CORESTA Recommended Method No. 84

Size: px
Start display at page:

Download "CORESTA Recommended Method No. 84"

Transcription

1 Cooperation Centre for Scientific Research Relative to Tobacco E-Vapour Sub-Group CORESTA Recommended Method No. 84 DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS June 2017

2 CORESTA RECOMMENDED METHOD Nº 84 Title: DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS Status: Valid Note: Document history: Date of review Information March 2017 Version 1 June 2017 Version 2 - Re-edition of formula p. 9 CRM No. 84 June /11

3 CORESTA RECOMMENDED METHOD N 84 DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS (March 2017) 0. INTRODUCTION In 2015, the CORESTA E-Cigarette Task Force (changed to E-Vapour Sub-Group in 2016) conducted a collaborative study for the determination of glycerin, propylene glycol, nicotine, and water using gas chromatography. Nineteen laboratories participated in the study. The method specified in this study was shown to be appropriate for the analytes of interest for aerosol from e-vapour products. The repeatability and reproducibility values of this method have been assessed according to ISO :1994 recommendations and are included. 1. FIELD OF APPLICATION This method is applicable to analysis of glycerin, propylene glycol, nicotine, and water in trapped e-cigarette aerosol. 2. NORMATIVE REFERENCES CORESTA Recommended Method N : Routine analytical machine for e-cigarette aerosol generation and collection definitions and standard conditions. 3. PRINCIPLE Aerosol is generated and collected from electronic cigarettes by a standard procedure. The collected matter is dissolved in a solvent and the glycerin, propylene glycol (PG), water, and nicotine content of this solution are determined by gas chromatography. Aerosol collected mass may be determined gravimetrically. Results are expressed as the weight of analyte collected per device, per weight of collected aerosol, per puff, or per puff set as warranted. 4. APPARATUS 4.1. A standard aerosol collection system and trapping devices (i.e. filter pads) complying with CORESTA Recommended Method N Typical laboratory glassware such as volumetric flasks and extraction vessels. CRM No. 84 June /11

4 4.3. Mechanical shaker Analytical balance, suitable for measuring to the nearest 0,1 mg A gas chromatograph (GC) equipped with a flame ionization detector (FID) and data collection for glycerin, propylene glycol, or nicotine analysis A gas chromatograph (GC) equipped with a thermal conductivity detector (TCD) and data collection for water analysis Gas chromatography column(s), capillary or packed, capable of distinct separation of the peaks for the solvent, internal standard, analytes of interest from each other and other components of the sample extract. Typically a DB-ALC1 (30 m 0,32 mm 1,8 µm) may be used Gloves (powder-free) and any other personal protective equipment deemed appropriate by the testing laboratory. 5. REAGENTS 5.1. Propan-2-ol (analytical grade, maximum water content 1,0 mg/ml) Internal standard(s) for water: 1,4-butanediol, or ethanol, or other appropriate internal standards which have been demonstrated not to co-elute with other peaks and have been found to be consistent for peak area (minimum purity 99 %). A typical concentration for internal standard is 0,2 mg/ml Internal standard(s) for other analytes: n-heptadecane, or quinaldine, n-octadecane, or other appropriate internal standards which have been demonstrated not to co-elute with other peaks and have been found to be consistent for peak area (minimum purity 99 %). A typical concentration for internal standard is 1 mg/ml Gases: hydrogen, nitrogen, and helium and compressed air as necessary for operation of the GC Glycerin (1,2,3-propanetriol, CAS ); propylene glycol (1,2-propanediol, CAS ); (-)-nicotine (CAS ); (minimum purity 99 %) for preparation of standard solutions. Protect from moisture, air, and light as indicated by vendor Water: Type I, or equivalent, distilled or deionized water, minimum resistivity of 18,2 MΩ-cm at 25 C, and free from contamination by analytes of interest. For testing that includes the analysis of water, the bulk solvent (0) container should be fitted with a water trap and all solutions should be kept sealed. Glassware and septa for vials should be stored in a desiccator until use. CRM No. 84 June /11

5 6. CALIBRATION STANDARDS Dissolve glycerin, propylene glycol, water, and nicotine in the solvent to produce a series of at least five calibration solutions including blanks, as warranted, whose concentrations cover the range expected to be found in the samples. A typical range of calibration standards for each analyte is listed in the table below: Table 1 - Calibration standards Analyte Glycerin 0,05 2,0 Propylene glycol 0,05 2,0 Typical range (mg/ml) Water 0 and 0,5 20 Nicotine 0,05 2,0 Note that a blank standard is needed for water and may be warranted for some or all of the other analytes depending on the anticipated concentration range of the samples. Store calibration standards at (4 ± 2) C and protect from light. 7. PROCEDURES 7.1. Gas chromatography (Glycerin, PG, nicotine) Set up and operate the gas chromatograph and equipment according to the manufacturer s instructions. Ensure that peaks of interest are well resolved. Operating conditions, including column type, should be optimized for analyte separation and sensitivity. Typical operating conditions are as follows: Table 2 - Example of operating conditions for gas chromatography (Glycerin, PG, nicotine) Column Carrier Gas Injection Temperature 250 C DB-ALC1 (30 m 0,32 mm 1,8 µm) Helium, 3 ml/min Injection mode Split, 25:1 Injection volume 1 µl Oven temperature Detector Detector Temperature 275 C 90 C (1 min), 15 C/min to 120 C, 40 C/min to 280 C (2 min) Flame Ionization 7.2. Gas chromatography (water) Set up and operate the gas chromatograph and equipment according to the manufacturer s instructions. CRM No. 84 June /11

6 Ensure that peaks of interest are well resolved. Operating conditions, including column type, should be optimized for analyte separation and sensitivity. Typical operating conditions are as follows: Table 3 - Example of operating conditions for gas chromatography (water) Column Carrier Gas DB-ALC1 (30 m 0,32 mm 1,8 µm) Helium, 1.5 ml/min Injection Temperature 225 C Injection mode Split, 10:1 Injection volume 2 µl Oven temperature Detector 90 C (1 min), 15 C/min to 120 C, 40 C/min to 280 C (2 min) Thermal Conductivity Detector Temperature 250 C 7.3. Instrument Calibration of the gas chromatograph(s) Inject aliquots of the standard solutions into the gas chromatograph. Record the peak areas or heights of the analytes and the internal standard. Calculate the ratio of the analyte peak to the internal standard peak from the peak area (or height) data for each of the calibration solutions. Determine the slope (m) and intercept (b) based on linear regression (y = mx +b) for each of the analytes. If the coefficient of determination, R 2, is less than 0,995, calibration should be repeated. The signal (peak area or height) obtained for all test portions must fall within the working range of the calibration curve. If test samples are outside of the working calibration range, the range may be extended if the suitability of the calibration is verified and maintained. Alternatively, samples may be diluted with the solvent (5.4) as appropriate Filter pad handling Filter pads should be stored in the target atmosphere of the test conditions for a minimum of 24 hours prior to determination of pre-testing weights. For all operations, the operator shall prevent contamination from the fingers by wearing gloves of a suitable material (4.8). Between operations, a filter pad holder cap, if available, may be installed to prevent water loss or uptake. Filter pads should be processed as quickly after collection as is feasible to prevent uptake or loss of water Aerosol collection and sample preparation Using CORESTA Recommended Method N 81 set up the aerosol collection system and collect the aerosol onto glass fiber filter pads. Collection parameters such as number of puffs or number of puff sets are dependent on study design. In any case, it should be ensured that the capacity of the filter pads for aerosol is not exceeded. In addition, after aerosol collection, remove holder assemblies from the collection system and process for determination of aerosol mass as necessary (7.6). CRM No. 84 June /11

7 For each filter pad, open the holder and remove filter pad with forceps. Fold the pad twice with the aerosol side toward the inside of the folds, being careful to handle only the edge of the filter pad. Wipe the inside of the filter holder front with two separate quarters of an unused conditioned filter disc and add these to the flask to collect any residual aerosol. Alternatively, wipe the holder with the folded unused side of the filter pad. Transfer to a sample vessel for extraction. Extract the filter pads using a fixed volume of the solvent (5.4) of 20 ml for 44 mm pads or 50 ml for 92 mm pads and 30 min of agitation on a mechanical shaker. The volume of solvent may be adjusted to give analyte concentrations in the range of the calibration standards. The maximum storage time of the extracts is 48 hours under ambient conditions. The storage time may be extended if the stability of the extracts is verified. The extracts must be protected from light Simultaneous determination of Aerosol Collected Mass Optionally, aerosol collected mass (ACM) may be determined gravimetrically. Filter pads in their holder (with or without end caps) and without e-cigarette holders are weighed before and after aerosol collection prior to extraction for analyte analysis. Weights should be determined to the nearest 0,1 mg. Aerosol mass is calculated as: m ACM (mg) = m1 m 0 Where: m = mass 1 = after aerosol collection 0 = before aerosol collection Express the test results in mg/puff, mg/puff set, mg/total puffs or mg/per device as indicated by study design Simultaneous determination of e-cigarette mass loss Optionally, the mass loss of the device may be determined gravimetrically. The test article should be weighed prior to installation on the collection system. Subsequent frequency of mass determination should be as indicated by study design. For example, the test article may be reweighed between each pad set or may be reweighed after completion of the testing session. It is recommended that the mass before collection value be verified if there is any significant time delay between sequential collections (i.e. collection sets that span multiple work days). m ec (mg) = m 1 m 0 Where: m = mass ec = e-cigarette, device 1 = after aerosol collection 0 = before aerosol collection CRM No. 84 June /11

8 7.8. Blank Test for Water Due to the absorption of water by smoke traps and solvent, it is necessary to determine a value for a test blank. At least two (2) test blanks must be included with each collection run. Prepare test blanks by installing a filter pad in its holder as if preparing for aerosol collection. Place the test blanks in close proximity to the collection system during aerosol collection and extract and analyse them with the samples from the associated collection Simultaneous versus sequential analysis for water content The chromatographic methods described herein, or equivalent, may be used in conjunction with each other using two chromatographs or using a single chromatograph equipped with dual columns and dual detectors. A simultaneous automated analysis of water and of glycerin, PG, and nicotine may be achieved by using a GC system equipped with dual detectors in series or with a GC system with dual autosamplers, inlets, columns, and detectors operated in parallel. Example workflow scenarios are shown in the diagram below. When determining analytes from the same sample sequentially, the water determination should be performed first to prevent absorption of water by the sample affecting the final result. Workflow 1 (Simultaneous) Workflow 2 (Sequential) Workflow 3 (Parallel) Optional Determinations: Aerosol Mass, E-Cig Mass Loss Optional Determinations: Aerosol Mass, E-Cig Mass Loss Optional Determinations: Aerosol Mass, E-Cig Mass Loss Extraction of filter pads Extraction of filter pads Extraction of filter pads Single GC (Dual Column) GC-FID, GC-TCD GC-TCD Analysis for Water GC-TCD Analysis for Water GC-FID Analysis for glycerin/pg/nicotine GC-FID Analysis for glycerin/pg/nicotine CRM No. 84 June /11

9 7.10. Determination of analyte content for the samples Inject one or more aliquots of the sample extracts into the gas chromatograph(s) using the conditions described in sections 7.1 and or 7.2. Record the peak areas or heights of analytes and the internal standard(s). Calculate the mean value of the ratio of the peak area or height of analyte to that of the internal standard for the replicate injections. The amount of analyte is determined in mg/ml using an internal standard calibration method. Ensure that the values lie within the range of the standards prepared in section 6. For water analysis, subtract the average value of the test blank(s) associated with the collection from the value for each sample pad: Where: w= water s= sample b = test blank, average water (mg/ml) = w s w b For each analyte, express the test results in mg/mg ACM, mg/puff, mg/puff set, mg/total puffs or mg/per device as indicated by study design. Example calculations are given below: Where: N(mg mg ACM) = C V m ACM N = Nicotine C = the concentration obtained from the calibration curve (mg/ml) m ACM = mass of aerosol collected mass (mg) Vol = the volume of extraction solution added to the sample (20 ml) Where: N(mg puff) = C P V C = the concentration obtained from the calibration curve (mg/ml) P = number of puffs collected V = the volume of extraction solution added to the sample (20 ml) CRM No. 84 June /11

10 8. REPEATABILITY AND REPRODUCIBILITY Results listed in the tables below are based on the study 2015 Aerosol Collaborative Study: Major Constituents Proficiency Study conducted jointly between the E-Vapour Sub-Group (EVAP) and the Routine Analytical Chemistry Sub-Group (RAC) using four commercialvapour products. The average r&r values from these results are listed directly below. The individual results are listed on the following page. Note that due to the higher variability of e- cigarettes relative to cigarettes for yield of these analytes, proportioning to ACM may be a preferred manner of reporting in many cases. Therefore, r&r values are displayed as is and as proportioned to ACM. Table 4 - r&r values for Analytes mg ( as is ) Average of all samples ACM Nicotine PG Glycerin Water r (%) 33.85% 36.97% 36.03% 33.53% 31.35% R (%) 47.75% 46.27% 49.93% 46.40% 84.63% Table 5 - r&r values for Analytes proportioned to ACM Average of all samples Nicotine/ACM PG/ACM Glycerin/ACM Water/ACM r (%) 5.97% 5.55% 6.80% 23.98% R (%) 20.47% 9.90% 14.03% 65.33% Table 6 - r&r values for Analytes mg/total puffs collected as is Individual results for each sample Sample Code ACM Nicotine PG Glycerin Water Sample A Sample B Sample C Sample D r (%) 28.60% % 28.90% 28.40% R (%) 46.60% % 39.50% 78.80% r (%) 33.50% 36.00% 36.10% 32.60% 29.20% R (%) 56.70% 49.40% 57.10% 52.00% % r (%) 39.40% 40.50% 41.50% 39.10% 35.70% R (%) 47.20% 50.00% 47.40% 47.70% 71.20% r (%) 33.90% 34.40% 35.50% % R (%) 40.50% 39.40% 44.00% % Repeatability and reproducibility calculations were based on a test result being the average of four test items. Calculations were carried out using the robust algorithms in ISO ; -- = Not calculated. CRM No. 84 June /11

11 Table 7 - r&r values for Analytes proportioned to ACM Individual results for each sample Sample Code ACM Nicotine/ACM PG/ACM Glycerin/ACM Water/ACM Sample A Sample B Sample C Sample D r (%) 28.60% % 6.10% 22.00% R (%) 46.60% % 17.80% 64.70% r (%) 33.50% 5.20% 5.10% 6.10% 29.00% R (%) 56.70% 22.20% 9.60% 13.80% 81.50% r (%) 39.40% 6.50% 6.50% 8.20% 23.90% R (%) 47.20% 17.10% 10.20% 10.50% 62.10% r (%) 33.90% 6.20% 5.30% % R (%) 40.50% 22.10% 10.00% % Repeatability and reproducibility calculations were based on a test result being the average of four test items. Calculations were carried out using the robust algorithms in ISO ; -- = Not calculated. Similarly, to get a better assessment of the performance of the analytical methods independent of the variability of the devices, repeatability and reproducibility limits were calculated on Sample F, the liquid control sample. Those results are given in the following table. Table 8 - r&r values for Sample F, the liquid control sample Sample Code Nicotine PG Glycerin Water Sample F r (%) 4.37% 4.45% 6.07% 13.6% R (%) 14.8% 10.9% 20.7% 30.5% 9. TEST REPORT The test report shall give the analyte content of the sample as a mass fraction based on the collection parameters of the testing (i.e. per puff, per ACM, per total puffs, per device, etc.). The test report shall also mention all pertinent operating conditions not specified in this CORESTA Recommended Method as well as any circumstances that may have affected the result. CRM No. 84 June /11

CORESTA RECOMMENDED METHOD N 8

CORESTA RECOMMENDED METHOD N 8 CORESTA RECOMMENDED METHOD N 8 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS (August 1991) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

CORESTA RECOMMENDED METHOD NÄ 9

CORESTA RECOMMENDED METHOD NÄ 9 CORESTA RECOMMENDED METHOD NÄ 9 DETERMINATION OF NICOTINE IN CIGARETTE FILTERS BY GAS CHROMATOGRAPHIC ANALYSIS (April 2009) 0. INTRODUCTION In 2001 the CORESTA Routine Analytical Chemistry Sub-Group was

More information

CORESTA Recommended Method No. 78

CORESTA Recommended Method No. 78 Cooperation Centre for Scientific Research Relative to Tobacco Smoke Analytes Sub-Group CORESTA Recommended Method No. 78 DETERMINATION OF SELECTED PHENOLIC COMPOUNDS IN MAINSTREAM CIGARETTE SMOKE BY HPLC-FLD

More information

TNCO Testing procedures

TNCO Testing procedures TNCO Testing procedures Chris Proctor Pete Davis British American Tobacco Group R&D UK US FDA Center for Tobacco Products Scientific Workshop 30-31 July 2013 1 A. Describe the different extraction steps

More information

Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant

Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant October 2012 Korea Food & Drug Administration I. Introduction Due to the recent increased interest

More information

CORESTA Recommended Method No. 85

CORESTA Recommended Method No. 85 Cooperation Centre for Scientific Research Relative to Tobacco Routine Analytical Chemistry Sub-Group CORESTA Recommended Method No. 85 TOBACCO - DETERMINATION OF THE CONTENT OF TOTAL ALKALOIDS AS NICOTINE

More information

CORESTA Recommended Method No. 56

CORESTA Recommended Method No. 56 Cooperation Centre for Scientific esearch elative to Tobacco Tobacco and Tobacco Products Analytes Sub-Group COESTA ecommended Method No. 56 DETEMINATION OF WATE IN TOBACCO AND TOBACCO PODUCTS BY KAL FISCHE

More information

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) 1.0 SCOPE AND APPLICATION 1.1 The following compounds can be determined by this method: Compound Name

More information

The Chemical characterisation of E-device Aerosols

The Chemical characterisation of E-device Aerosols The Chemical characterisation of E-device Aerosols Stuart Martin & Chris Rawlinson CORESTA SSPT ST02 30 th September 2013 Group R&D, British American Tobacco, Southampton, UK Introduction BAT s initial

More information

CORESTA RECOMMENDED METHOD N 39

CORESTA RECOMMENDED METHOD N 39 CORESTA RECOMMENDED METHOD N 39 DETERMINATION OF THE PURITY OF NICOTINE AND NICOTINE SALTS BY GRAVIMETRIC ANALYSIS - TUNGSTOSILICIC ACID METHOD (November 1994) 0. INTRODUCTION Several methods for checking

More information

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017 E-Vapour (EVAP) Sub-Group 2017 Report Kitzbühel, Austria October 10, 2017 History Evolution o 2014, formation of E-cigarette TF o 2016, TF activities completed; formation of E-vapor product SG 2 E-Vapour

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8454 Third edition 2007-06-01 Cigarettes Determination of carbon monoxide in the vapour phase of cigarette smoke NDIR method Cigarettes Dosage du monoxyde de carbone dans la

More information

2.1 Determination of Ethanol (Ethyl Alcohol)

2.1 Determination of Ethanol (Ethyl Alcohol) Document #: 4981 Page 1 of 13 2.1 Determination of Ethanol (Ethyl Alcohol) 2.1.1 General Description of Method A procedure utilizing a gas chromatograph (GC) for the determination of ethanol. Two quantitative

More information

Fig.1. Denatonium benzoate (DB) chemical structure

Fig.1. Denatonium benzoate (DB) chemical structure ILIADE code 280 CLEN Method Determination of Denatonium Benzoate in Alcoholic Products by HPLC-UV 1 Scope The purpose of this method is verification of fulfilment of the legislative requirements on denatured

More information

HUMAN LIVER SLICE EXPERIMENT 1 Effects of Propylene Glycol on Ethylene Glycol Metabolism

HUMAN LIVER SLICE EXPERIMENT 1 Effects of Propylene Glycol on Ethylene Glycol Metabolism HUMAN LIVER SLICE EXPERIMENT 1 Effects of Propylene Glycol on Ethylene Glycol Metabolism Determination of Ethylene Glycol, Propylene Glycol, Oxalic Acid and Glycolic Acid BioReliance Study Number Testing

More information

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No. Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are

More information

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph Application Note Food Rapid Analysis of 37 FAMEs with the Agilent 88 Gas Chromatograph Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd., Shanghai 131 P. R. China Abstract An Agilent 88 GC

More information

CORESTA Recommended Method No. 74

CORESTA Recommended Method No. 74 Cooperation Centre for Scientific Research Relative to Tobacco Smoke Analytes Sub-Group CORESTA Recommended Method No. 74 DETERMINATION OF SELECTED CARBONYLS IN MAINSTREAM CIGARETTE SMOKE BY HPLC February

More information

Forensic Analysis of Blood Alcohol Concentration

Forensic Analysis of Blood Alcohol Concentration Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler

More information

CORESTA RECOMMENDED METHOD N 25

CORESTA RECOMMENDED METHOD N 25 CORESTA RECOMMENDED METHOD N 25 AMBIENT AIR FLOW AROUND CIGARETTES IN ROUTINE ANALYTICAL SMOKING MACHINES : CONTROL AND MONITORING (August 1991) 0. INTRODUCTION The development of smoking machines has

More information

using the Agilent 7696A Sample Prep

using the Agilent 7696A Sample Prep Automated Clean-up for Mineral Oil (Hydrocarbon Oil Index) Analysis using the Agilent 7696A Sample Prep WorkBench Application Note Automated Sample Preparation Authors Frank David, Karine Jacq, and Bart

More information

CORESTA Recommended Method No. 76

CORESTA Recommended Method No. 76 Cooperation Centre for Scientific Research Relative to Tobacco Tobacco and Tobacco Products Analytes Sub-Group CORESTA Recommended Method No. 76 DETERMINATION OF MOISTURE CONTENT (OVEN VOLATILES) OF TOBACCO

More information

ISO INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of individual and total sterols contents Gas chromatographic method

ISO INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of individual and total sterols contents Gas chromatographic method INTERNATIONAL STANDARD ISO 12228 First edition 1999-03-01 Animal and vegetable fats and oils Determination of individual and total sterols contents Gas chromatographic method Corps gras d'origines animale

More information

Lutein Esters from Tagetes Erecta

Lutein Esters from Tagetes Erecta Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Lutein Esters from Tagetes Erecta This monograph was also published in: Compendium

More information

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES Sandra Otte, Sonja Nowak & Michael Intorp Imperial Tobacco Group; Special Analytes Laboratory Hamburg,

More information

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017 Contribution To Develop Standards For The Global Vapour Industry Pierre-Marie GUITTON Next Generation Nicotine Delivery London - 14-15 June, 2017 Outline Introduction to CORESTA CORESTA activities Process

More information

Technical Report. E-Liquid Preliminary Proficiency Study

Technical Report. E-Liquid Preliminary Proficiency Study E-Cigarette Task Force Technical Report E-Liquid Preliminary Proficiency Study March 2015 Author: Rana Tayyarah Lorillard Tobacco Company Task Force Coordinator: Chuck Garner, Ph.D. R. J. Reynolds Tobacco

More information

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol 3-Acetyldeoxynivalenol 15-Acetyldeoxynivalenol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of trichothecene mycotoxin by gas chromatography [Feed Analysis Standards, Chapter

More information

DETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS

DETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS INTERNATIONAL OLIVE COUNCIL COI/T.20/Doc. No 32 November 2013 ENGLISH Original: ENGLISH Príncipe de Vergara, 154 28002 Madrid España Telef.: +34 915 903 638 Fax: +34 915 631 263 - e-mail: iooc@internationaloliveoil.org

More information

Should you have any questions, please contact Gerald Hsu, Ph.D., Senior Scientific Liaison ( or

Should you have any questions, please contact Gerald Hsu, Ph.D., Senior Scientific Liaison ( or Estradiol Transdermal System Type of Posting Revision Bulletin Posting Date 27 Jan 2017 Official Date 01 Feb 2017 Expert Committee Chemical Medicines Monographs 5 Reason for Revision Compliance In accordance

More information

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text. Estradiol Transdermal System Type of Posting Notice of Intent to Revise Posting Date 28 Sep 2018 Targeted Official Date To Be Determined, Revision Bulletin Expert Committee Chemical Medicines Monographs

More information

CORESTA Guide N o 18

CORESTA Guide N o 18 CORESTA Guide N o 18 November 2016 Technical Guide for Sample Handling and Sample Collection of E-Cigarettes and E-Vapour Generating Products E-Vapour Sub-Group 1. REVIEW AND HISTORY Issue Date Reason

More information

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column Application Note Food Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column Authors Ingrid Van Der Meer, Yun Zou, and Gustavo Serrano Agilent

More information

β-carotene-rich Extract From Dunaliella Salina

β-carotene-rich Extract From Dunaliella Salina 0 out of 5 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 β-carotene-rich Extract From Dunaliella Salina This monograph was

More information

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co.

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co. The Determination of Diacetyl and Acetylpropionyl in Aerosols from Electronic Smoking Devices using Gas Chromatography Triple Quad Mass Spectrometry S.C. Moldoveanu, A.G. Hudson, A. Harrison R.J. Reynolds

More information

Routine Analytical Chemistry Sub-Group Report Berlin 2016

Routine Analytical Chemistry Sub-Group Report Berlin 2016 Routine Analytical Chemistry Sub-Group Report Berlin 2016 Coordinator: Linda Crumpler, Cerulean Secretary: Colin Sinclair: JTI UK (until April 2016) Thomas Schmidt, Borgwaldt-KC 1. To develop CORESTA Recommended

More information

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids Headspace Gas Chromatography to Quantitate and 1.0 Purpose - This procedure specifies the required elements for calibration and use of the headspace gas chromatograph to determine alcohol (ethanol, methanol,

More information

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: of 9 Applicant: Address: ALD GROUP LIMITED ALD Building NO.2 Industrial 3rd Road, ShiXin Community, Shiyan Town, Bao An District, Shenzhen 5808, China.

More information

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds Application Note Food and Flavors Author Frank David Research Institute for

More information

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Analysis of short chain organic acids in tobacco and in some flavored e-liquids Analysis of short chain organic acids in tobacco and in some flavored e-liquids S.C. Moldoveanu, Karen B. Kilby, Amanda G. Hudson 1 Background Short chain organic acids from acetic to caprylic play an

More information

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method International Journal of Chemical and Pharmaceutical Sciences 2017, Mar., Vol. 8 (1) ISSN: 0976-9390 IJCPS Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by

More information

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China Date: Jan.17, 2018 Applicant Name: GD Sigelei Electroinc Tech Co., Ltd Applicant Add.: B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China Test sample(s) was(were)

More information

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note By: Roger Bardsley Introduction Analysis of biological fluids for volatile components by

More information

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,

More information

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is 2, 4, 5-T. 1. Instrument Liquid Chromatograph-tandem mass spectrometer (LC-MS/MS)

More information

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS. For in vitro use only. P81/V16/13.04.15 www.r-biopharm.com Contents Page Test Principle...3

More information

2014_TSRC77_Melton.pdf

2014_TSRC77_Melton.pdf Determination of Selected Flavour, Humectant and Plasticizer compounds in Tobacco, Tobacco Products, Electronic Cigarette Liquid and Electronic Cigarette Vapour by Gas Chromatography with Mass Selective

More information

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column Application Note Food Testing & Agriculture Authors Pat Sasso and Ken Lynam Agilent Technologies, Inc. Abstract

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes The Effect of Puff Profile and Volume on the Yields of E-Cigarettes Dr M J Taylor, Filtrona Technology Centre Smoke Science/Product Technology Meeting Seville, Spain, 29 September to 03 October 2013 Introduction

More information

Flupyradifurone. HPLC Method

Flupyradifurone. HPLC Method HPLC Method CIPAC Collaboration Trial according to CIPAC Information Sheet No 308 by Alexandra Michel Crop Science Division Bayer Aktiengesellschaft Alfred-Nobel-Str. 50, Building 6820 40789 Monheim am

More information

AppNote 1/2005. Blood Alcohol Analysis Using an Automated Static Headspace Method ABSTRACT

AppNote 1/2005. Blood Alcohol Analysis Using an Automated Static Headspace Method ABSTRACT AppNote 1/2005 Blood Alcohol Analysis Using an Automated Static Headspace Method Vanessa R. Kinton, Edward A. Pfannkoch, and Jacqueline A. Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum,

More information

Title Revision n date

Title Revision n date A. THIN LAYER CHROMATOGRAPHIC TECHNIQUE (TLC) 1. SCOPE The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate and triamcinolone acetonide

More information

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples Application Note Forensic Toxicology Authors Joe Crifasi Saint Louis University Forensic Toxicology Laboratory Saint Louis, MO, USA Ron

More information

STANDARD OPERATING PROTOCOL (SOP)

STANDARD OPERATING PROTOCOL (SOP) 1 STANDARD PERATING PRTCL (SP) Subject: Determination of Flavonol Glycosides in Ginkgo biloba Products by HPLC Analysis Project/Core No.: Core B Total 6 Pages SP No.: CB0104 Modified Date: 07/30/01 BTANICAL

More information

SUCROSE OLIGOESTERS TYPE I

SUCROSE OLIGOESTERS TYPE I SUCROSE OLIGOESTERS TYPE I Prepared at the 71 st JECFA (2009) and published in FAO JECFA Monographs 7 (2009). A group ADI of 0-30 mg/kg bw for this substance together with sucrose esters of fatty acids,

More information

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode Application Brief Biomedical Authors Melissa Churley Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa

More information

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2017, 9(9):70-80 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Development and Validation of Stability Indicating

More information

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph. Nitrofurantoin Capsules Type of Posting Revision Bulletin Posting Date 28 Dec 2018 Official Date 01 Jan 2019 Expert Committee Chemical Medicines Monographs 1 Reason for Revision Compliance In accordance

More information

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015) August 2015 Document for comment 1 2 3 4 5 CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA (AUGUST 2015) DRAFT FOR COMMENT 6 Should you have any comments

More information

The Analysis of Isotopically Labeled Propylene Glycol in ecigarettes

The Analysis of Isotopically Labeled Propylene Glycol in ecigarettes The Analysis of Isotopically Labeled Propylene Glycol in ecigarettes Raymond H. Farmen, Ph.D. The Coolest ecigarette Clinical Study Using Isotopically Labeled Propylene Glycol Raymond H. Farmen, Ph.D.

More information

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2

More information

Jagua (Genipin-Glycine) Blue (Tentative)

Jagua (Genipin-Glycine) Blue (Tentative) 0 out of 9 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 Jagua (Genipin-Glycine) Blue (Tentative) This monograph was also

More information

STANDARD OPERATING PROTOCOL (SOP)

STANDARD OPERATING PROTOCOL (SOP) 1 STANDARD PERATING PRTCL (SP) Subject: To determine the Contents of isoflavone in soybean products by HPLC Analysis Project/Core No.: Core B Total 9 Pages SP No.: CB0102 Modified Date: 05/15/01 BTANICAL

More information

2. is a set of principles intended to help sustain a habitable planet.

2. is a set of principles intended to help sustain a habitable planet. Chapter 2 Tools of the Trade 1 Multiple Choice 2-1 Safe, Ethical Handling of Chemicals and Waste 1. Which of the following statements are TRUE? I Organic solvents, concentrated acids, and concentrated

More information

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (11):236-242 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION OF SEMI-VOLATILE SOLVENTS IN THE PHARMACEUTICAL SUBSTANCE BOSENTAN

DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION OF SEMI-VOLATILE SOLVENTS IN THE PHARMACEUTICAL SUBSTANCE BOSENTAN Acta Poloniae Pharmaceutica ñ Drug Research, Vol. 71 No. 6 pp. 1107ñ1113, 2014 ISSN 0001-6837 Polish Pharmaceutical Society DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION

More information

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids Headspace Gas Chromatography to Quantitate and 1.0 Purpose - This procedure specifies the required elements for calibration and use of the headspace gas chromatograph to determine alcohol (ethanol, methanol,

More information

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench Application Note Authors Rima Juskelis and Jack Cappozzo Institute for Food Safety and Health

More information

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report Report No. : TCT170329C001 Date : Apr. 12, 2017 Page No.: 1 of 6 Applicant: Address: ALD GROUP LIMITED ALD Building NO.2 Industrial 3rd Road, ShiXin Community, Shiyan Town, Bao An District, Shenzhen 518108,

More information

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report Report No. : TCT171124C016 Date : Dec. 01, 2017 Page No.: 1 of 6 Applicant: Address: Shenzhen IJoy Technology Co., Ltd 3/F 13#Building,Hengmingzhu Tech. Industrial Park, Xiangxing Street, Shajing Town,

More information

E17 ETHYLCELLULOSE. Revision 3 Stage 4

E17 ETHYLCELLULOSE. Revision 3 Stage 4 00-205PDG.pdf 2 E7 ETHYLCELLULOSE Revision 3 Stage 4 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 9 20 2 22 23 24 25 26 27 28 29 30 3 32 33 34 35 36 37 DEFINITION Ethylcellulose is a partly O-ethylated cellulose. It

More information

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report Report No. : TCT170822C007 Date : Aug. 28, 2017 Page No.: 1 of 6 Applicant: Address: Shenzhen IJoy Technology Co.,Ltd 3/F 13#Building, Hengmingzhu Tech. Industrial Park, Xiangxing Street, Shajing Town,

More information

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Neosolaniol. [Methods listed in the Feed Analysis Standards] Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]

More information

CORESTA RECOMMENDED METHOD N 22

CORESTA RECOMMENDED METHOD N 22 CORESTA RECOMMENDED METHOD N 22 ROUTINE ANALYTICAL CIGARETTE-SMOKING MACHINE SPECIFICATIONS, DEFINITIONS AND STANDARD CONDITIONS (August 1991) 0. INTRODUCTION This CORESTA Recommended Method includes the

More information

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

EASI-EXTRACT BIOTIN Product Code: P82 / P82B EASI-EXTRACT BIOTIN Product Code: P82 / P82B Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS. For in vitro use only. AOAC Official First Action Method 2016.02 P82/V8/23.03.17 www.r-biopharm.com

More information

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Column Selection for the Analysis of Fatty Acid Methyl Esters Application Column Selection for the Analysis of Fatty Acid Methyl Esters Application Food Analysis Authors Frank David Research Institute for Chromatography President Kennedy Park B- Kortrijk, Belgium Pat Sandra

More information

Chromatographic Profiling as a Tool in the Comparison and Evaluation of Complex Mixtures

Chromatographic Profiling as a Tool in the Comparison and Evaluation of Complex Mixtures Chromatographic Profiling as a Tool in the Comparison and Evaluation of Complex Mixtures James C. Rogers*, Lisa S. Winkler, and Michael F. Borgerding R.J. Reynolds Tobacco Company, Research and Development,

More information

Analysis of (S)- and (R)-nicotine

Analysis of (S)- and (R)-nicotine Analysis of (S)- and (R)-nicotine in various nicotine samples and in e-liquids S. C. Moldoveanu*, G. M. Dull**, R. J. Oden*, W. A. Scott* *R.J. Reynolds Tobacco Co. **RAI Innovation Co. Background Nicotine

More information

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol. 3, No.2, pp 605-609, April-June 2011 RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem

More information

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE 1 out of 8 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE This monograph was also published in: Compendium of Food

More information

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS RESTRICTED INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS DRAFT FOR COMMENT Please address any comments you may have on this document, by 12 July 2006, to Dr S. Kopp, Quality Assurance and

More information

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

This revision also necessitates a change in the table numbering in the test for Organic Impurities. Methylphenidate Hydrochloride Extended-Release Tablets Type of Posting Notice of Intent to Revise Posting Date 27 Jul 2018 Targeted Official Date To Be Determined, Revision Bulletin Expert Committee Chemical

More information

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 643 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC METHOD APPROVALS Norvin Pharma Inc. Author Analytical Laboratory Approver Analytical Laboratory Group Leader Approver Manager Quality Control Chemistry

More information

Sucrose Esters of Fatty Acids

Sucrose Esters of Fatty Acids 0 out of 9 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 84th meeting 2017 Sucrose Esters of Fatty Acids This monograph was also published in:

More information

MONOGRAPHS (NF) Pharmacopeial Forum 616 HARMONIZATION Vol. 31(2) [Mar. Apr. 2005]

MONOGRAPHS (NF) Pharmacopeial Forum 616 HARMONIZATION Vol. 31(2) [Mar. Apr. 2005] 616 HARMONIZATION Vol. 31(2) [Mar. Apr. 2005] the recorder. The substances are eluted in the following order: o-toluenesulfonamide, p-toluenesulfonamide, and caffeine. The test is not valid unless the

More information

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report Report No. : TCT180129C014-1 Date : Feb. 09, 2018 Page No.: 1 of 6 Applicant: Address: Shenzhen Smoant Technology Co., Ltd 5/F, Block 16, Changxing Science Park, Wan'an Road, Shayi Community, Shajing Town,

More information

Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS

Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS INTERNATIONAL STANDARD ISO 19290 First edition 2016-12-01 Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS Cigarettes Dosage des nitrosamines

More information

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE WORLD JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES Ramalakshmi et al. SJIF Impact Factor 6.647 Volume 7, Issue 2, 1010-1018 Research Article ISSN 2278 4357 METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC

More information

Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures

Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures KENYA STANDARD KS 2177: 2017 Kenya Standard KS 2769-12:2018 Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures KEBS 2018 First Edition 2018

More information

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.5, No.4, pp 1736-1744, Oct-Dec 2013 Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin

More information

A comparison study of the analysis of volatile organic acids and fatty acids

A comparison study of the analysis of volatile organic acids and fatty acids Application Note Food Testing A comparison study of the analysis of volatile organic acids and fatty acids Using DB-FATWAX Ultra Inert and other WAX GC columns Author Yun Zou Agilent Technologies (Shanghai)

More information