PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

Size: px
Start display at page:

Download "PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes"

Transcription

1 Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of critical isobars Simplified, rapid cleanup procedures

2 Here to Support You with Your Clinical Research Personalized Support Your lab has its very own Technical Consultant that is available to assist with method development, optimization, troubleshooting, and product recommendations. Feel free to give them a call with any questions you may have! Get to Know Your Technical Consultant Take Advantage of Our Lab Our customers asked us for more support, we responded with PhenoLogix sm, a full-service analytical support laboratory. Let our PhenoLogix clinical research gurus save your lab time and money. Method development and optimization in our PhenoLogix laboratory On-site method development On-site hands-on training Explore PhenoLogix 24 Hour Access to Information Technical Database Access our vast database of technical notes, applications, webinars, and more. Search by industry, document type, and separation mode to easily find what you need. Tools Utilize our web tools to find product recommendations, create customized methods, and more. For Research Use Only. Not for use in diagnostic procedures. 214 Phenomenex, Inc. All rights reserved.

3 TABLE OF CONTENTS Simple Sample Preparation Solid Phase Extraction (SPE)...4- Protein Precipitation (PPT)...4- Full Pain Panel Screen Choose from 3 different core-shell stationary phases to customize your work Biphenyl, Greatest Versatility and Performance Phenyl-Hexyl, imethod Tested C18, General Purpose... 1 Analyze Individual Classes of Drugs Benzodiazepines Opiates Drugs of Abuse Ordering Information

4 Guaranteed Solutions Effective and highly reproducible methodology helps you ensure results and reduce costs. With guaranteed high quality products from Phenomenex, you can easily push your research to the next level. We guarantee that if Phenomenex products in this guide do not provide at least an equivalent separation as compared to other products of the same phase and dimensions, send in your comparative data within 4 days and keep the Phenomenex product for FREE! Solid Phase Extraction (SPE) Strata -X-Drug B Protein Precipitation (PPT) Impact Designed and quality controlled for basic drugs of abuse Time and solvent saving polymeric strong cation-exchange SPE sorbent No equilibration or condition steps needed Complete in plate removal of proteins (b-glucuronidase) Increase throughput 3x Leak-free oleophobic membrane Easily automated Part no. CE-766 HPLC/UHPLC Analysis Kinetex Biphenyl Core-Shell Technology Rugged and reliable core-shell columns Incredible performance and efficiencies TMS TMS Biphenyl Enhanced polar and basic retention Quality controlled for basic drugs of abuse 1.7 µm 2.6 µm µm 4

5 Rapid, Simple Cleanup for Pain Management Drugs and Drugs of Abuse Skip the method development, significantly reduce your sample preparation time, and save solvent using Strata -X-Drug B SPE tubes and 96-well plates. One method is all you will need to extract over 41 pain management drugs. Or easily upgrade the throughput of your existing protein precipitation methods with the new Impact Protein Precipitation long drip plates. Sample Pretreatment Acid Hydrolysis 1. To 2 ml urine sample, add µl concentrated hydrochloric acid. 2. Heat at 9 C for 2 hours. 3. Add 2 ml of 2 mm Sodium acetate buffer (ph 4.). 4. Add 1 ml of 6 N Potassium hydroxide (KOH). Vortex.. Centrifuge for -6 minutes at,-, rpm (2-22 C). 6. Verify ph of sample is between Load pretreated sample directly onto Strata-X-Drug B sorbent (see procedure below). Urine: Enzymatic Hydrolysis 1. Dilute µl urine with 1 µl buffer* and 2 µl of 1,, units/ml β-glucuronidase in a 96-well collection plate. 2. Vortex for -6 seconds. 3. Incubate in a water bath at 62 C for 3 minutes. 4. If performing SPE, transfer sample to a 96-well collection plate or autosampler vial, seal and centrifuge for 1 minutes at 2, rpm. Load supernatant onto Strata-X- Drug B sorbent (see procedure below.) If performing rapid removal of β-glucuronidase, load sample directly onto Impact Protein Precipitation plate (see procedure below). Serum / Plasma / Saliva: 1. Dilute plasma/serum 3:1 with 1 % Acetic acid. 2. Vortex. 3. Centrifuge for -6 minutes at 3,-3, rpm (2-22 C). 4. Load pretreated sample directly onto Strata-X- Drug B sorbent (see procedure below). *Buffer prepared by adding 8 ml deionized water and 111 ml glacial acetic acid to a 1 L volumetric flask, adjust final volume to the line with a % KOH solution and mix by inversion. For Ultra Clean and Concentrated Samples Strata-X-Drug B SPE Steps Procedure designed for 6 mg bed mass Strata-X-Drug B and can be adjusted for smaller or larger bed masses. Condition: Not required Equilibrate: Not required Load: Pretreated sample (see above for pretreatment recommendations) Wash: 2 ml of 1 mm Sodium acetate buffer (ph.) Wash 2: 2 ml Methanol Elute: 2 ml Ethyl acetate/isopropanol/ammonium hydroxide (ph.) (7:2:1) Evaporate: to dryness under a stream of Nitrogen at C Reconstitute: 1 ml 1 % Methanol Inject: μl Reduce solvent consumption; no conditioning or equilibration required! For Rapid Removal of Proteins (Ex. β-glucuronidase) Impact Protein Precipitation (PPT) Steps 1. Load 3 µl Acetonitrile to the wells of an Impact Plate 2. Load 1 µl hydrolyzed sample directly onto the Impact Plate 3. Vortex for 2 minutes at maximum possible speed 4. Apply vacuum at 2-7 inches Hg for 2-3 minutes and collect filtrate in a collection plate New long drip format now available! Part no. CE-766

6 Rapid, Reliable, and High Performance Pain Panel Testing Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell Biphenyl The new Kinetex Biphenyl ensures that your comprehensive screens display the needed performance with a ruggedness and reliability that will keep you at ease e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e 6.e 4.e 2.e. 2.2e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e 6.e 4.e 2.e e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e 6.e 4.e 2.e 2.6 µm x 2.1 mm 2 bar min 2.6 µm min µm App ID x 3. mm 16 bar App ID 2214 x 3. mm 1 bar App ID 2212 Conditions for all separations: Columns: Kinetex 2.6 µm Biphenyl ( x 2.1 mm) Kinetex 2.6 µm Biphenyl ( x 3. mm) Kinetex µm Biphenyl ( x 3. mm) Mobile Phase: A:.1 % Formic Acid in Water B:.1 % Formic Acid in Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Injection Volume: 1 µl Column Temperature: 4 C Detection: MS/MS (AB SCIEX API ) Samples: 1. Morphine 2. Oxymorphone 3. Hydromorphone 4. Amphetamine. Methamphetamine 6. MDA 7. Naloxone 8. Codeine 9. 6-MAM 1. Oxycodone 11. MDMA 12. Naltrexone 13. Hydrocodone 14. MDEA 1. Norfentanyl 16. Tramadol 17. Benzoylecgonine 18. Meprobamate 19. Normeperidine 2. Meperidine 21. Norbuprenorphine 22. Fentanyl 23. Buprenorphine 24. Flurazepam 2. PCP 26. Carisoprodol 27. Propoxyphene 28. Midazolam 29. Sufentanil 3. Norpropoxyphene 31. EDDP 32. Lorazepam 33. Methadone 34. Clonazepam 3. Oxazepam 36. Hydroxyalprazolam 37. Nordiazepam 38. Flunitrazepam 39. Temazepam 4. Alprazolam 41. Diazepam min

7 Go Even Faster! Using the high performance and versatility of the Kinetex 2.6 µm Biphenyl with a ballistic gradient allows you to cut down even more time from your cycles and significantly improve productivity. Imagine what you can do with this solution on your multiplex or dual-stream systems e6.e6 4.8e6 4.6e6 4.4e6 4.2e6 4.e6 3.8e6 3.6e6 3.4e6 3.2e6 3.e6 2.8e6 2.6e6 2.4e6 2.2e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e 6.e 4.e 2.e Kinetex 2.6 µm Biphenyl x 3. mm min App ID Conditions: Column: Kinetex 2.6 µm Biphenyl Dimensions: x 3. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic Acid in Water B:.1 % Formic Acid in Methanol Gradient: Time (min) % B Flow Rate:.7 ml/min Injection Volume: 1 µl Column Temperature: 4 C Detection: MS/MS (AB SCIEX API ) Analyte Q1 Q3 Retention Time (min) Morphine Oxymorphone Hydromorphone Amphetamine Naloxone Methamphetamine Codeine MDA Oxycodone Naltrexone Hydrocodone MDMA MDEA Norfentanyl Tramadol Benzoylecgonine Meperidine Meprobamate Norbuprenorphine Fentanyl Buprenorphine Flurazepam Analyte Q1 Q3 Retention Time (min) Carisoprodol PCP Propoxyphene Sufentanil MAM Midazolam Normeperidine EDDP Methadone Lorazepam Clonazepam Norpropoxyphene Oxazepam Hydroxyalprazolam Nordiazepam Flunitrazepam Temazepam Alprazolam Diazepam

8 41 Pain Management Drugs from Urine in Under. Minutes Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell Phenyl-Hexyl Achieve excellent resolution and separation of 41 pain management drugs using Kinetex core-shell Phenyl-Hexyl HPLC/UHPLC columns, a great choice for an alternative selectivity as compared to a C18. In addition to being a rapid separation, this method is also available as an imethod Application which allows AB SCIEX mass spec users to download the method and settings directly into their Cliquid software for instant method implementation. 4.6e6 4.2e6 3.8e6 3.4e6 3.e6 2.6e6 2.2e6 1.8e6 1.4e6 1.e6 6.e 2.e min App ID 2847 Column: Kinetex 2.6 µm Phenyl-Hexyl Dimensions: x 4.6 mm Part No.: B-449-E Guard: SecurityGuard ULTRA Phenyl-Hexyl Cartridges Part No.: AJ-8774 Mobile Phase: A: 1 mm Ammonium formate B:.1 % Formic Acid in Methanol Gradient: Time (min) % B 1 1 Flow Rate:.6 ml/min Injection Volume: 1 µl Column Temperature: 22 C Backpressure: 76.2 bar HPLC System: Agilent 126 Detection: MS/MS (AB SCIEX API ) 2.6 µm Skip the work and instantly run this method using the imethod Kit, a verified method that can be downloaded to your Cliquid software on your AB SCIEX mass spectrometer. imethod Kits contain MRM transitions, LC/MS/MS running conditions, sample preparation recommendations, and all of the consumables you will need to begin running samples. 8 Visit for more information

9 Analyte Q1 Q3 Retention Time (min) 6-MAM 1 (quantifier) MAM 2 (confirmation) Alprazolam Alprazolam Amphetamine Amphetamine Benzoylecgonine Benzoylecgonine Buprenorphine Buprenorphine Carisoprodol Carisoprodol Clonazepam Clonazepam Codeine Codeine Diazepam Diazepam EDDP EDDP Fentanyl Fentanyl Flunitrazepam Flunitrazepam Flurazepam Flurazepam Hydrocodone Hydrocodone Hydromorphone Hydromorphone Hydroxyalprazolam Hydroxyalprazolam Lorazepam Transition 1 for each analyte is used as the quantifier transition. Transition 2 for each analyte is used as the qualifier transition. Achieve Excellent Results, Every Time Recovery, Reproducibility, and Linearity of α-hydroxyalprazolam Concentration Precision Accuracy (ng/ml) (n = 3) Analyte Q1 Q3 Retention Time (min) Lorazepam MDA MDA MDEA MDEA MDMA MDMA Meperidine Meperidine Meprobamate Meprobamate Methadone Methadone Methamphetamine Methamphetamine Midazolam Midazolam Morphine Morphine Naloxone Naloxone Naltrexone Naltrexone Norbuprenorphine Norbuprenorphine Nordiazepam Nordiazepam Norfentanyl Norfentanyl Normeperidine Normeperidine Norpropoxyphene Norpropoxyphene Analyte area / IS Area Analyte Q1 Q3 Retention Time (min) Oxazepam Oxazepam Oxycodone Oxycodone Oxymorphone Oxymorphone PCP PCP Propoxyphene Propoxyphene Sufentanil Sufentanil Temazepam Temazepam Tramadol Tramadol MAM-d Amphetamine-d Benzoylecgonine-d Codeine-d Fentanyl-d Hydrocodone-d Hydromorphone-d Meperidine-d Methadone-d Methamphetamine-d Morphine-d Nordiazepam-d Normeperidine-d Norpropoxyphene-d PCP-d Recovery, 2. Reproducibility, and Linearity of Methamphetamine 1.. Concentration Precision Accuracy (ng/ml) (n = 3) 12 Analyte Conc./IS Conc Analyte area / IS Area Analyte area / IS Area Analyte Conc./IS Conc Analyte Conc./IS Conc

10 41 Pain Management Drugs from Urine in Under 4 Minutes Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell C18 Rapidly separate 41 pain management drugs, including critical isobars, using Kinetex core-shell C18 HPLC/UHPLC columns. 2.e6 1.9e6 1.8e6 1.7e6 1.6e6 1.e6 1.4e6 1.3e6 1.2e6 1.1e6 1.e6 9.e 8.e 7.e 6.e.e 4.e 3.e 2.e 1.e App ID 2689 Column: Dimensions: Part No.: Guard: Part No.: Kinetex 2.6 µm C18 x 3. mm B-4462-Y SecurityGuard ULTRA C18 Cartridges AJ-877 Mobile Phase: A: 1 mm Ammonium formate B:.1 % Formic Acid in Methanol Gradient: Time (min) % B 1 1 Flow Rate:. ml/min Injection Volume: 1 µl Column Temperature: 22 C Detection: MS/MS (AB SCIEX API 4 ) Analyte Q1 Q3 Oxymorphone Morphine Hydromorphone Amphetamine Methamphetamine Oxycodone MDA MDMA Codeine Naltrexone MDEA MAM Hydrocodone Benzoylecgonine Norfentanyl Tramadol Naloxone Normeperidine Meperidine Meprobamate PCP Norbuprenorphine EDDP Norpropoxyphene Clonazepam Flunitrazepam a-hydroxyalprazolam Carisoprodol Oxazepam Methadone Lorazepam Fentanyl Flurazepam Alprazolam Temazepam Propoxyphene Nordiazepam Diazepam Midazolam Sufentanil Buprenorphine Resolution of Critical Isobars Codeine/Hydrocodone 2.4e 2.e 1.e. 3.e 2.e 1.e. 1.e6 9.e 8.e 7.e 6.e.e 4.e 3.e 2.e 1.e min Morphine/Hydromorphone/Norhydrocodone min Oxymorphone/Dihydrocodeine/Noroxycodone Use our simplified SPE procedure on page 4 prior to HPLC/UHPLC analysis min 1

11 Benzodiazepines Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell Biphenyl Accurately and reliably analyze benzodiazepines using Kinetex Biphenyl HPLC /UHPLC. 7.e 6.e.e 4.e 3.e 2.e 1.e min App ID 2219 Column: Kinetex 2.6 µm Biphenyl Dimensions: x 3. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Injection Volume: 1 µl Column Temperature: 4 C Detection: MS/MS (AB SCIEX API ) Analyte Q1 Q3 Retention Time (min) Alprazolam 1 (quantifier) Alprazolam 2 (confirmation) Clonazepam Clonazepam Diazepam Diazepam Flunitrazepam Flunitrazepam Flurazepam Flurazepam Hydroxyalprazolam Hydroxyalprazolam Lorazepam Lorazepam Midazolam Midazolam Nordiazepam Nordiazepam Oxazepam Oxazepam Temazepam Temazepam

12 Opiates from Urine Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell Biphenyl Achieve resolution of critical isobars such as Morphine / Hydromorphone and Codeine / Hydrocodone using Kinetex core-shell Biphenyl HPLC / UHPLC columns. 2.e6 1.e min App ID 2218 Column: Kinetex 2.6 µm Biphenyl Dimensions: x 3. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Injection Volume: 1 µl Column Temperature: 4 C Detection: MS/MS (AB SCIEX API ) Analyte Q1 Q3 Retention Time (min) 6-MAM 1 (quantifier) MAM 2 (confirmation) Codeine Codeine EDDP EDDP Fentanyl Fentanyl Hydrocodone Hydrocodone Hydromorphone Hydromorphone Meperidine Meperidine Methadone Methadone Morphine Morphine Naloxone Naloxone Naltrexone Naltrexone Norfentanyl Norfentanyl Normeperidine Normeperidine Norpropoxyphene Norpropoxyphene Oxycodone Oxycodone Oxymorphone Oxymorphone Propoxyphene Propoxyphene Tramadol Tramadol

13 Miscellaneous Drugs of Abuse Detection Mode: LC/MS/MS Stationary Phase: Kinetex Core-Shell Biphenyl Separate various drugs of abuse including amphetamines, cocaine metabolites, and more. 1.2e6 1.e6 8.e 6.e 4.e 2.e min App ID 2211 Column: Kinetex 2.6 µm Biphenyl Dimensions: x 3. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Injection Volume: 1 µl Temperature: 4 C Detection: MS/MS (AB SCIEX API ) Analayte Q1 Q3 Retention Time (min) Amphetamine 1 (quantifier) Amphetamine 2 (confirmation) Benzoylecgonine Benzoylecgonine Carisoprodol Carisoprodol MDA MDA MDEA MDEA MDMA MDMA Meprobamate Meprobamate Methamphetamine Methamphetamine PCP PCP Sufentanil Sufentanil

14 Strata-X-Drug B SPE Finally, an SPE Sorbent for Drugs of Abuse Strata-X-Drug B is a polymeric strong cation-exchange SPE sorbent that is designed and quality controlled for basic drugs of abuse analysis. Save time and solvent; no conditioning or equilibrating required Achieve consistent, high recoveries; the sorbent is QC tested using drug probes from urine to ensure batch-to-batch reproducibility Reduce technician training requirements; use a single method to extract multiple drug classes Ordering Information Format Sorbent Mass Part Number Unit Price Tube 1 mg 8B-S128-AAK 1 ml (1/box) 3 mg 8B-S128-TAK 1 ml (1/box) 3 mg 8L-S128-TAK 1 ml (1/box) 3 mg 8B-S128-TBJ 3 ml (/box) 6 mg 8B-S128-UBJ 3 ml (/box) 6 mg 8B-S128-UCH 6 ml (3/box) 6 mg 8B-S128-UCL 6 ml (2/box) 96-Well Plate 1 mg 8E-S128-AGB 2 Plates/box 3 mg 8E-S128-TGB 2 Plates/box 6 mg 8E-S128-UGB 2 Plates/box Tab-less tube Accessories for Tubes Tabless Tube Holders Part No. Description Unit Price AH Well 1 ml Tabless Tube Holder for use with 96-well plate ea vacuum manifold (AH-89) AH-9 96-Well 1 ml Tabless Tube Holder for use with positive pressure manifolds ea Manifolds Part No. Description Unit Price AH-623 SPE 12-Position Vacuum Manifold Set, complete assembly ea AH-624 SPE 24-Position Vacuum Manifold Set, complete assembly ea Create a Customized SPE Method in Under 1 Minute Accessories for 96-Well Plates Manifold Part No. Description Unit Price AH Well Plate Manifold, Universal w/vacuum gauge ea Collection Plates (deep well, polypropylene) Part No. Description Unit Price AH Well Collection Plate, 3 µl/conical /pk AH Well Collection Plate, 1 ml/conical /pk AH Well Collectin Plate, 1 ml Round, 7 mm /pk AH Well Collection Plate, 2 ml Square/Round-Conical /pk AH Well Collection Plate, 2 ml Round/Round, 8 mm /pk Sealing Mats Part No. Description Unit Price AH-897 Sealing Mats, Pierceable, 96-Square Well, Silicone /pk AH-8631 Sealing Mats, Pierceable, 96-Round Well 7 mm, Silicone /pk AH-8633 Sealing Mats, Pierceable, 96-Round Well 8 mm, Silicone /pk AH-7362 Sealing Tape Pad 1/pk If Strata-X SPE products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 4 days and keep the Strata-X SPE product for FREE. 14 Phenomenex l WEB:

15 Ordering Information Core-Shell Technology μm Minibore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 2.1 x x x 2.1 3/pk Biphenyl A-4627-AN B-4627-AN D-4627-AN AJ-929 C18 A-461-AN B-461-AN D-461-AN F-461-AN AJ-8782 Phenyl-Hexyl B-463-AN D-463-AN AJ-8788 for 2.1 mm ID μm MidBore Columns (mm) SecurityGuard ULTRA Cartridges Phases x 3. 1 x 3. 1 x 3. 3/pk Biphenyl B-4627-Y D-4627-Y F-4627-Y AJ-928 C18 B-461-Y D-461-Y F-461-Y AJ-877 Phenyl-Hexyl B-463-Y D-463-Y AJ-8781 for 3. mm ID μm Analytical Columns (mm) SecurityGuard ULTRA Cartridges Phases x x x x 4.6 3/pk Biphenyl B-4627-E D-4627-E F-4627-E G-4627-E AJ-927 C18 B-461-E D-461-E F-461-E G-461-E AJ-8768 Phenyl-Hexyl B-463-E D-463-E F-463-E G-463-E AJ-8774 for 4.6 mm ID 2.6 μm Minibore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 2.1 x x x x 2.1 3/pk Biphenyl A-4622-AN B-4622-AN D-4622-AN F-4622-AN AJ-929 C18 A-4462-AN B-4462-AN C-4462-AN D-4462-AN F-4462-AN AJ-8782 Phenyl-Hexyl A-449-AN B-449-AN C-449-AN D-449-AN F-449-AN AJ-8788 for 2.1 mm ID 2.6 μm MidBore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 3. x 3. 7 x 3. 1 x 3. 1 x 3. 3/pk Biphenyl B-4622-Y D-4622-Y F-4622-Y AJ-928 C18 A-4462-Y B-4462-Y C-4462-Y D-4462-Y F-4462-Y AJ-877 Phenyl-Hexyl D-449-Y F-449-Y AJ-8781 for 3. mm ID 2.6 μm Analytical Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 4.6 x x x x 4.6 3/pk Biphenyl B-4622-E D-4622-E F-4622-E AJ-927 C18 A-4462-E B-4462-E C-4462-E D-4462-E F-4462-E AJ-8768 Phenyl-Hexyl B-449-E C-449-E D-449-E F-449-E AJ-8774 for 4.6 mm ID 1.7 μm Minibore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 2.1 x x x 2.1 3/pk Biphenyl B-4628-AN D-4628-AN F-4628-AN AJ-929 C18 A-447-AN B-447-AN D-447-AN F-447-AN AJ-8782 Phenyl-Hexyl B-4-AN D-4-AN F-4-AN AJ-8788 for 2.1 mm ID 1.7 μm MidBore Columns (mm) SecurityGuard ULTRA Cartridges Phases x 3. 1 x 3. 3/pk C18 B-447-Y D-447-Y AJ-877 for 3. mm ID 1.3 μm Minibore Columns (mm) Phases 3 x 2.1 x 2.1 C18 A-41-AN B-41-AN SecurityGuard ULTRA cartridges require holder, Part No.: AJ-9 If Phenomenex products in this brochure do not provide at least an equivalent separation as compared to other products of the same phase and dimensions, send in your comparative data within 4 days and keep the product for FREE. Phenomenex l WEB: 1

16 Access Clinical Research Guides, Applications, and More at Australia t: f: Austria t: f: Belgium t: (French) t: (Dutch) f: +31 () beinfo@phenomenex.com Canada t: (8) f: (31) info@phenomenex.com Denmark t: f: nordicinfo@phenomenex.com Finland t: f: nordicinfo@phenomenex.com France t: f: franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: f: indiainfo@phenomenex.com Ireland t: f: eireinfo@phenomenex.com Italy t: f: italiainfo@phenomenex.com Luxembourg t: +31 () f: +31 () nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: 81 2 f: nordicinfo@phenomenex.com Puerto Rico t: (8) 41-HPLC f: (31) info@phenomenex.com Sweden t: f: nordicinfo@phenomenex.com United Kingdom t: f: ukinfo@phenomenex.com United States t: (31) 212- f: (31) info@phenomenex.com All other countries: Corporate Office USA t: (31) 212- f: (31) info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR _I Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at Trademarks Kinetex is a registered trademark and Strata-X, Impact, MidBore, and SecurityGuard are trademarks of Phenomenex. Agilent is a registered trademark of Agilent Technologies, Inc. Cliquid is a registered trademark and API 4, API, and imethod are trademarks of AB SCIEX Pte. Ltd. AB SCIEX is being used under license. Disclaimers The products mentioned are not intended for clinical use. Because they are not intended for clinical use, no claim or representation is made or intended for their clinical use (including, but not limited to diagnostic, prognostic, therapeutic or blood banking). It is the user s responsibility to validate the performance of Phenomenex products for any particular use, since the performance characteristics are not established. Phenomenex products may be used in clinical diagnostic laboratory systems after the laboratory has validated their complete system as required by the Clinical Laboratory Improvements Amendments of 1988 (CLIA 88) regulation in the U.S. or equivalent in other countries. Strata-X is patented by Phenomenex. U.S. Patent No. 7,119, Phenomenex, Inc. All rights reserved.

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz and Laura Snow Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

Validation of an Automated Method to Remove

Validation of an Automated Method to Remove Shahana Wahab Huq 1, Richard Thomas 2, Agnes Cua 2, Seyed Sadjadi 1 1 Phenomenex, 411 Madrid Avenue, Torrance, CA 951 2 Precision Toxicology, 33 Bunker Hill Street, San Diego, CA 9219 Validation of an

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Strata -X Polymeric SPE

Strata -X Polymeric SPE Strata - Polymeric SPE Strata- Benefits of Strata- SPE vs. Traditional SPE Increase Detection Sensitivity by removing matrix contaminants Increase Column Lifetime by removing matrix contaminants Quality

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

E XCEL LENCE JUST GOT BETTER UCT FORENSICS CLEAN SCREEN XCEL SPE COLUMNS

E XCEL LENCE JUST GOT BETTER UCT FORENSICS CLEAN SCREEN XCEL SPE COLUMNS FORENSICS UCT E XCEL LENCE JUST GOT BETTER CLEAN SCREEN XCEL SPE COLUMNS CLEAN SCREEN XCEL COLUMNS EXTRACTION OF BASIC DRUGS AND METABOLITES FROM URINE/ BLOOD USING SPE CARTRIDGES 130mg Clean Screen Xcel

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching Liquid Chromatography Mass Spectrometry SSI-LCMS-8 LCMS-8 Drugs of Abuse: Analytes with Polarity Switching LCMS-8 Summary Seventy six analytes and their internal standards are described below. Multiple

More information

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Xiang He, 1 Casey Burrows 1, Matthew Noestheden 2, Michael Jarvis, 2 Adrian Taylor,

More information

Vitamin Testing APPLICATIONS GUIDE

Vitamin Testing APPLICATIONS GUIDE Vitamin Testing APPLICATIONS GUIDE Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

LC Application Note. Dangerous driver?

LC Application Note. Dangerous driver? LC Application Note Dangerous driver? www.palsystem.com Dangerous driver? Robert M. Sears 1 ; Kenneth C. Lewis 2 ; and Kim Gamble 3 1 SC Law Enforcement Division, Columbia, SC 29221; 2 OpAns LLC, Durham

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples

Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples Robert M. Sears, Toxicology Technical Leader 1, Kenneth

More information

1/27/ New Release, Quest Diagnostics Nichols Institute, Valencia

1/27/ New Release, Quest Diagnostics Nichols Institute, Valencia NEW TESTS Please Note: Not all test codes assigned to each assay are listed in the table of contents. Please refer to the complete listing on the page numbers indicated. Test Code Test Name Effective Date

More information

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK Overview Purpose:

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS A Comprehensive Method for the Analysis of Pain Management Drugs and Drugs of Abuse Incorporating Simplified, Rapid Mixed-Mode SPE with UPLC-MS/MS for Clinical Research Jonathan P. Danaceau, Scott Freeto,

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1 Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications dr. Jan Srbek, HPST Page 1 Major LC-MS Clinical Applications Steroids/Endocrinology Vitamin D Testosterone, Estradiol

More information

CLINICAL RESEARCH APPLICATIONS GUIDE

CLINICAL RESEARCH APPLICATIONS GUIDE CLINICAL RESEARCH APPLICATINS GUIDE More throughput Greater sensitivity Reduced costs Less downtime Your job has never demanded more from you. Doctors need accurate results yesterday. You need to minimize

More information

Oral Fluid Drugs of Abuse Testing

Oral Fluid Drugs of Abuse Testing Solutions at Work Oral Fluid Drugs of Abuse Testing Volume indicator turns blue when collection is complete (average 3 minutes) Non-invasive collection test anytime, anywhere Directly observed, no gender

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS UCT Part Numbers CSXCE106 Clean Screen XCEL I 130mg / 6mL SPE Cartridge SPHACE5001-5 Select

More information

Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS

Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS UCT Part Numbers XRDAH203 Gravity Flow XtrackT DAU 200 mg, 3 ml column SPHPHO6001-5 Select ph Buffer

More information

Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler

Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler Fred D. Foster 1, John R. Stuff 1, Jacqueline A. Whitecavage 1, Edward A. Pfannkoch 1, Mark

More information

Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1.

Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1. Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1.0 Software Xiang He 1, Adrian M. Taylor 2, Michael Jarvis 2 and Alexandre Wang

More information

UCT STYRE SCREEN INNOVATION THROUGH CHEMISTRY

UCT STYRE SCREEN INNOVATION THROUGH CHEMISTRY UCT STYRE SCREEN PO L Y M E R I C S O R B E N T S P E INNOVATION THROUGH CHEMISTRY STYRE SCREEN STYRE SCREEN Extraction Columns Styre Screen extraction sorbents are formulated with an ultra clean, highly

More information

Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab

Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab Application Note Clinical Research Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab Authors Adam Barker 1,2, Frederick G. Strathmann 3, Natalie N. Rasmussen 4, and Carrie

More information

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens This document describes the validation of a Neogen Fentanyl kit for the semi-quantitative analysis of

More information

Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids

Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids PO-CON1753E Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids ASMS 2017 TP-442 Joshua F. Emory 1, Nathan DeFreitas 2, Michael Roberts 1, Manoj Tyagi 2, M.

More information

Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population

Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population Adam S. Ptolemy 1, Colleen Murray 2, Edward Dunn 3,

More information

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine PO-CON737E A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine ASMS 7 WP 353 Shao Hua Chia ; Zhi Wei Edwin Ting ; Daisuke Kawakami

More information

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Speaker: Sky Countryman, Manager of PhenoLogix and Applied Technologies, Phenomenex Webinar Host:

More information

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity Selectivity Accelerated Stationary Phase: Biphenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor Biphenyl Column With Raptor

More information

CLINICAL RESEARCH APPLICATIONS GUIDE

CLINICAL RESEARCH APPLICATIONS GUIDE CLINICAL RESEARC APPLICATINS GUIDE Your job has never demanded more from you. Doctors need accurate results yesterday. You need to minimize costs while increasing the number of samples run. New tests require

More information

Alcohol Biomarkers by UHPLC-MS/MS

Alcohol Biomarkers by UHPLC-MS/MS Alcohol Biomarkers by UHPLC-MS/MS Application #AN9 ACE Excel. C8 x. mm EXL--U A: mm ammonium fluoride B: MeCN....... ml/ µl C AB SCIEX triple quad Negative ESI MRM Source temperature: C IonSpray voltage:

More information

Modernizing the Forensic Lab with LC-MS/MS Technology

Modernizing the Forensic Lab with LC-MS/MS Technology Modernizing the Lab with LC-MS/MS Technology Innovative SCIEX Analytical Tools for the Rapid Identification of Drugs of Abuse in Samples Oscar G. Cabrices 1, Holly McCall 1, Xiang He 1, Alexandre Wang

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Valérie Thibert 1, Norbert Dirsch 2, Johannes Engl 2, Martin Knirsch 2 1 Thermo Fisher Scientific,

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

Powerful Sample Prep and LC Column Solutions for Forensic Toxicology Applications

Powerful Sample Prep and LC Column Solutions for Forensic Toxicology Applications Thank you for joining us! Our session will begin shortly Powerful Sample Prep and LC Column Solutions for Forensic Toxicology Applications While you are waiting, please feel free to browse our library

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years Drug Adherence Assessment Report CleanAssure TM (DRIED BLOOD SPOT): Detection Range see NOTES. Prescribed Medications: NO MEDICATION LIST PROVIDED CONSISTENT RESULTS - MEDICATION DETECTED (PARENT DRUG

More information

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup Application Note Forensic Testing Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup Author Limian Zhao Agilent Technologies, Inc.

More information

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS Julie Cichelli, PhD Agilent Technologies Application Engineer April 29, 2014 Agenda A method for the rapid analysis

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation,

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

Evaluation of the Impact of Expanding ELISA Screening in DUID Investigations. Aileen Lu*, Karen S. Scott, Aya Chan-Hosokawa, and Barry K.

Evaluation of the Impact of Expanding ELISA Screening in DUID Investigations. Aileen Lu*, Karen S. Scott, Aya Chan-Hosokawa, and Barry K. Evaluation of the Impact of Expanding ELISA Screening in DUID Investigations Aileen Lu*, Karen S. Scott, Aya Chan-Hosokawa, and Barry K. Logan FSF Emerging Forensic Scientist Award Oral Presentation Disclosure

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,

More information

There's a Cleaner Way!

There's a Cleaner Way! Using Liquid-Liquid Extraction (LLE)? There's a Cleaner Way! LLE Liquid-Liquid Extraction START SPE Solid Phase Extraction SLE Supported Liquid Extraction STOP STOP Cleanest Cleaner www.phenomenex.com/replacelle

More information

Rapid Hydrolysis of Benzodiazepines in Urine. Alicia Zook 1 and Crystal Xander B.S. 2. Cedar Crest College, Allentown, PA 1

Rapid Hydrolysis of Benzodiazepines in Urine. Alicia Zook 1 and Crystal Xander B.S. 2. Cedar Crest College, Allentown, PA 1 Rapid Hydrolysis of Benzodiazepines in Urine Alicia Zook 1 and Crystal Xander B.S. 2 Cedar Crest College, Allentown, PA 1 Health Network Laboratories, Allentown, PA 2 Abstract: Benzodiazepines are sedative/hypnotic

More information

September HCMC Toxicology Transition: Additional information and Frequently Asked Questions

September HCMC Toxicology Transition: Additional information and Frequently Asked Questions September 2016 HCMC Toxicology Transition: Additional information and Frequently Asked Questions Many clinicians have asked for more information about the Urine Drug Compliance Analysis (LAB8742) switch

More information

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis A Fast and Sensitive LC/MS/MS Method for the Quantification and Confirmation of 3 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine Samples Cliquid Software for Routine LC/MS/MS Analysis

More information

The Drug Testing Process. Employer or Practice

The Drug Testing Process. Employer or Practice Disclosures Clinical Professor, Jefferson Medical College BOD MROCC [Medical Review Officer Certification Council] BOD National Sleep Foundation BOD POEMS [Pennsylvania Occupational & Environmental Medicine

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

BETA-GLUCURONIDASE PRODUCT LINE INNOVATION THROUGH CHEMISTRY. FORENSICS

BETA-GLUCURONIDASE PRODUCT LINE INNOVATION THROUGH CHEMISTRY.   FORENSICS FORENSICS BETA-GLUCURONIDASE PROD LINE INNOVATION THROUGH CHEMISTRY ABALONASE Purified Beta-Glucuronidase Formula Clean, Rapid And Reliable Shown from left to right: Abalonase purified Beta-glucuronidase

More information

Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform

Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform Fredrick D. Foster, John R. Stuff, Jacqueline Whitecavage GERSTEL, Inc., 701

More information

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D Director: David J.

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D Director: David J. Drug Adherence Assessment Report Prescribed Medications: NO MEDICATION LIST PROVIDED CONSISTENT RESULTS - REPORTED MEDICATION DETECTED (PARENT DRUG AND/OR METABOLITE) REPORTED PRESCRIPTION FLAG ANTICIPATED

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information