia (partea pozitiva cu fata in sus).apasati capacul in jos si veti auzi un TICK. TICK! La afisarea mediei rezultatelor simbolurile sau nu se afiseaza Dupa inlocuirea bateriei trebuie sa setati din nou data, ora si codul

11 PREGATIRE Probleme Mesajele HY si LO Mesaje de eroare Mesaje Descriere Banda de test este uzata sau distrusa Solutii Inlocuiti banda de test cu una noua Messages Descriptions Cand rezultatul testului da o valoare mai mare de 33.3 mmol/l acesta va afisa simbolul HI Solutions Reluati testarea. Daca din nou va arata simbolul HI atunci consultati urgent un medic. PREGATIRE Picatura de sange a fost aplicata inainte de afisarea simbolului Temperatura mediului in care se face masuratoarea este prea mare sau prea scazuta Aplicati picatura de sange pe banda de test dupa aparitia pe ecran a simbolului respectiv Pentru acomodarea cu mediul tineti aparatul 20 de minute intr-o incapere cu temperatura cuprinsa intre Cand rezultatul testului da o valoare mai mica de 1.1 mmol/l acesta va afisa simbolul Lo Reluati testarea. Daca din nou va arata simbolul Lo atunci consultati urgent un medic. 20 Picatura de sange nu a fost suficienta pentru masuratoare, vascozitatea a fost prea mare sau volumul insuficient Reluati testarea. Daca mesajele de eroare nu sunt suficiente va rugam accesati Healthy Line service la Plaja de masurare a aparatului Healthy Line SHL-G800 este cuprinsa intre: 1.1mmol/L si 33.3mmol/L. 21

12 SPECIFICATII Specificatii Tehnice Produs Sistem de monitorizare a glucozei in sange Model SHL-G800 Proba sange Singe proaspat prin intepatura capilara Volum Proba 0.5 ul Tip TESTER SHL-GS50, SHL-GS Plaja Masurare mmol/l Timp masurare 5 secunde Baterie 3V Baterie Lithium tip (CR2032) Durata Baterie Aprox teste Capacitate Memorie 300 rezultate (inclusiv data si ora) Temp. Operare 10 ~ 40 Umiditate permisa 10% ~ 90 % Temp. Pastrare 4 ~ 30 Dimensiune 15 mm x 54 mm x 86 mm Greutate 45g (cu baterie) TM ealthy ine Congratulations that you have choosen a product from swisshealthcorporation range, this is a TM ealthy ine inspired choice. The swisshealthcorporation products are special made for you, that having as main purpose to offer to you SOLUTIONS FOR PERFECT HEALTH Blood Glucose Monitoring System Model SHL-G800 TM ealthy ine swiss health corporation ENGLISH 22 23

13 CAUTIONS 24 Cautions Usage and storage Medisign MM800 Monitoring System is designed for home usage. Before using your monitoring system, please place it in the environment of system's normal operating temperature ranging (10-40 )for about 20 minutes. Don't allow dust and foreign bodies into test strip slot in order to avoid affecting the system's accuracy. Don't decompose, demolish, repair or transform the system at any time. Don't put the system near any electromagnetic field. (e.g. TV, microwave oven, mobile phone ) Don't allow the monitoring system to collide with others during usage. Please use a soft cotton cloth to wipe the system. Don't use a corrosive product (e.g. Acetone) to wipe the monitoring system. Cautions about the SHL-GSXX Test Strips The test strip is sensitive to humidity; please cover the vial's lid during the storage. Don't allow test strips to be exposed to outside for long time. Take test strips out with clean, dry hands. The validity of the test strip is 18 months under seal, and the validity is 3 months open vial. Please protect test strips to maintain validity. Don't reuse the test strips. This product not recommended for pregnant women, newborns or during severe dehydration. SHL-G800 meter is for use only with SHL-GS50, SHL-GS Blood Glucose Test Strips. Safety Information Before using the system, please read this manual carefully. Don't store the blood glucose monitoring system, test strips, lancing device and lancet in a place where the children can reach easily. Please disinfect instruments and parts for blood collection. The used test strip and lancet should be handled carefully. The SHL-G800 blood glucose monitoring system is for use only outside the body SHL-G800 package content SHL-G800 Carrying Bag Lancing dev. Lancet Test Strips Owner Manual 50 CAUTIONS

14 CONTENT SHL-G800 Products introduction Display 'M' button Front Back Prepare Test Strips 1 Battery lid Tick! SHL-G50() Test Stip Bottle Test strip slot Test strip vial 50 LOT number LOT 'C' button Label Healthy Line MS-1 test strip Before test, match the code on the meter with the code on the test strip vial. When you use the meter at the first time or use the test strip in different vial, adjust code Check Code Open the lid and then remove a test strip 2. Please close lid immediately after removing test strips Be sure the meter code matches the code on the test strip vial. If it does not, then set it to the correct code. 26 Validity Blood collection slot SHL-GS50() test strips only fit SHL-G800 meter Please check the validity of test strips before using. Please write the opening date of the new test strip vial in order to avoid using the expired products. Please read user's manual concerning MS-1 test strips. Insert Test Strips and Adjust Code Beep! Insert a test strip into the strip port. You will hear the sound of beeper and the screen will show the code PREPARE 27

15 PREPARE 50 Adjust Code Blood glucose monitoring system has set up codes from 01 to 70, and the system's default code is. Adjust code using 'M' or 'C' button. Press 'M' button to adjust code up, and press 'C' button to adjust code down. Press and hold 'M' or 'C' button to adjust code quickly. When code is 01, press 'C' button again, the code will become 70. However, when code is 70, press 'M' button again, the code will become 01 The Method of Testing Disinfect Before Test Before test, please clean hands with soap and water and then dry well. You can also use an alcoholic cotton cloth to clean finger. Please wait until the alcohol disappears completely. How to Collect Blood 1 Blod Symbol 1. Unscrew the tip of the lancing device by turning it counterclockwise After choosing the correct code in 3 seconds,the display screen will show the flashing blood symbol. When the blood symbol appears, the meter is ready to test for you While holding the lancet carrier insert a new sterile lancet into the bottom of lancet carrier TESTING 3. Twist off the head of the lancet 28 29

16 SETTING vv 4 4. Put the tip of the lancing device back on and turn it clockwise Add Blood Sample Hold the tip firmly in one hand then pull out the sliding barrel with the other hand. This will cock the lancing device 6. Hold the meter firmly against the side of the finger, with the cap resting on the finger. Press the release button to take a sample Touch the blood drop to the sample channel at the end of the strip. The blood is drawn into the test strip automatically. When you hear the beeper, you can start the test. After 5 seconds, the result will appear. Touch the blood drop to the sample channel at the end of the strip sample channel at the end of the strip. do not drop the blood directly Gently squeeze and massage your fingertip until a round drop of blood forms on your fingertip. Never use a lancet that has been used by someone else. Don't reuse lancets. Do not leave the lancet in the device. Always dispose of the used lancet in a biohazard container. In order to avoid children choking, please store the lancing device in a place where children cannot reach. Proper Blood Sample The test result will appear after the meter counts down 5 seconds, you can hear the sound of beeper, and the screen will show test result, date and time. In the process of counting down, please don't shake it. After showing the test result, please take the strip out. After taking the strip out, the meter will turn off automatically. If the test result is abnormal, please use a new test strip to test again. SETTING 31

17 SETTING. Review & Setting Checking Test Results 5 5. Press 'C' button every time, the screen will show the test result, date and time BEEP! DAY AVG 6 6. After completing the check, press 'M' button, and the meter will turn off. 1. Begin with the meter off. Press 'M' button, and you will hear the beep and the meter will turn on. 2. The screen will display the date and time 3. After 2 seconds, the last 14 days average result will be displayed. 4. Press 'C' button one time, the screen will show the most recent test result, date and time. Press and hold 'C' button, the speed of test results will be accelerated, and the screen will show the overlap speed. If you don't make any changes, the meter will turn off automatically in more than 10 minutes. SETTING 32 33

18 SETTING Setting the Date and Time BEEP! Begin with the meter off, press 'M' button for 3 seconds, you will hear the beep, the screen will show the whole symbol of system. After 1 second, the display screen will show as left picture. Setting the Month When month mode blinks, press and release 'C' Button until correct month appears. Press 'M' button to set and move To date setting mode. Setting the Date When date mode blinks, press and release 'C' button until correct date appears. Press 'M' button to set and move to time setting mode. The Setting Sequence of Date and Time Setting the month Setting the date Setting the time Setting the minute Setting the hour Setting the year Setting the Time The meter can be set in an AM/PM 12-hour default format. When time mode blinks, press 'C' button to shift to 24-hour format. After choosing the time mode, press 'M' button to set and move to hour setting mode. SETTING 34 35

19 SETTING Setting the hour When hour mode blinks, press and release 'C' button until correct hour appears. Press 'M' button to set and move to minute setting mode. Delete Test Results BEEP! Setting the minute 36 When minute mode blinks, press and release 'C' button until correct minute appears. Press 'M' button to set and move to year setting mode. Setting the year Entering the year mode, the screen will show the number '08'. This number stands for the year of Press and release 'C' button until correct year appears. Setting the year from 08 to 20 ( ), after changing the number to '20', press 'C' button again, the number will return to '08' automatically. Begin with the meter off, press 'M' button for 3 seconds, you will hear the beep, the screen will show the whole symbol of system. The screen will show as above picture after about 1 second. Press and hold 'M' button until the screen will show the word 'del' briefly. DELETE 37

20 DELETE 38 4 After the word 'del' appears, the screen will show the symbol 'NO' or 'YES'. (Press 'C' button to switch your option.) 5 6 If you want to delete the test result, press 'M' button when the screen shows the symbol 'YES'. The whole test result will be deleted. DAY AVG After deleting, the screen will show as above picture. Press 'M' button again, the meter will turn off. If you want to delete the test result, please press 'M' button when the screen shows the symbol YES. If you want to store the test result, please press 'M' button when then screen shows the symbol NO. Storing Test Results Setting Complete If you want to store the test result, please choose the symbol 'NO' and press 'M' button again to move the next step. After setting complete, press 'M' button for 3 seconds, the meter stores the setting and turns it off. No matter which steps the meter sets, it will store recent setting and turn it off as long as you press and hold 'M' button. Specification MEMORY 39

21 MEMORY Special Results The mark of before or after meal Replacing Battery Blood glucose meter uses a lithium battery (CR2032). Empty Battery Sign This mark appears when you want to know the different result between before/after meal and present. After the test result appears, press 'M' or 'C' button twice after inserting test strip, the " " appears. And then you can take the test strip out, the meter turns off and stores the test result automatically. 1 Blood glucose meter uses a lithium battery (CR2032). When the energy of battery is not enough, the screen shows and blinks the battery mark. It indicates that the energy left will operate testing about 50 times more. In this period, we suggest that you should be replacing the battery. The mark for special results You can use this function when you want to remember the result under special conditions (for example, sports, medicine, severe dehydration, another people test and so on). When the screen displays the test result, press 'M' or 'C' button one time after inserting test strip, the asterisk mark appears. And then you can take the test strip out, the meter turns off and stores the test result Battery Replacing 2 Turn the meter off. Open the battery cover. Take out the old battery. Put the new battery into the battery slot, and make sure the battery shows positive sign facing upward. Press the battery cover down until you hear TICK. TICK! BATTERY The average of test results doesn't show mark of meal and asterisk. After replacing the battery, the time and code need to be reset

22 TROUBLE SHOOTING Trouble Shooting Error Messages Messages Descriptions Solutions Hi & Lo Messages Messages Descriptions Solutions 42 Test strip is used or damaged. Blood sample was applied to the test strip before the blood drop mark ( ) appeared on the screen. Temperature is too hot or too cold for the system to work properly. The Blood sample did not fill enough during measurement because of abnormally high viscosity or insufficient volume. Replace the new test strip. Apply blood sample to the test strip after the blood drop mark appears on the screen. Put the meter and test strip into the environment of temperature from 10 to 40. You may use it after about 20 minutes. Replace the test strip. When the test result is greater than 33.3mmol/L, the screen will show the Hi mark. It is indicated that the value of your blood glucose is too high. When the test result is lower than 1.1mmol/L, the screen will show the Lo mark. It is indicated that the value of your blood glucose is too low. Replace the test strip. If Hi mark also appears, please call your healthcare professional immediately. The test range of Healthy Line blood glucose meter is from 1.1mmol/L to 33.3mmol/L. Replace the new test strip. If Lo mark also appears, Please call your healthcare professional immediately. If you can not deal with the error messa please access Healthy Line service at TROUBLE SHOOTING

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System GlucCell TM SYSTEM USER S GUIDE Ver 2.1 Intended Use The GlucCell TM Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during cell culture.

More information

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System GlucCell TM SYSTEM USER S GUIDE ver 2.3 Intended Use The GlucCell TM Cell Culture Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during

More information

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only Glucose Meter User Guide Veterinary Monitoring System For dog and cat use only Gpet instruction Manual 31/5/09 18:06 Page 2 Gpet instruction Manual 31/5/09 18:06 Page 3 TABLE OF CONTENTS Your g-pet system

More information

Utilizare ecard in aplicaţie de raportare pentru medicii de Dializa

Utilizare ecard in aplicaţie de raportare pentru medicii de Dializa Utilizare ecard in aplicaţie de raportare pentru medicii de Dializa Cuprins ACTIVARE CARD... 3 AUTENTIFICARE TERMINAL... 5 ADAUGARE PACIENT... 5 ADAUGARE FISA PACIENT... 7 VIZUALIZARE RAPORTARE IN SIUI...

More information

Blood Glucose Monitoring System. User Guide

Blood Glucose Monitoring System. User Guide Blood Glucose Monitoring System User Guide Table of Contents Introduction...2 Important Safety Instructions...2 About ipet PRO Blood Glucose Monitoring System...3 About ipet PRO Meter...4 About the ipet

More information

Owner's Booklet. Blood Glucose Monitoring System. Accurate, complete blood glucose monitoring through advanced biosensor technology

Owner's Booklet. Blood Glucose Monitoring System. Accurate, complete blood glucose monitoring through advanced biosensor technology Owner's Booklet Blood Glucose Monitoring System Accurate, complete blood glucose monitoring through advanced biosensor technology i-sens, Inc. 465-6 Wolgye4-dong, Nowon-gu Seoul 139-845, Korea www.i-sens.com

More information

Items in the package:

Items in the package: Intended Use: The EasyLife Hb Monitoring System is designed for in vitro diagnostic use only (external use only), and is suitable for self-testing. The system is for healthcare professionals and persons

More information

Dear HighQ Check System Owner :

Dear HighQ Check System Owner : Dear HighQ Check System Owner : Thank you for purchasing the HighQ Check Blood Glucose Monitoring System. This manual provides important information to help you to use the system properly. Before using

More information

Logic. Owner s Guide. Blood Glucose Monitor

Logic. Owner s Guide. Blood Glucose Monitor Owner s Guide Logic Blood Glucose Monitor TM You will notice these symbols on your vials of test strips and control solution as well as the label on the back of your BD Logic TM Blood Glucose Monitor.

More information

Blood Glucose & Ketone Monitoring System

Blood Glucose & Ketone Monitoring System Blood Glucose & Ketone Monitoring System Self monitoring of blood glucose is an integral part of diabetes care, but the high cost of testing can make this impossible. At ACON, our goal is to provide high

More information

MDT2. Self-Monitoring Blood Glucose System. Quick Reference Guide

MDT2. Self-Monitoring Blood Glucose System. Quick Reference Guide MDT2 Self-Monitoring Blood Glucose System Quick Reference Guide Inserting Batteries 1. Open the battery door on the back of the meter by pushing the tab in the direction of the arrow. 2. Insert two batteries.

More information

PRIMA Lab SA Via Antonio Monti Balerna Switzerland 0041 (0) primahometest.com

PRIMA Lab SA Via Antonio Monti Balerna Switzerland 0041 (0) primahometest.com PRIMA Lab SA Via Antonio Monti 7 6828 Balerna Switzerland 0041 (0) 91 605 1030 info@primahometest.com primahometest.com prima self-testing kit user manual 2in1 / 3in1 Multiparameter diagnostic device cholesterol

More information

Table of Contents Information Preparation Testing Additional Functions Maintenance

Table of Contents Information Preparation Testing Additional Functions Maintenance Table of Contents Information Important Information: Read This First! 4 Specifications 6 CareSens N POP Blood Glucose Monitoring System 7 Inserting or Replacing the Batteries 8 CareSens N Blood Glucose

More information

ISO IVD 13485: : :2015

ISO IVD 13485: : :2015 ISO ISO 15197:2013 9001:2015 ISO 13485:2016 IVD Table of Contents Important Information About Your Gluco Spark Monitoring System... 1 Important Health-Related Information... 1 Alternate Test Site... 2

More information

Chapter 1 Introduction

Chapter 1 Introduction MASTER 2.2 What You Need for Each Test Operating manual Thank you for choosing the GLUCOCARD TM MX. We have designed this compact blood glucose meter for faster and easier testing of your blood glucose.

More information

Control D. User Manual. Blood Glucose Monitor. Subscribe on MYCONTROL.life HAIDEN

Control D. User Manual. Blood Glucose Monitor. Subscribe on MYCONTROL.life HAIDEN Blood Glucose Monitor User Manual Log using MYCONTROL Mobile App Subscribe on MYCONTROL.life Table of Contents Important Information About Your CONTROL D Glucose Monitoring System... 1 Important Health-Related

More information

Blood Glucose Monitoring System

Blood Glucose Monitoring System Blood Glucose Monitoring System Contents Chapter 1 OMRON Blood Glucose Monitoring System HEA-232 1.1 Introduction 1.2 List of Kit Contents 1.3 Product and Meter Display Chapter 2 Installing and Setting

More information

EasyMax Voice III Self-Monitoring Blood Glucose System. Quick Reference Guide

EasyMax Voice III Self-Monitoring Blood Glucose System. Quick Reference Guide EasyMax Voice III Self-Monitoring Blood Glucose System Quick Reference Guide 1 Installing Batteries 1. Open the battery door on the back of the meter by pushing the tab in the direction of the arrow and

More information

Blood Glucose Monitoring System. Owner s Booklet

Blood Glucose Monitoring System. Owner s Booklet Blood Glucose Monitoring System Owner s Booklet The FreeStyle Freedom Lite Meter and How It Works System Check Screen This display always appears when the meter is turned on. You should check that your

More information

Dear Embrace Owner Embrace N0 Code

Dear Embrace Owner Embrace N0 Code Dear Embrace Owner, Dear Embrace Owner Embrace N0 Code Thank you for choosing the Embrace No Code Blood Glucose Monitoring System to help you manage your diabetes. We designed the Embrace No Code Blood

More information

EME. Self-Monitoring Blood Glucose System. Quick Reference Guide

EME. Self-Monitoring Blood Glucose System. Quick Reference Guide EME Self-Monitoring Blood Glucose System Quick Reference Guide Inserting Batteries 1. Open the battery door on the back of the meter by pushing the tab in the direction of the arrow and pulling the door

More information

Dear HemoSmart GOLD Owner

Dear HemoSmart GOLD Owner Dear HemoSmart GOLD Owner Thank you for choosing the HemoSmart GOLD. All the information that will be needed to use and maintain the HemoSmart GOLD System is included in this manual. Read it carefully

More information

User Instruction Manual. Read this User Instruction Manual carefully before you start testing.

User Instruction Manual. Read this User Instruction Manual carefully before you start testing. User Instruction Manual Read this User Instruction Manual carefully before you start testing. TABLE OF CONTENTS Introduction........................................... 4 Intended Use..........................................

More information

Medisign GH83 BT Blood Glucose Monitoring System User Manual

Medisign GH83 BT Blood Glucose Monitoring System User Manual Medisign GH83 BT Blood Glucose Monitoring System User Manual Read this first: Please keep this instruction for future reference, as it contains important information. Before using this product, read all

More information

VOICE. Blood Glucose Monitoring System. Owner s Manual

VOICE. Blood Glucose Monitoring System. Owner s Manual VOICE Blood Glucose Monitoring System Owner s Manual English Dear FORA Diamond VOICE System Owner: Thank you for purchasing the FORA Diamond VOICE Blood Glucose Monitoring System. This manual provides

More information

User Manual. For single user / home use only

User Manual. For single user / home use only User Manual For single user / home use only Table of Contents Information Important Information:Read this First! 4 Important Health-Related Information 5 Specifications 6 GLUCOCARD Shine Blood Glucose

More information

User Manual. For single user / home use only

User Manual. For single user / home use only User Manual For single user / home use only Welcome to the GLUCOCARD Shine Blood Glucose Monitoring System Thank you for choosing the GLUCOCARD Shine Blood Glucose Monitoring System. The system provides

More information

GM700S USER S MANUAL. Blood Glucose Monitoring System

GM700S USER S MANUAL. Blood Glucose Monitoring System GM700S BIONIME GmbH Tramstrasse 16, 9442 Berneck Switzerland E-mail: info@bionime.ch 0197 101-3GM780-011 EN Rev. Date: September/2014 BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung

More information

PLUS One. Blood Glucose Monitoring System. Owner s Manual

PLUS One. Blood Glucose Monitoring System. Owner s Manual PLUS One Blood Glucose Monitoring System Owner s Manual Dear PLUS One System Owner: Thank you for purchasing the PLUS One Blood Glucose Monitoring System. This manual provides important information to

More information

Important Safety Instructions

Important Safety Instructions Dear Embrace EVO Owner Thank you for choosing the Embrace EVO Blood Glucose Meter to help you manage your diabetes. We designed the Embrace EVO Blood Glucose Meter to be accurate and easy to use. The added

More information

PRIMA. Blood Glucose Monitoring System. Owner s Manual

PRIMA. Blood Glucose Monitoring System. Owner s Manual PRIMA Blood Glucose Monitoring System Owner s Manual English Dear FORA Diamond PRIMA System Owner: Thank you for purchasing the FORA Diamond PRIMA Blood Glucose Monitoring System. This manual provides

More information

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood CoaguChek S System This is a CLIA-waived System Quick Reference Guide Coagulation Testing with Fresh Whole Blood May not print or view at 100% All unmarked prints black. Coag Swoosh prints gradients of

More information

Dear Wellion LEONARDO GLU/CHOL (plus) Owner,

Dear Wellion LEONARDO GLU/CHOL (plus) Owner, OWNER S GUIDE Dear Wellion LEONARDO GLU/CHOL (plus) Owner, Thank you for choosing the Wellion LEONARDO GLU/CHOL (plus) Blood Glucose and Cholesterol Monitoring System to help you easily monitor your blood

More information

Blood Glucose Monitoring System

Blood Glucose Monitoring System Blood Glucose Monitoring System Self monitoring of blood glucose (SMBG) is an important part of diabetes care, but the high cost of testing can make it difficult. At ACON, our goal is to provide high quality

More information

Dear Prodigy System Owner:

Dear Prodigy System Owner: User's Manual Dear Prodigy System Owner: You have chosen one of the best blood glucose monitoring systems available. This booklet has important information about the system. Please read it carefully. Your

More information

Blood Glucose Monitoring System 12:24 PM 10/13/12. mg/dl. Before Meal. See Options. Uses only Contour Next blood glucose test strips USER GUIDE

Blood Glucose Monitoring System 12:24 PM 10/13/12. mg/dl. Before Meal. See Options. Uses only Contour Next blood glucose test strips USER GUIDE Blood Glucose Monitoring System 10/13/12 See Options 12:24 PM mg/dl 93 Before Meal Uses only Contour Next blood glucose test strips USER GUIDE INDICATIONS FOR USE The Contour Next blood glucose monitoring

More information

Blood Glucose Monitoring System

Blood Glucose Monitoring System Blood Glucose Monitoring System Self monitoring of blood glucose (SMBG) is an important part of diabetes care. But the high cost of testing can make this impossible. At ACON, our goal is to provide high

More information

Blood Glucose Monitoring System. mmol/l 5.2. Before Meal. See Options. Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE

Blood Glucose Monitoring System. mmol/l 5.2. Before Meal. See Options. Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE Blood Glucose Monitoring System 13.10.12 12:24 mmol/l 5.2 See Options Before Meal Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE INTENDED USE The CONTOUR NEXT blood glucose monitoring

More information

Blood glucose monitor. MediTouch 2

Blood glucose monitor. MediTouch 2 Blood glucose monitor for self-testing MediTouch 2 Quick Reference Guide GB Art. 79034 0483 EXACT MDD 93/42/EWG WARNING Before using the MediTouch 2 blood glucose monitor from MEDISANA for the first time,

More information

GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL Version 1.0 January, 2010 311-4277100-001 Dear GlucoCheck XL System Owner: Thank you

More information

Blood Glucose Monitoring System

Blood Glucose Monitoring System Blood Glucose Monitoring System Dear Voyage TM System User, Thank you for choosing the Voyage TM system! The Voyage TM blood glucose monitoring system is designed for easy testing of blood glucose and

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use. Blood Glucose Monitoring System Owner's Booklet Instructions for use. Verio IQ Blood Glucose Monitoring System Owner s Booklet 1 Owner s Booklet Thanks for choosing OneTouch! The OneTouch Verio IQ Blood

More information

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5 BRS GM100 Glucose Monitoring System User Instruction Manual Ver. 3.5 TABLE OF CONTENTS Introduction... 3 Intended Use... 3 Understanding the GM100 Glucose Monitoring System... 4 Explanation of the Full

More information

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13 Table of Contents 1. About your HemoSmart Haemoglobin Screening System Contents of Kit...4 HemoSmart Haemoglobin Meter...5 HemoSmart Haemoglobin Test Strip...7 Adjustable Lancing Device and Lancets...8

More information

CentriVet GK Blood Glucose & Ketone Monitoring System

CentriVet GK Blood Glucose & Ketone Monitoring System CentriVet GK Blood Glucose & Ketone Monitoring System FOR ANIMAL USE. NOT FOR HUMAN USE. Welcome and thank you for choosing the CentriVet GK Blood Glucose & Ketone Monitoring System. The CentriVet GK Blood

More information

ACE. Accurate, Compact & Economical Blood Glucose Meter. User Guide

ACE. Accurate, Compact & Economical Blood Glucose Meter. User Guide ACE Accurate, Compact & Economical Blood Glucose Meter User Guide NOTICE: The essential features of the type described and illustrations herein remaining unaltered, Pulsatom Healthcare Pvt. Ltd. reserves

More information

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter Distributed by Zoetis Inc. Kalamazoo, MI 49007 BLOOD GLUCOSE MONITORING SYSTEM SYSTÈME DE SURVEILLANCE DE LA GLYCÉMIE www.alphatrakmeter.com Contact Customer Care at 1-888-963-8471 User Guide For in vitro

More information

GM550 USER S MANUAL. Blood Glucose Monitoring System

GM550 USER S MANUAL. Blood Glucose Monitoring System Blood Glucose Monitoring System BIONIME GmbH Tramstrasse 16, 9442 Berneck Switzerland E-mail: info@bionime.ch 101-3GM550-234 EN BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City

More information

User Manual second language

User Manual second language User Manual second language GlucoTel Blood Glucose Monitoring and Diabetes Management System must be used with cell phones that have: Table of contents 2 3 Introduction 4 Bluetooth Wireless Technology

More information

USER GUIDE. Works with the CONTOUR DIABETES app available for download on the App Store SM or on Google Play.

USER GUIDE. Works with the CONTOUR DIABETES app available for download on the App Store SM or on Google Play. Blood Glucose Monitoring System Works with the CONTOUR DIABETES app available for download on the App Store SM or on Google Play. Uses only CONTOUR NEXT blood glucose test strips. USER GUIDE INTENDED USE

More information

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE Thank you for choosing the Contour blood glucose monitoring system! We are proud to be your partner in helping you manage your diabetes. Our goal is to make this

More information

User s Manual Blood Glucose Meter

User s Manual Blood Glucose Meter User s Manual Blood Glucose Meter Contents Introduction...3 Chapter 1: Your New System...5 Chapter 2: Blood Glucose Tests...13 Chapter 3: Control Tests...25 Chapter 4: Meter Settings...31 Chapter 5: Review

More information

GM700 USER S MANUAL. Blood Glucose Monitoring System GM700

GM700 USER S MANUAL. Blood Glucose Monitoring System GM700 BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Tel: +886 4 23692388 Fax: +886 4 22617586 http: //www.bionime.com E-mail: info@bionime.com Rev. Date: February/2017

More information

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions Blood Glucose Measurement Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions FAQ Omnitest 5 & Omnican Lance CONTENT Omnitest 5 Overview 3 Application Range 5 Target Groups 5 Test Strips 5 Settings

More information

Fraser Health Authority Accu-chek Inform II: Training Script

Fraser Health Authority Accu-chek Inform II: Training Script 1. Introduction Ensure that each participant Signs the attendance Sheet (please PRINT first & last name, and middle initial legibly) Refer to; For Reference Only: o Quick Reference Guide o What s new document

More information

BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL Voice TD-4280 BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL Dear GlucoRx Nexus Voice TD-4280 System Owner: Thank you for using the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System. This manual

More information

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014 Accu-Chek Inform II: Point of Care Glucose Testing Sharp Healthcare 2014 OBJECTIVES At the completion of this module the participant will be able to: Learn the proper technique of performing a finger stick

More information

Prodigy Talking Meter Owner s Manual. Dear Prodigy Owner:

Prodigy Talking Meter Owner s Manual. Dear Prodigy Owner: Dear Prodigy Owner: Thank you for choosing the Prodigy AutoCode Talking blood glucose monitoring system. Please read this manual carefully as it contains important information about your new Prodigy system.

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use Blood Glucose Monitoring System Owner's Booklet Instructions for Use Blood Glucose Monitoring System Owner's Booklet 1 Thanks for choosing OneTouch! The OneTouch Verio Blood Glucose Monitoring System

More information

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter. EasyPlus mini Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear EasyPlus mini SMBG System Owner, Thank you for using

More information

EasyPlus mini 2IN1. Self-Monitoring Blood Glucose System. User s Manual

EasyPlus mini 2IN1. Self-Monitoring Blood Glucose System. User s Manual EasyPlus mini 2IN1 Self-Monitoring Blood Glucose System User s Manual Dear EasyPlus mini 2IN1 SMBG System Owner, Thank you for using the EasyPlus mini 2IN1 Self-Monitoring Blood Glucose (SMBG) System.

More information

Blood Glucose & Ketone Monitoring System. User s Manual

Blood Glucose & Ketone Monitoring System. User s Manual Blood Glucose & Ketone Monitoring System User s Manual Definition of Symbols These symbols are associated with your meter. Batch code This packaging is capable of being recycled Catalog number Manufacturer

More information

User s Manual. Blood Glucose Meter

User s Manual. Blood Glucose Meter User s Manual Blood Glucose Meter This User s Manual features the following 3 symbols: W This symbol indicates a possible risk of injury or of damage to your own health or the health of others. H This

More information

System. User Manual for Self-Testing

System. User Manual for Self-Testing CoaguChek System XS User Manual for Self-Testing Table of Contents CoaguChek XS System User Manual For investigational use only. Not for use in diagnostic procedures. Aspects of the CoaguChek XS System

More information

Blood Glucose Monitoring System. Link the Effects of Food to Glucose Results. Owner s Booklet

Blood Glucose Monitoring System. Link the Effects of Food to Glucose Results. Owner s Booklet Blood Glucose Monitoring System Link the Effects of Food to Glucose Results Owner s Booklet Welcome to the OneTouch family! We know diabetes can be difficult to understand and manage. The right products

More information

USER GUIDE. The NO CODING technology provides accurate and fast blood glucose monitoring. Uses only Bayer s CONTOUR PLUS blood glucose test strips

USER GUIDE. The NO CODING technology provides accurate and fast blood glucose monitoring. Uses only Bayer s CONTOUR PLUS blood glucose test strips Blood Glucose Monitoring System The NO CODING technology provides accurate and fast blood glucose monitoring Uses only Bayer s CONTOUR PLUS blood glucose test strips USER GUIDE INTENDED USE Bayer's CONTOUR

More information

INTRODUCTION: TRUE METRIX

INTRODUCTION: TRUE METRIX INTRODUCTION: TRUE METRIX Self Monitoring Blood Glucose System TRUE METRIX is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to provide quality healthcare

More information

User s Manual. Premium Self-Monitoring Blood Glucose System. Premium Blood Glucose Meter

User s Manual. Premium Self-Monitoring Blood Glucose System. Premium Blood Glucose Meter User s Manual Premium Self-Monitoring Blood Glucose System Premium Blood Glucose Meter Dear DailyChek Premium SMBG System Owner This booklet has important information you must know about DailyChek Premium

More information

User s Manual Blood Glucose Meter

User s Manual Blood Glucose Meter User s Manual Blood Glucose Meter This file may not print or view at 100%. Die lines and color breaks do not print. Holding Area text, box and rules do not print. Roche USA 54082 V2/1 07790953001 07790953001(01)

More information

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter. EasyPlus mini Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear EasyPlus mini SMBG System Owner, Thank you for using

More information

W IMPORTANT INFORMATION FOR PERFORMING A BLOOD GLUCOSE TEST

W IMPORTANT INFORMATION FOR PERFORMING A BLOOD GLUCOSE TEST W IMPORTANT INFORMATION FOR PERFORMING A BLOOD GLUCOSE TEST W An incorrectly performed blood glucose test may lead to incorrect test results which can cause the wrong therapy recommendation to be made

More information

Blood Glucose Monitoring System OWNER S GUIDE

Blood Glucose Monitoring System OWNER S GUIDE Blood Glucose Monitoring System OWNER S GUIDE Key Features of the BGStar No Coding Required - The BGStar doesn t require you to enter a code. Insert a test strip and you are ready to start the test. Pre/Post

More information

INTRODUCTION: McKesson TRUE METRIX Self Monitoring Blood Glucose System

INTRODUCTION: McKesson TRUE METRIX Self Monitoring Blood Glucose System INTRODUCTION: McKesson TRUE METRIX Self Monitoring Blood Glucose System McKesson TRUE METRIX is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to

More information

EasyMax N Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

EasyMax N Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter. EasyMax N Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear EasyMax N SMBG System Owner, Thank you for using the EasyMax

More information

Blood Glucose Monitoring System USER GUIDE. AW A Rev. date: 04/2010. Downloaded from manuals search engine

Blood Glucose Monitoring System USER GUIDE. AW A Rev. date: 04/2010. Downloaded from  manuals search engine Blood Glucose Monitoring System USER GUIDE AW 06629202A Rev. date: 04/2010 Contents: Getting to know your system 1 Setting the time and date, and coding your meter 4 Testing your blood glucose 8 Reviewing

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use Blood Glucose Monitoring System Owner's Booklet Instructions for use Verio Blood Glucose Monitoring System Owner's Booklet 1 Thanks for choosing OneTouch! The OneTouch Verio Blood Glucose Monitoring System

More information

EG V1(BL) User s Manual. Self-Monitoring Blood Glucose System. Please read this User s Manual thoroughly before using your blood glucose meter.

EG V1(BL) User s Manual. Self-Monitoring Blood Glucose System. Please read this User s Manual thoroughly before using your blood glucose meter. EG V1(BL) Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear EG V1(BL) SMBG System Owner, Thank you for using the EG

More information

Owner s Booklet. Wirelessly sends accurate glucose results to MiniMed Paradigm and Guardian Devices. Blood Glucose Monitoring System

Owner s Booklet. Wirelessly sends accurate glucose results to MiniMed Paradigm and Guardian Devices. Blood Glucose Monitoring System TM Blood Glucose Monitoring System Wirelessly sends accurate glucose results to MiniMed Paradigm and Guardian Devices Owner s Booklet Applies to compatible Medtronic MiniMed Paradigm insulin pumps and

More information

Omnitest 5. Blood Glucose Monitoring System

Omnitest 5. Blood Glucose Monitoring System Omnitest 5 Blood Glucose Monitoring System 2 Important notes The Omnitest 5 system provides a quick and easy way to measure the blood glucose level. It can be used for selfmonitoring of blood glucose levels

More information

Blood Glucose Meter Owner s Manual

Blood Glucose Meter Owner s Manual 89115-0055-01 Meter Owner s Manual Preface Thank you for selecting the McKesson Quintet AC Monitoring System. Please read this manual thoroughly before you start testing. This User s Manual provides all

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use Blood Glucose Monitoring System Owner's Booklet Instructions for Use Select Plus Flex Blood Glucose Monitoring System Owner's Booklet 1 Thanks for choosing OneTouch! The OneTouch Select Plus Flex Blood

More information

The performance of Microdot Test Strips has been evaluated both in laboratory and in clinical tests.

The performance of Microdot Test Strips has been evaluated both in laboratory and in clinical tests. Chemical Composition Each Microdot strip contains the enzyme glucose dehydrogenase (Bacillus Sp.) = 1 IU and other ingredients (mediator, NAD, lysing agents etc.) = 200 µg. Test Strips When blood is added

More information

EASY AX SELF-MONITORING BLOOD GLUCOSE SYSTEM USER S MANUAL

EASY AX SELF-MONITORING BLOOD GLUCOSE SYSTEM USER S MANUAL V2 EASY M AX SELF-MONITORING BLOOD GLUCOSE SYSTEM USER S MANUAL Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear

More information

Manual de utilizare Nebulizator cu compresor SHL-NB10

Manual de utilizare Nebulizator cu compresor SHL-NB10 Manual de utilizare Nebulizator cu compresor SHL-NB10 Va multumim ca ati ales un produs din gama "Healthy Line", aceasta este o alegere inspirata. Produsele "Healthy Line" sunt create special pentru dumneavoastra,

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use Blood Glucose Monitoring System Owner's Booklet Instructions for Use Blood Glucose Monitoring System Owner's Booklet 1 Thank you for choosing OneTouch Verio Flex! The OneTouch Verio Flex Blood Glucose

More information

Blood Glucose Monitoring System

Blood Glucose Monitoring System Blood Glucose Monitoring System Thank you for choosing the On Call Pro Blood Glucose Monitoring System. The System will provide accurate blood glucose results in just a few simple steps. The On Call Pro

More information

User s Manual Please read this User s Manual thoroughly before using your blood glucose meter.

User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Self-Monitoring Speaking Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter. Dear EasyMax V SMBG System Owner, Thank you for using the EasyMax

More information

Blood Glucose and ß -Ketone Monitoring System. Owner s Manual

Blood Glucose and ß -Ketone Monitoring System. Owner s Manual Blood Glucose and ß -Ketone Monitoring System Owner s Manual English Dear Care Touch System Owner: Thank you for choosing the Care Touch Blood Glucose and ß-Ketone Monitoring System. This manual provides

More information

Align Gluco-Monitoring System (BG1) Quick Start Guide

Align Gluco-Monitoring System (BG1) Quick Start Guide EN Align Gluco-Monitoring System (BG1) Quick Start Guide WELCOME Welcome to your ihealth Align Gluco-Monitoring System (the ihealth system). The ihealth system is designed to be used with the free ihealth

More information

Integrated Multiparameter Monitoring System. Owner s Manual

Integrated Multiparameter Monitoring System. Owner s Manual Integrated Multiparameter Monitoring System Owner s Manual Dear GlucoRx HCT Connect System Owner: Thank you for choosing the GlucoRx HCT Connect Integrated Multiparameter Monitoring System. This manual

More information

Dear Wellion GALILEO GLU/KET (plus) Owner,

Dear Wellion GALILEO GLU/KET (plus) Owner, OWNER S GUIDE Dear Wellion GALILEO GLU/KET (plus) Owner, Thank you for choosing the Wellion GALILEO GLU/KET (plus) Blood Glucose and Ketone Monitoring System to help you easily monitor your blood sugar

More information

Align Gluco-Monitoring System (BG1) Quick Start Guide

Align Gluco-Monitoring System (BG1) Quick Start Guide EN Align Gluco-Monitoring System (BG1) Quick Start Guide WELCOME Welcome to your ihealth Align Gluco-Monitoring System (the ihealth system). The ihealth system is designed to be used with the free ihealth

More information

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use Blood Glucose Monitoring System Owner's Booklet Instructions for Use Verio Flex Blood Glucose Monitoring System Owner's Booklet 1 Thanks for choosing OneTouch! The OneTouch Verio Flex Blood Glucose Monitoring

More information

5.2mmol/L. 5.2 mmol USER GUIDE. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System

5.2mmol/L. 5.2 mmol USER GUIDE. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System Wireless Blood Glucose Monitoring System 5.2 mmol L Before Meal 12:00 PM l 10/13 Bolus Bolus Reminder Notes 12:00 PM l 10/13 12:00 PM BG 5.2mmol/L Active Insulin 1.5 u Bolus Basal Uses only CONTOUR NEXT

More information

Blood Glucose Monitoring System USER GUIDE. AW A Rev. date: 01/2017 AW A

Blood Glucose Monitoring System USER GUIDE. AW A Rev. date: 01/2017 AW A Blood Glucose Monitoring System USER GUIDE AW 06629404A Rev. date: 01/2017 AW 06629404A Contents: Getting to know your system 1 Setting the time and date, and coding your meter 4 Testing your blood glucose

More information

5.2 mmol USER GUIDE. 5.2 mmol/l. Bolus Reminder Notes. 12:00 PM l 10/13. Uses only Contour Next blood glucose test strips.

5.2 mmol USER GUIDE. 5.2 mmol/l. Bolus Reminder Notes. 12:00 PM l 10/13. Uses only Contour Next blood glucose test strips. Wireless Blood Glucose Monitoring System 12:00 PM l 10/13 5.2 mmol Before Meal L Bolus Reminder Notes 12:00 PM BG 5.2 mmol/l Active Insulin 1.5 u MiniMed 670G Pump is shown USER GUIDE Uses only Contour

More information

User s Manual Please read this User s Manual thoroughly before using your blood glucose meter

User s Manual Please read this User s Manual thoroughly before using your blood glucose meter EME Self-Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter Dear EME SMBG System Owner, Thank you for using the EME Self-Monitoring

More information

GM260 USER S MANUAL. Blood Glucose Monitoring System

GM260 USER S MANUAL. Blood Glucose Monitoring System Blood Glucose Monitoring System BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Tel: +886 4 23692388 Fax: +886 4 22617586 http: //www.bionime.com E-mail: info@bionime.com

More information

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips BeneCheck BK6-12M Plus Multi-Monitoring Meter and Strips The BeneCheck BK6-12M multi-monitoring system is an easy to use, handheld device which allows you to check your Total Cholesterol, as well as Blood

More information

Blood Glucose Monitoring System. User s Manual for Single Patient Use Only Blood Glucose Meter

Blood Glucose Monitoring System. User s Manual for Single Patient Use Only Blood Glucose Meter Blood Glucose Monitoring System User s Manual for Single Patient Use Only Blood Glucose Meter Contents Important Safety Information...3 Chapter 1: Your New System...9 Chapter 2: The Accu Chek FastClix

More information