Quantitative Measurement of Emergency Biomarkers in Parallel
|
|
- Gilbert Garrett
- 5 years ago
- Views:
Transcription
1 Point-of-Care Immunoassay Analyzer Quantitative Measurement of Emergency Biomarkers in Parallel Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole blood samples 6 parallel channels allows either 6 samples or 6 tests for one sample to be run simultaneously 99th percentile, guideline acceptable Troponin I results available at point-of-care
2 Point-of-Care Immunoassay Analyzer Critical Results Faster The PATHFAST is an easy to use, bench-top, chemiluminescent immunoassay analyzer that rapidly measures concentrations of emergency biomarkers from a single whole blood sample. With a 17 minute turnaround time, critical results are available to the caregiver quickly, enhancing patient care. Parallel Processing for Fast Action and Flexibility The PATHFAST system is efficient and flexible. It features six parallel channels, allowing for six quantitative analyses simultaneously, with results in 17 minutes. The flexibility of the system enables the laboratory to run either six samples at one time, or six parameters for one patient simultaneously. Point-of-Care The PATHFAST s compact design and quick turnaround time make it the ideal system in emergency departments, hospital laboratories and core laboratories. It can be used wherever fast, quantitative results for the critical care of patients are required. Equipment and Networking The PATHFAST features an integrated computer and printer, operated by a touchscreen monitor. Barcoded samples are read by handheld scanner. An RS-232C interface allows it to be easily connected to an LIS (Laboratory Information System). Networking enables direct data transfer to the central lab with access to results from any PC. Principle and Precision PATHFAST is a fully automated immunoassay analyzer, which combines progressive chemiluminescence technology with patented Magtration technology. Small sample volumes can be detected with high accuracy and precision, while the device and the reagent cartridges provide optimum sensitivity. Results are reproducible and correlate well with lab analyses. Operation and Safety The effortless operation of the PATHFAST consists of a three step method. To use, add the sample to the reagent cartridge, insert the cartridge into the analyzer and press the Start button. PATHFAST takes care of everything else automatically. There are no additional reagents, buffer solution or sample pipettes (e.g. capillaries) required and a water connection or drain is not necessary. Lab personnel are not required to have any special skills or certifications. The PATHFAST is operationally safe and is virtually maintenance free. Best of all, lab quality results are available in only 17 minutes from whole blood samples.
3 PATHFAST determines the quantity of Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP and hscrp from one single whole blood sample. The quantitative data of the parallel analyses provide results within minutes, which facilitates the critical care decision for patients with acute coronary syndrome, venous thromboembolism and suspected coronary insufficiency. Available Markers Troponin I Measurements of cardiac Troponin I are used as an aid in the diagnosis of acute myocardial infarction (AMI). Troponin I is released rapidly to blood circulation several hours after the onset of AMI. D-Dimer The D-Dimer concentration is an indicator for the fibrinolytic activity of plasmin in the vascular system. Elevated concentrations of D-Dimer indicate increased coagulatory and fibrinolytic activity. In general, a validated D-Dimer assay may be useful in assisting with the diagnosis of deep vein thrombosis and pulmonary embolism ng/ml μg/ml FEU Sample #1 #2 #3 #4 Total % CV in plasma 7.1% 6.1% 5.4% 3.9% Troponin means in ng/ml Correlation vs. Stratus CS y = 0.947x 0.005; r = 0.994; n = 57 Myoglobin Myoglobin is one of the first markers associated with myocardial necrosis to rise above normal levels. The measurement of Myoglobin can be used as a rapid and sensitive test in the early phase of AMI. 5 1,000 ng/ml QC-L QC-M QC-H Total % CV in plasma 4.3% 3.8% 2.4% MYO means in ng/ml Correlation vs. Stratus CS y = 1.046x ; r = 0.996; n = 60 CK-MB CK-MB is found predominantly in cardiac muscle cells accounting for approximately 10-40% of myocardial CK. Low concentration of CK-MB in healthy subjects is an aid for the diagnosis and monitoring of myocardial injury. QC-LL QC-L QC-M QC-H Total % CV in plasma 6.1% 6.0% 4.5% 7.1% D-Dimer means in μg/ml FEU Correlation vs. Stratus CS y = 1.01x ; r = ; n = 235 NTproBNP The result obtained with the assay is an aid to assist in the diagnosis and assessment of severity of congestive heart failure (CHF) and risk stratification in patients with acute coronary syndrome (ACS) ,000 pg/ml QC-LL QC-L QC-M QC-H Total % CV in plasma 4.7% 3.4% 4.6% 5.4% NTproBNP means in pg/ml Correlation vs. Elecsys y = 1.046x ; r = 0.985; n = 346 hscrp Measurement of CRP by a high sensitivity CRP assay may add to the predictive value of other markers used to assess the risk of cardiovascular and peripheral vascular diseases ng/ml mg/l QC-L QC-M QC-H QC-LL QC-L QC-M QC-H Total % CV in plasma 8.4% 6.4% 6.9% CK-MB means in ng/ml Correlation vs. Stratus CS y = 1.007x 0.274; r = 0.988; n = 60 Total % CV in serum 7.4% 8.1% 8.5% 5.3% hscrp means in mg/l Correlation vs. IMMULITE y = 1.01x 0.056; r = 0.990; n = 60
4 PATHFAST Test Principle Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Diagnostic safety through parallel scanning of all significant markers
5 Reagent Cartridge Magnetic particles ALP-conjugated antibody Chemiluminescent substrate Sample Diluent Sample Well Washing Buffer Counting Well Technical Specifications Instrument type: Bench-top Immunoassay Analyzer Throughput: Up to 6 samples or parameters per run Measuring time: Less than 17 min for 6 samples using emergency markers Sampling material: Whole blood, plasma, serum Measuring principle: Chemiluminescence enzyme immunoassay technology (CLEIA) and Magtration technology Reaction temperature: 37.5 C Sample volume: 100 μl Wavelength: nm Data storage: Patient data: 1000 QC data: 1800 CAL data: 300 Data transfer: ASTM standard Dimensions: 375 (w) x 570 (d) x 510 (h) mm Weight: 33 kg Electrical requirements: Vac Power consumption: 360 Vac Monitor/keyboard: LCD touch-screen Printer: Integrated PC: Integrated Interface: RS-232C Calibration: Factory calibration, 2-point calibration every 4 weeks 24-h operation (stand-by): Recommended Future Markers The PATHFAST features an expanding menu. Coming soon new assays for fertility and sepsis indication.
6 Point-of-Care Immunoassay Analyzer Product List PATHFAST for critical care diagnostics Item number Pack size SYSTEM PATHFAST Immunoassay Analyzer Analyzer for the measurement of cardiac and other emergency parameters x 1 REAGENT KITS PATHFAST ctnl-ii PF1101-K 60 tests PATHFAST Myo-II PF1111-K 60 tests PATHFAST CK-MB-II PF1121-K 60 tests PATHFAST D-Dimer PF1051-KUS 60 tests PATHFAST NTproBNP PF1061-KUS 60 tests PATHFAST hscrp PF1071-KUS 60 tests CONSUMABLES AND ACCESSORIES PATHFAST Tips x 42 units PATHFAST Waste Box units PATHFAST Roll Paper rolls Distributed : By: 27 Wellington Road, Lincoln, RI Tel: : Fax: Manufactured By: Mitsubishi Chemical Medience Corporation, Tokyo, Japan Vital Diagnostics, Inc. All rights reserved. Vital Diagnostics is a registered trademark of Vital Diagnostics. PATHFAST is a registered trademark of Mitsubishi Chemical Medience Corporation. Magtration is a registered trademark of Precision System Science Co., Ltd. Stratus and IMMULITE are registered trademarks of Siemens Healthcare Diagnostics Inc. Elecsys is a registered trademark of Roche Diagnostics GmbH. Specifications subject to change without notice. L7323, Rev. A
Quantitative Measurement of Cardiac Biomarkers
Cardiac Biomarker Analyzer Quantitative Measurement of Cardiac Biomarkers Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole blood samples 6 parallel
More informationThe PATH to better cardiac care starts here
The PATH to better cardiac care starts here #1 for precision among point-of-care analyzers * Affordable, core-lab quality results in under 17 minutes Test menu: Troponin I, NTproBNP, CK-MB, D-Dimer, hscrp
More informationQuantitative measurement of 6 analytes in parallel
Quantitative measurement of 6 analytes in parallel Trop I sensitive, NTproBNP, D-Dimer, hscrp, Myoglobin, HCG, CK-MB mass NEXT GENERATION PATHFAST TM emergency & CRITICAL CARE» 6 samples in parallel» in
More informationNEW SEPSIS MARKER PATHFAST PRESEPSIN
Fast and quantitative results out of whole blood in 17 minutes For routine laboratory and point of care use NEW SEPSIS MARKER PATHFAST PRESEPSIN» Diagnosis & early prognosis» Risk stratification» Patient
More informationQuantitative measurement of 6 analytes in parallel hs Trop I, NTproBNP, D-Dimer, hscrp, Myoglobin, HCG, CK-MB mass
Quantitative measurement of 6 analytes in parallel hs Trop I, NTproBNP, D-Dimer, hscrp, Myoglobin, HCG, CK-MB mass High Sensitivity NEW MARKER Tr o p o n in I EMERGENCY & CRITICAL CARE» 6 samples in parallel»
More informationhs-c Tn I high sensitivity troponin I <17 min
hs-c Tn I high sensitivity troponin I IFCC & ESC compliant 0/ h NSTEMI rule-out / rule-in algorithm POCT whole blood/plasma Results in < 7 minutes
More informationcobas h 232 POC system The power to make decisions in cardiac emergencies
cobas h 232 POC system The power to make decisions in cardiac emergencies cobas h 232 POC system Rapid results at the Point of Care (POC) Wherever and whenever you face an emergency situation, measurement
More informationThe Quidel Triage System
The Quidel Triage System Automated. Calibrated. Connected. Professional diagnostics at the point-of-care BR1026500EN00.qxp_Layout 1 8/28/18 2:28 PM Page 4 The Quidel Triage System Fast quantitative results
More informationSmart Diagnostics for Point-of-Care!
Smart Diagnostics for Point-of-Care! The one special multi-parameter Point-of-Care (POC) instrument that covers the constantly expanding range of applications with the highest precision. Designed for HbA1c
More informationBio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems
Bio-Rad Laboratories Cardiac Assessment Controls Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central
More informationINTERNATIONAL PRODUCT CATALOG
INTERNATIONAL PRODUCT CATALOG Quidel is a leading manufacturer of diagnostic healthcare solutions serving to enhance the health and well-being of people around the globe through the development of diagnostic
More informationAlere Triage System. Knowing now matters when rapid treatment decisions can be made at the point-of-care.
System Knowing now matters when rapid treatment decisions can be made at the point-of-care. The Alere Triage System The MeterPro is utilized in thousands of healthcare facilities worldwide. A comprehensive
More informationMADE IN KOREA. Advanced POCT. Automated 6 Channels. Automated Single Channel. POCT to Desktop. Our technology covers it all!
MADE IN KOREA Advanced POCT Automated 6 Channels Automated Single Channel POCT to Desktop Our technology covers it all! Compact Desktop Immuno- Automated desktop 6 channels 2 bays Bay random access Run
More informationAFIAS 6 (Automatic Fluorescence Immuno-Assay)
AFIAS 6 (Automatic Fluorescence Immuno-Assay) Each SMART kit contains ten (10) cartridges, one (1) ID Chip, and one (1) instruction for use AFIAS 6 (Automatic Fluorescence Immuno-Assay) is a next-generation,
More informationCardiac Assessment Controls
Bio-Rad Laboratories CARDIAC ASSESSMENT CONTROLS Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central
More informationS M A R T. tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free. Revolution in Diagnostics
S M A R T tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free Revolution in Diagnostics Conventional Diagnosis Patient visits the lab's local sample
More informationThe next generation portable diagnostics system: Over 20 parameters available!
www.boditech.co.kr Immunofluorescence Assay System The next generation portable diagnostics system: Over 20 parameters available! Quantitative test results on the spot is an immunofluorescencebased diagnostics
More informationPOC Testing: The New Standard. InnovaStar From DiaSys.
POC Testing: The New Standard. InnovaStar From DiaSys. Easy to use, superior precision, rapid results: InnovaStar from DiaSys brings POC testing to a whole new level. A fully automatic, compact analyzer
More informationMultiple studies are available concerning the use of
SPECIAL ARTICLE Evaluation of the Biosite Ò Quantitative Whole Blood D-dimer Assay and Comparison With the biomérieux VIDAS Ò D-dimer Exclusion Test Validation and Utility For Use in the Central Laboratory
More informationI know my value CoaguChek XS Pro system
I know my value CoaguChek XS Pro system The smart way to manage your anticoagulation clinic CoaguChek XS Pro system A barcode scanner can make a difference There has been an extraordinary increase in the
More informationDetection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.
personal Detection Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily. An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science
More informationTHE SEPSIS MARKER PATHFAST TM PRESEPSIN
THE SEPSIS MARKER PATHFAST TM PRESEPSIN» Whole blood» Early prognosis» Risk stratification» Patient monitoring What is PATHFAST TM Presepsin? PATHFAST TM Presepsin is a chemiluminescent enzyme immunoassay
More informationMove on from. based treatment
Product class Test items Diseases Tn-l CK-MB Myoglobin Thrombosis hs-crp Cardiovascular Inflammation PSA Prostate cancer AFP Liver cancer CEA Colorectal cancer Microalbumin HbA1c Cortisol Metabolism Total
More informationCardiac Assessment Controls A critical element of reliable cardiac testing
Cardiac Assessment Controls Cardiac Assessment Controls A critical element of reliable cardiac testing Choose the products best suited for your cardiac assessment needs Each year, 17.7 million people on
More informationcobas h 232 system When on the spot cardiac decisions need on the spot results in Primary Care cobas cardio
cobas h 232 system When on the spot cardiac decisions need on the spot results in Primary Care Is there a better pathway? Without Point of Care (POC) testing Patient presents Blood sample taken Lab collects
More informationBLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.
BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S. Introducing the DxH 500, an Open-vial Hematology System *. Quality 5-part Differential in a Compact Design The first
More informationCaris 200 Fully Automated Chemiluminescence Immunoassay (CLIA) System
Caris 200 Fully Automated Chemiluminescence Immunoassay (CLIA) System Learn more at: www.ystwt.cn Flexible Efficient Reliable Developing Scientifically Focusing on the Health Methods Principle: CLIA with
More informationImmunoCAP Systems. Optimized for allergy testing - Precision - Accuracy - Consistency
ImmunoCAP Systems Optimized for allergy testing - Precision - Accuracy - Consistency 1 The ImmunoCAP systems from Phadia offer an optimal allergy testing solution for every laboratory, regardless of testing
More informationBiocard. 1. Troponin I
Biocard http://www.anibiotech.fi Biocard Quant Reader is a quantitative desktop reader for all Biocard rapid cardiac tests: Troponin I, Myoglobin, CRP, hscrp, MPO and CK-MB. It has a embedded printer and
More informationCyBio Felix Your Automated Application Starts Here
Title Label Lab Automation CyBio Felix Your Automated Application Starts Here 2 CyBio FeliX Future-Proof Liquid Handling Automation Transform your manual workflows to automated processes on your benchtop!
More informationIntended use. Summary and explanation of test
NESPI-FRCT-001EN(V.0.1) Intended use The FREND Cardiac Triple test is a fluorescent nanoparticle immunoassay designed for in vitro quantitative measurement of myoglobin, troponin I, and creatine kinase
More informationAbaxis Piccolo xpress TM
Abaxis Piccolo xpress TM A breakthrough in point-of care diagnostics A breakthrough in point of care diagnostics Fast, easy, accurate on-site testing The Piccolo xpress TM is a fully automated system,
More informationMETHOD FOR THE MEASUREMENT OF BEDSIDE TROPONIN T (cobas h232)
Page 1 of 6 METHOD FOR THE MEASUREMENT OF BEDSIDE TROPONIN T (cobas h232) Edition No: 1.3.1 Author: Rosy Tirimacco / Paul Simpson Date: April 2012 Operative Date: April 2012 Review Date: November 2012
More informationGlucose analyser GA 3
Glucose analyser GA 3 NEW The GA 3 from KABE LABORTECHNIK for a precise determination of glucose and lactate values Precise, fully automated, quick and economical the GA 3! The GA 3 represents a further
More informationType of panel. Characteristics. Technology
Type of panel 50 lines Panel: 44 specific allergens including Total IgE PROTIA Allergy-Q Total 48 allergens 64 lines Panel: 64 specific allergens including Total IgE PROTIA Allergy-Q64 Total 64 allergens
More informationPoint-of-Care Test Products. Article List
Point-of-Care Test Products Article List Version October 31st, 2017 Eurolyser Diagnostica GmbH Bayernstrasse 11a 5020 Salzburg Austria Phone +43 662 432100 Fax +43 662 432100 50 www.eurolyser.com point-of-care
More informationDräger Alcotest 6820 Alcohol Screening Device
Dräger Alcotest 6820 Alcohol Screening Device Dräger Alcotest 6820 is the logical successor to the successful Alcotest 6810. The compact hand-held measuring instrument Alcotest is quickly ready for use
More informationReferences Required document for Laboratory Accreditation by the College of American Pathologists.
Subject NT-proBNP Cobas e601 Index Number Lab-4011 Section Laboratory Subsection Chemistry Category Departmental Contact Benjamin Michel Last Revised 10/19/2016 References Required document for Laboratory
More informationAlere Technologies GmbH
Alere Technologies GmbH Mobile Smart Instruments for Automated Image Analysis and Point of Care Diagnosis April 2011 Alere Technologies GmbH Alere Technologies GmbH Based in Jena, Thuringia, Germany ~300
More informationThyroid Stimulating Hormone (S-TSH) Thyroid Stimulating
ab108659 Thyroid Stimulating Hormone (S-TSH) Human ELISA Kit Instructions for Use For the quantitative measurement of Human Thyroid Stimulating Hormone (S-TSH) concentrations in serum. This product is
More informationWhat can we learn from EQAs and audits for cardiac marker testing?
What can we learn from EQAs and audits for cardiac marker testing? Dr P. O. Collinson MA MB BChir FRCPath MD FACB Consultant Chemical Pathologist and Director of Clinical Blood Sciences, Head of Vascular
More informationNEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections
NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER Rapid and reliable diagnosis of Helicobacter pylori infections Help prevent chronic Helicobacter pylori infections and the development of gastric cancer More
More informationDWS, Additive Manufacturing. Smart, Effective and Italian.
DWS DFAB PROFILE DWS, Additive Manufacturing. Smart, Effective and Italian. Reducing development times for new products and cutting time to market have become top priorities, strategic and non-deferrable
More informationELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE
ELECTRONIC PIPETTE The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE DELIVER ON-TARGET PERFORMANCE PIPETMAN M has been designed
More informationAuto HbA1C ANALYZER HbA1LC HPLC 3660
Turnkey Laboratories Solutions Auto HbA1C ANALYZER HbA1LC HPLC 3660 Viewable Accuracy Real Time Summarized Chromatogram Authentic Results EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES
More informationHI Total Acidity Mini Titrator for Water Analysis
HI 84530 Total Acidity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the
More informationHPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes
HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c First HPLC Analyzer to Aid in Diagnosis of Diabetes TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct
More informationBiomarkers in Acute Cardiac Disease Samir Arnaout, M.D.FESC Associate Professor of Medicine Internal Medicine i & Cardiology American University of Beirut Time course of the appearance of various markers
More informationILyte TM Automated electrolyte analyzers
ILyte TM Automated electrolyte analyzers The IL program for electrolyte analysis. Worry Free, Easy to Use Maintenance Free Electrodes ILyte Na +, K + analyzer ILyte Na +, K +, Cl - analyzer ILyte Na +,
More informationUse of Biomarkers for Detection of Acute Myocardial Infarction
Use of Biomarkers for Detection of Acute Myocardial Infarction Allan S. Jaffe, MD.* Consultant - Cardiology & Laboratory Medicine Professor of Medicine Chair, CCLS Division, Department of Laboratory Medicine
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 14 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationBC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER
www.accuniq.com BC380 The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER Multi-Frequency Segmental Body Composition Analysis using BIA Technology 02 Product Introduction ACCUNIQ BC380
More informationTroponin when is an assay high sensitive?
Troponin when is an assay high sensitive? Professor P. O. Collinson MA MB BChir FRCPath FRCP edin MD FACB EurClin Chem Consultant Chemical Pathologist and Professor of Cardiovascular Biomarkers, Departments
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.
More informationhuman Total Cathepsin B Catalog Number: DY2176
human Total Cathepsin B Catalog Number: DY2176 This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human Total
More informationARK Methotrexate Assay Application Ortho Clinical Diagnostics VITROS 5600 Integrated System and VITROS 4600 Chemistry System
C ARK Methotrexate Assay Application Ortho Clinical Diagnostics VITROS 5600 Integrated System and VITROS 4600 Chemistry System Reference No. 5026000100 Intended for the Quantitative Determination of Methotrexate
More informationRat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN
YK051 Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC. 2480-1 AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN 418 0011 Contents Introduction 2 Characteristics 3 Composition 4 Method 5-6 Notes
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 13 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationFOR LABORATORY USE ONLY
YK060 Insulin ELISA FOR LABORATORY USE ONLY Kasumigaseki Place, 3-6-7, Kasumigaseki, Chiyoda-ku Tokyo 100-0013 Japan URL: http://www.sceti.co.jp/export/ e-mail: medical@sceti.co.jp Contents
More informationGE Healthcare. Total-access ultrasound LOGIQ e compact ultrasound system for general imaging and shared services.
GE Healthcare Total-access ultrasound LOGIQ e compact ultrasound system for general imaging and shared services. Opening possibilities. Where should an ultrasound exam be performed? And how big does a
More informationIV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.
Definitions Instructions for use REF Catalogue number IV2-113E Use by English Invitron Glargine ELISA Kit For in-vitro diagnostic use Σ 96 LOT IVD Lot/Batch Code Storage temperature limitations In vitro
More informationACCESS hstni SCIENTIFIC LITERATURE
ACCESS hstni SCIENTIFIC LITERATURE 2017 2018 Table of contents Performance Evaluation of Access hstni A critical evaluation of the Beckman Coulter Access hstni: Analytical performance, reference interval
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationDräger Alcotest 5510 Alcohol Screening Device
Dräger Alcotest 5510 Alcohol Screening Device The Dräger Alcotest 5510 handheld screener provides the quality, accuracy, and reliability that our customers have come to expect from our breath alcohol detection
More informationFertility Diagnostics
Fertility Diagnostics Fertility hormones measured on PATHFAST For internal use only Diagnostics PATHFAST Chemiluminescence-immuno-analyzer 1 Content: page 1. Fertility hormones - general aspects 1.1 Reproductive
More informationGentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000
v2-jan214 Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4 Intended Use The canine CRP immunoassay on Abbott's Architect c4 is an in vitro diagnostic test for quantitative determination
More informationQUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)
TURNING ON/OFF, CHARGING THE DEVICE On/off button on right side Power supply connector START MENU Current time Battery status Select patient Customize settings Turn off device TESTING Additional information
More informationAutotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from
Technical Information and Specifications detailed specification sheets from www.malvern.co.uk/autotitrator MPT-2 Autotitrator Description The MPT-2 autotitrator is an optional accessory compatible with
More informationDräger Alcotest 9510 Evidential Alcohol Measuring Device
Dräger Alcotest 9510 Evidential Alcohol Measuring Device The Dräger Alcotest 9510 is an advanced breath alcohol measuring instrument for evidential applications. It is designed to comply with national
More information7/31/2018. Overview of Next Generation Cardiac Troponin T High Sensitivity. Disclosures. Course Objectives: high sensitive Troponin T assay
Overview of Next Generation Cardiac Troponin T High Sensitivity Arleen Francis Medical & Scientific Liaison Roche Diagnostics 1 Disclosures Arleen Francis is an employee of Roche Diagnostics and a member
More informationfor therapeutic drug monitoring
Thermo Scientific TDM Assays for Therapeutic Drug Monitoring Complete solutions for therapeutic drug monitoring TDM tests provide quantitative results to ensure beneficial therapeutic effects by determining
More informationThe Adiponectin Turbidimetric Immunoassay Reagent Kit
The Adiponectin Turbidimetric Immunoassay Reagent Kit Catalogue number: 51010 For the quantitative determination of Adiponectin in human serum and plasma This package insert must be read in its entirety
More informationNEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference
NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: www.fishersci.com/handleanything Achieve newfound confidence
More informationHI Titratable Acidity Mini Titrator for Fruit Juice Analysis
HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts
More informationThyroxine (T4) Human ELISA Kit
ab108662 Thyroxine (T4) Human ELISA Kit Instructions for Use For the quantitative measurement of Human Thyroxine (T4) concentrations in serum. This product is for research use only and is not intended
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 15 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More information25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual
Page 1 / 12 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual ZV-4027-0500-10 500 2-8 C Page 2 / 12 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...
More informationMass Spectrometry Made Simple for Clinical Diagnostic Labs
Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics
More information3D PRINTING SOLUTIONS
3D PRINTING SOLUTIONS TRANSFORMING CREATIVITY 3D PRINTING FAST AND EFFICIENT PRODUCTION The high speed, accuracy, and reliability of the new Dental Wings professional grade 3D Printers are combined with
More informationThe Rapid D-Dimer Test is a chromatographic immunoassay for the qualitative detection of D-Dimer in human whole blood and plasma.
D-Dimer Rapid Test Cat. No.:DTS589 Pkg.Size: Intended use The Rapid D-Dimer Test is a chromatographic immunoassay for the qualitative detection of D-Dimer in human whole blood and plasma. General Description
More informationQMS TACROLIMUS APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800
QMS TACROLIMUS APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800 Beckman Coulter Reagent REF A53727 The QMS Tacrolimus Immunoassay is intended for the quantitative determination of tacrolimus in human whole
More informationNext Generation Rapid Diagnostics
Next Generation Rapid Diagnostics INTERNATIONAL PRODUCT CATALOG Quidel is a leading manufacturer of diagnostic healthcare solutions serving to enhance the health and well-being of people around the globe
More informationAmantadine ELISA Test Kit
Amantadine ELISA Test Kit Catalog No. LSY-10052 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Amantadine. The coupling antigen is pre-coated on the micro-well
More informationProcedures: LifeSign MI Myoglobin/CK-MB/Troponin I Test. Prepared by Date Adopted Supersedes Procedure # Review Date Revision Date Signature
Procedures: LifeSign MI Myoglobin/CK-MB/Troponin I Test Prepared by Date Adopted Supersedes Procedure # Review Date Revision Date Signature Distributed to # of Copies Distributed to # of Copies PRINCIPLE:
More information02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2
For detection and measurement of human interleukin 2 Catalog #02006 Catalog #02007 2 Plates 10 Plates Product Description The Human Interleukin 2 (IL-2) ELISA Kit is designed for the quantitative detection
More informationQUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only
QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only Test Procedure Study the Package Insert and User Manual thoroughly before using Quick Reference Instructions. This is not a complete
More information3D PRINTING TRANSFORMING CREATIVITY
3D PRINTING TRANSFORMING CREATIVITY 3D PRINTING The high speed, accuracy, and reliability of the new Dental Wings professional grade 3D printers are combined with multiple certified materials, enabling
More informationVeterinary Immunofluorescence Quantitative Analyzer
Applicability Hormone Test Item Cortisol T4 Reaction Time Diseases Cushing's Syndroe, Edison Syndrome Hypothyroidism, Hyperthyroidism. Sample vol Specimen Type Detection Range 10~1000nmol/L 8~100nmol/L
More informationTable. Analytical characteristics of commercial and research cardiac troponin I and T assays declared by the manufacturer.
Table. Analytical characteristics of commercial and research cardiac troponin I and T assays declared by the manufacturer. Commercially available assays - Company/ platform(s)/ assay LoB a LoD b 99 th
More informationWHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: Alere q HIV-1/2 Detect WHO reference number: PQDx
WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT Product: Alere q HIV-1/2 Detect WHO reference number: PQDx 0226-032-00 Alere q HIV-1/2 Detect with product codes 270110050, 270110010 and 270300001,
More informationCardiac Bio-Marker Testing in Acute Coronary Syndromes
Cardiac Bio-Marker Testing in Acute Coronary Syndromes Dr. Zohair Alaseri, MD FRCPc, Emergency Medicine FRCPc, Critical Care Medicine Intensivest and Emergency Medicine Consultant Chairman, Department
More informationHM5. Hematology Analyzer BETTER. ACTUALLY.
HM5 Hematology Analyzer BETTER. ACTUALLY. Advanced Hematology Five-Part Differential The VetScan HM5 is a fully automated five-part differential hematology analyzer displaying a comprehensive 24-parameter
More informationHuman HIV (1+2) antigen&antibody ELISA Kit
Human HIV (1+2) antigen&antibody ELISA Kit Catalog Number. CSB-E18042h For the qualitative determination of human HIV (1+2) antibody and P24 antigen concentrations in serum, plasma. This package insert
More informationMorinaga Mouse C-peptide ELISA Kit
Morinaga Mouse C-peptide ELISA Kit For the quantitative determination of C-peptide in mouse serum, plasma, and fluid 96wells For Laboratory Use Only, not for use in diagnostic procedure Please read full
More informationDraft Report WHO evaluation of HIV 1/2 STAT-PAK (Chembio Diagnostic Systems Inc)
Date: 6 January 2012 Draft Report WHO evaluation of HIV 1/2 STAT-PAK (Chembio Diagnostic Systems Inc) WHO Collaborating Centre for HIV/AIDS Diagnostic and Laboratory Support Department of Clinical Sciences
More informationGSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard
GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full
More informationThermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything
Thermo Scientific Manual Pipetting Systems you can handle anything Leader in Pipetting Technology Since the introduction of the first variable volume micropipette in 1971, more than four million Thermo
More informationcobas u 601 urine analyzer Providing precise and secure test results
Providing precise and secure test results 1 of 6 Providing precise and secure test results cobas u 601 urine analyzer is a modular, analytical system platform for urine strip testing and features a fully
More informationRat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN
YK050 Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC. 2480-1 AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN 418-0011 Contents Introduction 2 Characteristics 3 Composition 4 Method 5-6 Notes
More information