LOWERING THE PROFILE RAISING THE BAR

Size: px
Start display at page:

Download "LOWERING THE PROFILE RAISING THE BAR"

Transcription

1 LOWERING THE PROFILE RAISING THE BAR

2 INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft material technology to treat a wide range of AAA anatomies. Access Low profile sheath for smooth tracking and delivery Control Highly predictable and accurate deployment Seal STRATA TM multilayer eptfe graft material for strength and conformability 17 F Hydrophilic Introducer Sheath Precise Deployment Dial

3 STRATA multilayer eptfe provides both strength and seal. Redefining eptfe Graft Performance Highly conformable eptfe maximizes wall contact. Anatomical Fixation Provides device stability and preserves the bifurcation for future endovascular procedures.

4 ONE SHEATH FOR ALL SIZES. AFX is the only EVAR system that utilizes a single low profile 17 F introducer sheath with a dilator to gain access in a wide range of AAA patients. AFX Delivery System Low profile introducer sheath provides unparalled access to treat more patients Hydrophilic coating for smooth delivery Sheath-dilator system provides exceptional pushability and tracking in tortuous vessels EVAR DEVICE ACCESS Ipsilateral Endologix AFX Medtronic Endurant TM * Cook Zenith Flex Gore Excluder C3 Aortic Neck N/A 17 F 18 F 20 F 18 F 20 F 22 F 18 F Introducer Size 20 F N/A Contralateral Endologix AFX Medtronic Endurant* Cook Zenith Flex Gore Excluder C3 Introducer Size 9 F FDA Approved F F F Percutaneous Indication No No No *The Endurant System does not use an introducer sheath. The device access shown corresponds to the Endurant outside diameter.

5 PREDICTABLE, CONSISTENT AND ACCURATE DEPLOYMENT. The AFX delivery system provides the predictability and control to navigate a wide range of anatomies and precisely deploy the device. Accurate and quick deployment with the control dial No gate cannulation required

6 PROVEN CLINICAL PERFORMANCE OF ANATOMICAL FIXATION. Clinical Trial Results from Three Prospective Multicenter Studies Migration...0% Aneurysm rupture...0% Conversion to open repair...0% Stent fracture...0% Aneurysm related mortality...0% Gate cannulation time...0 minutes Patient Profiles 1 N =157 Mean AAA diameter (cm): 5.6 ± 0.9 Mean proximal neck diameter : 29 ± 4 Prevalence of PAD 27% Hostile Neck Anatomies Short (<15 mm) 14% Severe Thrombus (>3 mm over >60% of circumference) 2 32% Reverse Taper (>2 mm over first 15 mm) 2 64% Any of the 3 Anatomies 83% % Patients Low Rate of EVAR Limb Interventions Patients Requiring Adjunctive Stenting and Interventions (reported through late follow-up) % 3.3% 2.8% 1.7% 1.2% 0 Endurant Medtronic US PMA 3 Talent Medtronic van Marrewijk Zenith Cook Greenberg Excluder Gore van Marrewijk Powerlink Endologix Carpenter Carpenter JP et al. Contemporary results of endovascular repair of abdominal aortic aneurysms: effects of anatomical fixation on outcomes. J Endovas Ther. 2010; 17(2): Data on file. 3. P100021: FDA summary of safety and effectiveness data 4. van Marrewijk CJ et. al. Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: how do stent-grafts compare? J Endovasc Ther 2005;12: Greenberg RK et. al. Zenith abdominal aortic aneurysm endovascular graft. J Vasc Surg 2008;48:1-9

7 AFX TM SYSTEM SPECIFICATIONS Bifurcated Unibody Devices B A / I Aortic Extensions A / C 95 - O20 Bifurcated Aortic Dimensions Main Body Main Body Iliac Dimensions Limb Bifurcated Stent Graft Limb Bifurcated Aortic Dimensions Iliac Dimensions B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I B A / I Aortic Dimensions Proximal Distal Covered Open * *Not present on Suprarenal Aortic Extension infrarenal extensions Proximal Aortic Dimensions Distal Covered Open A / C 95 - O 20 A / C 75 - O 20 A / C 55 - O 20 A / C 95 - O 20 A / C 55 - O 20 A / C 75 - O 20 A / C 80 - O 20 A / C O 20 Infrarenal Aortic Extension Aortic Dimensions Proximal Distal Covered A / C 55 A / C 75 A / C 95 A / C 55 A / C 75 A / C 95 A / C 80 A / C 100 Flexible Limb Extension Iliac Dimensions Proximal Distal Covered Design I / C 55 F I / C 70 F I / C 88 F I / C 55 F Limb Extensions I S / C 88 F Iliac Dimensions Shape* * Only Proximal present in shaped extensions S = Stepped F = Flared Distal Covered Flexible* * Only present on flexible limb extensions Limb Extension with Spine Proximal Iliac Dimensions Shape Distal Covered I / C 55 I / C 88 I / C 55 I S / C 55 I F / C 65 I S / C 65 Refer to the Instructions For Use for complete and specific prescribing information and all warnings, precautions, and adverse events. Rx only.

8 11 Studebaker Customer Service Irvine, CA Tel Tel Fax AFX and Strata are trademarks of Endologix, Inc. All other trademarks are the property of their respective owners Endologix, Inc. All rights reserved. MM0191 Rev 02

A New EVAR Device for Infrarenal AAAs

A New EVAR Device for Infrarenal AAAs A New EVAR Device for Infrarenal AAAs Peter Nelson, MD, MS Assistant Professor of Surgery MM0203 Rev. 01 Current U.S. EVAR Devices Anatomical Fixation Proximal Fixation Powerlink - Endologix Excluder WL

More information

Talent Abdominal Stent Graft

Talent Abdominal Stent Graft Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck

More information

Hostile Proximal Neck: A New Conformable EVAR Device

Hostile Proximal Neck: A New Conformable EVAR Device Hostile Proximal Neck: A New Conformable EVAR Device Young-Guk Ko, M.D., Seoul, Korea Currently Available Devices for EVAR in Korea, 2018 Zenith Flex, Cook Endurant IIs, Medtronic INCRAFT, Cordis AFX2,

More information

Access More Patients. Customize Each Seal.

Access More Patients. Customize Each Seal. Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate

More information

Challenging anatomies demand versatility.

Challenging anatomies demand versatility. Challenging anatomies demand versatility. The Distinct Advantages of Separating Seal and Fixation ANATOMICAL FIXATION Unlike proximal fixation designs, the AFX bifurcated unibody endograft allows for natural

More information

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ History of the Powerlink System Design and Clinical Results Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ Powerlink System: Unibody-Bifurcated Design Long Main Body Low-Porosity Proprietary eptfe

More information

FROM THE EVERYDAY TO THE EXTRAORDINARY

FROM THE EVERYDAY TO THE EXTRAORDINARY FROM THE EVERYDAY TO THE EXTRAORDINARY Created with the collaboration of more than 250 physicians around the world, ENDURANT empowers you to create stronger outcomes for more patients, including those

More information

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction

More information

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Degeneration of the Neck Post Implementation - a New Era of AAA Stent Degeneration of the Neck Post Implementation - a New Era of AAA Stent New Mexico Heart Institute Albuquerque, New Mexico USA - Gore Current FDA-Approved EVAR Devices Sealing Mechanism Endologix Lombard

More information

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Ovation Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Disclosure Statement of Financial Interest Within the past 12 months, I or my spouse/partner have had a financial interest/arrangement

More information

Durable outcomes. Proven performance.

Durable outcomes. Proven performance. Durable outcomes. Proven performance. GORE EXCLUDER AAA Endoprosthesis GORE EXCLUDER Iliac Branch Endoprosthesis GORE EXCLUDER AAA Endoprosthesis The most-studied* EVAR stent graft designed for durable

More information

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System, Young-Guk Ko, M.D., Dangas G, J Am Coll Cardiol Intv 2012;5:1071 All-cause Mortality Dangas Severance G, J Am Coll Cardiovascular Cardiol Intv Hospital, 2012;5:1071 Yonsei University Health System Aneurysm-related

More information

Considerations for a Durable Repair

Considerations for a Durable Repair Considerations for a Durable Repair Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany Disclosures William Cook

More information

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm LINC 2019 Leipzig, Germany Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm Deokbi Hwang, Sujin Park, Hyung-Kee Kim, Seung Huh Division

More information

2015 Clinical Update Endovascular Systems for AAA Repair

2015 Clinical Update Endovascular Systems for AAA Repair Endovascular Systems for AAA Repair 2 Musick Irvine, CA 92618 Tel 949.595.7200 Fax 949.612.1893 www.endologix.com TABLE OF CONTENTS Section Page ABSTRACT... 3 READER S GUIDE... 4 SECTION 1: US PIVOTAL

More information

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks Optimizing Accuracy of Aortic Stent Grafts in Short Necks Venkatesh Ramaiah, MD, FACS Medical Director Arizona Heart Hospital Director Peripheral Vascular and Endovascular Research Arizona Heart Institute

More information

TriVascular Ovation Prime Abdominal Stent Graft System

TriVascular Ovation Prime Abdominal Stent Graft System TriVascular Ovation Prime Abdominal Stent Graft System Science of the Seal O-Ring Sealing Technology O-Ring Sealing in Proven Engineering Solutions O-rings are designed to seal by blocking the flow of

More information

My personal experience with INCRAFT in standard and challenging cases

My personal experience with INCRAFT in standard and challenging cases My personal experience with INCRAFT in standard and challenging cases G Pratesi, MD Vascular Surgery University of Rome Tor Vergata giovanni.pratesi@uniroma2.it Disclosure Speaker name: Giovanni Pratesi,

More information

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Endovascular Repair o Abdominal Aortic Aneurysms Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Disclosure Nothing to disclose. 2 Mr. X AAA Mr. X. Is a 70 year old male who presented to

More information

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The evolution of AORFIX AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The confident choice for the right angles AORFIX the only AAA stent graft approved for all angulations from 0 90,

More information

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Current Status of Abdominal Aortic Stent Grafts John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Autumn Greetings Disclosure Statement of Financial Interest Within

More information

Technology. The introduction of endovascular aortic repair. cover story

Technology. The introduction of endovascular aortic repair. cover story Infrarenal EVAR Technology Review Steady evolution in device design and delivery has expanded endovascular repair to more patients, but further advancements are integral to this technology s future. By

More information

Durability of The Endurant Stent-Graft through 5 Years

Durability of The Endurant Stent-Graft through 5 Years Durability of The Endurant Stent-Graft through 5 Years Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh School

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology

More information

Abdominal and thoracic aneurysm repair

Abdominal and thoracic aneurysm repair Abdominal and thoracic aneurysm repair William A. Gray MD Director, Endovascular Intervention Cardiovascular Research Foundation Columbia University Medical Center Abdominal Aortic Aneurysm Endografts

More information

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital The Ventana Off-the-Shelf Graft for Pararenal AAA Andrew Holden Associate Professor of Radiology Auckland Hospital Disclosures Andrew Holden, MBChB, FRANZCR Investigator in Nellix and Ventana Trials Clinical

More information

Right Choice for Right Angles

Right Choice for Right Angles Right Choice for Right Angles The Anatomy of Technology Aorfix gives you technology that conforms to patient anatomy, optimising both procedure and post-operative performance. Fishmouth for optimum neck

More information

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Interventional Cardiologist/Endovascular Specialist Bradenton Cardiology Center Bradenton, FL, USA Disclosures

More information

Nellix Endovascular System: Clinical Outcomes and Device Overview

Nellix Endovascular System: Clinical Outcomes and Device Overview Nellix Endovascular System: Clinical Outcomes and Device Overview Jeffrey P. Carpenter, MD Professor and Chief, Department of Surgery CAUTION: Investigational device. This product is under clinical investigation

More information

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients The Ovation System is approved to treat infrarenal abdominal aortic aneurysms and is not

More information

NASDAQ: ELGX December Innovation that Empowers

NASDAQ: ELGX  December Innovation that Empowers NASDAQ: ELGX www.endologix.com December 2014 Innovation that Empowers Safe Harbor This presentation contains forward-looking statements within the meaning of the Private Securities Litigation Reform Act

More information

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully supported by self-expanding z-stents H&L-B

More information

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Robert Y. Rhee, MD Chief, Vascular and Endovascular Surgery Director, Aortic Center Maimonides Medical Center Brooklyn,

More information

Anatomical challenges in EVAR

Anatomical challenges in EVAR Anatomical challenges in EVAR M.H. EL DESSOKI, MD,FRCS PROFESSOR OF VASCULAR SURGERY CAIRO UNIVERSITY Disclosure Speaker name:... I have the following potential conflicts of interest to report: Consulting

More information

Improving Endograft Durability with EndoAnchors

Improving Endograft Durability with EndoAnchors Improving Endograft Durability with EndoAnchors William D. Jordan, Jr., M.D. John E. Skandalakis Chair in Surgery Professor and Chief Division of Vascular Surgery and Endovascular Therapy Emory University

More information

Evolution of gender-related differences in outcome of EVAR

Evolution of gender-related differences in outcome of EVAR Evolution of gender-related differences in outcome of EVAR Erik Debing Department of Vascular Surgery University Hospital Brussels Disclosure Speaker name: ERIK DEBING... I have the following potential

More information

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery Current Status of EVAR for Infrarenal AAA 31 st Annual Florida Vascular Society PENN Surgery No Disclosures Stent Grafts Design Related Differences What really matters? Modular Unibody Supported Unsupported

More information

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous

More information

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts

More information

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Robert F. Cuff, MD FACS SHMG Vascular Surgery Robert F. Cuff, MD FACS SHMG Vascular Surgery Objectives To become familiar with the commercially available fenestrated EVAR graft Discuss techniques to increase success Review available data to determine

More information

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs How to select FEVAR versus EVAR + endoanchors in short-necked AAAs Jean-Paul P.M. de Vries, Richte C.L. Schuurmann St. Antonius Hospital Nieuwegein, The Netherlands 21st Critical Issues Congress Nuernberg,

More information

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY Patrice Mwipatayi FCS (SA), MMed, FRACS Professor of Vascular surgery Royal Perth Hospital, University of Western Australia, Perth, WA Co-Authors:

More information

Abdominal Aortic Aneurysm 가천대길병원 이상준

Abdominal Aortic Aneurysm 가천대길병원 이상준 Abdominal Aortic Aneurysm 가천대길병원 이상준 1 Definition Diameter of the aorta 1.5 times greater than normal. Most are infrarenal, and a significant number extend down into one or both iliac arteries Abdominal

More information

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT Device description Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21181-EN-F Modular design The two-piece modular system allows the physician to customize a graft system to fit each

More information

EVAR replaced standard repair in most cases. Why?

EVAR replaced standard repair in most cases. Why? EVAR replaced standard repair in most cases. Why? Initial major steps in endograft evolution Papazoglou O. Konstantinos M.D. The story of a major breakthrough in vascular surgery 1991 Parodi introduces

More information

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Disclosures Speaker name: Dittmar Böckler I have the following potential conflicts

More information

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands Treatment options of late failures of EVAS Michel Reijnen Rijnstate Arnhem The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts of interest to report: Consulting

More information

Endologix PowerWeb System EPW?

Endologix PowerWeb System EPW? 13 579 583 2004 Endologix PowerWeb System EPW? Endologix PowerWeb System EPW (AAA) 1993 7 2003 11 AAA 176 155 21 52 897240 120mm 53.5mm EPWEPW 1 2 proximal neck PN 15mm 3 PN 23mm 4 distal neck DN 15mm

More information

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Nilo J Mosquera, MD. Head of Department Angiology and Vascular Surgery. CHUO Hospital. Ourense. Spain Disclosure

More information

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS All-In-One Iliac Branch System PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS Exclusively Designed for Use in The GORE EXCLUDER Iliac Branch designed for the iliac branch, built from the same

More information

Technique and Tips for Complicated AAA Cases with Stent Graft

Technique and Tips for Complicated AAA Cases with Stent Graft Technique and Tips for Complicated AAA Cases with Stent Graft Seung-Woon Rha, MD, PhD FACC, FAHA, FESC, FSCAI, FAPSIC Cardiovascular Center, Korea University Guro Hospital Mar 15, 2018 LINC AP 2018 Endoleak;

More information

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Tim Resch MD Vascular Center Skane University Hospital Conflicts of Interest COOK Medical - Consulting, Speakers Bureau, IP, Research support Medtronic

More information

Indications for use. Contraindications within the United States

Indications for use. Contraindications within the United States Indications for use Indications within the United States The GORE TAG Thoracic Endoprosthesis is intended for endovascular repair of all lesions of the descending thoracic aorta, including: Isolated lesions

More information

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

What's on the Horizon for AAA: Unilateral & Percutaneous, UP-EVAR System Zoran Rancic M.D., Ph.D. What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D. Clinic for Cardiovascular Surgery University Hospital Zurich DISCLOSURES COMMON SITUATIONS FOR UNILATERAL

More information

14F OD Ovation Abdominal Stent Graft System

14F OD Ovation Abdominal Stent Graft System 14F OD Ovation Abdominal Stent Graft System 2 Year Results from the European Study Dierk Scheinert, MD Center for Vascular Medicine Angiology and Vascular Surgery Park Hospital Leipzig, Germany Disclosure

More information

Ancillary Components with Z-Trak Introduction System

Ancillary Components with Z-Trak Introduction System Ancillary Components with Z-Trak Introduction System Zenith Flex AAA Endovascular Graft Ancillary Components Converter Converters can be used to convert a bifurcated graft into an aortouniiliac graft if

More information

TRAINING DOCUMENT, FOR INTERNAL USE ONLY. Pre-case Planning

TRAINING DOCUMENT, FOR INTERNAL USE ONLY. Pre-case Planning TRINING DOCUMENT, FOR INTERNL USE ONLY Pre-case Planning Imaging Specifications CONTRST ENHNCED CT-SCN CT angiography date should be within 3 months of implant date CT slices thickness not exceeding 3

More information

Vascular V12. Covered Stent. The New Standard of Care

Vascular V12. Covered Stent. The New Standard of Care Vascular V12 Covered Stent The New Standard of Care Innovation Novel Thermo-Conformable Covered Stent 316L stainless steel stent completely encapsulated in a proprietary one piece eptfe film cast covering

More information

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster Disclosure Speaker name:...michel Bosiers... I have the following potential conflicts of interest to report: Consulting Employment

More information

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Alan R. Wladis, MD, FACS, David Varnagy, MD, FACS, Manuel R. Perez-Izquierdo, MD, Mark Ranson, MD FACS, Delos Clift, MD FACS, Rebecca

More information

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED.

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED. EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED. A/Prof. B. Patrice Mwipatayi MD, MMed (Surg), MClinEd (Melb), FCS, FRACS Department of Vascular Surgery, Royal

More information

INCRAFT system: Update from the Pivotal INSPIRATION Study

INCRAFT system: Update from the Pivotal INSPIRATION Study INCRAFT system: Update from the Pivotal INSPIRATION Study Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh

More information

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016.

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016. AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA JORGE FERNÁNDEZ NOYA ANGIOLOGY AND VASCULAR SURGERY DEPARTMENT UNIVERSITARY CLINICAL HOSPITAL SANTIAGO DE COMPOSTELA 2 nd -3 rd June 2016. 1888 ENDOANEURYSMORRHAPHY

More information

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms J ENDOVASC THER 173 TECHNICAL NOTE Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms Renato Mertens, MD; Michel Bergoeing, MD; Leopoldo Mariné, MD; Francisco

More information

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Jean-Paul P.M. de Vries Head Department of Surgery, University Medical Centre Groningen The

More information

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University,

More information

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair 583 Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair Frank R. Arko, MD; W. Anthony Lee, MD; Bradley B. Hill, MD; Paul Cipriano,

More information

FLEXIBLE, BALOON EXPANDABLE

FLEXIBLE, BALOON EXPANDABLE EARLY RESULTS OF A CLINICAL TRIAL OF FLEXIBLE, BALOON EXPANDABLE COVERED STENT GRAFT IN ILIAC OCCLUSIVE DISEASE Chris LeCroy Coastal Vascular and Interventional Pensacola, Florida Clinical Trial WL GORE

More information

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Michel MPJ Reijnen, MD, PhD Department of Vascular Surgery, Rijnstate Hospital

More information

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Eric LG Verhoeven,MD, PhD, A. Katsargyris, MD Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany

More information

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution Patient selection in Hostile Necks and how to prevent endoleaks a word of caution P M Kasprzak, K. Pfister Department of Vascular Surgery Endovascular Surgery University Hospital Regensburg, Germany Conflict

More information

11/20/2014. Disclosures. Kissing Balloons and Stents. Treatment of Aortoiliac Occlusive Disease. Data on Patency of Kissing Stents.

11/20/2014. Disclosures. Kissing Balloons and Stents. Treatment of Aortoiliac Occlusive Disease. Data on Patency of Kissing Stents. RESULTS FROM A MULTI-CENTER, RETROSPECTIVE REVIEW OF THE AFX ENDOGRAFT FOR USE IN AORTOILIAC OCCLUSIVE DISEASE Disclosures Cook Endologix Medtronic Thomas Maldonado, MD Associate Professor Department of

More information

Hostile Neck During EVAR, The Role Of Endoanchores

Hostile Neck During EVAR, The Role Of Endoanchores Hostile Neck During EVAR, The Role Of Endoanchores Samer Koussayer, MD, FACS, RVT Prof, Al Faisal University Section Head and consultant Vascular & Endovascular Surgery Division King Faisal Specialist

More information

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Cook Medical Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full-thickness,

More information

Less Invasive EVAR Transitioning to a Fast-Track Protocol

Less Invasive EVAR Transitioning to a Fast-Track Protocol Less Invasive EVAR Transitioning to a Fast-Track Protocol Mario Lachat, MD University of Zurich Department of Cardiovascular Surgery Switzerland LINC 2015 1 Disclosure Speaker name: Mario Lachat, MD I

More information

Vascular Specialist International

Vascular Specialist International Vascular Specialist International Vol. 33, No. 1, March 2017 pissn 2288-7970 eissn 2288-7989 Initial Clinical Experience with the Endologix AFX Unibody Stent Graft System for Treating Patients with Abdominal

More information

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR The Auckland Experience with the Nellix EVAS System Andrew Holden, MBChB, FRANZCR Disclosure Speaker name: Associate Professor Andrew Holden I have the following potential conflicts of interest to report:

More information

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? Disclosures Speaker name: Dittmar Böckler

More information

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Taming The Aorta David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Faculty Disclosure Consulting: Endologix, Cook 1 Objectives Review the

More information

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues Disclosures is it time to discuss individualized follow-up schemes based on preoperative anatomy and high quality completion angiography? Consultant / Speaker / Proctor Cook Cordis Medtronic Invatec W.L.

More information

From 1996 to 1999, a total of 1,193 patients with

From 1996 to 1999, a total of 1,193 patients with THE ANEURX CLINICAL TRIAL AT 8 YEARS Lessons learned following the US AneuRx clinical trial from 1996 to 2004. BY CHRISTOPHER K. ZARINS, MD From 1996 to 1999, a total of 1,193 patients with infrarenal

More information

Ovation 4-Year Results Pivotal Study to Evaluate the Safety and Effectiveness of the Ovation System

Ovation 4-Year Results Pivotal Study to Evaluate the Safety and Effectiveness of the Ovation System Ovation 4-Year Results Pivotal Study to Evaluate the Safety and Effectiveness of the Ovation System Vascular Health Partners Glens Falls, New York Disclosure Speaker name: I have the following potential

More information

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Saritphat Orrapin MD FRCS (Thailand), Thoetphum Benyakorn, Tunyarat

More information

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM Pure performance and quality: Stent graft systems by JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development

More information

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium Disclosure Speaker name: Isabelle Van Herzeele I have the following potential

More information

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim Endovascular Procedures for Isolated Common Iliac and Internal Iliac Aneurysm Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University

More information

Proven Performance Through Innovative Design *

Proven Performance Through Innovative Design * Proven Performance Through Innovative Design * Deliver Our Next Generation AV Covered Stent Results The COVERA Vascular Covered Stent builds upon proven technologies from the category leader in AV Access.

More information

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Robert Fisher Royal Liverpool University Hospital, UK Liverpool Vascular and Endovascular Service Introduction Late

More information

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX 2018 A BIT OF HISTORY First use of F-EVAR : 1990s Park et al. J Vasc Interv Radiol. 1996;7:819-823. Faruqi et al. J Endovasc Surg.

More information

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER 2018 Abstract This annual clinical update provides a review of the ongoing experience with the GORE EXCLUDER AAA Endoprosthesis used in the

More information

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY Disclosures Speaker Bureau: - Medtronic - Cook Medical - Bolton

More information

12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms

12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms 11 12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms Ziheng Wu 1, Lefeng Qu 2, Dieter Raithel 3 and Konstantinos Xiromeritis³ 1 Department of

More information

NEW INNOVATIONS IN ENDOLEAK MANAGEMENT

NEW INNOVATIONS IN ENDOLEAK MANAGEMENT DISCLOSURES NEW INNOVATIONS IN ENDOLEAK MANAGEMENT Kelley HodgkissHarlow, MD, RPVI, FACS Vascular and Endovascular Surgery Kaiser Permanente, San Diego Nothing to disclose GOALS BACKGROUND Background Surveillance

More information

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece Obesity, Scaring, Access in EVAR Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece Obesity Decreased radiolucency (visibility) Max weight load < 160

More information

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18 When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs JEAN-PAUL P.M. DE VRIES, DIRECTOR OF VASCULAR SURGERY ST.ANTONIUS HOSPITAL NIEUWEGEIN, THE NETHERLANDS. LINC ASIA-PACIFIC HongKong,

More information

Aortic stents, types, selection, tricks in deployment.

Aortic stents, types, selection, tricks in deployment. Aortic stents, types, selection, tricks in deployment. Hamdy Soliman.M.D,FSCAI Consultant of Cardiology&Head of Endovascular Unit National Heart Institute Endovascular Treatment of Thoracic Aortic Aneurysms

More information

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE)

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE) NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE) Review of TA167; Endovascular stent-grafts for abdominal aortic aneurysms Final recommendation post consultation The guidance should

More information

Endovascular options of treating iliac aneurysms

Endovascular options of treating iliac aneurysms Endovascular options of treating iliac aneurysms Marek Majewski Department of Vascular Surgery of P. Desgranges Henri Mondor Hospital University Paris XII Créteil, France Common Iliac Artery Aneurysms

More information

How to do AAA EVAR: Tips and Tricks

How to do AAA EVAR: Tips and Tricks How to do AAA EVAR: Tips and Tricks June 14, 2007 Jon S. Matsumura, MD Associate Professor of Surgery Division of Vascular Surgery Northwestern University Medical School Disclosure Information Jon Matsumura,

More information